Loading...
HomeMy WebLinkAboutZODIAK MANOR ALASKA BLK 1 LT 11 GE fER ANCHORAGE AREA BOROb t}EPAR'rMENT 0F ENVIRONMENTAL QUALII~ 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCAtiON. SEPTIC TANK: MAILING ____ADDRESS_ LEGAL DESCRIPTION PFtONE. DISTANCE FROM WELL MATERIAL NUMBER OF COMPARTMENTS _ LIQUID CAPACIfY ~"~z- ;c-:'''~ LIQUID GALLONS. INSIDE LENGTH INSIDE WIDTH DEPTH__-- SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PiTS _] OUTSIDE DIAMETER _ OR WIDTH ,.;%,-)1 ,~'~, LENGLH~ ct/ / --.- ~ ~ __, DEPTH. LINING MATERIAL.~~ (~,(.¢,,,'*,.~L, (~.'l~¢'. "~(? ~ ~a..t-,~.~. . DISTANCE FROM WELl~)k~'-~ gZL"~'~ , BUILDING FOUNDATION NEAREST LOT LINE~ ~'.kb~ TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~'('¢ k~ SQ FT. TILE! DRA)N FIELD: x.... TRENC' WIDTH__ __DISTAN ¢~E/~'E f WEEN LR"4 ES __ f OTAL~I~d~GTH ., .,~q ES ___ , IN. TOTAL EFFECTIVE DEPTH: TOP OF TiLE TO FINISH GRADE__ DEPTH OF FILTER MATERIAL BENEA1H TILE IN. ABOVE TILE -- WELL: Typ E ¥'~,4, f?, :,'c ¢~ , DEPTH__ NEAREST LOT LINE __ , SEWER LINE DISTANCE FROM WATER , BUILDING FOLJNDAIION._ SAMPLE_ SEPTIC SEEPAGE , TANK , SYSTEM ..... CESSPOO~ NEAREST OTHER , SOURCES DISTANCES: ,~ ,r% (~.~),DIAGR_~A~M OF SYSTEM APPROVED ~ '¢ '~' ' G,A.A.B. NAME OF APPLICANT J NSTALLAI'I ON LOCATION LEGAL DESCRIPTION GREA'FE:R ANCHORAGE AREA BOF,,JUGH DE:PARTMENT OF' E:NVIRONMENYAL ~)[JALI~ PERMIT NO. __ SEWAGE DISPOSAL SYSTEM ~ APPLICATION AND PERMIT ~z,~--- INSTALLATION Of: SEPTIC 'rANK X SEEPAGE PIT FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIT WATER MAIN TO SEPTIC- TANI( DRAIN FIELD __ /() ' ____, SEEPAGE: PIT -, DRAIN FIELD ~ONPO~M TO ~O]~OUGH ~EOULATIONS I~£GA~DIN~ INSTALLATION. T.H.--I 7-17-72 ORGANICS ORGANIC SILT Radish Brown O,OI SILTY SANDY GRAVEL (GM) W/SOME COBBLES No water table Note: Hole excovated with tractor mounted backhoe. Roy Newbold Property b--ngineerlng ~ Geological Consultonfe LOG OF TEST BORING Anchorage Alaska MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTN AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SI-rE SEWER AND WATER FACILITY 264-4720 Application Date 12-8-86 GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Lotll Block 1Z Zodiak Manor Subdivisiof% t.ocation (address or directions) 4460 Mars Drive (b) Applicant Name Brad Heqg. imbathan Telephone: Home 274-8881 Business 272-6023 Applicant Address 941 David Place Anchorage, AK. 9950;[ (c) Applicant is (check one): Lending Institution []; Owner/builder []; Buyer i-]; Other [] (explain); (d) I_ending Institution Alask¢ Pacific Mortgage Address _ Anchors~.!e, AK. (e) Real Estate Company and Agent None/Rc~'F'inanc¢~ Address .. _ Telephone Telephone (f) the HAA to the following address: :AGLE RIVF~,,~t( TYPE OF RESIDENCE Single-Family [] Multi-Family [] Number of Bedrooms 3 Other 3. WATER SUPPLY Individual Well ~ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite ~ Public [] Com. munity [] Holding Tank [] Note: Il community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality' and status. 72-025 (lbB4) Page 1 of 2 EI:GINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE'-' SEARCH, DAI"A AND INFORMATION. As certified by my sea[ affixed hereto and as of the validation date shown below, I verify that my i nvestigatioa of this'H,~alt~¥ Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein, I further verify that based on the informatio~ obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm _ ,¢,~LS~IGINEEEING Address _ SR P~ 1_~6X Date EAGLE ROVER~ AK 99577 Telephone Approved'lb; ~' ~ ~--bedrooms by , Approved _:_ Disapproved Conditional Terms of Conditional Appr0yal CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 [1 WELL DATA ~% on Well Classificeti Tota~ Depth ~ MUNICIPALITY OF ANCHORAGE (MO~) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Description: LJ / If A, B, C, D,E.C. Approved (~¢N~ Date C~mpieted /¢2_ ~fo ~. ! ~ ;2 ._~- Yield Cased to Z.~ ~ Depth! of Grouting _~- ~ Static Water Level Casing Height Above Ground ['2_,, ~'( "~ Electrical Wiring in Condui Yt~,~) -- Separation Distances from Well: / To Septic/Holding Tank on Lot . c~ To Nearest Edge of Absorption Field on Lot Pump Set At ~. c,f Sanitary Seal on Casing CN) Depression Around Wellhead (Y/~) ; On Adjoining Lots t..~ ; On Adjoining Lots To Nearest Public Sewer Line _~,~"-t.~ f . To Nearest Public Sewer Cleanout/Manhole _ ~ ,~*'~" To Nearest Sewer Service Line on Lot . Water Sample Collected by , ~ ~. ~¢~~~ ' Date 1~ ~ ¢ -- Water Sample Test Results ~/Y~,~ B. SEPTIC/HOLDING TANK DA'FA Date Installed ~-g,C--'~Z- Size Standpipes¢/N) Air-tight Caps (~N) Depression over Tank (Y4~ Pumping/Maintenance Contract on File (Ye Holding Tank High-Water Alarm Separation Distances from Septic/N~cldi,~g Tank: To Water-Supply Well ~'~-- t To Property Line ~_ To Water Main/Service Line ~ ~' Course No. of Compartments Foundation Cleanout (Y/I~ Date Last Pumped ; for Temporary Holding Tank Permit (Y/¢ To Building Foundation ...¢0 " To Disposal Field /~..z~ *' To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72-026{11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata _ Date Installed ? -- '~-~- Width of Field ~---"~ ~ 73g Square Feet of Absorption Area Depression over Field (Y/~_ of Laat Adequacy Test Results Separation Distance from Absorption Field: To Water-Supply Well ~0 Type of System Design / · -- Length of Field Depth of Field _ /'2_. f Gravel Bed Thickness '~' ! Standpipes Present CN) Date of Last Adequacy Test To Building Foundation Lot To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments To Property Line To Existing or Abandoned System on ; On Adjoining Lots ~c~ To Cutbank (if present) D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) ,~V.//~,~ "Pump Off" Level atvent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify t hat,~ i~ ~¢ ~ ~c~ ~v~li~Go r conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed _~.~ 'i~X Date Company * t CA No. ~'" ~ --/.¢ ~, ~ .'~ .,. ,.',, ...... Receipt No. Date of Payment Amount: $ Page 2 of 2 72-026 (H/84) CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC. Anchorage, Alaska 99518 13rinking Water Analysis Report for Total ColifOrm Bacteria TO BE COMPLETED BY WATER SUPPLIER EG- PRIVATI-- WATER SYSTEM Mailing Address City Stale Mo. Day Year SAMPLE TYPE: -¢l~-R ou tin e [] Check Sample (for routine sample with lab ref. no. Lq Special Purpose Zip Code ) [] Treated Water -4~Untreated Water SAMPLE NO. LOCATION 2 l I I 4 l I Time ColLected Collected /ffla/ TO BI-'- COMPLETED BY LABORATORY [)ate Received Time Received Analytical Method: Analysis shows this Water SAMPLE to be: [t~ S;tisfactory [] Unsatisfactory [3 Sample too long in transit; sample should not be over 30 hours old at examination to indicate reliable results. Please send new sample via special delivery mail. f2/o,/x /OOO Membrane Filter * No, of colonies/lO0 mi. Lab Ref. No. Analyst I I I I Result* I-F1 BAO'f'ERIOLOGICAL WATER ANALYSIS RECORD READ INSTRUCTIONS ~ Membrane Filter: Direct Count Coilformll00ml BEFORE COLLECTING SAMPLE Verification: LTB Final Membrane Filt~e~its: , ~'/ TNTC := Too Numberous'To Count OB = Other Bacteria BGB Date_ Time: ~) Coilformll00ml Is~O0 a.m. T~-ector -- ~'~pector Inspector ~ ~l~°mments Conditional Approval Date Sewer Installed Permit No. ~pt~'Tank Soils Rating Well To Absoretlon Are~ Well to Tank Heldln~' Tank Size Well Log Received APPLICANT FILLS OUT LOWER HALF ONLY Procerty Owner 7 /~)/T) /-']C~, ,- Mailing Address Buyer ~7.?/~ Lending Institution // Z W.3 ~ ~/ ~ d'/ ' ~ ' 'Address /~) Realty Co. & Agent Address Legal Description Street Location Type 9f~sidenc¢ L%Slngle Family [] Multiple Family E] Other Phone Phone No. of Bedrooms /?) // /u ,~ / Water, S~lpply [/~dividua [] Community [] PuL)lie Utility Sewage~Dlsposal L"[ Individual [] Public Utility [] Holding -rank ATTACH WELL LOG. A well Icg Is reamree for all wells drilled since June 1975. For wells drilled l)rier [o that date. g~ve well depth (attaci' log if available.) / Year Individual rmtelled: _ -- When Connected to Public Utility: NOTE:: Tllr~ INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INI'I'IATED. JAIVIES [3, ROBEEI::II'S, PE, RLS ENGINEER & S U I:lV E YO I:! (90'7) SEPTIC SYSTEM ADEQUACY TEST DATE 7-/~-~ _ CLIENT: Telephone LEGAL DESCRIPTION: SEPTIC TANK: LEACH PIT: DRAIN FIELD: Material 'Type Size /~.~/ Number Bedrooms .~ Surcharge Test __.~t,~/. Rate of percolation Required Tank Size gal. water; 0.80 (150 x No. bedrooms) min. gal./day I ~0'7 East ~4 th Avenue SOUTHCENT'RAL REGIONAL OFFIC[: f MUNICIPALITY OF ANCHORAG~ DEPT. OF Hi:;.i[ I & JUL 1 'j 1981 RECEIVF_.D 437 E. STREET SECOND FLOOR ANCHORAGE, ALASKA 99501 (907) 274-2533 ~o. BOX 615 KODIAK, ALASKA 996'15 (907] 48~-3350 P.O. HOX 1207 SOLDOTNA, ALASKA ~669 (907] 2~2-5210 P.O, BOX 1709 VALDEZ, ALASKA ~)~8~ (907) 835~98 P.O. BOX I0~ WASILI.A, ALASKA 99687 [907) 376' 5038 &~].y 8, Z981 Cortland Braberg 8429 JupLter Drive B2~chorage, Alaska 99507 Subj ect: 1981 Sewer Extension, Pluto ])rive Wastewater Review 11812].-])A036 Zodiak Manor S/Ds Anchorage Dear bir. Broberg: a reduction o~ the protective radii for the well located on Lot 26, Block 6, Zodiak Manor S/D. We hereby grant a waiver of 18AAE 80 020 which ~:eClU~res a rain]taunt sepe[ation of 75 feet between a private single family seperation of 100 feet between a private single fam~il.y well and a sewer main cleanout to 40 feet for the suhjeet project. The project :is here by approved for construction for ~he iLems with which that departnent is concerned. ThRs letter constitutes the permit required by A.S. 66.03.720 (a) for approval of sewerage systems, If you ]lave an quest]one, fee] free to contact me. cc: A.D.II.E,P. TI,bi/town SOUFHCEN?RAL REGIONAL OFFICE .~une 29, 1981 ],fY $. tt,l,qOOtlO, 437 E. STREET SECOND ANCHORAGE. ALASKA 09501 fOO7] 274.2533 KODIAK. ALASKA 99615 (.9071 48~.3350 SOLDOTN,4. ALASKA 99669 [907] 262 5210 (907) 8354~8 WASIL~. ALASKA 99687 Cortland it. Bl:obel:g Professionnl Engineering 8429 .lup[ter Drive Ancbo rage, Alaska 99507 Subject: 1981 Sewer Extension, Pluto Drive Wastewater Review # 8121--DA036 Zed[ak~,,lan~)r' S/I), Anchorage MUNiCiPALITY OF ANCHORAGE DEPT. GF HFALI~i & ENV[RONMENIAL i ~ O~ECIION JUl. 2/981 RECEIVED Dear Mr. Bceberg: We have reviewed tile pi.aha and ~xpeclficatinns for the subject project, the proposed a]:tgmnent wi.l.[ infr£nge upnn the proteetl~re well on lot: 26. this time as redE[ of the I [lave enclosed a copy of the State Drinking Water Regulation ~Jhich defines tbe m/n.Lmurn contaminate separat[on dLstance of lO0 feet between a private well and a community sewer line clean-out, and 75 feet between a private well and a community sewer line. (18 AAC 80.020 d) providing site conditLons justify a ].esse. r distnnce. r[~l]OI]l;lS L. 5hlrre] 1 A. D. H , E. I?./''V' A, W ,S, [J, TLH/wih R&M Civil Engineers ENGINEERING c% GEOLOGICAl. CONSIJLTANTS 229 EAST 51st. AVE. - P.O. BOX 6087 - ANCHORAGE, ALASKA 99503 TELEPHONE 907 -279-0,183 TELEX 090-35410 Geologists Land Surveyors JAMES W. [lOONEY, P. E. MALCOI_M A, MENZIES, P.E., L.S. JAMES H. WELLMAN, P.E. ]tdy 18, 1972 R & M l~Io. 26540-8 HAL_PFI FI. MIGLIACCIO Mr. Roy Newbold 4121 Grape Place, Apt. ~4 Anchorage, Alaska 99504 RE: Test Hole and SoJ~[ Log Report for Sanitary System Lot ]1, Block 1, Zodiak Manor S/d Dear Mr. Newbold: We are submit't{ng herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance wkth your request of July 17, 1972, and those procedures outlined in a letter dated September 13, ].971 by 1VL~. Roll Stzicl4and of the Greater Anchorage Area Borough Department of Envirommen'tal Quality. A single test hole was pat down within the Lot ]1 area for 'the purpose o~ deining general subsurface so{1 conditions for 'the proposed sanitary system. Excavation was accomplished with a tractor-mounted ba hoe and the test hole was extended to a ~otal depth of 12 feet below ground st~rface. The ~{na]. log prepared for the tes't hole has been included in ]Drawing A-01. Ground water was not encountered in-the test hole. We appreciate being given this oppoz~anlty 'to be of service to yon. Should you have any questions with regard to the above, please do not hesitate to contact US. Very truly yours, R & M ENGINEERING & GEOLOGICAL CONSULTANTS ~-/ James W. Rooney JWR:wb Enclosc~re xc: Greater Anchorage Area Borough¢ JUL 2 0 BILL SHEFFIELD, GOVERNOR ~]~. O~~ ~VI[~tONMENT/~H~ ~ON§ERVATION~ ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, ALASKA 99501 274=2533 Alaska Environmental Control Services 1200 West 33rd Avenue Suite B Anchorage, Alaska 99503 October 15, 1984 NOV 2 i984 SUBJECT: Waiver Horizontal Separation Between Well and Septic Tank, Lot 9, Block 1, Zodiak Manor (8521-WA-048) Dear Sir: The Department has reviewed the subject waiver request and hereby waives the horizontal separation between the well and septic tank to 95 feet on the subject property for a 4 bedroom single family residence only. Sincerely, r~u~ce E. Erickson District Engineer BEE/dd