HomeMy WebLinkAboutWYNTER PARK #1 BLK 2 LT 15
MUNICIPALITY OF ANCHORAGE
DEPARTIVIENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchora,qe, A as <a 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
~ ,~ DISTANCE TO: WoH/J].
~1~ ~ i" No, of lines/ Length~ li~ Total le~f
inches
Length Width ~epth ~ PERMIT NO,
~ Well Building foundation Nearest lot line
OTHER
PIPE MATERIALS
72-~ 3 (Rev. 3/78)
QGRE
''R ANCHORAGE AREA BOr'
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
'GH
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
MAILING ADDRESS ~XI~- (~("~I.'LI~ PHONE
SEPTIC TANK:
DISTANCE
FROM WELL
MANUI:ACTU RER ~:/'YL[/(
MATERIAL '~'-//*(~ (¢ f-- NUMBER OF
COMPARTMENTS ,~-
INSIDE LENGTH
INSIDE WIDTH
LIQUID DEPTH
LIQUID CAPACITY. /()~2~(2 GALLONS.
SEEPAGE PIT:
NUMBER OF PITS
LINING MATERIAL _~, __,
BUILDING FOUNDATION__
ADDITIONAL ABSORPTION
BIAMETER 5~ OR WIDTH Ill', LENGTH I¢, DEPTH
CRIB SIZE: DIAMETER. ~" DEPTH ~,~! DISTANCE FROM: WELL
TOTAL EFFECTIVE
., NEAREST LOT LINE __ ABSORPTION AREA (WALL AREA) _
SQ, FT.
WELL:
TYPE
BUILDING
FOUNDATION
CESSPOOL
APPROVED
CONSTRUCTION DEPTH DISTANCE FROM:
NEAREST NEAREST SEPTIC SEEPAGE
LOT LINE SEWER LINE TANK SYSTEM
OTHER SOURCES
DISAPPROVED REMARKS
DISTANCES:
DIAGRAM OF SYSTEM
INSTALLED BY:
t ~tc1 -~
PiPE MATERIAL:
LOT SLOPE:
REMARKS: __
Form No, EQ-031
DATE
PERMIT NO.
825 "L'" STREET,. FINCHORFIGE, FIK. 995Ett
264-4?20
Oi'-~--"--=:] Z 'l-E SEI---IER LIF"IZiF~,.-F~L'-.E F"E ~-%':1"1 Z -r
< 82104t )
BPPLICRNT
LOCRT I ON
LEGRL
JRMES CLOYD
LiS B2 WYNTER PRRK
6015 PRRK DR CFIUGIRK 99567
LOT SIZE 999999 SQUBRE FEET
TYPE OF SOIL ABSORPTION SYSTEM IS: DRRINFIELD
MR,~Ii"IUM NUMBER OF' BEDROOMS
SOIL RRTING <S6~ FT/BR)= 158
THE REQUIRED SIZE OF' THE SOIL RBSORPTION SYSTEM IS:
[:, E~ [-~ "F l.-I = 5 L_ E I'-.[ G 1- F! = ~ 3: G R ~--t %.' ~Z L_ E:, E P T H = ~:
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD.
THE DEPTH OF' R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF THE
GROUND RND THE BOTTOM OF THE EXCR',/RTION (IN FEET:).
'[i-~E ]"RENC:~ ~--3 I El, TH I ~; ~l. 1~88 F-EET.
THE GRBVEL DEPTH IS THE MINIMUM DEPTH OF GRBVIEL BETWEEN THE OUTFRLL PIPE
RND THE BOTTOM OF THE E~'(CRVRTION (IN FEET).
F'ERMIT RPPLICFINT HRS THE RESPONSIBILITY TO INFORM THIS DEPRRTMENT DURING THE
IN~TRLL. R"I'ION INSPECTIONS OF RNY WELLS RDJRCENT TO 'THIS PROPERTY I~ND THE
NUMBER OF RESIDENCES THRT THE WELL WILL SERVE.
BRCKFILLING OF RNY SYSTEM WITHOUT FINRL. INSPECTION RND RPPROVRL BY THIS;
DEF'RRTMENT WILL BE S:;UBJECT TO PROSECUTION.
MINIMUM DISTRNCE BETWEEN R WELL RND RN¥ ON-SITE SEWRGE DISPOSRL SYSTEM IS
100 FEET FOR R PRIVRTE WELL OR ±50 TO 200 FEET FROM R F'LIBLIC WELL DEPENDING
UPON THE TYPE OF PUBLIC: WELL
MINIMUM DISTRNCE FROM R PRIVRTE WELL TO FI PRIVR'FE SEWER LINE IS 25 FEET RND
TO R COMMUNITY SEWER LINE IS 75 FEET.
OTHER REQUIREMENTS MRY RPPLY. SPECIFIC:RTIONS RND CONSTRUCTION DIRGRRMS FIRE
BVRILFIBLE TO INSURE PROPER INSTRLLFITION.
F"ERI',I Z T' E::-::F' Z RES DEE:EI~.IE:E=_[~.
I CERTIFY THRT
:'L: I BN FRMILIRR WITH THE RE~.UIREMEN]'S FOR ON-SITE SEWERS RND WELLS RS SET
FORTH BY THE MUNICIPRLITY OF RNCHORRGE.
2: I WILL INSTFILL ]"HE SYSTEM IN RCCORDRNCE WITH THE CODES.
-"::~: I UNDERSTRND THFIT THE ON-SITE SEWER SYSTEM f"IRY REQUIRE ENLRRGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THBN ]: BEDROOMS.
V4. ~,]~
SOILS LOG
PERFORMED FOR:
LEGAL DESCR,PTION: ~''
1
· 4
~ 5
6
7
8
9
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 h. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
[] PERCOLATION
TEST
DATE PERFORMED:J~~,'~*~(~'~
SITE PLAN
10
11
12
13-
14-
15-
16-
17-
18-
19-
20-
COMMENTS
WAS GRO..OWATER YZ 3' [
ENCOUNTERED? ~ 0
IF YES, AT WHAT ? / P
E
DEPTH?
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE ~ [ [ 'Y~ (minutes/inch)
/
TEST RUN BETWEEN __ FT
¢~te
actor
Comments
Time
Date
inspector
Date Sewer Installed
Soils Rating
3tor
Conditional Approval
i '-'"3-. tOA¢
Permit No.
Well To Absorption Area
Well to Tank
Septic Tank Size
Holding Tank Size
Well Log Received
APPLICANT FILLS OUT LOWER HALF ONLY
Buyer
Address
Lending ~nstltutlon
Realty Co & Agent %~j~,~, ~ '~ -- ~ ~- ~' '
Typ~ Residence ~
~ Single Family
B Multiple Family No. of Bedrooms ~_
~ Other
tPhone
ipply
(4~1¢lndlvidual
Community
[] Public Utility_
ATTACH WELL LOG. A well Icg is required for all wells drilled since June
1975. For wells drilled prior to that date, give well depth (attach Icg If
available.) -
Se'4.~ Disposal Year Individual Installed; _
/¢ Individual When Connected to Public Utility:_
E] Public Utility --~
KJ Holdin! Tank
NOTE: THE INSPECTION FEE MUST AccOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
james P' & Carolyn If' C].Oyd
~,~ ~OX 6346
Pa:L¥~t~r, ~ 99G45
SubJect: Lot 15, 'BloCk 2, Wynter park
Dear Mr. & Mrs.
properly and an ul?'~fade will be
system i,~ not functioning · ' '
necessarY' ~ ~ soils te~h w~.l~=be required so that
:if there are any fur%t~er (~ues%iO~, please call. this office
sincerelY,
Robert C. pratt ~ fJpecialist
AssoCiate Env]ronmenta~
RCP/Cl
January 22, 1982
James & Carolyn Cloyd
SRA Box 6346
Pa ll'~er, AK 99645
Subject: Lot 15, F, loek 2, Wynter Park S/D
Dear Mr. & Mrs. Cloyd:
Approval for the individna], sewer and water facilities cannot
be granted antil the fei. lowing items 'hav,~ been eomplo..ted..
'J.'he septic tank pumped wi'th a receipt submitted to this
epa r't?nent.
An adequacy test needs 'to be performed on the e×isting
leaching area. '~'his test will determine if the system is
adequate according to National Standards. A listing of
private firms performing the test is enclosed. ~£his report
needs to be submitted to this office for our' review.
Please notify this d~-partment for a reinspection when the
noted discrepancies have been corrected. If there are any
further questions, please call this offi(~e at 264-4720.
Sincerely,
I':nclosllre
Robert C. Pratt
Associate Environmental ..qpecia].ist
EXCAVATION
ROBERT A. SHAFER
WORK
February
CIVIL ENGINEER
694.2979
].982
MUNICIPALITY OF ANCI4ORAGE
Myrtle Allen
Totem Realty
Dear Ms. Allen,
Reference:
RECEIVED
Lot 15: Block.~, Wynter Park Subdivision
A sewer system adequacy test was performed on the system located
on the referenced property as you requested. The septic tank was
pumped and verified to have a capacity of 1000 gallons. The seepage
pit was full of water and approximately 650 gallons had to be removed.
The system was then recharged and after a period of 24 hours, measurements
taken indicate that none of the water had percolated out of the system.
It can be concluded from this test that the waste water disposal
system serving the two bedroom residence located on this property is
not functioning adequately and will require complete replacement
with a Municipality approved system.
If we may be of further service, please do not hesitate to call.
Sincerely,
cc: First National Bank of Anchorage
ATTENTION: Catherine Gust
Municipality~of Anchorage
Department of Health and Environmental
Protection
SRB 196X EAGLE RIVER, ALASKA