Municipality of Anchorage
On-Site Water and Wastewater Section • (907) 343-7904 Page of
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP221178 PID Number: 015-123-27
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade
Name
VERAL & JUDITH STOCKTON
ABSORPTION FIELD - EXISTING
❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
6840 CROOKED TREE DRIVE, ANCHOREGE
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
3
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
VALLI VUE ESTATES #2 6 25
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
FtZ
Ft.
Well
200'+
__
25'+
TANK ® Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREER
Capacity
1500 Gal.
Surface Water
100'+
--
Material
HDPE
Number of compartments
2
Lot Line
10'+
__
NA
Foundation
10'+
ILIFT
STATION
Manufacturer
Capacity
Gal.
Remarks Tank insulated. 3BR HOUSE — 1500 GAL S.T.
installed for current functionality & future flexibility.
Alarm location
Electrical installed by
Installer NORTHERN EXCAVATION
PIPE MATERIAL House to tank 3034 d ainfie d 3034
Drainfield CO/MT 3034
Inspector FWC
BENCH MARK (Assumed elevation) 100 ft
Inspection 1" 2/15/23Location
dates: Z d 2/16/2023
and description
3rd 4th
BOTTOM OF SIDING
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
2401`�,,
-qb
OF X11
Conditional Approval: Date
..... Q� Vo
e(b IF
.. 49- ....�..
�� • •
Septic System
Curtis Huffman
Approved -
�� �'Fc •, CE 128991
Date Z 2.a WZz
}��J'���.•2/24/2023. ��
�
k,F�pROFESSI�HP -�
�
Note: this approval does not include well permit requirements.
�
kRev 05102n6)
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
February 24, 2023
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: VALLI VUE EST. #2 B6, L25 – EXISTING FIELD TO FOUNDATION WAIVER
Due to limited site constraints, the existing aged steel tank was removed, properly
decommissioned and a new 1500-gallon HDPE tank installed in the same location. Per the
septic tank upgrade permit the existing field was located to verify 5’ separation to the
newly installed septic tank and a field cleanout was installed to the start of the trench. It
was discovered at excavation that it appears this existing septic field is within 10’ of the
existing foundation and has been for the past 30 years without any known issues or
adverse impacts.
Granting of this waiver is justified because there have been no known or observed adverse
impacts for 30 years of any effluent interaction to the foundation. The MOA has approved
the existing inspection report and subsequent COSAs of this property. This appears to be
the closest portion of the 5’-wide trench to the foundation slab. The slab foundation is the
garage with no living area impacts. The field invert is approximately 4’ below the bottom of
this foundation garage area. The area has good compactable soils and no known
groundwater issues. There has been no known settling or point load issues and the
porosity of the soils indicate minimal if any lateral migration. We believe that separation is
adequate to prevent any potential damage to the building or drain field per record
documents and visual observations. We are unaware of any adverse impacts this waiver
would have to the existing drain field or foundation.
Given this justification, we respectfully request a 3’ existing field to foundation waiver be
granted at this time. Granting of this waiver will not impact any of the neighboring
properties. Please contact us if you have any questions.
Sincerely,
Curtis Huffman, P.E.
licn
Municipality of Anchorage
P.O. Box 196650 • 4700 Elmore Road
Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997
http://www.muni.orq/Onsite
Development Services Division
On-Site Water and Wastewater Program
* * * * VARIANCE/WAIVER REVIEW * * * *
Waiver#: OSV231007 COSA#:OSC231044
PID#: 015-123-27
Legal Description: Valli Vue Estates #2 Block 6 Lot 25
Engineer: Curtis Huffman
Your request for a waiver of the required 10 feet horizontal separation from the absorption field to
the foundation has been approved. The approved separation distance is 3.0 feet.
This waiver approval applies to the proposed absorption field. Any future upgrade to the on-site
wastewater disposal system will require all separation distances be met or another approval from
this department.
Waiver is Granted: X Waiver is not Granted:
Date: Z Z 2OZ
Approved by:
Name of Reviewer
**** VARIANCE/WAIVER REVIEW ****
PID:015-123-27 PERMIT:OSP221178
FIRST WATER CONSULTING
VALLI VUE ESTATES #2 BLK 6 LT 25
// \
/ / /
Lot 23
10' UTILITY EASEMENTS
NOTES
1) DUE TO SNOW & ICE COVER,
SOME SURFACE LEVEL
FEATURES ARE APPROXIMATE.
2) THE LOT IS SERVED BY A
COMMUNITY WATER SYSTEM.
PLOT PLAN AS BUILT _X SCALE GRID —40-_ GRID _ SW 2539Project No. -----L3=25.0/L1----
11500 & Associates, n C (907) Daryl Avenue, Anchorage, Alaska ="`-3049
(907) 522-6476 Phone
kenOlongsurvey.com ��
Professional Land Surveyors jonothanOlangsurvey.com ?�OFAt,9`ll
trovisOlangsurvey.com e'�, • •' • •, �,
I hereby certify that I have surveyed the following described property:
LOT 25, BLOCK 6, VALLI VUE ESTATES — UNIT No. 2 (PLAT No. 77-296)
Anchorage Recording District, Alaska, and that the improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
no improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on said property except as indicated hereon.
Dated this the "✓`'""�'' �c.V1,0''"I'll
�__ Day of 1_.___at Anchorage, Alaska
It is the responsibility of the owner to determine the existence of any easements,
covenants, or restrictions which do not appear on the recorded subdivision plat.
48TH *I
y , KENNETH G. LANG
,N 5,402 �Q�
��
%l "
,1 9FDP' • .. (.'. • SSSAW
!OFESSIONN� P
State of Alaska AECC963
MUNICIPALITY OF ANCHORAGE nr
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 r�
http://www.muni.org/onsite V u
Depai-tment
On -Site Wastewater Disposal System Permit
Permit Number: OSP221178 Effective Date: 2/2/2023
Work Type: SepticTank Upgrade Expiration Date: 2/2/2024
Tax Code Number: 01512327000
Site Legal Address: VALLI VUE ESTATES #2 BLK 6 LT 25 G:2539
Site Mailing Address: 6840 CROOKED TREE DR, Anchorage
Owner: STOCKTON VERAL E & JUDITH T Lot Size in Sq Ft: 20532
Design Engineer: FIRST WATER CONSULTING Total Bedrooms: 3
This permit is for the construction of:
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
1. Locate the beginning of the field prior to installation to confirm that the 5' separation between the tank and
field will be met. Install a cleanout so the field can be located in the future.
2. The water service line is to be located and shown on the record drawing.
i
-ReGefved=EPj,: _ .1 5su e
Issued By:
Date:
Date: Z Z 2y
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 015-123-27
Property owner(s) VERAL & JUDITH STOCKTON Day phone
Mailing address 6831 ORCHID DRIVE, SALCHA, AK 99714
Site address 6840 CROOKED TREE DRIVE, ANCHORAGE, AK 99507
Legal description (Sub'd., Block & Lot) VALLI VUE ESTATES #2, B6 L25
Legal description 20 (Township, Range & Section)
. __ ..
Lot Size 532Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) El
(w/wo AD U)
Septic Tank
0
Upgrade 0
(D) El
Holding Tank
❑
RenewalDuplex
❑
Multiple Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION
INCLUDES
A WAIVER REQUEST FOR:
Distance:
certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 4225 Waiver Fees:
Date of Payment: �0Z3/a4,� ), Date of Payment:
Receipt Number: 36ZQ 7 Receipt Number:
Permit No. 17S Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
June 10, 2022
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC TANK UPGRADE PERMIT
LEGAL: VALLI VUE ESTATES #2 B6, L25
The owner has requested that we obtain a septic permit to upgrade the existing aged steel septic
tank on the above referenced lot. We propose to install a 1000-gallon HDPE tank per the
attached design to serve the existing 3-bedroom residence. The lot and area are served by public
water / Class A well. The design will not impact any of the neighboring properties. Please
contact us if you have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221178, Deb Wockenfuss, 06/28/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221178, Deb Wockenfuss, 06/28/22
) DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
( ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME PHONE ~NEW
LEGAL DESCRIPTION
LOCATION C~O KC& '~r~ NO' Of BEDROOMS
l Well ~ Absor~t~n area Dwelling ~~ ~n' ~
DISTANCE TO: ~0~ ~D ~ (~
Manufacturer ~ Mat0rial~ [ No. of comoartments
~ ~ DISTANCE TO: Well Dwelling PERMIT NO.
O z ~ Manufacturer Material Liquid capacity in gallons
PER T NO
O Well Foundation Nearest lot line~ ~
OTHfi8
pvc
v 'H~ 0
· MUNICIPALITY OF ANCHORAGE
~ ~ ~, Department,~ Health and Environmenta]~lrotection
.? ? 825 ~ Street, ~nchorage~ AK. J35UI .' ~1~ ~
264-4720
~ ?,'~O~S~ * * * HANDNRITTEN PERMIT * * * ~:~l~-~:-~...~
Permit # ~ ON-SITE 'SEWER PERMIT
.t
Location: Phone Number: ~,7~--':~'~ ~
~TYpe of Soil ~sorption System
~ Trench: ~ Drainfield. Seepage BeC~ Holding Tank:
M~imumX N~ber of Bedrooms.-- ~ Soil Rating(sq.ft/br) /~D
The Required Size of the Soil ~sorption System Is:"
~EPTH t~ LENGTH ~ :~ GRAVEL DEPTH ~ W~DTH
The length dimension is the length(in feet) of the trench or drainfield. The
~epth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in fee~). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
· * REQUIRED SEPTIC(HOLDING) TANK SIZE= /~ GALLONS
Pe~it applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this p~operty and the nu~er
of residences that the well will serve.
· * * TWO(2) INSPECTIONS ARE REQUIRED ~ ~ ~
Backfilling of any system without final inspection and approval by this department
will be subject to prosecution.
Minimum distan'ce between a well and any on-site sewage disposal system is 100 feet~
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minim~ distance from a private well to a private sewer line
is 25 feet and to a co,unity sewer line is 75 feet. Well logs are required
an~ must be returned to this d~partmen.t within 30 days of the well completion.
Other requirements may apply. .Specifications and construction diagrams are
available to insure proper installation.
· * * PERMIT EXPIRES DECEMBER 31, 1 9 g 3 * * *
I certify that:
(1) I ~ f~iliar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the residence is remodeled to include more that~ bedrooms.
SigneR: . ~__ Issued
, App,'cant Date:
SWP/024(1/81)
'tmzt ~ - ,, ~ ~ ON-SITE $~WER PERMIT ~- ~ -~'
~al De,trip%ion: i~l Size:
~pe of Soil ~sorp~ion System I~~~--~
~'~neh; _~ Dratnfield~ ~ Beepage Bedj - ~ Holding Tank: ~ -
· he ~e~tred Size of the Soil ~,sozption System
ihe lengkh dxmens, on i~ the length(~n feet) of the ~rench or dra.znf~eld, The
~pth of a trench or pit is the distallce between the surface of the ground and
~he bottom of the excavatlon(i~~ ~ feet). There is no ~et width for trenches,
fSe gravel depth is the minim~ depth of 9ravel between the outfall pipe and
,~h8 ~ttom of the ~xoavation{in feet.).
~ ~ REQUIRED SEPTIC(HOLDINg), , ~ANK SIZE = ..... . GALLONSt ~ ~
~mi% applicant ha~ khe responsxbllity %o info~ this dep=rtmen du~:ing the
zltallation i~speotions of ar{y we]ls adjacent to this pro~z'ty an~ the
~es~dences that th~ well will serve,
~ ~ * T~O(2) INSPECTIONS ARE REQUIRED * ~ ~
Lkfztlzng of any myst. em without, final inspection and approval by this deparkmer
i'1 ~ subject to
i~o~ Bi,tahOe between a well and any on-site sewage disposal system is !00
8 p~vat.~ well or 150 %o 200 feet f~om a public well dep~hdinq upon the type
'.pubt~,c well, Minimum dimtance from a private well to a privake s~wer line
i~5 feet and to 8 gommunity ~ewer line is 75 feet. well logs are r~quired
I must be r~turnt~ to this deEattm~nk within 30 days of tbs well completion
'
~er requiremer~t~ ~zy apply. Speoifioat$ons and constroction dxagram~, are
~t!able tO insure proper in~tallatioo.
~ ~ { P~RMll' EXPIRtS DECE~ER 51~ 1 9 8 3 * ~ ~
[ certify that:
(1) ~ ~ f~iliay with the requirements for on-site s~wers add wells as
Set forth by th~ M~-~icipality of ~{oho~age.
(2) I will install the system in aecordano~ with c~es,
(3) X under~kand thak the on-s~te sewer system may require er~largemenl if
· ' ~ t hat/.~ bed room~4,
S~gne' ' ~: l~sued by ~
Date: .........
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L, Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
SOILS LOG ~'
[] PERCOLATION
TEST ': '
3-
8
9
10
11
12
13
14
15
16
17
18
19
20
SLOPE
ENCO NTE"E ? O
E
IF YES, AT WHAT ~
DEPTH?
SITE PLAN
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE
TEST RUN BETWEEN
COMMENTS
PERFORMED BY: -~'~'~ ~(,~-'~ CERTIFIED BY:
(minutes/inch)
FT AND __ FT
72-008 (6/79)
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 015-123-27
Certificate of On -Site Systems Approval
2 -
Expiration Date: 2 11
Legal description VALLI VUE ESTATES #2 BLK 6 LT 25
Site address 6840 Crooked Tree Dr Anchorage
Current property owner(s) Veral and Judith Stockton
X The On-site system(s) is/are approved for 3 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
M
Original Certificate Date: 2/27/2023
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approva"une 2022
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 015-123-27
Complete legal description VALLI VUE ESTATES #2 BLOCK 6, LOT 25
Location (site address) 6840 CROOKED TREE DRIVE, ANCHORAGE, AK 99507
Current property owner(s) VERAL & JUDITH STOCKTON
2. ON-SITE SYSTEMS SIZED FOR 3 BEDROOMS
Day phone
3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ® Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ® Plastic ❑ Concrete ❑ Fiberglass
Age 0 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ® Deep Trench ❑ Wide Trench ❑ Seepage Pit
3,
Waiver request for: EXISTING FIELD TO FOUNDATION Distance:._
Expedited review requested: ❑
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $
V1@
Date of Payment a Y/ 01)e
COSA# OSC/ (Irl
6--7q �z35—
Waiver Fee $ 7S�
Date of Payment
Waiver # Vea
COSA Application.doc
COSA Checklist.docx
COSA Checklist
Legal Description: VALLI VUE ESTATES #2 BLOCK 6, LOT 25 Parcel ID: 015-123-27
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA - PUBLIC &/OR CLASS “A” WATER
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank NA
Date of pumping NA – NEW TANK
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 8/18/1983
ALL standpipes present per record drawing
Total measured depth from grade 9 ft (max)
Measured depth to pipe invert from grade 5.5 ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes go to bottom of effective.
If not, state depth into effective 3.5’ OF 5’ED
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 5/4/2022
Results Pass
Fluid depth prior to test 1 in
Water added 750 gal
New fluid depth 5 in
Elapsed time 1440 min
Final fluid depth 0 in
Absorption rate 450 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 60 in
Effective depth used 18 in (MISSING ED)
Effective depth remaining 42 in
Comments/Deficiencies: Measurements taken show approximately 3.5’ of the 5’ ED MOA inspection report (IR). Field
appears to be working at and below the bottom of the existing MT/Sump, which was missing approximately 18”. Field
pipe was jetted and cleaned in 2/2023.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No *3’+ ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
*Waiver submitted with this COSA application – 3’ separation to existing foundation to field.
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 2/24/2023
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
2/24/23
MUNICIPALITY OF ANCHORAGE
Department of Health & Human Services
DIVISION OF ENVIRONMENTAL SERVICES
343-4744
Parcel I.D. #
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF
ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING
1. GENERAL INFORMATION (Must be completed prior to submittal)
(a) Legal Description (include lot, block, subdivision, section, township, range)
Lot 25; Block 6; Valli Vu~ Estates ~2
Location (address or directions)
6840 Crooked Tree DrZve
(b) Property owner
Mailing Address
(c) Lending Institution
Mailing Address
A1 Be~tgstrom Telephone: (home) 346-3801 Business 562-6186
6840 Crooked Tree Drive, Anchora.~e, Ak.
Telephone
Jack White Company ATTN: Dale Murphy
(d) RealEstate Company and Agent
Address 5201 C Street
Telephone 563-5500
Suite 100
Anchoraqe, Alaska 99503
· (e) Mail the HAA to the following address: (or check here I~'¢ if hold for pick up.)
List contact person and day phone number below:
$ & S ENGINEERING
1703-* Eagle R~ver Lo~I~ Road No. ~
Eagle River, Alaska 99577
2. TYPE OF RESIDENCE
Single-Family E~x' Number of bedrooms $ ....
3. WATER SUPPLY
Individual Well [] Community ~ Public []
Note: If community weld system, must have written confirmation from the State Department of Environmental
Conservation attesting to th legality and status·
4. SEWAGE DISPOSAL
On-site~ Public [] Community [] Holding Tank []
Note: If community well system, must have written confirmation from the State Department of Environmental
Conservation attesting to the legality and status.
72-025 (Rev. 7/88) Page 1 of 2
5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this
Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe,
functional .and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and
State codes, ordinances, and regulations in effect on the date of this inspection.
Name of Firm ~ ~ S ENGINEERING
17034 Eagle River Loop Road No, 204
Address Eagle ~,[yer, Alaska 99577
Date
Telephone
6, DHHS APPROVAL
Approved for_~--~ bedrooms by
Approved ~.~ _._ Disapproved
Terms of Conditional Approval
Conditional
~ ' ............... IF TI ,f;T,all[flgF--- I1
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval
cerificated based only upon the representations given in paragraph $ above by an independent .p_rofessional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections
or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or om issions
in the professional engineer's work.
A. WELL DATA
Well ClassificatiOn
MUNICIPALITY OF ANCHORAGE (MOA)
Health Authority Approval (HAA)
CHECKLIST - FEBRUARY 1984
343-4744
Legal Des~/ription:
If A, B, C, D.E.C. Approved (~N) ~
Well Log Present (Y/N)
Total Depth Cased to
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
SEPARATION DISTANCES FROM WELL:
To Septic/Holding Tank on Lot
To Nearest Edge of Absorption Fieldon Lot
To Nearest Public Sewer Line
To Nearest Sewer Service Line on Lot
Water Sample Collected by
Water Sample Test Results
Comments
Date Completed Yield
Depth of Grouting
Pump Set At
Sanitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
; On Adjoining Lots
; On Adjoining Lots
To Nearest Public Sewer Cleanout/Manhole
; Date
B. SEPTIC/HOLDING TANK DATA
Date Installed ~"f(:~" ~"~ Size
Standpipes ~'N) y
Depression over Tank (Y~'
TO Water-Supply Well
To Property Line
To Water Main/Service Line
[, ~ No. of Compartments ' ~-
Air-tight Caps~:~'q) 7 Foundation Cleanout(~N)
r~ ..Date Last Pumped /C~ - ) ,~,-- '~::~'
'~//~- ;for
Pumping/Maintenance Contact on File (Y/Ni~/~
Holding Tank High-Water Alarm (Y/N) Temporary Holding Tank Permit (Y/N)
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK:
To Building Foundation
To Disposal Field ~ ~
To Stream, Pond, Lake or Major Drainage Course \ ~
Comments A
72-026(Rev. 7/88) Front Page 1 of 2
C. ABSORPTION FIELD DATA
. /
Soils Rating in Absorption Strata
Date Installed
Width of Field ~'~
Type of System Design "~'T'~,~(-~F4
Length of Field ~
Depth of Field "~ /~, I ,,~/~,
Square Feet of Absortion Area
Depression over Field (Y~
Results of Last Adequacy Test
Gravel Bed Thickness ~ ¢
/--'~6~-~~' Statndpipes Present'CP/N)
r.--[ Date of Last Adequacy Test
SEPARATION DISTANCE FROM ABSORPTION FIELD:
To Water-Supply Well '"-Z-~~t-~
To Building Foundatio~
Lot
To Water Main/Service Line
To Property Line '~---'='1 f
To Existing or Abandoned System on
; On Adjoining Lots %f.,4-
To Cutback (if present) ~....~
To Stream, Pond, Lake, or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
Comments
D. ~,~T STATION
Size in
Gallo n~'---~ ~
"Pump On" Level at
High Water Alarm Level at
Tested for
Meets MOA Electrical Codes (Y/N)
Comments
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
~ ~.~Vent (Y/N)
ng Adequacy Test.
**Check Permitted Bedroom Rating Against HAA Request**
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in
inspection.
Signed
Company
Date
MOA NO.
S & S ENGINEERING
17034 Eagle River Loop Eoad No. 204
Date of Payment '~--~:::~/-~' ~'~
Amount: $ ,,/'~,. P~-'~.
Receipt No
Waiver Fee: $
Date of Payment
72-O26 (Rev. 7/88) Back
Page 2 of 2