HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 3 LT 28LL 0 IE - - 4o LoT' GRE/'". R ANCHORAGE AREA BOR?IGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME LOCATION ~:~-~ 7'-'~ 0..,~¢~¢.L~ LEGAL DESCRIPTION SEPTIC TANK: DISTANCE FROM WELL INSIDE LENGTH MANUFACTURER INSIDE WIDTH NUMBER OF MATERIAL ,,,~/,/~%'~:-~g,'¢~' COMPARTMENTS / LIQUID DEPTH LIQUID CAPACITY/~"~ GALLONS. TILE DRAIN FAELD:- TOTAL LENGTH DISTANCE FROM WELL ~ FOUNDATION ¢ /¢- NEAREST LOT LINE_ ~:~ ! OF LINES ~ ?"-~' / NUMBER OF LINES / DISTANCE BETWEEN LINES ~ ,~ TRENCH WIDTH-- IN. TOTAL EFFECTIVE ~"'ABSORPTION AREA ~ 0 ~ 0 SQ. FT. LENGTH OF EACH LINE /('~ ~ 7. ~" ! i DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE '"~/~'/--L/IMATERIALBENEATH ~' (~ ~ TILE ~1t. ABOVE TILE (/~ IN. WELL: TYPE CONSTRUCTION BUILDING NEAREST FOUNDATION LOT LINE __ DEPTH_ DISTANCE FROM: NEAREST SEPTIC SEEPAGE SEWER LINE TANK__ SYSTEM ~'OQ~ i ~J' CESSPOOL OTHER SOURCES APPROVED I/ DISAPPROVED REMARKS DISTANCES: INSTALLED BY: SEWER LINE DEPTH: PIPE MATERIAL: ~GT ~_ LOT SLOPE: REMARKS: DIAGRAM OF SYSTEM Form LQ-032 Gte/ :r ANCHORAGE AREA BOF'--~UGH DEPARTMENT OF ENVIRONMENTAL QUALITY P~R M IT NO. SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT INSTALLATION OF: SEPTIC TANK TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SO,L TEST .ES'LT SEEPAGE PIT TO BE INSTALLED BY L/ NOTE= THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. O, 2'/ SEPT,OTANKS'ZE I'"L60 TYPE FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT DRAIN FIELD SEEPAGE AREA SIZE DIAGRAM OF SYSTEM SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK . SEEPAGE PIT . TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC T~NK DRAIN FIELD --/ _~ SEPTIC TANK* .. SEEPAGE PIT TO RIVER. LAKE. STREAM. SEEPAGE PIT ALSO CONSIDER AREA WELLS. SEEPAGE Pit CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP EXCAVATION 5 FEET INTO UNDiSTURBeD SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEl. BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. E I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. Test Hole 8 Lot 28, Block D~pth in Feet From 0.0' 6.0' To 6.0' 10.0' 10.0' 16.5' Elevation: Existing Ground W.O. #17378 Soil Description F-4, Sandy Silt, ML, tan, %~et, Grou~ B. N~S, Gravelly Sand, SW-SP, gray, damp, Group E. F-2, Silty Gravelly Sand, SM, tan, damp, some cobbles from 11' to 13.5', Group C. Bottom of Test Hole: Frost Line: Free Water Level: 16.5' None None Type of ~ample pepth M~ Sample Group · '~:-t~?~ $. '~4.0'- 4.5' Wet G B 2 9.0'-10.0' Damp G E 3 15.0'-16.5' Damp G C Remarks: 1=. Type of sample, G = Grab. 2, Group refers to similar material, this study only.