Loading...
HomeMy WebLinkAboutT12N R3W SEC 33 LT 188 W2Rick Mystrom. Ma vor Municipality of Anchorage Department of Health and Human Services 625 "L" Street P.O. Box 196650 Anchorage. Alaska 99519-6650 http://www.ci.anchorage,ak.us August 10, 1999 Lloyd & Joanne Crow 15131 LOC LOMAN LN ANCHORAGE, AK 99516-4030 Subject: TI2N R3W SEC 33 LT 188 W2 Permit # SW980378 PID # 01828214 The subject permit #SW980378, issued by this office for a single family well and/or on-site wastewater system, is due to expire as of 9/22/99. If this is a well permit and you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If this is an on-site wastewater systm and a licensed Professional Engineer has inspected the installation, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. However a new permit can be issued free of charge for a second year if the application for the renewal is received on or before the date of expiration of the original permit for which a fee was paid. When applying for a new permit after the original permit has expired or for more than a second year, the fees are: $320.00 for an on-site wastewater permit and $120.00 for a well permit. If you have any questions, please call this office at 343-4744. Sincerely, James Cross, PE Program Manager On-site Services enc: Copy of Permit MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 995~9-6650 (907) 343-4744 ON-,SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Sep 22, 1998 Expiration Date: Sep 22, 1999 Permit Number: SW980378 Legal Description: T12N R3W SEC 33 LT 188 W2 Design Engineer: 0007 Tobben Spurkland, P.E. Owner Name: Lloyd Crow Owner Address: 15131 Loc Loman Lane Anchorage, AK 99516-4030 Parcel ID: 018-282-14 Site Address: 003801 RABBIT CREEK RD Lot Size: 54450 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special previsions. The separation distance between the STEP tank and the West property line has been waived to 0 feet. Waiver #WR980063 Issued By: Date: ,Rick Mystrom, Mayor Municipat t of Lnchoragc Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage. Alaska 99519-6650 September 22, 1998 Tobben Spurldand, P.E. 203 West 15th Ave. #203 Anchorage, AK 99501 Subject: Waiver Request for T12N, R3W, Sec 33, West ½ of Lot 188 Waiver Request #WR980063, PIE) #1 I8 282 14 Permit #SW980378 Dear Mr. Spurldand: Your request for a waiver of the required 10 feet horizontal separation from the S.T.E.P. tank to a property line has been approved. The approved separation distance is 0.0 feet. This waiver approval applies to the existing S.T.E.P. tank to property line separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from tNs department. If there are any further concerns or questions regarding this waiver, please call our oftlce at 343-4744. Sincerely, Civil Engineer On-Site Water Quality Program MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-site Services Section Date Received: Legal Description: Engineer: Waiver Review Worksheet Permit Applicant: L\OfA~ Waiver'Requested: ~2~ ~-~"~ Criteria: 2. 1. Geology: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: Special Conditions: Points: 3. Other: Waiver is Granted: ~/ Waiver is NOT Granted: List Conditions or Reasons for above: Date: Rec #: O~O~q Amount: Name of Reviewer $ \\~' Date Paid: q'[~ '~ ToSP jP LAND 203 W lSth. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN W ~ LOT 188 SEC 33 T12N R3W LLOYD CROW Municipality of Anchorage Department of Health and Social Services 820 1 Street Anchorage, Alaska 99501 We am submitting an application for the installation septic system upgrade for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: Ground Water ~ 9 fi during breakup. Use 5- wide Standard Trench Soil Rating. From Testhole August 4, 1998 7 min/in = 0.8 gal per sq.lVday No. of Bedrooms 4 Required Area per Bedroom: 150/0.8 = 187.5 sq.fi. Total area required: 187.5 x 4 = 750 sqfi Use 3 feet of rock. Reduction factor .58 Required Length: 750 x .58 / 5 - 87 fi SYSTEM CONFIGURATION STANDARD 5-WIDE TRENCH TOTAL LENGTH 90 FT TOTAL WIDTH 5 FT TOTAL DEPTH 5 FT ROCK DEPTH 3 FT COVER 3 FT SEPTICTANK 1500 GAL STEP The installation of this septic system will not prevent wells from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. We are requesting a lot line waiver for the STEP tank. The topography of the lot prevents a standard tank to be installed outside of the 100 foot well radius. The cover over the tank would be more than ten feet if located away from the lot line. N SCALE: l' ~ 100 FT, Ltl? 187 ~,, r- ...'~-~';¢ x ~ , ...' ............... ~ ~;' ... '..~ ~ ~ VACANT ~,.....~.....~.~z~_~_ ',....~ ...~~ ~ **~?~............~5~ ~ £1/£ -- -- ~ NelJ TOEEEN SPURKLAND P.E, 205 Id 15TH. AVENUE ANDN. AK. 9950! (907) 279.$916 Wl/2 LOT 188 SEC. 33, T12N R3W LLOYD CROW 15151 LOC LOMAN LANE SEPTIC SYSTEM DESIGN DATE: S£PL 14, 1998 SHEET: !/5 GRID: 5155 PERNIT # SV98XXXX P[D fl 018-28:°-14 1.500 OAL STEP STANDARD 5-WIDE TRENCHES TOTAL LENOTH 90 FT T~TA~_D£OZ. ~ Fx_ -- EFFECTIVE ROCK DEPTH $ FT COVER $ FT I ABANDON ~XISE I TRENCH N f 25 ~ABANDON~ ~)- ~e11 I I _ Well TOBBEN SPURKLAND P.E. 205 W 15TH. AVENUE ANCH. AK. 99501 (907) 279-3916 IIWl/2 LOT 188 SEC. 33, T12N R3~f LLOYD CROW 15151 LOC LO/dAN LANE SEPtiC SYSTE/d DES/ON DATE: SEPT. 14, 1998 SHEEt 2/5 GRID: 5155 PERMI~ # SW98XXXX PIE # 0~8-282 14 23331882,DW0 S ?ANDAI~D 5- F/IDE ff~EN£HES 90' Long 5' Deep 3,0' Se~/er rock 3' Cover (INSULATE) NZI SCALE / 3' Cover o 1500 5AL STEP TANK 4" ?nsulotion 3.0 Pt oF Sepi. ic P~ock Effective NB SCALE 1500 6AL STEP TANK TOBBEN SPURKLAND P.E, 203 ~dlSth Ave Anchopoge Ak 99501 PERMIT// Sl'F9800X.,,v 15151 LOC LO,VAN LANE LLOYD CROP/ SEPTIC SYSTEM DESIGN DATE: SEPL l& 1998 SHEET: 3~'3 GRID: 3]35 2533188~DWG PARCEL ID Z7 XX Municipality of Anchorage DEPARTMENT OF ~-'EALTH & HUMAN SERVICES 825 "L" Street, Ar'chorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: L LEGAL DESCRIPTION: 1 4- 5- 6- 7- 8- 10- 11 13- 14- 15- 16- 17- 18- 19- 20- O P-'&,~/I; c, .S Township, Range, Section: SLOPE WAS GROUND WATER ENCOUNTERED? SITE PLAN iF YES, AT WHAT DEP rH? OepthtoWaterAIter JJT~- Date: Reading Date Gross Net Depth to Net PERCOLATION RATE __ TES~ RUN BETWEEN (minutes/inch} PERC HOLE DIAMETER FTAND .~ FT PERFORMED BY: J' ~'' ' ~ ~'~, CERTIFY THAT..~./THIS!TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUH'ELINES IN EFFECT ON THIS DATE. DATE: 0/17.,/ ~--~ 72-008 (Rev. 4/85) ANCHORAGE AREA BORi GH Depsrtment of EnvironmentsI QusIKy 3330 C Street Anchorsge, AIssk8 gus03 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME ~'.~2/4~, ~,?~/~_.~' MAILING ADDRESS,~''///~//~,~'~/__2~, ...~/~/~/~ PHONE '~ '~/"~'~-(~-~'" LOCATION /~'~'~'~ ¢~/~', /~'~'~-"~¢ LEGAL DESCRIPTION ~':'~///~' SEPTIC TANK: DISTANCE NUMBER OF FROM WELL///~, / MANUFACTURER ~//~/-////~'// MATERIA-L/~/~"~?//~-~'-~COMPARTMENTS ~::"/~- IN~,:J~E~.EN GT H -~ / ~" / INSIDE WIDTH ~/ ~' LIQUID DEPTH LIQUID CAPACITY~/~-,/~/~GALLONS. TILE DRAIN FIELD: / ,///--,~,~.,~/-, TOTAL LENGTH DISTANCE FROM WELL~-/~ ~' FOUNDATION ¢,,~ .NEAREST LOT LINE.~__~/~ ~'~/~'~-- OF LINES NUMBER OF LINES ~,///~-~ DISTANCE BETWEEN LINES /~//~ TRENCH WIDTH~'~'~¢ IN. TOTAL EFFECTIVE ABSORPTION AREA '~'~%~ SQ. FT, LENGTH OF EACH LINE DEPTH: TOP OF TILE TO FINISH GRADE ~/ / MATERIAL BENEATH TILE ~'~'~' IN. ABOVE TILE ~ IN. WELL: BUILDING FOUNDATION/~ CESSPOO L~/ APPROVED CONSTRUCTION ~'z'~/tL //~'-- /~/'/g'¢'"~'~//~'/// DEPTH ~[?/~;C DISTANCE FROM: NEAREST NEAREST ~_ TANK~/~SEPTIC / SEEPAGE .-) (~ LOT LINE /~ ~ SEWER LINE ~ , SYSTEM /~ -' -- OTHER SOURCES ~///' ~//~/~ DISAPPROVED REMARKS ~/~/~_~,~/~//~2~-~ ~¢~'///J~Z~ DISTANCES: INSTALLED BY: SEWER LINE DEPTH:, PIPE MATERIAL: LOT SLOPE: ..~r ~.~, REMARKS: //J/'~). ,./J/:e,"~ ~?~e" DIAGRAM OF SYSTEM Form EQ-032 DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE [] NEW D & B GENERAL, INC. 349-6965 [~]UPGRADE MAILING ADDRESS P.O. BOX 10-1349 ANCHORAGE, AK. 99511 LEGAL DESCRIPTION W ½ L188 SEC 35 T12N R3W LOCATION NO. OF BEDROOMS LOCLO~AN AND RABBIT CREEK 5 J Well I AbsorlStion area Dwelling PERMIT NO. DISTANCE TO: T03 ' 12 ' 60 ' 820423 F- ~ Manufacturer Material No. of compartments ~< GREER STL 2 ~ I- Liq. capacity in galJons Inside length Width Liquid depth 750 IF HOMEMADE: '& ~ DISTANCE TO: Well Dwelling PERMIT NO.  DISTANCE TO: Well 130 t + Foundation 90 ~ + Nearest Jot line 50 ~ PERMIT NO, 820423 ~ ~ ~ No. of lines ~ Length of each line ~0 ~ 72 Total effective absor~rea ~ DISTANCE TO: OTHER PIPE MATERIALS I' PVC/CAST SOl L TEST RATING 225 INSTAELER D &'B GENERAL, INC. ":C No. 2100 - E ' ~ '~.... OdT. 74. lq7N _'~ APPROVED DATE 72-013 (Rev. 3/78) F'ER!:d Z T FIPPL I CFINT LOCF!TION LEGFIL DEB GENERRL INC: F'O BOX :1.E~-i. 349 E~95:1.:1. LOCL. OHFIN & F..'RBBIT CREEK RE:, M2 L~L88 S:~:2. T'l_2NR:ii:t4 LOT Si~E FEET T'?'F'E OF SOIL. FIE~SORPTION SYSTEM ZS: TRENCH MRXi'MUM NUMBER OF BEDROOMS SOiL RRT.!NG 4:56! FT,-.'BR)= 2.'Z-:5 THE RE:g!U:EF..'EC, SIZE OF THE SOIL RBSORF'TZON S¥STEH IS: THE LENGTH DIMENSION IS 'THE LENGTH ,:;IN FEET) OF THE TRENCH OR DRFilNFIELD. 'THE E:,EPTH OF R TRENCH OR P);]" IS THE D!STRNCE BETP~EEN THE SURFFtCE: OF THE GRCHJND R[4P THE BOTTOI','! OF' THE EXCR',,,'F~TZON (IN FEET>. THERE IS NO SET 14tDTH FOR TRENCHES. 'THE GRRVEL. DEPTH IS 'FHE HINiP1UH DEF:']"H OF GRR',,,'EL 8ETI.,.IEEN THE OUTFFILL PIPE FIND THE BOTTOI'd OF THE EXCR',,,'R'f'ZON ,.'.'~N FEET). PERP'I.IT RPPLICFIN-F HF~S THE RESPONSiB!LIT¥ 'TO INFORM ]'HIS; DEP"'FiRTMENT DURING THE INSTRLLRTZON INSF'EC:TION$ OF R!'.,W [4ELLS FiD..fRCEN'f' TO TPIIS PROPERT'.~' RN[:, THE NUMBER OF RESi'DENCE'.'5 THRT THE !..IELL [4IL. L SEF.:',/E. E:FICKFILLZNG OF' FtN'T' S'-FSTEM P!tTHOUT FIbifiL ZNE;PEC'1"ZON RN£:, RPPROVflL.. B'¢ THZS DEF'RP".tT!'IENT 1.4ZLL BE SUB.'rEC:T TO PROSEECUTION. MINZMUP! DISTRNCE BE"F~.qEEN R [4ELL FIND Fllq'.¢ ON-SITE SEkIRGE DiSPOSRL S"r'E;TEt'd IS :L(.i~ FEET FOR I-~ F'RI'..,'FITE !.4ELL OR ::L5£~ TO ;2E~C.'~ FEET FROH Fi PUE~LIC 14ELL [:,EF:'E~.,!E:,ING UF'ON THE] T'T'PE OF PUBLIC !,,,!EL.L. I"!Ii".ilMUH DISTRi",ICE FIE:OH FI PRZVFITE I4EL.L TO F'~ PR'_r',,,'RTE SE!.,.1ER L. ZNE :IS 25 FEET P,!'.,!L;, I'O Fl C:Cd"!PILIN:ET'¢ SE!..!EI:~'. LINE IS 'TEl FEET. OTHEF: F:EI;!UIREHEhtTS h!R'T' RF'PL'¢. SPEC:ZFZCRTiOI"4S RI",ID CONSTRUCTION E:,I!:ILSRF~!"!S FtF4:E FtVRZLRBLE TO INSURE PF.:OF'EF..: ZNS']'RL.LRTZON. ! CERTIFY THRT ±: i Fif"l FRt"IZLIRR !4ITH THE REE:!LliREHENTS FOR ON-SiTE SEIqEIE'.S RND i,!ELL.S RS SET FORTH Eft' THE MUNZC;EPRL. ZT'¢ OF Fff.,iCHORRGE. 2: I !,.!I!_L INSTRLL THE S'¢STEM IN RE:E:ORD!~NCE P.!ITH THE CODES. ~:: Z LI!'.4E:,ERSTRND THF!T THE ON-.E;!TE E;EI,.IER S;'¢STEM f,!FI'¢ RE6~LIZRE E~.,I!~..R~E'.E~EI~!E:f..IT iF THE RESIDENCE ZS RE!'dODELED TO INCLUDE HORE THRH 5 BED~'.OO!',IS. ...................... ~:~EE' GENE~.F!L Z NC: GreaTer ANChorage Area BorOugh ~.'oo ~'~' DEPARTMENT Of ENVIRONMENTAL QUALITY PER IT NOT.~ 3330 "C" STREET ANCHORAGE, ALASKA 99503 /;7~ ~' ? TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM m APPLICATION AND PERMIT COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. EACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK SEEPAGE PIT TO NEAREST LOT LINE. WELL TO SEPTIC TANK /~O ~ DRAIN FIELD WATER MAIN TO SEPTIC TANK SEEPAGE PIT ~ TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UND]STURBeD SOIL, 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. LICENSED DESIGNER I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE ~-~ SOILS LOG PEROI,ATION I 4. 1 This form reports:-' SoilsTo~.)< Percolation test L._/' GREATER ANCtlORAGE AREA B'~uk[)U~/ Department of Environmental Quality 3330 "C" Street Anchorage, Alaska 99503 Date Perfor,,,:d f_2?_f~] z~_[/ Depth Feet 1~ Was ground water encountered? If yes, at what depth? Reading Date Gross Time Net Time F---pLh to-- _,. __.__._._.._._____-- ................. ~[i-n u t e-. .... Percolation rate -Proposed installation: Seepage Pit Drain Field Inlet . Depth~'~t~F~)it or trench Depth of ...................... Perforaed By.~ ~.~--~ Certified By:, EQ-040 (6/74) Test Pit on Ten Year Old Seepage Pit Owner: William Davis Box 480 SRA Anchorage, Alaska 344-5854 Location: Soil Sample: DeArmoun and Loc Loman (northeast corner) w 1/2 lot 188, sec 33, T12NR3W 225 Conditions: 2 first 4' silty sand & gravel 3 - soil 4 -_- depth 5 in feet 6' - ~ remaining depth silty sand 7' -- ~ gravel with blue clay mixture. , ~ '. "~ 4,~ .~ .,~8 .~' ,, ... ,'./:; '. %, ~7Z-~7 New Septic System approved 10/16/74. 1,O00 gallon septic tank and 70' of drainfield put in with extremely good backfill. By Robert Neale MUNICIPALITY OF ANCHORAGE i Development Services Department �\ Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 018-282-14-000 Expiration Date: 9/17/2025 Legal description T12N R3W SEC 33 LT 188 W2 Site address 15131 LOC LOMAN LN Anchorage AK 99516 Current property owner(s) CROW LLOYD & JOANNE V X The On-site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: M Original Certificate Date: 11/21/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory X Tank Age Advisory X Arsenic Advisory Other COSA Approval—June 2022 MUNICIPALITY OF ANCHORAGE r 1 Development Services Department _J Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 018-282-14 Complete legal description T12N R3W SEC 33 LOT 188 W2 Location (site address) 15131 LOC LOMAN LANE, ANCHORAGE, AK 99516 Current property owner(s) CROW LLOYD & JOANNE Day phone 2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS 3. TYPE OF WATER SUPPLY: ® Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ® Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 26 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed ❑ Deep Trench ® Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ SQL Date of Payment Z COSA # S C 2 y 1-0 9 Waiver Fee $ Date of Payment Waiver # COSA Application.doc COSA Checklist.docx COSA Checklist Legal Description: T12N R3W SEC 33 LOT 188 W2 Parcel ID: 018-282-14 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled UNKNOWN Total depth UNKNOWN ft Cased to UNKNOWN ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) *18+ in. Date of flow test for COSA 9/20/24 Static water level at beginning of test 32 ft. Well production at time of test 3 gpm Water storage tank volume NONE gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate 5.30 mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date 9/20/24 Comments *Casing height from the bottom floor of cement well pit with sump pump. The well extends several feet above bottom of this cement floor. The top of the well is approximately 4’+ below exterior grade. B. TANK DATA Measured operating fluid level in septic tank *NA Date of pumping 9/17/24 Required maintenance completed, if AWWTS Comments: *STEP / FLOATS C. LIFT STATION Required maintenance completed Age of lift station 26 years Lift station material STEEL Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 10/22/1998 ALL standpipes present per record drawing* Total measured depth from existing grade 6 ft (max) Measured depth to pipe invert from grade NA ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes (MT) go to bottom of effective. (ED) If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) N If yes, enter date Adequacy test date 9/20/24 Results Pass (South Trench / North Trench) Fluid depth prior to test 23 / 7 in Water added 600 gal New fluid depth 28 / 30 in Elapsed time 1440 min Final fluid depth 22 / 5 in Absorption rate 600 gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) 36 / 36 in (MOA 3’ ED) Effective depth used 22 / 5 in (Final Fluid Depth) Effective depth (ED) remaining 14 / 31 in Comments/Deficiencies: *No foundation cleanout was found & the owner has never seen. Approximate total measured depths from existing grade. ED per elevation measured shots, visual observations, MOA records & appears approximate. COSA Checklist.docx E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No *0 ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F. ENGINEER’S COMMENTS *MOA WAIVER - #WR980063 G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm FIRST WATER CONSULTING Phone 907-350-9566 Engineer’s Printed Name CURTIS HUFFMAN, PE Date 11/19/2024 Comments: This investigation was completed in compliance with MOA guidelines, regulations, and best industry practices / methods. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes in land use, local soil characteristics, groundwater levels that may fluctuate during the year, quality of construction (workmanship & materials), the water usage of the family being served by the system and maintenance. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory for current or future occupants or guarantee that no unseen encroachments, deficiencies or discrepancies exist can be given by First Water Consulting & 11/19/24 MUNICIPALITY OF ANCHORAGE or Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Owner Lift Station/Pump Vault Maintenance Log Street Address 1,$_'/ 3 Septic Tank: -Sludge level inches -Pumping: required e no -Pumping completed es no Lift station: SCP P21 -Pump basket cleanedresno -Effluent filter cleaned es no -Control floats cleaned -Proper float settings confirmed e no -Operation satisfactory Alarm System: •Dedicated electrical alarm circuit es no -Audible and visual alarm inside dwelling -Alarm system operation Qatisfacto not satisfactory Manhole Riser -Ground water intrusion at riser to tank connection es no -Ground water intrusion around pipe penetrations es o -Manhole lid: Functional es no Insulated es no Other -Weep hole functional es no Properly Secured s no -All manufacturer required inspections and maintenance completed es no Comments: Qualified Maintenance Provider: Technician L ac (`)L_\A). BekJ Company &S Signature Date of maintenance A_*4 SSMH SPEED LIMIT SIGN POWER OUTLET "NO OUTLET" SIGN ROAD SIGN CL MON 40 . 5 ' 28.6'10 . 4 ' 3.7' 6.4' 3.7' 43 . 7 ' 4.3' 24.3' WOODEN FENCE GRAVEL PAD BRICK PAD SECOND STORY DECK CANT. ROCK RET. WALL ROCK RET. WALL WOODEN PAD WOODEN PAD GRAVEL PAD ELEC. SAFETY SWITCH OPEN AIR SHED GABION WALL GARDEN AREA SURROUNDED BY ROCK RET. WALL FENCED GARDENGRAVEL PAD LANDSCAPING SHED SHED DECK GRAVEL DRIVE BRICK PAD BRICK PAD ROCK RET. WALL CINDER BLOCK RET. WALL CINDER BLOCK RET. WALL CINDER BLOCK RET. WALL SEPTIC DIRT DRIVE GAS METER ELEC. METER WEST 1/2 BLM LOT 188 54,450 SQ. FT. 1.25 ACRES 3-STORY HOUSE 33 ' R O A D W A Y A N D P U B L I C UT I L I T I E S E S M T . P E R PA T E N T ROCK RET. WALL GABION WALL WOODEN RET. WALL ROCK RET. WALL GARDEN SURROUNDED BY ROCK RET. WALL EAST 1/2 BLM LOT 188 BLM LOT 187 50' ROAD R.O.W. PER PUBLIC LAND ORDER 601 BLM LOT 165 N90° 00' 00"W 164.92' N0 ° 0 8 ' 0 0 " W 33 0 . 0 0 ' 33' ROADWAY AND PUBLIC UTILITIES ESMT. PER PATENT RABBIT CREEK RD. CL LO C L O M A N L N . R. O . W . 65.1' 74 . 6 ' 67.8' 18 7 . 1 ' N90° 00' 00"E 164.92' S0 ° 0 8 ' 0 0 " E 33 0 . 0 0 ' 33 . 0 ' 50 . 0 ' 33.0' WELL IN WELLHOUSE SEPTIC 100.0' Alaska Construction Surveys 907 E Dowling Rd, Suite 10 Anchorage, Alaska 99518 Office: (907) 344-5505 Fax: (907) 344-4775 Email: mcrow@akconstsurveys.com Site: RESIDENTIAL Address: 15131 Loc Loman Ln., Anchorage AK Field Survey Date: August 15th, 2024 Crew: F.C. Drawn by: F.C. Checked by: M.C., A.V. Scale: 1" = 25' Sheet: 1 of 1 ASBUILT SURVEY WEST 1 2 BLM LOT 188 LOCATED IN SE1/4, SEC. 33, T12N, R3W SEWARD MERIDIAN, ALASKA PREPARED FOR: LLOYD CROW EXCLUSIONS IT IS THE RESPONSIBILITY OF THE OWNER OR BUILDER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENENTS,OR RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR ESTABLISHING BOUNDARY OR FENCE LINES. ASBUILT CERTIFICATION I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING PROPERTY: WEST 1 2 BLM LOT 188, AND THAT NO ENCROACHMENTS EXIST, EXCEPT AS NOTED. ALASKA C CONSTRUCTION A SURVEYS S 24 Sep 2024 Feet 0 25 50 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT o, On -Site Water and Wastewater Section www.muni.org/onsite Septic Tank Advisory Certificate of On -Site Systems Approval # OSC241479 Subdivision: T12N R3W Section 33 Block: , Lot: 188 W2 907-343-7904 Fax: 343-7997 The septic tank for this property is 26 years old. The average life of an asphalt coated steel septic tank is 20 years. Typical replacement costs are $15,000 or more, not including engineering, surveying, MOA permitting fees or site restoration. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 30 year old steel tank MAY look like. MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT Y 907-343-7904 On -Site Water and Wastewater Section Fax: 343-7997 www.muni.org/onsite Nitrate Advisory Certificate of On -Site Systems Approval # OSC241479 Subdivision: T12N R3W Section 33, Block: , Lot: 188 W2 A water sample revealed a nitrate concentration of 5.30 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519-6650 * www.muni.org 7 Nitrate Fact Sheet From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.