Loading...
HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 3 LT 13__%MUNICIPALITY OF ANCHORAGE~. ,He[ ~h and Environmenhal Prote; ]ion Fourth Floor West 825 L Street Anchorage, Alaska 99501 279-2511, x 224, 225 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: DISTANCE FROM WELL_L~O~/~'_ INSIDE LENGTH ____ __  NUMBER OF MANUFACTURER .... MATERIAL ............... COMPARTMENTS INSIDE WlD1 H ..... LIQUH) DEPTH ........ LIQUID CAPACITY /<:~:)_ GALLONS. TILE DRAIN FIELD: DISTANCE FROM WELL~¢ Fi'/. FOUNDATION_ DISTANCE BETWEEN LINES ...... TRENCH WIDTH~ IN. ABSORPTION AREA ~0 DEPTH: TOP OF TILE ]0 FINISH GRADE TOTAL LENGTH NEAREST LOT LINE ......... OF LINE TOTAL EFFECTIVE SQ. FT. LENGTH OF EACH LINE DEPTII OF FILTER MATERIAL BENEATH TILE _ ~. ABOVE TILE/~- IN. SEEPAGE PIT: Log Crib BUILDING FOUNDATION__ DIAMETER OR WIDTh~ LENGTH__, .DEPTH Rings/CRIB SIZE: DIAMETER .... DEPTH DISTANCE FROM: WELL. __. TOTAL EFFECTIVE NEAREST LOT LINE _ . ABSORPTION AREA (WALL AREA) .SQ. F'F. Well Class:~0m~ Depth: Well Distance To: Lot Line Bldg: Sewer Line: Pipe Materials: # of Bedrooms: Installer: ~%['[[ Remarks: DATE"~ "'~'¢'"")'~A P P R 0 V E D TiI-1 3-21-77 0.0~ LOT 1 SANDY SILT W/SOME GRAVEL 3.O' SANDY SILT W/TP~ACE GRAVEL Brown, Slightly Moist, Medium Dense Test hole locations are approximate and have not been located by survey methods. 19.0'TD Water Table Not Encountered This log represents subsurface soil conditions within Lot 13, Block 3, Valli-Vue Estates, No.' 2 SE¼, Section 14, T12N, R3W, S.M., Anchorage, Alaska Lc__ .[__ NS SANITARY SEWER TEST HOLE TOTEM REALTY A~CIIORAGE ~ ALAS ICA KS¸ March 23, 1977 R & M NO. 751129 Mr. Robert Bear Totem Realty 724 E. 15th Anchorage, Alaska 99501 Test Hole and Soil Log Report for Sanitary System Lot 13, Block 3, Valli-Vue Estates No. 2, SW¼, Section 14, T12N, R3W, S.M., Anchorage, Alaska Dear Mr. Bear: We are submitting herewith the ~test boring results and our conm~ents regarding soil conditions encountered at the subject site. This in- v~a~igation was performed in accordance with your request of March 21, 1977 and those procedures outlined in a letter dated July 15, 1975, by ~tr. Rolf Strickland of the Municipality of Anchorage, Department of Environmental Quality. A single test hole was put down within the subject site area for the purpose of defining genera], subsurface soil conditions for the proposed sanitary system. Excavation was accomplished with an auger type drilling rig and the test hole was extended to a total depth of 19 feet below ground surface. The final log prepared for the test hole has been included in Drawing A-01. Groundwater was not encountered in the test hole while drilling. A percolation test was attempted in order to determine the percolation rate of the sandy silt encountered throughout the depth of the test hole. It was found, though, that after pouring approximately ].50 gallons of water into the test hole, the water was percolating into the soil at the same rate that it was being added (approximately 6-8 gallons per minute). This suggests that there may be a permeable layer of well graded sands and gravels near the bottom of %he test hole which was not detected during drilling. Because of the conflict between the percolation rate observed and the expected percolation rate of the soils encouhtered, it is recommended that a qualified geotechnical engineer be at the subject site when the leaching field is being excavated in order to determine the most suitable depth for leaching pipe burial. Mr. Robert Bear Page -2- March 23~ 1977 We appreciate being given this opportunity to be of service to you. Should you have any questions with regard to the above~ please do not hesitate to contact us. Very truly yoursr R & M CONSULTANTS, INC. Staff Geologist J~/pe xc: Municipality of Anchorage GREATER ANCtlORAGE AREA BOROUG:, Department of Environmental Quality 3330 "C" Street Anchorage, Alaska 99503 SOILS LOG - PEROI,A~I'ION TEST Legal Descri P~}I~Z~~C_ This form reports: soils Iog_~ v Percolation test Depth Feet 2- 3- 5- 6- 7- 8- 10- 11 - 12- 13- Was ground water encountered? If yes, at what depth? Reading Date Gross Time Net Time Depth to Water Net Drop Percolation rate m~nute. -Proposed installation: Seepage Pit Drain Field Depth of Inlet ............ · Deptl~--~6-~%~t%~--O¥-i)it or trench COMMENTS: EO 040 (6/74) Date: ~' "~qTER ANCHORAGE AREA BOROUGH : ~ ~,%~.; .~ment of Environmental Quality ~-- 3330 "C" Street Anchorage, Alaska 99503 Performed for <~-~ ~~ . Date performed Leg. al Descript~n: Z~ ~'~ ~ ~ ~ L)~ ~-9~-I-~ Th~s form reports: Soils log ~L · Percolation test Depth Feet 1 2- 3- 4- 5- 6- 7- 8- 9- l0 - ll - 12 - 13 - Was ground water encountered? If yes, at what depth? Reading Date I Gross Time ' Net Time Depth to H2O Net Drop Percolation r~te minute, Proposed installatiop: Seepage.Pit " Drain Field Depth of Inlet Depth to bottom of pit or trench COMMENTS: Performed By: ~ ~ Certified By: .. Date: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P,O. Box ;196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D, # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING C)l~'~[-~-C:)''~ NAA# ~1 ~'),'~-"~'~--~ GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner Mailing address Day phone Lending agency Mailing address Agent Address Day phone R-70- 2--7 { 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Un/ess otherwise requested, HAA will be held for pickup. NOTE: Individual well Community well Public water If community weft system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: NOTE: Individual on-site Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. So S'I'ATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage flies and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. NameofFirm I ~Jolo-~ ow~.~.~ '~,,¢ Phone c~'~~/~' Address ¢0-_% U¢./' /~-~ ~ ~.c~-~ /~.¢_~ , ~ EngineeCs signature '~ ~~ Date bedrooms. DHHS SIGNATURE Approved for 'T' ~-/~:~ E E Disapproved. Conditional approval for bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health ~nd Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional enginder's work. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Health Authority Approval Checklist LegalDescription: ~/'~.~,' '~J~-,~- £~l~2- t"5~. ParcelI.D.: (~e~- ,.~/- 2-0 A. WELL DATA Well type If A, B, or C, attach ADEC letter. ADEC water system number Log present(Y/N) Date completed Total depth Cased to Casing height (above ground) Sanitary seal (Y/N) Wires properly protected (Y/N) FROM WELL LOG AT INSPECTION Date of test Static water level Well production g.p.m, g.p.m. WATER SAMPLE RESULTS: Coliform Nitrate Other bacteria Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Date installed 7//~?/77 Tank size Foundation cleanout (Y/N) '%/ Depression (Y/N) Date of Pumping '-~..,v~.. I(~o°" Pumper ~ '[' C. ABSORPTION FIELD DATA Date installed 7/'~q/7 7 Length ~ ~ ! Width 5 ~ Effect ye absorption area. ~, ~ 0 Date of adequacy test ~'~'(/~ ~d Fluid depth in absorption field before test (in.); ~,~' Fluid depth ~ (ins) Minutes later: Peroxide treatment (past 12 months) (Y/N) Number of Compartments ~' Cleanouts (Y/N) ~' High water alarm (Y/N) t'~/ Soil rating (g.p.d./fF or fF/bdrm) /'~) Gravel thickness below pipe Monitoring Tube present (Y/N) ~ Results (Pass/Fail) ~ System type ~ O Total depth I ~ · Depression over f e d (Y/N). For '~ bedrooms Immediately after ~OOgal. water added (in.): Absorption rate = ~' J~'~) g.p.d. If yes, give date 72-026 (Rev. 3/96)* D. LIFT STATION ~'7~,11 Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/llolding tank on lot Absorption field on lot Public sewer main Sewer/septic service line Size in gallons "Pump on" level at* *Datum "Pump off" level at* On adjacent lots On adjacent lots Public sewer manhole/cleanout Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation "-/ Properly line ~' /o Absorption field ~ Water main/service line /%/~ Surface water/drainage. J'J,/O Wells on adjacent lots ~'/~\ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Properly line .)/~'~ Sudace water Curtain drain Building foundation ~ !~ Water main/service line ~ ,~L.~; Driveway, parking/vehicle storage area Wells on adjacent lots ENGINEER'S CERTIFICATION I certify that I have determined thru field inspections and review of Municipal reco~db t'h,~'t t'h~'abbve systems are in conformance with MOA HAA guidelines in effect on this date. Signature '~' Engineer's Name HAA Fee $ Date of Payment Race,pt Number 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number ~,MUNICIPAL~TY OF ANCHO:.h~GE~'~ DEPARTME~X~..-· OF HEALTH AND ENVIRONMENT, f PROTECTION 825 L Skreet Ancno~aa .. Alaska 99501 264-4720 Date Received: ~r~,~-e~- ~t~--[~l. lq]] -- Time _~m~__ ~!2: Time #3: Time Date LLm~q~ Date Date REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES Property Owner: Main g Address: 4: Single Family Residence: N) Number of Bedrooms: __(i!hSA,~_ -- Multiple Family Residence: ( ) Number of Bedrooms: o Well System: Individual_ well ( ) Community/Public System ~) Permit # Depth of Well Well Log on File Sewage Disposal System: Permit ~ Jll[~ Installed Septic Tank Size _~O Absorption Area ~ Soils On-site System ~) Public Utility ( ) Manufacturer ~ Rate ~O Material/~~ 7. Distances: Well to Septic Tank to Absorption Area to Sewer Line Nearest Lot line Absorption Area to Nearest Lot Line Page r~wo Department of Health and Environmental Prohechion Request for A[?proval of Individual Sewer and Water Facilit;Les Affadavit Attached: ( ) Approved: ~~~ Disapproved: Letter Attached: ( ) Date: Department Worksheet: Municipality of Anchorage DEPARTMENT OF HEALTH & ENVIRONMENTAL PROIECTION POUCH 6-650 ANCHORAGE, ALASKA 99502 279-2511 .E.UEST EON APPROVAE OF ,NO,.,OUA SE.E. AN5 WATE. EAC,L.T.ES REcgIV 1. TYPE OF LOAN 12, ASSESSORS PARCEL NUMBER [] VA [] F,H,A. ~ CONV [] I 3. LENDING INSTITUTION 4. REALTOR ONAGENT ~?:,:~ First National Bank of Anchorage ~,Ar:i: Bonnie Mehner ~,~"~ ',~: P. O. BoX 4-2090 A;~cqI;~;s Realty Center Anchorage, glaska 99509 2060 W. DSraond Blvd. Anc}~rage 5. SELLER 6. BUYER :~'~;~'L~ Lutjo-T~rtborlS~-~e Cona'~2_cuctJ_on ;q:;~7~ Bri~m L. & .lY',x:Trg~et S. Pose ,~?:~ ,-:,~,z; Box 31 L '~h; g~; 4933 Wesleyan Drive gnchorage, Ak 99507 ~chorage, g_laska 99504 7, LEOAL BESCNIPTION 8. LOCATION/STREETABBRESS Lot 13, Block 3, Valli ~e ~2 Subdvision N/4~I Lonetree Circle (off of O'Malley) ~. TYPE 0F DWELLING ~B. WATER SUPPLY It SEWAGE BISPOSALSYSTEM ~ SINGLE FAMILY RESIBENCE 3 BDRMS ~] PUBLIC gTlblly-cor~f~Ility [] PUBLIC UTILITY [] MULTI-FAMILY RESIBENCE__ RGRMS [] PRIVATE 0N~SITE ~ 0N-SITE YEAR INSTALLED INSTRUCTIONS TO REQUESTOR 1. Complete Items 1 to 11 above 3. Send to address above 5. Response will be returned to lending 2. Remove the carbon 4. Please allow 10 days for processing institution DATE RECEIVED DATE OF INSPECTION TIME OF INSPECTION INSPECTOR TYPE DEPTH YEAR DRILLED PERMIT REFERENCE LU ~ CONSTRUCTION BACTERIAL ANALYSIS LAB REFERENCE NO. YEAR INSTALLED INSTALLER TANK SIZE MANUFACTURER ~ DIMENSIONS CRIB CONSTRUCTION ~- [] PIT ~ TOTAL LINE LENGTH TRENCH DEPTH GRAVEL DEPTH ~ [] DISPOSAL LU FIELD ~ FT. FT. FT. TOTAL ABSORPTrON AREA PERMIT REFERENCE SQ. FT. 72 010 (11/76)