Loading...
HomeMy WebLinkAboutGREEN FOREST BLK 1 LT 1Onsite File r7reen Fores? Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 4 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191206 PID Number: 018-011-02 Dwelling: ❑t Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑■ Upgrade Name ABSORPTION FIELD I WEST/EAST SLAVIK LUND Deep Trench E] Wide Trench El Bed El Mound Site Address 12400 SILVER SPRUCE DRIVE *ANCHORAGE, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 907-227-0762 4 0.5 GPD/SF 11/11 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade SEE DWG. Ft. Gravel depth beneath pipe 7.56/7.48 Ft. Subdivision Block Lot GREEN FOREST; BLOCK 1, LOT 1 Fill added above original grade SEE DWG. Ft. Gravel length 40/40 Ft. Township Range Section N/A Gravel width 2.5 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 1200+ Ft2 2 **10+ Ft. Well *50'+ *50'+ *50'+ N/A N/A TANK X Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer INFILTRATOR Capacity 1060 Gal. Surface Water *50'+ *50'+ *50'+ N/A Material Number of compartments Lot Line 5'+ 10'+ 5'+ N/A NA HDPE 1 Foundation 10'+ 10'+ N/A LIFT STATION Manufacturer Capacity 110'+ 1 1 Remarks *CAT II AWWTS **SEE ATTACHED LETTER INFILTRATOR 540 Gal. Alarm location IN HOUSEt�rags• Electrical installed by K PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Installer KURT WHITTERS Drainfield D3034 CO/MTD3034 inspector DAVID GARNESS & TIM ECKLUND BENCH MARK (Assumed elevation) 100.00 ft Inspection1st 7/9/2019 7/10/2019 dates: Location and description 2�a 3'd 7/10/19 4117/11/19 BOTTOM OF TRIM AT SE CORNER ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Sta p Qo6op�0 Conditional Approval: Date 49 D p........................... .D .... ................. � Septic S Jr Garnes Q '. Q �Q4� Approved (ti Date` E-7 9 3 Note: this approval does not include well permit requirements. #AEcc884O000000 (Kev u5/u2/18) PERMIT NUMBER: PARCEL ID NUMBER: OSP191206 RECORD DRAWING 018-011-02 z - - - - - - - - - - - - - - �AOFFMAN - - - - - - - - - - - - - - - - - -------- ROAD I \ I A I B I C I \ FCO 19.6 6.0 35.4 BOTTOM OF TRENCH AND TOP OF I TANK INSPECTED BY MOA ONSITE EMPLOYEE TIM ECKLUND� I I I 21.7 25.4 17.3 FURROW CREEK; BLOCK 1, LOT 1 AWWU NEW IM -540 INFILTRATOR SEPTIC T\AXK NEW SINGLE COMPARTMENT IM -1061 INFILTRATOR SEPTIC TANK - z w 2 w 1n w 1- 0 DC01 I TE LOCATION OR DRAINFIELD BASED UPON MOA RECORDS AND EXISTING 4 BEDROOM ° HOUSE v B CO 10'+ 0 CO MT MT1 MH2 M 4 S o C SHED T a CO 10_+ I I GREEN FOREST; BLOCK 1, =LOT AWWU m CO cn x I � Q� J 10 n I C o Irn N - I U O J I � m I x w w O 3 z �I z w Im / C9 I I � I � T4 I EW DRAINFIEI D / I / I N CALE: I = n' GARNESS ENGINEERING GROUP, Ltd -- - ---�-- - ENGINEERING -- SALES? CONSULTING --- - 3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, AK 99507 -PHONE (907) 337.0179 -FAX (907) 338-3246' WEBSITE:-gamessengineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: SLAVIK LUND 907-227-0762 2 OF 4 LEGAL DESCRIPTION: DRAWN BY: GREEN FOREST; BLOCK 1, LOT 1 D.J.G. TYPE OF WORK: DATE: . SEPTIC SYSTEM RECORD DRAWINGS 7/19/2019 of AV ## i *• # .... 4 .......... 0 �. �...:..................... i 1 �^ •; Je re A.GGarness 4 = CE -7953 •; �_= LICENSE 14 OFIE ;'���•• #AECC884 / MT1 15.9 31.8 25.5 MT2 49.7 54.1 14.3 MT3 18.5 41.1 37.5 MT4 49.0 61.6 27.9 C01 13.4 30.0 27.1 CO2 52.1 52.6 17.0 CO3 1 18.5 1 41.8 39.8 C04 1 50.1 1 61.8 27.1 FS 1 29.6 1 42.1 18.4 FD 1 21.4 1 26.7 17.2 MH1 1 34.5 1 13.6 34.4 MH2 1 31.3 1 17.2 25.3 MH3 23.8 21.7 18.3 MH4 22.9 25.0 17.7 STI 37.0 18.7 31.6 DC01 34.6 17.8 28.8 I CO2 33.3 17.6 27.8 TMT C05 32.5 14.5 30.6 TANK INSPECTED BY MOA ONSITE EMPLOYEE TIM ECKLUND� I I I 21.7 25.4 17.3 FURROW CREEK; BLOCK 1, LOT 1 AWWU NEW IM -540 INFILTRATOR SEPTIC T\AXK NEW SINGLE COMPARTMENT IM -1061 INFILTRATOR SEPTIC TANK - z w 2 w 1n w 1- 0 DC01 I TE LOCATION OR DRAINFIELD BASED UPON MOA RECORDS AND EXISTING 4 BEDROOM ° HOUSE v B CO 10'+ 0 CO MT MT1 MH2 M 4 S o C SHED T a CO 10_+ I I GREEN FOREST; BLOCK 1, =LOT AWWU m CO cn x I � Q� J 10 n I C o Irn N - I U O J I � m I x w w O 3 z �I z w Im / C9 I I � I � T4 I EW DRAINFIEI D / I / I N CALE: I = n' GARNESS ENGINEERING GROUP, Ltd -- - ---�-- - ENGINEERING -- SALES? CONSULTING --- - 3701 E. TUDOR ROAD, SUITE 101 'ANCHORAGE, AK 99507 -PHONE (907) 337.0179 -FAX (907) 338-3246' WEBSITE:-gamessengineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: SLAVIK LUND 907-227-0762 2 OF 4 LEGAL DESCRIPTION: DRAWN BY: GREEN FOREST; BLOCK 1, LOT 1 D.J.G. TYPE OF WORK: DATE: . SEPTIC SYSTEM RECORD DRAWINGS 7/19/2019 of AV ## i *• # .... 4 .......... 0 �. �...:..................... i 1 �^ •; Je re A.GGarness 4 = CE -7953 •; �_= LICENSE 14 OFIE ;'���•• #AECC884 / PERMIT NUMBER: PARCEL ID NUMBER: ,OSP191206 RECORD DRAWING 018-011-02 WEST EAST TH MT CO FINAL GRADE = 98.62-99.37 MT CO FINAL GRADE = 98.75-99.34 TH ORIGINAL GRADE @ ORIGINAL GRADE @ HIGHEST POINT = 98.22 HIGHEST POINT = 98.54 FILTER FABRIC FILTER FABRIC e 'o °o o INVERT OF PIPE = 94.78 INVERT OF PIPE = 95.02 °o °o °o ' 7.56 FEET 7.48 FEET $ °0 0 s a BOTTOM OF BOTTOM OF TRENCH = 87.22 TRENCH = 87.54 ' � 0 10+ ° RELATIVE ELEVATION @ *SEE ATTACHED LETTER RELATIVE ELEVATION @ BOTTOM OF T.H. = 83.22 BOTTOM OF T.H. = 83.54 lkeVAo� .•'-�E OF 44 1� IIV ! GARNESS ENGINEERING GROUP, Ltd .... 9 ::.....4...... ................... CIVIL & ENVIRONMENTAL ENGINEERS _-- – —� 10 �� � 3701 E. TUDOR ROAD, SUITE 101 -ANCHORAGE, AK 99507 -PHONE (907) 337-6179 -FAX (907) 33&3246' WEBSITE: w. .gamessengineering.com � •• � ••••••• \ •,•.•, • •• .......... � PREPARED FOR: PHONE NUMBER: PAGE NUMBER: /� J Frei �A�Ga` nye S •� = SLAVIK LUND 907-227-0762 3 OF 4 �#G�J, PROJECT/LEGAL DESCRIPTION: DRAWN BY: •�♦��•. �� / `����� GREEN FOREST; BLOCK 1, LOT 1 D.J.G. 1� FQ�•'• • ....•• • '• *�, •� TYPE OF WORK: DATE: LICENSE FESS0't SEPTIC SYSTEM RECORD DRAWINGS 7/19/2019 #AECC884 1 ��°��� PERMIT NUMBER: OSP191206 PARCEL ID NUMBER: RECORD DRAWING 018-011-02 NAL GRADE = 96.89-96.98 STI TOP OF TANK AT INLET = 92.98 INVERT OF BUNG AT INLET = 92.50 1060 SINGLE -COMPARTMENT INFILTRATOR SEPTIC TANK FINAL GRADE = 96.80 TOP OF TANK AT INLET = 92.86-92.85 INVERT OF INLET BUNG = 92.16 IM -540 GALLON SINGLE COMPARTMENT INFILTRATOR TANK 2" HIGH DENSITY INSULATION (PER CONTRACTOR) — TOP OF TANK AT OUTLET = 92.99 INVERT OF BUNG AT OUTLET = 92.28 2" HIGH DENSITY INSULATION (PER CONTRACTOR) GARNESS_ ENGINEERING GROUP, Ltd ENGINEERING RA976SALESCONSULT ING NDOR ROAD, SUITE 101*ANCH 03 engneenn9.wm PREPARED FOR: PHONE NUMBER: PAGE NUMBER: SLAVIK LUND 907-227-0762 4 OF 4 LEGAL DESCRIPTION: DRAWN BY: GREEN FOREST; BLOCK1 , LOT 1 D.J.G. TYPE OF WORK: DATE: SEPTIC TANK PROFILE 7/17/2019 , • •,. / e re . Garn s �: •�# C 795 ' _= LICENSE '1� "ROFESS��+•♦ #AECC884 ri\\\\\ / MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) a43-7904 Fax: (907) 343-7997 hUp:/Aw^v.muni.or9/onsite Permit Number: OSP191206 Work Type: Septic Upgrade Tax Code Number: 01 801 1 02000 Site Legal Address: GREEN FOREST BLL 1 LT 1 G:2833 Site Mailing Address: 12400 SILVER SPRUCE DR, Anchorage Owner: ROHDE TROY A Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: 0 Disposal Field 10 Septic Tank 0 Holding Tank 11 Privy Effective Date mnlq� i Total Bedrooms: , I' �_n r , No Department 6/1912019 6/1812020 16604 f-1 Private Well n Water Storage 13 All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (1 8AAC72) and Drinking Water Regulations (1 8AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: The area where the drainfields are being proposed is currently a driveway/parking area. Prior to inspection report approval, the engineer shall confirm that the area has been modified so that it no longer Prior as a driveway/parking area. Z-11-7 Received By: Date: Issued By: Date: Municipality of Anchorage_ P.O. Box 196650 a 4700 Elmore Road Anchorage, Alaska 99519-6650 a (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section ,mcnr S• l)1; �1:11'CIII L'Ilt x x x x VARIANCE/WAIVER REVIEW X X X* Waiver#: OSV191043 COSA#: Permit#:OSP191206 PID#: 018-011-02 Legal Description: Green Forest Block 1 Lot 1 Engineer: Garness Engineering Group Applicant: Slavik Lund Your request for a waiver of the required 18.0 feet horizontal separation from the absorption field to the existing seepage pit has been approved. The approved separation distance is 10.0 feet. See engineer's waiver request for justifications. This waiver approval applies to the proposed absorption field only. ' Any fixture upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ................................................................ ■ ■ ........... ■ , Waiver is Granted: X Waiver is not Granted: Date: 9 / Approved by: Name of Reviewer ............................................... ■ ............................. ■ 1 **** VARIAN C E/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Fax: 907- 343-7997 On -Site Water & Wastewater Program Mayor Dan Sullivan On -Site Sewer/Well Permit Application . For A Single Family Dwelling Parcel I.D. 018-011-02 Property owner(s) SLAVIK LUND Mailing address 12400 SILVER SPRUCE DRIVE *ANCHORAGE, AK 99516 Site address 12400 SILVER SPRUCE DRIVE *ANCHORAGE, AK 99516 Legal description (Sub'd, Block & Lot) GREEN FOREST; BLOCK 1, LOT 1 Legal description (Township, Section & Range) Lot Size APPLICATION IS FOR: (® all that apply) Absorption Field Septic Tank Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Sq. Ft. Number of Bedrooms APPLICATION IS AN: Initial ❑ Upgrade Renewal ❑ Day phone 907-227-0762 4 THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR: TYPE OF DEWELLING: Single Family (SF) (w/wo ADU) Duplex (D) ❑ Multiple Dwellings ❑ (SF and/or D) WA by-"" +D fie_ .g&g& .&g&nl I Distance: � 12 I certify that the above information is correct. l further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP, Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: 5_46- Waiver Fees: a a Date of Payment: �Z20 %q Date of Payment: j /19 Receipt Number: Q3 ��? Receipt Number: Permit No. - 1 06 Waiver No. 05091 D `4 3 (Rev. 01/11) Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191206, Rebecca Carroll, 06/19/19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191206, Rebecca Carroll, 06/19/19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191206, Rebecca Carroll, 06/19/19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191206, Rebecca Carroll, 06/19/19 Carroll, Rebecca M. From: Jeff Garness <Jeff@garnessengineering.com> Sent: Tuesday, June 11, 2019 10:06 AM To: Carroll, Rebecca M. Cc: David Garness Subject: FW: 12400 Silver Spruce Dr - Sewer Attachments: Capture.JPG; 12400 Silver Spruce Dr - Sewer Main RD.tiff Follow Up Flag: Follow up Flag Status: Flagged Hello Becca. See the following input from AWWU regarding service to the subject property.....................................jeff From: Curtis, Nick J. <Nick.Curtis@awwu.biz> Sent: Tuesday, June 11, 2019 9:54 AM To: Jeff Garness <Jeff@garnessengineering.com> Subject: 12400 Silver Spruce Dr - Sewer Hi Jeff, I have attached a copy of the main line record drawing as well as a clip of our mapping system showing the general location of our mains. I have spoken with our engineering department to determine if this property is served by our city sewer system. They have determined that even though this property is fronted by a sewer main across Huffman, they will need a main line extension on Silver Spruce Dr if they would like service. Without the main line extension, this property is not considered served. If you have any questions, please let me know. Thank you, Nick Curtis Engineering Tech 11 Anchorage Water & Wastewater Utility Direct: 907-564-2708 Nick. Curtis(cDawwu. biz Excellence Through Innovation www.awwu.biz 1 Municipality of Anchorage Page I of '~, DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Name: ¢4 s, L ~ /~~ Wastewater System: D New ~Upgrade Address: /~ ~ ~~ ~~ ABSORPTION FIELD Phone: Nc. of ~drooms: ~ Deep Trench ~ Shallow Trench ~ Bed ~ Mound ~ Other LEGAL DESCRIPTION so, Rating: Total De~iginalgrade: GPD/Sq. Ft. Block: Subdiv~ion: Depth to pipe bottom from original grade: ~vel depth beneath pipe Township: Range: Section: Fill added above original g~ Gravel length: Ft. Ft. WELL: ~ New ~ U~ Graveiwid~ Number of [ines: Distance between lines: .~ Ft. Ft. Classification (Private, A,B,C): ~pth: Cased To: ~orption area: , Pipe material: ~, ~ )~ Ft. Ft. ~~ SO. Ft. ! Dat~%;d Driller: ' - Date Drilled: Static Water Level: Installer: ~ [ Pump Set at: Casing Height Above Ground: ~.~ ,~. ,t. TANK SEPARATION DISTANCES ~ s~ptic ~o~i~ ~ S.T.E.~. TO Septic Absorption Lift Holding Public/Private] Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines ~~ Material: Number of Compa~ments: Water /~ LineL°t / ~ /~ Size in gallons: ~H Foundation /~ ~ ~ "Pump on" level at: .... igh water alarm at: Cu~ainDrain ~ % /¢0 ~~ ~Electrical Inspections pedormed by: Remarks: ~tV~ ~CV~ ~S~d~ BENCH MARK Location and Description: Assume~ Bevation: Department of Health and Human Services approval Reviewed and approved by: ~ Date: ~ ~' ~ '"~. ~'~OrESS~O~'~'' · 72-013 (Rev. 9/91) MOA 25 ' , PERMIT NO: SW990208 P.I.D. NO: 018-011-02 AS-SUILT WASTEWATER ABSORPTIBN SYSTEM LOT1, BLOCK 1 GREEN FOREST S/I) EX]ST'G SEPTIC TO BE REUS NEW 3000g HOLDING TANK ALARM SYSTE~ EXIST'G CRID Tn 'RE SWING TIES CO A B DV 10.0 6,B CI 9.3 7.5 ET B.5 ED 5.7 17,8 EC 19.9 34.7 CP 12.4 6.8 C3 14.6 10.8 C4 17,5 17.3 C5 EO,3 21,5 C:\kVork\2-1SPRNG,DWG HUFFMAN 94,83 96,36 J TH 1 ]9'O0"E DESIGNI PERC RATE: 75 MIN/IN NOT SUITABLE FOR SOIL ABSORPTION SYSTEM, HOLDING TANK - 30009. 87' BURIAL DEPTH TD TOP. 96,36 31_ 98.2 NH~D ~OGOO?ANK I4'7 TANK SECTIBN PREPAREI) FOR: Ms. Lynn Kenney-Owner Mr. Gtenn Hugh~on-Agen~ C/o Dalt Reat~y 555 W. Northern Lights Anchorage, AK 99507 (907) 844-5559 PANNONE ENG, SVC P. D, BOX 102954 ANCHORAGE, ALASKA 99510 278-88t8 Phone & F(lx DATE: 7-28-99 AS-BUILT SCALD 1'=50' MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Serv/ces Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (9O7) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Jul 20, 1999 Expiration Date: Jul 19, 2000 Permit Number: SW990208 Legal Description: GREEN FOREST BLK 1 LT 1 Design Engineer: 0062 Pannone Engineering Services Owner Name: Lynn Kenny Owner Address: 12400 SILVER SPRUCE DRIVE ANCHORAGE , AK 99516-2601 Parcel ID: 018-011-02 Site Address: 012400 SILVER SPRUCE DR Lot Size: 18000 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Steven R. Pannone, P.E. Consulting Engineer (907) 272-8218 P.O. Box 142025 Al~chorage, Alaska, 995 I4 (907)272-8218 Fax July 11, 1999 Municipalily of Anchorage Dept. of Health & Human Services On-Site SmMces Section P. O. Box 196650 Anchorage, Alaska 99519 Sllbject: Lot I, Block 1 Green Forest Subdivision, Septic System Upgrade Permit Request Ladies and Geutlemeu: My finn was contacted to design and install a replacement septic system for tile referenced lot. The existing draiufield is in failure. 1 conducted a field investigation to locate existing wells and septic system as well as a record search before designing the proposed system. We conducted a soils investigation in the most likely location for a replacement system. The soils were tight silts, with a percolation rate of greater than 60 minutes per inch (see the attached soils log and percolationtest). I propose installing a 3000-gallon holding tank on the referenced lot. The holding tank will have an almm system, as well as a concrete balast mat to prevent the tank ii'om floating. The lot is approximately 18,000 sqaare feet in size. Lot 1 slopes to the west at a rate of approximately 3 to 5 percent. The proposed holding tank installation will be located in the eastern portion of the lot on a relatively flat area south of the existing house. There will be easy access to the tank for pumping tracks. Tile proposed location is greater than 75 feet away fi'om any wells. The proposed system will be greater than I0 feet from tile water service lines. The proposed installation will not affect the fi~ture development of the sun'ounding or existing lots. See the attached design. Please contact me at 272-8218 or 22%3522 if yon have any questions about the proposed installation. Sincerely, Attaclunents: C:\WORK\I- [ (}RI~]£NI:ORI,:ST 00 I.t)()C PERMIT NO, SW P.I.D. NO: 018-011-02 DESIGN WASTEWATER ABSBRPTION SYSTEM LOT1, BLOCK 1 GREEN FOREST S/D HUFFNAN EXIS1G EXIS 10009 SEPTIC TO BE A IN PL EXIST'G CRI3 ABANDBN IN PL C:\V/ork\2-1SPRNG.DWG 94,83 EXlST'G WELL'~'-o ~~ F3 - 5 0% TH 1 39'O0"E PREPARED FBR: Mr, Glenn Hugh~on C/o D~ Rea[¢y 555 ~. Northern Lights Anchorage, AK 99507 (907) 244-5559 WELL'~-o ~ Ld PROPOS/ED o ING TANK ALARM SYSTEM,° ? DESIGN: .... ~6,3~ PERC RATE, 75 MIN/IN NOT SUITABLE FOR SOIL ABSORPTION SYSTEM. HOLDING TANK - 30000. 87" BURIAL DEPTH TO TOP. PANNONE ENG. SVC P. 0. BOX 102954 ANCHORAGE, ALASKA 99510 272-8218 Phone & Fax BATE, 7-13-99 [ DESIGN SCALE: 1':50' I PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: / -/ ¢ 12LaT~/L,/ F'o/z~._??- Township, Range, Section: 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O 1 2 3 4 SLOPE WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? '~ P E Oeplh Io Water After . Monitoring? T~ VL'T' Date: SITE PLAN Reading Date Gross Net Depth tm'c~ Net Time Time Water Drop PERCOLATION RATE ~ ¢~ tm,nutes/,nch) PERC HOLE DIAMETER TEST RUN BETWEEN dO FT AND "~ F7 , '~ CERTIFY TH~NT T/HIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 'f~///~/4'~¢ 72-008 (Rev. 4/85) Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 Certificate of On -Site Systems Approval Parcel I.D.018-011-02 Expiration Date: 10-26`1 1. GENERAL INFORMATION: Complete legal description Green Forest; Block 1, Lot 1 Location (site address) 12400 Silver Spruce Drive *Anchorage, AK Current Property owner(s) Slavik Lund Day phone 907-227-0762 Mailing address Real Estate Agent 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ i �� YNaiver Fee $ Date of Payment ��o'���1 q Zq� Date of Payment Receipt Number ®a(QZ5_6 # Receipt Number COSA # QJC Lql 39 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Garness Engineering Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 Engineer's Printed Name: Jeffrey A. Garness Date: ' ( C) F In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in accordance with the guidelines and regulations established by the Municipality of Anchorage and 00000 00 industry practices. The reported results describe the condition of the system/s on the date/s of the evaluation. Separation distances were measured to readily identifiable features. Hidden defects or ` 7 encroachments may exist that were not identified during the evaluation. The operational life of all wells S and septic systems depend upon a variety of variables, including but not limited to, soil conditions, of groundwater levels (that may fluctuate during the year), quality of construction (materials and0� L T workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and • • • • . • • • • • • • • • • • • • • • • • . • • • are outside the control of GEG. Satisfactory test results do not guarantee future performance of the , system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of ` the well or septic system. GEG makes no representation whether an alternative well or septic system. � rr�'ess;• ... can be installed on the property in the event either of the current systems fail to perform adequately in �00 9 I . yC —791 3 �� G the future. The content of this report is for the sole benefit of the person/party that retained GEG to perform the evaluation. Reliance upon the information provided in this report by any other person or party (including subsequent property purchasers) is not authorized, nor will it confer any legal right �Qea pyo f e ssio^°oma whatsoever. �fHCl.l.25t54 6. DSD SIGNATURE K System #1 Approved for -t(— bedrooms By: System #2 Approved for bedrooms Isapprove Conditional approval for bedrooms, (OF�t 6� with t llowi VV A- ffatioi v WATER AND Q PR(_)( -,P AiVi 6 JJJJ�O.O C`� "NTSFR�►�,L Original Certificate Date: 7 2L l The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: -- COSA Checklist Nitrate Advisory r Septic System Advisory Arsenic Advisory Well Flow Advisory Other Legal Description: GREEN FOREST; BLOCK 1, LOT 1 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled UNK Total depth 98.7+ ft Cased to UNK ft FOR Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) 12+ in. Date of flow test for COSA 41512019 Static water level at beginning of test 41.8 ft. Comments B. TANK DATA Age of tank(S) NEW years Tank type/material HDPE Measured operating fluid level in septic tank NEW ❑ Standpipes/foundation cleanout per record drawing Date of pumping N/A D. ABSORPTION FIELD DATA NEW Which system tested (date installed) 7i2019 ❑ ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade * ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of effective. If not, state depth into effective - Parcel ID: 018-011-02 Structure served by this system Well production at time of test 4.8+ gpm Water storage tank volume N/A gallons Well disinfected for coliform test? ❑ Yes BE No FOR Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic 22.7 ug/L ❑ Arsenic less than MRL (ND) Collected by GEG Date of Sample 4/16/19 C. LIFT STATION ❑ Required maintenance completed Age of lift station NEW years Lift station material NEW Comments: N/A Adequacy test date N/A Results ❑ Pass For 4 bedrooms Fluid depth prior to test - in Water added gal New depth in Elapsed time - min ❑ Code -required soil cover over field Final fluid depth - in ❑ System presoaked Absorption rate 600+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencies: 'SEE RECORD DRAWINGS COSA Checklist yellow sheet 0 e E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ✓v Yes *50+ Community Sewer Manhole/Cleanout > 100' ** 45 ❑ Yes if No ft ❑ Yes if No ft Neighboring Tank > 100' M Yes if No ft Private Sewer/Septic Line > 25'E] Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No *50+ ft Holding Tank > 100' ❑✓ Yes if No ft Neighboring Absorption Fields > 100' Surface Water > 100' ❑ Animal Containment > 50' ❑✓ Yes if No ft M Yes if No ft **45 Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' [:]Yes if No ft ❑✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ✓0 Yes if No ft Surface Water > 100' ❑ Yes if No *50+ ft Property Line > 5' ✓v Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ✓❑ Yes if No ft Private Wells > 100' ❑ Yes if No *50+ ft Water Main > 10'✓❑ Yes if No ft Community Wells > 200'✓0 Yes if No ft Water Service Line > 10' ❑✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10'✓❑ Yes if No ft Private Wells > 100' ❑ Yes if No *50+ ft Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' ❑✓ Yes if No ft Surface Water > 100' ❑ Yes if No *50+ ft F. ENGINEER'S COMMENTS *ADVANCED WASTEWATER TREATMENT SYSTEM **SEE ATTACHED RECORD DRAWING FROM AWWU WHICH SHOWS ALL JOINTS WERE "HEAT SHRINK (SEAL ALL JOINTS)" G. ENGINEER'S CERTIFICATION _ 1 certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with p C'D 4T MOA COSA guidelines in effect on this date. 0, :., i ..... ... .f r Garn ss,: 00 9 CE—` (3 c�G 4p r �1 �� G•'t�3 ��AO COSA Checklist yellow sheetrooms #AECC884 ofess* ��0000�� Arsenic Advisory Certificate of On -Site Systems Approval #OSC191334 Subdivision:Green Forest,Block, 1 Lot 1 A water sample revealed an arsenic concentration of 22.7 micrograms per liter (ug/L). The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 ug/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. information on arsenic is available from the On -Site Water and Wastewater Program website (www.muni.org/onsite) or at 343-7904. _ This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. Municipality of Anchorage P.O. Box 196650 a 4700 Elmore Road Anchorage, Alaska 99519-6650 a (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section .�»cnr S• l Department III * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV191043 COSA#: Permit#:OSP191206 PID#: 018-011-02 Legal Description: Green Forest Block 1 Lot 1 Engineer: Garness Engineering Group Applicant: Slavik Lund Your request for a waiver of the required 18.0 feet horizontal separation from the absorption field to the existing seepage pit has been approved. The approved separation distance is 10.0 feet. See engineer' waiver request for justificatio s. Vl acv,¢ r - f o f ce e6-� � � bel,- t v� � Ajarwme d 4-& Ise i d This waiver approval applies to the proposed absorption field only.' Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ............................................... ■ ............................. ■ I Waiver is Granted: X Waiver is not Granted: Date: (p 9 9 Approved by: Name of Reviewer ................ a .............................. ■ ............................. ■ t **** VARIAN C E/WAIVER REVIEW **** RECORD DRAWING KADREflT Ilrfl.• �CfMt TyM` — 502f�1(tlOEllT m.CRBtiyLF11afRF oe�An:➢LfL IO(Y . r..IT/nnl A rrAlwr�o�ar Arr.rr Wr�.Y•y�•Ay.+Mr �TJAYE-SyARY<iRpY:y •191.67 (17'IP) "-191.58 (12'm) I $T :100+00.00 / CONNECT TO OLE dRIAI=205.68 (NOT CORE DRILLED) J -t n ora✓/ Z ................. +�' , .JS ........�.. L I 00 50+00 125.2' 100' PRIVATES 12, N V D. 11 (TYPE A)\ � �� � WAN3 ROAD N mSTATE _.' S� W GRAPHIC SCALE N Z g4TTACIW[NT a 7 Q - S2 19., YEAR ALASKA 2010 PR04CT —A -N --STP- -1)/539: ADceNw N flCV1—S No. oAT[ RAW( ® 12/8/11 RECDRD Np DnAWN9$ llnnlqu ANO F1 Uf; SMITH t—�•—+ -• a —a——a—,.+— BEFORE YOU DIG -- -r-INSTALL EN CLOSED INVERTS PER SSATH 12�T.o _ - -r -ROW-- CALL FOR FREE BSE PLAN DETAIL SHEET S5 NI T _ 1 c '1, UNDERGROUND I ! 2 3 51 i �1 LOCATION LAKE OTIS PARKWAY NORI.!'RN HAWN, w SILVER __. SPRUCE DR__ MEANDER OR LANDKARK 51 MACE ST ....:....'//.....:....:.NOTE...:....:........ a�1t4FK.1j1i ..:. : �,BEDOING IS "C" FILTER 205 ROCK BELOW. k ABOVE 8 PIPE -� �... .....;.... TI .. .. .. ........ ..... .... :..... ... .; .:.. 200 PLANS DEVCLOPED BY:`DOWL NKM 1.1 ..... ................. a..wtw•v•nus•o«s.lrox HEAT SHRINK ® .....; ... E.1....; ...,_ .........; ....:.. _ ;. . ...; . 195 HUFFMAN ROAD I: —`"_"(SEAL ALL JOINTS) ... . RUCTION OLD SEWARD HWY TO ....:....�rl ............ ........................ .. . LAKE 0715 PRWY 1D6.55 LF: 8* DIP CL50.0 0:40X: : 41.84. LF 81 DIP CL50'O U.40X�:' ,_,��� SEWER PLAN AND PROFILE ROFI 100.00 101.00 1(12.00 190 STA 100.00.00 TO STA 101.98.39 GARNESS ENGINEERING GROUP, Ltd --== ENGINEERING > SALES-, CONSULTING r----= July 1911, 2019 Municipality of Anchorage Development Service Department On -Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 Ref: Waiver request for Green Forest; Block 1, Lot 1 To whom it may concern: QuardicS, Advanced T c.3bncvlt System D - - The new septic system was installed on 7/9-11/2019. During the installation, the new dual trench type drainfields were installed 104 apart. Per MOA onsite code, the drainfield should be installed a minimum of 10'+ or twice the effective depth. We are requesting that your department issue a variance and allow the drainfield to remain in place and add the new "waiver" to the existing waiver from new drainfield to the existing seepage pit (OSV191043). Justification for granting this wavier is as follows: • The new drainfields receive CAT II effluent • Per the T.H. and percolation test in MOA records, the soils percolated at 69 minutes/inch. Our design proposed an application rating of 0.5 gpd/ft2. This is conservative as the absorption rate is on the "lower/faster" end of the spectrum which applies for soils up to 90 min/inch. • There is a reserve site and flow diverter for the drainfield • The old seepage pit is surcharged and during the excavation of the septic tanks, no effluent was noted weeping into the excavated area, which was less than 10' from the surcharged seepage pit. In short, it is reasonable to believe that there will be minimal hydraulic connectivity between the two new trenches. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. A Sincerely, a� 3701 East Tudor Road, Suite 101 "Anchorage, Alaska 99507-1259 Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this I � Day of 64 M of 20] 41, by and between Q&OCK' ck i erk-- Vli 1I MNerein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as located at (legal description) ; LT I 2. Maintenance, Repairs and Alterations. (Owner is required to read, understand and initial each section) Ihroughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This l includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. vo Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. n_W Owner agrees that any sale or transfer of title of the property will not occur without a new CCertificate of On -Site Systems Approval. �113 Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. ' Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the -Agreement -or -any -part hereof, or the right of the Municipality-- -- thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: By:&_k_W4 (signature) Date: lDebi� i I r'cKh A�a b!u"N (print name) STATE OF ALASKA ) ss. THIRD JUDICIAL DISTRICT ) The foregoing i strument waA acknowledged before me this ]L day of 20/(, by &OZ], MKS NOTARY PUBLI FOR ALAS My Commission expires: Brophy l ne t4, 2023 MUNICIPALITY: By: (signature) (print name) Date: [zl� j Title: (rev. 05/18/2018) Page 3 of 3 woa•sAanmva!lua;•Mmm warsAanJnsiapua;vu 1V35lVNOISS3dOHd of u! - gggi'09vi o6 '•.13 an mg 8I566 eNsely'aaejo43uV 3 aenS •anV gl8S'M 059 1tlNof l! 2i3IJINOWJ ill 'sAanzns zapuaj _� Q ' � ,nC.• 6TOZ/zz/L '620Z'yl9i Alnl' uo uo!s!nLadns 3aaA!p Aw japun uo'aw Aq pawoyad seMA;?NnS uogoadsul a0e5>JOIN s!yl leyl A;!Uaa Agalay !Jau9eM mapwj q ••, �i' ;- n w nn°o 1 �O� a '. T 'oN iiun uoiSlAipgnS lsajoj uaaaJ T*)01S 1101 ,fanin5•zltn8-SV i •' ••Hl(7V i �/� b• , ,•' 'au!1 muaJ:o Nepunoq a 6u;ys!lgels—j io uopgMsum 1qJ pasn agluawroop s!gl pineys srue;swmL!o ou lapun leld p,mai agl uo Jeadde ou op gpl4mu0!P!JISaLJo's7ueuanm'sluaw2sea Aue Jo muals!xa •' d R41 Au!W12jap o7 j-0 a4I Lo A!I'gsuodsw aql s! 11 }canal Asw Aanms /aepuroq wanbasgns a lewne <II salooew Aue of loolgns el We An ns kepumq a a;n;!lsum lou scop luawmop s!41'Aanms eql Jojowq o4l le suo!IFum L `S • • JL L bT b ay: pue sivawa—dw7 a1q!rn siuosadai Aanms aqy -sp,.pue;S uopeool a5e6;LOL7 S'IdSV .4141..' sa!;dwm A—S s!ql I I I snuptmd aye sau!! Auadad of suo!sUaW!p IIH'b ,aaj UI moos 1 luudloo; Suippnq wamddellens!n a4i 01 we sreglasMuawamseaw IIV'C -Farms s.ql 6uueda,d Jo Ism a41 pamxa Jou pegs Aa—S Slgi,o, A7!I;geg agl'mua5:182u S-5wJ 6uildmx3'Z 'smel 3g6uAd.3 !wapaj of Pa!gns s! pue:uopoesueil Ayadoid el6ws a /o aMo d q),o/ palean s! luawna-lp s!y1 L 09 Oc 9l 0 saloN lemu-V 4anogvIuel os�-� 41163n Peay,an0 =no— xogpeAl3� IlaM ua3epA iN1) ogda5 (S. 1 u9!S lawls �__ aauaj -o-- r3a0 ® uazavv seg alanuog clod auoydala.L rly JaMod ap!slnppalap4 3uloa13 ' 1 Zlo7 " C6'D6 3.00 6S .66N 9 oa i5s ±' 03HS a 03HS W L 9'41 ¢ 0'B M1 'J�VINtlVd +�L'ZL S I 0 73 YN0 i ( w Iwo i a o$ 0 L 101 W sr e'rz' y 1 Al 0 a o'sz iM, tyI CB'bb 3. t ' 1 ----- �J------- OdOLI N V/N :P!A9 b£I-99:Ie!d 610Z/91/L0:a;e f I I \ fi\-0 a o$ / `i egozou3 nap :AS pa.19pap J loafojA in'sAanznc ianunu A! MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519~6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING. GENERAL INFORMATION Complete legal description Location (site address or directions) Property owner · Mailing addres~ Day phone Lending agency Mailin. g address Day phone Agent ~B. ~ L-~ ¢uqP-z--o~v Day phone '~4'~-~._~;~-9. Address '-S'.--%S- ~¢~% ,u, oa--ct~.~,¢t4/C--cj '-8, c,4b: A~oI~- 'A ~ ~¢,..¢~ Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev, 1/91) Front MOA~21 5. STATEMENT OF ~ INSPECTION BY'ENGINEER= i~ : ' : · -:~ ' As certified by mYi~al~ affixed h~ret~ and ~s of the Validation date shown below, I verify that my investigation of this Health Authority Approval application shows that th'e on-site water supply and/or wastew,~ter disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further Verify that based on the information obtained from the Municipality of AnchOrage files and from my investigatio~ and inspection, the on-site water supply and~°r wastewater dispOSal' system is in .compliance with all Municipal and State codes, ordinances, and regu. lations in effect On the date of this insPection. Phone DHHS SIGNATURE "/ ApProved forbedrooms. Disapproved. Conditional approval for Date ?'E'o -7-~- E · bedrooms with the following stipulations: Additional Comments By: Date The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in'paragrap'h~5-above by an_independent · professional engineer registered in the State of Alaska. The DHHS does this as a couAesyto purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements, Employees of DHHS do not conduct inspections or,ana!yze.da,ta .bef,.o..re.a !;erfifica,te is issued~.,The Municipality of ,Aqchorage. is not responsible fo~: errors 0~; OmiSSions in'the pro!. ,e~?!~na!.?gine~r'~. ~o~k..: i:-.,.,"~:. ~ '.. ' , ' ~' ~-~,.~ ~ ~oX~' ..... : - . _...-. . . D. LIFT STATION Date installed Manhole/Access (Y/N) High water alarm level at* SEPARATION DISTANCES Size in gallons uat*eC6T~~'-~ off" level at* "Pump m SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot On adjacent lots On adjacent lots Public sewer main Sewer/septic service line /c~¢--t- Public sewer manhole/cleanout ,' c,¢ '~ Lift station / c~'~- SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation P,- /¢,~ Property line /~-' Absorption field /c~ Water main/se~ice line ~' Sudace water/drainage '~ ~ Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line Surface water Curtain drain Building foundation / C~ ~ Water main/service line DriveWay, parking/vehicle storage area ~--(:~ Wells on adjacent lots ENGINEER'S CERTIFICATION .,.. .... .. /certify that/have determined thru field inspections and review of Municipal recor~C~l~ 'C ::,~'e~'~*~ -- in conformance with MOA HAA guidelines in effect on this date. ~~.~7;:,,,~,,~. · ;. Signature- ~ Engineei's Name ..~'7'-c.-.-~ ~,,j,x. jc,~r'~ Date '7¢/"~ ~/¢/~'~' HAA Fee $ ~,f'~('l. ¢')U Waiver Fee $ Date of Payment ~'/- ,.C~. OL~ Date of Payment Receipt Number ~:~'~'~\ 4' '~O ..~ ~' ~) ' '' r ~ ~ R~%iptNumber 72-026 (Rev. 3/96)* Municipality of Anchorage R E C E !~--~ DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division JUL 2. 6 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 34~i~r~4,,4-alily-.v,, Dept. Health of 4,,rn~,Anch~r_ag.e Health Authority Approval Checklist & I_....,~,, ~erv~ces Legal Description: Parcel I.D.: O/,¢~'- ~/1~0'"~ A, WELL DATA Well type Log present (Y/N) ~ ~ Date completed Total depth ~ ~,,,u' ouur'~' Cased to Sanitary seal (Y/N) IfA, B, or C, attach ADEC letter. ADEC water system number Casing height (above ground) Wires properly protected (Y/N) Date of test Static water level Well production FROM WELL LOG AT INSPECTION ~/~ { ~ ~ g.p.m. /-4. ~ g.p.m. WATER SAMPLE RESULTS: Coliform ~-' ~ ~ Nitrate ~)' ''~-' (-~ Other bacteria Date of sample: '7-/"21 / ~ ~' Collected by: ~ ,[2 '~:~wa)o,] t~' B. SEPTIC/HOLDING.TANK DATA~ ~m~ ~¢7 ~ ~,F,~. A~uAc o~ ~ ~w~. ~te install~ TM/~ / ~ Tank size 1~o Number of Compadments ( Cleanouts Foundation cleanout (Y/N) ~ Depression (Y/N) ~ High water alarm (Y/N) Date of Pumping ~[~L[q~ Pumper ~% ~t&T,~% ~~tt~ ~~t~ ~,~h. C. ABSORPTION FIELD DATA ~ ~ ~ ~t~ ~ ~ ~ ~~, ~H~ ~> Date installed ~/~ / ~ Soil rating (g.p.d./~2 or ft2/bdrm) ~ ~ System type Length /~ r Width / b ~ Effective absorption area :~'c¢__ ~ Date of adequacy test ,5-/ /&'--/ q, ? Fluid depth in absorption field before test (in.); ct ~ Gravel thickness below pipe Total depth /-5"- / Mon tot ng Tube present (Y/N). t Depression over field (Y/N) Results (Pass/Fail) ~'r,k ~(- For ~ bedrooms Immediately after ~ gal. water added (in.): Fluid depth (ins) Minutes later:. Absorption rate g.p.d. Peroxide treatment (past 12 months) (Y/N) .~ If yes, give date 72-026 (Rev. 3/96)* ~615301 T-223 P.O~/03 F-g~4 CT&E Client Name P~oJ~ Nal~e/~ Client Smnpl~ Or~er~ By To,ut KoLif~rm O.SO0 u 0,§00 Client PO~ PHaI~d Date/Time 07127/9~ 12:36 Co]le¢l~ Dnte/Tt~ 07/21/09 18:00 ]Received Date/Tl~e 0~/')2199 10:30 Teehlll~ll Director: Stephen C, EPA 300,0 O?72Z/~ 10 ma~ 07t~2/~ 07/22/~ GAAB-HD I GC~ ~,TER ANCHORAGE AREA BORC .... H HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION LEGAL DESCRIPTION~. ~z~?~:°-//.._~-.~(~'.:. d~Zf~4././~4r~/: SEPTIC TANK: DISTANCE FROM WELL LIQUID CAPACITY / MATERIAL " .- . NUMBER OF '~--~'~f'~ ~--~ COMPARTMENTS GALLONS. INSIDE LENGTH ;~ ~/~INSIDE WIDTH ~ LIQUID DEPTH .... SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS / OUTSIDE DIAMETER ~ OR WIDTH // LINING MATERIAL__c'~I~-c~./2 (Z~'d~J~'~- ~-~/~'?~J' DISTANCE FROM WELL / NEAREST LOT tINE totAL EFFECTIVE ABSORPTION AREA (WALL AREAl LENGTH ,/.dx> .*' , , DEPTH BUILDING FOUNDATION ?u/'~) ~'~"-' SQ. Ft. TILE DRAIN FIELD: DISTANCE FROM WELL ~_.~.~.~'~-"~"4~FOU~ATION_ , NEAREST LOT LINE NUMBER OF LINES..../"' DISTANCE BE:EEN LI~ ABSORPTIO~A SQ. FT. TOTAL LENGTH OF LINES IN. TOTAL EFFECTIVE DEPTH: TOP OF TILE TO 'FINISH GRADE DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL: TYPE.~._'/~J/~/~"~~°, DEPTH ~".~ x NEAREST .~ SEPTIC LOT LINE ~' / ~ , SEWER LINE ,TANK DISTANCE FROM / WATER , BUILDING FOUNDATION..~- ~ ?L~ SAMPLE ./~/'~'~ , NEAREST , SYSTEM , CESSPOOL '-~ , SOURCES .... DIAGRAM OF SYSTEM ~. 6 2~' ~<-/x~'~-' DISTANCES: GAAB-HD-2 GREATE 327 Eagle St. ANCHORAGE AREA HEALTtI DEPARTMENT Anchorage, Alaska 99501 )ROUGH 279-2511 Case No. _.~ ~' SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT RESIDENCE ADDRESS LEGAL DESCRIPTION APPI_ICATIONTO INSTALL: SEPTIC TANK ~' ,SEEPAGE PIT ~ ,DRAIN FIELD TO SERVE THE FOLLOWING FACILITY PERCOLATION TEST RESULTS ANTICIPATED DATE OF COMPLETION MAILING ADDRESS ?~'0,2. ~z,e,,-,,..~,..~. PHONE NO.? LOCAT,ON OF INSTALLAT,ON ,OTHER_ BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT THIS IS TO SERVE AS /'/~c/~ /~:~,-.c~r' , PERMIT TO INSTALL A AS DESCRIBED BELOW. SIZE OF UNIT TO BE SERVED SEPTIC TANK SIZE "Tff-d~ TYPE ..~/e~._~ _SEEPAGE AREA DISTANCES: I certify that I am familiar with the requkements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above ~gsc~ibed system is in accordance with said code. ~o~-t~.g~c~ ,, ,~ ' . ,~ '~ ~'. ,; , DATE. ~ APPLICANTS SIGNATURE