Permit Number:
Tax Code Number:
Work Type:
On-Site Wastewater Disposal System Permit
OSPl11323
01531149000
Septic
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
U pg rade
Permit Effective Dates: November 08, 2011 to November 07, 2012
Design Engineer: FLATTOP TECHNICAL SERVICES
Subdivision: VALLI VUE ESTATES #2
Site Legal Address: VALLI VUE ESTATES #2 BLK 6 LT 14 G:2539
Owner/Address: TOWER FAMILY TRUST
TOWER JOHN C & ZAFREN CHRISTINA TOWER / 6761 ROUND TREE DR ANCHORAGE AK 995166818
Site Mailing Address: 6761 ROUND TREE DR, Anchorage Lot Size in Sq Ft: 24954
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with: 1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By '/' /'.~ /
Date: i ~ ///'////,
.ate:
MUNICIPALITY OF ANCHORAGE
Community Development Department-- e~~.~ ,,,,,
Development Services Division
On-Site Water & Wastewater Program
Mayor Dan Sullivan
Phone:907-343-7904
Fax:907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. O,
Property owner(s) ~/~ ,";.r ~,~c,,.~,.~ Day phone
Mailing address I
Site address
· Legal description (Sub'd., Block & Lot) Lo t'
Legal description (Township, Range & Section)
'Lot Size _Sq. Ft.
THIS APPLICATION IS FOR:
([~ all that apply)
Absorption Field []
Septic Tank []
'Holding Tank []
Privy []
Private Well []
Water Storage []
Number of Bedrooms
THIS APPLICATION IS AN.'
Initial []
Upgrade []
Renewal []
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal Codes.
iSignature of property owner or authorized agent)
Permit/Rush Fees: ,~-.~ ~
Date of Payment:. i1'- ~'-~
Receipt Number:_ 01~-~'(~
Permit No. C~S ~
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
G:\Building\On Site\Forms\Client Forms\Permit App_010411 .doc (Rev. 1/11)
FLATTOP TECHNICAL SERVICES
CIVIL & ENVIRONMENTAL ENGINEERING * ENERGY CONSERVATION & ANALYSIS
TED MOORE, P.E.
PH.IFAX: (907)345-1355
E-Mail: tgmoorei~gci.net
M.O.A. DSD
P.O. Box 19-6650
Anchorage, AK 99519
November 3,2011
14530 ECHO CANYON ROAD
ANCHORAGE, AK 99516
Dear Sirs:
The purpose of this letter is to provide the required design narrative in support of our application for a
permit to upgrade the wastewater disposal system serving the existing 4-bedroom residence on Lot 14,
Block 6, Valli Vue Estates, Unit #2, located at 6761 Round Tree Drive. The existing soil absorption
presently appears to be operating in a surcharged condition. A site plan, design drawings and
specifications and soils log are enclosed for your review. I noticed that the Muni CAMA site
erroneously classifies the house as a 5-bedroom residence; so I informed the owner, and she is in the
process of getting the Municipal appraiser to reclassify the home as a 4-bedroom residence.
Test hole #1 was dug to a depth of 20 feet on 10/27/2011 to evaluate soil conditions relevant to the
design of the soil absorption system upgrade. A stratum of clean gravelly sand was encountered
between 3.5 feet and six feet, and again from 10 feet extending down to the bottom of the test hole at 20
feet. No groundwater was encountered or observed after 7 days of monitoring. The percolation test
demonstrated that the native sand percs significantly faster than 1 minute per inch, which is typical for
clean sand. This material will provide excellent wastewater filtration and treatment. I believe that the
appropriate absorption surface sizing criteria for this type of material should be 1.2 gpd/sq, ft, which for
a 4-bedroom residence yields a required trench sidewall area of (4 x 150)/1.2 = 500 square feet.
In order to optimize the effective trench sidewall area in contact with the sand stratum I have designed
the trench bottom to be at 14 feet below ground level and the pipe invert at 3.5 feet below ground level.
This means that the total gravel depth below the pipe invert will be 10.5 feet, but I have not counted the
4 foot thick stratum of silty gravel encountered between 6 and 10 feet below ground level. Thus, the
effective sidewall height is 6.5 feet on the uphill side, and a little less on the downhill side of the trench.
Using a conservative average sidewall height of 6.25 feet, this proposed 48-foot long trench will have a
total effective absorption area of 6.25 x 2 x 48 = 600 square feet.
The proposed upgrade is not expected to have any significant impact on present or future water supply
and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on
reserved space-surface and subsurface, or on drainage. Please give me a call at 345-1355 if you have
any questions on this submittal.
Sincerely,
Ted Moore, P.E.
L13, B6
SEPTIC
AREA
L18 B6
RETAIN EXISTING
CONCRETE RING -
SEEPAGE PIT
.,-'" SEPTIC
.../ AREA "-,
INSTALL DBL. C.O
& BULL RUN
DIV. VALVE ..~;
15%
SEPTIC
AREA
L17 B6
NEW
LONG SOIL ABS
TRENCH w. 11' TOTAL
DECOMMISSION
~ 1250 G.
SEPTIC TANK
INSTALL NEW
L16 B6
SEPTIC
AREA
L15 B6
,"- SEPTIC TANK
SEPTIC
/
/ SYSTEM
/
o
LOT 14, BLOCK 6
VALLI VUE EST. #2
-- WATER SERVICE LINE
ROUND TREE DRIVE
NOTE:
ALL LOTS IN VALLI
VUE S/D ARE SERVED
BY A COMMUNITY
WATER SYSTEM.
THE CLASS "A" WELL
IS 200'+ FROM THE
SUBJECT LOT
LOT 14, BLOCK 6, VALLI VUE ESTATES, UNIT ~2
SEPTIC SYSTEM UPGRADE
SITE PLAN
FLATTOP TECHNICAL SERVICES 1 INCH = 50 FEET
14530 ECHO CANYON ROAD DRAWN BY TFM
ANCHORAGE, ALASKA 99516 NOVEMBER, 2011
NOTE: THIS IS NOT A SURVEYED PLAT.
ALL LOCATIONS SHOWN ARE APPROXIMATE.
"A" M~ONITOR TUBE
48
EXISTING SEEPAGE PIT MONITOR TUBI
CONSTRUCT NEW 48-FOOT LONG
SOIL ABSORPTION TRENCH w.
10.5' SEWER GRAVEL BELOW
HORIZ. DISTRIBUTIONPIPE
FROM NEW
FDN. C.O.
PLAN VIEW
SCALE 1 '" = 10'
CLEANOUT
MONITOR TUBE
MOUND BACKFILL 6"
ORIGINAL GROUND
FILTER FABRIC
4" DIA. D-30~ OR F-810
PERFO~TED DIST. PIPE
1/2" - 2 1/2" SEWER G~VEL --
BOTTOM OF EXCAVATION
CONSTRUCT 48-FOOT LONG
SOIL ABSORPTION TRENCH
w. 11.0' TOTAL SEWER GRAVEL
CROSS~ECTION "A - A"
SCALE: 1" = 5'
C.O.
INST~L "BULL RUN"
DIVERTER VALVE
DBL. C.O.
INSTALL NEW
1250-GALLON
SEPTIC TANK
14
10.5 11
LOT 14, BLOCK 6, VALLI VUE ESTATES #2
SEPTIC SYSTEM UPGRADE
PLAN AND CROSS-SECTION
FLATTOP TECHNICAL SERVICES
14530 ECHO CANYON ROAD
ANCHORAGE, AK, 99516
SCALE: AS SHOWN
DRAWN BY: TFM
NOVEMBER, 2011
TEST HOLE # 1
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
FLATTOP TECHNICAL SERVICES
14530 ECHO CANYON ROAD
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
Lot 14. Block 6. Valli Vue Estates. Unit
October 27, 2011
Chris Zafren. executor for Dr. John Tower
DEPTH --
(feet)
GM Fill material
Pt. original organics
SM Reddish sandy loam
GM Silty gravel
SP Clean gravelly sand
some cobbles
same as lower stratum
GM/ML Very silty gravel
Dense, few cobbles
SP Clean gravelly sand
some cobbles
Same as upper stratum
More rounded cobbles
nearer to bottom
SLOPE
Depth to Groundwater Date
No groundwater 10/27/2011
Monitor tube dry 11/3/2011
SLO~
SITE PLAN
19
Date Reading Clock Net Time Percometer Net Drop
Time (minutes) Reading (inches)
10/27 5-gallon presoak 12:39:20 24
12:40:20 I 17 1/2 6 1/2
Re-soak 12:45:25 27 3/4
12:46:25 I 21 3/4 6
12:47:25 I 18 1/4 3 1/2
Add water 12:48:10 26
12:49:10 I 21 5
12:50:10 ! 17 3/4 3 1/4
COMMENTS:
PERCOLATION RATE <<1 (minutes/inch) PERC HOLE DIAMETER 6"
TEST RUN BETWEEN 4.75 FT AND 5.25 FT
The sandy strata perc at significantly faster than one minute per inch. Use 1.2 gpd/sq, ff. for design of abso .rption system,
PERFORMED BY FLATTOP TECHNICAL SERVICES.
Ted Moore
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.
CERTIFY THAT THIS TEST WAS PERFORMED IN
DATE: I! / ~' / ~,.o It
o~lattop TeclinicalServices
14530 ~Eclw Canyon POad, AncboroOe, AK 99516
Phone (907) 345-1355
Lot 14, Block 6, Valli Vue Estates, Unit #2
6761 Round Tree Drive
Wastewater disposal system upgrade
Specifications
1.0 General:
1.1 The scope of the project consists of decommissioning and replacing an existing 1250-gallon
septic tank and constructing a 48-foot long soil absorption trench with 10.5 feet of sewer gravel below
the horizontal distribution pipe (total gravel depth = 11.0 feet).
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform to Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work
around any buried utilities.
1.4 Unless agreed otherwise, the contractor shall be responsible for any tree clearing and
grubbing necessary to complete the project.
1.5 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.6 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading
after the soil is compacted, and seeding all areas disturbed by the construction.
2.0 Septic Tank:
2.1 The existing 1250-gallon, steel septic tank shall be properly decommissioned per code.
2.2 A new 1250-gallon Municipally approved septic tank shall be installed closer to the house
in the general location indicated on the site plan.
2.3 All pipe connections to the tank shall be equipped with waterproof mechanical couplings.
2.4 A double cleanout shall be installed in the discharge line downstream of the septic tank, as
well as a "Bull Run" diverter valve allowing future reconnection to the existing concrete ring seepage
pit.
3.0 Soil absorption system:
3.1 The soil absorption system shall be constructed by excavating a 14-foot deep by 48-foot
long trench, as shown on the site plan and design drawings.
3.2 The bottom of the trench excavation should be level.
3.3 A total of 11.0 feet of sewer gravel shall be placed in the trench excavation with the
perforated distribution pipe laid level such that the pipe invert is no less than 10.5feet above the bottom
of the sewer gravel.
3.4 The distribution pipe shall be 4" diameter ASTM F-810 or D-3034 perforated pipe.
Monitor tubes and cleanouts shall be of 4" diameter and installed in the locations shown on the design
drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel, prior to
backfill.
3.6 The backfill shall be mounded a minimum of 6 inches above original ground level.
3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to
have the site finish graded after the backfill material has stabilized, and for placement of adequate seed
to promote rapid revegetation.
4.0 Inspections:
4.1 A minimum of 4 engineering inspections will be required during the course of the project:
(1) initial stakeout with the contractor to establish the location of the system and to discuss the plans,
specifications and construction procedures, (2) after the native material has been excavated to expose the
infiltrative surface to ensure that it conforms with the soil test information, (3) after the sewer gravel is
in place and the distribution pipe has been laid and connected up to the septic tank, but prior to
placement of filter fabric, and (4) after roUgh backfill and grading is complete. The septic tank
installation inspection shall be in conjunction with one of the other listed inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far
in advance to ensure the availability of the engineer.
~GRE ER ANCHORAGE AREA BOL ~JGH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPO
NAM~)~ : ...... UlSPOSAL SYSTEM
........ MA'L'NG^DDRESS
LOCATION~
SEPTIC TANK:
DISTANCE /'~0/~q D/
FROM WELL (...,>'u ~/,'~/~.
~MANUFACTURE~/~ MATERIAL~ NUMBER OF
-COMPARTMENTS
INSIDE LENGTH~ . INSIDE WIDTH~
~ LIQUID DEPTH~LiQUiD CAPAC/TY/~
SEEPAGE PIT:
GALLONS.
NUMBER OF PITS ~. DIAMETER ~
LINI /~/Z/Z. ~:Z"~ ~ OR WIDTHs, LENGTH~, OEPT' 'z/~' /
NG MATER,AL ~%~Z,,B S,~E: //~/'
DIAMETER'~ DEPTH ~iSTANCE
BUILDING FOUNDATION NEAREST LOT LINE~/~ TOTAL EFFECTIVE '
~ · ABSORPTION AREA (WALL AREA~ SQ. FT.
ADDITIONAL ABSORPTION
- CONSTRUCTION
BUILDING
NEAREST
FOUNDATION ~, LOT LINE_
CESSPOOL ~,
OTHER SOURCES
APPROVEO~ DISAPPROVED
~ REMARKS_
NEAREST
SEWER LINE~,
-- DEPTH
SEPTIC
DISTANCE FROM:
SEEPAGE /~ ~
SYSTEM~
DISTANCES:
1EMARKS:
DIAGRAM OF SYSTEM
DATE
'ROVED
GREATER ANCHORAGE ArEA BOROUGH
DEPARTMENT OF" ENVIRONMENTAL QUALITY'
3330 "C" STREET ANCHORAGE, ALASka 99503
TELEPHONE 274-456 !
SEWAGE DISPOSAL SYSTEM __ APPLICATION AND PERMIT
INSTALLATION LOCATION ~1~ ~J~Z __ MAILING ADDRESS ~~
FINANCED THROUGH .
IEPTIC TANK TO SEEPAGE PiT WALL /~'~ (
EPTIC TANK ~, SEEPAGE PIT .J~J~_ DRAIN F,ELD
ELL TO SEPTIC TANK ~) r
~, SEEPAGE p~T ~ ~ ~
PTIC TANK ~O ~ ~ ~
' ~, SEEPAGE PIT (~' . DRAIN FIELD
TO RIVER, LAKE. STREAM,
DIAGRAM OF
IRTIFy THAT I AM FAMILIAR WITH THE REQUIREMEN
3201Spenard Road
Anchorage,Abska 99503
(90~ 272-2407
WOODWARD- LUNDGREfl & ASSOCIATES, INC.
August ZO, 1973
Job No. A12%09-14
Falcon Masonary Construction
P.O. Box 41513
Anchorage, Alaska 99509
Gentlemen:
Test Pit Excavation
Lot 14, Block 6
Valli~Vue Estates
Anchorage, Alaska
At your request, the undersigned inspected the subject exca-
vation and logged the vertical soil profile on August 10, 1973.
A sketch of our unde.rstanding of the proposed development is
shown as Figure 1 and the soil profile of the excavation is
shown in Figure 2.
The soils were visually classified and absorption values
signed accordingly on the basis of our experience and by written
guidelines of the Greater Anchorage Borough. Absorption values
are given under "Remarks" in Figure 2.
If we can be of any further service to you, please call.
Very truly yours,
WOODWARD-LUNDGREN & ASSOCIATES
Rodne~P. Kinney, P.E.
· Chief Engineer
RPK:nck
cc CAKE, DEQ
Atten. Sue Dikerson
OAKLAND SAN JOSE SAN FRANCISCO ANCHORAGE, ALASKA
N
,160
~ROUND' TREE DCClVE ~
$1"TE PLAN - FI(~U~'E I
AppROX. SCALE; 1"-30'
NOTE; TAKEN Ft~O M'A GC,C,,/HOK PLAN
DA T E D
WOODWARD-LUNDOREN & ASSOCIATES
ii, ;~{ ~ ,_ 0 ~ ~ ~ ~ ....
Consulting Soil Engineers
SAMPLE 'DESCRIPTION,
color~ moisture, p~rticle
size, consistency
~.EOuJ~J J'/~ ~'
and Geologists
/7,~' ~t. _ .
C' :::..
6eologist /'~ ~
(drilling of
casing, casing bio,rs
fluid loss, bi~ cond -
tion~ crowd~ rprn~ e~c.)
~'/~ -85
FIG, 2
;~' = Ol
i.
3330
R~(,~IVED
GREAT£R ANCHORAGE ARE,S gOROUGH
Department of Environmental QualitySEP
"C? st., Anchorage, Alaska 99503
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
1. Type of Inspection: CMRO VA FHA CONV
2. Property Owner: 3ohn C. Tower, M.D. & Elizabeth A. Tower,
XX
Mailing Address: 3300 Providence Dr., Anch. D~Z Phone 279-6461
3. Name of Buyer: same
Mailing Address:
4. Name of Lending Institution:
Mailing Address: Box 4-2090 (99509)
5. Name of Realtor or Agent: - - - -
Mailing Address:
Da_~y Phone
The First National Bank of Anchorage
Phone 274-1521
Phone
Legal Description: .Lot 14~ Blk. 6, Valli Vue Estates Unit No. 2
Location: 6761 t~ound Tree Drive, Anchorage
7. Type of Facility to
8. Water Supply
Type of Supply:
If Individual,
be i ns pected Single Family Dwell~.~-~
: Bdrms.
Public Utility ×X IndiVidual
number of dwellings presently .served
If Individual, depth of well
Sewage Disposal-System
Type.of System: Public Utility
If Individual, date of installation
Individual (on-site)
4