HomeMy WebLinkAboutWENTWORTH BLK 1 LT 10LoT
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
Pump Installation Log
Well Drilling Permit Number: _______________ Date of Issue: ____-____-____
Parcel Identification Number: ____-____-____
Legal Description Block Lot Property Owner Name & Address:
Pump Installation Date: _____-_____-_____
Pump Intake Depth Below Top of Well Casing: __________ feet
Pump Manufacturer’s Name: ___________________________ Pump
Model: _____________________________________
Pump Size: ____________hp
Pitless Adapter Burial Depth: _________ feet
Pitless Adapter Manufacturer’s Name: _________________________
Pitless Adapter Installer: ____________________________
Well Disinfected Upon Completion? XX Yes No
Method of Disinfection: _____________________________
Comments:
Pump Installer Name: __________________________________
Company: ___________________________________________
Mailing Address: ______________________________________
City: ___________________ State: __________Zip: _________
Attention: The pump installer shall provide a pump installation log to On-site within 30 days of pump installation.
· ...2.., ~... %~:.~,,.,' , MUNtC-IPALIT¥,OF ANCHORAGF
· . /~ ~ ~d'."~KE'PAP/FMENT-",.~? HEAF=T}~:AND ENV~RONMEN'T~A~ROTE'CTION
~ ~ i [-' d 279-2511 ext 224, 225 '
~/ .~.~q' b.7'~ Da~e Received: March 22. 1977
1st Inspection: Time I[~) ~- 2nd Inspection: Time
Date ~-~-77 Date
Inspector /Z ~D ~ ~l ~, Inspector
REQUEST FOR APPROVAL OF INDIVIDUAL
SEWER AND'WATER FACILITIES
Lending Institution Request: Alaska National Bank of the North ~/~ 6o~}oL~.
Mailing Address: Pouch 7-010 Phone': 278-4581 x 273
Property Owner:
Mailing Address;
3, Legal Description:
Charles/Shirley Hilliard Phone: 277-8879
% Ken Shaw, Dynamic Realty 279-7611
Lot 10 Block 1 Wentworth Subdivis'ion
Single Family Residence: (x) Number of Bedrooms:
Multiple Family Residence: ( ) Number of Bedrooms:
4
Well Data: Type Individual Depth Well Log Filed ( )
Construction Bacterial Analysis
Sewage Disposal System: On-site system ( ) Public Utility
Permit ~--~,~'--~,~- Installed Installer
Septic Tank Size Manufacturer
Absorption Area soils Rate Material
(x)
Distances: Well to Septic Tank
~o Sewer Lines Nearest Lot
Absorption Area to Nearest Lot Line
Line
to Absorption Area
Pa~,e Two ~ ~ ' '~'
~ ~. . ' Depar tmen~t'. of 'Bealt:h .and ,~nvironmenta 1. .. Pretec%ion
. ,,~, R~equest for Approvall of Individual 'Sewer and Water Facilities
Legal Description:
Lot 10 Block 1 Wentworth Subdivision
Comments:
Affadavit Attached: ( )
Letter Attached: ( )
Disapproved:
Date:
Department Worksheet:
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L Street, Anchorage, Alaska 99501
279-2511, ext. 224, 225
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
MUNICIPALITY OF
DEPT. O~ HEAt'DH
ENVIRONMENTAL
MAR .q
RECEIVED
1. Type of Inspection: VA FHA CONV. ¥,X
2. Property Owner: D'II,LIA?~g ~ CHAP,~F,S ~ & SNII'LgLY
Mailing Address: 3200 E. 40th
3. Name of Buyer: MILLER~ 1,{ICHAgL D. & SHARON L.
Mailing Address: 3488 Eide Street
4. Name of Lending Institution: Alaska National Bank
Mailing Address: Pouch 7-010
Name of Realtor or Agent:
Day Phone: 277-8879
KEN S HN,'!
DYNAMIC RFALTY
Day Phone: 279-1523 his
Phone:
XX 5.
Contact for entry
MailingAddress: 501 West Northern Lights Blvd. Phone:
278.-&581 ext 273
279--7611
6. Legal Description: Lot 10. Block 1, Wentworth Subdivision
Location: 3200 E, 40th Avenue,Anchora~e~ Alaska
7. Type of Facility to be Inspected:.
8. Water Supply
Type of Supply:
Single Family
Public Utility
If Individual, number of dwellings presently served
If Individual, depth of well.
Sewage Disposal System
Type of System: Public Utility
If Individual, date of installation_
nnie Oldw
Alaska National Bank
XX
No. Bdrms.__
Individual
Individual (on-site)
4
XX
72-O03(3/7G)
6RaATER ANCHORAGE AREA BOROUGH ~-
Department of Environments1 Quality
3500 Tudor Road, Anchorage, Alaska 9950'1 279-8686
Time of inspection ~.~ O0
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
2. Prooertv ~ner: ~ Phone,
5. Type of
Number of ~edrooms
A. Type
C. Const ructt on ~/~ D.
Depth
Bacterial Analysis
A. Installed _ 8. Installer
C. Septic Tank: 1. Size 2. Manufacturer
O. Seepage Pit: l. Size 2. Material ,.
7. Sewaqe Dtsoosal.System:
5. Dtsposa] Field: Total Length of Lfnes___
Distances:
A. ~el]. To:
Septic Tank ~ , Absorption Area , Sewer Lines
, Nearest Lot Line /~ ' , Other Contamination --
~oundatton to Septic Tank '> Ab~orption Area
C. Absorution Area to Nearest Lot Line ..... ·
~Requa~t for Approval of ~ ~lvidua] 5ewer & ~ater Paezlt~ze:e ,~
Page Two ~ ~
9. CommentS: ~~ ~
A~rova] Valid for One Year From Date Signed
Greater Anchorage~ Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTE~
I certify that the information contained in this request for approval to be a true
and accurate representation of the subiect sewer and water facilltles located at:
Signed Doge
'~BATER ,aNCHOP,~.GE /LRE^ BOROUC-~
iIEALI}i DEP.AR%~NT ~
$27 E^GLE STREET
ANCHORAGE, ALASKA 99501
279-2511
DATE RECEIVED
~}~ v<' INSPECT:
,;. ,..
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWAGE ~D WATER FACILITIES
FOR
1. Approval Requested By (',~/~/9/3
Address ,'~ ~ ~J~] ~- ~ ~ f~2
3. Legal Description. /~, 2~ ~3~' /
4. T~e of Facility to be Inspected~//~f~'~
Number of Bedrooms ~
Phone , .:/979 7_
5. Well Data:
B.
C.
D.
E.
Type
Depth :~'7z
Size
Construction
Bacterial Analysis
6. Sewage Disposal System:
Septic Tank (If homemade, show diagram on back)
2. Age
5. Nanufacturer
4. Installer
8
Approval Request £or Sew~ ~ Water Facilitfes
Page Two ~
$. Seepage Pit
2. Lin±ng
C...D£sposa] Field
i. Number of Lines
2. Total Length
7. Required ~easurements
A. ~ell to Septic Tank
B.. Well to Seepage Pit
C. Well to Sewer Line
D. Well to Property Line
E. Well to Other Possible Contamination
F. Foundation to Septic Tank
Foundation to Seepage Pit
H. Seepage Pit to Property Line
8. COMMENTS:
APPROVAL VALID FOR ONE YEAR FRO~.I DATE SIGNED.
GREATER ANCHORAGE AREA BOROUGH HEALTH DEPARTMENT
EDll70
, ~ . ~~ ~ ~ INDIVIDUA5 ..... SEWAGE AND ~ATER FACILITIES
a, Ba~i~ , .
,. ,.,..,..,
""--- 6. W~ data:
}c. Casin~ Size . ''
1. Sewe~ line
2. Septic tank
3. Seepage Area .... .~ /
~. Cesspool:
5. Property Line
7e
houses, barn, drainage ditch, etc.
Sew~g~ disposal system.
a. Age of system
b. Septic tank capacity in gallons. ,
Other sources of possible contamination, i.e., creeks, lakes,
....
c. Name of septic tank manufactumgr
1. If "home made" show diagram on reverse side of this form.
Disposal field or seepage pit size and type ~ ~_x2~~.
1, Distance ~o properCy-.Aine
to house foundation
Oct. 27, 1970
Alaska Stage Bank
P.O. Box 240
~chorage, Alaska 99S01
SUBJECT: Sewer ~nd i~a'i:er Systems for Lot 10,
Block 1, Wentworth Subdivision
Dear Sirs:
1his letter is to reconfirm that this Department
has granted approval for the s~n~er and water systems
for Lot 10, Bled{ 1, Wentworth Subdivision pending
the escrow of funds for hook-up to the B6rou,gh Sewer.
Sincero ly,
John R. LOe~ R.S.
Sanitarian
cc: C~tom Realty
~¢ a~ ~oor~ ~ Z.n~or~ bJ po.J~Zble ~ ~ 5p~ ot~ 1971.
DOT ,, ~,~ 1970
October 9, 1970
Veteran's Administration
Po O. Box 1599
Anchos&ge, Alaska 99501
SUBJECT= Scwes & Wares Systems fca Lot 10,
Block 19 Wen~osth Subdivision.
Dear
Ou~ Department's inspection o~ the sub,eat lot gas unable to reveal a g~eat
deal. Wa are not au~ whethes os not the~e ia a septic tank present os ~ust
how the sewes system As laid out. The well consttmation was psopes, however,
and a water sample p~oved to be satisfactory.
~s. Reasos of Custom Realty provided us with a lettasfro~ the Borough Public
Works conf~l~ ~ha~ ~he Bo~h sewe~ would be ava~l~le ~o the duplex this
fall poso~ly o~ a~ le~ by ne~ spr~nE. Since the 8ewe~ system seems to be
[une~ionin~ satisfactorily, approv~ of the p~sen~ system co~d be made by
~is Depa~ent pendin~ ~he es~ o~ ~ ~o~ h~k-up ~o the Bo~h
~s~em ~hen it baches avai~2e; the esc~ ~o be based on the ~s~
p~sented to ~ by Rober~ N. Hud~, J~., A~lhl~t=ative Assistant ffo~ the
De~en~ of ~l~c ~o~ks. Find a~tached a copy of his
John R. Lee,
Sanitarian
cc~ M~. heo Reasos
REPLY
Redif. prm ® 4S 471 SEND PARTS 1 AND 3 Wn'H CARBON INTACT - PART 3 WILL BE RETURNED WITH REPLY.
September 30, 1970
GREATER ANCHORAGE ArEA BOROUGh
2207 MoRAE ROAD
ANCHORAGE, ALASKA 99503
272--1577
OCT ~ 1970
DEPARTMENT OF PUBLIC WORKS
Leo C. Reasor
Custom Realty
7404 Nathan Lane
Anchorage, Alaska
Dear Mr. Reasor:
RE: SANITARY SEWER SERVICE - LOT 10, BLOCK 1, WENTWORTH SUBDIVISION
This is to confirm that the Greater Anchorage Area Borough Department
of Public Works presently has a sewer trunk line under construction
along E. 40th Avenue. This line could possibly be completed in the
Fall of 1970, but more probably will be completed in the Spring of
1971, and upon completion will service Lot 10, Block t of the Wentworth
Subdivision.
There will be a 2.6 cents per square foot assessment for trunk sewer
plus a lateral assessment. The rates for the lateral line assessments
for 1971 are not presently known, but we estimate them to be approx-
imately ten to eleven c~nts per square foot. There will also be
the normal service connection charge of between $200 and $250.
If you need further information concerning this matter, please feel
free to contact this office.
Yours truly,
GREATER ANCtIORAGE AREA BOROUGH
Robert H. Morriss, P. E.
Director of Public Works
rt b[. Huanall,