HomeMy WebLinkAboutWYNTER PARK #1 BLK 2 LT 15  MUNICIPALITY OF ANCHORAGE DEPARTIVIENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchora,qe, A as <a 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ~ ,~ DISTANCE TO: WoH/J]. ~1~ ~ i" No, of lines/ Length~ li~ Total le~f inches Length Width ~epth ~ PERMIT NO, ~ Well Building foundation Nearest lot line OTHER PIPE MATERIALS 72-~ 3 (Rev. 3/78) QGRE ''R ANCHORAGE AREA BOr' Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 'GH INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM MAILING ADDRESS ~XI~- (~("~I.'LI~ PHONE SEPTIC TANK: DISTANCE FROM WELL MANUI:ACTU RER ~:/'YL[/( MATERIAL '~'-//*(~ (¢ f-- NUMBER OF COMPARTMENTS ,~- INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY. /()~2~(2 GALLONS. SEEPAGE PIT: NUMBER OF PITS LINING MATERIAL _~, __, BUILDING FOUNDATION__ ADDITIONAL ABSORPTION BIAMETER 5~ OR WIDTH Ill', LENGTH I¢, DEPTH CRIB SIZE: DIAMETER. ~" DEPTH ~,~! DISTANCE FROM: WELL TOTAL EFFECTIVE ., NEAREST LOT LINE __ ABSORPTION AREA (WALL AREA) _ SQ, FT. WELL: TYPE BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION DEPTH DISTANCE FROM: NEAREST NEAREST SEPTIC SEEPAGE LOT LINE SEWER LINE TANK SYSTEM OTHER SOURCES DISAPPROVED REMARKS DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: t ~tc1 -~ PiPE MATERIAL: LOT SLOPE: REMARKS: __ Form No, EQ-031 DATE PERMIT NO. 825 "L'" STREET,. FINCHORFIGE, FIK. 995Ett 264-4?20 Oi'-~--"--=:] Z 'l-E SEI---IER LIF"IZiF~,.-F~L'-.E F"E ~-%':1"1 Z -r < 82104t ) BPPLICRNT LOCRT I ON LEGRL JRMES CLOYD LiS B2 WYNTER PRRK 6015 PRRK DR CFIUGIRK 99567 LOT SIZE 999999 SQUBRE FEET TYPE OF SOIL ABSORPTION SYSTEM IS: DRRINFIELD MR,~Ii"IUM NUMBER OF' BEDROOMS SOIL RRTING <S6~ FT/BR)= 158 THE REQUIRED SIZE OF' THE SOIL RBSORPTION SYSTEM IS: [:, E~ [-~ "F l.-I = 5 L_ E I'-.[ G 1- F! = ~ 3: G R ~--t %.' ~Z L_ E:, E P T H = ~: THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD. THE DEPTH OF' R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE GROUND RND THE BOTTOM OF THE EXCR',/RTION (IN FEET:). '[i-~E ]"RENC:~ ~--3 I El, TH I ~; ~l. 1~88 F-EET. THE GRBVEL DEPTH IS THE MINIMUM DEPTH OF GRBVIEL BETWEEN THE OUTFRLL PIPE RND THE BOTTOM OF THE E~'(CRVRTION (IN FEET). F'ERMIT RPPLICFINT HRS THE RESPONSIBILITY TO INFORM THIS DEPRRTMENT DURING THE IN~TRLL. R"I'ION INSPECTIONS OF RNY WELLS RDJRCENT TO 'THIS PROPERTY I~ND THE NUMBER OF RESIDENCES THRT THE WELL WILL SERVE. BRCKFILLING OF RNY SYSTEM WITHOUT FINRL. INSPECTION RND RPPROVRL BY THIS; DEF'RRTMENT WILL BE S:;UBJECT TO PROSECUTION. MINIMUM DISTRNCE BETWEEN R WELL RND RN¥ ON-SITE SEWRGE DISPOSRL SYSTEM IS 100 FEET FOR R PRIVRTE WELL OR ±50 TO 200 FEET FROM R F'LIBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC: WELL MINIMUM DISTRNCE FROM R PRIVRTE WELL TO FI PRIVR'FE SEWER LINE IS 25 FEET RND TO R COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS MRY RPPLY. SPECIFIC:RTIONS RND CONSTRUCTION DIRGRRMS FIRE BVRILFIBLE TO INSURE PROPER INSTRLLFITION. F"ERI',I Z T' E::-::F' Z RES DEE:EI~.IE:E=_[~. I CERTIFY THRT :'L: I BN FRMILIRR WITH THE RE~.UIREMEN]'S FOR ON-SITE SEWERS RND WELLS RS SET FORTH BY THE MUNICIPRLITY OF RNCHORRGE. 2: I WILL INSTFILL ]"HE SYSTEM IN RCCORDRNCE WITH THE CODES. -"::~: I UNDERSTRND THFIT THE ON-SITE SEWER SYSTEM f"IRY REQUIRE ENLRRGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THBN ]: BEDROOMS. V4. ~,]~ SOILS LOG PERFORMED FOR: LEGAL DESCR,PTION: ~'' 1 · 4 ~ 5 6 7 8 9 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 h. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST [] PERCOLATION TEST DATE PERFORMED:J~~,'~*~(~'~ SITE PLAN 10 11 12 13- 14- 15- 16- 17- 18- 19- 20- COMMENTS WAS GRO..OWATER YZ 3' [ ENCOUNTERED? ~ 0 IF YES, AT WHAT ? / P E DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~ [ [ 'Y~ (minutes/inch) / TEST RUN BETWEEN __ FT ¢~te actor Comments Time Date inspector Date Sewer Installed Soils Rating 3tor Conditional Approval i '-'"3-. tOA¢ Permit No. Well To Absorption Area Well to Tank Septic Tank Size Holding Tank Size Well Log Received APPLICANT FILLS OUT LOWER HALF ONLY Buyer Address Lending ~nstltutlon Realty Co & Agent %~j~,~, ~ '~ -- ~ ~- ~' ' Typ~ Residence ~ ~ Single Family B Multiple Family No. of Bedrooms ~_ ~ Other tPhone ipply (4~1¢lndlvidual Community [] Public Utility_ ATTACH WELL LOG. A well Icg is required for all wells drilled since June 1975. For wells drilled prior to that date, give well depth (attach Icg If available.) - Se'4.~ Disposal Year Individual Installed; _ /¢ Individual When Connected to Public Utility:_ E] Public Utility --~ KJ Holdin! Tank NOTE: THE INSPECTION FEE MUST AccOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. james P' & Carolyn If' C].Oyd ~,~ ~OX 6346 Pa:L¥~t~r, ~ 99G45 SubJect: Lot 15, 'BloCk 2, Wynter park Dear Mr. & Mrs. properly and an ul?'~fade will be system i,~ not functioning · ' ' necessarY' ~ ~ soils te~h w~.l~=be required so that :if there are any fur%t~er (~ues%iO~, please call. this office sincerelY, Robert C. pratt ~ fJpecialist AssoCiate Env]ronmenta~ RCP/Cl January 22, 1982 James & Carolyn Cloyd SRA Box 6346 Pa ll'~er, AK 99645 Subject: Lot 15, F, loek 2, Wynter Park S/D Dear Mr. & Mrs. Cloyd: Approval for the individna], sewer and water facilities cannot be granted antil the fei. lowing items 'hav,~ been eomplo..ted.. 'J.'he septic tank pumped wi'th a receipt submitted to this epa r't?nent. An adequacy test needs 'to be performed on the e×isting leaching area. '~'his test will determine if the system is adequate according to National Standards. A listing of private firms performing the test is enclosed. ~£his report needs to be submitted to this office for our' review. Please notify this d~-partment for a reinspection when the noted discrepancies have been corrected. If there are any further questions, please call this offi(~e at 264-4720. Sincerely, I':nclosllre Robert C. Pratt Associate Environmental ..qpecia].ist EXCAVATION ROBERT A. SHAFER WORK February CIVIL ENGINEER 694.2979 ].982 MUNICIPALITY OF ANCI4ORAGE Myrtle Allen Totem Realty Dear Ms. Allen, Reference: RECEIVED Lot 15: Block.~, Wynter Park Subdivision A sewer system adequacy test was performed on the system located on the referenced property as you requested. The septic tank was pumped and verified to have a capacity of 1000 gallons. The seepage pit was full of water and approximately 650 gallons had to be removed. The system was then recharged and after a period of 24 hours, measurements taken indicate that none of the water had percolated out of the system. It can be concluded from this test that the waste water disposal system serving the two bedroom residence located on this property is not functioning adequately and will require complete replacement with a Municipality approved system. If we may be of further service, please do not hesitate to call. Sincerely, cc: First National Bank of Anchorage ATTENTION: Catherine Gust Municipality~of Anchorage Department of Health and Environmental Protection SRB 196X EAGLE RIVER, ALASKA