HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 6 LT 33Valli Vu states lock 6 Lot 33 lrcev Uaivu 1 a/ Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 4 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP201009 PID Number: 015-123-19 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑ Upgrade Name Allen Hippler ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 6730 Crooked Tree Circle Anchorage,AK 99516 ❑ Other Phone Numb er of Bedrooms Soil Rating Total depth from original grade 907-830-9995 4 1.0 GPD/SF 2.0/2.1 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 1.5/1.5 Ft. Gravel depth beneath pipe .6/.5 Ft. Subdivision Block Lot Valli Vue Estates #2 6 33 Fill added above original grade 2.25/2.8 Ft. Gravel length 60/60 Ft. Township Range Section Gravel width 5/5 Ft. Beds: Number of Lines Distance between lines + Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer. Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 600 Ft2 2 >6 Ft. Well >100' >100' N/A N/A >25' TANK ❑o Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Greer 1,250 Gal. Surface Water >100' >100' N/A N/A Material Number of compartments Lot Line >5' >10' N/A N/A NA Plastic 2 Foundation >10' >10' N/A N/A LIFT STATION Manufacturer Capacity Remarks Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034Tank to D3034 drainfield Installer A+ Home Services Drainfield D3034 Co/MT D3034 Inspector L. Tidwell/J. Millette . BENCH MARK (Assumed elevation) 100.0 ft Inspeection 151 9/8/20 9/9/20 Location and description ction 3'd 9/10/20 2nd 4'" Bottom of siding at SW corner of Home. ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp � SOF ����� ""'`.•q## Conditional Approval: Date P•..••""" •049th ° � 't' n•• uu... a Suu.� ............................................ �� �•°°r1,fCHAEL E. ANDERSON : CE -4381 �Approved Septic System 01Y12,r,41 411'tA,0_No. Date 1 ,W ## p%.. 12/30/20 •.•°''°`S"� Note: this approval does not include well permit requirements.�������� ��OFCS51C�aP��4t� lrcev Uaivu 1 a/ EXISTING SEEPAGE PIT REMAINS IN SERVICE FOR FUTURE USE. 100500 FEET 1"=50'4-BDRM HOMECO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE FD - FLOW DIVERTER MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TH#1 PERMIT # OSP201009 PID # 015-123-19 VALLI VUE ESTATES #2, BLOCK 6 LOT 33 A B FCO 17.3 MH1 36.0 SV1 38.5 A B C C 2CO 39.7 FD1 40.3 C01 42.0 82.8 MT1 40.3 82.4 14.7 14.4 19.2 20.8CROOKED TREE CIRCLE12/3/20 1250-GAL SEPTIC TANK w/ 20" MANWAY CO3 2CO MT110' UTILITY EASEMENTCOMMUNITY WATER SERVICE LINE FD1 *THIS LOT & ADJACENT LOTS ARE ALL SERVED BY A COMMUNITY WELL. *CONTOURS ARE IN INTERVALS OF 5'. 2-60' LONG x 5' WIDE x .5' EFF DEPTH ABSORPTION TRENCHES w/2' MOA APPROVED SAND FILTER. MT3 MT2MT4 CO1 MH1 SV1 CO2CO4 FCO PLAN AS-BUILT CO2 40.2 35.8 MT2 41.5 C03 59.45 MT3 59.2 38.3 97.5 97.8 CO4 49.6 51.9 MT4 51.4 53.5 21.8 FS PROFILE AS-BUILT (NO SCALE) 97.3 92.3 97.9 101.9FCOMH1 SV1PERMIT # OSP201009 PID # 015-231-19 VALLI VUE ESTATES #2, BLOCK 6 LOT 33 12/3/202CO97.2 1250 GAL SEPTIC TANK OF.ACgl11 // E r����'• '191 / T / TH �� • •�• � Jeremy, A. urst • '0.0e L 17.96 •i tv / AIW ROffSSIONk� / IL0 it 3�3) Lot , Block (6) 4 / 49th /Stir J Surveying �0. 1s �0-1;. 3.0' R � 4 I p / 2 -Story 0 / House'q� / Conc. 0 / / Lot 34 Vol -POO, � ® A120.52' R405.00' 0 15 30 A17*03'00" US SURVEY FEET Lot 32 il� / 0 NOTES 111;F / -All dimensions shown are grid bearings and ground distances, Record boundaries are per Plat No. 71-285. -49th Star has conducted a physical survey of the property and all details shown on this Asbuilt Survey are correct. Under no circumstances should any data hereon be used for establishment of property lines. -It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. AS BUILT SURVEY LEGEND 49th Star Surveying in1;_.L_ gWater Service Valve 321 Fireoved Drive Lot 33, Block 6, 0 Septic C/0 -Vent Pipe Anchorage, AK 99508 Valli Vue Estates Unit No. 2, (907)891-6111 Anchorage, AK (S) septic Manhole Jeremy@49th5tarSurveying.com As Tele -comm Pedestal W.O. 19036 DATE: 1/20/21 ��� Electric Pedestal SCALE: 1-=30' MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PQ Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http:llavww.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP201009 Work Type: Septic Upgrade Tax Code Number: 01512319000 Site Legal Address: Vl LL -1 \Xt E ESTATE -S Site Mailing Address: �'73a Owner: RIPPLER ALLEN, Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date -'� 2 S u< (o LT --S'-,' UK CLC) AN CH Lot Size in Sq Ft Total Bedrooms: I epartmc nt 1/30/2020 1/29/2021 0(, T1 4 C,71 Disposal Field 7 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: MAW/ Issued By: Date: -) Date 30 6 MUNICIPALITY OF Community Development Department Development Services Division QD On -Site Water & Wastewater Program EP&PNS ANCHORAGE Phone: 907-343-7904 Fax: 907-343-7997 ON-SITE SEWERIWELL PERMIT APPLICATION Parcel I.D. 015-123-19 Property owner(s) Christine L. & Allen M. HipplerDay phone 830-9995 Mailing address 6730 Crooked Tree Circle Anchorage, AK 99516 Site address Same Legal description (Sub'd., Block & Lot) Valli Vue Estates #2, Block6, Lot 33 f Legal description (Township, Range & Section) Lot Size 22,677 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑X Initial El Family (SF) 1Z 1Z(w/wo ADU) Septic Tank ❑X Upgrade 0 Duplex (D) ElHolding Tank ❑ Renewal ElMultiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is! in accordance with applicable Municipal Codes. f i (Signature of property owner or authorized agent) Permit/Rush Fees: 0- ql�5- Waiver Fees: _ Date of Payment: 110`�02� Date of Payment: Receipt Number: ���Receipt Number: Permit No. %icy P 961009 Waiver No. Permit App_.;- : • :-'.,r_ PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) January 29, 2020 MOA Development Services Department On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Valli Vue Estates #2, Block 6, Lot 33 – 6730 Crooked Tree Circle Septic System Design Dear On-Site Services Engineer: The existing septic system on the subject lot has failed and must be replaced. We are submitting this permit application for the construction of a new septic system to serve the four-bedroom home on the lot. The attached site plan identifies the location of the home and the existing and proposed septic system. This lot and the subdivision are currently served by a community water system. No conflicts exist between this proposed system and any other well, water services or septic systems on this lot or adjacent lots. The ground surface on the lot slopes toward the northwest in the area of the proposed absorption trenches. There are slopes greater than 25% within 50 feet down slope of the new absorption trenches. The trenches have been designed to meet the steep slope requirements of the Municipal Code. The distribution lines are more than 3’ below the surface. Ground surface contours are shown on the site plan indicating the grade and direction of flow. Storm water drainage will not impact this septic system. The new trenches will be constructed parallel to the slope as much as possible. The Valli Vue Subdivision is served by a community well more than 200’ away. No private wells are in the area. The new system will be a minimum of 100’ from surface water and more than 5’ away from the septic tank. Please refer to the attached test hole logs and plan and profile sheets for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE 1/29/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201009, Rebecca Carroll, 01/30/20 EXISTING SEEPAGE PIT TO REMAIN IN SERVICE FOR FUTURE USE. 100 50 0 FEET 1"=50'4-BDRM HOMENOTE: SLOPES >25% ARE WITHIN 50' OF THE ABSORPTION TRENCHES. THE TRENCHES HAVE BEEN DESIGNED TO MEET THE STEEP SLOPE REQUIREMENTS OF THE MUNICIPAL CODE. NO SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE FD - FLOW DIVERTER MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND TH#1 VALLI VUE ESTATES #2, BLOCK 6 LOT 33 CROOKED TREE CIR CL E 1/29/20 DECOMMISSION EXISTING TANK IN ACCORDANCE w/ MOA CODE. INSTALL NEW 1250-GAL SEPTIC TANK w/ 20" MANWAY INSTALL 2-60' LONG x 5' WIDE x .5' EFF. DEPTH ABSORPTION TRENCHES w/ 2' MOA APPROVED SAND FILTER. CO CO CO CO 2CO MT MT MT MT10' UTILITY EASEMENT COMMUNITY WATER SERVICE LINE FD FS *THIS LOT & ADJACENT LOTS ARE ALL SERVED BY A COMMUNITY WELL. *CONTOURS ARE IN INTERVALS OF 5'. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201009, Rebecca Carroll, 01/30/20 VALLI VUE ESTATES #2, BLOCK 6 LOT 33 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: <1 MIN/IN APPLICATION RATE: 1.0 GPD/SF 5' WIDE SHALLOW TRENCH SYSTEM 1250-GAL SEPTIC TANK TYPICAL TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 5' 6" 6" 4' 6" NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 5' BELOW GRADE FLOW LINE ELEVATION: 4.5' BELOW GRADE TOP OF TRENCH: 0.5' ABOVE GRADE 600 GPD / 1.0 GPD/SF /5' WIDE = 120 LF TRENCH REQUIRED (120 LF SPECIFIED) 1/29/20 MOA APPROVED SAND GEOTEXTILE FABRIC 2' Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201009, Rebecca Carroll, 01/30/20 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) VALLI VUE ESTATES #2 B6 L33 9/13/19 J. WILLIAMS DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH? - <1 6 4 5 015-123-19 Allen Hippler 11:28 9/13/19 1 2 3 4 5 6 0 0 16 / 6 0 16 11:31 11:35 11:40 11:43 11:50 1' OB Professional Engineers Stamp: 1/23/20 2:15 NO NONE 9/25/19 WELL GRADED SANDY GRAVEL GW 2:15 2:15 2:15 2:15 2:15 6 0 16 0 0 16 / 6 0 16 6 0 16 0 0 16 / 6 0 16 6 0 16 0 0 16 / 6 0 16 6 0 16 0 0 16 / 6 0 16 6 0 16 0 0 16 / 6 0 16 6 0 16 SEE SITE PLAN Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201009, Rebecca Carroll, 01/30/20 MUNICIPALITY OF ANCHORAGE '& ~ ' · DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Health Division ~ 825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Name DISTANCES Address ~- ~a ~ SEPTIC ADSORPTION Phone(s) Pe~mil NO. No.o rooms WELL ~ ~ ~ O~l ~d LOT LINE LEGAL DESCRIPTION Township, Range, Sec[ion I ~ J ~ ~ I ~ ~ dPveway,AS-BUILTwaterDIAGRAMbodies, etc)(Sh°w location of well, septic system, prope.y lines, founda,io.. m~.~s IN ~ SEPTIC D HOLDING Manulacturer Capacity ia gallons M~terial u NO. of CompaRmen s TYPE OF SYSTEM (~ ~TRENCH ~ BED ~ W. DRAI. ~OTHE. oggin~lOepth to ~ipe bmtom 'mmgrade FT Total depth from odgina, grade FI Gravel length Gravel width - FT FT ~,~ c ~"'~ /1'/,// I I Total absorptio~ area Distance between lines ~ ~ ~.~/ !,'/I // / SQ FT FT / . ~5 / //~ ~ PRIVATE ~ OTHER (Identify} ~ ~ ~0~ / Classification (A,B,C) Total Depth F~ Cased to Installer Date Installed: REMARKS: MunicipalandStateDuidelinesJnellectonlhisdat~ ~J~J~ / / 72-013 (3/85) Depaptm~:r'~t. c)f Health & Human Sepv:Lces ,825 I.. St.r'e)~'L, Anc:hc~r'age!~, A].a!~,ka 99501 J;4J:.....~) D N -. S I T E f3 E P T i C T A N K F:' E R I*1 ]; T :, ~ Upg p acl~ F?.O B [ii:F;lT J. 6730 CF:d:)I::)KE):) TF?.Fi:E A N E;H'E)I::~ A[!}ti!:, AK 995 Day 549"'4A08 Block: SEPTIC 'rANI<: Minimum t, crLa], s{~pt, ic i',anl.:: 'k.~;u"~k mt,ust ho. ye at ].,.'<,o.~_~t. 2. cc)mpa, r.t. merU_'.s,, feet. p~)quipe!s: iri~iL~].~d:.:i, on OVi~SH" 'i:.ar'iJ,:: (s)., c:apac:i.t.¥: 1.,250 ga:l. lc)ns. Each ~sept. ic: D~p'Lh 'Lis top Df ss~pt, ic ]:NS'T'AI..,L. PE!:;~ I~:N[.~INIEEF~S DESI6N. TH]i~3 F:'IEF.'.M ]: ]" EXPIREB 12 /:5 :!. /87 AND :1: S i SSU!i!:i) FI)t::;.' THE E X I S']" I NE-; 4 BEDI.:;tOEIN S I Nt3LE FAM I L_Y DNIEL.[.. I N[~) ONL. Y S i gnc, d: ((3wnep) CEIRTIFY THAT:i :l.,. Zi: am fam:i, liap ~-~:Ltlq t.l'%'.:, pequ:i.l, em~nt~ f(:m cln.-~ii'L~ set~Je)l-s arid we~].].s a~, set, fopt. l'i by '1:i~6~ I~tunic:i.l:}a].i'Ly of Anc:l-lclpag~ (MOA) and t. he State cif A:l. asl.::a. ): will ins!fLail 'l'.,l"lce syst.~,~m in ac:cc~pdanc:e with a:l. 1 MOA c;clc:!6o~ and pegulat.;i, cirls~ arid iH c:C, ml)].J.o, nc:e wit, h the d~s:i, gn crit. epia of t:hi~ pe~,rmi'L,, I ~:i. ll adhepe t.o a].l MOA and St.~,c~e of A1asl<a r'equi~-ements {(:m t.he set back distances fl-c:mi any e>:isting wce].l, w~ast, e~,~at.e~r' di~q:c)sa] system of public: se~wi,(,p,s:~ge~ ~sys;t.e~m or'l t. hif~; ~;:)1' al"!y ad.jac:en'i:, or nc~apby I uridep~st, and t.l"la'L '!:.his per'mit, J.s valid for al/ maximtim of 4. also und~r'st, ar~d t,l'lat, t. hc~ Cal::iac:it.y of t, het. otal sy~illt, a,m :i.z~ 4. Izl~dpc:ic)nis arid arty e~r'ilar'gern~,n'L ~t~i].J_ Pe)qLt:i,i"ce an addit,;LCllia.], I::i'.i3BEi::iT J,, i::iEIOD MOUNTAIN ENGINEERING 10251 ORESTVI~::W EAST EAGLE RIVER, ALASKA 92577 [907] 696-1700 [800] 478-0101 MOUNTAIN ENGINEERING (~RESTVI~W EAST EAGLE RIVER, ALASKA 89577 [SOO} 478-0101 GRE, , ER ANCHORAGE AREA BOII',%IGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME ~}g-~.-- ~'- ~-~-~,/-¢,.-¢/,~ MAILING ADDRESS LOCATION ~D~ ~&--Z> SEPTIC TANK: DISTANCE ~/ FROM W/~.~ ~[O1¢' MANUFACTURER LEGAL DESCRIPTION PHONE gL MATERIAL NUMBER OF COMPARTMENTS' INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH __ _LIQUID CAPACITY / 2- ~~O GALLONS. SEEPAGE PIT: NUMBER OF PITS LINING MATERIAL BUILDING FOUNDATION ~;~ ADDITIONAL ABSORPTION [ DIAMETER __. OR WIDTH CRIB SIZE: DIAMETER NEAREST LOT LINE ~O /¢'- LENGTH DEPTH ~--~/~ a' DEPTH //,~/DISTANCE FROM: WELL TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA),~t:~-~;~/4,~;~-~? SQ. FT. WELL: ~'g,~-~-~ ~. TYPE BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION ~I~9~)d~D NEAREST NEAREST LOT LINE SEWER LINE OTHER SOURCES DISAPPROVED REMARKS DEPTH SEPTIC ~_~ H- TANK '"" ~¢" , DISTANCE FROM: SEEPAGE /¢., SYSTEM ,~ 0 DISTANCES: INSTALLED BY: ~'~-Z ~' PIPE MATERIAL: LOT SLOPE: REMARKS: DIAGRAM OF SYSTEM DATE ~¢./-27./~$ APPROVeD/z"] .... ~ ~'. ~: G.A.A,B. NO. LQ-D31 GREATER ANCHORAGE AREA BorOUGH PERMIT NO, DEPARTMENT OF ENVIRONMENTAL QUALITY SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT INSTALLATION OF: SEPTIC TANK ~ SEEPAGE PIT ~ ~ , DRAIN FIELD ., OTHER TYPE A{4D SIZE OF FACILITY TO BE SERVEEi ~7/~~~ ~ ~' FINANCED THROUGH TO BE INSTALLED BY comPletiOn DATE ANTICIPATEd /~ ~ ~ ~~ ' WELL TO SEPTIC TANK ,//~ ' DRAIN FIELD //~-~ ! WATER MAIN TO SEPTIC TANK .~) / DRAIN FIELD 10 ~ SEPTIC TANK, _/UU/ SEEPAGE PIT /~ ' TO RIVER, LAKE· STREA~. · SEEPAGE PIT ?/-~0 ~ , ALSO CONSIDER AREA WELLS. DRAIN FIELD CAST IRON INTO AND OUT Of SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURE~ED SOIL, 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTight REMOVABLE CAPS. CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. I CERTIFY THAT [ AM FAMILIAR WITH THE REQI DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. FORM NO. EO-016 ORDINANCE NO. 28-68 AND THAT THE ABOVE TEST HOLE NO. I 'DATE,., 8-7.1-73 PROJECT Te,st Hole For Seepage . W.O. Pit EL~. TOP OF HOLE CLI~T Earl Clabo ~.~ ' 'Li~ght B~ow~_..$i I,ty.and.~QBd ~nd..GFa~.l yLi~h Sm __ .Occasior~al Roc.k 6" Est., ..[/2 _&.i_l ±..I/2, Grav. e£ -- ' GM. ±o .SH. 243.25.. ' -....~ ......... __ Loose Sa~.d _~J~d OrTavel .... ·. ..................... ' .Gravel.l.y_.Sand. Yery. Ll±t e S ± -- (Damp) N.,F,S, ........................ '- ~ Occasional Cobb les.8'!- Maximum ..... GW 85 ................ Bottom of Ho I e ~/' -- ' Bottom' of 'HoIo.I~2 I/2'..''i "".'", '.]-'.].'.]']'5 ~ No Free Water Observed .... '.' .......... 1 1 f~L[..Bock (Pea Grave L- ".. .3 ...................... =-:-~ ............. 3 5 5 .... 8 8 -.-' 'lO ...................... lO ll ........... ll 12 ~ 12 13 ~ 13 14 ~ 14 .. _ ....... ' '" ~6 ................... ~6 .'. -~7 - '- ' .......... 17 18 .................................. -. ~ Z8 .19 -~ 19 20 ..................... 20 21 ~ 21 22 .............. 22 23- · .................... 23 ' 24 ........ 24 Municipality of Anctterage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON.SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-123-19 1. GENERAL INFORMATION Complete legal description Valli Vue Estates No. 2, Block 6, Lot 33 COSA # Expiration Date: _/"~ - ',,,~ -'//~.. Location (site address) 36730 Crooked Tree Circle Anchorage, AK 99516 Current Property owner(s) Robert J. Rood Mailing address 2440 E. Tudor Road Anchorage, AK 99507 Day phone 619-417-3614 Lending agency Mailing address Rea Estate~A. gent Mailing Add(ess Unless.otherwise requested, CQSA will be held by DSD for pickup. NUMBER ': OF BEDROOMS: Four (4) Day phone Day phone TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well [] Individual On-site [] Individual Water Storage [] Individual Holding Tank [] Community Class A Well [] Community On-site [] Public Water System [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DSD SIGNATURE ~ Approved for J~ Disapproved. Conditional approval for bedrooms. Date 5/27/2011 bedrooms, with the following stipulations: By: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: (Rev. 11/05) Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: Lot 33, Block 6, Valli Vue Estates No. 2 Parcel ID: 015-123-19 A. WELL DATA Well type Class A IfA, B, orC provide PWSID #210605 Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to ft. FROM WELL LOG Casing height (above ground) AT INSPECTION in. Date of test Static water level ft. ft. Well production WATER SAMPLE RESULTS: g.p.m. g.p.m. Coliform colonies/100 mL Nitrate mg/L Other bacteria __ colonies/100 mL Arsenic: mg/I Date of sample: __ Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,250 gal. Foundation cleanout (Y/N) Y Date of pumping 5/4/11 Date installed 919/89 Number of Compartments Two Cleanouts (Y/N) Depression over tank (Y/N) N High water alarm (Y/N) Pumper Denali Pumping and Water workS,',LLC Y N C. ABSORPTION FIELD DATA Date installed 9/27/73 Soil rating (g.p.d./~ or ~/bdrm) 85 SF/BDRM Length 12. ft. Width 12- ft. Total depth 11.5 ft. Eft. absorptiOn area >340 ~ Monitoring tube Date of adequacy test .~ I~"/.~ I.,'/,,~tt Results (Pass/Fail) Pass ~ I Fluid depth in absorption field before test I ~.~ in. Water added.~=.~ gal. Elapsed Time: !?)~_ min. Final fluid depth ~),~' in. Any rejuvenation treatment (past 12 mo.) (Y/N & type) ~ System type Absorption. Pit Gravel below pipe 6+ Y Depression over field N For 4 bedrooms NeW depth ~,~,~' Abs0rpt0n rate >= 6o0 If yes, give date in. g.p.d. LIFT STATION ~J/li~(' Date installed Size in gallons "Pump on" level at ~ in. "Pump off" level at ~ in. Datum Cycles tested E. SEPARATION DISTANCES Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank Manure/animal excrete storage areas Absorption field >5' Surface water >100' SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic service line Animal containment areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main N/A Water service line >10' Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10' Building foundation >10' Water Service line >10' Surface water >100' Curtain drain None Noted Wells on adjacent lots >200' Water main >10' Driveway, parking/vehicle storage >25' in. F. COMMENTS: Exact dimensions of absorption pit are unknown. Information from Municipal files does not specify exact measurements. Absorption pit size is adequate for four bedroom home. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 11/02/2010 COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number UNDER NO CIRCUMSTANCES SH~LO AN AS-BUILT ~E USED F~ C~S~UC~ ~ F~ ESTABU~ING BOUNDARY OR FEN~ UNES. THE SUR~YOR TAKES RESPONSIBIUTY FOR THE INI3AL ~ANSAC~ON ~LY AND ASSUMES ~N~AL UABIUTY ONLY F~ ~E COST ~ ~E SUR~Y, LIS~D DISTAN~S PREVAIL O~R SCALING. REPR~UC~ MAY CAU~ ~R~S IN SCA~. LO~ ~ SURVEY TYPE ~ SYMBOLS "~ F~NDA~ AS~BUILT ~ F,NAL S~UC~RE AS-~iLTJ o SET REBAR ~ ~ DRAINAGE ~ ASPHALT ~ PLOT ~ . . . AS-BUILT . . LOT ~R~Y . . T~HY ~ O F~ND REBAR ~ ~NCE ~ C~CRE~ ~ AS-BUILT . . . NO C~S ~T ~ ~CA~ ASn~I.LT NO C~N~S ~T ~ ASSUMED E~V. X X X METAL ~NCE ~ ~OD DECK PLOT PLANS ~ LOT SUR~YS NOTE: IT IS ~E RESPONSIBILITY OF THE BUILDER OR O~E~. PRIOR TO ONLY THOSE IMPRO~MENTS ABO~ ~OUND AND ~Si~LE ~LL BE CONS~UCTION, TO ~RIFY PROPOSED BUILDING GRADE RELATIVE SHO~. FENDS. ~S, SEP~C C~AN~TS, SIDEWALKS, DRI~WAYS, TO FINISHEO O~AOE AND UT[LI~ CONNEC~ONS AND TO DE~RMINE ETC.. ARE SHO~ IN ~EIR APPROXIMA~ LOCA~ON, ONLY. SNOW THE EXIS~NCE OF ANY EASEMENTS, CO~NANTS OR RES~IC~ONS MAY PRE~NT SOME IMPRO~MEN~ FROM BEING SEEN ~0 L~A~D. ~t..~H D.0' NOT A~pEAR ON THE RECORDED SUBDIVISION PLAT. AL~....DISTANCES A~E RECO~D UNLESS OTHE~[ NORD. SURLY CERT~nCA~ON T .......... Prepared by Robert E. Johns, Jr. Assoc. RNAL S~UC~RE AS-BUILT -- ," o~ Legel De~ri~ti~: ~ ..... ~ ..... .~,-~ Lot 33 Block 6