HomeMy WebLinkAboutWILLIAMSON #2 BLK 2 LT 32William on lock 2 Lot 32 ! 5- 074 -22 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP241292 PID Number: 015-074-22 Dwelling: W Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New © Upgrade Name Derek & Elizabeth Collins A ORPTION FIELD Existing ❑ D Trench ❑ Wide Trench ❑ Bed El Mound Site Address 5030 E 98Th Ave. Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 /SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original de Gravel depth beneath pipe Ft. Subdivision Block Lot Williamson #2 2 32 Fill added above original grade Gr I length Ft. Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Dist a between lines Ft. SEPARATION DISTANCES To: Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. betweenches From Tank Field Tank Line Ftz Well 100+ 25+ TANK ❑ Septic [Z S.T.E.P. ❑ Holding ❑ Other Manufacturer Greer Capacity 1500 Gal. Surface Water 100+ Material Plastic Number of compartments 2 Lot Line 10+ NA Foundation 10+ LIFT STATION Manufacturer Greer Capacity 1500 Gal_ Remarks Alarm location Electrical installed by PIPE MATERIAL House to tank Tank to D3034 drainfield Installer JR'S Drainfield CO/MT Inspector Arcterra Consulting BENCH MARK (Assumed elevation) 100 ft Inspection 1 Location and description dates: 10/18/24 2nd _10/21/24 3rd 4th �J Base of mandoor. ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp . ••e�aaas�� E O ,4+f Conditional Approval: Date IV * 493h — _ i r Septic Syste ��" Date KENNETHL4' DS 4,i �j��,Jl CE 71 6� Approved A c •• •+�h�s'\�* ote: this approval does not include well permit requirem nts ••• aaa�� (Rev 05/02/,Y8) AS—BUILT SYSTEM DETAILS/SITE PLAN Permit ❑SP241292 WILIAMS❑N #2 BLOCK 2 LOT 32 PID# 015-074-22 IU• "UrT ' 1Y,9� ESMT HE'D AC F D/W ypR • 0 r N n EXISTING K 4—BR HOUSE Isk / NEW 1500 [ STEP TANK A—C=13.5' 99.06 99.2 B—C=54.9' A—D=14.5' $ W W W B—D=55.1' g g A—E=17.1' N B—E=55.9' 4 A—F=20.9'13 B—F=57.1' a A J DJSlLATM a C3 w ]500 GAL STEP 94.92 TANK 95 u I SCALE, NTS F Ll in OF ALS •'s� PREPARED FOR: DEREK & ELIZABETH COLLINS Q, 5030 E 98TH AVE * :4 TH ANCHORAGE, AK r -► a FIELD BOOKS COMPUTED: KENNETH D S oCE-7116 BOUNDARY: N A DRAWN. KSQ w ru 're/ r/��$ . STMNG: N A CHECKED: KMD a` i/ AseuILT: JLS DATE, 10 21 2 m ,1''ESS10�� E DWG FILE: GRID: SW2437 ACAD FILE' FILE 10B N°` 24148 SCALEi 1' = 30' SCALE: NTS MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241292 Work Type: SepticTank Upgrade Tax Code Number: 01507422000 Site Legal Address: WILLIAMSON#2 BLK 2 LT 32 G:2437 Site Mailing Address: 5030 E 98TH AVE, Anchorage Owner: COLLINS DEREK B & ELIZABETH D Design Engineer: ARC TERRA CONSULTING INC This permit is for the construction of: ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: Lot Size in Sq Ft Total Bedrooms: 9/9/2024 9/9/2025 11615 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received -By: -t-a 44CT_crrrA Date: Issued By: Date: IM, ILI MUNICIPALITY OF Development Services Department On -Site Water & Wastewater Section Parcel I.D. 015-074-22 ON-SITE SEPTIC/WELL PERMIT APPLICATION Property owner(s) Derek & Elizabeth Collins Day phone Mailing address 5030 E. 98th Ave, Anchorage, Ak 99507 Site address 5030 E. 98th Ave, Anchorage, Ak 99507 Legal description (Sub'd., Block & Lot) Williamson #2 Blk 2 Lot 32 Legal description (Township, Range & Section) Lot Size 11,615 Sq. Ft. Number of Bedrooms 4 Phone: 907-343-7904 Fax: 907-343-7997 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank Upgrade ® Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Dea Duffus (Signature of property owner or authorized agent) Permit/Rush Fees: -P-360 Date of Payment: Receipt Number: nn Permit No. _ �� Y 0 V q 2 - Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241292, Deb Wockenfuss, 09/09/24 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241292, Deb Wockenfuss, 09/09/24  O Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of ~.ci.anchorage.ak. us (907) 343-7904 ON-~ITE WASTEWATER DISPOSAL SYSTEM AND]OR WELL INSPECTION REPORT Permit Number: OSPI01220 PID Number: 015-074-22 N .... ~e~ Welker Wastewater System: ~ New ~ Upgrade Address: ~0~0 ~ ~s~ Zve, ~nchor~e, ZK ~07 ABSORPTION FIELD Phone: Number of Bedrooms: ~ ~ DeepTrench ~ Shallow Trench ~ Bed ~ Mound D ~her: LEGAL DESGRI PTION ~il Rating: To~l Depth from original grade: ~'7 GPDtFt~ 2'~ Ft, Block: Lot: Su~ivision: Depth ~ pipe bo~om from original grade: Gravel depth ~neath pipe: 2 32 Williamson ~2 2 [t. 0.~ To. ship: Range: ~ion: Fill added above original grade: Gravel Length: 0.1~ Ft. 4~ +/- Ft. Well: ~ New ~ Upgrade Gravel~dth: Number of line,: I Distance be~n lines: 22.4 +/- Ft. ~, ~ FL Classification (Private, A, B, C): lotal Depth: Cased to: To~l abmrption ama: Pipe Material: PUBLIC Ft. Ft. 1~8 Ft~ D3034 Driller: D~e Drilled: ~atic Water L~el: Ins~ller: Date InstallS: Ft. Mike Andemon 10/21/~10 Yield: Pump Set at: ~ Casing Height Able Ground: ~u ~.[ [~. TAN K 8E~A~IION DISTANCE8 ~ Septic ~ Holding ~ S.T.E.P. ~ Other: T~ To Septic Abmrption~ Lffi Holding >ublic/Private Manu~urer: Capac~: ..om~ Tank Field Station Tank Sewer Line EXISTING Well 100~ 100~+ 100~+ N~ 2~'+ Material: Number of Compa~men~: s,~,~t,~ ~oo'+ ~00'+ z0o'+ Na ~ ~ UFT STATION Lot Line ~+ 10~+ ~+ N~~ size: Manu~urer: EXISTING Foundation ~+ 10~+ ~+ N~ "Pump off' level at: "Pump ~' level at: in. High ~ter a~rm at: in. in. Cu~ain Drain N~ ~ ~0~+ N~ ~ Pump Make & Model Ele~rical Inmpe~ions pefiormed by: Remarks: * None known. Previons ex~ting bed had no sewer rock. ~ENOH Location and De~dption: STEP ~nk integrity verified and cleaned. New bed ~stalled Top of gas meter per des~n and maximized nseable area-- 10' to PL~ound. A~,mod Et~,tio,: 100 Ft. P~vate well located across stree~ All other properties served by public water. Engineer's Stamp Development 8e~ices O~pa~m~t Appr0~--- Reviewed and approved by: ~9.~/~;~. ~~ate:~ - /7- AS-]SUILT SYSTEM DETAILS/SITE PLAN PerMi~ osmoiaao WlLLIAMSON ff~3 BLOCK a, LOT 3a PID~ 015-074-aa / i ~ ~ / ~ ~ N 78'~,~ , o ~ SCALE~ 1' = 40' ~A-C=835', ~-c=~,o~ ~ ~ ~15oo 6A~ ~ / STEP ~ ~ / TaNK ~ SEWER ROCK ~ 2' MOA SAND I ' ~". KEVIN ~ELKER ~ flE~ BOOKS ~: . ~: BOUNDARY ~: BMW ~S ~: ~*~ 01 ~21 ~2011 / 10-124 ' AK. 99577-~ Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System OSP101220 01507422000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: October 07, 2010 to October 07, 2011 Design Engineer: ARC TERRA CONSULTING INC Subdivision: WILLIAMSON #2 Permit Site LegalAddress: WILLIAMSON #2 BLK 2 LT 32 G:2437 Owner/Address: WELKER KEVIN P & LEANN R LIVING TRUST 5030 E 9$TH AVE ANCHORAGE AK 995070000 Site Mailing Address: 5030 E 98TH AVE, Anchorage Lot Size in Sq Ft: 11615 Total Bedrooms: 4 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ,~~~ Date:/~/'~//O Date: Municipality of Anchorage Development Services Department Buildin§ Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www. muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Property owner(s) Kevin & LeAnn Welker Living trust Mailing address 5030 E 98th Ave., Anchorage, AK Site address 5030 E 98th Ave., Anchorage, AK Legal description (Sub'd., Block & Lot) Williamson #2 Lot 32, Block 2 Legal description (Township, Range & Section) Lot Size 11615 Day phone Zip Code 99507 Zip Code 99507 Sq. Ft. Number of Bedrooms 4 THIS APPLICATION IS FOR ([~;~] all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. ArcTerra Consulitng, Inc. (Signature of property owner or authorized agent) Permit/Rush Fees: $530.00 Date of Payment: C~/~.~ ~//ID Receipt Number: {.) ~"'~""~ I ~_. (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: September 28, 2010 CONSULTING~ INC 212 E. 51st Ave, Anchorage, AK. 99503 Office (907) 868-3791, Fax (907) 868-3793 Deb Wockenfuss Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Williamson #2, Block 2, Lot 32 - Septic Upgrade Per previous discussions with you, a testhole was performed on September 21, 2009 to investigate groundwater. The results of this test are attached for your review. The owner has requested we proceed forward to obtain a septic permit to upgrade the failed leachfield on the subject lot. Due to the fact that this is the only location for the absorption field, this upgrade design will constructed per the previously permitted design SW930424. The existing sewer rock, sand filter, and any contaminated soil will be excavated and disposed off-site per code. The general slope of this lot is from east to west at a grade of approximately 0-5 %. With the exception of one lot across the street, the property and adjacent lots are served by public water. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 868-3792/FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. /-7 Kenneth M. ~S, P.E. Attachments: On-Site Sewer Application Wastewater Absorption System Plan - MOA Record Copies Soils Log / Groundwater Monitoring Owner/Contractor Specs 20441 PTARMIGAN BLVD · EAGLE RIVER, AK 99577-8736 ° PH (907) 868-3791 · FAX (907) 868-3793 WASTEWATER WlLLIAMSBN AC D/w DISPOSAL SYSTEM 02 BLOCK 2, LOT '~/'/6' 10' UTILITy gSMT 10.O' DETAILS 32 z ,o LOT 32 BLK 2 INSTALL NEW 1500 GAL STEP & DECOMISSION EXISTING TANK PER CODE E.× ~-g~ ~':' EXISTING 4-BR HouSE USE MOA APPROVED FILTER SAND MaJ~F,a~,d aa'J enNG- PRESSURIZED DISTRIBUTION SYSTEM HOLE SPACING DESIGN 1, RESIDUAL HEAD = 5' 8. HOLE SIZE = 3/16' = 1,00 GAL, PER HOLE 3, 30 GALS (PUMP DELIVERY)/1.00 GALS,/HOLE = 30 HOLES 4, 138 LF LATERAL/30 HOLES = 4,6' SPACING PER HOLE 5, ALL HOLES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS, PREPARED FOR: KEVIN VELKER 5030 E 98TH AVE. ANCHORAGE, AK 99507 FIELD BOOKS CO~PU'IED: BOUNDARY: BOUNDARY DRAW: BMW STN~INm STAKING CH£C~D: KMD A..~ILT: JLS O^~ 10/05/10 OWe. F~Le ~D: 2437 ^C~D F~Le FILE ~e .o.: 10-124- StoLe: 1'= 20' PAGE 1 OF 1 Performed for: ,~,v'...- ~--...~ ,~ A cTE A 212 E. 51~t ~ Office (907) 868-3791, Fax (907) 868-3793 ~--~~f*u, : .~ SOILS Zevin Welker mt~ ~o~m~a: ' ~~ Project: Depth Williamson #2~ Block 2~ Lot 32 ORG/OL TEST HOLE # TH 10-1 SEE ATTACHED SITE PLAN FOR HOLE LOCATION GW Was Ground water encountered? NO What depth? NA Depth to water after monitoring? DRY Date? 09/28/10 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20- SM/gm B.O.H. Ground water monitoring requested per MOA Perc rate < 1 min /" per MOA records Reading Date Gross Net Depth to Net Time Time Water Drop 1 2 3 4 5 6 7 8 9 i0 11 12 * Water Added Percolation Rate NA (min/in) Perc Hole Diameter Test Run Between feet and feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. Municipality of Anchorage Page i of 3 DEPARTMENT OF HFALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW930424 PID Number: 01507422 Name:Wastewater System: [] New ~ Upgrade Lawrence Hirai Address: 5830 E.98th Ave. Anch. Ak. 99516 ABSORPTION FIELD Phone: I NO of ~346-2590I 8~d~r°°ms: ffJ Deep Trench [] Shallow Trench ~ Bed ~ Mound LI Other Total Depth from original grade: LEGAL DESCRIPTION s°' R~""g:°. 7 GPD/Sq Ft. 2,5' Lot: Block: Subdivision: Deplh lo pipe bottom from origin¢l grade: Gravel depth beneath pipe 32 2 Williamson #2 0.0' Ft 0.5' Fb I ownship: /Range: I Secbon: Fill added above original grade: Gravel lengtb: I 4,0' Ft. 46' Ft. WELL: N/A [] New [] Upgrade Gravelwidth: Numbero(bnes: Distance between lines: 25 ' Ft. 5 i 5 f Ft. Classification (Private, A.~3,C): Total Depth: Cased To: Total absorption area: Pipe material: Ft Ft 955 SQ. Ft. 1 1/4" sch 40 ~DVC Driller: Date Drilled: SlaticWatertevel: 'nsta',~_J_tters excavatinc Datein~]ll-e~9--93 Ft SEPARATION DISTANCES [] Septic [] Holding tq S.T.E.P. Material: Number of Compadments: wen N/A 150 ' 120 ' N/A N/A Surface Water N/A 200+' 200+' N/A N/A LIFT STATION Lot Size in gallons: Manufacture¢: "Pump on" level al:I "Pum"Pump off" level al:I High water alarm at: Foundation N/A 10 ' 14 ' N/A N/A 42" MOA 46" Curtail] Pump Make & Model I Electrical Inspections performed by: Drain N/A N/A N/A N/A N/A 20 O~I HHI BENCH MARl( Remarks: Due to confined work area ~ Location and Description: a~~%th l~n¢ wa~_~d !3' long to South corner of rear door near SE corner utilize all possible area. Careful measure of house. Assumed Elevation: was taken to insure 10' minimum from 100.0' f!, foundation and property line was maintained. Inspections performed by: Theodore A. Johnson Dates: 1st. 11-12-93 Department of Health~__~ _ -~and Human Services approval 72 013 {Rev 9/91) MOA 25 0 0 / o 'T A L A SK .~ E N G I N E E R S July 6, 1994 P.O. BOX 111790 ANCHORAGE AK 99511 1790 TEL 907 349 1003 INAK 800 478-1003 FAX 907 344-9936 Municipality of Anchorage DepaEtmcnt of Health and ltuman Sm~,ices Environmental Service Division P.O. Box 196650 Anchorage, AK 99519-6650 Reference: Lot 32, Block 2, Williamson #2 To Whom It May Concern: Submitted herewith are the as-builts for refcrcnced project. The reason for the delay bctween the second inspection and submittal of this as-built was to insure satisfactory performance of the system before signing off by us. Please let us know if you have qucstions. Thank you in advancc for your assistance. Sincerely,/~,~ Theodore A. ~ohnson, P.E., L.S. TAJ/jbj Enclosurcs REGISTERED PROFEESIONAL ENGINEERS BUILDING INSPECTIONS INVESTIGATIVE ENGINEERING LITIGATION SUPPORT CONSTRUCTION MANAGEMENT MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT NUMBER:SW930424 DESIGN ENGINEER:DUMMY COMPANY OWNER NAME:HIRAI LAWRENCE D & OWNER ADDRESS:5830 E 98TH AVE ANCHORAGE, ALASKA 99516 PAGE 1 OF PERMIT DATE ISSUED:10/ll/93 EXPIRATION DATE:10/ll/94 PARCEL ID:01507422 LEGAL DESCRIPTION: WILLIAMSON #2 BLK 2 LT 32 1 LOT SIZE: 11615 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 OR 343-4681 AFTER BUSINESS HOURS 4. FROM OCTOBER 15 TO APRIL 15 A suBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: Ao OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: THE WELL ON LOT 7 BLOCK 3 WILLIAMSON #2 SUBDIVISION WILL BE ABANDONED PROPERLY PRIOR TO THE COMPLETION OF THE WASTEWATER DISPOSAL SYSTEM:THAT THIS PERMIT IS ISSUED FOR ON LOT 32: BLOCK 2 WILLIA~M~OI~ #2 SUBDIVISION. ISSUED By . ~-~----~~, ~, DATE: \%~\~\~%1L DATE: /~ -/2 - ~ ALASKA ENGINEERS P.O. BOX 111790 ANCHORAGE AK 99511-1790 TEL 907 349-1003 IN AK 800 478 1003 FAX 907 344-9936 October 6, 1993 Municipality of Anchorage Department of ltealth and Human Sel~ices On-Site Services P.O. Box 196650 Anchorage, AK 99501 Reference: Lot 32 Block 2 Williamson #2, Job No. 93393 Ladies and/or Gentlemen: Ill June of this year, we were asked to evaluate the failed septic system on the referenced property. We deterndned that the existing seepage pit and draimqeld, which was added iii 1981, have ceased to perform their designed functions. We performed a soils analysis on all adjacent site on the west side of the property and north of the existing pit. We found soils able to receive septic tank effluent at a depth of 2.1 to 5.2 feet below die surface. These soils are a coarse sandy gravel (GP). We have designed a draiiffield adequate in size to accommodate a four bedroom resideRce. We also determined the septic taak has failed and is iii need of replacement. We are mcorporatiRg a new 1,250 gallon septic tank into tlfis design. As required by AO-90-48 (S-l), Section 15.65.030.D.4. we are submitting a narrative description of probable impacts to adjacent properties. In order to accommodate die draiiffield, we would be encroaching on the 100' radius required for the private well ou Lot 7, Block 3, Williamson #2. This well is the only private well iii the subdivision. The remaining lots m die subdivision are selwed by a community well. We have made arrangements to have this well abandoned and to connect the Leach family (owners iii residence) of Lot 7, Block 3, Williamson #2 to this community system and properly abandon the private well. Adjoining lots iii the subdivision are also served by on-site wastewater systems. The upgrade of the e.-dstmg system of the referenced lot should have little if any impact on adjoining systems. Designation of a reserved space is not required with au upgrade. The existing seepage pit and dmiidield, which have failed, will be left ill place and the septic tank effiuem diverted to the new drailffield. These systems should recover and be available as reserve fields if unused. Mmficipality of Anchorage October 6, 1993, Page 2 d. Drainage of the site is generally to the north and west at approximately 2% The overall drainage of the general ama is in the stone direction at higher slopes, approximately 5%. If you have any questions about this m~rrative report or design as submittcd, please feel flee to call us for clarification. Sincerely, Theodol~ A. Johnson, P.E., L.S. Principal T^J/jbj Enclosure private well (to be abandoned Formula; 4 * 150 gpd/bdrm = 600 gpd/1.2 gpd/sf --- Proposed drainfield 2 lines, 42 feel long Standard Trench, 3' (42)x(2)x(6)=S04 sf 600 gpd 500 sf deep absorp~on /deck to be removed Iii septic tank. 'foiled ~o~ve ~iled trench Scale 1"=¥0' oreo Rev. Oct. 11, 1995 monitor tubes (2) cteanouts (8) 2" blueboard on gravel over septic, field & lines. earth fill J (2) 12" I minimum diverter valve I 12'-' I /z~+ graded gravel 1250 gallon septic tank minimum NOT TO SCALE Rev. Oct 11. 1995 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST SEAL) LEGAL DESCRIPTION: /.~, ~'Z /~'~' ¢,~ o" Township, Range, Section: 1 2 3 4 5 6 7 8 9 10 11 12 13 14. 15- 16- 17- 18- 19- 20- COMMENTS SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, ATWHAT /,',¢'4'._ ~oniloring? x/ SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop · / ~.~.,~ i/,.~-~ /~ ~,~ ~'~,' ~,, , ~,?~,, ,/~', ~ ~?~1~/~'~ /o/o~,~,~~'~" ~'~ /7;/'~ f~ ~,'~ ~ ' ~" ~- ~ {m,nutes/,nch)~ERC HOLE DIAMETER ~ /v PERCOLATION RA~ ~.Z ~ TEST RUNBETWEEN~_FTAND. ~',~FT PERFORMED BY: I ACCORDANCE WITH ALL STATE AND MUN C PAL GU DEL NES IN EFFECT ON THIS DATE. 72-008 (Rev. 4/85) CERTIFY THAT THiS TEST WAS PERFORMED IN DATE: Municipality o! Anchorage DEPARTMFNT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99802-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR:. DATE PERFORM, LEGAL DESCRIPTION: 1 6 7 8 9 10- 11 13 14 15 16 17 18, 19- 20- COMMENTS Township, Range, Section: SLOPI: SITE PLAN WAS GROUND WATER /~__ ENCOUNTERED? IP YES, AT WHAT I~ DEPTH? ----,- 0 P E Depth to W~lor Alier ~o~lLorlng?"~" ~ Date: ..~.~-/,~'"~'~ Reading Date Gross Net Depth to Nat Time Time Water Drop.,, PERCOLATION RATE ~ ~'~ (minutes/inch) PERO HOLE DIAMETER PERFORMED BY; I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 LEGAL DESCRIPTION: C~ '~2,, ~'1 ~ ')~ I~SO~ Township, Range, Section: 4- 5- 6- 7- 8- 9- 11 13- 14- 15- 16- 17~ 18- 19- 20- SLOPE BITE PLAN WAS GROUND WATER ENCOUNTERED;' S DEPTH? Oep,h to Water Aller Date. Reading Date Gross Net Depth to Net Time Time Water Drop / PERFORMED BY: . ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. 72-008 (Rev. 4/85) PERCOLATION RATE ~' / (minutes/inchl Pt"RC HOLE DIAMETFR ~-~ RUN TEST BETWEEN __ - FT AND -'-T-'- FT Formula: 4 * 150 gpd/bdrm = 600 gpd 600 GPD/O 7 Ools/SF/Doy = 857 SF Proposed drain field / / Seep(,ge Bed w/' Sand Filler, 20' , Not [o Rev, Oct 15, 1995 3/4+ g gravel 500 gallon Orenco lift station Note: station cnonhole ,?ntrohce F-monitor h~be I aa- fabric earth fill 2.5'~'-- 5' I-- 5'---4 2 5' / ~-cleon, c)urse, uniformly graded send. field system designed in accordance with EPA Design manual figure 7-28. Piping size 1 1/4" hole size 1/4" hole spaong 3' MUNICIPALITY OF ANCHORAGE MEMORANDUM DATE: October 18, 1993 TO: Accounting & Budget, DHHS FROM: On-site Services, DHHS Subject: Request for Refund(s) Please make th~ necessary arrangements for the following refund. After rewLewing the permit for on-site'w~stewater disposal upgrade it was found that the waiver application was not required. The lot had room for the required ~etback distances. The waiver has not been reviewed or processed. Receipt # 24913 and 24912 Amount $590.00 ~ccount tt 2570-9426 Lawrence D. Hirai 5030 East 98th. Avenue Anchorage, Alaska 99516 Lot 32 Block 2 Williamson Subdivision #2 Thank You. Laura J. Montgomery On-site Serw[ces Program cc: File Customer Services Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES I=nvironmental Services Division Telephone: 343-4744 ON-SITE SERVICES FEE DOCUMENTATION ~e of Payer: (Name on ,Chec?) Mailing Address: (Off of check) OS- 2491 Permit Number: Type of Payment: Cndicate Amount Paid) Health Authority: __ % 'Sewer & Well Permit: Well Permit: Sewer Permit: --. - Excavator Permit: Engineer Permit: - Pumper Permit: Well Driller Permit:. WAIVERS: Lot Line: Well to Tank: Well to Field -- . Field to Surface Copy Request: Tank Manufacturer; __. . Tank to Surface Water~ _~. ~-~-t, (Waste Treatment) 72-034 (Rev. 10/87) DISTRIBUTION: WHITE--MASTER FILE .......................... CANARY--PROGRAM FILE Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES Environmental Services Division Telephone: 343-4744 ON-SITE SERVICES FEE DOCUMENTATION OS- 24912 Date Paid: ?~/'~, --¢',~ N~rj3e of Payer: (Name on Che¢ck) Mailing Address: (Off of check) Legal Description(s): ~ Permit Number: Receipt #:. ~'~ ~-/ _Check .: ~~~~ Type of Payment: (Indicate Amount Paid) (- Health Authority: "-'Sewer & Well Permit: Well Permit: Sewer Permit: Copy Request: 72-034 {Rev. 10/87) Excavator Permit: _ Engineer Permit: Pumper Permit: Well Driller Permit: _ Tank Manufacturer: (Waste Treatment) DISTRIBUTION: WAIVERS: Lot Line: Well to Tank: Well to Field ... /~d~ Field to Surface Water Tank to Surface Water WHITE--MASTER FILE CANARY--PROGRAM FILE MUNICIPALITY OF ANCHORAGE Departmen5 of Health and Human Services On-~lte Serw[ces Section Waiver Review Worksheet WR= WR930041 PID~ 015-074-22 HA~ Perm].t = Date Received: July 15, 1993 Legal Description: Lot 32 Block 2 Williamson #2 EngJ. neer: Ted Johnson, P.E. Criterium Alaska Engineers PO Box 111790, Anchorage, Alaska 99511-1790 Applicant: Lawrence D./Deborah A. Hiral Waiver Requested: Private well located on Lot 7 Block 3 Williamson ~2 to the leachfield on Lot 32 Block 2 Williamson #2 (proposed upgrade). 84.0 feet. Criteria: 1. Geology: Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizcntal Separation TOTAL: 2. Special Conditions: 3. O~her: Waiver is Granted: List Conditions or Reasons Waiver for above: is NOT Granted: Date: By: Name of Reviewer Rec ~: 24912/24913 Amount: S 590.00 Date Paid: 7-16-93 A L A K A E N G I N E E S P.O. BOX 111790 ANCHORAGE AK 9951 t-1790 TEL 907 349-1003 IN AK 800 478-1003 FAX 907 344-9936 July 16, 1993 MUNICIPALITY OF ANCHORAGE ENVIRONMENTAL SERVICES DIVISION Mudicipality of Auchorage Department of Health & Human Services P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Separation Waiver, L32, B2, Willimnson #2, CAE Job No. 93393 Application is hereby made for the grmiting of a separation distance waiver according to Anchorage Municipal Code, Chapter 15.65.140. 1. Description of separation distances for which waiver is requested. A separation distance waiver of 84..0' from the proposed on-site draimqeld for L32, B2 Williamson #2 to a private well located in rile NE portion of LT, B3, Williamson #2. The waiver is requested as the only reasonable way to serve the existing unit and stay 10' away from the existing failed system. RECEIVED 2. Information on soils and topography. The ground around the proposed site gently slopes upward to the west at about 1% gradient toward the neighboring private well. To the east of the house it slopes upw,'u:d at a 5% slope. The ground to the nm'th proceeds level for about 50', then slopes dowuward at a 3% slope. No bedrock was found in either of the recent or previous test holes dug ou site. The soils data collected fi'om test hole information extending downward consists of about 1 ,l' layer of lomn underlain by a 3.5' clemz gravelly sand (GW) layer. Beneath tlds frmn 7.6' to 9.,6' lies a silty sandy gravel (GM/SM) layer. Beneath this lies 1.4 of sandy silt (SM) and the final 3' to the bottmn of the 14' T.H. was found to be gravelly silt (GM) material. (See enclosed soil log.) 3. Well by well log information. There is no fldly recorded well log for the well on Lot 7, Block 3, Williamson #2. There is record of its extension (included) from 200 to 240 feet, with a cased depfl~ of 238'. This will place thc bottom of rile proposed adsorption field 232' from rile cased depth of the well in question. In an atteznpt to provide geologic izfformation on the area, rile well logs from three surrounding wells have been provided. A map is presented identifying the locations of the wells. Please note that the closest well Municipality of Anchorage July 16, 1993, Page 2 log for Lot 3, Block 2, Williamson ~vas located in the on-site services file under Lot 7, Block 3, Williamson//2. If we can be of any further assistance in providing further i~fformation to support this waiver, please do not CE5191 . ',.. T~ 2~ 50 81 50G I E. 98 AVE. private well 7 ~ I° LOT ~L,k :3 Formula: 4 * 150 gpd/bdrm 600 gpd 600 gpd/1.2 gpd/sf = 500 sf Proposed shallow drainfield: 2 lines 12'& 4.6' long 5' wide * deep .5' 58' [oral length --500 si: adsorption areo.~ ~o~ ?~ Bz~- 2. deck Lo be removed :ailed oiled 1250 gallon~?t septic tank. valve trench Scale 1"=40' ?~' 27 -- uu~---c c co(,- ~"gq-?5- ItECEIVEI) ~c JUL-1L~-199~ 09:43 FROM AK-DNR/DOW 90? 896-00?0 TO 3dd9936 P.04 WELL. OWNER: LOCATION: Co~uni ty/area__\~ Rt<-DNR/DOtd 90? 090-00?0 TO [S449930 · WELTS ADL/LAS' DESCRIPTION AND CONSTRUCTION P. 02 , now ~ ~ ~,~ ~:~. as of mo_.~_ yr..~.q ..... N E ¼ ¼ ~ ¼ Sec T S R W B&M Subdivision: _k~k~lk,~,~:~ ~,~ ~ Lot ~ Block ~ ALT/LSD DATE OF VISIT:_ ~ DRILLER/COMPANY: DATE COMPLETED: WELl. FINISH; WELL DEPTH ft TOTAL CASING WATER USE INFORMATION: WELL YIELD gpm for determining discharge: WATER LEVEL: describe MP__T©C~ Measuring Instrument used:.x..ke Time 2. ft DIAMETER in. PUMP DEPTH SE-[ ft hours with ft drawdown. which is ~q Hold-cut WL below MP WL below LSD Method of below PHOTOGRAPH OR SKETCH COMMENTS; (include well yield and quality, u$¢ of ¥z¢11~ pres~n¢~ of ~ewer problem~ armd neighbors' water ~ ~, ~.4 ~, ¢ ..... , ...... // 3449936 F',08 ANOHORAG~ ALASKA f~$1O PHON~; ~07> B ?~ UNIVERSi~ AVENUE, BASEMENT * P.O. Box 772116 Eagle River, Alaska 99577 Phone: (907) 688-3555 W~ATER-LEVEL. ,D, ATA_._F. OR~M Well Local Number~ Well ~.er .. Date of Field V~sl Static Wirer Level ' ' feet beto~,~' £.~!'.~...~ (l~asuring point) . .~ZO~ F ~ ~., / ,. ~'" ¥~ /."~; ~... .. .... · Tape use~¢ .~ ~!,... Neasurer's ------m------ ~T~w lana surface Remarks (sketch 'location, additional water-level data, owner's remarks) AK-DNR/DOW 907 896-0078 1~:42 .YUL-13-1993 13:43 FROI,1 AK-DNR?DOW 90? 696-E~078 TO 3449936 P.ii 3449936 P.12 3UL-13-1993 1J:44 FROM AK-DNR×DOW 90? 696-00?8 TO SITE ID ~449~6 P,05 BILl SHEFFIELD, GOVERNOR C~ 1'9~ IJNIvE,q~IT~ AVENUE, FAIRBANKS. AE~,$KA * P,O. Box ?72115 Eagle River, Alaska Phone: (907) 688-3555 Well Local Well O~ner Date of Field Visit WATER-LEVEL DATA FORM Number '" - .,". ...... Static W~ter · 0 feet k^~ · :' ~ . ..... :_ (measurin~ point) Tape Used '' ..-' -,, ' u": '- MeasuPer~s Name '.] .... Neasuring Point is ~ '~ a~p_~Q , ~ feet~l_~,,ano surface Remarks (sketch location, additional water-level data, owner's remarks) ~,) Lu,_v.~ ! . JLL-13-199o 13:38 FROH AI<-DNR/DOW ~07 69S-007~ TO 544~36 P.O~ ~,f>' .,.: WATEH WEbL DRIIJ~RS LO<] DO' NOT PILL IN Driller ~,~~ . ~ ' ....... Size of ~sin~ __~ /' .Depth of Hol~f./~.~.~eet, C~med to Static water level~ ~,~ feet (above)(b~3) land surface, Finish of well (check one) Open end (~; Sereen( ); Perforated ( ). D~s~ri.b~ screen or perforations '~?~ ~ ~et eF drawdown from static level. Re~rks ..... hours with V~LL LOG Give details of formations penetrated, h~rdness. size of materi~l~ color, and to %o ~o to to te to L. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTN & ENVIRONMENI'AL PRDTECTION ENVIRONMENTAL ENGINEERING DIVISION 829 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITF SEWAGE DISPOSAl. SYSTEM AND/OR WELL INSPECTION REPORT MAILING ADDRESS I~ON ~-------~T~ NEW LEGAL DESCRIPTION LOCATION DISTANCE TO: J Manufacturer Liq, capacity ill gallons IF HOMEMADE: -1 Inside length Dwelling DISTANCE TO: No. of lines j Top of tile to finish grade Width NO. OF DROOMS DISTANCE T( Dwelling PERMIT NO, MQteriat No, of compartments Widt~ Liquid depth F ° u n d a t i ° nl~-. ,/,~/~., n~/ Trench Material beneath tile Crib diameter Crib depth Building foundation CJass Depth Driller Total effective absorptiol PERMIT NQ, in gallons DISTANCE TO: Building foundation Sewer line Nearest lot line Distance to lot line PERMIT NO, Septic tank Absorption area(s) OTHER PIPE MA EF{I ,A_L.~S SOIL TEST RATING INSTALLER REMARKS ~ PiOVED DATE LEGAL I IFF'LZ ..;'"fiq r LOC:WF I ON .' EEiFIL LENTF'ER,.."LFIR~?T' E:LFIF[:f( JH ..~ ,.., 1 FI L. OT ...,.[,-.L ;::' ;q..3 :::u;' SQI_IFIF.!E F'EET i'tl.-':I::<TMIJPt NI..tMBE:R OF E,E.E.,~.COM_, = ~ ,OIL R. RTZi".,I~ ~' FT,.E,E.. :IRR THE RE.:..' ]:F'EE, :,I,r_E OF THE .:.LI:[L. RE:SOF:PTZON "T"6" ':r,. ..,~ _,'f E,i'I "FHE LENGTH DIMEN:SION IS THE LENf3"FH (IN FEET::, OF THE TRENCH OR DRRINFIELD. THE [:,EPTF'I OF FI TI;.:ENCH OR PIT IS 'THE [:,I':;TFINCE BETHEEN THE SIJRFRCE OF THE GROUND FIND THE BOTTOrl OF THE E:~.,;OFIS,'ATION (IN FEET). THERE IS NO '.~ET HIDTFI FOR TRENCHES. THE ORFIVEL DEPTN IS THE: MINIP1UM DEPTH OF GRR',,,'EL BETHEEI'.~ THE OU'TI::'RI_L PIPE RND TNE BOTTOi't OF THE E:2~CFIYFI'['ION (IN FEET). PEF. ff,'IIT RPF'LICRNT HFIS THE RESF'ONSIBILITY TO INFORM "rNI:5 [:,LEF'FIRTPIENT DtJRIN(~ THE :I:NSTFILLR'rION INSPECTIONS OF FIi'.,IY HELLS RDJRCENT 'TO THIS PIROF'EF~TY FIND T[-IE NUi'tDER OF RESIDENCE'..'~ THFII" THE 1.41E:LL HIt_L SERYE. BFI-'I<:FZLLZNt~" L.. "OF Rr.,l'.r' '---,'.'~"...,_ [Ei'l. HITHOIJ'I" FI i'.,IRL ZI~4_,FE._.T'[CN'='.... FINE:.., H[-FRL.I'" ' ,'-' ""HII._ }3Y 'Fiji.=,- ' '- E:,EF'FIF.:'I"MENT I,.I]'L.L E~E SLIBJ'ECT TO FR::I..,EL. UTZ~N.''Ic'- . r'IZNIMUM DISTRi'..ICE BETHEEN F:I WELL Ri,ID Ri'-,IY ON-SITE SEI4F:IGE DISPOSFIL S'T'STEP'I IS ':l. tZIO FEET FOR FI PRIYFI'r'E NELL OR t50 1"0 ;700 FEET FROM R F'UE:I..IC HELL DEF'END]:NC.; UPON 'T'HE TYPE OF PUBLIC HELL MINIt,IUi't [:,I:3TF:Ii'.,ICE FROi',I FI PRI',/R'TE HELL TO FI PRI',,;FIT[:' SEI.4ER LINE IS 25 F:'EET RN[:, TO F'I COi'fli'tUNITY E;EE!.4ER LINE IS 75 FEET. OTHER REQUZRENENTS MRY RPPL. Y. S[:'ECIFTCRTZONS RND CONSTRUCT]CON D:[FIEiRRMS RRE FIVR1LRBLE TO ZNSt. IRE PROPER 'rNS"['RLLRTION. I CERTIFY THRT t: t FIN FRMILIFIR WITN THE REQLIIREEMENTS FOR ON-SITE SEWERS RN[.', HE:LLS RS SET FORTH E:"r' TNE NLINICIPFILITY OF RNC:HOF.'.FIGE. 2: I HILL INSTFILL THE SYSTE:M IN F:ICC:ORDRNCE I.,.t:['¥H THE CODES. 3:: I Ui",IDERSTRI'.,ID THRT THE ON-SITE SEI,.IER SYS'I"Ei','I i',IFI'T' RE:QUIRE: Ei'.,ILRF'.GFMENT IF' THE RESIDENCE IS; RENODELE[:, TO INCLUDE MORE THRN ~: BE[:,ROOi',IS. CONSTR JCTION TEST L_AB JACK WHITE COMPANY' PERFORMED FORi LEGAL DESCRIP'rlON: Let, 32 Block TI-IlS FORM REI~ORTS: El Visual Soils Ex¢~minofion 2 180( W. 48TH AVE. STE. 'C' ANCHORAGE, ALASKA 9950:5 248-1333 Subdivision DATE PERFORMED: 3/9/81 Willfson Addit±on ~2 X~ Percolation Te~t DEPTH SOIL FEET DESCRIFTION NOTES 1 ' Organics w' v, 3' SILT ~//~/~ Brown Perc Zone~ ~ .'0,, 0 7.5 ' SANDY GRAVEL - ~ Di Brown SANDY SILT .f~z Gre~ BOTTOM OF HOLE ,WAS GROLIND WKrER ,ENCOLINTERED IF YES~ WHAT DI-'PTH LEGEND ~ -- Parc zone ®S- Sample taken · -- Frozen zone ·-- Water table No Kinney R~. Baxter 3656-E I I I I I I I I I I I I I I I Nil I I I I I I ~ENERAL $1T£ SLOPE READIN4~ DATE GROSS TIME NET TIME DEPTH TO HzO NET DRAINAGE 1 3/9/81 0 2-5/8. 2 " 5 min. 5 min. 7-3/16" 5 3/16" 3 " 0 1-7/16" 4 " 5 min. 5 min. 5-3~6" 3 3/4" 5 0 2-1/2" 6 5 min. 5 min. 5-1/4" 2 3/4" PERCOLATION RATE: 2 min./inch .DRAYAGE REQUIREMENTS: 85 sq.ft./br. PROPOSED INSTALLS'ION: ~ SEEPAGE MT ~RAIN FIELD D OTHER COMMENTS: Exlstin~ system showed d~aJ~age ~eqt~ rement~ nF 22~ aq. Ft/br. Pert Test was taken to verify visual observation of the sandy gravel observed to De approximately 100 sq/ft./br. Saturation time was four hours due to time of year. ~a'cer woula not remazn ±n test haler t~ere~ore, saturation was done TEST.~[RFORMEO BY: KINNEY R. BAXTER,PE DATA CERTIFIED BY:. KINNEY R. BAXTER, P.E. several times in this time. DATE: 3/10/81 TER ANCHORAGE AREA BO' UGH Department of Environmental Quality 3330 C Street Anchorage. Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME LOCATION ~)~/ ~:~'~ /-~'¢/~ '~"~/'~-'~'"'/ LEGAL DESCRIPTION SEPTIC TANK: D I S T A N/C-dE/c-,,x] FROM W-E-.A, L MANUFACTURER .~ / -/3-e I NUMBER OF _ MATERIAL ,~'~'~'E/-- COMPARTMENTS INSIDE LENGTH INSIDE WIDTH ,LIQUID DEPTH_____LIQUID CAPACITY /~ GALLONS. SEEPAGE PIT: NUMBER OF PITS / DIAMETER . OR WIDTH LENGTH__, DEPTH // · LINING MATERIAL ~/,¢~3 ~'¢~0~1B SIZE: - DIAMETERZ'~¢CDEPTH ~' DISTANCE FROM; BUILDING FOUNDATION '~,,2 / TOTAL EFFECTIVE ADDITIONAL ABSORPTION NEAREST LOT LINE ABSORPTION AF1EA (WALL AREA) 4¢:O //-' SQ. FT. WELL.: TYPE BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION NEAREST NEAREST LOT LINE SEWER LINE OTHER SOURCES DISAPPROVED__ REMARKS DEPTH DISTANCE FROM: SEPTIC SEEPAGE TANK __ SYSTEM DISTANCES: INSTALLED BY: ~?~-'~' /t//~¢~' PIPE MATERIAL: LOT SLOPE: REMARKS: · ~Lo .'~ -~',~7--- /~,.~ 2-zo DIAGRAM OF SYSTEM G,A.A.B. iNSTALLATION LOCATION O/~/~ ~ ~ ~ GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY PERMIT NO SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT TO B~ INSTALLED IBY HOTE= THi~ PERMIT I~; NOT VALID WITHOUT ~O.I[. TE~'I' FOUNDATION TO SEPTIC TANK SEPTIC TANK TO SEEPAGE Pit WALL SEPTIC TANK __ ~'~ -, SEEPAGE PIT ~--~'., gRAIN fielD TO NEAREST LOT LINe, WELL TO SEPTIC TANK , SEEPAGE PIT DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK / DRAIN FIELD ~/ /~ 1 / SEPTIC TANK, ~ ~, SEEPAGE PIT , DRAIN FIgLD TO RIVER, LAKE, STREAM. OR I CERTIFY THAT I AM FAMILIAR wI'rH THE REQUIREMENTS OF GREATER ANCHORAGE AREA ]3OROUgh ORDINANCE NO. 2~3.6B AND THAT THE ABOVE MUNICIPALITY OF ANCHORAGE �j Development Services Department / Phone: 907-343-7904 On -Site Water & Wastewater Section—' Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 015-074-22-000 Expiration Date: Legal description WILLIAMSON#2 BLK 2 LT 32 Site address 5030 E 98TH AVE Anchorage AK 99507 Current property owner(s) COLLINS DEREK B & ELIZABETH D 10/21/2025 X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: L2 Original Certificate Date: 11/7/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA ApprovaLkne 2022 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 015-074-22 Complete legal description Williamson #2 Block 2 Lot 32 Location (site address) 5030 E 98th Ave. Anchorage, AK Current property owner(s) Derek & Elizabeth Collins Day phone 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units V Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel 0 Plastic ❑ Concrete ❑ Fiberglass Age 0 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS © Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Distance: Expedited review requested: ❑ By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ 5_E5_0 Date of Payment /0 2 cf/ LZ' Y COSA# 05C2.LI 1 y3q Waiver Fee $ Date of Payment Waiver # COSA Application—June 2022 COSA Checklist Legal Description: _. _ Williamson #2 Block 2 Lot 32_ Parcel ID: 015-074-22 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system _ DATA ❑ Well logwith Onsite (or attached) Date drilled I depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in Date of flow test for COSA Static water level at beginning of test ft. Comments B. TANK DATA Measured operating fluid level in septic tank New Date of pumping ❑ Required maintenance completed, if AWWTS Comments: New install 10/18/24 D. ABSORPTION FIELD DATA Which system tested (date installed) 10/21/2010 R ALL standpipes present per record drawing Total measured depth from grade 2.65 ft (max) Measured depth to pipe invert from grade ft (min) ✓❑ N/A — pressurized field. ✓❑ Per record drawings, field is insulated. ✓❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies COSA Checklist June 2022 Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative rate mg/L ❑ Nitrate less than MRL (ND) Arsenicug/L ❑ Arsenic less than MRL (ND) Collected by Date C. LIFT STATION ✓❑ Required maintenance completed Age of lift station 0 years Lift station material Plastic Comments: Adequacy test date 8/30/24 Results 0 Pass Fluid depth prior to test 0 in Water added 600 gal New fluid depth 0 in Elapsed time 1 min Final fluid depth ' 0 in Absorption rate 600+ gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 6 in Effective depth used 0 in Effective depth remaining 6 in E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' 0 Yes if No Community Sewer Manhole/Cleanout > 100' ❑ Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No ft Neighboring Absorption Fields > 100' if No ft Animal Containment > 50' ❑ Yes if No ft ❑ Yes if No ft ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑ Yes if No ft ❑ Yes if No ft 0 N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' 0 Yes if No ft Surface Water > 100' Q Yes if No ft Tank to Property Line > 5' 7 Yes if No ft Wells on Adjacent Lots: Al Field to Property Line > 10' 0 Yes if No ft Private Wells > 100'✓❑ Yes if No ft Water Main > 10' 0 Yes if No ft Community Wells > 200' © Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Arcterra Consultin Engineer's Printed Name Kenneth Duffus Phone (907)-696-x6111 Date Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year i s and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator Al of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen ■� encroachments, deficiencies or discrepancies exist. i'n COSA Checklist June 2022 V_. CE 71 iYS f 3o.01 20' LLJ > 00 0-) LLJ ANCHORAGE RECORDING DISTRICT, ALASKA AS -BUILT OF: WILLIAMSON SUBDIVISION ADD Not LOT 32 BLOCK 2 PIAT 71-187 * = FND 5/8" REBAR SURVEY CERTIFICATE: 1, John L. Schuller, Have conducted a A4W 0 F AW physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance should ,0,0 C�) 9rI'H a •, A0 - any information on this drawing be used for construction of fences, *................ . ........ structures, improvements, or for establishing boundary lines. ?A — ? EXCLUSION NOTES: It is the owners responsibility to determine j 1 .0 ....... ........ ............... N 0 .1 OV the existence of any easements, covencants, or restrictions which '.IGH L. SCHULLER-* LS -10408 do not appear on the recorded subdivision plat. WORK ORDER NUMBER- DATE: SCALE. E—MAIL. OCT 30, 2024 1 =20 schullerakOgmail.com DRAWN BY: CHECKED BY GRID NUMBER: BOCK AGE: 0 f 24-104 k�' eSSjon& A"F JLS SW2437 240333 S Up) V �' 0 r 44 c 1.831 Talkeetna Street Anchorage, Alaska 99508 (907) 227-1455 office (907) 274-4992 fax �£ 8 • "� Municipality of Anchorage On -Site Water and Wastewater Program < (907)343-7904 SAFETY CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 015-074-22 Expiration Date: 1 Z 0 Z3 1. GENERAL INFORMATION Complete legal description Williamson #2 Block_2 Lot 32 Location (site address) 5030 E 98th Ave. Anchorage, AK Current Property owner(s) Jason Decourcey __ Day phone Mailing address 5030 E 98th Ave. Anchorage, AK Real Estate Agent 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone _ 3. NUMBER OF BEDROOMS: 4 TYPE OF WASTEWATER DISPOSAL: 4. TYPE OF WATER SUPPLY: Individual Individual Well ❑ Holding Tank ❑ Individual Water Storage ❑ Community ❑ Community Class A Well 0 Public Sewer ❑ Public Water System Waiver/Variance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 1 q 5 Date of Payment renew, Receipt Number _ 05 a R16 COSA# 05ca �? 1 OL a Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING, INC. Phone 696-6111 Address 20441 PTARMIGAN_ BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS _- Date Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future +� �� \ occupants or can ArcTerra guarantee that no unseen OF �L`� \ encroachments, deficiencies or discrepancies exist. p, 6. DSD SIGNATURE System #1 Approved for bedrooms. System.#2 Approved for bedrooms. Disapproved. �1 �` 7 '01TN . KENNETH 1 1'PUS ` AW Conditional approval for _ bedrooms, with the following stipulations: ((LLT n�v v rn JJJJ BY w� .__-__ Original Certificate Dater- �0 ZZ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA blue sheet -10-10-12 doc Nitrate Advisory Arsenic Advisory p� Other Legal Description: Williamson #2 Block 2 Lot 32 If more than 1 septic system on lot: COSA Checklist # /ELL DATA ❑ Well to�ed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments B. TANK DATA Age of tank(s) Z9 years Tank type/materia.) Septic/Steel Measured operating fluid level in septic tank 4299 Standpipes/foundation cleanout per record drawing Date of pumping 2/23/22 D. ABSORPTION FIELD DATA Which system tested (date installed)10/21/2010 ALL standpipes present per record drawing Total measured depth from grade 2.65 ft (max) Measured depth to pipe invert from grade 2.15 ft (min) ❑ N/A — pressurized field Monitor tubes go to bottom of effective. If not, state depth into effective Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet Parcel ID: 015-074-22 of Structure served by this system Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) ug/L ❑ Arsenic less than MRL (ND) Collected b Date of Sample C. LIFT STATION Required maintenance completed Age of lift station 27 years Lift station material Steel Comments: Adequacy test date 4/20/21 Results Q Pass For 4 bedrooms Fluid depth prior to test 0 in Water added 600 gal New depth 2 in Elapsed time 5 min Final fluid depth 0 in Absorption rate 600+ god Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES rivate Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Li on Lot > 100' Community Sewer Manhole/Cleanout > 100' Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' ❑ Yes I ft Private Sewer/Septic Line > 25T-1Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No ft [ding Tank > 100' ❑ Yes if No ft Neighboring Absorption Fields > 100' Animal Con r > 50' ❑ Yes if No ft ❑ Yes if No ft Manure/Animal Excreta Stora 0' Community Sewer Main > 75' ❑Yes if No ft _ ❑ Ye ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No 5'+* ft Surface Water > 100' ® Yes if No ft Property Line > 5' ® Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No ft Water Main > 10'--- - Yes if No ft Community Wel!s > 200' Yes if No ft Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No ft If absorption field'is under driveway comment below Property Lne'> 10' ® Yes if No ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No ft Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS *Meet code at time of installation. G. ENGINEER'S CERTIFICATION I certify that i have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet www.muni.org/onsite Septic Tank Advisory Certificate of On -Site Systems Approval # OSC221062 Subdivision: Williamson #2 Block:2, Lot: 32 The septic tank for this property is 29 years old. The average life for a steel septic tank is 20 years. Typical replacement costs range from $7,000 to $11,000. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 30 year old steel tank MAY look like. Mailing Address P. O Box -196650 *Anchorage, Alaska 99519:6650 *www muni org MUNICIPALITY OF A 71 Dewelcpmc-n� Sen,"I"ces Departmlum &Section ice,,.}.1. Maintenance Log Septic Tank= -Sludcie level inches- -'PUMMDin--, rCCl Lift -station: 7 basket cleaned U"Esj r n, Jmp -Effluent filt er cl e a 1) e d *Control floatt, cicained *Proper float 5-otkings Cor -Operation Alarm System: e1octnta7 alarm circuit -Au ctac- —1i I Flrd 'v7suIP-! a�arm d%velf-rc ivcsN no -Al.anm systern 0 L Ml Is Riser -C-3,701-Ind wcltre-' ilfltruslo-� al, crx-,inf-.("flc)7C s ---------- - - - *Gro,•-.,,nd wator intrusicrn aar-ound pc- p -TA'anhole lid: Furc-tional (Ves) r.f- 1!s, ulate no 0, erly Secured COT r recu.,red @ 'Ornments: QualffiLd Maintenance Provider. Cornoanv Da�e &gnatur�,, - Daze PSE 3°. Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 s E T Y CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 015-074-22 1. GENERAL INFORMATION Complete legal description Williamson #2 Block 2 Lot Location (site address) 5030 E 98th Ave. Anchorage, -AK Current Property owner(s) Mailing address Real Estate Agent ene Rosebecke Expiration Date: __.__f _ q,�og Day phone 5030 E 98th Ave. Anchorage,_AK 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 TYPE OF WASTEWATER DISPOSAL: 4. TYPE OF WATER SUPPLY: Individual Individual Well ❑ Holding Tank ❑ Individual Water Storage ❑ Community ❑ Community Class A Well Public Sewer ❑ Public Water System [] Waiver/Variance request for: Distance: Received by: _ Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 55 iJ Waiver Fee $ Date of Payment ylZ 9 Zd .2 Date of Payment _ Receipt Number 5 ` g G Receipt Number COSA# SCO, 11 a 19 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING,. INC. Phone 696-6111 Address 20441 PTARMIGAN BLVD., EAGLE_RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS . Date Yse o ..-( Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The entof the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future ® occupants or can ArcTerra guarantee that no unseen - �, OF -41 encroachments, deficiencies or discrepancies exist. AN",' 6. DSD SIGNATURE System #1 Approved for � bedrooms. KENNETH " <` System #2 Approved for bedrooms. f rsstu-S Disapproved. Conditional approval for bedrooms, with the following stipulations: v - - ON-SITE m -- J2 ` AWA FER-ANO___ _ -- =- WAS7.1VATER o PROGRA By: _ Original Certificate Date:,,__ 5 0202 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA blue sheet -10-10-12 doc Nitrate Advisory Arsenic Advisory OtherT0_ � (dv;__s�_ X Legal Description: COSA Checklist Williamson #2 Block 2 Lot 32 If more than 1 septic system on lot: COSA Checklist # DATA ❑ Well oed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Comments B. TANK DATA Age of tank(s) 28 years Tank type/material Septic/Steel Measured operating fluid level in septic tank 42" Standpipes/foundation cleanout per record drawing Date of pumping 4/29/21 D. ABSORPTION FIELD DATA Which system tested (date installed)10/21/2010 ® ALL standpipes present per record drawing Total measured depth from grade 2.65 ft (max) Measured depth to pipe invert from grade 2.15 ft (min) ❑ N/A — pressurized field �f Monitor tubes go to bottom of effective. If not, state depth into effective ® Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies. COSA Checklist yellow sheet Parcel ID: 015-074-22 of Structure served by this system Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? ❑ Yes ❑ Nc ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) ug/L ❑ Arsenic less than MRL (ND) Collected Date of Sample C. LIFT STATION FO Required maintenance completed Age of lift station 27 years Lift station material Steel Comments: Adequacy test date 4/20/21 Results p✓ Pass For 4 bedrooms Fluid depth prior to test 0 in Water added 600 gal New depth 2 in Elapsed time 5 min Final fluid depth 0 in Absorption rate 600+ gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES rivate Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Li on Lot > 100' if No 5'+* Community Sewer Manhole/Cleanout > 100' Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' ❑ Yes i ft Private Sewer/Septic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No ft Iding Tank > 100' ❑ Yes if No ft Neighboring Absorption Fields > 100' if No Animal Con > 50' ❑ Yes if No ft ❑ Yes if No ft Water Main > 10' ® Yes if No Manure/Animal Excreta Stora _ 0' Community Sewer Main > 75' ❑ Yes if No ft ❑ Ye ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No 5'+* ft Surface Water > 100' ® Yes if No ft Property Line > 5' ® Yes if No ft Wells on Adjacent Lots: ® Yes Absorption Field > 5' ® Yes if No ft Private Wells > 100' Yes if No ft Water Main > 10' ® Yes if No ft Community Wells > 200' Yes if No ft Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' 0 Yes if No ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No ft Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS *Meet code at time of installation. G. ENGINEER'S CERTIFICATION 1 certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with ¢gm MOA COSAguidelines in effect on this date. s s, CE "0 COSA Checklist yellow sheet MUNICIPALITY OF ANCHORAGE    DEVELOPMENT SERVICES DEPARTMENT    907‐343‐7904  On‐Site Water and Wastewater Section                                                                                           Fax: 343‐7997  www.muni.org/onsite         Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org      Septic Tank Advisory   Certificate of On‐Site Systems Approval # OSC211214   Subdivision:  Williamson #2  Block:2, Lot: 32  The septic tank for this property is 28 years old.  The average life for a steel septic  tank is 20 years. Typical replacement costs range from $7,000 to $11,000.   This advisory must be attached to all copies of the subject Certificate of On‐Site  Systems Approval.               This is an example of what the metal of a 30 year old steel tank MAY look like.        Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-074-22 1. GENERAL INFORMATION Complete legal description COSA # 05C_ I t Expiration Date: 2 -- // '7 -' / ~' WILLIAMSON #2, BLOCK 2, LOT 32 Location (site address) 5030 E 98TM AVENUE, ANCHORAGE, AK 99507 Current Property owner(s) KEVIN & LEANN WELKER Day phone Mailing address 5030 E 98TM AVENUE, ANCHORAGE, AK 99507 Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF 'BEDROOMS: TYpE OF WATER :~UPPLY: IndiVidual Well Individual Water Storage Community Class __ Well Public Water System 4 [] [] [] [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [~ Individual Holding Tank ["-] Community 'On-site ['-] Public Sewer r-] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certiticates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period .of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a publicwater system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein: I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. DSD SIGNATURE ~'""Approved for ~- Disapproved. Conditional approval for Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3792 Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 01/21/2011 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions .as of the day tested. The flow. and' absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local sOil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a .~~'..~ system will function satisfactory for current or future ~~. ~.~' ~'"~!! ":~'!'~/.-'::i~. '.'. occupants or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies exist. :.~ :......;...~". bedrooms. bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's RePort Other Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: W~LLIAMSON #2, BLOC/( 2, LOT 32 A. WELL DATA Well type PIYBL_IC IfA, B, or C provide PWSID # Date completed Total depth ft. Sanitary seal (Y/N) Cased to ft. FROM WELL LOG Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform colonies/100mL Nitrate Arsenic: __.mg/I Date of sample: B. SEPTIC/HOLDING TANK DATA ft, mg/L Collected by: Well Log (Y/N) Parcel ID: 015-074-22 Wires properly protected (Y/N) Casing height (above ground) in. AT INSPECTION Tank Type/Material Septic/Steel Date installed 11/19/1993 Tank size 1500 gal. Number of Compartments _2 Cleanouts (Y/N) _Y Foundation cleanout (Y/N) _Y Depression over tank (Y/N) __N High water alarm (Y/N) Y Date of pumping 10/20/2010 Pumper Around The Clock C. ABSORPTION FIELD DATA Date installed 10/21/2010 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.7 System type Bed Length ~15 ft. Width 22..~. ff. Gravel below pipe 0.5 ff. Total depth 2.65 ff. (=as=~ Depression over field Results (Pass/Fail) Pass Water added gal. New depth in. Absorption rate >= __ If yes, give date __ For ~__ bedrooms in. Eft. absorption area 1008 ft2 Monitoring tube Y Date of adequacy test NA - New System Fluid depth in absorption field before test __ in. Elapsed Time: min. Final fluid depth Any rejuvenation treatment (past 12 mo.) (YIN & type) g.p.d. D. UFT STATION Date installed 11/1~/1~)3 ~Pump on' level at 4:1 in. Datum Bottom of Tank E. SEPARATION DISTANCES Size in gallons 1500 "Pump off' level at__ Cycles tested Z__ 4O SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/liE station on lot Absorption field on lot Public sewer main Sewer/septic service line Animal containment areas in. Manhole/Access (Y/N)__Y High water alarm level at 46 in. Meets alarm & circuit requirements? Y__ On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main :10'+ Water service line :10'+ Surface water :100'+ Wells on adjacent lots * :100'+ Private &: 200'+ Public SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line :10'+ Building foundation :10'+ Water main :10'+ Water Service line :10'+ Surface water :100'+ Driveway, parking/vehicle storage. 10'+ Curtain drain 50'+ (None Known) Wells on adjacent lots * 100'+ Prvt. 200'+ Public F. COMMENTS · Lot across the street has private well, all others are on public water. G. ENGINEER'S CERTIFICATION .~\'~':~. . . ~ .~:~:~'"'.'i~.i' :-.i... ~ ".~='-- :..~...~. -.~~ .~' review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name KE]~ETH M. DUF]~S Date 01/21/2011 ...:., ..;...: ..!. :..~. .... ? ..... . COSA Fee ~ ~3.~::)"~~ Waiver Fee $ Date of Payment Receipt Number (Rev. 11/05) Date of Payment Receipt Number I ,30.0' 45.1' LOT BLK 32 2 N U TILl Ty SEPTIC -- VENT -- (TYP) ANCHORAGE RECORDING DISTRICT, ALASKA AS-BUILT OF: WILLIAMSON SUBDIVISION ADD NO2 LOT 32 BLK 2 PLAT 71-187 AC D/W SURVEY CERTIFICATE: I, John L. Schuller, Have conducted a physical survey of this property as shown on this drawing and that the improvements situated hereon are within the property lines and no enchroachments exist other than noted. Under no circumstance should any information on this drawing be used for construction offences, structures, improvements, or for establishing boundary lines. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. WORK ORDER NUMBER: NOV 10, 2010 ~ 1"=20' kndeng~k, net dLS ~ 2437 100332 w ~7.?6, LOT BLK 31 2 CO LOT BLK 33 2 SET 5/8" REBAR W/YPC FND 5/8" REBAR .... · "",' °~ / ~ehorage, Maska 99~08 (907) ~7-1455 office (907) 274-499~ fax MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division ol Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 1. GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner ,' Mailing address Day phone [.ending agency Mailing address Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: ~ TYPE OF WATER SUPPLY: NOTE: Individual well Community well ;( Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAl..: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 5. STATEMENT OF INSPECTION BY ENGINEER As certified by nly seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on~site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm $ & $ ENGINEERING lzU;~4 ~a~l~ R;-,~, ko~ .~,t,~d N=~ Phone ~ d'~ - ~ 7 ~ Address Eagle River, Alaska 99577 DHHS SIGNATURE Approved for /L-~¢ C/~ Disapproved. Conditional approval for bedrooms, bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Services (DF .S) issues Health Authority Approval Certificates based only upon the representations given in paragraph ~-; above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. RECEIVED Municipality of Anchorage JUN 2 DEPARTMENT OF HEALTH & HUMAN SERVICES Envirenmental Services Divisior e 825 L Street, Reom 502 · Anchorage, Alaska 99501 · (907) 343-474,4 Health Authority Approval Checklist LegalDesoription:~_or ~ 8~-0~-~: ~ ~.,,~.,,~.-,~o.,, ~ z_ Parcell,D.: 0I~F-°'Ty-)'?' A. WELL DATA Well type If A, B, or C, atlach ADEC letter. AE)EC water system number' LOt] present (Y/N) Total depth Sanitary seal (Y/N) Date completed Cased to FROM WELL LOG Date of test / Static water level ~ Well production ,/ WATER SAMPLE~LTS: Coliforrr / Nitrate D~ o~fsample: Casing .he.~r'~ove ground) ~VV. if~pr%perly protected (Y/N) AT INSPECTION g.p.m. Collected by: Other bacteria g.p.m. B, SEPTIC/HOLDING TANK DATA Date installed ~'1/r fl (' ~d 7 Tank size / ~-o o Number of Compartments ~ Cleaneuts (~N) Foundation cleanout I~/NI Date of Pumping ~// C, ABSORPTION FIELD DATA Date installed /~//'l/q ~ Length ~¢(~ Width _ Effective absorption area ~ -('~-/~'~ ~'' Date of adequacy test ~ (/¢~ / "t '~ Fluid depth in absorption field before test (in.); Fluid depth_ ~)~-Y (ins) Minutes later: Soil rating ~.~.~./~.~or fF/bdrm) O. 'l System type /~ Gravel thickness below pipe O. ~__ Total depth Monitoring Tube present(l~/N) Yf.~- Depression over field (Y/~'~ .t, o Results (Pass/Fail) /~A '~J For ~¢' bedrooms P*~')~ Immediately after/~°3~gal, water added (in,): rJ/4 Absorption rate = G O 8 .-' g,p.d, Peroxide treatment (past 12 months) (YIN',, /-,o,...& /¢ '"~/'" If yea, give date 72-026 (Rev. 3/96)* D, LIFT STATION Date installed Manhole/Access (~N) High water alarm level at* Cycles tested Size in gallons "Pump on" level at* *Datum "Pump off" level at* E, SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main Sow~ Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation ~ -w Propertyline 5" -/ Absorption field Water main/service line /o ~ On adjacent lots Surface water/drainage ?o e -/- Wells on adjacent lots /o Property line Surface water Curtain drain SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: I o Building foundation )Go Water main/service line Driveway, parking/vehicle storage area '3 Wells on adjacent lots ,) 0 O F. ENGINEER'S CERTIFICATION .~.,...,,,..,~.~.~,_',~,~ I cedify that I have determined thru field inspections and review of Municipal rec~lhe ~ ~ms are ~ ~ . in conformance with.M~A ~ guiEefines in effect on this date. ~ ~ ' Engl'neer s Name /~ ~/~ ~'~ ~, L0~4~ I~ ~ ~ ROBERT. C,:COWAN HAA Fee $ ~L~ ,, ,::(~ Date of Payment ~'/?-~////~"~ Receipt Number 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number ,,~:~ ~-~.,:..'..,~. _,/~.~ _ - :.~MUNiCiPALI'r~LOF~NCHO~IAGE .: --,-:~.~.: .. :t~.~-~--:. . ~: ': ~ .... .}~.~:'.;;/,'' ?... ;.~.~) 'k~],,;:.~ Divlsi0nof Eh~tr6nm~ntal So~I~eS ...... ~ ~:'r' :.-.:~-.:.-'.'(.,t - .:, ' * 4'' : ' ' ' ..... ~ CERTIFICATE OFH~LTH'AUTMORI~j'< ........... ',-- ...... : ''.2 .... -- ' ' APPROVAL FOR A SINGLE FAMILY DWELLING - , ':' ",.'.~'Parcel'l.D:~ 501507'422 ......" · .'~": ~-:..~-..--.,. :--:. r;H~ ~. ~~ " .... " . :.:,.~..~:.~1.6::~GENERAL INFORMATION ~-~%...4 ~ .~:, ', :.~:-,` .~.:: .,~-~--.. · :.:-:~.~. ~:-.~ :- ....... ~.,,,;.~ _-.:. '.% :.~ ,,: . .~;~sL~/~?~:~i}~: L~atlon'(site:ad~ress or dlrectmno):." 5830.-~ 98~ Avonuor .~choraqor AK : 99516 ~ frOm'~state ADEC ~ to the leg~htyand status Of system.: . . ~..-. /, .; ~*~.· ~ i .)~ '.'? .~.'?' As certified by my seal affixed hereto and as of the vah~lation ~l~t~ ~h~w~.'bei~w! 'l'v~rlfy ih~t nvest gat on'of th s Hea th Author ty.~,pprova"apP catio'r~' shows' th~it.the On-site Water supplY:.: . ...... ~., . -., ¢. ~..~ and/or wastewater disposal system ~s ~fe, funct onal and adequate for the number of bedrooms and Wpe of structure nd cat~ here n fu~her vet W that based on the nformat on obtain~ from the MunicipaliW of Anchorage files and from my inves~ation and inspection, the on-site water supply and/or wastewater dlspo~l system is in compliancewith all Municipal and State codes,_7~. ~,: ordinancos, and r~ulati~n~ In off~ct on tho dat~'0~ ihi~ ins~ctlon.. _. ... . · /-. ,..-.. . .' .'. Engin~ffs s,gnatu , :Date / . . ?'::~"" '?'. :._:.'/-.: '. :';L}?.- :;: ~'--'L,';?:: ' '" '"" :: ~' ' ,'-*:. ¢ Additional Comments · ...... ~1~:.{ ,~~A/~]_ _ ,-:: >_ , , ~ · : ..... Bate:¢ ' '/~},~}mhe;MUh~~ ~& ~.of Ancho'ra~e'Depanment~of Hca th and Human So.ices """,~ovai'ce~i~ ~t~s' 6as~ 0n y' UPon the representations giVen !~paragmp~ 5 'above : ~ p~ofesSional Onglh~r r~ister~ in tho ~tate of Alaska.~he DHHS does t~js as ~ c~u~es~to purchasom ~ COndUct InsPections Or'and ~e data .~efore a cellulite ,s i~'~ed~;~}~? ~',~i~ii~ ~;~h~e : ¢ .responsible for errom or om.~i~n~ I~th~ Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: L32, B2r williamson I~2 Parcel I.D. 01507422 A. Well Data Well type ~. /~¢' If A, B, or C, attach ADEC letter. ADEC water system number__ ?] Log present (Y/N) N/A __Date completed N/A Driller N/A Total depth N/A Casing height Sanitary seal (Y/N) Wires properly protected (Y/N) N/A N./A Cased to t,~./,~ FROM WELL LOG AT INSPECTION Date of test N/A N/A Static water level N/A N/A ~"1~ Well flow N,/A g.p.m. N/A g.p.m. ~'~'1 Pump level1 N/A N/A "< SEPARATION DISTANCES FROM WFLL TO: ~ Septic/holding tank on lot N/A ; On adjacent lots N/A Absorption field on lot N/A ; On adjacent lots N/A Public sewer main N,/A Public sewer manhole/cleanout N/A Sewer service line N,/A Petroleum tank N/A WATER SAMPLE RESULTS: Coliform N/A _Nitrate N/A Other bacteria N/A Date of sample: N/A Collected by: B. sr-'PTIC/HOLDING TANK DATA Date installed 11/19/93 Tank size 1250 Compartments 2 "~ Foundation cleanout (Y/N) ¥ Depression (Y/N) Alarm tested (Y/N). Cleanouts (Y/N) ¥ High water alarm (Y/N) Date of pumping Pumper Y SEPARATION DISTANCES FROM SEpTIC/HOLDING TANK TO: Well(s) on lot N/A On adjacent lots 124 ' Foundation To property line 10 ' Absorption field .55 ' Water main/service line Surface water/drainage 200+ ' ' ' ' ' 72-026 (3/93)* Front CONTINUED ON BACK PAGE C. LIFT STATION Date installed 11/19/93 Size in gallons 250 + 1250 Vent (Y/N) ¥ "Pump on" level at Manufacturer OR bl'qCO Manhole/Access (Y/N) y 42" "Pump off" Level at Cycles tested 3 High water alarm level 46. Meets MOA electrical cedes (Y/N) ¥ SEPARATION DISTANCE FROM LIFT STATION TO: Well on lot N/A On adjacent lots 124 ' D. ABSORPTION FIELD DATA Date installed 11/93 Soil rating (GPD/Ft2) 0.7 Length /~:::~' ~ Width Gravel thickness Total absorption area ~ ~"~-~' '~- Cleanout present (Y/N) Date of adequacy test N/A Results (pass/fail) Water level in absorption field before test N/A Peroxide treatment (past 12 months) (Y/N) N/A SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot N/A On adjacent lots 150' N/A 4?" Surface water 2f~O ' + System type Raised bed - Total depth _ ~-,; ~ % Depression over field (Y/N) ~ for Bedrooms After test N/A If yes, give date N/A Property line 10' To building foundation 10 ' On adjacent lots N/A Surface water N/A Curtain drain N/A To existing or abandoned system on lot 60' Cutbank N/A Water main/service line 40 ' Driveway, parking/vehicle storage area ~10I E, ENGINEER'S CERTIFICATION I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. InfformatJon ~/~bove extracted from as-built of upgrade appro~ En¢ 4 N~mo T~ore A. Johnson, P. B., L..,,~,.~ ... ~,..,~.., .. ~., ~.S. ['~ H~ Fee $ ~ ~ ' ~/~ Waiver Fee $ Date of Payment ~-/~ ~ ¢~ Date of Payment . ce pt Numb.r ¢¢'7 . o ipt Numb. 72-026 (3193)* Back TIME DATE INSPECTOR INSPECTI ON APPOINTMENTS INSPECTORINSPECTOR\- ¢r~.. (~._ $~,~. ~ t ~ MUNICIPALITY OF ANCHORAGE DEPL OF "J [ ENVIRONMENTAL SANITATION DIVISION JAN 2 5 i981 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten {10) days for processing, 1. PROPERTY OWNI:R PHONE Frank L. and Ingebor~, G. Lentfer 344-0685 MAILING ADDRESS 5030 East 98th, Anchorage, Alaska 99504 PROPERTY RESIDENT IIf different from aoove} PHONE 2. BUYER PHONE Laurence and Deborah A. Hirai 349-2949 MAILING ADDRESS SR "A", 133-J, Anchorage, Alaska 99504 3. LENDING INSTITUTION PHONL: Lomas and Nettleton 274-7661 MAILING ADDRESS 4449 Business Park Blvd. , Anchorage, Alaska 99503 4, REALTOR/AGENT Larry Clarke, Jack White Company PHONE 277-3`553 ~AILING ADDRESS 3201 "C" Street, Anchorage, Alaska 99503 LEGALDESCRIPTION Lot 32, Block 2, Williamson Subdivision, Anchorage Recording District STREET LOCATION 5030 East 98th, Anchorage 6. TYPE OF RESIDENCE NUMBER OF,SEDROOMS [] One L~ Four ~ SINGLE FAMII-Y [] ~LTwo [] Five ~ MULTIPLE FAMILY ~'~,~'~Th r ee [] Six [] Other 7. WATER SUPPLY [] INDIVIDUAL~ ~ ATTACH WELL LOG. A well ~og is required for all wells drilled [] CC VIMUNITY since June 1975. For wells drilled arior to that date, give well [] PUBLIC UTI LITY oepth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM E~ INDIVIDUAL;ON-SITE** 3_973 YEAR ON-51TE SYSTFM WAS INSTALLED. [] PUBLIC UTI LITY NOTE:: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72 010 (Rev. 6/79) THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS '[] SINGLE FAMILY [] ONE '[] THREE [] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVI DUAL DEPTH OF WELL '[~ COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER 'E~ INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER 'E~]SepticTank or []Holding Tank Size: ~C'~'~'~ If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA MATERIAL 4, DISTANCES WELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line Absorption Area to nearest Lot Line 5. COMMENTS ~ APPROVED FOR _<~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [] DISAPPROVED 72-010 (Rev. 6/79) Municipa ityo 825 "L" STREET ANCHORAGE, ALASKA 99501 (907) 264-4111 GEORGE M, SULLIVAN, MAYOR DEPARTMEN~F OF HEALTH AND ENVIRONMENTAL PROTEOTION January 29, 1981 Frank L./Ingeborg G. Lentfer 5030 East 98th Avenue Anchorage, Alaska 99504 Subject: Lot 32 Block 2 Williamsom Subdivision Approval for your individual sewer and water facilities cannot be granted until the following items have been completed: (1) The septic tank pumped with a receipt submitted to this office. (2) An adequacy test needs to be performed on the existing leaching area. This test will determine if the system is adequate according to National Standards. A listing of private firms performing the test is enclosed. This report needs to be submitted to this department for our review. (3) The application shows the number of bedrooms exceeds the number the sewer system was originally designed for. An upgrade will be required~ the addition of a 500 gallon septic tank. Prior to any upgrade, a permit needs to be issued from this department. If there are any further questions, at 264~4720. SincereR, Robert C. Pratt, R.S. Associate Specialist please call this office RCP/ljw cc: Lomas and Nett[Leton 4449 Business ]Park Boulevard 99503 Larry Clarke, % Jack White Company 3201 C Street 99503 Tobben Spur land P.E. 8155 Cranberry ,St. Anchorage, Alaska 99502 Phone (907) 243-5302 MUNICIPALITY OF ANCEIORAGE DEPT. OF HEAL'rH & ENVIRONMENTAL p[~OTECTION MAR 1981 RECEIVED Joe Babka Jack White Co. ~201C Street Anchorage~ Alaska 99503 Feb. 25, 1981 ADEQUACY TEST Legal: Location: Owner: Residence: Water System: Sewer Sy~tem: Date of Test: Test Procedure:9 Lot 32, Block 2, William~on .~/D 5o3o E 98 Lindford 2 storey? 3 bedrooms Community Well ]~'r~ Municipal Records: Tank- 1OO0 gal steel Absorption- LoG Orib 8xSx9 Absorption Area- 660 sq.ft. ~oil ).{ating 220 (Area) Ins~ELlation Date; Aug. 1975 Feb. 20-23, 1981 System was inspected on Feb. 20. Liquid level in crib was Bottom of crib was 10.5 feet below ground. Tank was pumped on Feb. 2(~. Liquid level in crib on Feb al was 7'-O~-. On Feb. 23 liqud leve~L was 6'~9"o Approximately 200 gal wac du~l~ped into crib on .Feb° 23. Water level rose to 7'-~"- Test Result: The absorption cri'b has a volume of 478 ga]. per foot; of depth. During the first 20 hours after pumping the t~nk the liquid level in the crib subsided 9 inches. This is equivalent to an absorption rate of 420 gal per 24 hours. During the next 4~ hours the rate was 120 gal per 24 hours., ,~.¢ O~ ~ %}is crib is 9 feet deep. It is obvious that only the top 12 to 16 ~%~'"~1~. i]~ches of ~he crib is aba;orb:lng fluid at a rat~ close, to that ~%. ~ .~r(;quired. ~he bottom 6to 7 feet of the crib are clogged by ~/~j'4~ ~ ~¥~eposits. Since the system was installed in 1975 the clogging ~¥'"~"~-~ ~ate h~s been more th~ one foot per ye~. Zt can therefore be ~.. ..~%~ The Municip~. code requires an absorption rate of 450 gal per 24 Hours 3 oom ouso,