Loading...
HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 4 LT 31· Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number:-~"~L*-~ c~ ~D,C> ~' ~ PID Number: 0 N~me: ~ Upgrade ~ ~ ~oo~c~ Wastewater System: ~ New Address: ~[ ~~.~,~ ABSORPTION FIELD Phone: ~ ~ ~ -- ~ J Ne. of B~rooms: ~ Deep Trench ~ Shallow Trench ~ Bed ~ Mound ~ Other Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION ~' .~,.~,~ ~, ~ ~/sq. ~t. Lot: Block: Subdiv~[~ Depth to pipe bo~om from original grade: Gravel depth beneath pipe Township: IRange: JSectio,= Fd] added above original grade: Gravel length: , ~' WELL: D New ~ ~ ~ ~ Clsssification (Private, A,B.C): . .~ _ ~1 Depth: Cased TO: Total absorption ares; Pipe material: ~,~~ Date Drilled: StaticWater Level:Ft. Insta~ ~0~ ~'~ Dateinstal~d: /~ From Tank Field Station Tank Sewer Lines ~ ~ M ~ ~ [L Wel~ ~ ~ Material: Number of Compa~ments: Sudace Water 1~3~ Iot~ ~ -- i~* LIFT STATION LineL°t ~' 4,~ -- , % ~ Size in ga,,ons: JManufacturer: ~ "Pump on" level at: ~at ~ High water alarm at: I Remarks: ~ tow L{.M ~ ~to~~ BENCH MARK of Health and Human Se.ices approval Department Reviewed and approved by: ~~. ~ Date: ~ '~- ~ 79-013 (Rev. 9/91) MOA 25 PERMIT ND, SWDBO096 EXIST. SEPTIC DN LOT 32 I~ LOCATE~ I c3 'k LINE C~\Work\31-4VVUE,DWG AS-BUILT WASTEWATER ABSORPTION LOT 31, BLOCK 4 VALLI SYSTEM A P,I,D, ND, 015-32-234 3a EF. IN FAILURE NEW 1,250 G ~:EPTIC TANK C,D, A B C FC 19.7 T1 19.6 T8 18,0 45.3 DC 46.9 C1 5%4 22,9 44,1 75,2 27.9 45,4 8%1 M2 27,7 20,1 C3 45,3 19.9 VALI VUE IS SEARVED BY A COMMUNITY WELL & ~I~T, SYSTEM. ND WELLg WITHIN 200' OF PROPDSE~ INSTALLATION, EXISTING ~EPTIC SYSTEM ARE GREATER THAN 50 FEET AWAY FROM THE PROPO~EO ~Y~TEM, SEPTIC ON LOT 30 IS LOCATE~ IN THE SW CORNER DF THE LOT, DESIGN, Pert R~'tm 16 MIn/Inch Soil RoA;Ing, 0,6 gpd/sF 4 B,Ri iO00,$F Required AS-BUILT Deep Trench 6,' EF?ec-blve,~ 3' Wide, 9' To'to& ])epf:h, 83' Lorig 1000 SF To'roi PREPARED FOR~ Mr, Rober~ 3roulllette 6221 West Tree Drive Anchorage, AK 99516 (907> 346-2288 PANNDNE ENG, SVC P, 0, BOX 142025 ANCHORAGE, ALAgKA 99514 878-8818 ~ATI~Z-~L-m-~-g~ I A~-BUILT ISCALE~ 1'=30' / AS-BUILT DETAILS WASTEWATER A)~SORPTIDN SYSTEM LOT 31, BLOCK ~ VALLI VUE P.I.]]. ND, 015-32-234 z w '.'fi:::::::::::::::: : ::1:-5-~--7-~ :'T%:-'" ~Steven R. Pannone~ C,\Work\31-4VVUE,DWG PREPARED FOR: Mr, Rober~ Brouillette 6221 West Tree Drive Anchorage, AK 99516 (907) 346-8288 PANNDNE ENG, SVC, P, O, BOX'142025 ANCHORAGE, ALASKA 99514 274-0308,'872-8218 FAX DATEI 6-8-98 NOT TD SCALE AS-BUILT PAGE 1 OF 1 MUNICIP3%LITY OF ANCHORAGE DEP~RTMENT OF HE~-LTH~-ND ~ SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERi, IT PERMIT NUMBER:SW980096 DESIGN ENGINEER:STEVEN R. PD/~NONE OWNER NAME:BOB BROUILLETTE OWNER ADDRESS:6221 WEST TREE ANCHORAGE, AK 99516 DATE ISSUED: 5/06/98 EXPIRATION DATE: 5/06/99 PARCEL ID:01532234 LEGAL DESCRIPTION: VALLI ~UE ESTATES $2 BLOCK 4 LOT 31 LOT SIZE: 20871 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASK~ WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18DJ~C80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTENUNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED ~5_ND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. RECEIVED BY: ~-~ ~ ~ Rick Mystrom, Mayor Department of Health and Human Services 825 "L" Street P,O. Box 196650 Anchorage, Alaska 99519-6650 May 6, 1998 Steven R. Pannone P.O. Box 142025 Anchorage, AK 99514 Subject: Waiver Request for Valli Vue Estates #2 Lot 31, Block 4 Waiver Request #WR980017, PID #015 322 34 Permit #SW980096 Dear Mr. Pannone: Your request for a waiver of the required 10 foot horizontal separation from the on-site wastewater disposal system to a property line has been approved. The approved separation distance is 5.0 feet. This waiver approval applies to the existing on-site wastewater disposal system to property line separation only. Any future upgrade to the on-site wastewater disposal system will require ali separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, Donna C. Mears Civil Engineer On-Site Water Quality Program MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-site Services Section Waiver Review Worksheet WR# WR980017 PID# 015-322-34 HA# Date Received: April 30~ 1998 Legal Description: Lot 31 Block 4 Valli Vue Estates Engineer: Steven R. Pannone~ P.E. Permit PO Box 142025, Anchorage, Alaska 99514 Applicant: Bob Brouillette Waiver Requested: north property line. Lot line waiver of 5 feet from the absorotion field tn Criteria: 1. Geology: Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: Special Conditions: 3. Other: Waiver is Granted: Waiver is NOT Granted: List Conditions or Reasons for above: Date: Rec ~: #03817 Amount: By: $ 115.00 Name of Reviewer Date Paid: April 30~ 1998 Steven R. Pannone, P.E. Consulting Engineer (907) 272-8218 P.O. Box 142025 Pmchorage, Alaska, 99514 (907)272-8218 Fax April 26, 1998 Municipality of Anchorage Dept. of Health & Human Services On-Site Services Section P. O. Box 196650 Anchorage, Alaska 99519 Subject: Lot 31 Block 4 Valli Vue Subdivision Emergency Septic Upgrade Request Gentlemen: My firm was contacted to investigate a failed septic system on the referenced lot. Upon our arrival, effluent was spilling onto the ground surface from the septic trench. A-plus home service was contacted to pump the system dry. The tank clean-outs were not able to be located. A single test hole was excavated on April 22, 1998. The soil report and percolation test results am attached. Ground water was monitored for seven days. No ground water was encountered or monitored. No bedrock was encountered in the test hole. The lot is approximately 0.75 acres in size. Lot 31 slopes to the northeast at a rate of approximately 2 to 10 percent The proposed installation will be located on the northeastern portion of the lot. The proposed location will be greater than 200 feet away from the community well serving this property and 25 feet from the water service lines. The surrounding systems are located greater than 50 feet from the proposed installation. The proposed installation shall not impact the future development of the surrounding or existing lots. See attached design. The new system will maintain over six feet vertical separation to the bedrock, over four feet vertically to the ground water and over 100 feet to surface water. To install this system to meet the above requirements, I request a lot tine waiver of five feet to the north lot line. If you have any questions about the proposed installation, please contact me at 272-8218 Sincerely, Steven R. Pannone, P:E. Attachments: RER~IT NO, DESIGN V/ASTE;~/ATER ABSORPTION SYSTEM LOT 31, ])LOCK 4 VALLlkYUE EXIST. SEPTIC ON LOT 32 IS LOCATED IN THE N~ CORNER OF THE LGT. PROPOSED REPLACEMENT DRAIN FIELD, 84 LF x 3 / LINE TPI// P,I.D, ND. Ci\Vork\31-4VVUE,DWG PROPOSE]3 1,250 SEPTIC TANK VALI VUE IS SEARVEI) I~Y A NO ~/ELLS WITHIN ~OO' Of pRopOSE13 INSTALLATION, EXISTING SEPTIC SYSTEM ARE GREATER THAN 50 FEET AVAY FROM THE PROPOSEI] SYSTEM, PREPARED FUR~ Mr, Robert BrouJilette 6221 West Tree Drive Anchor:ge, AK 99516 (907) 346-2288 EXIST. SEPTIC ON LOT 30 IS LOCATED IN THE S~ CORNER OF THE LOT. DESIGNI Pert Rate, 1G MIn/lnch Soil R~lng, 0,6 gpd/s? 4 II.R, 1000 SF RequireW Deep Trench 6~ E?Fectlve, 2-3~ ~Vide, 9' To~l Depth, 84' Long 1008 SF To~l PANNONE ENG, SVC P, ~, BOX 142025 ANCHORAGE, ALASKA 272-8218 99514 DATE, 4-27-98 I DESIGN ~CALE, NO, PERMIT ND. gESIGN DETAILS WASTEWATER ABSORPTION SYSTEM LOT 31, t)L~3CK 4 VALLI VUE lnDN¥393 z Ld C~\Work\31-4VVUE,))WG PREPARED FDR: Mr, Robert 3roulllette 6221Wes~ Tree Drive Anchorage, AK 99516 (907) 346-8888 PANNDNE ENG, SVC, P, D, BOX 142085 ANCHORAGE, ALASKA 99514 874-0308~ 578-8818 FAX ~TE~ 4-87-98 NDT ~ S-~-LE/ DESIGN Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST DATE PE~FOR~ LEGAL DESCRIPTION: {"~ll~"~ q VAILI V'OE., Township, Range, Section: OEPTH 2 3 4 § 7 8 9 13 14 ~7 18 ~9 20 COMMENTS 5 r L'-n3 SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth Io Water Alter Monitoring? Date: SITE PLAN I / /' Gross Net Depth-~ Net Reading Date Time Time Water Drop ~l-~'-~lf6 ?:3 ~ ~-- ~" ~: ~ ~ ~ ~ '1~ ,1~ PERCOLATION RATE __ TEST RUN BETWEEN (minutes/inch) PERC HOLE DIAMETER ~'~) FTAND ~ FT PERFORMED BY: ~-~'~,4.~,~ ~ ~ ~ ~ ~..CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~(['~ ~--'~ ~:~ 72-008 (Rev. 4/85) GRE/ ' ANCHORAGE AREA BOR""- IGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: INSIDE LENGTH INSIDE WIDTH MATERIAL LIQUID DEPTH NUMBER OF COMPARTMENTS / LIQUID CAPAdITY/~GALLONS. TILE DRAIN FIELD: DISTANCE FROM WELL NUMBER OF LINES ABSORPTION AREA DEPTH: TOP OF TILE TO~INISH GRADE ~/~'/ ~-w~/ 'FOUNDATION ~7 / ! TOTAL LENGTH NEAREST LOT LINE /~'~'~ OF LINES / DISTANCE BETWFEN LINES TRENCH WIDTH ''~ / IN. TOTAl_ EFFECTIVE GTH OF EACH LINE DEPTH OF FILTER MATERIAL BENEATH TILE (~ IN. ABOVE TILE ~ // IN. WELL: ~ ~ TYPE CONSTRUCTION __ DEPTH BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION LOT LINE __ SEWER LINE TANK SYSTEM DISTANCE FROM: CESSPOOL OTHER SOURCES APPROVED DISTANCES: INSTALLED DISAPPROVED REMARKS ~ 7~.¢_.~.,2~3._~,'~LT...,,"~DIAG RAM OF SYSTEM SEWER LINE DEPTH: LOT SLOPE: REMARKS; " G.A.A.B. Form EQ-032 .- % GRE./'~-'~R ANCHORAGE AREA BOF'~"~JGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 'C' STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYS/TEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT'T~/~· PROSECUTION. FOUNDATION TO SEPTIC TANK '~'~ / FOUNDATION TO SEEPAGE PIT SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK TO NEAREST LOT LIN . WATER MAIN TO SEPTIC TANK SEEPAGE PIT DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT OO~'~FORM TO ' O RO::~U LATION' "EGARE I ~ G:~O¢ '~ CERTIFY THAT I AM~tLIAR WITH THE REQU~ GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE Test Hole No. 1 Depth in Feet From To 0.0' 0.5' 0.5' 5.0' 5.0' 7.5' 7.5' 14.0' 14.0' 20.0' Bottom of Test Hole: Frost Line: Free Water Level: TABLE A W.O. ~17460 Soil Description F-4, brown,.sandy peat, Pt, over- burden, medium density F-4, tan, gravelly sandy silt,'ML, damp, hard, maximum subrounded particle size of 3" F-2, tan, very silty sand, SM, damp, medium density, with about 3" to 6" layer of NFS sand at 7.0' F-4, tan, sandy gravell~ Silt, ML, occasional cobbles, damp, hard,. subrounded particles to 9" F-l, tan, s~lty sandy gravel, GM, damp, high density rounded particles to 9" 20.0' None Observed None Observed Remarks: 1. Test hole pit. placed 15.0' to the side of septic tank WATER LEVEL W O ~/~Op.% DATE. ~ "/rI' ?..C' STATION ._ " " AD DRILL TIME SIT., FN. _ GR. COVER " " ~4hr. CASING. SIZE., TEC~, 4/'/'/_ ~IEZOMETER YES NO $.T D. ~C- N. ' GRAVELS NFS, F1 WELL GRADED GRAVELS F3 WELL GRADED NFS, GRAVELS SANDS NFS, F2 WELL (;RADHD SANDS F2, F~- WELL GRADED SP SANDS NFS, F2 POORLY GRADED SiLT 4040 "B" STREET, ANCHORAGE, ALASKA 99503 PHONE: 907-279-2581 August 16, 1975 WO #174.60 Mr. John L. Sullivan John L. Sullivan & Sons Construction Box 10177, Klatt Station Anchorage, AK 99502 Subject: Subsurface Investigation for feasibility of On-Site Sewer, Lot 31, Block 4 Valli-Vue Estates Dear Mr. Sullivan: :As per:your=i~struc%i~nsi=w~pl~ced---a~:test hole-onthe above ........ referenced lot to 'a depth of 20', as located on the enclosed location sketch -- Figure 1. The test hole was placed with a truck mounted Mobile Drill B-50N drill rig owned and operated by Denali Drilling, Inc. The test hole was logged and the drilling supervised by Mr. O.M. Hatch, senior technician/ staff geologist with our firm. The soils encountered were fairly marginal with the better soils beginning about 14' The test hole was drilled to 20' to determine that enough of the layer was above any water table, that might exist,.to be fully utilized. No water table was observed within the full 20 foot depth of the test hole. The hole was initially filled with water mt:~:J5 p.m. on August 14, 1975. It was allowed to percolate and refilled again at 9:00 a.m. on August 15, 1975 and monitored closely until 1:00 p.m. that same afternoon. The average percola- tion rate during this time was 7.5 minutes per inch. Utilizing, Figure 3-- "Absorption Area Requirements for Private Residence" on Page 9 of the "Manual of Septic Tank PTactice", published by the U.S. Department of Health, Education, & Welfare a percolation rate of 7.5 minutes per inch requires 145 square feet per bedroom of absorption area. We hope that this data is sufficient for your needs. If we can be of further service or offer guidance or clarification on any matter pertaining to this report. Please do not hesitate to contact us. Very sincerely yours, ) Melvin R. Nichols, C.E. Laboratory Supervisor MRN:rb Enclosures 32 20 3O 26 24 23 4/ GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "C" Street, Anchorage, Alaska 99503 274-4561 Date Received January 24, 1977 Time Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR 1. Approval Mailing Address: 2. Property Owner: Wailing Address: 3. Legal Description: 4. Location: Last of Inspection Administration % Fern requested by: State of Alaska, Veteran's 907 West Northsrn Lights John L. Sullivan Phone: 274-7555 Phone: 344-9062 10-177 Klatt Station Lot 31 Block 4 Valli Vue house on right side (West Tree Drive) 5. Type of facility to be inspected Single Family No. of bedrooms 6. Well Data: A. Type Community B. Depth C. Construction D. Bacterial Analysis 7. Sewage Disposal System: On-site system A. Installed 1975 ~(x~, B. Installer C. Septic Tank: 1. Size 2. Manufacturer D. Seepage Pit: 1. Absorption Area 2. Material E. Disposal Field: Total length of lines 8. Distances: A. Well to: Septic tank , Absorption area Nearest ]ot line , Other contamination Foundation to septic tank , Absorption area C. Absorption area to nearest lot line 4 , Sewer Lines , EQ-034 (1/74) Page I of two pages Page 2 of two pages - Re~'~st for Approval of Individual ~-~er & Water Facilities ~Fe~a]' Description Lot 31 Block 4 Valli Vue Comments Approved ~C i ~/~/~~ sapprOved Date //~/~ Approval Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. ~ SIGNED Date EQ-034 (1/74) /VIUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION ENYIRONMENTAL PROTECTION 2510 East Tudor Road, Anchorage, Alaska 99504 276-2221 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WAT~ER FACILITIES CM,O VA / X' 1. Type of Inspection: 2. Property Owner: ~(.~ 1\ i~ Mailing Address: 4. Name of Lending Institution: Mailing Address:C~0 5. Name of Realtor or Agent: JAN ~ 4 1977 RECEIVED CONV. Day Phone: ~--?(~ ~ '~£ Mailing Address: 6. Legal Description: ' LoT Location: O'~T 7. Type of Facility to be Inspected: 8. Water Supply Type of Supply: Public Utility If Individual, number of dwellings presently served Day Phone: Phone: rlndividual If Individual, depth of well 9, Sewage Disposal System Type of System: Public Utility Individual (on-site] If Individual, date of installation ~ ~E-~'~- ~[~,~ 72-003(3/76) January 27, 1977 R & M NO. 751502 Mr. John Sullivan Box 10-177 Klatt Station Anchorage, Alaska 99502 Re: Percolation Test on Existing Disposal System; Lot 31, Blk 4, Valli- Vue Estates, Anchorage Alaska Dear Mr. Sullivan: On January 26, 1977, at the request of Mr. ~rB~, our office conduc- ted a percolation test on the septic system~ on the above describ- ed lot. The following table represents the level of the liquid in the gravel filter below the leachfield. The depth of liquid in the filter was initially 12.2 feet below the top of the stand pipe. For the test, the liquid level was measured from the top of the stand pipe. Summary of Measurements Level of Liquid Meter Reading Time in Gravel Filter in Gallons 0:00 12.22 2,305.2 (initial) 0:44 11.53 2,536.0 1:02 11.23 2,631.0 3:45 11.59 2,631.0 (final) The meter used during the test was a Rockwell 5/8" standard water meter. The meter had previously been calibrated by R & M Consultants, Inc. Since the house on the lot concerned was occupied, it can be assumed that the leachfield in question was at its normal degree of saturation. If it is assumed that the existing four bedroom residence will house eight people, the average daily load on the disposal system can be expected to be 600 gallons per day, or 0.42 gpm. Mr. John Sulliv~l ~anu~y 27~ ~937~ Page 2 Since the existing disposal system accepted 117 gallons in 163 minutes or 0.72 gpm, I would conclude that the leachfield is presently perform- ing in an acceptable manner for a private residence. A Copy of the calculations that were used to determine the system's capacity are enclosed. If you should have any questions concerning this test or this letter, please do not hesitate to call. Very truly yours, R & M CONSULTANTS, INC. Ed Yarmak, Jr. Geotechnical Engineer EY:mh Enclosure CALC. aY'. ~'~ J [DATE: / -- Z ~¢~ --77 m DATE: