Loading...
HomeMy WebLinkAboutWYNTER PARK #1 BLK 2 LT 5 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP231327 Effective Date: Work Type: SepticTank Upgrade Expiration Date: Tax Code Number: 05149206000 Site Legal Address: WYNTER PARK #1 BLK 2 LT 5 G:1361 Site Mailing Address: 24418 PARK DR, Chugiak Owner: COOK CAROL LEE Lot Size in Sq Ft Design Engineer: NORTH RIM ENGINEERING Total Bedrooms: This permit is for the construction of: n,ernt Del)artmcnt 9/25/2023 9/24/2024 23435 ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: 15s�� —1-\,) Issued By: U'11 � Date: Date: Z S 20 2_3 3 MUNICIPALITY OF ANCHORAGE Development Services Department �) Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTICM/ELL PERMIT APPLICATION Parcel I.D. 05149206000 Property owner(s) COOK CAROL Mailing address 24418 PARK DR Site address same Day phone 688-4810 Legal description (Sub'd., Block & Lot) WYNTER PARK #1 BLK 2 LT 5 Legal,description (Township, Range & Section) Lot Size 23,435 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) 0 Septic Tank 0 Upgrade Q (w/wo AD U) Holding Tank ElRenewal ElDuplex (D) E] Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. ,,. (Signature of p r authorized agent) Permit/Rush Fees: Z 2 5 Waiver Fees: Date of Payment: J 2 S / 2-o'z-3 Date of Payment: Receipt Number: 650 Receipt Number: Permit No. 0 S P 2 31 _� 2 -+- Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc Municipality of .Mdiorage On-site Water and Wastewater REVIEWED FOR CODE COMPUAN OSP231327, Curtis Townsend, W �INEERING SteveEng.com WYNTBR PARK #1 B2 L5 - �� SPECIFICATIONS & DESIGN GUIDELINES Wastewater System Sizing: The current septic tank has failed- the seepage trench still functions. This lot is close to a half -acre and on public water. No adverse impacts are expected from tank replacement. Easements are depicted on the lot. The slope is indicated in the area of the septic system. No conflicts to neighbor properties. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. ® New 2- compartment, 1000 gallon septic tank. Watertight couplings on inlet & outlet. ® 5' minimum between the tank and trench. 5' to property lines & 10' to house. ® 4' of cover or insulation is required for tank; an equivalent of 1 " insulation for F foot soil cover. Tank & solid pipe must be set on well compacted, stable soil. • No large rocks for tank bedding. Plastic/fiberglass tanks require special bedding per MOA- sand or pea gravel. ® 4" diameter cleanouts with airtight caps are required 1 ' to 4' from foundation wall, prior to any 90 degree bend in 4 inch line, in 2nd tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. Manhole Riser required in I" tank compartment. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. ® Insulation must be placedover any pipe installed under driveways or parking areas. ® Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, ® Sewer Service Line is minimum 2% slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene (Dow Styrofoam HI/equal) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231327, Curtis Townsend, 09/25/23 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP231327, Curtis Townsend, 09/25/23 Lot 4 PARK DRIVE __--- O co !300.00 ;64.87 R M 30' Drainage N89059'41 "E 60.95 Test Lot 5 O a o O O Septic vent Storage y r y •f • hea c� deck CO cV 1 S .0 /y �' I -r. --22.1--, ._.._.35. S Ouse �e de 2 0 M' N r Wire fence co Shed co Easement M 20 N89059'41 "E 110.00 Tract 9 W r Lot 6 O O 0 O O U) 8507U NOTE: This property is served by a community well. Utility Easement This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product. �'► O� '' •. ,`�• . • • .. �,q , AS -BUILT NO CORNERS SET THIS DATE I hereby certify that I have performed a Mortgagees inspection in accordance with ASPLS Standards of the following �Q'• • • .SOVF or C/j described property: LOT 5, BLOCK 2, WYNTER PARK SUBDIVISION No. 1 .-� . 49th Anchorage Recording Precinct, Alaska, and that the improvements situated thereon are within the property lines ,, . * *# • • • �' • • • • 00 • • • • • • • and do not overlap or encroach on the property lying that improvements the lying • . ar '0� Izabeth L. Walatka . o/ adjacent thereto no on property J � p p p Y Y g 0 c� �, adjacent thereto encroach on the premises in question and ��� • • 8036 - LS • 44 -AM that there are no roadways, transmission lines or other = SCALE' ��— 40� ` �� • • • •� .AW 1 A;?,OFESSIos visible easements on said property except as indicated -hereon. Dated at Anchorage, Alaska \�►� this 14th day of September , 2023. EASEMENTS OF RECORD OTHER THAN ' ��' '�� FRED WALATKA & ASSOCIATES, L.L.C. THOSE SHOWN ON THE RECORDED PLAT ARE NOT SHOWN HEREON BE Engineers and Surveyors UNLESS OTHERWISE NOTED. FB 23-3, pg 14-15 907-248-1666 This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product. GREi' ANCHORAGE AREA BOP"'" H Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM SEPTIC TANK: D,STANCE FROM WELL '~ MANUFACTURER MATERIAL INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH __ NUMBER OF COMPARTMENTS .LIQUID CAPACITY /~ GALLONS. SEEPAGE PIT: NUMBER OF PITS / BUILDING FOUNDATION ADDITIONAL ABSORPTION DIAMETER ~ OR WIDTH ////," LENGTH/~//, DEPTH (.pi CRIB SIZE: DIAMETER ¢¢ DEPTH ~ / DISTANCE FROM: WELL TOTAL EFFECTIVE NEAREST LOT LINE ABSORPTION AREA (WALL AREA) SQ. FT. WELL: BUILDING FOUNDATION __ CESSPOOL APPROVED CONSTRUCTION DEPTH DISTANCE FROM: NEAREST NEAREST SEPTIC SEEPAGE LOT LINE SEWER LINE TANK SYSTEM OTHER SOURCES DISAPPROVED . REMARKS DISTANCES: IN,STA~LED BY: PI P~./. ATE RIAjL: LOT SLOPE: REMARKS: Form No. eQ-O31 DIAGRAM OF SYSTEM .//G.A,A.B. MgMICIPALIT¥ OF /~NCHORACE DIVISIOM OF E~IRO~ENTAL ~LTH DEPARTMENT OF I~TH AND ENVIRO~AL PROTECTION ~ppLICATION FOR ~TH A~HORITY ~PROVA~ CERTIFICATE G~.~,,.r~d ~foJmatioa Application Date .... ~ ...... ,.~' g~ er~.tion, (include lot, block, subdivision, section, to~ship,~ range) Location (address or directions) e (c) Applica_nt__is (check one) Lending Institution Euyer [ [ ; Other ~ (explain); (d) Lending Institution ~/f-?~__7~qv~'?'9~_~A.~ Address ~o/-.~/~.f~ ~ iF ~A ~,~,'z ~k, ~, ~_~; (k~ner/builder~_; ~__Tal~ephone o W o "45700 (e) Real Estate Co~ & Agent ~,~-~-~o.~ ~c~/:zp, ,~-~,~ .~.~,~ J.-/%,./~,j. Telephone (f) Mail the P~,A to the following address: T~ of Residence Single-Family~<'~ Number of Bedrooms Multi-Family Other (describe) Water Su~l~ Individual Well~ Communit~ Public ~ Mote: If community well system, must have ~itten confirmation from the State Department of Environmental Conservation attesting to the legality and status~ Sewage Disposal Onsite~ Public~ Community ~ Holding Tank~ Note: If community wall system, must have written confirmation from the State Department of Envirorm~ental Conservation attesting to the legality and status. [Page 1 of 2] 5o Engineerin~ Firm Providi~ns actions Tests_~__F_ile Search Data and ......... ~ ............. ~ ~ -- - .......... {-ion As certified by my seal affixed hereto and as of the validation date sh°--~"-, investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance ~th ~! Municipal and State codes~ ordinances~ and tions in effect on the date of this inspection. Address ~3 ~ /,~{ ~,~o~ ~ ~~ DHEP A_~r_ov al Approved for ~'5 bedrooms Approved~ Disapproved Terms of Conditional Approval CAUTION THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONmeNTAL PROTECTION (DHEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON T}~ E~EPRESENT- ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE- MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A CERTIFICATE IS ISSUED° ~{E MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS OR OMISSIONS IN %RtE PROFESSIONAL ENGINEER'S WORK° (DHEP SEAL) RR4/ej/D18 [Page 2 of 2] 7-19-84 WELL DATA Well Classification MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 Legal Description: ~o~ ~- ~//~' ~ If A, B, o~ C, D.E.C. Approved(Y/N) ~ ~-~ ,~ ~.~ Well Log P~esent (Y/N) .~//,~ Total Dept~. Cased to Static Water Level Casing Height Above Ground Electrical Wiring in Conduit (Y/N) Separation Distances frc~ Well: To Septic/Holding Tank on Lot To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line Cleanout/Manhole Wate~ Sample Collected By Water Sample Test Results Cc~ments Date Completed Pump Set At Depth of Grouting. Yie id Sanitary Seal on Casing (Y/N) Depression A~ound Wellhead (Y/N) ; On Adjoining Lots ; On Adjoining Lots To Nearest Public Sewer To Nearest Sewer Service Line on Lot ; Date B. SEPTIC/HOLDING TANK DATA Date Installed /~Y~ StandpipPs (Y/N) Depression Over Tank (Y/N) /L/ Date Last Pumped /./~- Pumping/Maintenance Contract on File (Y/N) ~V/~. ; for /4//.4 Holding Tank High-Water Alarm (Y/N) /~/.~ Temporary Holding Tank Permit (Y/N) Separation Distances f~om Septic/Holding Tank: To Water-Supply Well ~oo ~ To Building Foundation /o ! To P~operty Line /o '~ TO Disposal Field /~- / TO Water Main/Service Line ~/~ z Course ~J ~ Size /~z, ~'~ / No. of Cc~pa~tments Air-tight Caps (Y/N) .// Foundation Cleanout (Y~) To Stream, Pond, Lake, c~ Major D~ainage Corg~ants ~ '~.~ ~- [Page 1 of 2] 2-15-84 C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed /9 ~3 Width of Field / ~/ / Square Feet of Absc~ption A~ea --~ 6 ~ Depression ove~ Field (Y/N) /L] Length of Field /z/ Depth of Field ~ ~ Gravel ~d ~ick~ss Stan~i~s ~e~nt ~te of ~st ~a~ Test Results of Last Adequacy Test 3~7',~ f~.~-~? J~ ~' ~,~',~ze~'~ /~ Separation Distance f~om Absorption Field: To ~te=-Supply Well ~ OD ~ To P~operty Line '7 o / To Buildin~ Foundation ~-? To Existing or Abandoned System on Lot /~/~ ; On Adjoining Lots To Water Main/Se=vice Line /z)e To Cutbank(if present) To Stream/Pond/Lake/or Majo= D~ainage Ccu~se To D~iveway, Pa~kin~ A~ea, or Vehicle Storage Area /~ / De LIFT STATION /~ Date Installed Size in Gallons "Pump On" Level at High Wete~ Alarm Level at Tested fo~ Electrical Codes(Y/N) Dir~nsions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles du~ing Adequacy Test. Meets MOA C~,~ents ** Check Pe=mitted Bedroom Rating Against HAA R~quest I certify that I have checked, verified, c~ confom~ed to all MOA HAA Guidelines in effect MOA No. on the date of this inspection. KB1/d5/s [Page 2 of 2] 2-15-84 [~,~T E RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME INSPECTOR INSPECTOR INSPECTOR MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE ENVI RONMENTA L SANITATION DIVISION Telephone 264-4720 BI RECTIONS: Complete all parts on page ~. Incomplete requests will not be processed, Please allow ten (10) days for processing. MAILING A RESS d" MAILING ADDRESS 3, LENDING INSTITUTION ' PHONE 4, REALTOR/AGENT ~ /~ I PHONE MAILING ADDRESS 5. LEGAL DESCRIPTION 6. TYPEOF RESIDENCE [~ SINGLE FAMILY ID MULTIPLE FAMILY 7. WATER SUPPLY [] INDIVIDUAL* COMMUNITY PUBLIC UTI LITY NUMBER OF~BEGROOMS [] One [] Four [] Other [] Two [] Five ~. Three [] Six ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM '[~ INDIVIDUAL/ON-SITE** ~(~"'~.5 YEAR ON-SITE SYSTEM WAS INSTALLED. [] PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCO,MI~ANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED, 1- II rills SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVI DUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTI LITY Connection Verified LOG RECEIVEO 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER []INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY ~ --7 --~ Connection Verified INSTALLER []Septic Ta.~k or [~]Holding Tank Size: /(~ If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AR EA MATERIAL 4, DISTANCES Septic/Holding Tank Absorption Area 8ewer Line I Nearest Lot Line WELL TO: Absorption Area to nearest Lot Line 5, COMMENTS PROVEDFO BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED DATE BY 72-010 (Rev, 6/79) EXCAVATION ROBERT A. SHAFER WORK November 29, 1981 CIVIL ENGINEER 694-2979 MUNICIPALITY OF ANCHORAGE PEP}. OF HEALTil & ENVIRONMENI'AL P,iOTECTION Grace Campbell P.O. Box 1665 0~i{]/.~ 1981 Eagle River, Alaska 99577 'Dear Mrs. Campbell, Reference: Lot 5: Block 2: Wynter Park subdivision A sewer system adequacy test was performed on the system located on the referenced property as you requested. The septic tank was pumped and verified to have a capacity of 1000 gallons. The seepage pit was charged with 1000 gallons of fresh water and after a period of 24 hours all the water which had been added to the crib had percolated out. It can be concluded from this test that the waste water disposal system serving the three bedroom residence located on this property is currently functioning adequately. However this system cannot be guaranteed against subsequent failure. If we may be of further service, please do nS/ss /. _ - Cc: First kfationa! Bank of ADch~3f-.age Eagle River Branch not hesitate to call. Municipality of Anchorage Department of Health and Environmental Protection SRB 196X EAGLE R~VER, ALASKA ADEQUACY TEST WATER AND SEWER INSPECTION WELL INSPECTIONS AN D FLOW TEST SITE PLANS ROAD DESIGN SOIL TEST ON S~TE WASTE WATER DISPOSAL SYSTEM DEStGN EXCAVATION WORK ROBERTA. SHAFER January 8, 1984 CIVIL ENGINEER 694-2979 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION JAN 9 Dynamic Realty ATTENTION: Barbara Deloney P.O. Box 1796 Eagle River, Alaska 99577 RECEIVED Dear Ms. Deloney, Reference: Lot 5: Block 2: Wynterpark subdivision A sewer system adequacy test was performed on the system located on the refenced property, as you requested. The septic tank was pumped and verified to have a capacity of 1000 gallons. The seepage pit was charged with 700 gallons of fresh water and after a period of 24 hours 510 gallons had percolated out of the crib. It can be concluded from this test that the waste waster disposal system serving the three bedroom residence located on this property is currently functioning adequately. However, the system cannot be guaranteed against subsequent failure° If we may be of further service, cc: Municipality of Anchorage Department of Health and Environmental please do not hesitate to call. Protection SRB 196X EAGLE RIVER, ALASKA 99577 825 'l i\NCI{ONA(~I , Al A',;I</\ !)9501 (~)07} 264 4 I November 4, 1981 Thomas H./Grace E. Campbell Post Office Box 1665 Eagle River, Alaska 99577 Subject: Lot 5 Block 2 Wynter Park Subdivision Approval for the individual sewer and water facilities cannot be granted until the following items have been completed: (1) The septic tank pumped with a receipt submitted to this office. (2) An adequacy test needs to be performed on the existing leaching area. This test will determine if the system is adequate according to National Standards. A listing of private firms performing the test is enclosed. This report needs to be submitted to this office for our review. If there are any further questions, please call this office at 264-4720. Sincerely, Robert C. Pratt, R.S. Associate Specialist RCP/ljw RILL SHEFFIELD, GOVERNOR DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, ALASKA 99501 Telephone: (907) Address: 274-2533 To Whom it May Concern: According to records 6n file in this office the ~//~ Water System is in compliance.with the State Drinking / Water Regulations Sincerely,