Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WILDWOOD BLK 1 LT 1
Lo )CATION MUNICIPALITY OF ANCHORAGE r DEPARTMENT OF HEALTH & ENVIRONMENTAl- PROTECTION ENVIRONMENTAl- ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAl- SYSTEM AND/OR WELl. INSPECTION REPORT '40. OF BE,~OOMS DISTANCE TO: -- ~terial No. of compartments h]side length qidth -- depth IF HOMEMADE: {MIT NO. DISTANCE TO: Material Liquid capacity in gallons Manufacturer lit NO. mdation e / DISTANCE TO: width nce between lines No. of lines Length of eac~..~ TotaJ length of inches__ al beneath tile Depth NEW UPGRADE Type of crib ~ diameter Crib depth fou Nearest lot line Well DISTANCE TO: Distance to iht line Class Depth Driller foundation r line Septic tank DISTANCE TO: I effective absorption area rea(s) OTHER RIALS RATING INSTALLER APPROVED DATE LEGAL 2-013 (Rev. 3/78) PERMIT NO. RPPLtCRNT LOCRTION LEGRL RICHRRD H OLSEN LiBi WILDWOOD 2~0t LINCOLN RVE 9950~ LOT SIZE 248-~8~6 999999 SQURRE FEET TYPE OF SOIL RBSORPTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = 4 SOIL RATING (SQ FT?BR)= 200 THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: [)EPTH= t~ LEr'~GTH= 67 GR~%"'EL [)EPTH= 6 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRAVEL DEPTH IS THE MINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE RND THE BOTTOM OF THE EXCBVRTION (IN FEET). F:EQLI I F:ED SEF"T I ,2: TRr-~--:] S I ZE= 1250 GRLLC,~-~S PERMIT APPLICANT HRS THE RESPONSIBILITY TO INFORM THIS DEPRRTMENT DURING THE INSTRLLATION INSPECTIONS OF 8NY WELLS ADJACENT TO THIS PROPERTY AND THE NUMBER OF RESIDENCES THAT THE WELL WILL SERYE~ TL~£" (2) I ~-~SPE£:TI,]~-~S RRE F~EQL~IREC~ BACKFILLING OF RNY SYSTEM WITHOUT FINAL INSPECTION RND RPPROVRL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTRNCE BETWEEN R WELL RND ANY ON-SITE SEWRGE DISPOSAL SYSTEM IS 100 FEET FOR R PRIVATE WELL OR t50 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DIST8NCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET ~ND TO ~ COMMUNITY SEWER LINE IS 75 FEET~ OTHER REQUIREMENTS M8Y APPLY. SPECIFIC8TIONS AND CONSTRUCTION DIBGR8MS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F'E~:M I T E:=-~P I ~'ES DE£:E~4BEF-: ~-1__.. t~82 I CERTIFY THRT ±: I RM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET FORTH BY THE MUNICIPALITY OF RNCHORRGE. 2: I WILL INSTALL THE SYSTEM IN ACCORD8NCE WITH THE CODES. }: I UNDERST8ND TH8T THE ON-SITE SEWER SYSTEM MRY REQUIRE ENLRRGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THRN 4 BEDROOMS. RPPLICRNT RICHRRD H OLSEN V4. 0 MUNICIPALITY OF ANCHORAGE Heath and Environmental Prot(~jiion Fourth Floor West 825 L Street Anchorage, Alaska 99501 264-4720 INSPECTION REPORT ON 51TE SEWAGE DISPOSAL SYS?EM LOCATION-~OlOq- %J¥cLk/~t ~ LEGAL OESCRIPTION SEPTIC TANK: DISTANCE FROM WELL--' INSIDE LENGTH _~ C~ ~)/~l~,~.&;4 ~o,v ~ fED% NUMBER OF MANUFACTURER MATERIAL COMPARTMENTS INSIDE WIDIH ~11 LIQUID DEPTH LIQUID CAPACITY ~'~ ~ GALLONS. TILE DRAIN FIELD: DISTANCE FROM WELL FOUNDATION NEAREST LOT LINE TOTAL LENGTH _OF LINE # of Lines DISTANCE BETWEEN LIIqES TRENCH WIDTH IN. TOTAL EFFECTIVE ABSORPTION AREA__ SQ. FT. LENGTH OF EACH LINE DEPTH OF FILTER ©EPTII: TOP OF TILE TO FINISH GRADE MATERIAL BENEATH TILE IN. ABOVE TILE IN. SEEPAGE PIT: Log Crib Rings BUILDING FOLJNDATION. DIAMETER OR WIDTH LENGTH DEPTH Crib S~e: DIAMETER___DEPTH DISTANCE FROM: TOTAL EFFECTIVE NEAREST LOT LINE__ WELL ABSORPTION AREA (WALL AREA) SQ. FT. Well Class: Depth: Well Distance To: Lot Line Bldg: Sewer Line: __ Pipe Materials: # of Bedrooms: Installer: Remarks: DATE APPROVED -- J i i "FTq /MUNICIPALITY OF ANCHORAGE He/~;~h~ and Environmental Prot( /'ion Fourth Floor West ~ 825 L Street Anchorage, Alaska 99501 264-4720 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM MAILING ADDRESS '~\\~ ~'~\%~'~ SEPTIC TANK: DISTANCE ~L~t$'~ ~("%~_PJk~ NUMBER OF PROM WELL ~L~"% L3.'~ £~ _ MANUFACTURER , "P~-'~'r~'~%'60'7--~L MATERIAL 'E~ __COMPARTMENTS_~'~'AJ-, ,~,_~ · INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY% ~,~ GALLONS. TILE DRAIN FIELD: DISTANCE FROM WELL FOUNDATION ___ NEAREST LOT LINE_ TOTAL LENGTH OF LINE ~ of Lines DISTANCE BETWEEN LINES ,TRENCH WIDTH---- IN. TOTAL EFFECTIVE ABSORPTION AREA DEPTIh TOP OF TiLE TO FINISH GRADE SQ. FT. LENGTH DP EACH LINE ©EPTit OF FILTER MATERIAL GENEATH TILE IN. ABOVE TILE IN. SEEPAGE PIT: Log Crib Rings BUILDING FOUNDATION DIAMETER -- OR WIDTH LENGTH DEPTH Cri~ Si'ze: DIAMETER___DEPTH . DISTANCE FROM: WELL TOTAL EFFECTIVE NEAREST LOT LINE ABSORPTION AREA (WALL AREA) SQ. FT. well Class: Depth: Well Distance To: Lot Line Bldg: Sewer Line: Pipe Materials: # of Bedrooms: Installer: Remarks: INSPECTION REPORT ON~E S~WAGE DISPOSAL SYSTEM PA.# Name ~/ ~Mailing Address :-~ ~... ...... Locatton~ ~F~~ ,, Legal DeScription,. ~/~, / 8g/ ,~'CD~°°D~ ~, , sEPTIc TANK: Distance fmom well ,Matemial ~ ,.N~em of compartments Liquid capacity/~ gallons. Inside length ~ Inside width ~" Liquid depth, SEEPAGE SYSTEM: Seepage Pit~ Nu~em of pits~ .,Outside dia~e~ ~, ,, / width., .,, length .... . depth. ~ ,,, llninE ma%e~ial ~O~ ... Diet.ce from Well building fo~dation ,,, , nea~es~ lo~ line. To. al effective absorption amea (wall a~ea) ~ sq. ft. TILE DRAIN FIELD: Distance~fPom well , fo~dation ~ nearest lot line Total len~h of lin~s Nu~em of lines Distance between lines Tmeneh width Depth: tile WELL: lot line cesspool_. __ina Total effective absorption area~q, ft. Length of each llne Top of tile to finish grade, Depth of filter material beneath in. Above tile Type~,~, , depth . distance f~om building foundation . . nearest ... ~ nearest sewe~ line,, , septic tank, , seepage system ~ , DISTANCES 4.7 DIAGRAM OF SYSTEM DATE: APPROVED Health AuthoPity MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVl RONMENTAL PROTECTION Pouch t~650, Anchorage, Alaska 99502 276-2221' SOILS LOG - pERcOLATION TEST '~ SOILS LOG [] PERCOLATION TEST 13- 14= 15- 16 17 18 19 20 DATE PERFORMED: WAS GROUND WATER ~ ~ ~L ENCOUNTERED? .- '- IF YES, AT WHAT DEPTH? Gross Net Depth to ' Net Reading Date Time Time Water Drop I PERCOLATION RATE minutes/inch) TEST RUN BETWEEN FT AND , FT P~RFORMEDBY' ~ ~ [ ~ CERTIFIED BY: ~/~..~f~ DATE( ~' ~/O ~/ AND AssoCIATES, INC. John M. Lambe, P.E. 7127 Old Seward Highway · Anchorage, Alaska 99502 GEOTECHNICAL ENGINEERING AND TESTING 907-349-6531 LETTER OF TRANSMITTAL TO: Richard Olson ATTENTION: SUBJECT: Lot 1, Block 1, W~.ldwood Subdivision OUR JOB NO. Transmitted herewith is/are the following: Percolation Test performed on the above referenced property.on April 17, 1978. Be advised that fluctuations in free water levels may occur and may not be represented~on this parSicular test. CC: JOHN M. LAMBE AND ASSOCIATES DATE 0 t er 11, 1982 W, 78 /'- DRIVE ~, J L~' ~'"1 AVE. ?£EASRNT ~R. W. ' ~4 AVE _,0 ~ ~ ~ / //~//0; I I I I ~" ~d? '~' "~', L _ JpRj~ (~us,sm,~,~' [ ~ OPAL ~- ='q' I I i I I II 132 112 131 144 Sandleke Area Reference Map-PlO (~ 1974 JH SIGNED DATE R e di~,p r m ® 4S 469 Poly Pak 150 sels) 4P469 DETACH AND FiLE FOR FOLLOW-UP August 22~ 1977 James R. Miller 2902 Strawberry Road Anchorage, Alaska 99502 Re lot 1 block 1 Wildwood Subdivision on-site sewer Per our discussions this date in ~eference to the on-site sewer system located on the above cited property. The following upgrade is required: A deep trench per the typical drewtngs provided you this date. This trench to be at adept that is 12" below the bottom of the ex~sting seepage pit, , backhoe bucket~width and a total of 50' (fifty feet) in length. The trench is to begin at the outer edge of the existing pit and be backftlled wtth screened gravel 1/2~' to 2 1/2" diameter to.? dep~h.~f 6'.(st~,f?t). A sottd pipe should be run from a point belew ~ne exlst~ng p~pe ~ua~ runs into the seepage rings from the se~tc tank to ~he new trench and then 4" perf p~pe laid on top of the gravel backftll per the above described drawings. % will no__~require the septic tank to be exposed. A permit to upgrade the existing system must be obtained from this ~ffice. The fee for this permit is $20.00. If there is any questions please contact this office, Joseph S. Blatr Envfronmental Sen=ices Manager L~;MUNICIPALITY OF ANCHORAG~ ~ DEPARTMEN~ ~F HEALTH AND ENVIRONMENT~_wPROTECTION 825 ~L~ Street, Anchorage, Alaska 99501 279-2511, ext. 224 or 225 Date Received: ti2: I~ J-m e __~_, .?_ ~__/'~//__$ ~,3: Time Insp ~-~-.-~A_-- insp o'7 7 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER .AND WATER FACIiLITIES 1. Lending Institution Request: Mailing Address: 2. Property Owner: ~~,__~~ Mailing Address: .__~ Legal Description: Single Family Residence: Multiple Family Residence: ( Phone: Number of Bedrooms: ~ ~.~ Number of Bedrooms: Depth of Well 5. Well System: Individual well ( ) Community/Public System (~" ~;/~'~ Permit'9 Well Log on File ( ) Construction Bacterial Analysis 6. Sewage Disposal System: On-site System ( ) Public Utility ( ) Permit # Installed Installer Septic Tank Size Manufacturer Absorption Area Soils Rate Material Distances: Well to Septic Tank to Absorption Area to SeWer Line Nearest Lot line Absorption Area to Nearest Lot Line Department of Health and Environmental Protection Request for Approval of Individual Sewer and Water Facilities Affadavit Attached: ( ) Approved: Disapproved: ~ Letter Attached: Date: Date: ~7~77 20, 1974 P. O. BOX 720 99510 ~ se~vin~ Lot 1, Bloc/~ 1, wilda~od Subdivision Taylor proDer.~/ - 2902 Strawberry P~ad B~for~ this Depar~f~nt can giv~ lo~n approval on the subject syst~a we will n~ed the follc~ing /nform~tion: 1} A diagram of your ~ys~ in~l~{~g l~ne material and 1~ of ~o ~ ~d ~e pit. 2) ~e sl~ of ~ sep~ ~. 3) ~e s~ of t~m ~ge pit ~ ~e ~ ~ s~ of ~e ~ ~ ~ pit. 4) ~'~t ~ of ~1 ~ s~e pit is ~. If yo~ have any questi(~s, plem~e feel f~ee to conta~ me at 274-4561, ~n~ion 137. Sinc~ly, Bober~ C. Pratt, ~mW~x~m~l Cc~I Officer III ~ ~ ~. Taylor GREATER ANCHORAGE AREA BOROUGH Department of Environmental Quality 3330 "c" Street, Anchorage, Alaska 99503 274-4561 Date Received /~//×~//%~ Time of Inspection ~,'0o Date of Inspection REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES FOR 1. Approval requested by: Mailing Address: 2. Property Owner: ~ ~ Phone: Mailing Address: 3. Legal Description: ~z~_~ ~ 7~ / 4. Location: 5. Type of facility to be inspected 6. Well Data: No. of bedrooms C. Construction ~? Sewage Disposal System: ~. A. Installed B. B. Depth D. Bacter.ial Analysis Installer C. Septic Tank: 1. Size D. Seepage Pit: 1. Absorption Area Manufacturer 2. Material E. Disposal Distances: A. Well to: Field: Total length of lines ~eptic tank , Absorption area , Sewer Lines Nearest lot line , Other contamination B. Foundation to septic tank , Absorption area C. Absorption area to nearest lot line EQ-034 (1/74) Page 1 of two pages for Approval of Individual~_~'er & Water Facilities Page 2 of ~wo pages ~al Description Approved ~-~,~/~- Disapproved Date /~,~,~..~.~y~f Approval Valid for one year from date signed Greater Anchorage Area Borough, Department of Environmental Quality DIAGRAM OF SYSTEM I certify that the information contained in this request for approval to be a true and accurate representation of the subject sewer and water facilities and these facilities are operating satisfactorily. SIGNED Date EQ-034 (1/74) 333O 'GREATE,( ANCHORAGE ARE/, BOROUGH Department of Environmental Quality "C" St., Anchorage, Alaska 99503 274-4561 REQUEST- FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES 2. Property Owner: Hailing Address: 3. Name of Buyer: Hailing Address: Name Type of Inspection: CMRO VA x FHA CONV Gene H. Taylor 2902 Strawberry Road James R. Miller Day Phone 1200 Dimond Blvd. ~1459 Day Phone 344-3766 of Lending [nstitutio,: First National Bank of Anchorage ~(ailing Address: P.o. Box 720 Phone 279-4481 ~ame of Realtor or Agent: Kathy Clark. Selective Realty flailing Address: 1515 E. Tudor Road Phone 279-8624 Legal Description: .I~t 1, Blk. 1, Wi'ldwood S/D Location: 2902 Strawberry Road, Anchorage, Ak. 99502 Bdrms. 4 o Type of Facility to be inspected: Single' No. Water Supply Type of Supply: Public Utility x Individual If Individual, number of dwellings presently served If Individual, deoth of ~ell Sewage Disposal'System Type o-F S~stem: Public Utility If Individual, date of installation Individual (on-site) x