Municipality of Anchorage
Community Development Department Pagel of 3
On -Site Water & Wastewater Program
4700 Elmore St. • P.O.
Box 196650 Anchorage, AK 99519-6650 • http:llwww.muni.org/onsite • (907)343-7904
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP121005
PID Number: 050-521-35 ❑ New N Upgrade
Name:
TONY GONGLIEWSKI
ABSORPTION FIELD
® Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address;
25427 BLACK PINE CIR.
*EAGLE RIVER, AK
❑ Other
Soil Rating:
Total Depth from original geode:
Phone:
No. of Bedrooms:
907-694-8669
4
0.6 GPD/Sq. Ft.
11 MAX Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade:
Grovel depth beneath pipe:
SEE DWG. Fl.
5.03 & 5.02 Ft.
Subdivision:
Block: Lot:
Fill added above origiml geode:
Gravel length:
GROLL S/D
2 6
SEE DWG. Ft.
50 + 50 = 100
township: anger
ec ion:
-
Gravel width:
Beds Number of lines:
Distance between linew
- -
2.5 FL
N/A
N/A Ft.
SEPARATION DISTANCES
Total absorption area:Number
1000+ Ft.
of trenches:
2
Dist. between trenches:
10+
To
Septic
Absorption
Lift
Holding
Public/Private
From
Tank
Field
Station
Tank
Sewer Lines
So.
Ft.
Well
too'+
100'+
-
-
25'+
TANK ®Septic ❑S.T.E.P. 01-lolding ❑Other
Manufacturer.
Capocity:
Surface water
100'+
100'+
-
-
ANCHORAGE TANK
1250 G.J.
Lot Line
5'+
10'+
-
-
NA
Material:
Number of comportments:
STEEL
2
Foundation
5'+
10'+
—
—
LIFT STATION
Curtain Drain
NONE KNOWN
Manufacturer: Capocity:
-
Got.
'Pump or, level at:
lump off Isvel o(:
Ni or alarm at:
Remarks: OLD SEPTIC TANK WAS DECOMMISSIONED PER UPC.
Pump Make & Moder
teicol Inspections performed by:
PIPE MATERIAL
House to tank D-3034 Tank to D-3034
drainfield
Installer WHITTERS
EXCAVATION
Drainfield D-3034 CO/MT D-3034
Inspector GEG, Ltd.
BE MARK (Assumed elevation)
100.00 FI.
Inspection
Dates: 1st 5/14/12
2nd 5/14/12
I.ocobon and Dascriplion:
3rd -
4th -
TOP OF CONCRETE SLAB Q GARAGE
ENGINEER'S SlA
Community Development Department Approval00
o p
poi
F
�F
Conditional approval:
Date:
:9 v0
.............. ..........
p. .... ........ p
QO P Gar ess•-
E vp
Q�4pPPa••b.�d�la�';�000
iill�l�,,�
Date:�f�7"
4QQ Profession
Approve
o
Inspection Rep&r�1-1-12.doc
PERMIT NUMBER: AS BUILT DRAWING PARCEL ID NUMBER: I
OSP121005 050-521-35
TESTHOLE LOCATIONS WERE
APPROXIMATE ON THE DESIGN.
LOCATIONS SHOWN ON AS -BUILT
DRAWING ARE CORRECT.
/ OLD DRAINFIELD CONNECTED
AS A RESERVE SITE--(
TH#i
1&2
— NEW 1250
GALLON DEEP
BURIAL SEPTIC
TANK
i
/
/ y Fki f
yOG� �b c
SF.
4
HNSULATED SEWER LINE v EXISTING
UNDER DRIVEWAY WELL
, Y
( THICK, 4 WIDE)
PER CONTRACTOR
100' WELL RADIUS --
NEW DRAINFIELDS I
1
1
1
OF SLOPE (APPROX.)
OF SLOPE (APPROX.)
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
3701 E. N1 FMO. Wn 101 • aucxOwGE. M N W] • FNONE (9071337-61N • 9M (907)336-3346 • MM": �w.9ommengina•ring.cam
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
TONY GONGLIEWSKI 907-694-8669 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
GROLL SUBDIVISION; BLOCK 2, LOT 6 1 PNB/JLM
TYPE OF WORK:
AS -BUILT DRAWING
(Rev.01105)
6/6/2012
PERMIT NUMBER: AS—BUILT DRAWING PARCEL ID NUMBER:
OSP 121005 050-521-35
/rr FINAL GRADE = 99.63-100.47
ST1 / ST2
TOP OF TANK j TOP OF TANK
AT INLET= 92.16 AT OUTLET = 92.15
NEW 1250 GALLON
INVERT OF BUNG SEPTIC TANK INVERT OF BUNG
AT INLET = 91.54 AT OUTLET = 91.42
FINAL GRADE jft
rORIGINAL GRADE = 93'17-93'34 ORIGINAL GRADE = 93.45
FINAL GRADE MT I = 90.65 ® HIGHEST POINT
= 9n 77-99.84_ B ® HIGHEST POINT
FABRIC
FABRIC
INVERT OF PIPE
= 87.47
:RT OF PIPE
= 84.68
0+
BOTTOM OF TRENCH = 82.45
BOTTOM OF TRENCH = 79.65
RELATIVE ELEVATION OF BOTTOM OF TESTHOLE = 73.45 (GW ® 75.45)-sILL
RELATIVE ELEVATION OF BOTTOM OF TESTHOLE 7386 (DRY)
00600 ��
GARNESS ENGINEERING GROUP, Ltd. p * 4 `•
CONSULTANTS& GENERAL CONTRACTORS """ "' • •••"• "" ..
37D1 E. 79C9R RM. SURE IDI • ANlW C. M 996D7 • MW (907)337-6179 • FM (9D7)336 M" • wE9a a —9.m range imq .m
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: •• •. ...•••• ......••
TONY GONGLIEWSKI 907-694-8669 3 OF 3 O e f ey Go ess;
LEGAL DESCRIPTION: DRAWN BY: Oo9 CE 79 3O
GROLL SUBDIVISION; BLOCK 2, LOT 6 PNB JL QQ'e ''•(R4F c°d
TYPE OF WORK: DATE: 4�OPloOOOofess!0
PROFILE AS—BUILT DRAWING 6/6/2012
(Rev. 01/05)
On -Site Wastewater Disposal System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP121005
Tax Code Number: 05052135000
Work Type: Septic Upgrade
Permit Effective Dates: January 19, 2012 to January 18, 2013
Design Engineer: GARNESS
Subdivision: GROLL
GROUP. LTD.
Site Legal Address: GROLL BLK 2 LT 6 G:0262
,tr-1`/-t2
57-14-12
Owner/Address: GARNESS ENGINEERING GROUP, LTD.
3701 EAST TUDOR ROAD, STE#101 JENS JENSEN ANCHORAGE AK
Site Mailing Address: 25427 BLACK PINE CIR, Eagle River Lot Size in Sq Ft: 126168
Total Bedrooms: 4
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
C 4)_ * 3 0
r 3;0
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: PRIOR TO CONSTRUCTION: Verify the trench design with another
percolation test at the location, 'Proposed Confirmation Test Hole", as shown on page 2/3 of the
design.
Special Provisions: The permit includes waiver OSP121008, allowing the drainfield to be 35 feet
minimum from a slope that is 25% or greater.
C 01 ►^e U seS �I�e arra `� �''�! d �.(�
Received By:
Issued By: �!—hC kllyw X __k� Dater
Municipality of Anchorage
P.O. Box 196650 9 4700 Elmore Road
Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997
http://Www.muni.orn/Onsite
Development Services Division
On -Site Water and Wastewater Proaram
n.ent
SPS
S L
n
v.
Department
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSP121008 COSA#: Permit#:OSP121005
PID#: 050-521-35
Legal Description: Grolt, Block 2. Lot 6
Engineer: Garness Engineering Group
Applicant: Tony Gonaliewski
Your request for a waiver of the required 50 feet horizontal separation from the absorption field
to the 25% or greater slope has been approved. The approved separation distance is 35 feet.
This waiver approval applies to the proposed absorption field only. Any future upgrade to the
on-site wastewater disposal system will require all separation distances be met or another
approval from this department.
❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
® Adjacent properties are not affected by this waiver.
...............................................................................
Waiver is Granted: x Waiver is not Granted:
Date: Approved by 1,
Name of Reviewer
..............................................................................
Rec#: 0179OG Amount: $200.00 Date Paid: 1/19/12
**** VARIANCEIWAIVER REVIEW ****
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
Development Services Fax: 907- 343-7997
On -Site Water & Wastewater Program
Mayor Dan Sullivan
On -Site Sewer/Well Permit Application
For A Single Family Dwelling
Parcel I. D.
Property owner(s) TONY GONGLIEWSKI Day phone 907-229-5314
Mailing address 25427 BLACK PINE CIRCLE * EAGLE RIVER AK * 99577
Site address 25427 BLACK PINE CIRCLE * EAGLE RIVER, AK * 99577
Legal description (Sub'd, Block & Lot) GROLL S/D; BLOCK 2, LOT 6
Legal description (Township, Section & Range)
Lot Size
Sq. Ft. Number of Bedrooms 4
THIS APPLICATION IS FOR:
THIS APPLICATION IS AN:
(E all that apply)
Initial ❑
Absorption Field
®
Upgrade
Septic Tank
❑
Renewal ❑
Holding Tank
Privy
❑
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE/ WAIVER REQUEST FOR:
I certify that the above information is correct. I further certify that this application is being made
for a Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING GROUP, Ltd.
(Signature of property owner or authorized agent)
Permit/Rush Fees: s3 L 00 Waiver Fees: '�y0 `:-o
Date of Payment: l Ila 11), Date of Payment: 1 1 q /1 a
Receipt Number: (12qG7 Receipt Number: O )''�01)0 C�j
Permit No. OSQ1,21005 Waiver No. 02 Q/,) 1 a69
(Rev. 01/11)
a i i. GROUP,,
i `.
! CONTRACTORS
January 2012
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Rd.
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907)343-7904
Ref: Proposed Septic System Upgrade for Groll S/D; Block 2, Lot 6
To whom it may concern:
The existing 4 bedroom house is served by a private well and septic system. The septic
system is in a state of failure and needs to be upgraded. We are proposing to install the
alternate site identified on the original 1995 design an
Sol I wmummzzffip� or the original 1995 Robert C. Cowan, P. E. design, two
test holes were excavated on the property. The alternate drainfield will be designed
around the 30 foot radius of the test hole #1. A confirmation testhole was excavated by
Whitters Construction on December 29, 2011, and logged by GEG, Ltd. to confirm
groundwater separation. This test hole was excavated directly next to the original test
hole #1. We are proposing that a confirmation test hole be excavated as shown on the
design drawing to confirm soil condition are the same on the east of the proposed
drainfields. Comments regarding the design are summarized as follows:
1. SOILS: Since the 1995 test holes were dug, approximately 5 feet of fill has been
added in the area. We are basing our design therefore on the original test hole depth,
adjusting 5 feet to remain true to the original soil elevations. See the attached log which
shows the soil classifications and groundwater monitoring.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATER: There is no surface water within 100 feet of the proposed
upgrade.
4. TOPOGRAPHY AND SLOPE WAIVER REQUEST: As can be seen on the attached
design, the slopes below the drainfield are approximately 10-15% running northeast to
southwest. Approximately 35 feet downhill from the lowest trench, there is a slope that
ranges from 35 to 50 percent slope. Attached is a profile drawing showing the worst
case scenario in regards to the slope. As you can see, the 25 percent slope 2 feet
above the top of the drainrock (2.5' above the invert of the pipe) daylights approximately
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.gamessenginecring.com
44.5 feet downhill from the lowest trench. The steep slope is heavily vegetated and is
believed to consist of fill that was created at the time of the construction of the house.
We request that a 35 foot waiver be granted to a slope greater than 25 percent slope. It
is our opinion that there is minimal concern with the granting of this waiver.
We are unaware of any adverse impacts this installation would have on adjacent wells
or septic systems. If you have any questions, please contact us at 337-6179. Thank
you for your assistance.
, P. E., M. S.
NO TE.- Attached is a site plan drawing, a design drawing, one soil log, which are all part
of the design package for this septic system. (Contact G. E. G. Ltd. for 7 page
construction specification letter)
3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507-1259
Ph: (907) 337-6179 * Fax: (907) 338-3246 * website: www.gamessengincering.com
\
GROLL S/D;
\
BLOCK 2, LOT 4
\ HIDEAWAY S/D; LOT 5B,, \ \
DAMMAN CIRCLE
N
E:
1 • = 100'
1
LOYE S/D; BLOCK 3B, LOT 2
\ c�F
.9�
:XISTING SEPTIC SYSTEM \,
EXISTING \
4 BEDROOM
HOUSE \
a �
EXISTING
WELL
100' WELL RADIUS I
1 1
\
SEPTIC UPGRADE _ _ i
T74N, R1W, SEC 23; NE4 NE4 NE4 SW4
C2
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS • • •
3701 E. NOOK ROM. 5U 101 • Il1CXORAOE. M 98507 • PHO 90))337-6179 • FM (OrAM-3 S ieEEbRE:.e�.99rnannginashp.c O
PREPARED FOR: PHONE NUMBER: PAGENUMBER: •• •••• •••••• ••••••••
TONY GONGLIEWSKI 907-694-8669 1 OF 3y f y GOrn sS:'
LEGAL DESCRIPTION: DRAWN BY: oOO 9� GE— ct'G
GROLL S/D; BLOCK 2, LOT 6 J.L.M.
TYPE OF WORK: DATE: �QOO4 fe slo �o
CITE PI AN rnP SEPTIC SYSTFM I IPr PAT)F 1 2012
1nev. uvw)
Lot
/ NOTE: THE CONTRACTOR SHALL HAVE THE SOUTH
LOT UNE FLAGGED BY A REGISTERED LAND
SURVEYOR PRIOR TO ANY CONSTRUCTION.
EXISTING DRAINFlELD TO BE
CONNECTED AS RESERVE SITE
':9..
m
m
OF BEDROOMS: 4
PER DAY (GPD): 600
PION RATE/S: 32 k 8.5 MIN/IN (20.25 AVG)
D APPLICATION RATE: 0.6 GPD/FT'
DRAINFlELD SO.FT.: 1000
MAXIMUM DEPTH: 11 FEET
WIDTH: 2.5FEET
LENGTH: 100 FEET (2 O 50 FEET LONG EA.)
EFFECTIVE: 5 FEET
ACTUAL SO.FT.: 1000
PROPOSED ZABEL FLOW DNERTER
INSTALL DOUBLE CLEANOUTS
—EXISTING SEPTIC TANK TO BE REMOVED
AND REPLACED WITH A NEW 1250
GALLON DEEP BURIAL SEPTIC TANK
—PROPOSED DRAINFlELDS.
ALTERNATE SITE FROM 1995
ROBERT C. COWAN DESIGN
-TOP OF SLOPE (APPROX.)
OF SLOPE (APPROX.)
i
IN
/ �--INSULATE SEWER UNE
UNDER DRIVEWAY
(4" THICK, 4' WIDE)
PROPOSED ZABEL FLOW SPUTTER
TO OBTAIN A COPY OF THE LETTER
CONTACT GEG. BY PROCEEDING FORWARD
WITH THIS INSTALLATION, THE ENGINEER,
WELL DRILLER, CONTRACTOR AND
PROPERTY OWNER AGREE THAT THEY
HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND
OF
GARNESS ENGINEERING GROUP, :Ltd. * 4T �*
CONSUILTANTS & GENERAL CONTRACTORS .......... . ....... ........
3]01 E TUWR M . SME 101 w MlCHUR C M 9950] r p E (907]33]-61]9 • W (907)336-3246 • WE M- www.gormaa,n9>n"0n9 �n
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: .•. . . ... ••••••••
TONY GONGLIEWSKI 907-694-8669 2 of 3B
G ess•-
LEGAL DESCRIPTION: DRAWN BY: Q4 9, CE-79��
GROLL S/D; BLOCK 2, LOT 6 A.J.G. O�Q @ e '�!`I Fe2'' FpAd�
TYPE OF WORK: DATE: 40Qapro f sslona\
DESIGN OF PROPOSED SEPTIC UPGRADE REV. 5/14/12
(Rw. U1N5)
GARNESS ENGINEERING GROUP, Ltd.
�rr�r CONSULTANTS & GENERAL CONTRACTORS
E. R610R FOU). SUITE 101 • MCXOPME. m 99507 • R E (90)73])-6119 • FM (9(Y1)336-3246 • MEBS rrrAa^6999M�^6ef^9.9�
EPAREDFOR:. PHONE NUMBER: PAGE NUMBER:
TONY GONGLIEWSKI 907-694-8669 3 OF 3
;AL DESCRIPTION: DRAWN BY:
GROLL S/D; BLOCK 2, LOT 6 J.L.M.
1E OF WORK: DATE:
DETAIL OF PROPOSED DRAINFIELD 1/6/2012
I`
A. Ga*r essi
Coi
GARNESS ENGINEERING GROUP,
CONSULTANTS & GENERAL CONTRACTOR$
101 E NOOK ROAD, 81ME 101 • ANq RkM W. 99307 • PHONE (907)337 -GIM • PAX: (90)3W-320 WEBBOE: W..91, mq.
SOIL LOG — PERCOLATION TEST
... ... .. ............. .
LEGAL DESCRIPTION: GROLL S D; BLOCK 2, LOT 6 '.J r A. Garn ss.:
�r
PERFORMED FOR: TONY GONGUEWSKI DATE: 5/10/2012'Os ^P ••/I1t 17,•.DEH��Avv4
(f e Q �oO41Ofesskoo0
TEST HOLE #2 (CONFIRMATION TH)
1
2
5
6
7
8
9
10
11
12
13
14
15
16
17
18
SOIL CLASSIFICATIONS
"i
DATE
DRY
5/10/2012
DRY
5/11/2012
ILI
shtt I 1?.
6"
-
2
GP
30
ML
3.5"
3
3:44
-
6"
-
4
4:14
30
2.5"
3.5"
GM
4:14
CL
6"
-
6
4:34
30
2.5"
3.5"
GC
OL
9°9 o
SW
MH
•' '
•••.•
t
SP
CH
SM
OH
SC
DEPTH TO
GROUNDWATER
DATE
DRY
5/10/2012
DRY
5/11/2012
ILI
shtt I 1?.
6"
-
OSP
O
r = loo,
DATE READING
CLOCK
TIME
NET TIME
(MINUTES)
WATER LEVEL
READING
NET DROP
(INCHES)
5/11/2012 1
3:14
-
6"
-
2
3:44
30
2.5"
3.5"
3
3:44
-
6"
-
4
4:14
30
2.5"
3.5"
5
4:14
-
6"
-
6
4:34
30
2.5"
3.5"
19� PERCOLATION RATE 8.5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 7.5 FT. AND 8.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: E YES ❑ NO
SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY: ROB CAMPBELL
COMMENTS: -m -(-Ur= CLoSsj I%/L
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PFtRFQRMFD IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
GARNESS ENGINEERING GROUP, Ltd
CONSULTANTS & GENERAL CONTRACTORS -
101 E. NDOR ROAD, SORE 101 • ANCHORAGE, M. 8950 • NONE. (907)337-61]9 • FM: (907)336-3246 • WOSRE: g9meeeengineaNnq.con
SOIL LOG
— PERCOLATION TEST
LEGAL DESCRIPTION: GROLL S/D;
BLOCK 2, LOT 6
PERFORMED FOR: TONY GONGLIEWSKI DATE: 12/29/2011
DEPTH
(feet)
TEST HOLE #1
1
SOIL CLASSIFICATIONS
2
3
—
ORGANICS/FILL
x�°'
GP
11111111
ML
=
GM
CL
4
GC
OL
°° 0 0 o
SW
MH
5
'��.::
.
SP
CH
J rA. G rness;'
C — 3
Qs
W\1?r°fasslDn°\ o
SM off SEE ATTACHED
6 SC SITE PLAN
7
8
9
10
11
12---]1I"II'^:''I GW TO GM
13
14
15
16
17
18
DEPTH TO
GROUNDWATER
DATE
DRY
1?/2/11
I I�
19� PERCOLATION RATE _ (MIN./INCH) PERC. HOLE DIA. _
TEST RUN BETWEEN FT. AND FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES ❑ NO
SOILS LOGGED BY: ROB CAMPBELL PERCOLATION TEST PERFORMED BY: —
COMMENTS
— (INCHES)
PERFORMED e5T ttU, LLa. I, JtrrrctT A. UAKNt55, GLKIIhY IHAI THIS WAS PjERF/ORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: I /Q /1 2,
a Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: 7;��.J 1.�1u AG1.. f G kl S1L (
LEGAL DESCRIPTION:1/o
DgPTY
nET) C>R--
1
2 S
3-
0/1 0/ r
4 /
5 /
7 n
8 / .
9 r�i
10
,• r
11
12 - 0.
13-
14-
15-
16-
17
314151617
18
19
20
COMMENTS
5
5wrt
WAS GROUND WATER
ENCOUNTER ED?
S
IF YES, AT WHAT t L
0
DEPTH? 117
P
E
Depth to Water Atter
Monitoring? np�aale: °0�1�'�S
DATE PERFOR
Section:
ROBERT C. COWAN
SITE PLAN
Reading
Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
S -1 `•1.95
' cs "
—
'L
Mli.l
�gL
t N
PERCOLATION RATE 3Z' tminuteslinch) PERC HOLE DIAMETER G
TEST RUN BETWEEN FT AND FT
PERFORMED BY: a R C r: CINEERING I LA'L1 D CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ,�`t I RIYBLI�'I.WS*G dNo.2Q�F g,Zt _q5-
��gle ��Ver, as a 9//GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
s
C
PE
LE
TEST RUN BETWEEN . I FT AND 's FT
PERFORMED BY: S $ S ENGINEERING1 Andyh.u.� D _
17334 Eagle R ver Loop OO e. 2 TEST WA5 RMED IN
ACCORDANCE WITH *.Wo %$NRIW0)VfXr.UIDELINES IN EFFECT ON THIS DATE. DATE: g'� z')' `r
72-M (Rev. 4/85)
Municipality of Anchorage Page 1 of 2
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 a Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: PID Number: _05(3'-.5zi -" 35
Name:
Wastewater System: 1 New 11 Upgrade
%1r�swtd
.�� Ga��
Address:
1•/106 GcS,v1o5 nu_ r1cN• I K `i`r61
ABSORPTION FIELD
Phone:
� ..Z � � �,i r
No. of Bedrooms:
_
0 Deep Trench fiS.Shallow Trench O Bed O Mound ❑Other
LEGAL DESCRIPTION
Soil Rating:
Total Depth fro�o�iginal grade:
GPD/Sq. FL
{c
Lot: e Block: 7 Subdivision:
pj
Depth to pipe bottom frpm original grade:
Gravel depth beneath 1 pipe
Vs G�(Geal L
Ft.
Ft.
Township:
Range: �d
Section: ,..
Fill added aboIe original grade:
Gravel length: 1
�' � + FL
Ft.
WELL: New ❑ Upgrade
Gravel width: 1
2 ,�5
Number of lines:
t
Distance between lines:
_ Ft.
Ft.
Classification (Private, A,B,C):
Total Depth:
Cased To1i
Total absorption area:
Pipe material: AS;T1rN n 303
i1e1 ATE
1 Ft.
1%p+ Ft.
`l SQ. Ft.
/ Flat D
Driller: a ^ p
JhtV / (4,L&
Date Drilled:
9 — li' "qG
Static Water Level:
71f Ft.
Installer:
WEf-0 G-x�kvvtTla�
Date installed: ,
-•
Yield:
Pump Set at:
Casing Height Above Ground:
"��
TANK
a GPM
li• FL
Ft.
SEPARATION DISTANCES
_
%Septic ❑ Holding ❑ S.T.E.P.
To
Septic
Absorption
Litt
Holding
Public/Private
Manufacturer:
Capacity in gallons:
From
Tank
Field
Station
Tank
Sewer Lines
polel.RoOrAGE TAtAr-
110
Well-
F
l�df f
--
� ,1
Material: Tf-EL
Number of C apartments:
IwI
Surface
Water
Papt#
Icet-F
""
w
—
LIFT STATION
Lot
1
t
_
Size in gallons:
Manufacturer: s
Line
�1$ ;
6c)
Foundation
1
g„
,s,
"Pump on" level at: "Pump o at:
High water alarm at:
�F.
Curtain_
1 a�
Jay
Veldt
Pump Make
Electrical Inspections performed by:
Drain
14
Remarks: �PTtc, "TAf-1k
BENCH MARK
Location and Description:
J CAC. _1600. V'urL Oa6p=/L
T m =- aar ov 000f,
Vurc, L
JnA Cbo P0, VAT 1119,1
Assumed Elevation:
IG
—S & S ENGINEERING
Inspections performed by:D4'Tt�QS4•
I"I
17034 Eagle—R—wer LOOP ROM,
Eagle River, Alaska 99577 2nd
R�O7 ERT C. COWAN C-
CE -8801
Z 1%
Department of Heal and Human Services approva
Reviewed and approved by: Date: -2/ -9
72-013 (Rev. 9/91) MOA 25
SW950268 2 2
Permit No. Page — of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 ® Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Legal Description:
LOT 6, BLOCK 2, GROLL SUBDIVISION PID No.: 050-521-35
IA zmll
PCS '
1
_!!!-
3
2
19.Q'
39,0'
DBL1
19
.0'
DBL2
19.5'
42.0'
CO
22.5'
65.5'
CO2_
74.0'
02.0'
MT1
73.5'
02.5'
SEPTIC YANK
DRQ
i
ALT. SITE
°r1
/� 99.4''ST2
—FINAL GRADE
TH{/1 /-4
/ NEW —
/ 91.5 1250 GALr,
002
MT,�
An
ST
FINAL GRADE MT1„CO1CO2 CO? _ — 9 .0'
85.
J Z4 B NO WATER FOUND
77.8' B.O.H.
e
SCALE 1" — .w 4Q9 �� P.,".� CE • 8801
o
1�
72-013 A (Rev. 0/91) MOA 25
Tprtlffirb Brining llxg
bN
DOC Co. tlba
SULLIVAN WATER WELLS
P.O. BOX 670272, CHUGIAK, ALASKA 99567 • TELEPHONE 688.2759
OWNER OF LAND
ADDRESSST,\TIC
LEGAL DESCRIPTION
DATE - Started
PERMIT NUMBER
__
Ended
DEI'"iH OF WELL
LEVEL OF WATER FI -
DRAM' DOWN FT. m
GALS. PER HR
KIND OF CASING _
KIND OF FORMATION:
From --Ft. to
Ft.
From.
Ft. to---- Ft.
From Ft. to .-
Ft.
From
Ft. to__Ft. _
From— Ft. to
Ft.
From
Ft. to_ Ft.
From Ft. to
Ft.;'_________
From
Ft. to--F(--
oFt.
From—Ft.
From Ft. to
—Ft.
__ - - From
Ft. to—Ft—
o FtFrom
FromFt. to
Ft.___
- - From
Ft. to Ft.
From Ft. to i
Ft.
_ From
Ft. to_ Ft.
From + "> Ft. to
Ft.
____ From
Ft. to _Ft.
From Ft. to
Ft.
—. __ From
Ft. to--F(.—
oFt.FromFt.
From—Ft.to—Ft,----.-
From
Ft. to Ft.
From Ft. to
Ft.
From
_ Ft. to Ft. �—
From Ft. to
Ft.
From
___._ Ft. to__ Ft. —
From Ft. to
Ft.
From
Ft. to –Ft.
From Ft. to
Ft.
From
Ft. t t
From Ft. to
Ft.
From
Ft. to_ _Ft._
From Ft. to
Ft.
From
Ft. to i Ft.
From Ft. to
Ft.
Frmn
FiP f Ey%� Ghc aqB
MISCL. INFORMATION
DRILLER'S NAME .__
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
DISPOSALSYSTEM
DESIGN
S&S
nc,
Date:
ROBERT C. COWAN, P.E.
ROBERTA. SHAFER, P.E.
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
RECEIVED
JUN "191996
Municipality of Anchorage Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES Npt. Health & Human Services
825 L Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
REFERENCE: Z_ o. (!I/000
The septic inspections for the referenced property were
performed onG/� '& and _ 6_113,1eila. Prior to submitting
the On --site Wastewater Disposal and/or Well Inspection
Report we are waiting for the u a�� to be
completed.
If we may be of further service please contact us.
Sincerely,
Robert C. Cowan, P.E.
17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE k
DEPARTMENT OF HEALTH AND HUMAN SERVICES n
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650--�`)L'
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
LD
PERMIT NUMBER:SW950268 DATE ISSUED: 9/08/95
DESIGN ENGINEER:S & S ENGINEERING EXPIRATION DATE: 9/08/96
OWNER NAME:GONGLIEWSKI ANTHONY & TAMMY
OWNER ADDRESS:4106 COSMOS DR.
ANCHORAGE, ALASKA 99517
PARCEL ID:05052135
LEGAL DESCRIPTION:
GROLL BLK 2 LT 6
LOT SIZE: 132727 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
RECEIVED BY:
ISSUED BY:
DATE:
DATE: /" `�2
S&S1
din epunG
August 24, 1995
ROBERT C. COWAN, P.E.
ROBERTA. SHAFER, P.E.
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
HEALTH AUTHORITY
APPROVALS
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK. 99519
SEWER & WATER
MAIN EXTENSIONS
REFERENCE: Lot 6, Block 2, Groll S/D
Request you issue a permit to drill a well and install a
SEWER&WATER
septic system to serve the proposed four bedroom house on
INSPECTION
the referenced property.
Test holes were excavated and percolation tests performed.
The approximate locations of: the test holes are located on
ENGINEERING STUDIES
the attached site plan.
AND REPORTS
At the time of excavation water was encountered at 10 feet
in test hole #1 and no water was encountered in test hole
#2 and after seven day ground water monitoring, the
WELL INSPECTION
&FLOWTEST
monitoring tubes were found to be dry.
This property has enough area for a future septic upgrade
which can be seen on the attached site plan.
SITE PLANS
We do not anticipate any adverse effects on neighboring
wells, septic systems or drainage patterns by the
installation of the proposed septic system.
ROAD DESIGN
There are no points of contamination within the proposed
well radius which can be seen on the attached site plan.
SOIL TEST
The proposed 1250 gallon septic tank is to be placed
outside the protective well radius. Attached is a site
plan which depicts the location of the proposed tank.
PERCOLATION
If you require additional information, please contact us.
TEST
Sincerely,
STRUCTURAL&
MECHANICAL
Robert C. Cowan, P.E.
INSPECTIONS
RCC/gk
Enclosure
ON SITE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577
1 ' = 60' SITE PLAN DESIGN
SCALE
ro
myz --1 A 0,c zo W
Zt
o r
NWN�3OO P > D
7• cn "� 0 — co Z r
@
M 0 t�tj F
® F- ''I fl >i i0 b 0
\, wzmnv�N II _
m cn
trJCD o�o
o
C)
�pN-
00
Ln
F-
m e
7j N P O
G ps m
➢N vn
ONO ZSA C7
�m �m�,W 050
�� rq;U�CZri
Z 7n (Ah -1 =m
z - 0 m (n D
.Zl .TJ rR� N of M (n 1-- <
m
m O
mQ �, � ")�a ?9 0 .P Ohm m-f� y
Z --p on�G��� CCiP "�m�� -0nA mZ, m
m
Nm V�� �J� Ci�� j0O�ZO� I
U zvn rC-,� 7zyA N
-'l m vM?Ly9WmM I
o z U y i, -i • • CAO CD
o� mm \ 70v0�l �0 W
O _
°� \ O oDZ _C) :n
o= 2
n0 IIS,-� >n �m -
O00 zz
'0� / zA 0� O
s
°' 2s
r
[i PU A D 71
z 1
m C) r/ a zea fl
nzp-1 z
onzm J f
on Ion /
SNF; �• // DOS
< D
,yF�n
V11
71n
LEGAL DESCRIPTION: L/DT L�, 1,J 'OLtr`SLTownship, Range, Section:
SLOPE 7— SITE PLAN
VC)(L.-- F I ( ,
1 /
2 s
3
4 v
5 /
6
7 n
;
8 /
9 r�1 ,
10 °
11
12 Rj 0.
13
14
15
16
17
18
19
WAS GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT I L
O
DEPTH? �t7
P
E
Depth to Water After
Monitoring? V V Date:
Reading Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
Municipality of Anchorage
t DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
- "; 4. x
SOILS LOG —PERCOLATION TEST
a
r•51. :1?^!�?",x...�:,��
Ir ;� ROBERT C. COWAN
PERFORMED FOR: p ��. �u 1 L.l.r I %w� SIL 1
DATE PERFORM1x:)':. „9"5 w
LEGAL DESCRIPTION: L/DT L�, 1,J 'OLtr`SLTownship, Range, Section:
SLOPE 7— SITE PLAN
VC)(L.-- F I ( ,
1 /
2 s
3
4 v
5 /
6
7 n
;
8 /
9 r�1 ,
10 °
11
12 Rj 0.
13
14
15
16
17
18
19
WAS GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT I L
O
DEPTH? �t7
P
E
Depth to Water After
Monitoring? V V Date:
Reading Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
2
MI.�
VI
N
20I PERCOLATION RATE �� (minutes/inch) FERC HOLE DIAMETER
II � TEST RUN BETWEEN FT AND .5 ---FT
COMMENTS ��
PERFORMED BY: 5 & G y: GINEERING I .n� D CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH )yZ k le River Loop ad No. 204 21
Atgle EA. MSN GUIDELINES IN EFFECT ON THIS DATE. DATE:
Eagle IErver, as a
72-008 (Rev. 4/85)
or
� 01.(�.........ON
s " Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG —PERCOLATION TEST
C. COWANr
CE -8801 u�
PERFORMED FOR: +�P`� �(6p)L1E StL( DATE PERFORM�Ip
t 5-7p.
a.
LEGAL. DESCRIPTION: VO't"Io �J�h-��Z- 61PiO"Township, Range, Section:
FDEPTH7 SLOPE SITE PLAN
C]
2 �
3 /
G j
4 f!
5
6
7
B P
9 G�
10
11
12
13 /.
` i
14 '/ 16.-D,A
15
16
17
18
19
20
COMMENTS ry Z
WAS GROUND WATER O
ENCOUNTERED? T _
S
NIF YES, AT WHAT L O
DEPTH? p
E
Depth to Waterer
Monitoring.
Monitoring? 1- Date: _
Reading Date Gross Net Depth to
Time Time Water
Net
Drop
V-- P k -a -I o 0
Ali
'A3
t til / l 5 -
PERCOLATION
PERCOLATION RATE 3i (minules/inch) PERC HOLE DIAMETER ZO
TEST RUN BETWEEN FT AND ` -- FT
PERFORMED BY: S & S ENGINISERING I F4,-, VN uv� D _ CERTIFY THAT THIS TEST WAS PERFORMED IN
17034 Eagle River Loop Roado. 204 9 - 21 -
q. -ACCORDANCE WITH F ,T/Yj,N�IA,I} (;�Y957r-UIDELINES IN EFFECT ON THIS DATE. DATE: _
72-008 (Rev. 4/85)
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROADDESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ONSITE
WASTEWATER
DISPOSALSYSTEM
DESIGN
s&S�
�tne punq
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Lot 6, Block 2, Groll S/D
August 24, 1995
GENERAL:
ROBERT C. COWAN, P.E.
ROBERTA. SHAFER, P.E.
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
1. The scope of this project includes the installation of
a 1250 gallon septic tank and leachfield trench to
serve the proposed four bedroom residence located on
the referenced property.
2. Construction shall be in accordance with the approved
site plan and design drawings, Municipal permit with
any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal
Regulations.
3. The contractor shall be responsible for obtaining any
necessary underground utility locates.
4. Unless specifically agreed otherwise, the property
owner shall be responsible for final grading areas
subsequently depressed from soil settling.
5. Contractors installing wastewater disposal systems
must be certified by the Municipal Health Department
for system installations. Owners installing their own
systems must also receive prior approval from the
Municipal Health Department.
SEPTIC TANK INSTALLATION:
1. A septic tank is to be constructed by a certified
septic tank manufacturer. Construction shall include:
two 4" cleanouts for pumping access.
2. The septic tank shall be sufficiently bedded to
prevent settling or shifting of the tank.
3. All standpipes on -the septic tank shall extend a
minimum of 12 inches above final grade.
17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577
Page Two
Lot 6, Block 2, Groll SID
August 24, 1995
4. Septic tanks installed with less than 4 ft. of cover shall
be insulated.
5. A foundation cleanout shall be installed one to four feet
from the building foundation. In the line between the tank
and the leachfield there shall be two adjacent cleanouts
(unless an effluent pumping system exists within the septic
tank). These cleanouts shall be located on undisturbed
soil not more than 10 ft. from the tank. The first
cleanout, in line, shall be to clean toward the leachfield.
The second cleanout shall be to clean toward the septic
tank.
6. Final grading over the septic tank shall be such that a
positive slope exists away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
1. Excavate the proposed trench to the dimensions shown on the
design. The bottom of the excavation shall be within 2
inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (ruff -ed -up) before
gravel (sewer rock) placement.
2. Once the gravel is installed, the distribution pipe is to
be installed level with the perforations faced downward.
Gravel. is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
3. A silt barrier must be installed between the final gravel
layer and the native soil backfill. Ensure the silt
barrier covers the entire gravel surface before placing
backfill.
4. Monitor tubes shall be of four (4) inch diameter,
installed approximately in the locations shown on the
design, and extend a minimum of 12 inches above final
grade. The portion of the monitoring tube extending
through the gravel shall be perforated from -the bottom of
the trench to the invert of the distribution pipe. This is
equivalent to the effective depth of the gravel as noted on
the design.
Page Three
Lot 6, Block 2, Groll S/D
August 24, 1995
5. Backfill over the final gravel layer must not be less than
twenty-four (24) inches. Insulation must be installed when
the backfill depth is less than thirty-six (36) inches.
The finish grade over the trench must be mounded to prevent
the formation of a depression after settling.
MINIMUM MATERIAL SPECIFICATIONS:
1. Any septic tank proposed for installation must be
constructed by a Municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic
system installations in the Municipality of Anchorage:
Type of Pipe Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be
approved by the inspecting engineer..
3. Insulation shall be at least 2" thick extruded direct
burial. polystyrene (Dow Chemical Company Styrofoam HI or
equal).
4. Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N,
or equal) must be installed between the final leachfield
gravel layer and the native soil backfill.
6. All leachfield gravel (sewer rock) shall be 0.5"-2.5"
screened gravel with less than 3% passing the #7.00 sieve.
7. When sand is being used as a filter material, its gradation
specifications must conform to current M.O.A. or D.E.C.
requirements.
Page Four
Lot 6, Block 2, Groll S/D
August 24, 1995
INSPECTIONS:
Typically there will be a minimum of three (3) inspections
required during the installation of the wastewater disposal
system. These inspections will occur as follows:
1. The first inspection must be conducted after the
excavation of ditches, pits, trenches, or beds and
before the installation of any gravel. A septic tank
may be set in place, but may not be backfilled before
this inspection.
2. The second inspection must be conducted after the
placement of the silt barrier, gravel, distribution
lines, standpipes, cleanouts, and insulation, but
before the placement of any other backfill.
3. The final inspection is to occur upon final grading of
the property.
Often there will be more than these 3 inspections required.
Especially with the installation of multiple trenches, sand
filters, pressurized distribution systems, etc. Thus, the
inspecting engineer is to be contacted at :Least 24 hours prior
to the start of construction. If necessary, a pre -construction
meeting will take place on-site. The inspecting engineer will
not coordinate, direct or control in any way the contractors
activities.
The owner shall contract with the contractor to perform the work
outlined in these specifications and plans and in accordance
with the attached M.O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S
Engineering. S & S Engineering shall be the owner's
representative and will inspect the work as stated above to
document: the contractors activities. Final acceptance of the
contractors work rests with the owner and the M.O.A.
Page Five
Lot 6, Block 2, Groll S/D
August 24, 1995
S & S Engineering shall have no liability to the owner or to
others for acts or omissions of the contractor or any other_
persons performing work on this project or the failure of the
contractor to carry out the work in accordance with these
construction documents. S & S Engineering's inspecting engineer
will not be responsible for the construction means, methods,
techniques, sequence, procedures or the safety precautions
incident to this project.
CONTRACTOR/INSTALLER
MUNICIPALITY OF ANCHORAGE
• DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # 0 So - Sa, I - 3 s" HAA# 92,4e1DCOO
1. GENERAL INFORMATION
Complete legal description Lot 6; Block 2; Groll Subdivision
Location (site address or directions)
NHN Damman Circle
Eagle River, AK
Property owner Tony Gongliewski Day phone 242-5815
Mailing address 4106 Cosmos Drive Anchorage, AK 99517
Lending agency Day phone
Mailing address
Agent Day phone
Address
Unless otherwise requested, HAA will be held for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual,well XXX
Community well _
Public water
NOTE: if community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
4. TYPE OF WASTEWATER DISPOSAL:
Individual on-site XXX
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025 (Rev. 1/01) Front MOA #21
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm S & S ENGINEERING Phone '� _ a °► 7
17034 Eagle River Loop Road No. 204
Address Eaale River. Alaeka 998=7
Engineer's signature ; Wz 4�-A _ Date ) / a % R 7
6. DHHS SIGNATURE
Approved for bedrooms.
Disapproved.
Conditional approval for
bedrooms, with the following stipulations:
Additional Comments
By: Date
The Municipality of. Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates: based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the Stateof Alaska. The DHHS does this as acourtesyto purchasers of homes
and their lending institutions in orderto satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-M (Rev. 1/91) Back MOA N21
*eMunicipality of Anchorage /,
DEPARTMENT OF HEALTH & HUMAN SERVICES
Environmental Services Division
825 L Street, Room 502 • Anchorage, Alaska 99501 • (907) 343-4744
Health Authority Approval Checklist
Legal Description: Lar iv% , 6LUCK Z 1 6f-ol.i. //0 Parcel I.D.:_ oa v SZI -35
A. WELL DATA
Well type 67%0Pl-fes If A, B, or C, attach ADEC letter. ADEC water system number N +
Log present (ON)
Date completed q -1 `i 17.5
Total depth 11f Cased to 10 -f Casing height (above ground) 2 f
Sanitary seal ((VN) YFIs Wires properly protected PN) Y&s
FROM WELL LOG AT INSPECTION y
Date of test _ " 19 " `1l + ji
—�- ; r• 2
Static water level ?'f
Well production iia g.p.m.m.
WATER SAMPLE RESULTS:
Coliform V Nitrate O. f®o E' Other bacteria
Date of sample: 12 ! I 1°Ib 1�I��y Collected by: S & S ENGINEERING
1/034 Eagle pop Road, ft B. SEPTIC]HOLDING TANK DATA Eagla River, Alaska 99$77
Date installed 4am-13•-44 Tank size I Z50 Number of Compartments Z_ Cleanouts0/N) Yc.S _
Foundation cleanout (VN) `(E -z Depression Q0 Iv U High water alarm (Y/M tJv
Date of Pumping
Rao
C. ABSORPTION FIELD DATA
Pumper
Date installed (c> I:3j`I6 _ Soil ratingp,d./ orftz/bclrm) I > System type r(ZaA�+F
Length e Width Z •Si' Gravel thickness below pipe H. t _ Total depth
Effective absorption area _�° Monitoring Tube present (q�1V) '>Es Depression over field (Y(j %I o _
Date of adequacy test _ R X05 Results (Pass/Fail)
For _ l bedrooms
Fluid depth in absorption field before test (in.); Immediately after� gal. water added (in.):
Fluid depth (ins) Minutes later: Absorption rate =—g.p.d.
Peroxide treatment (past 12 months) (Y/N) _ If yes, give date
72-026 (Rev. 3/96)'
D. LIFT STATION
Date installed Size in gallons
Manhole/Access (Y/N) "Pump on" level at* "Pump off' level at*
High water al evel at* *Datum
Cy6les tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
ptic holding tank on lot 1001 + On adjacent lots too t
Absorption field on lot 100 ` ' E On adjacent lots ( 00
Public sewer main /� Public sewer manhole/cleanout p IV
t/ t$
Sewer /septic service line + Lift station rl
SEPARATION DISTANCES FROM SC HOLDING TANK ON LOTTO:
Foundation 0 t Property line 1 i6I t Absorption field Z8 ,
Water main/service line loft Surface water/drainage I net fi Wells on adjacent lots )no
0
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO:
Property line
Surface water
6p` +
Building foundation
Water main/service line
Driveway, parking/vehicle storage area
Curtain drain p�f4 Wells on adjacent lots foo If
* /V- 5 P e, &70 A( Li k r, IJ S LSI ,� v vN A- �,3 A
F. ENGINEER'S CERTIFICATION trtr� S <-�` n T•c ( w �s ��r 1-0 t; FL -ow, c)
�
1 certify that f have determined thru field inspections and review of Municipal records that the,' 46 ky�rem`s are � vo pf
in conformance with OA A guieynes in effect on this date. r w e
Signature
14 irk
Engineer's Name
1 �z� yih,!
Date h ROBERT C. COWAN w
V"-%, CE -8801
HAA Fee $DC7
Date of Payment — " / 7
Receipt Number 5/
72-026 (Rev. 3/96)* `�3g
Waiver Fee $
Date of Payment
Receipt Number
12/21/96 13:24 CT&E ESI ANCHORAGE � 9076941211 NO. 796 D02
CT&E Environmental Services Inc.
Laboratory Division rer�.rairaiviirs�.oirwia-�+r��.r�".r�rrrrrrrrrer.►sos
Dunking Water r'�nalySls Rnport for Total Coliform Bacteria 200 VV. 9e, AK 99516-1605
READ lr\'STRUMONSONREfIERSESIDE BE,ti'ORECOLLECTLYGSAYPLE Tel: (907)562.2343
Fox; (907) 361-5301
MUST PE CO'NIP4E-I'E.D BY WATER SUPPLIER
© PUBLIC WATER SYSTEM I.D. q �_
IS( PRIVATZ WATER SYSTEM
r0 '7end lnvulee
S�"'
Collected
Q...r a�nam nunulomwnv �C �;�—i
'.`."f
to
�0�t, vMOa/
Nl �umoer
NWIr1( I,MW u�l•T��
lir! )Ulr
Zia VW.
0 Send Routu O Send lrrvoke
LIMO)'?"ti.
I 4110%AGCItr —1 �-- —
SAMPLE DATE:./J I
Month Day Year
SAMPLE TYPE:
Routine 0 Treated \Yater
q Repeat Sample (for routine Sample 0 Untreated Water
with lab ref, no. � )
* Special Purpose
SA:NIPLE LOCATION
/_01-6 6 t✓,C Z
Time
Collected
Collected
By
L
Pica,.
T'0 BE CONSPLETFD BY LABORZ-�TOKY
Analysis shows this \Fater S.k'04E to be;
Salisfactary
d Unsatisractory
4 Staple over 30 hours old, results may
be unreliable
o Sample too long in transit; sample should
no( be over 43 hours old at examination
to indicat, reliable resulu. Please send
new sample via special do .very mail.
Date Received 2
Time Received
Analysis Began
Analvti(;al IiMc(hod; W Membrane Filter
0 IVIMO•1\tUO
' dumber of c010nie5/100 ml.
Result' Analyst
(96.6 05 -
Anch Fbls Jun El
Far%
ogre: -- Tine:
Client notified of unsntisfaelory results:
0 T ❑
Phenol Spoke 'Aith Faxc
Dutc: Tin,.:
I3ACTEPIOLOGICAL WATER ANALYSIS RECORD
1INI1N10.1%M; Reful(: Total Coliform g', C0/i
Mcrnm rano Filter: Oireel Count _ _ Q Co19nie3/100 ml
Verification; LTB BGB __^ �COLIFIV-h�_ - Ys'rC•tw.r'. r,C"o"
Fecal Coliform Confirmation °"
Final I\tcmbranc Filter Results Coliro mf100 ml
Reported By /`f t V bate f2 �'C1G Time t hrs
r ---�
Comments:
r©1_SGS M@r*+ber of the SCS Group (50eiCI6 GCn Qrd IE de Surveillance)
12/1b/`J6 11:155 1;166 t5l HMLHUKHbt - yb'lby611211 NU.755 We?
ME Environmental Services Inc.
AL u
ME Ref.N
966504001
Client Name
S & S Engineering
Project Name/#
L6 B2 Groll
Client Sample ID
L6 H2 Groll
Matrix
Drinking Water
Client POl/
Printed Date/Time 12/13/96 17:01
Collected Date/Tune 12/10/96 11;00
Received DatelTline 12/10/96 13:00
Technical Director: Stephen C. Ede
Ortleced By
PWSID a�
Released By 4 -C f
Sample ReOuurks:
Sample collected by: Ray
Parameter
Nitrate -N
total Coliform
Allowable Prep Analysis
Results POL Units Method Limits Date Date Init
0.605 0.100 mg/L SM18 4500-NO3F 10 max 12/13/96 WEP
0 0 col/100mL SM16 922Z0 12/10/96 WEP
-43-ob we ooH' 1\�L SNMPL-�L L>