HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 6 LT 9Onsite File Valli Vue Estates #2 Block 6 Lot 9 #015-311-54 1974 seepage pit is undersized and void was filled as part of 2021 permit. Seepage pit cannot be tested for COSA approval. Ai._ Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 of 3 ON-SITE WASTEWATER INSPECTION REPORT �1100,1P Permit Number: OSP211201 PID Number: 015-311-54 Dwelling: X Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New X Upgrade Name CAROL WEDDLE ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑ Bedand Site Address 6711 ROUND TREE DRIVE *ANCHORAGE, AK El Other Phone Number c f Bedrooms Soil Rating Total depth fro original grade 907-229-8675 5 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. ravel depth beneath pipe Ft. Subdivision Block Lot VALLI VUE ESTATES #2; BLOCK 6, LOT 9 Fill added above original gra Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES 0 Septic Absorption Lift Station Holding I Sewer tal Toption area a r Number of trenches Dist. between trenches From Tank Field Tank Line Ftz Ft. Well — _ _ _ — TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER TANK Capacity 1500 Gal. Surface Water 100'+ - 100'+ - Material Number of compartments Lot Line 10'+ - 10'+ - NA HDPE 2 Foundation1 ��� - 10'+ LIFT STATION Manufacturer Capacity Remarks PER CONTRACTOR OLD TANK WAS REMOVED AND DISPOSED G R E E R TA N K 1000 Gal. Alarm location f ,, , t GARAGE �— Electrical installed bycfe fZ EXISTING E, -= Inst ffer PIPE MATERIAL House `to tank D3034Tank to D1785 drainfield A+ HOME SERVICES _ Drainfield D3034 CO/MTD3034 Inspector GEG AND MOA BENCH MARK (Assumed elevation) 100.00 ft Inspdecct sn 1st 12/17/2021 2"d - Location and description 3rd - 4th _ TOP OF MANHOLE #1 (MH1) ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date %s4� nr g T �oo� 0 ........... .............. D Jl f y y A. Garness. Septic System Approved Date DO —7)5 3 p� �4 r� ✓?2,.. I Note: this approval does not include well permit requirements. "100 aneccas4�04Oe tr%"V uarVu toj A January 1811, 2022 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Valli Vue Estates #2; Block 6, Lot 9 — Sump on Southeast Trench To whom it may concern: A design was submitted and approved for the subject property on 6/25/2021. On the permit, it required that the contractor install a cleanout and monitoring tube on both "legs" of the 1985 drainfield. On 12/17/21 the new tanks were installed by A+ home services. The sump on the northwest trench was located and found to be functional. Per the contractor a cleanout and monitoring tube could not be installed on the southeast trench without incurring a significant cost to the homeowner (due to limited access to the drainfield site). Based upon this fact, we are requesting that your department waive locating the sump on the southeast leg of the 1985 drainfield as a condition for issuance of a COSA. Justifications for granting this variance are as follows: • An adequacy test was performed through the sump on the northwest trench. The sump extends approximately 7.3 feet below the invert of the distribution line. Per GEG inspection the northwest trench passed an adequacy test for 5 bedrooms. • During the adequacy test on 11/19/21 GEG again attempted to locate the sump for the south east trench but was unsuccessful. • The sump cannot be installed without unreasonable cost to the homeowner. • Per the 1985 record drawings, the sump should be outside of the utility easement (18' off the north lot line). • There are no private wells on the adjacent properties. If you have any questions, please contact us at 337-6179. Thank you for your assistance. Y, Jeffre Nt6mes_s/P.E., M.S. Presi ent 3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Website: www.garnessengineering.com PERMIT NUMBER: PARCEL ID NUMBER: OSP211201 RECORD DRAWING 015-311-54 A I B MH1 15.0 59.3 ST1 16.5 63.8 DBL1 17.3 64.9 DBL2 17.6 65.8 FD 17.6 66.5 ST2 18.9 69.6 MH2 20.9 73.8 NOTE: PIPE LOCATIONS ARE SHOWN PER GEG SHOTS TAKEN WITH LEICA DISTO S910 LASER DISTANCE METER. SWING -TIES TO HOUSE CORNERS WERE GENERATED IN AUTOCAD. • 4 Q.A 14. v. • .4 A a 1 : •:' .� 4 V C • • d _ v•' 4 a. ^ ST2 •4 / MH d" ° ASSUMED LOCATION OF SEEPAGE PIT; / / SUMP FILLED WITH DRAINROCK AND SUMP l INSTALLED PER A+ HOME SERVICES \ / / Ro N �A SCALE: O APPROXIMATE 1" - 20, R/1 ' KEYBOX LOCATION F IN� EXISTING 5 BEDROOM HOUSE 1&2 CONNECTED TO EXISTING PRESSURE LINE / `NEW TWO COMPARTMENT 1500 LL- GALLON HDPE GREER TANK NEW'T""ALLON HDPE GREER TANK WITH ANCHORAGE Ti LIFT STATION COMPONENTS TO BE USED AS STEP TANK DASHED WATER LINE LOCATION IS APPROXIMATE; SOLID LINE WAS PROFESSIONALLY LOCATED PRIOR TO CONSTRUCTION .•'-�E �P..•••.............♦♦ AV GARNESS ENGINEERING GROUP Ltd • ♦ --_ ENGINEERING -SALES CONSULTING 3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, ALASKA -PHONE (907) 337-6179' WEBSITE: w .gamessengineenng.mm �«._.•. . •••• ...... 0 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: ♦ rey . G mess 4�I 0 CAROL WEDGE 907-229-8675 2 OF 3 ♦j� C 3 '� ♦ �'••,,AV PROJECT/LEGAL DESCRIPTION: DRAWN BY: ♦♦ �� a Yy Z•�J• 4V VALLI VUE ESTATES #2; BLOCK 6, LOT 9 D.J.G. 1i FQ�=pppp............. ••'• P�, �4W TYPE OF WORK: DATE: LICENSE ,1',,lklk L • RECORD DRAWING OF NEW SEPTIC TANK 1/5/2021 #AECC884 PERMfT NUMBER: OSP211201 TOP OF TANK AT INTLET = 96.94 INVERT OF BUNG AT INLET = 96.26 2" INSULATION PER TOP OF TANK AT INTLET = 96.53 OF BUNG AT INLET = 9� - q/'l- eip, v% Nf:�q -,2-j2-jZz RECORD D RAW I N G PARCEL NUMBER: 015-311 1-54 TOP OF MH = 100.00 FINAL GRADE = 99.75-99.92 MH1 STI INSULATION TOP OFTA K ATO OUTLET CONTRACTOR NEW 1500 GALLON H.D.P.E. SEPTIC TANK ST2 MH2 NEW 1000 GALLON H.D.P.E. STEP TANK INVERT OF BUNG AT OUTLET = 96.09 FINAL GRADE = 99.84-100.00 OF TANK AT OUTLET = 96.53 GARNESS ENGINEERING GROUP, Ltd( ENGINEERING SALES CONSULTING - - - 3701 E. TUDOR ROAD, SUITE 101 ' ANCHORAGE, AK 99507' PHONE (907) 337-6179 -FAX (907) 336&3246 - VVEBSITE V gameasengineenng.wm PREPARED FOR: PHONE NUMBER: PAGE NUMBER: CAROL WEDDLE 907-229-8675 3 OF 3 LEGAL DESCRIPTION: DRAWN BY: VALLI VUE ESTATES #2; BLOCK 6, LOT 9 D.J.G. TYPE OF WORK: DATE: ,._ SEPTIC TANK PROFILE 12/28/2021 TANK HOLES WERE DRY DURING INSPECTION PER CONTRACTOR OF 441 AV AF *' ' *♦♦♦ ;................ 0z ........................:....� ♦. Jeffrey A. Garness�: ♦ % CZ. -79 3 ♦ �% i AV LICENSE 4 ; ES\\S . •' #AECC884 / OF q jq�;4p CO '49 r SHANE A. HOLT...' p LS -6914 0` Q�a o �Arofessiona\ foa o THESURVEYDATA AND MEASUREMENTS HEREONAREPREPAREO FOR THE OWNER OFRECORDAS OF THE DATE OF THIS SURVEY. ANY USE OF THIS DRAWING BY THIRD PARTIES IS PROHIBITED UNLESS WRITTEN PERMISSION IS PROVIDED. THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. EASEMENTS OF RECORD OR OTHER RIGHTS OF WAY, OR ANY ENTITY NOT ON THE RECORD PLAT ARE NOT SHOWN HEREON, UNLESS NOTED. NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. ANY PAVING SHOWN HEREON MAYBE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. AS-BU/LTSURVEY I" =301 NO CORNERS SET THIS DATE K1 HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOTS, BLOCK 6, IVALLI IVUENO. 2SUB ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST OTHER THAN NOTED. DATED AT ANCHORAGE,ALASKA THIS 25TH DAY OF JANUARY , 2022 HOL T LAND SURVEYING 9309 GROVER DRIVE ANCHORAGE,AK 99507 15060, FB213-45220-31 22saez5 MUNICIPALITY OFANCHORAGE On -Site Water & Wastewater Program PoBox 1966ao 470DElmore Road Anchorage, Alaska 99519'as5U Phone: 7804 Fax: (9O7)34o-7oS7 Permit Number: OSP211201 Work Type: 5epUoTenkUpgrade Tax Code Number: 01531154000 Site Legal Address: VALL|VUEESTATES #28LK 6 L Q G:2538 Site Mailing Address: 8711 ROUND TREE DR, Anchorage Owner CSW LIVING TRUST Design Engineer: GARNESS ENGINEERING GROUP LTD This permit ksfor the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 6/25/2O21 6/25/2022 El Disposal Field 10 Septic Tank 0 Holding Tank E3 Privy E3Private Well 0 Water Storage All construction shall boinaccordance with: 1. The attached approved design. 2. All requirements specified inAnchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska VVaabswshor Disposal Regulations (i8AAC72)and Drinking Water Regulations (1O/AC8O) 1 The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.85.Provide notification bycalling (0Q7)343'7Q04(24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall beeither: e. Opened and Closed onthe same day, or b. Covered, sealed, and heated hoprevent freezing Special Provisions: 1) The standpipes; at the ends of the 1985 field shall oerepaired/extended orreplaced prior tofuture CUSA approval. It is recommended that this becompleted under this permit, aanoted nnthe site plan. 2) Filling the void space of the seepage pit will prohibit the seepage pit from being utilized for testing for any future OSA. Should utilization ufthe seepage pit have any adverse effects (ia.surfacing ef0uent).the seepage pit shall befully abandnned/d*oommiauiuned. Received Date: -C �' I ) 2-1 OVIUNI"01"PAUITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wast-ewater Section Fax: 907-343-7997 ON-SITE SEPTIC/VVELL PERMIT APPLICATION Parcel I.D. 015-311-54 Property owner(s) Carol Weddle Mailing address Site address 6711 Round Tree Drive *Anchorage, AK Day phone 907-229-8675 Legal description (Sub'd., Block & Lot) Valli Vue Estates #2; Block 6, Lot 9 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) M (w/wo ADU) Septic Tank Fx_1 Upgrade M (D) ❑ Holding Tank ❑ RenewalDuplex ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: n/a Distance: - I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: � v� � 5 Waiver Fees: Date of Payment: 61 -71 AO 2 1 Date of Payment: Receipt Number: 0 5 `l 9 7C? Receipt Number: Permit No. OSFQ 1 1 '� b 1 Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\FormsUient FormsTermit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211201, Rebecca Carroll, 06/25/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211201, Rebecca Carroll, 06/25/21 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211201, Rebecca Carroll, 06/25/21 ...J Of N. < i uj �qU y via P�`� 'x ^vytr` € A7 12 CD " Ell�'_ F 3 ; y" "r) ...J Of N. < i uj '~- MUNICIPALITY OF ANCHORAGE Df. ~RTMENT OF HEALTH AND HUMAN SEK eLS /' ~ Environmental Health Division ,. 825 %" Streetl Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Address ' / ~ SEPTIC ABSORPTION Permit NO No. of Bedrooms~ , WELL ~.~ Ph°ne(s~7 ~ ¢~ ~¢~ LOT LINE , LEGAL DESCRIPTION Township. Range. Seonon TANKS ~; - - Manulactu,er Capac,ty ,n 9allons , '4 l~' Material S~,[~ N°'°fC°mpaflmens~ ~ , ,~,~1 TYPE OF SYSTEM ~ ~, ~YRENCH ~ BED ~ W. DRAIN ~ OTHER ' ' FT ~' FT Total abso'p'lo, 8rea Distance belween lines , 6 Q~ ~4 WELLS~ ~'~. ~ PRIVATE ~ OTHER ,ldentifV) class~h~at~o~ (A,B,C) Total Depth FT C~sed ~oFT I ~ ~ ~ ~ cc~ify thai Ibis inspeclion was pcdormed according to all Municipal and Slate Bui~elines in e(Ject on Ibis date: 72-013 (3/85) D,:.FAR [ME. I I[ gl`: HEALTH AND r£N¢IRONidlENTAL PRO]"ECTION 8.'.75 L. STREET~ ANE;HORAI~.)E.~ Al-,:; 9~5] 1 ~ o4-47,=:. F'EFIIM I T NO: 85()604 DA'l`'iiF ISSUED: AF'F'I_ I CAN l`' .' AD!)FIIESS ,", L:ONTACT PHONE: RANDY WEDDL. E 67'L ] ROUNDTREE ANCHORAGE, AK 274-0666 995:[6 LEGAL DESCRIP: SUBDIVISION: VAL. LI VUE :1~2 LOT: 9 SECTION: :1.4 'I"OWNSNtF:'." :t2N ~ANGE: :_"';W L..OT SIZE: 53200 (SQ.F'T. OR ACRES) MAX BEI)ROOIqS: 5 BLOCK: 6 DEPTH TO PIPE BOTTOM (F'l-.) GRAVEl DEPTH (FT,) TOTAL DIEPTH iiF]~. ) GRAVEL WIDTI`'I (FT.) GRAVEL LENGTH (FT.) GRAVEL vir]~t- UME (CU. YDS. ) "ANK SIZE (GALS) SO]:L. RAT]:NG (SQ.F:T. /BR) Listed belew are Lhe ::)ptic~ns available t.e you in designing youn septic: system. Choose the option that best ¢its youp site. 4.0 4 ,, 0 4 ,, 0 8.0 0.5 3.5 2.5. ~e 29.0 5.0 71.()'~ 56. ] 122.0 ~.~ 55. v 60.2 90.4 1,500.0 ~"~ 1,500..0 -~- ~.,500.0 .l~ ~ GRA.EL LENG]'H > ~5 FT. REQUt.~ _TIPLE RUNS (NOT EXCEEDING 75 FT. EACH) ':"~ TANK MUST HAVE A'I LEAS'f TWO COMPARTIqENTS I c:er"LJ. Fy Lhat: 1. I am familiar with the requirements for on-site sewers and wells as set Fopth by the Municipal:ity ef Anchorage (MOA) and the State of Alasl<a. I will install the system in accordance with all MOA cedes and regulations, and in compliance with the design cr'iteri~ or this permit. 3. I will adhere to ali MOA and State e¢ Alaska r, equirement, s CDr the set back distances From any existing well, wabtewater disposal system or' public sewer'age sys'Le~i~ on this or any adjacent or ]ear'by lot.. 4. I under'stand that this Detroit is valid For' a maximum oF 5 bedrooms and any enlar'gement will requipe ~n additional ]ermi'L. IF A L. IF'T STA'TIOIq IS INSTALL. ED IN AN AREA COVERED BY M[]~ BUILDING []ODES, THEN (1) AN EL.EC]"RICAI_ PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUIL. TS WILL_ I\IO'i BE AF'F'ROVED WtTHOU'T' AN ELE'CTRICAL INSF'E:CTION REPORT; AND (3) 'FHE ELECTRICAL WORK MUST BE-.': DONE BY A LICENSED ELECTRICIAN. · .:I ]. GNED Al ~ LI[,AIIF,, ~ ,~: ~: LE £ Et",' DATE: RANDY~.FDDLE Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST (ENGI~AL) PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 ~4 5 6 7 -8 9 10 11 12 13 14 15 16 17 18- 19- 20- DATE PERFORMED: ~--~) ~ ~ Township, Range, SOCUOR: ~ [¥ ~--l~ ~ r~.~ ~ SLOPE SITE PLAN Ill WASGROUND WATER ENCOUNTERED? S IF YES, AT WHAT DEPTH? p E Depth to Waler After Moniloriflg? D~le: p.~ p¢~'l~ Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE __ (minutes/inch) PERC HOLE DIAMETER __ TEST RUN BETWEEN -- FTAND FT ,/~"~,,,~ S r" ~,-~l~,._,~,~ i ~7~ERTIFY THAT THIS TEST WAS PERFORMED IN PERFORMED BY: / ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE, DATE: /(~ -' ;Z- ~ ~'- 72-008 (Rev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: DATE PERFORMED: ~:~/ ','~ ~t ~ LEGAL DESCRIPTION: /~cJ'~ q ,E/c~K g V~/h' C/ye ~ ~' Township, Range, Section: ~-~,/q 'TI ~--~JP-~,.J ,,q~--/~ T/Ca- 1 2 3 4 5 6 7 8 9 10 11 13- 14- 16- 17- 18- 19- 20- COMMENTS ~c'o,'! ~o,,~ I.,~- -/~ /6 SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? s L iF YES, AT WHAT O DEPTH? p E Depth Io Waler After Moniloring? Date: Gross Net Depth to Net Reading Date Time Time Water Drop /1~, '7 I~ , 3,~'~ . e ~ 113~ - ,5'0 /~ y9 ,,~-= - ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE1 DATE: 72-008 (Rev. 4/85) PERCOLATION RATE ~0- ~ (minutes/inchl PERC HOLE DIAMETER ~'-' ~* TEST RUN BETWEEN .2. FT AND ~"~' FT ~".~ I[ ~~: CERTIFY THAT THIS TEST WAS PERFORMED IN ' INSPECTION REPORT MUNICIPALITY OF ANCHOR~i~E, BUILDING SAFETY DIVISION 401 w. INTERNATIONAL RD. INSPECTIONS (907) 563-3464 ADMINISTRATION 1907~ 786-5700 FOOTING [] ELEC. TEMP. [] PLBG. UNDGR. [] FOUNDATION - [] ELEC. SERVICE . ' [] PLBG. ROUGH · [] BOND BEAM [] ELEC. ROUGH .~ GAS TEMP.. [] FRAMING [] ELEC. FINAL GAS [] INSULAT,ON - [] OTHER -. [] MECHANICAL [] SHEETROCK [] . - MECH. FINAL [] STRUCT. FINAl" [] FIRE FINAL - [] 'PLBG. FINAL [] OTHER -- [] ZONING . [] OTHER . [] [] NO NONCOMPLIANCE OBSERVED [] CORRECTIONS ESSENTIAL AS EXPLAINED BELOW [] WILE REEXAMINE AT NEXT INSPECTION ?~ DO NOT CONCEAL UNTIL REINSPECTED · ' INSPECTOR //- ~ WHE / DATE N CORRECTIONS ARE MADE, ~5~EA~~ CALL FOR INSPECTION wirer:. C;ORRECT~~ CALL FOR INSPECTION DO NOT REMOVE THIS NOTICE GRF'?:R ANCHORAGE AREA Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME "T~/~)BZ.,~ ~Z~M}-~/3~]~3 MAILING ADDRESS PHONE LOCATION ~)CL/J~) -"~/~E~ ~)~IVC. LEGAL DESCRIPTION ~.~)~- ~ 8~ ~ U~./~f' SEPTIC TANK: DISTANCE NUMBER OF FROM WELL~;F/y//~?' MANUFACTURER~J~L~¥AE~-~ MATERIAL'S/-~' /~//~/ COMPARTMENTS ~ INSIDE LENGTH ~- INSIDE WIDTH ~ LIQUID DEPTH ~ LIQUID CAPACITY. ?ODD GALLONS. SEEPAGE PIT: NUMBER Of PITS / LINING MATERIAL ~l BUILDING FOUNDATION / DIAMETER ~ OR WIDTH /(~',/ LENGTH~'~', DEPTH /~ / CRIB SIZE: DIAMETER ~///DEPTH c~ / DISTANCE FROM: WELL~- r TOTAL EFFECTIVE NEAREST LOT LINE c~d~ ABSORPTION AREA (WALL AREA) ~' .SQ. FT. ADDITIONAL ABSORPTION WELL: TYPE ~F~.~_ ~/~. ~.~ BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION DEPTH DISTANCE FROM: NEAREST NEAREST SEPTIC SEEPAGE LOT LINE SEWER LINE TANK SYSTEM OTHER SOURCES DISAPPROVED REMARKS DISTANCES: INSTALLED BY: '~//~ PIPE MATERIAL: LOT SLOPE: REMARKS: Form NO. ED-031 DIAGRAM OF SYSTEM GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C' STREET ANCHORAGE, ALASKA 99503 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT INSTALLATION LOCATION ~"~/~'/~/T , MAILIN~ ADDRESS PHONE INSTALLATION OF: SEPTIC TANK SEEPAGE PIT TYPe AND size Of FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS COMP LETION DATE ANTICIPATED TO BE INSTALLED NOTE: THI~ PEI~MIT I$ NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO FOUNDATION TO SEEPAGE PIT ,"~'¢'~ ~--~ , DRAIN FIELD SEPTIC TANK , SEEPAGE PIT TO NEAREST LOT LINE. WELL TO sePtiC TANK J~////~/~ / WATEr MAIN TO SEPTICT NK SEPTIC TANK, /~ I SEEPAGE Pit /~ / , SeEPAGE PIT ,//~O.'~'///'~), --, , ALSO CONSIDER AREA WELLS, .SEEPAGE~'T /~/ CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SO]L. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS ]N ACCORDANCE WITH SAID CODE. ~k~.-- Performed For Legal Description: Lot ~ __Block ~ _ This Form Reports Soils Log~<~ - Soil Test Must Be Logged To 4' Depth Feet Soil Characteristics GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" Street ANCHORAGE, ALASKA 99503 Case # ~k3h--~i~l~Rt S E~ Dated Performed Subdivision ~., ~'¢~ ~}~//J ~/m~ ~ercoi a~ion Test ll-- 12-- 13-- 14-- Below Proposed Seepage System Was Ground Water Encountered? If Yes, At What Depth? Reading Date Gross Time Net Time Depth to H20 Percolation Rate Mi nu-ce Proposeo Installation: Seepage Depth of Inlet Depth to Bottom COMMENTS: Drain Field of Pit Or Trench Net Dro Certi fied BY: Date: MUNICIPALITY OF ANCHORAGE HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date iNFORMATION Legal Description (inctude lot, block, subdivision, section, township, range) Location (address or directions) .._.. '"', . 'zn /~pplicant Name:~ ~d~, /-~*dJ~//~ Telephone:Home (c) Applicant is (cheek'bne): Lending Institution Business ~ ~"-'l ~ (d) Lending Institution Telephone Address (e) Real Estate Company and Agent Address Telephone (f) Mail the HAA to the foJlowing address: TYPE OF RESIDENCE Single-Family~ Multi-Family [] Number of Bedrooms ~ Other 3. WATER SUPPLY Individual Wail [] Community J~/ Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. $~WAGE DISPOSAL Onsite~/ Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (11/84) B. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this ~ Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adeq~ for the number of bedrooms and type of structure indicated herein. I further verity that based on the information obtai from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm /r~'~' '~ ~{'~C. Telephone ~-'~{'~ G'cg~PP Date {<~-[ - ~ ~ Approved for ~ bedrooms by te Approved ~ Disapproved Conditional Terms of Conditional Approval CAUTION The Muncipa~lity of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Description: MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION Well Log Present (Y/N) /(/4 Date Completed ~"~- ' Yield Total Depth ,~,/~ Cased to AZ/~ Depth of Grouting Static Water Level ~ Pump Set At Casing Height Above Ground .-~..4 Sanitary Seal on Casing (Y/N) 'Electrical Wiring in Conduit (Y/N) ,~/~ Depression Around Wellhead (Y/N) Separation Distances from Well: TO Septic/Holding tank on Lot ~ ~ .=-~6'~'~ ; On Adjoining Lots To Nearest Edge of Absorption Fieid on Lot~., 7''L ..~c~/ ; On Adjoining Lots To Nearest Public Sewer Line ,/~/~' To Nearest Public Sewer Cleanout/Manhole ,,~/~'~- To Nearest Sewer Service Line on Lot Water Sample Collected by -'~,~ ~ Date Water Sample Test Results Comments SEPTIC/HOLDiNG TANK DATA ,~.'~/ Date Installed~- ~,~' Size Standpipes ~N) Depression over Tank (Y/~4)~ ~'E;~:~ :~No. of Compartments Air-tight Cap~N) Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) /~-//~ Separation Distances from Septic/Holding Tank~ To Water-Supply Well (~-"~- / TO Property Line '-~'~-- To Water Main/Service Line /- Course ~'~ /0~ Comments Foundation Cleanou~) Date Last Pumped ;for Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field f To Stream, Pond, Lake, or Major Drainage Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed I Width of Field Square Feet of Absorption Area Depression over Field (Y/~) Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well ~ ~- To Building Foundation ,~- To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Type of System Design Length of Field / / Depth of Field /f2 ~- ('~- Gravel Bed Thickness ~' Standpipes Presentt~N) Date of Last Adequacy Test To Property Line To Existing or Abandoned System on ; On Adjoining Lots To Cutbank (if p~sent) /cd Comments D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for ,,~.~ Electrical Code~) Comments / Dimensions .,;~/;/cz /~' ¢?/~/~¢..¢~,..~¢, ~' ~ /~ "Pump Off" Level at ,%~ Vent (Y/~ Pumping Cycles during Adequacy Test. Meets MOA Check Permitted Bedroom Rating Against HAA Request ** I certify that I haw checked, verified, or conformed to all MOA an d..~.HAA guidelines in effect on the date of this inspection. Signed ~ ~ Date Company A~'~5 ,.~-~- ' MOA No. Receipt No. ?.¢~U,..~ '~ Date of Payment Amount: $ Page 2 of 2 72-026 (~ 1/84) DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, ALASKA 99501 RILL SHEFFIELD, GOVERNOR Telephone: (907) Address: 274-2533 To Whom it May Concern: j~ {/~¢ According to records on file in this office the ~~~~uL~/~Jt~ Water System is in compliance with the St~e Drinking Water Regulations Sincerely, 4. Sewage Disposal Onsite ~ l~blic ~ Com~nunity ~ Holding TapX ~ is the wastewater disposal system adequate fcr the rtlmber of bedroc~ns (Y/N) [Pa~ 1 of 2] 2-15-84 ROTOR ROOTER SERVICE CALL HRS. STEAM THAWING HRS. TRIP CHARGE HRS. OVERTIME CHARGE HRS. ADDITIONAL LABOR CHARGE HRS. PUMPINGSERVICE~ :.q~ GAL) HRS PLUMBING REPAIR CHARGE HRS MATERIALS PLEASE PAY FROM THIS INVOICE TOTAL I/,/ -'~ ) TOTAL FOOTAGE CLEANED OR THAWED BLADES USED PROBABLE CAUSE OF STOPPAGE ~ LINE CLEANED %! ~-. " '" :" ' ' [] JOB NOT GUARANTEED FOR FOLLOWING REASON WORK ACCEPTED BY MUNICIPALITY OF ANCHOP~RGE Di-v'ISION OF ENVIRONMENTAL HEALTH DEPARTME~If OF HF~kLTH AND ENVIRONMENTAL PROTECTION APPLICATI(IN FOR HEALTH AUTHORITY APPROVAL CERTIFICATE 1. General Info~nation Application Date (a) legal Description (include lot, blcck, subdivision, section, townsh'ip, range) Location (add,ess or directions) (b) Applicants Name ~¢~,~-~. ~. ~f~-%%~% Telephone ~_~ --.~ Applicants Address ~. ~ ~Q~ ~ (c) Applicant is (check one) Lending Institution ~; Owner/builder Buyer ~; Other I t (explain); (d) ~nding Institution ~¢a..~\~ .k~-~'~%~ ~1~_%%<~ Telephop. e Address ~-~ 'xN~_-~ ~-..) _ ( s ) P~eal Estate Co. & Agent _____~-k%~-%\~x-~.~..%-~. \-~c~ _C'~ Telephone 2. Type of ~idence Single-Family ~ Ntunbe~ of Bedro~ns " Suopl_y. >o Water Individqal Well Multi-Family Other (c~scribe) Cca~unity ~ Pdblic ~-~.. , Note: If ~nity ~11 system, must have w~itten confi~nation f~cm the State Depa~tn~.nt of EnviroD~rsntal Conc~rv~tion attesting to the. legality and status. Is the well adequate fo-~ the number of be(l~ocms specified in this ~%A ~N) Sewage Disposal Onsite ~ t~blic E~ Community ~ Holding Tank. ~ Is the wastewater disposal system adequate for the rnmbe= of b~drcx~ns (Y/?4) [Page 1 of 2] 2-15-84 5. Engineering Firm Providing Inspections, Testsr D~ta and Information I certify that I have checkedr verified, c~ conformed to all ~)A H~A Guidelir~s effect on the date of this inspection. Nam~ of Fi~~_C~ Telephone Signed by · OF ua~e >/,'~ I ~_Ji_ , ) ~¥'~° 6 DH~*~Droval ~(-~,n~,> ~e ~r~,~-d,~ Approval ~~ap~o~d ~ Co~dit io~a~ ~e Municipality of ~chc~a~ ~p~nt of ~alth and Er. vi~o~ntal L~otection d~ not ~a~anteo t~ ~ntinued satisfactory ~fo~a~ of tl~ wate~ supply ~d/~ tl waste~te~ dis~sal system. ~is approval indi~tes that, as sh~;n ~, ~d on t~ ~ta and info~tion f~nished ~' ~ e~ineer registere( the State of ~aska, ~e v~te~ supply ~d ~stewate~ dis~sal system is safe and tional for the ~ of ~ ~d t~ of s~uct~Ee indicated. (DHEP SEAL) 7. Mail the HAA to the Yollodi.ng add~'ess: KB2/d5/s []Page 2 of 2] 2-15-84 DEFr. OF HEALTH & HE~,TH AUTHO~TY A~P~VAL '(HAA) ENVIRONMENTAL PROTECTION C~LI~ - FEBRU~Y 1984 I JAR REc'EIVED Well ;Classificatibn 2~%x~ If A,'B, ~ C, D.E.C. ~P~o~) Well ~ ~esent (Y~) ~/~ Date ~le~d ~/~ · Yi~'ld Total ~p~ ~ , ~d ~ ~./~ ~pth of G~outing Static Water Level ~/~ Pump Set At Casing Height Above Ground ~//~ Elect]zical Wi~ing in Conduit (Y/N) ~.//~. Separation Distanoes f~c~ Well: To Septic/Holding Tank cn Lo~ ~.//~. To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line ~/~ C leanout/Manhole ~,.~ ./J:~ Water Sa~le Collected By ~/~ Water Sample Test Results C~taL~nts Sanitary Seal on Casing (Y/N)~/~. Depression A~ound Wellhead (Y~_~_~ ; On Adjoining Lots ~ ; On Adjoining Lots ~.\ To Nearest Public Sewer To Nearest Sewer Service Line on Lot ~/~ ; Date B. SEPTIC/HOLDING TANK DATA Date Installed ~/-~.d~ Size \C)~ ~x__ . NO. of Cc~partments ~ Standpi~s ~) Ai~-ti~t Ca~) F~tion Clean~t ~) ~p~ession ove~ Ta~ (Y~ ~te ~% P~d .. ~/~ /~ P~ing~intenan~ ~n~a~ ~ File (Y~) ; for ~ Holding Ta~ High-Wate~ Ala~ (Y~) ~. ~ra~y Holdi~ Tank ~t (X~) ~/~ ~p~ation Distan~s ~ ~ptic~olding Tank: / TO Water-Supply ~11 ~ ~ ~ To ~ilding F~ndatiog . -~ To ~o~rty Li~ ~ ~ To Dis~sal Field ~ ~ ~ To ~ter Mai~Se~vi~ Li~ ~~ To S~e~, ~nd, ~e, ~ ~jor ~aina~ [Page 1 of 2] 2-15-84 [~ ~o ~ eS~d] · 3se~ ~3~nb~p¥ bujgmp ssi3AD bulctund (N/~) 1USA suoj suem!(] (N/X) sepoD I?OlaloaI~ suoII~D u! ezlS P~ii23sui s3~(] 'D ALASKA elldlROrlme[1TAL COI1TROL SEI utC $, IrlC. ~nclin¢¢rin§ $ ~nuironmental Studie~ March 6, 1984 Lyman King SRA Box 36F Anchorage, Alaska 99516 Dear Mr. King: On March 6, 1984 I investigated the property at _ ~O~D~v . L9, B6 in order to try and find out where the wa~'er servzce line to the house was. Using a TW-5 M-Scope, we managed to trace the water service line from the key box at the edge of Roundtree Drive to where it enters the house. The line runs North for 40', then swings to the East to go around a grove of trees which line the East side of the septic tank. It then swings NW to enter the house 6' North of where the septic line leaves the house (see Figure). The cleanout to the disposal field was also located. It is at ground level, of 4" cast-iron, and is capped. The top of the crib was -3.6' below ground level and the water level was at -4.9'. If the dimensions given in the MOA inspection of 8/74 (18 x 28), are correct, then the water service line, which is 23' from the field cleanout, is not in violation of any regulations. If you have any questions please contact me. Sincerely, ~nU~en:~a i Scientist 1200 LUest 33rd ~ucnu¢. $uii¢ J~ · ~nchora§e. Aleska 99503 o{907] 561-5040 ALASKA ENVIRONM~.. ,rAL CONTROL SERVICES, INC. 1200 West 33rd Avenue Suite 13 ANCHORAGE, ALASKA 99503 Phone 276-1361 SHEET NO. OF CHECKEO BY DATE SCALF ALASKA el dlROFImerlTAL COFITROL Se[ uICeS, IFIC. ~nqin¢¢rinq ~ ~nuironment~l Stucli¢~ March 5, 1984 Department of Health and Environmental Protection 825 L Street Anchorage, Alaska 99501 Attn: Keith Bandt Legal: Valli Vue #2, Lot 9, Block 6 Dear Keith: On March 3, 1984 I performed a Health Authority on Valli Vue Subdivision #2, Lot 9, Block 6. We were not able to locate the cleanout into the disposal field. This house is on a Class A community well. There are no as-builts available for the location of the water lines leading from the water main to the house. Two key boxes were located between this house, L9 B6, and the lot which is immediately to the East of this, L10 B6. The water line enters the house on the East side, some 6' North of where the sewer lines exit the house. There are some large (15"+) diameter tress in a direct line between the key box and the site of the water line entry into the house (see figure). The water lines would have to go West of the trees, which would put them within 4-6' of the septic tank cleanout, or go East of the trees, putting them over 15' away from the septic tank cleanout. Either way, the water line appears to clear the disposal field by a safe margin. Without excavation, there is no way to determine exactly where the house water lines run. It is unlikely that either the septic system or the water lines could have been installed as close as 4-6' to each other without the contractor or inspector being aware of the existence of the other. We recommend that a conditional Health Authority be issued contingent upon the water service lines being located and the cleanout to the disposal field either being located or a new one installed as soon as the ground unfreezes. Sincerely, G~n Turner E~r~ronmental Scientist 1200 LU~$I 33roi Aue,uc. SuJl¢ ~ ,, Ancheraqe. Alosk 99503 .(907) 561-5040 ALASKA ENVIRONMENTAL CONTROL SERVICE~NC. 120o west 33rd Avenue ,~uite B ANCHORAGE, ALASKA 99503 Phone 276-1361 SHEET NO SCALE OF s^T~ ~/~/~ DATE DEPT. OF ENVIRONMENTAL CONSERVATION BILL SHEFFIELD, GOVERNOR Telephone: (907) Address: 3-5-84 To whom it may concern: Valli-Vue #2 L9, B6 PWS ID# 210605 The Valli-vue Drinking Water System (Class A) is currently in compliance with State of Alaska Drinking Water Standards. Jam~s F. Hayden ~ Environmen'tal Field O~ficer A~ch Western District ALASKA eiiUIROFImEDTAL CONTROL ~nqinceHnq 6 ~nuironmcnlal S IqulCt $, InC. MARCH 5 1984 LYM-~N KING SRA BOX 36F ANCHORAGE AK 99516 SELLER - BARBARA FORESTER BUYER - SUBDIVISION - VALLI VUE 2 BLOCK - 6 LOT - 9 ADEQUACY TEST FOR SEWER SYSTEM THE TYPE OF ABSORPTION SYSTEM IS A SEEPAGE PIT WITH AN AREA OF 828 SQFT. THE SYSTEM IS CAPABLE OF ACCEPTING 450 GALLONS OF WATER PER DAY. THE SURGE CAPACITY OF THE SYSTEM IS 1000 GALLONS. BASED UPON THE TEST DATA THE SYSTEM IS ACCEPTABLE FOR A 3 BEDROOM HOME. THE SEPTIC TANK WAS PUMPED ON FEB 29 1984 . SEPTIC TANK ADEQUACY THE EXISTING SEPTIC TANK VOLUME OF 1000 IS ADEQUATE FOR THIS 3 BEDROOM HOUSE. 1200 LUest 33rJ Auenue, ~uite [~,Anchora§e, ^l,sko 99503-/907) 561-5040