HomeMy WebLinkAboutGREENBROOK BLK 4 LT 5Greenbrook lock 4 Lot 017-431 -12 Municipality of Anchorage Development Services Department Building Safety Division . On-Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak, us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND]OR WELL INSPECTION REPORT Permit Number: OSPllll09 PID Number: 017-431-12 N .... JOERENE M. HOUT Wastewater System: [] New [] Upgrade Address: 6801 Teresa Circle~ Anchorage~ AK 99516 ABSORPTION FIELD Phone: Number of Bedrooms: 3 I~ Deep Trench [] ShallowTrench [] Bed [] Mound [] Other: LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: 1.2 GPD/Ft2 11 Ft, Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 4 5 Greenbrook 5.52 Ft. 5.48 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: - 0.4 Ft. 38 Ft. Well: [] New [] Upgrade Gravelwidth: Numberofli .... I Distance between lines: 3 Ft. ]I -' Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Class A Ft. Ft. 416 Ft2 D3034 / F810 Driller: Date Drilled: Static Water Level: Installer: Date Installed: Ft. Mike Anderson ~ Yield: GPM Pump Set at: Casing Height Above Ground: Ft. Ft. TAN K SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: To Septic Absorption Lift Holding ~ublic/Private Manufacturer: Capacity: ~ Tank Field Station Tank Sewer Line Anchorage Tank 1000 Gal. Well 200'+ 200'+ SA NA 25'+ Material: Number of Compartments: Steel 2 Surface Water leo'+ lOOt+ NA NA ~ / LIFT STATION Lot Line 5~+ 10~+ NA NAA Size: Manufacturer: Gal. Foundation St+ 10T+ NA NA "Pump on" level at: "Pump off' level at: in. High water alarm at: Curtain Drain NA * 50'+ NA NA Pump Make & Model Electrical Inspections performed by: Remarks: · None known. Existing septic tank was decommissioned BENCH MARK per code, Location and Description: Bottom of siding Assumed Elevation: 100 Ft. Engineer's Stamp Inspections performed by: ArcTerra Dates: 1sT & 2ND 6/22.23/201! Devel°pment,,/__Services Department Approval Reviewed and approved by: Ff~..//'.~ £~,~ ~-">c-~ Date: ~ ~ r__{~ AS-BUILT SYSTEM DETAILS/SITE PLAN GREENBROOK BLOCK 4, LOT 5 / / .x/w~ Permit 0SPl11109 / / ,///W PID# 017-431-20 NE~ 1000 ~A~. S.T. ~ 3~-~-~.~-~-~.~.~ i / ~'/ ~~ EXISTING ~ / ~:/ /~a HOUSE .'~.v.v.v.v.'.v.'.v.v.v.v ~ ~ - ~. v.v.v.v, v ~ SCALE: 1" = 30' A-D=17.1' B-D=10.8' < ~ < = ~=~ 5B-E=43.6' i~ FINAL GRADE o I .0-.:36, , B-F=5~ .5 ............. ~ 5 -~ ~000~ IX ~ ~ SEWER ROCK ~ TANK I ~%OF ~.~ SCALE: NTS * 6801 TERESA CIRCLE ~~ T~~e~ ANCHO~GE, AK 99516 eou~o~: BOUNDARY ~: BMW ~ ~% ~/=M/t.[, ¢~ A~UILT: REJ D,m: 6/15/11 't..~ ..... , ~. 99577-~ PINAL (3MADE SEWER ROCK Permit Number: Tax Code Number: Work Type: Permit Effective Dates: Design Engineer: Subdivision: Site Legal Address: Owner/Address: Site Mailing Address: On-Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 OSPl11109 O1743112OOO Septic Upgrade June 20,2011 to ARC TERRA CONSULTING INC GREENBROOK June 19,2012 GREENBROOKBLK 4 LT 5 G:2839 Depar tm. eh t ARC TERRA CONSULTING INC 20441 PTARMIGAN BLVD EAGLE RIVER AK 99577 6801 TERESA CIR, Anchorage Lot Size in Sq Ft: 47444 Total Bedrooms: 3 This permit is for the construction of: Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 017-431-12 Property owner(s) JOER EN E HOUT Mailing address6801 TERESA CIRCLE, ANCHORAGE, AK Site address 6801 TERESA CIRCLE, ANCHORAGE, AK Day phone Zip Code 99516 Zip Code 99516 Legal description (Sub'd., Block & Lot) GREENBROOK BLOCK 4, LOT 5 Legal description (Township, Range & Section) Lot Size47,444 Sq. Ft. Number of Bedrooms 3 THIS APPLICATION IS FOR ([] all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. ARCTERRA (Signature of propert~er or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: CONSULTING, INC 212 E. 51st Ave, Anchorage, AK. 99503 ) 868-3791, Fax (907) 868-3793 June 14, 2011 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Upgrade Sewer Permit - Greenbrook Block 4, Lot 5 The owner has requested we proceed forward to obtain a septic permit to upgrade the failed leachfield on the subject lot. The general slope of this lot is from east to west at a grade of approximately 3-7%. On June 4, 2011 a testhole was performed to investigate soils and groundwater. The results of this test are attached for your review. The proposed upgrade will serve the existing 3-bedroom house. We propose to install one 38' long deep trench. Groundwater was not encountered at during excavation or at monitoring. The property and adjacent lots are served by a Class A community water system. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 868-3792 / FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. Attachments: On-Site Sewer Application Wastewater Absorption System Details / Site Plan Soils Log/Percolation Test Owner/Contractor Specs 20441 PTARMIGAN BLVD · EAGLE RIVER, AK 99577-8736 ° PH (907) 868-3791 ° FAX (907) 868-3793 WASTEWATER DISPOSAL SYSTEM DETAILS GREENBROOK BLOCK 4, LOT 5 3 PROPERTY WATER LINE & EA PRIOR TO 3 ON PROPERTIES SERVED BY CLASS A WATER SYSTEM Scale: 1"= 100' PAGE 2 OF 2 PREPARED FOR: JOERENE M HOUT 6801 TERESA CIRCLE ANCHORAGE, AK 99516 FIELD BOOKS COMPUTED: -- BOUNDARY:BOUNDARY ~-BMW ST*K,Ne STAKING ~ --~'~"D- ASSUILT: REJ ~ 6/13/11 ^CAO riLE: FILE ~oB No.: 11-056 WELL & WASTEWATER DISPOSAL SYSTEM GREENBROOK BLOCK 4, LOT5 REMOVE EXISTING S.T. PER CODE & INSTALL NEW 1000 GAL. S.T. W/2 POST TANK COs & NSTALL NEW 38'L x 3'W x 5'D 12' MAX DEPTH LOT 6 EXISTING 3-BP HOUSE TH11-1 DETAILS/SITE PLAN FLAXQI~-.ROPERTY L1NE$ ~4/ WATER L~N.E & EASEM--~E~TSO/~/t. PRIOR TO C~:~STRUCTION~ v~, DESIGN DETAILS 3 BDRM X 150 GPD = 450 GPD LOT 5 KEY BOX 450 GPD/1.2 GPD PER SQ. FT. (2.8 MIN/IN.)= 375 SQ. FT Scale: 1"= 40' (375 / 2 x (5' GRAVEL) = 37.5 FT. TRENCH USE 1 TRENCH - 38' (L) X 2' (W) X 5' (D) PAGE 1 OF 2 NO PUBLIC WELLS WITHIN 200' OF Total depth of system is 12' max from odginal grade. PROPOSED SYSTEM. Total depth of gravel below distribution pipe is 5' NO PRIVATE WELLS WITHIN 200' OF ' PROPOSED SYSTEM EXCEPT AS NOTED. NOTES: NO SEPTIC SYSTEMS WITHIN 200' OF PROPOSED WELL EXCEPT AS NOTED. 1. INSTALL NEW 1000 GAL & INSULATE TANK IF <4' COVER. 2. INSULATE TRENCHES WITH 2" HD BURIAL FOAM IF < 3' OF FILL. MIN. 2' FILL WITH INSULATION, >3' COVER NO INSUL REQ. 3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK. 4. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT ~~'~,~, WELLS, SEPTICS EASEMENTS, PROPERTY LINES, ETC... JOERENE M HOUT 6801 TERESA CIRCLE ~'~ ANCHORAGE, AK 99516 ~ FIELD BOOKS COMPUTED: BOUNDARY: BOUNDARh STAKING: STAKING CH~C~: KMD '~- '-,.j., ^c^9 mE: FILE Joe Ne.: 11-056 ~/~, AK. 9957? Performed for: A ¢TERRA 212 E. 51 st Ave, Anchorage, AK. 99503 (907) 868-3791, Fax (907) 868-3793 SOILS PERCOLATION TEST Joerene Hout Date Performed: 06/4/11 Project: Depth (Feet) 11- 12- 13- 16- 17- 19- 20- Greenbrook Block 4, Lot 5 Org/OL GM-SP/GP mod dense, trace of silt, sand increasing w/depth w/cobbles to 1' B.O.H. TEST HOLE # TH 11-1 SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? NO Depth to water after monitoring? NO What depth? NA Date? 6/13/11 Reading Date Gross Net Depth to Net Time Time Water Drop 1 6/4/11 1:00 6" 2 1:10 10rain 25/16" 3 11/16" 3 * 1:11 6" _ 4 1:21 10min 25/16" 3 11/16" 5 * 1:22 - 6" 6 1:32 10 min 2 6/16" 3 10/16" 7 * 1:33 6" 8 1:43 10 min 2 7/16" 3 9/16" 9 * 1:44 6" 10 1:54 10 rain 2 8/16" 3 8/16" 11 * 1:55 6" _ 12 2:05 10 min 2 8/16" 3 8/16" · Water Added Percolation Rate 2.86 (min/in) Perc Hole Diameter 6" Test Run Between 4.5 feet and 5.5 feet I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. c TERRA ~ CONSULTING~ INC 212 E. 51 st Ave, Anchorage, AK. 99503 Office (907) 868-3791, Fax (907) 868-3793 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS LEGAL DESCRIPTION: GREENBROOK BLOCK 4, LOT 5 GENERAL: 1. The scope of this project includes the installation of a septic tank and or drainfield to serve a single-family residence on the referenced property as delineated on the attached Municipality of Anchorage (MOA) permit and site plan. Construction shall be in accordance with the approved site plan and design drawings; MOA permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 2. ArcTerra Engineering & Surveying, Inc. (ArcTerra) assumes no responsibility of the accuracy of the as-built survey provided by the owner or owner's representative. 3. The owner or contractor is responsible to notify the engineer of any discrepancies noted on the design plans or drawings prior to commencing work. These discrepancies could be, but not limited to, possible encroachments, surface water, varying soils, unplatted easements, types or use of dwellings on or adjacent to property, nearby public wells, etc. 4. The contractor shall be responsible for locating any necessary underground utilities, easements, property lines and surface water. The owner and/or contractor shall ensure, if deemed appropriate, that a registered land surveyor prior to construction flags all setbacks. The contractor shall be responsible for verifying all pertinent separation distances and component layout. 5. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. 6. The MOA Development Services Department On-Site Water & Wastewater Program must certify contractors installing wastewater disposal systems. Owners installing their own systems must also receive prior approval from said MOA Department. SEPTIC TANK / HOLDING TANK [ LIFT STATION INSTALLATION: 1. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 2. The septic tank shall be sufficiently bedded with proper material and compacting to prevent damaging, settling or shifting of the tank. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above the final grade. 4. Septic tanks installed with less than 4 foot of cover shall be insulated. The contractor will ensure that the fill over the tank does not exceed the burial depth rating. 5. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic Greenbrook B4, L5 June 13, 2011 Page 2 of 3 tank). These cleanouts shall be located on undisturbed soil not more than 10 feet from the tank. The second cleanout, in line, shall be to clean toward the septic tank. 6. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. 7. All H.D.P.E. tanks shall have a vertical length of 4-inch perforated drainpipe besides the tank extending to the bottom of the tank to above grade to monitor ground water. 8. All tanks shall be anchored when there is not enough adequate soil cover to resist buoyancy forces in high-groundwater areas. 9. All holding tanks and lift stations shall have an audible and visual alarm inside the residence. 10. All lift stations shall be wired in compliance with the Uniform Electrical Code and all MOA guidelines. 11. The contractor shall remove the old tank, or abandon it in compliance with the Uniform Plumbing Code. The contractor is solely responsible for the abandonment procedure. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: 1. Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavaction become smeared, they must be raked or scratched (roughed-up) before gravel (sewer rock) placement. 2. Once the sewer rock is installed, the distribution pipe is installed level with the perforations facing downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 4. Monitoring tubes shall be four- (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. 5. Backfill over the final gravel layer must not be less than twenty-four inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. 6. All advanced technology waste water disposal systems (Advantex, Biocycle, Intermittent Dosing Sand Filter, etc...) shall be constructed, installed, maintained and monitored per manufacturer's specifications and MOA requirements. MINIMUM MATERIAL SPECIFICATIONS: 1. A MOA approved septic tank manufacturer must construct any septic tank proposed for installation. 2. The following pipe materials are MOA approved for use in septic system installations: _Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes 20441 PTARMIGAN BLVD · EAGLE RIVER, AK 99577-8736 · PH (907) 868-3791 ° FAX (907) 868-3793 Greenbrook B4, L5 June 13, 2011 Page 3 of 3 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. If deemed necessary, a sieve analysis should be performed. 7. When sand is being used as a filter material, its gradation specification must conform to current MOA or ADEC requirements. INSPECTIONS: Typically there will be three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the sewer rock, distribution lines, standpipes, and cleanouts, but before the placement of the silt barrier, insulation, or any other backfill. 3.The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required, especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. The inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractor's activities. The owner shall contract with the contractor to perform the work outlined in these specifications and attached plans and in accordance with the attached MOA permit. All materials, components, and construction practices shall comply with the MOA's and the State of Alaska's latest ordinances, regulations, or policies regarding wells and septic systems. The failure of the inspecting engineer to notice a material or construction non- compliance does not relieve the contractor of his/her responsibility to correct such deficiency. There will be no contractual arrangement existing between the contractor and ArcTerra. ArcTerra shall be the owner's representative and will inspect the work as stated above to document the contractor's activities. Final acceptance of the contractor's work rests with the owner and the MOA. ArcTerra shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. ArcTerra's inspecting engineer will not be responsible for the construction means, methods, and techniques, sequence, procedures or the safety precautions incident to this project. BY PROCEEDING FORWARD WITH THE INSTALLATION OF THE WATER AND/OR WASTEWATER SYSTEM (S), THE PROPERTY OWNER, CONTRACTOR, AND WELL DRILLER ACKNOWLEDGE HAVING READ AND ACCEPTED THESE SPECIFICATIONS. 20441 PTARMIGAN BLVD · EAGLE RIVER, AK 99577-8736 · PH (907) 868-3791 ° FAX (907) 868-3793 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENI'AL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ~AME 2i9'7 /;7 / r i, k LEGAL DESCRIPTION lot ;f-/ l ck g PHONE [] NEW LOCATION DISTANCETO: J Well . L//)~' '~ ~YD'f/¢' Absorption Manufacturer~r Liq. capacity in gallons DISTANCE TO: IF HOMEMADE: Well Inside length Dwelling Manufacturer Well/ DISTANCE TO: NO. of lines/ Length of each Top of tile to finish grade Foundation /1~! Total length of Material beneath tile Dwelling '7 Mate'ia'yfeH Width Material Nearest lot line /.~--- *' Trench width/,-) /¢,& nches inches NO. OFBEDROOMS~..~ PERM'TNO' 20¢¢7 No, of compartments 2 Liquid depth PERMIT NO. Liquid capacity in gallons PERM IT NO.(~2 0 ~/4 7' Distance between lines Total effective absorption area 400 Length Width Depth PERMIT NO. Type of crib Crib diameter Crib depth Total effective absorption area Well Building foundation Nearest lot line DISTANCE TO: Class Depth Driller Distance to lot line DISTANCE TO: Building foundation Sewer line Septic tank OTHER PIPE MATERIALS p F~ SOIL TEST RATING INSTALLER 6'er, e REMARKS PERMIT NO. Absorpt on area(s) APPROVED DATE LEGAL 72-013 (Rev. 3/78) PERMIT NO. E)EPRRTMENT ~ HERLTH RND EN, ~ENMENTHL ~./.0TEE:T~0N 825 "L" STREET~ RNCHORRGE, RK. ~950i 264-4720 ,],~-~--S I TE 5E~qEF: F"EF:f4 Z T ( 820947 ) RPPLICRNT LOCRTION LEGRL GENE FOWLER L5B4 GREENBROOK 2157 FRIRBRNKS ST 99505 LOT SIZE 268-8845 999999 SQURRE FEET TYPE OF SOIL RBSORPTION SYSTEM IS: TRENCH MRXIMUM NUMBER OF BEDROOMS SOIL RRTING THE REQUIRED SIZE OF THE SOIL RBSORPTION SYSTEM IS: [:.EF'T.' ," .... 8. 5 LE~-4i_3TH= 45 i3F-:R%."EL [:.EF'TH= 4 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRINFIELD. THE DEPTH OF R TRENCH OR PIT IS THE DISTRNCE BETWEEN THE SURFRCE OF 'THE GROUND RND THE BOTTOM OF THE EXCRVRTION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. THE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRRVEL BETWEEN THE OUTFRLL PIPE RND THE BOTTOM OF THE EXCRVRTION (IN FEET). F-:Ei_i!L! IRE[:. '_--]EP]- I C: TR~-4P-: $ I ZE= i£~¢_-~O PERMIT RPPLICRNT HRS THE RESPONSIBILITY TO INFORM THIS DEPRRTMENT DURING THE INSTRLLRTION INSPECTIONS OF RNY WELLS RDJRCENT TO THIS PROPERTY RND THE NUMBER OF RESIDENCES THRT THE WELL WILL SERVE. T~.J,], (2) I ~4'_:.PEE:TI,]~5; R~:E RE~]LIlRED BRCKFILLING OF RNY SYSTEM WITHOUT FINRL INSPECTION RND RPPROVRL BY THIS DEPRRTMENT WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTRNCE BETWEEN R WELL RND RNY ON-SITE SEWRGE DISPOSRL SYSTEM IS i00 FEET FOR R PRIVRTE WELL OR i50 TO 200 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTRNCE FROM R PRIVRTE WELL TO R PRIVRTE SEWER LINE IS 25 FEET RND TO 8 COMMUNITY SEWER LINE IS 75 FEET. OTHER REQUIREMENTS WRY RPPLY. SPECIFICRTIONS RND CONSTRUCTION DIRGRRMS RRE RVRILRBLE TO INSURE PROPER INSTRLLRTION. F'Ei~:f.1 I T F.'--:-"F' I ~:ES [:,E,::Ef. IBER ~e-l.. I CERTIFY THRT ±: I RM FRMILIRR WITH THE REQUIREMENTS FOR ON-SITE SEWERS RND WELLS RS SET FORTH BY THE MUNICIPRLITY OF 8NCHORRGE. 2: I WILL INSTRLL THE S'T'STEM IN RCCORDRNCE WITH THE CODES. 5: I UNDERSTRND THRT THE ON-SITE SEWER SYSTEM MRY REQUIRE ENLRRGEMENT IF THE RESIDENCE IS~L~,~U_IDE~' MORE THRN 5 BEDROOMS. RPF'L I CRNT G~NE FOWLER MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVl RONIVIENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG- PERCOLATION TEST [] SO~'LS LOG" [] PERCOLATION TEST 8 SLOPE 10 12 13 14 15 16 17 18 19. 2O WASGROUNDWATER [ ENCOUNTERED? O P E IF YES, AT WHAT DEPTH? ~ Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE --~, ~ (minutes/inch) ,TEST RUN BETWEEN '~ FT AND ~-~ FT 72-008 (6/79) DATE: TO: FROM: SUBJECT: M c pa ity Anch° g MEMORANDUM January 19, Laura Crow 1983 Sewer and Water Program Request for Refund - Account #2460 Please make the necessary arrangements for the following refund. A private engineering firm has performed the inspections in lieu of this department. Thank you. Gene Fowler 2137 Fairbanks Street Anchorage, Alaska 99503 Lot 6 Block 4 Greenbrook Subdivision - 20°00 Lot 5 Block 4 Greenbrook Subdivision - 20.00 Total: $40.00 Receipt # 205966 Laura J. Ward Senior Office Assistant attachments 91-010 (5/78) MUNICIPALITY OF ANCHORAGE Development Services Department:. Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 017-431-12 Expiration Date: S -3 —2-0 Z3 1. GENERAL INFORMATION Complete legal description GREEN BROOK BLOCK 4, LOT 5 Location (site address) 6801 TERESA CIRCLE, ANCHORAGE, AK 99516 Current property owner(s) DAVID SMITH Mailing address Real estate agent Day phone 6801 TERESA CIRCLE, ANCHORAGE, AK 99516 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 Day phone 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well ❑ Private Septic Water Storage ❑ Holding Tank ❑ Community Well ® Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ $550 Date of Payment Sr r? Receipt Number. S (j d Q 3 COSA # OSC211088 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Address 13030 SUES WAY, ANCHORAGE, AK 99516 Engineer's Printed Name CURTIS HUFFMAN, PE Date 3/4/2021 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the or— system and maintenance. The operational life of all well and septic systems are subject to i these various and dynamic characteristics and are outside the control of the evaluator of the e�P• well and septic system. Therefore, any estimate of how long a system will function satisfactory rg••• •� �� TM for current or future occupants or guarantee that no unseen encroachments, deficiencies or % *. ` �•* discrepancies exist can be given by First Water Consulting & FWI.S . • • • • • .. • • • • • r 6. DSD SIGNATURE Curtis Huffman d' C3 1 .1.., • ���/ K System #1 Approved for 3 bedrooms rF •. �� r �,l SSONA4.� System #2 Approved for bedrooms \\� PROFi * lI Disapproved Conditional approval for bedrooms, with the following stipulatioRT,(((((rf((( TY OF �J yon WAT RR AN J P T !:V.'arER z- �- �- ,,JiJJ1J SERVlG�?, t^�I Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklisp Legal Description: GREENBROOK BLOCK 4 LOT 5 Parcel ID: 017-431-12 If more than 1 septic system on lot: COSA Checklist # _of A. WELL DATA — CLASS A WELL ❑ Well log is filed with Onsite (or attached) Date drilled Total depth _ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) _in. Date of flow test for COSA Static water level at beginning of test _ft. Comments B. TANK DATA Age of tanks) 10 years Tank type/material SEPTIC /STEEL Measured operating fluid level in septic tank 50" ® Standpipes/foundation cleanout per record drawing Date of pumping 3/3/21 Structure served by this system _ Well production at time of test _gpm Water storage tank volume_ gallons Well disinfected for coliform test? ❑ Yes ❑ No ❑ Coliform bacteria is Negative Nitrate _mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample C. LIFT STATION ❑ Required maintenance completed Age of lift station _ years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 6/22/2011 Adequacy test date 3/3/2021 ® ALL standpipes present per record drawing Results M Pass For 3 bedrooms Total measured depth from grade 11.5 ft (max) Fluid depth prior to test 40 in Measured depth to pipe invert from grade 5.0 ft (min) Water added 860 gal ❑ N/A — pressurized field New depth 62 in ® Monitor tubes go to bottom of effective. If not, state depth into effective NIT DEPTH IS 6.5' BELOW INVERT. Elapsed time 1320 min ® Code -required soil cover over field Final fluid depth 34 in ❑ System presoaked Absorption rate 450+ and (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N date of test) Gallons introduced gallons If yes, enter date Fes, Comments/Deficiencies: E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑ Yes if No *5 Community Sewer Manhole/Cleanout > 100' ❑ Yes if No ft ❑ Yes if No Neighboring Tank > 100' ❑ Yes if No ft Private Sewer/Septic Line > 25' ❑ Yes if No Absorption Field on Lot > 100' ❑ Yes if No ft Holding Tank > 100' ❑ Yes if No Neighboring Absorption Fields > 100' Water Service Line > 10' ® Yes Animal Containment > 50' ❑ Yes if No ❑ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ❑Yes if No ft 0 Yes if No From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No *5 ft Surface Water > 100' ® Yes if No Property Line > 5' ® Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ® Yes if No ft Private Wells > 100' ® Yes if No Water Main > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Water Service Line > 10' ® Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ® Yes if No ft If absorption field is under driveway comment below Property Line > 10' ® Yes if No _ ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' ® Yes if No ft Water Service Line > 10' ® Yes if No ft Community Wells > 200' ® Yes if No Surface Water > 100' ® Yes if No ft F. ENGINEER'S COMMENTS *PER CODE AT INSTALLATION. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. a. AW Awl TM xv • * �� �._ Curtis HuffmanCE •: Fo 3(4/20�11•������,� ft ft ft ft ft ft ft ft MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 017-431-12 ,.., HAA# :~:-1~'~'~.~,%i' ...... :~.~'~" \ 1. GENERAL INFORMATION Complete legal description Lot 5; Block 4; Greenbrook Subdivision e Location (site address or directions) Property owner Mailing address Gene Fowler C/O Prudential 6801 Teresa Circle .Anchorage, AK Day phone Vista REal Estate Lending agency Mailing address ' Agent Gl~ia Ho]f]~ch/Vista Real EStat~ Address ' 4241 "B" Street Anchorager AK Unless otherwise requested, HAA wi//be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water %j XX NOTE: Day phone Day phone 99503- 273-7335 If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: XX If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91 ) Front MOA ~21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Ala~k~ Wa~er & Was~ewaSer Name of Firm ~ .......a+~.,~.a I,~e0 Phone Address 7320 E~s~ Chester ~:~s. C~rcle A~ch.orage, ~aska Eaginee(s signature Date ALASKA WATER & WASTEWATER CONSULTANTS, IS TO BE PAID $900.00 AT CLOSING FOR ENGINEERING SERVICES PERFORMED. DHHS SIGNATURE Approved for Disapproved. bedrooms, Conditional approval for INC. bedrooms, with th-e following stipulations: Additional Comments By: 'fil'li[']l The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) ~¢k MOA ~21 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907),'3a¢34¢48'44 Health Authority Approval Checklist A. WELL DATA Well type I(~ B, or C, attach ADEC letter. ADEC water system number ~1 (y/N.,,~)t (Y/N) Date completed Sanitary se _ Cased to____ WireC~iir~gp~ri~ilo(t~bctO~ (g~/o~ic)  AT INSPECTION Date of test ~ __ Static water level ~__ Well production .... g.p.m. -'--~_ g.p.m. WATER SAMPLE RESULTS: ~ Coliform Nitrate Other bacteria % Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Date installed H/9 ~. Tank size Foundation cleanout (Y/N) ¥ Date of Pumping /O/~ ¢//¢/t~ JO0~ Number of Compartments ~- Cleanouts (Y/N) Depression (Y/N) ~J-O High water alarm (Y/N) /'J Pumper /~ '~ C. ABSORPTION FIELD DATA Date installed ~ / / (~ ~-' / Length ~ Width Effective absorption area .400 Date of adequacy test /o/2-3 Soil rating (~l~:d:YfF or fF/bdrm) / 2~O System type / / / ~'. ~' Gravel thickness below pipe '~ Total depth Monitoring Tube present (Y/N) y Depression over field (Y/N) Results (Pass/Fail) /~r~.~ For ~ bedrooms depth 'n absorption field befpre test (in.); D¢-~ Immediately after 102. 7' Fluid gal. water added (in.): ~' Fluid depth ,~¢'7~-~;~ '~(ins) Minutes later: ~4,0 Absorption rate = ,~-~'E) ~ g.p.d. Peroxide treatment (past 12 months) (Y/N) /~ ~ ~.~O,.,a.,,J If yes, give date ~/A 72-026 (Rev. 3/96)* EIF.T-STATIO N Manhole/Access (Y/N) .~P~el at* 'Pump off" level at* High w~ *Datum~'~'-'''~'~'~ C,.~cle~tested . E. SEPARATION DISTANCES S~ES FROM WELL ON LOT TO: Septic h/olding tank on Iot~ On adjacent lots Absorption field on 1et -~-~.-- ~~~4~~_ Public sewer main _ anout __ .~ service line Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation ~' / '~" Property line ~'/¥- Absorption field Water main/service line /'0 t.~ Surface water/drainage /0~/'~ Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line /O/+' Building foundation /0/Y- Water main/service lin /~ /'/- Surface water /00 l'/- Driveway, parking/vehicle storage area Curtain drain AJc~-/~_-- l~,JOt.~J~) Wells on adjacent lots ENGINEER'S CERTIFICATION2 I certify that I ha~ de,~mi..~hr~( field inspections and review of Municipal r,c~"~il}~,~;'~.'~i;b~ are ,nconforma th dellneslnefeotonthlsdate. Date i ~ HAAFee $ ~)D- Date of Payment Reoe,pt Number Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)* 7320 East Chester Heights Circle ~ Anchorage N Alaska 99504 Phone (907) 337-6179 ~ Fax (907) 338-3246 Consulting Engineers October 25, 1998 Gene Fowler C/O Prudential Vista Real Estate 4241 B Street Anchorage, Alaska 99503 Attn: Gloria Hoflich Subject: Septic System Adequacy Test. Lot 5, Circle. Bk 4, Greenbrook S/D. 6801 Teresa Dear Gloria: Per your request we performed an evaluation of the subject septic system. Our findings are summarized as follows: A. ADEQUACY TEST (10/23/98): The drainfieM is a 3.5 foot wide trench that is 50 feet long, and has an effective depth of 48 inches. Prior to starting the adequacy test, the monitoring tube was dry. Over a period of 2 hours, 1027 gallons was introduced, causing the liquid depth to rise to 37.5 inches, which corresponds to approximately 27.4 gallons per inch. The recovery was monitored 4 hours later and the level had dropped 24 inches, indicating an absorption of 658 gallons. Based upon this data, it was concluded that the absorption rate of the drainfield meets the Municipality of Anchorage requirements for a 3 bedroom house (450 gallons per day). NOTE: The adequacy of a septic system is influenced by numerous factors, including, but not limited to, seasonal surface water infiltration, groundwater variations, septic system maintenance (frequency of septic tank pumping, usage of biological additives), condition of drain pipe and pipe joints (which can be damaged by seismic activity and deteriorate with age), type of substances deposited in septic system (cigarette butts, sanitary napkins, misc. objects), and the amount of water being introduced on a continual basis. Consequently, the results of this adequacy test are only valid for the specific day of the test. Furthermore, because of the limited nature of this investigation, it is possible that there are hidden defects which may not have been detected. No warrantee is made regarding the future performance of this septic system. B. SEPTIC TANK: The septic tank was installed in 1982. It has two compartments, a capacity of 1000 gallons, and is made of steel. Steel septic tanks typically have a structural life of 20-25 years. No warranty is made regarding the life of the septic tank. Throughout the test it was noted that there was approximately 6 inches of liquid in the post septic tank clean-out. It is probable that the line at the outlet of the septic tank is separated from the tank and the pipe has settled. This condition does not appear to have adversely effected the operation of the septic system. If you have any quest Sincerely,, Je . ~ns, please contact me at 337-6179, or 244-9612. 3arness, P.E., M.S. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division .... 825 L Street. Room 502 · Anchorage. Alaska 99501 · (907) 343-4744 Health Authority Approval Checklist A. WELL DATA Well type ~ v resent (Y/N) Date completed Total ~ Cased to Casing height (above ground) Sanitary sea~ · '- . Wires properly protected (Y/N) Date of test . ~....FR~.~.~ AT INSPECTION Static.water level. _ Well production - WATER SAMPLE RESULTS: Nitrate Coliform . Date of sample: I~ B, or C, attach ADEC letter. ADEC water system number B. SEPTIC/HOLDING TANK DATA Collected by: Date installed ti / ~ ~''''' Tank size Foundation c e~tnout (Y/N) Y Depression (Y/N) Date of Pumping JO~;I./~ Pumper. A+ g.p.m. Numberof Compartments ~-- Cleanouts (Y/N) ~ High water alarm (Y/N) /d ~ C. ABSORPTION FIELD DATA Date installed I//~..* Soil rating (~e~:/ff2 or ffa/bdrm) ! / Length ' ~ Width ~..~ Gravel thickness below pipe Eff~tive absorption area ~OO Monitoring Tube present ~/N) y Depression over field ~) Date of adequacy test Io/~ Results (Pas~Fail) P~ For ~ bedrooms ' 10~7 (in.): Fluid dep~h~n absorption field before test (in.); ~ ~mmeaiately after gal water added Fluid dep[~ (ins)Minutes later: ~ ~orPtion rate= +~ * q.p.d, 72-026"er°xid' ,roatmen%2 months),/N)(Rev.,96,. ' ~ /''~ "~4N~ ~0' ~s' give date Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Parcel I.D. 017-431-12 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DVVELLING Expiration Date: 1. GENERAL INFORMATION Complete legal description GREENBROOK BLOCK 4, LOT 5 Location (site address) 6801 TERESA CIRCLE, ANCHORAGE, AK 99516 Current Property owner(s) JOERENE M HOUT Day phone Mailing address 6801 TERESA CIRCLE, ANCHORAGE, AK 99516 Lending agency Mailing address Day phone Real Estate Agent Mailing Address LES BAILEY & ASSOC. Day phone Unless otherwise requested, COSA will be held by DSD for pickup. NUMBER OF BEDROOMS: TYPE OF 'WA'~ER'SUPPLY: ~' Individual Well ;;.:'; - Individual Water :: , , . Stol'area Community ClaSs ~ Well PUbli~ Water System 3 TYPE OF WASTEWATER DISPOSAL: [] Individual On-site ~] [] Individual Holding Tank r-~ [] Community On-site E~] [] Public Sewer ['--] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. DSD SIGNATURE ~/"/ Approved for ~3 Disapproved. Oonditional approval for Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3792 Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date. 06/24/11 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorPtion rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteriStics, groundwater levels that may fluctUate dudng the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these vadous and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a ~ ~;_~,~i ~' system will function satisfactory for current or future ~'~ :: ~.'.;~:..~ ~, occupants or can ArcTerra guarantee that no unseen ~,~.,;~-~ ~ :. encroachments, deficiencies or discrepancies exist. ~ ~:.i ':... ::.~ ~."?~i ~ bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X '. 0N-SITE = · WASTEWATER . : Arsenic Adviso~ Maintenance Agreements Supplemental Engineer's Repod Other By: (Rev. 11105) Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: GREENBROOK BLOCK 4, LOT 5 A. WELL DATA Parcel ID: 017-431-12 Well type COMMUNITY - A IfA, B, or C provide PWSID # 2 1 0346 Well Log (Y/N) Date completed Sanitary seal (Y/N) Total depth ft. Cased to ft. FROM WELL LOG Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform colonies/100mL Nitrate Arsenic: __rng/I Date of sample: SEPTIC/HOLDING TANK DATA Wires properly protected (Y/N) Casing height (above ground) in. AT INSPECTION g.p.m, g.p.m. mg/L Collected by: Tank Type/Material Septic/Steel Date installed 6/22/11 Tank size 1000 gal. Number of Compartments _2 Cleanouts (Y/N) ~ Foundation cleanout (Y/N) ~ Depression over tank (Y/N) High water alarm (Y/N) N Date of pumping NA-NEW TAN~K Pumper C. ABSORPTION FIELD DATA Date installed 6/22~1 Soil rating. (g.p.d./ff~ or ~/bdrm) 1.2 Length 38 ft. Width --3 ff. Gravel below pipe 5.48 ff. Eft. absorption are~ 416 ~ Monitoring tube Y Date of adequacy test NA-NEW SYSTEM Fluid depth in absorption field before test __ in. Water added__ gal. Elapsed Time: __ min. Final fluid depth __ in. Absorption rate >= Any rejuvenation treatment (past 12 mo.) (YIN & type) _If yes, give date __ System type Deep Trench Total depth 11 ff. Depression over field N__ Results (Pass/Fail) __ For New depth __ bedrooms in. g.p.d. D= LIFT STATION Date installed "Pump on" level at __ Datum in. E. SEPARATION DISTANCES Size in gallons "Pump off" level at Cycles tested in. SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic service line Animal containment areas Manhole/Access (Y/N). High water alarm level at in. Meets alarm & drcuit requirements? On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation $% Property line 5'+ Water main 10'+ Water service line 10'+ Wells on adjacent lots 200'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation ;to'+ Water Service line ;to'+ Surface water ;tOO'+ Curtain drain 50'+ (None Known) COMMENTS Absorption fi.eld 5'+ Surface water ;tOO'+ Water main 10'+ Driveway, parking/vehicle storage 10'+ Wells on adjacent lots 200'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name KENNETH M. DIYFFETS Date 6/24/2011 COSA Fee $250.00 Date of Payment Receipt Number (Rev, 11/05) Waiver Fee $ Date of Payment Receipt Number CONSUL~I~ING, INC 212 E. 51a Ave, Anchorage, AK. 99503 Office (907) 868-3791, Fax (907) 868-3793 ]~ly l, 20:1.1 Mu.nicipai:tty of Anchorage 'Development Services 'Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot Line Waiver - Greenbrook Block 4, Lot 5 The asbuilt $'rtrvey conducted after construction of the new septic leach field wiflx a diverter valve to 'the existing leach field show the original line is approximately 8' from the property line. The new trench is iff from the property line. We are therefore requesting, a lot line waiver to 8' of property line be granted for future use of the original septic trench. W'e do not expect there to be any adverse effect on 'the subject or adjacent .lots by granting this waiver. If you have any questions, please contact me at 868-3792/FAX 868-3793. Respectfully submitted, ArcTerra Consulting, inc. Attachments: On-Site Inspection Repo:rt ~0/~0 39~d EBLE89SLOB g§:PI ~0~/~0/L0 Municipality of Anchorage P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 ,,http://www.muni.orfllOn$ite Development Services Department On-Site Water and Wastewater Proqram Department **** VARIANCE/WAIVER REVIEW **** WR#: 111141 HA#: 111218 Permit#: 111109 PID#: 017-431-12 Legal Description: Greenbrook Block-4 Lot-5 Engineer: ArcTerra Applicant: Joerene Hout Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 8.0 feet. This waiver approval applies to the existing absorption field to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Rec#: 7-1-11 Amount: $200.00 Date Paid: 7-5-11 **** VARIANCE/WAIVER REVIEW **** UNDER NO CIRCUMSTANCES SHOU~ AN AS-BUILT BE USED FOR CONS~UC~ON OR FOR ESTABLISHING BOUNDARY OR ~NCE UNES. ~E SUR~YOR TAKES RESPONSIBILI~ FOR ~E INI~AL ~ANSAC~ON ONLY AND ASSUMES FINANCIAL LIABIU~ ONLY FOR ~E COST OF ~E SUR~% LIS~D DISTANCES PREVAIL O~R SCALING. REPRODUC~ MAY CAUSE ERRORS IN SCALE. ~ cOT ~.~Y SURVEY TYPE SYMBOLS ~ nN~F~NOA~SmUC~REAS-~'LTAs-BU{LT " SET REBAR ~ ~ DRAINAGE~ ASPHALT O F~ND REBAR O C C WOOD ~NCE I:m::av:'~.l CONCRE~ PLOT P~N , . . AS-~UiLT , , , LOT ~R~Y . ~ AS-BUILT , , . N0 C~NERS ~T ~ RE~R~RCA~ AS-BUILT. , . NO C~$ ~T ASSUMED E~V. % ~ X METAL FENCE ~ WOOD 0ECK PLOT PLANS & LOT SURVEYS NOTE: IT IS THE RESPONSIBILITY OF THE BUILDER OR O~ER, PRIOR TO ONLY ~OSE IMPROVEMENTS ABO~ GROUND AND ~SIBLE ~LL BE CONS~UC~ON, TO ~RIFY PROPOSED BUILDING GRADE RELA~ SHO~. FENCES, ~LLS, SEP~C C~ANOUTS, SIDEWALKS. DRI~WA~, TO FINISHED ORADE ANO UTILITY CONNECTIONS AND TO DE~RMINE ETC., ARE SHO~ iN ~EIR APPROXlMA~ LOCA~ON, ONLY, SNOW ~E EXISTENCE OF ANY EASEMENTS, CO~NANTS OR RES~IC~ONS MAY PRE~NT SOME IMPRO~MENTS FROM BEING SEEN AND LOCA~D. ~ICH GO NOT APPEAR ON ~ RECORDED SUBDI~SION PLAT. ALL DISTANCES ARE RECORD UNLESS OTHERWISE NOTED. SURLY CERTIFiCATiON _~~, ~repored by Robert E. Johns, Jr. & Assoc. ~ ~x~ ............. ~ ~, ~ .~,~,~ ...... ~.~ ~... ~...~.~ Professional Land Surveyors ~ ~ ~ ~, ¢~ ~ t~ m* b~t ~¢ my ~ *~ ~7~'~ ~ORAGE, ALASKA 99504 ~ md ~ ~ ~* ..~ ~~ ~ ~~ Rec. Lot S.F. ~Rec. Plat File No. "~ ~ ......~~~~ ...... : ..th ., ~ ~ sc,~: 1" = 60' F~NDA~ON AS-BUILT ~. '"" ~. ,~ [. ~n~ ~.. ~y ~fy m~t ~ ~ ~ ~ ~ Date Surve~d: Drown b~ Checked b~ "~ ~ ' ~" ~'" ~'~~~= ~ ........ ~ 6/27/11 REJJMK FINAL S~UC~RE AS-BUILT Legol Description: ~ ~* Lot 5 Block 4