HomeMy WebLinkAboutGREEN FOREST BLK 2 LT 7Onsite File Green Forest Block 2 Lot 7 #018-011-10 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191138 PID Number: 018-011-10 Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade Name CANDIE CARAWAY ABSORPTION FIELD - EXISTING ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 12401 SILVER SPRUCE DRIVE ❑ Other Phone7Number of Bedrooms Soil Rating Total depth from original grade 3 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot GREEN FOREST 2 7 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft2 Ft. Well 100'+ -- 25'+ TANK ® Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer GREER - DEEP BURIAL Capacity 1000 Gal. Surface Water 100'+ -- Material STEEL — 10' MAX DEPTH Number of compartments 2 Lot Line 10'+ __ NA Foundation rj'+ ILIFT STATION Manufacturer Capacity Gal. Remarks TANK INSTALLED PER PAST MOA CODE EXISTING WELL ON SITE WAS DECOMMISSIONED Alarm location Electrical installed by Installer OWNER PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield Drainfield CO/MT 3034 Inspector FWC BENCH MARK (Assumed elevation) 100 ft Inspection 15c 11/19/20Location dates: 2"d 11/220/20 and description 3rd 4'h BOTTOM OF SIDING ON-SITE WATER AND WASTEWATER SECTION APPROVAL OFA "�`. • "' Conditional Approval: Date •'' �'�ll� .. 4..- ....... 0 •'•' '•"••••••/ •Curtis Septic System Approved -,� !�''p�%p,� Date � 42� Huffman •: � � � F••, CE 128991 c���'•.8/1/22 ,.•'.��� �k`, �P\R\OF�ES~S�OV� Note: this approval does not include well permit requirements. kmev voiuu j0) PID:018-011-10 PERMIT:OSP191138 CANDIE CARAWAY GREEN FOREST B2, L7 FIRST WATER CONSULTING MUNICIPALITY 907-343-7904 l?FVE .i)PMENI� SERVt�t S Dt 1'ARTM �iT ,� Fax: 343-7997 on -Site Water and Wastewater Section www,rnuni_orgloosite Well Decommissionin d a m A Legat Address: Block 9— LOt �— SUbdlviston ^� T R Section Lot cm siteWater S wastewater section certified contractor performing the well decommissioning: Signature: company: r .. Method of decommissioning: AMC 15.55.06ou a. Welt decommissioning date — � -- Location: Use the space 6etow to provide a drawing of the property showing the following Items: Horth arrow Decommissioned well locatlon t-ocation of other water wells on the property Two separate swing tle distances for each well shown on the drawing Note: The awing-tle distances shall be ttteasured from either permanent structures or the property corners. and FIT form.doc Carroll, Rebecca M. From: Sent: To: Subject: Correct. Becca Carroll Onsite Water and Wastewater Municipality of Anchorage 343-7908 Carroll, Rebecca M. Wednesday, April 15, 2020 11:28 AM Brent Western RE: GREEN FOREST BLK 2 LT 7 From: Brent Western <firstwaterak@gmail.com> Sent: Wednesday, April 15, 2020 11:26 AM To: Carroll, Rebecca M.<rebecca.carroll@anchorageal(.gov> Subject: Re: GREEN FOREST BLK 2 LT 7 To clarify, HDPE tank without a MH can be installed per old code till 4/15/21? c 18 (,%/o Ygva t-3Ct-�( Thanks, Brent M. Western First Water Consulting 907-350-9566 1 OV—) Siv�eQ +� `Y\Al 1, 20 I C1.. SS SSSS SS S SS0° 10' 00"E 159.00'N0° 10' 00"W 159.00'24.242.311.0 14.9 32.128.3 40.150.2S89° 59' 00"W 96.36' GRAVEL DRIVEWAY PAVEDDRIVEWAYCONCRETE SIDEWALK 10' UTILITY EASEMENT100' WELL RADIUSW 25' R.O.W. ℄ HUFFMAN ROAD ℄ SILVER SPRUCE DRIVEWOOD DECK WOOD DECK 32.5 21.112.9LOT 6 DOT R.O.W. TAKE 2009-075866-0 10' TEL. EASEMENT Lot 7, Block 2 Green Forest Subdivision Unit No. 1 3,320 Sq. Ft. +/- 12401 Silver Spruce Drive 1 Story Wood Frame House With Attached Oversize 2 Car Garage N89° 59' 00"E 96.36' T12N R3W SEC 29 PARCEL 2 23.3 63.3DECOMMISSIONED WELL 8/25/21 PROPERTY IS NOW ON CITY WATER AS OF 8/24/21 39.6 34.3 47.0 PROFESSIONAL SEAL Date:Frontier Surveys, LLC Project No: 650 W. 58th Ave. Suite E Anchorage, Alaska 99518 As-Built Survey of: www.frontiersurveys.com Frontier Surveys, LLC I, Pierre Stragier, hereby certify that this Mortgage Inspection Survey was performed by me, or under my direct supervision on Plat:Grid:Ordered By: 907.460.1686 - info@frontiersurveys.com This survey complies with the ASPLS Mortgage Location Standards. The survey represents visible improvements and conditions at the time of the survey. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may reveal. It is the responsibility of the Owner to determine the existence of any easements, covenants, or restriction which do no appear on the record plat. Under no circumstances should this document be used for construction or for establishing a boundary or fence line. August 19th, 2021. Legend: Scale 1" = 25' Gas Meter Electric Meter/Outside Power Deck Septic Telephone Pole Fence S G E Lot 7, Block 2 Green Forest Subdivision Unit No. 1 General Notes: 1. This document is created for the purpose of a single property transaction and is subject to Federal Copyright Laws. 2. Excepting for gross negligence, the liability for this survey shall not exceed the cost of preparing this survey. 3. All measurements/setbacks are to the visual/apparent building footprint. 4. All dimensions to property lines are plus/minus 0.1ft. Hollie Kennedy 21-621 08/23/2021 66-134 2833 W Water Wellx STA T E O F ALA S K A49 TH ROYEVRUSDNALLANOISSEFORP DERE T S IGER Pierre M. Stragier NO. LS-9812 08/23/2021 Over Hanging Power E G EDGE OF PAVEMENT 50' R.O.W. 4/15/2020 Municipality of Anchorage P.O. Box 196650 a 4700 Elmore Road Anchorage, Alaska 99519-6650 ® (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.org/Onsite Development Services Department On -Site Water and Wastewater Section �ivci�t S, * * * * VARIANCE/WAIVER REVIEW * * * * Waiver#: OSV201016 COSA#: Permit#:OSP191138 PID#: 018-011-10 Legal Description: Green Forest Block 2 Lot 7 Engineer: First Water Consulting Applicant: Candie Caraway Your request for a waiver of the required 100 feet horizontal separation from the septic tank to the private well has been approved. The approved separation distance is 66.0 feet. In addition, the following reduced separation distances have been approved for the well and septic system on this lot. • Well to existing crib approved at 71 ft. • Well to existing absorption field approved at 93 ft. • Well to existing sewer main and manhole approved at 57 ft. • Existing absorption field to well on Green Forest Block 2 Lot 6 approved at 89 ft. See engineer's waiver request and recent well water sample results for justifications. This waiver approval applies to the proposed septic tank and the existing wells, crib, and absorption field only. Any fixture upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. .............................................................................. 1 Waiver is Granted: X Waiver is not Granted: Date: 5 2 0 Approved b • pp Y• Ls Name of Reviewer **** VARIAN C E/WAIVER REVIEW **** MUNICIPALITY OF Ame Development Services Department On -Site Water & Wastewater Section Parcel I.D. 018-011-10 ANCHORAGE ON-SITE SEPTIC/WELL PERMIT APPLICATION EP&+AIS Phone: 907-343-7904 Fax: 907-343-7997 Property owner(s) CANDIE CARAWAY Day phone 9073519451 Mailina address 1661 GEORGE BELL CIRCLE, ANCHORAGE, AK 99515 Site address 12401 SILVER SPRUCE DRIVE, ANCHORAGE, AK 99516 Legal description (Sub'd., Block & Lot) GREEN FOREST B2, L7 Legal description (Township, Range & Section) Lot Size 15321 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial El Single Family (SF) (w/wo AD U) Septic Tank ® Upgrade ® Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES WAIVER REQUEST FOR: I / C -'l i�'enc SP_WV_r (AO-k,y) It rn�h�kzle_ ` Distance: %(, 4L? LeU oni Loi- to + 6 I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. FWCS - Brent Western (Signature of property owner or authorized agent) Permit/Rush Fees: aa5T Date of Payment: q12( 1(9 Receipt Number: uY&M Permit No. 05pfq 113'8 Waiver Fees: 0 f 1 �D " 2 51 _ 13 5 Date of Payment: Receipt Number: 1(5 5 Waiver No. 0- 5'V � 0 j n I (a GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client FormsTermit Application.doc 13030 Sues Way, Anchorage, AK 99516 907-350 -9566 / firstwaterAK@gmail.com April 13 , 2020 Municipalities of Anchorage On-Site Water & Wastewater Program 4700 Elmore Road Anchorage, AK 99507 RE: GREEN FOREST BLOCK 2, LOT 7 - UPGRADE PERMIT WITH WAIVERS The monitoring tube of the existing trench was repaired and a favorable adequacy test performed on the crib and trench. We are therefore proceeding forward in obtaining a permit to upgrade the aged septic tank with waivers. We respectfully request separation waivers from the existing well to the proposed tank of approximately 66’, well to crib of 71’+/-, and well to trench of 93’+/-. Per MOA record documents, it appears the adjacent Lot 6 well is approximately 89’ to the trench on Lot 7 and therefore we request a waiver of 89’. Also, the referenced well existed prior to the existing public sewer main and manhole. We are therefore requesting waivers to the manhole and sewer main of 57’+. Granting of these waivers are justifiable based on area nitrate levels, the attached recent nitrate results, the elevation / location of the subject well to the proposed HDPE tank (improved tank material), existing field and sewer manhole would prevent any possible effluent flowing directly towards the well. The adjacent well on lot 6 is also up gradient from the septic system on Lot 7. The area soils consist of slow percolating silty material with low probability of effluent transference. AWWU record drawings state the sewer line was “heat shrink (seal all joints) with a similar waiver granted for Lot 1 to the west. These encroachments have existed since 1970 with with no known issues and the wells would almost sure to be free or no contamination possible from any form of household sewage contamination from the septic system or sewer line. Granting these waivers will not impact any of the neighboring properties and we respectfully request that these waivers be granted. If you have any questions or require additional information, please contact us at 907-350-9566. Sincerely, Curtis Huffman, P.E. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191138, Rebecca Carroll, 04/15/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191138, Rebecca Carroll, 04/15/20 � NeW) SGS Ref.# 1201293001 Client Name First Water Consulting Services (FWCS) Project Name/9 Green Forest B2, L7 Client Sample ID Spigot Matrix Drinking Water Sample Remarks: Parameter Results LOQ Metals by ICP/MS (<10) Arsenic 10.5 * 5.00 Waters Department C Total Nitrate/Nitrite-N ND 0.200 Microbiology Laboratory E. Coli Negative I Total Coliform Negative I r� Printed Date/Time 04/13/2020 13:03 Collected Date/Time 04/06/2020 14:10 Received Date/Time 04/06/2020 14:23 Technical Director Stephen C. Ede Allowable Prep Analysis Units Method Container ID Limits Date Date Init ug/L EP200.8 B (<10) 04/09/20 04/13/20 DMM mg/L SM214500NO3-F C (<10) 04/07/20 EWW IOOmL SM219223B A 100mL SM219223B A 04/06/20 VAB 04/06/20 VAB `a DRIVE WAY (~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME P~O-~-~'- LEGAL DESCRIPTION ~ O [I DISTANCE TO: [I Well Absorption area Dwelling PERMIT NO. ~ /Manufacture~ ~- ,~ Material Ne. of compartments ~Liq. capacity in gallons IF HOMEMADE: Inside length Width Liquid depth ~ ~ DISTANCE TO: Well Dwelling PERMIT NO. ~ ~ ¢ Manufacturer - Material Liquid capacity in gallons ¢ t Foundation Nearest Io2~e/ PERMIT NO~ ~ DISTANCE TO: = ~ eachT]i ~z~ No, of lines / Length of . ~eI Total length~of~lines~ Trench wi inches ~:~ Toper tileto fini~ 9rade~ I ~- Material beneath tile 3 I in~ Total effectiveabsopt~ Length Width Depth P~RMIT NO. ~ ~ Type of crib Crib diameter Crib depth Total effective absorption area ~ Well Building foundation Nearest lot line ~ DISTANCE TO: ~ Class Depth Driller Distance to lot Hne ~ERMIT NO. ~ Building foundation Sewer line Septic tank Absorption area(s) ~ DISTANCE TO: OTHER PIPE MATERIALS SOIL TEST RATING g ~,~ , APPROVED ~ , / DATE LEGAL '" ' '" L:-OIJFit;:E LC~T S(?[{ , -,/' ' ~;::[f'll.ll't HI_IHFEP OF BE[",F-i(-uTq'I:5 :: "~ /[! F:E~)IJIF:E[', '::[:.:7[:': OF THE Sl_q[l FtE:L:-.CIF'PI'[OI"I ::-.Y::-:T[~P1 [:5 , EFE F:" ' I t-I =;: ' ': L_ E:C I'--1 (Z;i -1' I -t .... ~ --' .., t-:. I- I .,- ::_ L. 'ltiE LErIGTft [:,IHENSION IS THE LENGTit (IN [rEEF;', OF FHE TPEtJI]FI f'HE E:,EF']H OF FI 'I-I~:ENCt4 CI[;: F'IT I¢ THE [',IN,.'Fti'.,hL"E E:Li"I'I,IEEt/ [FIE 15LII;.'FIqCE' [iFH]JI.If'I[:' RIq[:' THE DOTTOt'I OF ]'HE: E:":!]:R","RTION < IN FEET) THEF'E IS I',10 '_T,E{T HI[:,TH FOR T'E:Ei'iC:HES ]'tie GF:.'R'v'EL. DE?TH 15 ]'HE I,,IlHIH, UI"I [:,EF'TFI OF GF.:FtVEL E:E]'HEEN THE OLITFF. ILL PIPE I~tll-) THE E',OTTEIPi OF THE E'F::CR',,,'FtTIOtl ,::Il,.[ FEET) · F'~t,I I I F--.': [~E I;?' :5;E'] F'-F I f": T'F:tI"4 t'c; c..; 1E ;-.7; IZZ .... ' ~' '- (Y ~ ") C3iFIL. I_ ;F'PllT Fh°F'I_IC:Ftt'iT 1-41~i_'2-.; THE f;:E¢;F'OtL-;IE::,IL[T'F lcI II,.,IFf_-IE'P1 'FHi:~; [,EF'FiF'FI'IEI,Ef DIlPI'tlG f'itE- 4z. lf,LLftllr_-~ti I,~_.FLL. I iEII'.L::. OF I-:Ii'PC HEI._L:3 Fd",fF~EI,tT Ti.) Tt-[f? F'F:OF'E.'ITTY ,'nil'ti, rite lifE:ER: OF F'ESTE',ENC:ES 'THFtT TIlE HELL HILL _,~:._.,,_. ...... -T I.l('TI ,( ::Z_' ;:, .[ i'-I :~_'¢F' E:C C__7'l- I F_;~l"-.l':.'i; !:1 i';7 L-!:: I:;i:[Z_ (;:! I._.1 I t-::t-~_12 ........ c, ,c.-..-, '¥Hr_'H I r F' t f H':.: .r:'EC:T I -2H Ri'.i[, F!F'F'F:DVF:iL E:"¢ I H I :~: iC. PiF'ILL_ING OF Flhl'f' _.~_.lEtl H[ NRL . :!:'FIFTTf'l[':'.flT FIII I_ E',E '~I.I[~',..![:'I]:T1-1.] ':'F'Oi~'~E!]:IJTION. NI,r'IlJH l;,I'SlT:ttlE:E E:E'fHEEi'I R fi,ELL FCJ[', fql,'t"r' ON-SI1-E ~;EI,IFIFiF_' [.,ISF'EuZ-.;F~L. ?,r'~;;iEf'l ~O FEEl' F'r)F: F~ F'F.:I'v'FITE NELl_ GF' 1L-';O TO 2;OO F'E[{T ,~:F:Ot'i fl F'LIE:L[(:: NELL 'Otl TH[- l'r'F'[ OF F:'UE:LI( I.IL:! L. l,lIl,,lI_lH [,I'_~:TFfi,ICF~ FF:OPI FI ,n'F:I',,,'F~I'E NE!_L. TO t:1 F'F;TI'v'F~TL; '~:£::I,JE:F: L [tie I'q ?% FELl,' ~ !t COHI,11_II,III-'¢ qEI,IEI?. !._INE I'_-.-, ;;5 FEFT 'L[. [ FI,3'~ liP:El F:E,..!LIE:ED F'IN(':, f,lil'3T E:E t:'~-;TI..1F'I,,!IE[:, TO l~iE [,EF't~R:i'HENT H[ FHIH ]O 7liE:- l,i[-I L i_OHF'LIETIE~I,I. 14[F' FtI.:-OI.I[F'EHEt',FF5 F.IR'¢ RF'F'L'¢ '7.1:'EL':IFIIZi~T["]'ItP_'¢ i:li'd:, r]FJN%I,'[;:'I. ICTILqN (;:,If-!(];F;:Fil'I% HF'E · 'Fi I I_fl[!:LE TO I,;'i::_':LIF'E F'RF_iF'EF: ! i'l%iF~!_t_FIf' [ FFF'I I F"r' l~i,'1 F'Ht'I[LIF~: I,IiTlt '['FIE ftEg!LlIF.'L{r'l[.:ZhiTS f:'Cff;: C?,'-!_-;['I-E '5EHEF.?:5 ftHD HELLS ff:']H [.:','¢ Trl[? I'IIII,iIC'IF'FILII'¢ 17:F' HIt_L. [N;.~,'IHLL THE ?¢STE'hl Il'.! FtCC:OPE',F4NCE I,I~'I'H THE' LItlE,[-jF'S. TI~HE, 7~{Ftl THb F,N-SIIE F~EHff[;' ~;'¢S'FETf'1 P!FIY [:'~I.)LIIPFZ ENL_t~F:GEI'IEtlT IF THE [',FI-ICE [ S F'LPUL'IF:,EL. ED TO I NCt_LIf.,E hlOIq'E ri4Rfi ::: E'EDF'OOP1E; Fd-'F'L l' FI/l, / ~ PERr,.1.T'f' 1'40. ,:: 800548 ::, FIPPL I [::RNT L. IDCRT ]: O1.',1 I....E .r.~RL ¥: I}EPFIRTMENT (:,. HERLTH RND EN, :[.F.1.1flE1.~'THI.. F. JTECTION ':'-:'5 "' L "' .., [ F..EE I'., FINC:HOF.:RGE., FIK. r:'l"l ..... ~ .... ,? ~ ':'I' 4 ;;- 4.1;144. [:,. F'. KRUFMFIN SRR r.-.,_,.., ::, .[ L. El4. LOT 7' BLI< 2 GREEN FURE_,T =I_IB LOT SIZE :J ....... ._2. F.;L.]URRE FEET T'¢F'E OF SOIL RB$ORF'T .T ON SYSTEM IS: DRR.TNFIEL[:, MF:IXZMLIM NIJME~ER OF EEE. RUOrl .... :~;O[L RR'FZNG ,:::~;~;! [ r. [.,R.. .... ~ THE RE('::II..I.TRE[:, )]IZE OF THE SOIL RB90~EM IS: .D THE DEPTH OF R TRENCH OR PZT I5 THE E:,Z~TRNCE BETHEEN THE SURFRCE OF THE GROUND RND THE E~OTTOM OF THE E',,4CRVRTZON ,'.:~N FEET). THE GRRVEL DEPTH IS THE MINIMUM DEPTft OF GRR',,,'EL BETWEEN THE OUTFI=ILL. F'IPE FIN[:, THE BOTTOM OF THE EXC:RVRTION (IN FEET::,. F'ERMI'f' FIPPLICRNT FIFIS THE RE:BPON'SIBILIT"r' TO INFORM THIL=; [:,EF'RRTMENT DURING THE .TNSTRLLRTIOI'4 INSPECTIONS OF RN'¢ 14ELL:5 RDJRCENT TO 'rHZ2: PROPEF.:T'.r' laND :'HE NUI"IE:EF:: OF" RE~I[:,E1.',ICE:~; THFIT THE HELL HILL ~ER',/E. E=FICKF'.TLLING OF FIN'¢ S'T'$TEP'I 1.4ITHOUT F'ZNRL .TNE;I::'ECT.TON F'IN[:, RPPROVRL B"r' THZ5 E:'EF'RR]"MENT 1.4.TLL BE SUE',JEC'i" 'T'O F'ROSECUTION. M]:N.TMLIM DI2;TIaNCE BETHEEN I::1 1.4ELL FIN[:' FIN"/ ON-:.:".]ITE :~E!-,.IRGE DI':;POSFIL 'Z~;'¢STEM I:5 :'L00 FEET FOR R F'RI',,,'Ia'rE HEI...L OR :1.50 TO ;F'(~E~ FEET FROM R PUBLIC HELL DEPEN[:,I1..,IG UPO1..,I THE T'.r'PE OF PUBL.TC HELL I',I~.NIMUM DTS'rRNCE FROM FI PRI',,,'I=ITE HELl_ TO FI F'RI',/'RTE: L:;EI. qER LINE .TS 25 FEET Ft1..,tD "FO R COMHIJNIT'-r' SEWER LINE .TS 75 FEET. OTHER RE6!UIREMENT'_E; MFfT' RPF'L*r'. 2;F'EE:.TFICRTION:5 FIN[:'., C:ON'.-];]"F.:IJCTIOI'.,I E:,IFIGRFIMS FIRE: I:::I',/RILRBLE TO INSURE PROPER I1..,ISTFILLFIT.TON. I E:ERTIF'T' THFIT :.1..: I lam FFtMIL. II=IR HITH THE REQUIREMENTS FOR ON-SITE SEI.,.IER. S R1..,I[:, I,.IELI_'.5 RS '.SET FORTH B'¢ THE MUNIC IPRL I T'T' OF FINCHOF.:RGE. ;:2': I HILL INSTlaLL 'THE S'¢:E;TEM II",I*~BCCORDRNCE [4ITFI THE CODE)--',. ]:: I U1.',IDEf;.'.STRND THRT THE ON-"2ITE', SEHER S"r'STEM 1'4R"r' REL.]UIRE ENLFIF.".GEMENT IF THE RE~5.T[:'ENCE I2:;., REMO"'" E[:' '.] IIqC:L. I I.[ ~ C~R THFII".! 3: BE:E:'F.~OOMS. -, · -% .... " · '%-' 9 <-/ /.2/.,-.Z¢,~','- ¢' RF'PL I CE)NT [:,. P. KF. Ir.!F~f,IFIN '~ , -- SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6,660, Anchorage, Alaska 99602 276-2221 SOILS LOG - PERCOLATION TEST PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1 2 3 4 5 6 7 8 9 lO 11 12 13 14 15 16 17 18 19 20 LOPE // DATE PERFORMED: WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? SITE PLAN L L _L ~ L~ L. E ! J Gross Net Depth to Net Reading Date Time Time Water ,d~/~,*¢ Drop ~ / 7.'- -z: /J" /7, J- o 1 7.' gY /:'- i~', .??.r' o, ~ z/' '~ PERCOLATION RATE TEST RUN BETWEEN (minutes/inch) 'II!F; I.l::.l",lljilli I;,i.j'Jhili:::,i(li',l I!~:, ilJJ J J,l!:iilJ ' Ji',J JZi ! ' 1'4 iJil}i i1,.I i,u i !fl;; j,, iHE:[:~:}::: ] '_{; {'.~f) ii:J] I ld i:lJ:,l Jl i ~_ii,-' j l,:'i-i,h :{ il :::, 'i!11::: I:ii,l:ll',,,'t::l ii:,l::l':'iil :[:; 'iiih: HIl'.,iiiiiii'i i,,:i:']li ~.lp (d, i::l',,,'i :i !:;i~ihit:i i'~ ii[l' FI!'-,ID i t'li:i i:',[) i 'i I ii,i, I.q:: i i ii. : ,.,, I v'" ' ' i i I Ii',I , Ii'.i' ' i i , ~ ,,~ I:::l(~:l':::J:: ] I..J ]i t'.,i iJi Ell: Iii?,' ::::,"l":, l li't i,J I. I i ii ]1..I i I: i Ni !I i i,!':;iz'J:.I i I_!l',J I If,ii :' Ill i ii i,,:l ii ]: ~ i ~ I q ':, t!:1::"1:11'? t Hli:N I t,.i:i:[i, h:i': :.,I. II..:, ]l::'i:. i 'i (! l:'l,:i.F:,il Ii I ~ I [l'i ]:l',tJil"ll.li"l I]:i]ri:J;'l'l:::tl"~l]:!:: l:3t{!i'-ii:ii:::i''i Il Ni.~i. L. Iti''i!' ::!Irih' ()i''!''i]: il:: :i;l: J'l":il]ii' I']r::'J':J)i;?:Ii ',:~',ii j'[ i ' Ii!:.11:;'1 I::'l}!ii~ii i:E[I;: I::1 I'fl;:i]","l;lli.] i'!l;{I i I)i'i' ::'I::U:I iii ' i *d':' l~ F:'lli:"l Iii: I'lih i 'l I I1: l:;:i t:;.'.l~i]l:;;!l..I]:t;::lJ:Hl!l'4 i:::' HF:I? I: :I F:' I :' [ "i". ::;:,r'~:]l : I j' !!.;I ii il!Nj::, ! It''fl) I :l II',i'r; i i''i ii i I li''i i) i iu i'' i I~ri' I [ ~ ~ L ~ ~',"1:1.i] L.l:li;:::i.. ht I (] t l''i:i'i ii;:;L{ F'I':U li:'i:: I':: I i''?:i:' ! I! I I:! i ! I ii4 GR~6.TER ANCHORAGE AREA BORO[RqH HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 279-2511 NAME LOCATION . IN~SPECTION ...~; ~h'(~:~(~.~-t?.~,: / REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LEGAL DESCRIPTION SEPTIC TANK: COMPARTMENTS GALLONS. INSIDE LENGTH \ INSIDE WIDTH - DISTANCE FROM WELl. LIQUID CAPACITY PHONE__ / LIQUID DEPTH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS LINING MATERIAl ~ NEAREST LOT LINE / OUTSIDE DIAMETER ~ OR WIDTH Z '7 ~:~.,~t ~J- TOTAL EFFECTIVE ABSORPTION AREA (WALL ARE,A) ! / LENGTH_ / '7 . DEPTH BUILDING FOUNDAflON "~¢J ~ i ;~ so. ET. TILE DRAIN FIELD: D ISTA N C/.ErqOM WELL NUMBE~' OF ABSORPTION AREA TOTAL LENGTH · FOUND~ NEAREST LOT LINE ~ OF LINES D s~.c~'''~ ~' "~ ~' ' SQ. FT. LENGTH OF EACH LINE DEPTH: fOP OF TILE TO FINISH GRADE _DEPTH OF FILTER MATERIAL BENEATH TILE IN. ABOVE TILE WELL: TYPE ..~/~/ Z ~ , DEPTH /¢') ~r LOT LINE ~'~_~ ! NEAREST SEPTIC , SEWER LINE ~J'~/- _,TANK DISTANCE FROM , BUILDING FOUNDATION. /~.~ ,j- 7>~// SEEPAGE ~':-?-, / SYSTEM WAFER ' SAMPLE /~'~ . NEAREST OTHER , CESSPOOl "~ , SOURCES DIAGRAM OF SYSTEM DISTANCES: DATE GAAB-I-I D-2 GREATEI 327 Eagle St. ANCHORAGE AREA HEALTtl DEPARTMENT Anchorage, Alaska 99501 DROUGH 279-2511 SEWAGE DISPOSAL SYSTE/'~ - APPLICATION & PERMIT , / ILING:- ADDRESS.].`]`- ? / 9; c,, ~ ,:'! PHONE NO._ t - , SEEPAGE PIT / , DRAIN FIELD TO SE INSTALLED BY ~]< ( J [ [ 52~//~}~NTICIPATED DATE OF COMPLETION BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT ~' ' (~,( , PERMIT TO INSTALL A .)c'~.~.,dq j NAME OF APPLICANT~i( / RESIDENCE ADDRESS APPLICATION TO INSTALL: SEPTIC TANK TO SERVE THE FOLLOWING FACILITY FINANCED THROUGH <-'~" PERCOLATION TEST RESULTS ' ') ~ THIS IS TO SERVE AS , OTHER AS GESC,.~ED ~ELOW. S,ZE OE UN,~ZO ,~ SERVED . ~;:~ . , .SEPTICTANKSIZE~/?('~ TYPE , 2'(/d'~_SEEPA~EAREA 9~ /~TYPE DISTANCES: ) (J~ '//I x' X.: / I certify that I am familiar ~vith the requfl'ements of Greater Anchorage Area Borough Ordfllance No. 28-68 and that the above described system is in accordance with said code. DATE ) x APPLICANTS SIGNATURE ~ ~; ' - .z " / /'/ ? GAAB-HD-2 GREATEI. ANCHORAGE AREA . {)ROUGH HEALTH DEPARTMENT 327 Eagle St. Anchorage, Alaska 99501 279-2511 SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT Case No._ NAME OF APPLICANT RESIDENCE ADDRESS LEGAL DESCRIPTION APPLICATION TO INSTALL: SEPTIC TANK TO SERVE THE FOLLOWING FACILITY F~NANCEO THROUGH ,,~/-/,~ 'PE'~ TEST RESULTS ~ , SEEPAGE PIT v'/ , DRAIN FIELD , OTHER. TO BE INSTALLED BY ~.)-; L/~-,,"~Z)'~ ANTICIPATED DATE OF COMPLETION ;'~ q'4-/'S~[LOW TO BE FILLED OUT BY HEALTH DEPARTMENT THIS IS TO SERVE AS /I'"/~//~ ,)r/~/////&:~ , PERMIT TO INSTALL A AS DESCRIBED BELOW. SIZE OF UNIT TO BE SERVED , SEPTIC TANK SIZE _,/~.5~ TYPE ~"~'~/~'/~:~/?/'?""~EEPAGE AREA DISTANCES: /:,1/ ¢- ( / ~ Hea~th Authority TYPE DIAGRAM OF SYSTEM I certify that I ain familiar with the requkements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above described system is in accordance with said code. DATE ~/' ~'///~ APPLI CANTS StG NATU R E- ,f('?)'Tq 4 1o iREATER ~NCHOR^GE ~REA BOROUGH HEALTH DEPAJ;:THENT CASE 327 EAGLE S, TREET ANCHORAGE, ALASKA' 99501' Legal Descz'zptzon= ~ot ~X. OCK ~ b~xvxszon (-,~eo~ ~,, ~ ', ~ c- · ln.~s rcmm KepOP~S a, ~ol~s ~og__~ 'remco~at~on Test Depth Feet Soil ChaPact e~'istics Location Was Oround Water Encounte~ed?=,~_.'.~.___Q~ If Yes, At What Depth Read Date Gz~oss Time Net 'rime Proposed Instal~tionl---~eepage Pit ~ D~ain Field Deo~h Of Inlet ~nu~.m~w~, ~/ , . , ,)eptn fo Bottom Of P~t Date~._. ,. · .a ~,~'- /C ALASKA GEOLOGICAL CONSULTANTS ENGINEERING GEOLOGY ~' MINING ~' GEOPHYetlCB '~'GROUND~YATEH ~' PETROLEUM 2227 SPENARD ROAD ANCHORAGE, ALASKA 9g~03 April 28, 1970 Mr. Charles Hight 1503 A, Star Route A Anchorage, Alaska Re: Percolation characteristics of soils, Lot 7, Block 2, Green Forest Subdivision Dear Mr. Hight: The attached report presents the results of an investigation of the percolation characteristics of soils on your building site. On the basis of this investigation we conclude that 275 square feet of seepage area per bedroom will be required. Very truly yours, Hj M: js cc: GAAB Health Department ,// ALASKA GEOLOGICAL CONSULTANTS H. j. Moenmg ~ Attach. "'- ·'~ DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME ~ME ~ -/ ~ATE DATE DATE INSPECTOR INSPECTOR I NSP ECTO¢~ . MUNICIPALITY OF ANCHORAGb MUNICIPALITY OF ANCHORAGE DEP'I. OF HEAVrH &  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEd~N~ENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTION~: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing, ~ PHONE MAILING~ESS PROPERTY RESIDENT (If different from above) PHONE 2. BUYER PHONE MAILING ADDRESS 3, LENDING INSTITUTION I PHONE MAILING ADDRESS 4. REALTOR/AGENT ~~ J PHONE ~A~MNG ADOR6~ 5. LEGAL DESCRIPTION Zo.,,- 7. STREET LOCATION 6. TYPE OF RESIDENCE NUMBER OF~BEDROOMS [] One [] Four [] 1~ SINGLE FAMILY [] Two 71 Five E] MULTIPLE FAMILY ~ Three --] Six Other 7. WATER SUPPLY INDIVIDUAL* [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG, A well Icg is re~ uired for all wells drilled since June 1975, For wells drilled prior to that date, give well depth (attach Icg if available.) 8. SEWAGE DISPOSAL SYSTEM ~ iNDiViDUAL/ON.SiTE~ [] PUBLIC UTILITY YEAR ON-SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. 72-010 (Rev. 6/79) i_l,~_~ THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE [~] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX 2. WATER SUPPLY PERMIT NUMBER [] INDIVIDUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified. LOG RECEIVED 3. SEWAGE DISPOSAL SYSTEM PERMIT NUMBER []INDIVIDUAL/ON -SITE DATE INSTALLED E~PUBLIC UTILITY / 0 -- ~ _, Connection Verified INSTALLER []Septic Tank or []Holdin9 Tank Size: ]OO0 If Tank is homemade SOILS RATING §ire dimensions: "~YPE OF TANK MANUFACTURER ~'~OTAL ABSORPTION AREA MATERIAL ~', DISTANCESwELL TO: Septic/Holding Tank Absorption Area Sewer Line Nearest Lot Line '~bsorption Area to nearest Lot Line 5, COMMENTS PROVED FOR _~- BEDROOMS [] CONDITIONAL APPROVAL (letter must acco/ml:r~ry, xcertificate) [] DISAPPROVED 72-010 (Rev. 6/79) ~ D/~E RECEIVED INSPECTION APPOINTMENTS TIME _ TIME TIME -~ATE ~.~ _~ DATE DATE MUNICIPALITY OF ANCHORAGE MUNiCiPALITY OF ANCHORAGQ  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DEPT. OF 14EALTH & 825 L Street - Anchorage, Alaska 99501 ENVIRONMENTAL PROTECTION ENVIRONMENTAL SANITATION DIVISION SEPt 9 1980 Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER ..... DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed, Please allow ten (10) days for processing. 1. PROPERTY OWNER /~' PHONE ~AILING ADDRESS ' PROPERTY RESIDENT (If different from above) PHONE 2. BUYER PHONE MAILING ADDRESS ~ LENDING INSTITUTION ~ I PHONE MAILING ADDRESS 4. REALTOR/AGENT I PHONE MAILING ADDRE88 5. LEGAL DESCRIPTION STREET LOCATION 6. TYPE OF RESIDENCE SINGLE FAMILY [] MULTIPLE FAMILY 7. WATER. ~UPPLY INDIVIDUAL* COMMUNITY PUBLIC UTILITY N~UMBER OF,BEDROOMS One [] Four E~-.,.Tw o F~ Five [~"~-.-~hree [] Six [] Other * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior t0tha[ date, give well depth (attach Icg if available.) //~:/¢-.~ ,~ 8. SEWAGE DISPOSAL SYSTEM ~ iNDiVi DUAL/ON.SiTE.~ [] PUBLIC UTILITY YEAR ON:SITE SYSTEM WAS INSTALLED. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCEssING CAN RE INITIATED, THISSIDEFOROFFICIALUSEONLY · . 1. TYPE OF RESIDENCE NUMBER OF BEDROOMS [] SINGLE FAMILY [] ONE [] THREE E~] FIVE [] OTHER [] MULTIPLE FAMILY [] TWO [] FOUR [] SIX PERMIT NUMBER 2. WATER SUPPLY [] INDIVI DUAL DEPTH OF WELL [] COMMUNITY DATE DRILLED [] PUBLIC UTILITY Connection Verified LOG RECEIVED 3, SEWAGE DISPOSAL SYSTEM PERMIT NUMBER [] INDIVIDUAL/ON -SITE DATE INSTALLED []PUBLIC UTILITY Connection Verified INSTALLER - []Septic Ta~nk or []Holding Tank Size: [000 If Tank is homemade SOILS RATING give dimensions: TYPE OF TANK MANUFACTURER Septic/Holding Tank Absorptio,~rea ~ewer Line I Nearest Lot Line 4, DISTANCES Absorption Area to nearest Lot Line 5, COMMENTS ~ CONDITIONAL APPROVAL (letter must accom~ertificate} August 28~ 1980 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & FNVIRONMENTAL PROTECTION SEE: 2 6 1980 RECEIVED ASI NO 01680 Mr. David P KauFman Star Route A Box 1512B A'nchorage, AK Re: Adequacy Tesk Fcc Existing Septic System on 'Lot 7, Block 2, Green ForesL Subdivision Dear Hr. KauFman: Ab your request ou~ office conducbed a percolation adequ'acy' test on your existing septic syste~ at the above-referenced location during the period August 26 and 27, 1980. You reported that your septic system consists of 1000 Gallon SLeel septic tank with a 17 ft. X 17 Ft. X 9 FL. seepage pie with 3 concrete rings installed in 1970. The septic ~ank had not been pumped prior to the percolation kesk. Since the ~-bedroom house had been occupied up to the time of the test, a normal degree of saturation ~i~hin the leach Field i~ assumed. [n accordance w~th ~he Anchorage Municipal ~de~ Chapter ~aste'~ater Disposal Regulations, any on-si~'e sewage disposal system "shall have adequate capacity to prop~r~y dispose of the maximum daily sewage Flow.." The maximum dai~.y Flow is computed at 75 gallons per capita-day (gepd). Since 'A~he population of dwellings shall be estimated at two persons per sleeping room~" the maximum daily"sewage Flow For your ~-bedroom h~u~e is 450 gallons per day (gpd) To test 'the soils absorption capaciky of your system an attempt was made ED add 110 percent of the maximum daily Flow or 500 gallons of clear ~ater in 50 gallon increments to the seepage pit. The water was obtained From your on-site private well. '/he liquid levels were monitored closely'to detect any backup in the septic system. The attached Table of Test Data repcesenEs the depEhs of the liquid in the septic tank and seepage pit and Ehe quantities of Mr. David P. Kaufman August 28, 1980 Page -2- On Day 1 an attempt was made to add 500 gallons of water to the seepage ~. The seepage pit was filled to the top three times in two hours wi~h~72 gallons of water. On Day 2_.~n attempt was made to add 500 gall6n~ ~-~ater fo [~e--see~age pit~t a reduced flow rate of approximately 1 gpm. The seepage pi~ ~as filled to the top with 1~5 gallons in two hours. Two hours later the seepage pit was filled to'the top again with 50 gallons, ~ total of 185 gallons for Da~ 2. After diseussing the results with you, the test was stopped at the end of Day 2 w~th no indication of positive results. We appreciate the opportunity given to perform this adequacy test. If you have any questions regarding these test results, please contact this office. Very truly yours, ALASKA SOILS ~NVESTIGATIONS Project Manager SDS/MK/mf Owner: Address: Adequacy Test for Existing Septic System David P Kaufman Star Route A Box 1512 B Project. No. ASI 01 680 Legal Description: LoL 7, Block 2, Green Forest Subd. Components of Septic System: 1000 Gal. Steel Septic Tank/9' X 7' Seepage Pit(1971 Number of Bedrooms: 3 Occupied prior to test: Yes X No How long vacant: Test performed by: M. KjelsLad Initial Static Levels: Septic Tank 7.0~ Last pumped: July 1979 (?) Water meter/S.N. 2281 2186 ; Seepage Pit 9.2 ' T MST DATA :rime Septic 'rank Seepage Pit Added~ gal Reading, gal Remarks 11:46 4.5 2.5 -0- 23,367 ~ev~sIn 11:59 4.5 1.4 50 23,417 12:12 3.5 .6 48 23,465 Stopped 12:41 4.1' 1.0 -0-- 23,465 Resume 12:51 3.3 .2 25 23,490 Stop 1:05 3.85 .75 -0- 1:11 3.95 .85 -0- 23,490 Resume 1:15 3.3 .2 27 ?~ ..... 27~517 SLop 1:39 4.0 .9 -0- 2~\~517 Resume l/Z Gal 1:44 3.3 .2 22 23,539 Stop 1:58 5:03 4.5 2.0 -0-L Check level 10:47 2.2 12 24,268 10:57 2.0 13 24,281 11:07 1.8 8 24,289 David P. Kaufman Project No. 01680 ~egal Description: Lot 7, Block 2, Green Forest Subd. TEST DATA (Cont'd) Liquid Depth, ft * Water Meter Time Septic Tank Seepage Pit A~ded, gal Reading, gal Remarks 11:17 1.45 14 24,293 11:27 4.5 1 .37 7 24,310 1 .2 9 24,319 11:47 4.2 1.15 10 24,329 11 .57 4.05 .85 12 24,341 12:17 3.75 .6 23 24,364 12:27 3.6 .45 11 24,375 2 hr. 12:29 3.25 .1 7 24,382 135 Gal 2:43 4.5 1.75 -0- Check 2: 46 4.5 I . 75 -0- 24,384 S~ar~ 6: 30pr 2.0 -0- TerminaLe T-est ANCHORAGE CESSPOOl.. PUMPING Star Route A, Box 144 ANCHORAGE, ALASKA 99502 Phone 344-2632 or 344-2453 All claims and returned floods MUST be 4 35 SERIES 609 Gk~.,FER ANCHORAGE AREA BOROUGh DEPARTMENT OF ENVIRONMENTAL QUALITY 3500 TUDOR ROAD ANCHORAGE, ALASKA 99507 279-8686 DATE RECEIVED:. I NS PECT: TIME: REQUEST FOR APPROVAL OF INDIVIDUAL SEWER AND WATER FACILITIES FOR 1. APPROVAL REQUESTED BY: ///_~?~)/~,~?' ADDRESS: ~:C,~'/ ~'~, 3, LEGAL DESCRiPTiOn: ,?~)/'~ , /~5)T~ / 4. TYPE FACILITY TO BE INSPECTED: NUMBER OFl BEDROOMS: ,~ WELL DATA: A. TYPE B. DEPTH D. CONSTRUCTION ~'~] E. BACTERIAL ANALYSIS SEWAGE DISPOSAL SYSTEM: A. SEPTIC TANK (IF HOMEMADE, SHOW DIAGRAM ON BACK) 4. INSTALLER APPROVAL REQUEST fOR SEWER & WATER FACILITIk~ PAGE TWO B, SEEPAGE PIT 1. SIZE ,"'7' X 17' 2 LINING ..) ~z~/~ C. DISPOSAL FIELD ~/.~ 1. NUMBER OF LINES Z. TOTAL LENGTH REQUIRED MEASUREMENTS A NELL TO SEPTIC TANK B ~ELL TO SEEPAGE PIT C NELL TO SEWER LINE D NELL TO PROPERTY LINE /(X" E WELL TO OTHER POSSIBLE CONTAMINATION F FOUNDATION TO SEPTIC TANK G FOUNDATION TO SEEPAGE PIT H SEEPAGE PIT TO PROPERTY LINE COMMENTS: APPROVAL VALID'FOR ONE YEAR FRO~ DATE ~]~NED. GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY KASSLER/WEST MORTGAGE CORPORATION 604 EAST SIXTH AVENUE .ANCHOI~AGE, ALASKA 99§01. 212-9!B01 DATE: FEBRUARY 7,_J_972 GI~IiATIiR ANCIIOI),A(;li AI),I~A BOI~OI. IGI4 ])cpl. of linvironnlental Ilealth Pouch 6-.630 Anchorage, Alaska 99502 P, li: JOHNSON, Jim l,egal: Lot 7, Block 2 Green Forest Subd.~/ (;ent lomen: Per the attached form, we hereby request ~nspectJ. on For Ilealth Authority hpprova]. Please send your findings to e:ither the FIIA offices or the VA Office as noted above for the "Case Number'.' Also, pJease send an exact copy of the report to otiF office. Your swiftness in expediting this request would be most appreciated. Sincerely, ]<ASSI,ER /WES'I MORT(]AGI} CORP. P.S. ]f you wish to make an appointnlent before inspect]on, please call ~ i m or MFs.