Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
SEPTIC TANK:
DISTANCE /~D/ - " C COMPARTMENTS
FROM WELL MANUFACTURER _ . ~MATERIAL ~
!
INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH_ LIQUID CAPACITY/ ,GALLONS.
SEEPAGE PIT:
NUMBER OF PITS ~ DIAMETER
Co~4 r/",p~cR,B s,zE:
L N NG MATERIAL
BUILDING FOUNDATION NEAREST LOT LINE
OR W,DTH/O: LENGTHP,' DEPT.
DIAMETER DEPTH DISTANCE FROM: WELL /~<~ ~
TOTAL EFFECTIVE
ABSORPTION AREA (WALL AREA) /~ ~ SQ. FT,
ADDITIONAL ABSORPTION
WELL:
BUILDING
FOUNDATION --
CESSPOOL
APPROVED
CONSTRUCTION
NEAREST
LOT LINE
OTHER SOURCES
DISAPPROVED
,.-P &'/~/'~/4 DEPTH /"/ / DISTANCE FROM:
NEAREST SEPTIC SEEPAGE
SEWER LINE TANK SYSTEM
REMARKS
DISTANCES~
INSTALLED BY: I~/~2" 4]k ~-
PI PE MATERIAL:
LOT SLOPE:
REMARKS: ~ '~" ~
Form No. EO-031
DIAGRAM OF SYSTEM
I! / ~
GrEATEr ANCHORAge AREA BOROUGH
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
PERMIT NO.
INSTALLATION LOCATION
PHONE
INSTALLATION OF: SEPTIC TANK ~/ SEEPAGE P~T / ., DRAIN FIELD
FINANCED THROUGH TO BE INSTALLED ~Y ~
j OTHER
WITHOUT BOIL TEST
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
FOUNDAT[ON TO SEEPAGE P]T ~ /
SEPTIC tank _, seepage pITC~/]
TYPE~
SEEPAGE AREA SIZE
DRAIN FIELD
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK
WATER MAIN TO SEPTIC TANK
DRAIN FIELD
TO RIVER, LAKE, STREAM.
DRAIN FIELD
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRiB CROSSING GAP OF
EXCAVATION 5 FEET iNTO UNDISTURBED SOIL.
4 INCH/DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PiT
F~TTEDWITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACKFILL
CONFO}:{M Ti ~OR ~L~;ii~
TYPE
DIAGRAM OF SYBTEM
I CERTIFY THAT ] AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORA(~;E AREA BOROUSH ORDINANCE NO. 28-68 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SA~D CODE.
% - Department of Environmental
'~ 3330 "C" Street
Anchorage, A1 as ka 99503
¥
~ . / SOILS LOG - PEROLATION TEST
Performed for ~L ~ ~ w& ~ /~r Da
.... · · . ~ ~ ~ ~ ~e ~erto~eo
Lega~ Description: ~ ~/Z ~'~ z~ ~z,,. "~
TMs form reports: Soils log, ' ~ / Pe~iOn test -'
Depth
Feet
4-
5-
6-
7-
8-
9-
lO-
ll -
Was ground water encountered? ~.. If yes, at what depth? II-/~ .
Reading
Date
Gross Time
Net Time
Depth to Water
Net Drop
Po r c o 1 a t i b-n-' 'r-a t--~ ............ ini~-.
· Proposed installat-T6-nT Seepage Pit Drain Field
)eoLh of Inlet . Deptll--t-o'-b-o~tb~-o-f--pit o? Lrench ......................
coh~..,~.Ts- n~WT~-~Y.-T2~>_z~ ~ ~ '~~ ..................
.- ...... e- ............. ....... ?/Z. .........
EQ-040 (6/74)/
GREATER ANCHORAGE AREA BOROU:
Department of Environmental Q~.~ity
3330 "C" Street
Anchorage, Alaska 99503
SOILS LOG - PEROLATION TEST
Performed for ,~__~ll~._~- CO~,~C~--~--F~ Date Performed_~
Legal Descrip~~]~ ~UT$~dIS/O~) -- __
This form reports: Soils log xF~5 Percolation test
Depth
Feet
3 - ,,JOE) ~,~./.~.~ .
6 C/h'eTps og
l~as
g~ouh~o- water encountered?
__/~0~ ~r~ If yes, at wi~at depth?
Reading Date
Gross Time Net Time Depth to Water Net Drop
Percolation rate minute.
· Proposed instailat-T6-n-: Seepage Pit Drain Field
8epth of Inlet . Depth to bottom of pit or tre.nch
PER CENT FINER 8Y WEIOHT
MUNICIPALITY OF ANCHORAGE
' DMSION OF ENVIRONMENTAL HEALTH
DEPARTMENT OF HEAL~UH AND ENVIRONMENTAL PI~OTEC-r~ON
· APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Informati.,on_ Application Date June 26, 1984
(a) Legal E~sc~iptic~ (include lot, block, subdivision~ section, t~nship, ~arg$)
Lo%s
11 & 12, Block 8, Pipple Subdivision
Location (addz~ss o~ directions)
~n'~n~'~ nf T,,qny ~q]~16~ Riv~': AK
(b)
Applicants Nams~ Robert Hartzler
~ Box 9389 Eagle River,
Applicants Add~ess
(c) Applicant is (chsck one) Lending Institution
Buyel~ ~; Othsl~ ~ (explain); __
(d) ~nding Institution N/A
AK
Te lephor~ 694-9821
99577
~; Owner/builder ~;
Te lephose ~
Address --
(e) Neal Estate Co. & Accent ERA Star,....~_~ril Lee
Add~ess
Telephose _ 561-1333
2. ~fpe of ~siden___~_~
Single-Family ~
Numbe~ of Bsdrooms
3. Wate__~ Supply_
Individual Well ~
Multi-Family
Othe~ (describe)
Public
Note: If cc~munity w~ll system, must have written confirmation f~n the State
Department of E~lvirol%msntal Conservation attestinG to th~ legality and status.
Is the ~11 adsquabe fo= th~ number of bedrooms specified in this HAA (Y/N) Yes
Se wage Disposal
Onsite ~ Public ~ C~m~Unity ~-~ Holding Tank ~
Is the wastewate~ disposal system adequate fc~ the numbe~ of bedrooms (Y.~/N) Yes
{Page 1 of 2]
2-15-84
51 ~irm Provi. di.n.~ Inspections ! .Tes~ts, .Data and Information
I ~rtify that I havo ch~cked, verified, o~ oonforn~d to all ~OA HAA Guid~l
S igr~d /~L~.~_ / /~_~ // Date /~/~/~
/
Nares of Fizla n ben ineers, Inc. Telephone 694-5574
Address l__~eDoux E~_~_~e_ River
Si9~ed by V__~ernon L. Roelfs ~
Date June_ 26_~z_ 1984
(ENGINEER SEAL)
Approved for
Appro~d ~
AK 99577
DisapFa?ov~d ~ Conditional ~--~
Temr~ of Conditional Ap~oval ·
The Municipality of Anchorage Dapa~tment of Health and Environmental P~otection does
not ~aara~tee th~ c~%tinued satisfactory ~fo~mance of the water supply and/c~ the
wastswato~ disposal system° This approval indicates that, as of the validation date
sho~n ahoy, based o~ th~ data and info~.mation furnished by an engineer registe~d in
the State of Alaska, th~ %~ater supply and wastewater disposal system is safe and func-
tional fol~ the t~unbe~ of be. droons and'type of structure indicated.
( DHEP SEAL)
7. Mail the HAA to the following address:
Call April Lee at 561-1333 for pick-up
KB2/d5/s
{Page 2 of 2]
2- ~. -84
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (MAA)
,MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH 8,
ENVIRONMENTAL PROTECTION'
FEBRUARY 1984
· -Legal Description: ~YE D ~CH~CKLIST
WELL DATA ~ q Lots 11 & 123 Blk 8~ Pimple Subdivision
-
~.., B, O~ C, D.E.C. Approved(Y/N) N/A
Well Classification
Well Log P~esent (Y/N) No
Total Depth 171 ' Cased to
Static Water Level 45'
Casing H~igh~t Above Ground ' 24"
Electrical Wiring in Conduit (Y/N) Yes
Separation Distances f~cm Well:
To Septic/~qolding Tank on Lot 100'+
To Nearest Edge of Absorption Field on Lot
To Nearest Public Sewer Line N/A
Date Completed
Unknown
Pump Set At
Unknown Yield O,5 ~om
Depth of Grouting Unknown
UnknDwn
Sanita~ySeal on Casing (Y/N)Yes
Dep~essionA~oundWellhead (Y/N)No
; On Adjoining Lots 100'+
100'+ ; On Adjoining Lots 100'+
To Nearest Public Sewer
C~anout/Manhole N/A
Water Sample Collected By Mike Ha~an ; Date 4-25-84
Water Sample Test Results 0/100 ml; Negative
Cu,~nts Well log could not be found. Some information
inspec$ion report.
To Nearest Sewer Service Line on LOt, 25'+
B. SEPTIC/HOLDING TANK DATA
Date Installed 7-24- 75 Size 1250 No. of Ccmpa~tments 1
Standpipes (Y/N) Yes Ai~-tight Caps (Y/N)Yes Foundation Cleanout (Y/N) No
Depression ove~ Tank (Y/N) No Date Last Pumped 4-25-84
Pumping/Maintenance Contract on File (Y/N)N/A ; for N/A
Holding Tank High-Water Alarm (Y/N) N/A Temporary Holding Tank Permit (Y/N) N/A
Separation Distances f~om Septic/Holding Tank:
To .Water-Supply Well 10O ' +
To Property Line 30'
To .Water Main/Service Line 15 ' +
Course N/A
To Building Foundation 1 O0 ~
To Disposal Field 17'
TO Stream, Pond, Lake, o~ Majo~ D~ainage
Comments
[Page 1 of 2] 2-15-84
C. ABSORPTION FIELD DATA
Soils ~ating in Absorption Strata 250 sq ft/bdrmType of System Design Crib
Date Installed 7-24-75 Length of Field 80'
Width of Field 10' Depth of Field 6'
Gravel Bed Thickness 6'
Square Feet of Absorption A~ea 1080 sq ft Stan¢~piD~s r~esent (Y/N) Yes
Depression over Field (Y/N) No Date of last Ad~aa~f Test 4-25-84
Results of Last Adequacy Test Ad~qua%a
Separation Distanoe from Absorption Field:
To Water-Supply Wall 100'+ To Property Line 30'
To Building Foundation 100',- To Existing or Abandened System c~
Lot None located ; On Adjoining Lots 30'+
To Water Main/Service Line 25'+ To Cutbank(if present) N/A
To Stream/Pond/Lake/c~ Major Drainage Course N/A
To D~iveway, Parking Area, or Vehicle Storage Area 10' +
Conm~nts
D. LIFT STATION
Date Installed 7-24-75
Size in Gallons 25 g~llons
"Pump On" Level at U/~known
High Water Alarm Level at None
Din~nsicns 2' high X 1.5' diameter
Manhole/Access (Y~)
"Pump Off" Level at_A~L12/LX,
'volume
Vent (Y~])
Tested for 5 Pumping Cycles during Adeguacf Test. Meets MOA
Electrical Codes(Y/N) Yes
Coma~ents "Can" lift station is located in a 42" conc. manhole 11.5' below
the surface. Manhole fills with groundwater and wet well "e~m" is
always submerged. "Can" is watertight.
**
~ Check Permitted Bedroom Rating Against 'HA~ ~quest
I certify that I have checked~ verified~ o~ conforwed to all MO~ ~igA Guidelin~s in effect
on the date of this inspection.
Company ]~nteeh
KB1/d5/s
[Page 2 of 2]
Date ~.F~/ _
MOA No. ST84-018
-~ r, OF
L ~,. ~- ~' ..... ~ ~ ~ ~
2-15-84
TECH ENGINEERS INC.
CIVIL "SANITARY
June 26,
Municipality of Anchorage
Department of Health & Environmental
Protection
825 "L" Street
Anchorage, AK 99501
1984
~UNICIPALiTY OF ANCHOP. AG~
DEPT. OF H~ALT~i &
E,~WRO~,~N~-^~ ~O~cnoN
.RECEIVED
Re: Robert Hartzler, Health Authority Approval (HAA)
Application; Lots 11 & 12, Blk 8,
Pipple Subdivision
Dear Sir,
During the period from April 25 to June 26, 1984, we
performed research, investigations and testing pursuant to
Health Authority Approval on the above referenced lot.
We performed a flow tes~--en-~t~w~e~l~l~--~nd found the
output to be adequate fo~4 bedroom house~ (Refer to
Water Yield Test, attached~.-~--W~'~lso--too~a wat~sample~
for bacteriological analysis and results wer~nega~iv~_e
(Refer to Chemical & Geological Laboratory ~A~a~yt~cal
Report, attached).
We also performed an adequacy test/~n~th~septic system
and found that it absorbed at a rate o~ 688~11ons per day
(gpd). This is more than the 600 gpd requi~ 'red for a 4
bedroom house and the system is therefore adequate. The
septic tank was pumped as part of the test and the volume
was verified to be~allons.
To our knowledge, we have assembled all available
information on the HAA Checklist and Application Form. We
offer this information for your review. Please call if
you have any questions.
Sincerely~
Vernon L.
cc Robert Hartzler
Attachments
HAA Application
HAA Checklist
Water Yield Test
Sewer As-Built
Chemical & Geological Testing Lab,
Total Coliform Analysis
13LEDOUXLANE · EAGLERIVER,ALASKA 99577 ' TELEPHONE
TELEPHOI~E (907} 562-2343 ANCHORAGE INDUSTRIAL CENTER
5633 B Street
.Drinking Water Analysis Report for Total Coliform Bacteria
TO .E oO~PL~D ~¢WATER suPP,l~
~ ~'~ ~'~ '~1, /J ~ '" See h on back
WATER SYSTEM: ~.o. NO.
Phone No.
Waler S~tem Name
City
Mo. Day year
Zip Code
SAMPLE TYPE:
Routine
I~' Check Sample (for routine sample
with lab ref. no ~
[] Special Purpose
[] Treated Water
[] Untreated Water
SAMPLE
NO. LOCATION
3 L
Time Collected
Collected By /
TO BE COMPLETED BY LABORATORY
Analysis shows this Water SAMPLE to be:
,~atisfactory
[] Unsatisfactory
[] Sample too long in transit; sample should
not be over 30 hours old at examination to
indicate reliable results. Please send new
sample via special delivery mail.
Date Received
Time Received
Analytical Method:
[] Fermentation Tube
El Membrane Filter
Lab Reft No; Result* Analyst
I
L I FT3
L J F~
READ INSTRUCTIONS
BEFORE
COLLECTING SAMPLE
06-1220
Rev. 1983
BACTERIOLOGICAL WATER ANAL¥515 RECORD
Membrane Filter. Direct Count Coilform/100ml
Verification: LTB__ BGB_
Final Membrane Filter Results _--~ Coilformll00ml
Reporled By._~ ~ Date --
Time: .... ~/'~'%'~)
TNTC = Too Numerous To Count