HomeMy WebLinkAboutLot 16 (2)
Department ~o~Cn~virco,~n~m~ental Quality '
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION
DISTANCE
FROM WELL tO~'''~1
INSIDE LENGTH
MANUFACTURER[) %TA(-I< ~"'~.- . MATERIAL
INSIDE WIDTH
LIQUID DEPTH
NUMBER OF
COMPARTMENTS
LIQUID CAPACITY I ~'00 GALLONS.
SEEPAGE PIT:
NUMBER OF PITS DIAMETER OR WIDTH
LINING MATERIAL __ CRIB ~PTH____ DISTANCE FROM: WELL ___
BUILDING FOUNDATION ~T~VE~A (WALL AREA) SQ. FT.
TYPE CONSTRUCTION DEPTH DISTANCE FROM:
BUILDING NEAREST NEAREST SEPTIC SEEPAGE
FOUNDATION LOT LINE SEWER LINE TANK __ SYSTEM
CESSPOOL. OTHER SOURCES
APPROVED DISAPPROVED REMARKS
DISTANCES:
DIAGRAM OF SYSTEM
INSTALLED BY:
PIPE MATERIAL; ~C~f
LOT SLOPE:
REMARKS:
Form No, ED-031
APPROVED//~/~ ~'~C
l/G.A.A.B.
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION
MAILING ADDRESS.)
LEGAL D E SC R I PT I OlXlXi<*~ ~/~
SEPTIC TANK:
DISTANCE
FROM WELL /',~2(? /
INSIDE LENGTH
- , . NUMBER OF
MANUFACTURER ~//2~;'/~ %~/~// MATERIAL X ~/~-'J//-/';///Y;'/ /;/,/~ COMPARTMENTS /
INSIDE WIDTH ' LIQUID DEPTH __
LIQUID CAPACITY ./(/~'~ GALLONS.
SEEPAGE PIT:
NUMBER OF PITS /' DIAMETER OR WIDTH/~]./ LENGTH/~/,/ DEPTH
LINING MATERIAL~///',:';'~'/> CRIB SIZE: DIAMETER DEPTH DISTANCE FROM: WELL /,,~2 ~'~ '
/~'22z~- .~ TOTAL EFFECTIVE
BUILDING FOUNDATION ~2/, NEAREST LOT LINE ,~'?'~ / ABSORPTION AREA (WALL AREA) _) ,~) ,- SQ. FT.
ADDITIONAL ABSORPTION
WELL:
'YP~ r~ ~' :~: CONSTRUCT'ON
DEPTH DISTANCE FROM:
BUILDING NEAREST NEAREST SEPTIC ~ ~ / SEEPAGE
FOUNDATION ./~x~/ LOT LINE -- SEWER LINE - TANK /_g''_,C' , SYSTEM
CESSPOOL ~-- OTHER SOURCES
APPROVED DISAPPROVED REMARKS
PIPE MATERIAL:
LOT SLOPE:
REMARKS: / ,_~2 ,"~ -
DIAGRAM OF SYSTEM
Form No. EQ-O31
GreaTeR ANCHORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" STREET ANCHORAGE, ALASKA 99503
SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT
PERMit NO.
NAME OF APPLICANT f~/~/
INSTALLATION LOCATION
PHONE
LEGAL DESCRIPTION
INSTALLATION OF: SEPTIC TANK
TYPE AND S]ZE OF FACILITY TO BE SERVED
FINANCED THROUgh
SEEPAge PIT ~ . DRAIN FIELD
SOil TEST RESULTS
OTHER
NOTE~ THIS PERMIT IS NOT VALID WITHOUT SOIL TEST
COMPLETION DATE ANTICIPATED
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
DIAGRAM OF SYSTEM
MINIMUM DISTANCEB, REQUIREMENTS
FOUNDATION TO SEPTIC TANK
FOUNDATION TO SEEPAGE Pit ~f
SEPTIC TANK TO SEEPAGE PIT WALL
, SEEPAGE PIT
SEPT]C TANK I~/
TO NEAREST LOT LINE.
WELL TO SEPTIC TANK ~/~'~
DRAIN field 1~
WATER main TO SEPTIC TANK
TO RIVER· LAKE, STREAM.
, DRAIN FIELD
DRAIN FIELD C~--~/
, SEEPAGE PIT //~'/
· ALSO CONS[DER AREA WELLS.
, seePage PIT //~
DRAIN FIELD
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSS]NG GAP OF
EXCAVATION 5 FEETINTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit
F[TTED WITH AIRTIGHT ~EMOVABLE CAPS.
GRAVEL BACKFILL
BO REGULATIONS REGARDING INSTALLATION.
CERTIFY THAT [ A~ FAM]LIA~{ WITH THE REQUIREMENTS OF GREATER ANCHOEAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE
GREATER ANCHORAGE AREA BOROUGH
DEPARTMENT OF ENVIRONMENTAL QUALITY
3330 "C" Street
ANCHORAGE, ALASKA 99503
Case #
Performed For /~a~ ~
Legal Description! Lot /~ Block
This Form Reports Soils Log
Soil Test Must Be Logged
Depth
Feet Soil Characteristics
2--
4--
5--
6--
7I,
9--
10--
11--
12--
13--
14--
Dated Performed
/~ _Subdivision~
Perddlation Test
To 4' Below Proposed Seepage System
Was Ground Water Encountered?
If Yes, At What Depth?
Reading Date Gross Time Net Time Depth to H20 Net Drop
Percolation Rate Minute
Proposed Installation: Seepage Pit
Depth of Inlet .Depth to
COMMENTS:
Bottom of
Drain Field
Pit Or Trench
Test Performed BY_/C/o~-~ ~ ~_ Date Certified BY:
Date:
C~"~ATER ANCHORAGE AREA BORO'~"~H
~/ HEALTH DEPARTMENT
327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511
N: 669
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION .,Gx~nl~ ,4f~z,~p z/~q,~ ,~.
SEPT,C TA Ki "
DISTANCE FROM WELL
UQU~D CAPAaTY /~rO
GALLONS.
MATERIAL ~z~~-I NUMBER OF Z
, COMPARTMENTS
LIQUID
INSIDE LENGTH INSIDE WIDTH DEP~H~
SEEPAGE SYSTEM: SEEPAGE PIT:
NUMBER OF PITS / OUTSIDE DIAMETER OR WIDTH /~'~/
HN~NG
J
NEAREST LOT LINE ~? ~7~ ~('~O~/,~ . TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA)
, LENGTH ,/~ , DEPTH
BUILDING FOUNDATION
~'~c~OO SQ. FT.
TILE DRAIN FIELD:
DISTANCE FROM WELL ~TION , NEAREST LOT LINE.
DISTANCE BETWEEN TRENCH WIDTH
NUMBER OF LINES LINES-
ABSORPTION~K~ SQ. El. LENGTH OF EACH
DEPIH: lOP OF TILE 10 FINISH GRADE
TOTAL LENGTH
., OF LINES
/~IN. TOTAL EFFECTIVE
DERIH OF EILIER MATERIAL BENEAIH TILE IN. ABOVE IILE
DISTANCE FROM
WELL:
TYPE ~1~//~=/~) DEPTH , BUILDING FOUNDATION.
SEEPAGE
NEAREST SEPTIC
LOT LINE '~ ~ SEWER LINE Jl/.aJt/,~' TANK /,~ . SYSTEM
WATER
SAMPLE /~D/~r , NEAREST
OTHER
, CESSPOO~ /~'D/ML~ , SOURCES ~
DISTANCES:
DIAGRAM OF SYSTEM
DATE
!!ii
GREATEi,._ ANCHORAGE AREA',...._:)ROUGH
HEALTH DEPARTMENT
327 Eagle St. Anchorage, Alaska 99501 279-2511
SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT
NAME OF APPLICANT/~ ~7/'/' z~, ~-
RESIDENCE ADDRESS ~vX
LEGAL DESCRIPTION
APPLICATION TO INSTALL: SEPTIC TANK
TO SERVE THE FOLLOWING FACILITY
FINANCED THROUGH .~'~
PERCOLATION TEST RESULTS
~ILINGADDRESS ~?/~ /d/,:~A PHONE NO.~z/?~
LOCATION OF INSTALLATION ~/~///J~' ~?z /~/~,
SEEPAGE PiT. ~ ,DRAIN FIELD .,OTHER.
ANTICIPATED DATE OF COMPLETION
BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT
THIS IS TO SERVE AS ~ / ~ , PERMIT TO INSTALL A --,~ ~,e.~ AS DESCRIBED BELOW. SIZE OF UNIT TO BE SERVED ~
· SEPTIC TANK SIZE /P~ TYPE ,~',~ ~ SEEPAGE AREA
DIAGRAM OF SYSTEM
DISTANCES:
Health ,~ority
I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the
above described system is in accordance with said code.
DATE APPLICANTS SIGNATURE
MEMORANDUM
DATE: ~
SUBJECT:
91-010(4/76)
CONSTRUCTION AND OPERATION CERTIFICATE
ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION
PUBLIC WATER SYSTEM
APPROVAL TO CONSTRUCT
Plans for the construction of
approved,
BY
Public water system located
, Alaska, submitted in accordance with 18 AAC 80.100
have been reviewed and are
4 " ;
DATE
[] conditionally approved (see attached conditions).
If construction has not started within two years of the approval date, this certificate is void and new
plans and specifications ~nust be submitted for review and approval before construction
APPROVED CHANGE ORDERS
Change (contract order no, Approved by Date
or de$Crl 3rive reference)
The "APPROVAL TO OPERATE" section must be completed before any water is made available to
the public.
· APPROVAL TO OPERATE
The construction of the public
water system was completed on (date]. The system is hereby
granted interim approval to operate for 90 days following the completion date,
eY TITLE DATE
As-built plans submitted during the interim approval period, or an inspection by the Department has
confirmed the system was constructed according to the approved plans. The system is hereby granted
final approval to operate.
EXCAVATION
WORK
ROBERT A. SHAFER
July 24,
CIVIL ENGINEER
694-2979
1983
J U L 2 7 1983
Mike Spangler "~!!~?": ' ;ag~"
P.O. Box 1007 "~'?i '] &
Eagle River, Alask'a 99577 En'/ii'~mi~l,.~, ~;',~cti0rl,,
Dear,..,.~"~'. Span~lez',
Reference: Lot 16A: Block 12; Walter G. Pipple Subdivision:
Addition ~2
A sewer system adequacy was performed'on the system located on
the referenced property, as you requested. The septic tank
and seepage pit had to be excavated and clean-outs placed in
each. After this was done the septic tank was pumped and the
tank was verified to have a~capacity of 1000 gallons. The
seepage pit was charged with 1000 gallons of fresh water and
after a period of 24 hours it was determined'that approximately
1168 gallons of water had percolated out of the crib.
It can be concluded from this test that the waste water disposal
system is currently functioning adequately' for its current use,
however, based upon your proposed construction of a 10,000 square
foot retail sales outlet building, it will be necessary for you
to have a 500 gallon septic tank~added to the existing tank.
.The seepage pit should provide adequately percolation for the
amount of water anticipated based upon the fixture units that
you have identified for this retail sales outlet.
The entire system, howeVer, has been in existance for many years
and cannot be guaranteed against subsequent failure.
If we may be of further service, please do not hesitate to contact
cc: [~unzczpalzty of _Anchorage
Department of Health and Environmental Protection
SRB 196X EAG'LE RIVER, ALASKA
Mr. Dee High
DOWL ~
4040 B Street
Anchorage, AK 99503 ~
Subject: Domestic Water Supply System, .Pogany Apartments, Eagle River.
Dear Mr. High: ~
The plans and specifications for the subject project are approved
for the features with which this Department is concerned.
Sincerely,
Kyle J. C erry, P.E.
Regional Environmental Supervisor
cc: AM-DHEP
sv
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Qualltv
3500 Tudor Road, Anchorage, Alaska 99507 279-8686
Date Received ~u~ust 21:1973
Time of Insoection 2:30
Date of Insoection~
R~QUEST FOR APPROVAL OF
INDIVIDUAl. SH~BR & WATER FACILITIES
FOR
CMRO
1. Aoprovsl Requested By: JOHN FELG~NHAUER
Address~524 ORD CO. FORT RICHARDSON 99505
2. Prooertv Owner: Marion Bowens
3. Lege] Description:,,, R2W., ~ec 2, Parcel
4. Location: Lampost Apartments
5. Type of Facility to be Inspected:L Apartments
Phone .- 86~2-6194
Phone, 694-9218 --
Walter G, PiDDle S bq~_ivision ·
B, Depth 73'
D. Bacterial Analysis Satisfactory
Number of 9edrooms: 14
6. Well Data:
A. Type Drilled
C. Construction
7. Sewage Dtsgosal System:
A. Installed
C. Septic Tank: 1. Size
D. Seepage Pit: l. Size
H. Disposal Field:
8. Distances:
A. ~ell To: Septic Tank 85'
· Nearest Lot Line
Foundation to Septic Tank
Absorption Area
Installer
1'500 Ga]s2. Manufacturer
2. Material Concrete
Total Length of Lines
, Absorption Area llO' , Sewer Lines
, Other Contamination
"~ Ab~orptlon Area
to Nearest Lot Line
Appro~a! Valid for One Year Prom Date $~gned
Grr;ater Anchorage Area ~orough, DeFartment of Environments] Quality
DIAGRAM OF SYSTEM
I certify that the information contained in this request for appreval to be a true
and accurate representation of the subject sewer and water facilities located at:
Signed Date