Loading...
HomeMy WebLinkAboutT12N R3W SEC 22 LT 14 PTN S2 & W30'Onsite File #015-141-09 · ' Municipality of Anchorage Page / of '~ DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: .~ W ~ C~0~-7 PIDNumber: O~3--lql Name~c~'¢,~e ~O~ ~ Wastewater System: ~New D Upgrade ~o o'~/~x ~d, ~¢4 ¢9~/ ABSORPTION FIELD NO. of Bedrooms: Phone: ~ ~ - /O ~ ~ ~ ~ Deep Trench ~ Shallow Trench ~ Bed D Mound ~ Other LEGAL DESCRIPTION so, Rating: Totat Depth from original grade: Lot ~ I/~~0 ~ / ¢ Block: Subdiv~ion: Depth to pipe bottom~,from~original grade: Ft Gravel depth beneath~, ] pipe Ft. Township: [Range: I section: Fill added above origin. I grade: Gravel length: Number of lines; J Distance between WELL: ~ New ~ Upgrade Gravel width: ~ '~ Ft JI -- Ft. Classification (Private. A.B,C): Total Depth: Cased TO: Total absorption area: Pipe material; ~ _~ / ~ Driller: ~'~ P~lh%3 Date~/~/~)Drilled: StaticWater Leve[:~ ~Ft. Installer:~¢ Date installed:~/ /~/ ~¢ Yield: Pump Set at:~ Casing Height Above Ground: TANK SEPARATION DISTANCES ~ Septic a Holding ~ S.T.E.P. To Septic Absorption LiQ Holding Public/Private Manufacturer: Cap~city in gaJloRs: From Tank Field Station Tank Sewer Lines ~C~Of~¢ ¢ T~ ~ [ ~ 0 ~ Material: Number of Compa~ments: Surface Water > ~OO' > ~ .... LIFT STATION ~. ~. Lot Size in gallons:J Manufacturer: Foundation Cudain _ _ Pump Make & Model ~ Electrical Inspections pedormed by: Drain Remarks: BENCH MARK Location and Description: J Assumed Elevation: ENGINEER'S SEAL Inspections performed by: F(¢ ~¢ %¢~4 ~c Dates: 1st ff//ffgYq ~.., ..... Depa~ment of Health and Human Se~ices approval ::::{;. ~, c~:-~5~9 72-013 (Rev. 9/91) MOA 25 PERMIT NO: SW990057 PID NO: 015-141-09 SWING TIES: FROM: COR, "A" COR. "B' TO: TR. C.O. "D" 40.5' 49' TR. M.T. "E" 42.5' 50' TR. C.O. "F" 81' 64' DBL. C.O. "G" 67' 40' S.T.C.O. "H" 64.5' 35' S.T.C.O. 'T' 62' 29' WELL TBM 1000 GALLON 'T' SEPTIC TANK PAGE 2 OF 2 PLAN VIEW SCALE: t" = 30' SITE FOR SIM. ./.~-- REPL, TRENCH 40' LONG SOIL ABS. TRENCH W. 5.1' GVL. BELOW PIPE DRIG. GROUND ELEV. LONG SOIL ABS. TRENCH 5.1' GRAVEL BELOW PIPE BOTTOM TRENCH ELEV. 82.C T.H. #2 BOTTOM M.T. i~ELEV. 75.5 DRY 6/16/99 PROFILE VIEW NOT TO SCALE 92.1 1000 GALLON INV. SEPTIC TANK 92.4 S 112, LOT 14, SEC 22, TI2N, R3W, S.M. SEPTIC SYSTEM INSTALLATION AS-BUILT INSPECTION REPORT FLATTOP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAOE, ALASKA 99516 SCALE:AS NOTED DRAWN BY TFM SEPTEMBER, 1999 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Sfreet, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON.SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Apr 13, 1999 Expiration Date: Apr 12, 2000 Permit Number: SW990057 Legal Description: T12N R3W SEC 22 LT 14 PTN S2 & W30' Design Engineer: 0019 Flattop Technical Services Owner Name: Eugene & Dolores Roguszka Owner Address: 4320 O'Malley Road Anchorage, AK 99516- ParcellD: 015-141-09 Site Address: 004400 OMALLEY RD Lot Size: 97350 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chaptem 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October '15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. With the issuance of this wastewater disposal system permit, the exploratory well permit #SW990035 can now be considered a regular well permit. If there are any questions about this permit, please call the On-site program at 343-4744. Received By:/. ('/ :F TTOP TE CHNICA : . SERYICES! ,. CIVIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. J. 4530 ECHO ST. PH: (907) 345-1355 ANCHORAGE, ALASKA 99516 April 5, 1999 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: The purpose of this letter is to provide the required design narrative in support of our application for a permit to construct wastewater disposal facilities on the South ½ of Government Lot 14, Section 22,. T12N, R3W, S.M. I understand that a well drilling permit has recently been issued for this lot. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed for your review. The property owner, Eugene Roguszka, needs the septic permit as soon as possible so that he can file for Iris building permit. The proposed system will be constructed in the vicinity of test hole #2. As can be seen from the soil log, the native material below 2 feet is a gravelly sand with a measured perc rate of less than one minute per inch. Despite the rapid measured perc rate, no additional sand filter should be required, because the in-situ native sand will fulfill the role ora sand filter. Using the soil application rate of 1.2 gpd/~q, ft. specified in the wastewater ordinance for soils with perc rates faster than 5 minutes per inch, this 3- bedroom residence requires a total absorption area of(3 x 150)/1.2 = 375 square feet. The proposed 40 foot long trench design with 5 feet of effective gravel depth has a total absorption area of 400 square feet. The topography of the lot in the area of the proposed septic system construction slopes down towards the southeast at 5 - 10%. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on reserved space-surface and subsurface, or on drainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. OIMALLEY ROAD Q- TAYLOR S/D LLI LOT 15, SECTION 22, / ~ TRACT "C" ,' / WELL 6o/0 ~'~ ~T.H. ' REPLACEMENT TRENCH 0' NO SOIl ABS. IRENCH .'/ W. §.§' GV/BETW. 2' & 7.§' B.G.L. SEPTIC $oU'rH ~12, LOT '14, SYSTEM SEC. 22, T'12~, R3VV, $.M. COT ~8 (VACANT) kOT 1~ (V^C^NT) ~ .o°" ° * '~' ,/'",~Z ~ PROPOSED SEPTIC SYSTEM DRAWN BY TFM ~ , %Th~OOO~ F. ~OOR~ &' Aq, 14530 ECHO STREET ~",~;.?o,. C1~-3589 ,.,~,.~ ANCHORAGE, ALASKA 99516 MARCH, 1999 . , ~:~,~;~.:- ' ~g/r~ ' ALL LOCATIONS SHOWN ARE APPROXIMATE. 4" DIA. D-3034 WASTE LINE FROM HOUSE 1000 GALLON SEPTIC TANK -- DOUBLE C.O. / 4" DIA. F-810 PERF PIPE / '~ 40' LONG SOIL ABSORPTION TRENCH WITH 5' GRAVEL BELOW DIST. PIPE BETWEEN 2.5' & 7.5' B,G.L PLAN VIEW SCALE: 1" = 10' - 0" 3 1 cLEANouT -- MONITOR TUBE MOUND BACKFILL 12" ~AL GROUND FILTER FABRIC F-810 PERF. PIPE - 2 1/2" SEWER GRAVEL BOTTOM OF EXCAVATION SECTION "A" - "A" SCALE: 1" = 5' - 0" S 1/2, LOT 14, SEC. 22, T12N, R3W, S.M. SEPTIC SYSTEM DESIGN PLAN AND CROSS-SECTION FLATTOP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAGE, AK, 99516 SCALE: AS SHOWN DRAWN BY: TFM MARCH, I999 Flattop Technical Services 14530 Echo Street, Anchorage, AK 99516 Phone (907) 345-1355 South ½ of Lot 14, Section 22, T12N, R3W, S.M. O'Malley Road Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope ofthe project consists ofinstalling a 1000 gallon septic tank followed by a 40 foot long soil absorption trench containing a total of 5.5 feet of sewer gravel. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform to Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 2.0 Septic Tank: 2.1 The new 1000 gallon, 2 compartment septic tank shall be Municipally approved and shall be set level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.2 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be installed within 5 feet downstrean~ of the septic tank. 3.0 Soil absorption system: 3. I The soil absorption system shall be constructed by excavating a 40 foot long trench to a depth of 7.5 feet below ground level, with the long axis parallel to the natural contour of the land. 3.2 The bottom of the excavation shall be level. Because the native material at the site is a clean gravelly sand, there is a good chance that the sidewalls of the trench will tend to slough in as the trench is being excavated. This will probably mean that significantly more sewer gravel will be needed to fill the excavation than in a typical trench. 3.3 A total of 5.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with the perforated distribution pipes laid level such that the pipe inverts are no less than 5.0 feet above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel before backfilling with 3 feet of sandy material from the excavation. 3.6 The top surface of the cover material shall be raised 12 inches higher than the original grade, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3: I. 3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and seed to promote rapid revegetation of all areas disturbed by the construction. 4.0 Inspections: 4.1 A minimum of 4 engineering inspections will be required during the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and grading is complete. The septic tm~k requires one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. TEST HOLE LEGAL DESCRIPTION: DATEPERFORMED: PERFORMED FOR: DEPTH (fee~ 11- 12- 13- FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST South 1/2, Gov't. Lot 14, Section 22, T12N, R3W, S.M. March 29, 1999 Eugene Roguszka Pt. SM Yellowish sandyloam (frozen) SW/GW Clean gravelly sand Dry, unstable sidewalls Many cobbles to 5" diameter SLOPE Depth to Groundwater Date No ~roundwater 3/29/99 Monitor tube dry 4/5/99 SITE PLAN TRACT"C" OF N 1/2, LOT 14 ~7 S 112, LOI ~4, $1:G 22 '1'12~, RSW, S.M. Date Reading Clock Net Time Percometer Net Drop Time (minutes) Reading (inches) 3/29 5 gallon presoak 11:00:30 24 1/2 Perc hole dry 11:01:15 0.75 17.25 7.25 PERCOLATION RATE <<1 (minutes/inch) PERC HOLE DIAMETER 6 TEST RUN BE'FWEEN 3.0 FTAND 3.5 FT COMMENTS: During perc test the water depth never reached 12 inches as 5 gallons was added at 4 gpm, and all the water was completely absorbed in 45 seconds. No sand filter needed because the native material is predominantly sand. PERFORMED BY FLATTOPTECHNICALSERVICES. i ,'~,~-.-~ ~ CERTIFYTHATTHISTESTWASPERFORMEDIN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ITEST HOLE LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH (feet) 1 3 4 5- 6 7- FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST South 1/2, Gov't. Lot 14, Section 22, T12N, R3W, S.M. March 29, 1999 Eugene Roquszka Pt. SLOPE SM Yellowish sandy loam (frozen) SW Clean, somewhat gravelly sand Dry, sidewalls unstable Less gravel and cobbles than in T.H. #1 LOT 15 TRACT "C" OF N 1/2, LOT 14 S 1/2, LOT 14, SEC 22 T12N, R3W, S.M. Depth to Groundwater Date No qroundwater 3~29~99 Monitor tube dry 4/5/99 Clock Net Time Percometer Net Drop Date Reading Time (minutes) Reading (inches) 3/29 5 gallon presoak 11:59:40 25 1/4 Perc hole dry 12:00:20 0.67 17 1/4 8 PERCOLATION RATE <<1 (minutes/inch) PERC HOLE DIAMETER 6 TEST RUN BETWEEN 4.0 FTAND 4.5 FT COMMENTS: This sand material is so clean that 5 gallons of water poured into the perc hole at 4 gpm never reached a depth of 12 inches, and all the water was completely absorbed after 40 seconds. No sand fitter needed because the native material is sand. PERFORMEDSY FLA3-1'OPTECHNICALSERVICES. I ::~,.~,~ ~ CERTIFYTHATTHISTESTWASPERFORMEDIN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: M-W DRILLING, Inc. P.O, Box 110378 · 10330 Old Seward Highway (907) 349-8535 ANCHORAGE, ALASKA 99511 PERMIT # SW99035 DRILLING LOG ~ell Owner ~o~tion (address of'. Township, Range, Section, if known; or distance main roBcl T,,'~qTM 14; ~('q~T(']N' ~.. rPl~; I?qW; .qM: A4~ ~IMAT,T,~V ANCHORAGE, ALASKA Size of casing 6" Depth of Hole 2 8 2 feet Cased to 2 8 0.5 feet Static water level 2 3 0 ft. (~i~ ~low) land surface, Finish of well (check one) Screen ( ); Perforated ( y ).. Describe screen or perforation N~ A~: Well pumping test at 1.5 ga~,~,'~s 13~' (~; of drawdown from static l~vel, open end ( X ); (minute) for 1 hours with 100% ft. Date of completion 05 APRIL, 1 9,99 , Depth in feet from ground surface WELL LOG Give d~lls of formations penetrated, size of material, color and hardness 0 TO 2 2 TO 6 6 TO 45 45 TO 56 56 TO 115 115 TO 121 121 TO. 140 140 TO 143 143 TO. 148 148_TO 217 8~1 BROWN GPLAVI~II,: SILTY O~: SILTY. CLAYEY ; SI~'~R~TM ;,~,' , ,~-- CLAY: SILTY, GRAVELLY 'GRAVEL: SILTY COARSE GRAVEL: SILTY, SANDY~ WET 223 ,TO. 229 GRAVEL: SILTY, CLAYEY 229 TO 260 · GRAVEL: SILTY 260 TO 263 COARSE GRAVEL: $ILTY~ WET 263 TO 282 GRAVEL: SILTY~ SLIGHTLY CLAYEY~ WATERREARING L--CUSTOMER MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WATER SUPPLY PERMIT Initial Date issued: Mar 18, 1999 Expiration Date: Mar 17, 2000 Permit Number: SW990035 Legal Description: T12N R3W SEC 22 LT 14 PTN S2 & W30' Design Engineer: 0000 None Required Owner Name: Eugene & Dolores Roguszka Owner Address: 4320 O'Malley Road Anchorage, AK 99516- Parcel ID: 015-141-09 Site Address: 004400 OMALLEY RD Lot Size: 97350 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special previsions. This permit is for an exploratory well only. If water production is determined to be satisfactory the well must be temporarily decomissioned as per AMC 15.55.01~0.J until a permitted wastewater disposal system is constructed. If the water production is found to be insufficient the well must be permanantly decomissioned as per AMC 15.55.060.J. A well log must be turned into the Department within 60 days of drilling in addition to a statement regarding the decomissioning of the well (ie. permanant, temporary) including intended acitons for wastewater disposal. Date: O! ,' OAD LOT 9URVEY OE:RTIFIOATION I he~ e~/cert,fy that I hove ~ur ~eyed ,he ~ s~n ~ ~ri~ in ~1~ ~ th~ ~e are ~ r~a~, utili~ li~s ~ ~her vlsiUe Prepered I~: R. £. BUTTON Reg/ster~d £ond Surveyor 519 · Eighth Ave. AncborogetAIoska 99501 /floc LEGEND I~ = Brass col:~oed ~ recovered o -' iron p~pe ond/o~ rebor recovered o : 2x2 h~b~ rock recovered · = ~/8"x~O"rebor ~.-,t this survey ~w~$T ~ F~ OF T~ Al ~ OF LOT I~ ~ ~nchoroge Recording District, Alaska LOT SURVEY CERTIFICATION ~oo,e /"~100' ~ef. 2656 F'e' N°'~D-43 · ¢ % R. L BL, non ."' "'? LEGEND Br~ or Aluminum ceded me~me~t rjcovered 0 I~ Cpa ancot rear recovered 2x~ hub ~teek recovared J 5/8'x ~' rebar se~ this surv~ Prepared by; ~. £. 8UFFON Registered l. and Surveyor (907)2Y9- ~ZO0 519 W. Eighth Ave. Anc~a~ ~/oeko 9~501 0',4 ,A/ / E'7" ~OAD ~OT /~ ? ,350' LOT 4°43 I 330' Lot /,~ , Block 3~'C. 2~, ~/~/k/o,/~. 3 Wo, S.A~.~ ALA.S/~A Anchorage Recording District, Aloska LOT SURVEY CERTIFICATION .~ LOT/4 LEGEND o Iron pipe ond/or reb~r recovered ~ 2 x~ hub ~ rock recovered 2636 Property of:z-- //0 ~ 6o V•f ;�� Development Services Department ` On -Site Water &Wastewater Section - Certificate of On -Site Systems Approval Parcel I.D. 015-141-09 1. GENERAL INFORMATION Complete legal description f7plyl-Ils Phone: 907-343-7904 Fax: 907-343-7997 Expiration Date: 0,� D T12N R3W SEC 22 LT 14 PTN S2 & W30' Location (site address) 4400 O'Malley Road Anchorage, AK Current property owner(s) Eugene RogusZka Day phone 508-864-4591 Mailing address 4400 O'Malley Road, Anchorage, AK 99507 Real estate agent Mary Cox 2. TYPE OF DWELLING: Fx] Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 907-440-9820 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well Fx� Private Septic FE Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ dssU — ` Waiver Fee $ Date of Payment i ' LO\ r Date of Payment Receipt Number q `i ('0 Receipt Number COSA# ne;>c-\Ak15 Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage AK 99503 Engineer's Printed Name Michael E. Anderson, P.E. Date 11/7/19 6. DSD SIGNATURE System #1 Approved for 3 bedrooms System #2 Approved for bedrooms Disapproved Conditional approval for bedrooms, with the following stipulations: By: ju Original Certificate Date: 1 1 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Septic System Advisory Well Flow Advisory COSA Checklist blue sheet Nitrate Advisory Arsenic Advisory Other Tan x COSA Checklist yellow sheet COSA Checklist Legal Description: Parcel ID: If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test?Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date of Sample Comments __________________________________________________________________________________ B. TANK DATA Age of tank(s) years Tank type/material Measured operating fluid level in septic tank Standpipes/foundation cleanout per record drawing Date of pumping C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA ______________________ Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field Monitor tubes go to bottom of effective. If not, state depth into effective Code-required soil cover over field System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Adequacy test date Results Pass For bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min Final fluid depth in Absorption rate gpd Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies: T12N R3W SEC 22 LT 14 PTN S2 & W 30' 015-141-09 6 4/5/99 0 282 280.5 4.17 >18 FORGE ENGINEERING 11/5/19 227 10/10/19 20 SEPTIC/STEEL 47" 11/11/19 - A Plus Home Services DEEP TRENCH 6/16/99 11/5/19 3 8.6 0 3.5 850 0 154 0 450+ ✔ COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to:(Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’Yes if No ft Absorption Field on Lot > 100’Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’Yes if No ft Holding Tank > 100’Yes if No ft Animal Containment > 50’Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft From Septic/Holding Tank on Lot to:(Please enter distances if less than required) Building Foundations > 10’Yes if No ft Property Line > 5’Yes if No ft Absorption Field > 5’Yes if No ft Water Main > 10’Yes if No ft Water Service Line > 10’Yes if No ft Surface Water > 100’Yes if No ft Wells on Adjacent Lots: Private Wells > 100’Yes if No ft Community Wells > 200’Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to:(Please enter distances if less than required) Building Foundation > 10’Yes if No ft Property Line > 10’Yes if No ft Water Main > 10’Yes if No ft Water Service Line > 10’Yes if No ft Surface Water > 100’Yes if No ft If absorption field is under driveway comment below Wells on Adjacent Lots: Private Wells > 100’Yes if No ft Community Wells > 200’Yes if No ft F. ENGINEER’S COMMENTS G. ENGINEER’S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. 11/12/19 ✔✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 907-343-7904 On-Site Water and Wastewater Section Fax: 343-7997 www.muni.org/onsite Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519-6650 * www.muni.org Septic Tank Advisory Certificate of On-Site Systems Approval # OSC191531 Subdivision: T12N R3W Section 22, Lot: 14 PTN S2 & W30' The septic tank for this property is 20 years old. The average life for a steel septic tank is 20 years. Typical replacement costs range from $6,000 to $9,000. This advisory must be attached to all copies of the subject Certificate of On-Site Systems Approval. This is an example of what the metal of a 30 year old steel tank MAY look like. 100' WELL RADIUSOHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU N90° 00' 00"E 1318.68 REC. N90° 00' 00"E 329.67 REC.BASIS OF BEARINGSN00° 06' 00"W 585.00 REC.S00° 06' 00"E 330.78 CALCULATEDBY LINE EXTENSION INTERSECTN00° 06' 00"W 585.00 REC.S89° 51' 29"W 299.71 CALC. N89° 56' 42"W 330.64 MEAS. N90° 00' 00"W 329.67 REC.S00° 12' 58"E 583.60 MEAS.S89° 45' 41"E 329.46 MEAS.S00° 18' 27"E 254.90 CALC.N00° 03' 00"W 255.00 REC.N89° 57' 00"W 300.00 REC.;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;SSSSSSWETOHU OHU OHU N00° 06' 00"W 584.65 MEAS.16.0 31.940.54.56.9 4.51 1 . 32.67 . 3 32.12.015.111.2 15.2 2.114.010.7 16.3 14.0LOT 15LOT 13LOT 13DOCUMENT NO. 2016-048540-0ANCHORAGE RECORDING DISCTRICTDOCUMENT NO. 2015-022402-0 ANCHORAGE RECORDING DISCTRICT TAYLOR SUBDIVISIONPLAT #74-37LOT 14, SECTION 22TRACT 12 NORTH, RANGE 3WEST S 2' & W 30116,426 Sq. Ft. +/-4400 O'Malley Road1 Story Wood Frame HouseWith Attached 2 Car Garage25.8 47.3204.6 LOT 19 S89° 56' 42"E 30.00 CALC. 1 3 . 8 30.3PAVED DRIVEWAY℄ O'MALLEY ROAD SSSPREPARED BY:FRONTIER SURVEYS, LLC650 W. 58th AVE. SUITE E, ANCHORAGE, AK 99518907-460-1686DRAWN BY: CHECKED BY: DATE: SCALE:DRAWING ID: SHEET 1 of 11. Excepting for gross negligence, the liability for this survey shall notexceed the cost of preparing this survey. Dimensions to property linesare plus/minus 0.1ft.2. This document is created by Frontier Surveys for the purpose of a plotplan for Mary Cox, only.3. This document is based on U.S. BLM Dependent Resurvey andSubdivision of Sec. 22 Dated: 2/14/1952.4. All lot corners have been located and marked.General Notes DisclaimerLegend1. This survey complies with the ASPLS Mortgage Location Standards. The survey represents visibleimprovements and conditions at the time of the survey. This document does not constitute a boundarysurvey and is subject to any inaccuracies that a subsequent boundary survey may reveal. It is theresponsibility of the Owner to determine the existence of any easements, covenants, or restrictionwhich do no appear on the record plat. Under no circumstances should this document be used forconstruction or for establishing a boundary or fence line.S T A TEOFALASKA49THROYEVR U SDNALLANOISSEFORPDERETSIGERFrederic W. WagnerNO. LS-9946KC & FW 1" = 50ft11/20/201919-462SS11/20/2019Scale 1" = 50'AN AS-BUILT OFLOT 14, SECTION 22TRACT 12 NORTH, RANGE 3 WEST S 2' & W 30'ANCHORAGE RECORDING DISTRICT, THIRD JUDICIAL DISTRICTSTATE OF ALASKA4400 O'MALLEY ROAD ANCHORAGE, AKCONTAINING: 116,426 Sq. Ft. or 2.67 ACRES +/- (CACLCULATED)RECORD PLAT: U.S. BLM DEPENDENT RESURVEY AND SUBDIVISION OF SEC. 22 DATED: 2/14/1952ETEElectric MeterElec. PedestalTel. PedestalWellFound Alum. CapFound RebarSepticUtility PoleSignFound PipeLight PoleGas PumpsSW75'R.O.W.CULVERT EDGE OF PAVEMENT