HomeMy WebLinkAboutPROSPECT HEIGHTS #5 BLK 1 LT 4Prospect Heights #5 Lot 4 Block 1 #015-135-04 '" Municipality of Anchorage Page I of DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: -~.t~c~ O~-O~ PID Number: Ot~ --|'~5 'Out Name: CO~'~h~ I~ '~1~0~,}' Wastewater System: ~New D Upgrade Address: ~ ~0 I ~o ~e~ 7~ ~zoo n~,.~. ABSORPTION FIELD Phone: ~ -- ~ J No. ofB~rooms: ~ DeepTrench ~ShallowTrench ~ Bed ~ Mound ~ Other LEGAL DESCRIPTION So,.~,n,: ~.~ GPD/Sq. Ft. Total Depth fro~o~iginal grade: Subdiv~ion: ~ ~ Depth to pipe bDt/em Irom original grade: Gravel depth beneath pipe Township:I Ran~e=I ,o,,on: Fill added above original grade: ~el~gt;~t~ ~01 Ft. WELL: ~ New ~ Upgrade Gravelwidth: ~t Number of lines: Distance between fines: Ft. ~ I O Ft. Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: Pipe material: Driller: Date Drilled: ~tat~cWater Level: Installer; Date installed: Yield: j ~ GPMII Pump~Set at: Ft. Casing Height~Above Ground:Ft. TAN K SEPARATION DISTANCES ~septic ~ Holding ~ S.T.E.P. To Septic Absorption Lift Holding ~ubilc/Pdvate Manufacturer: Capacity in gallons: From Tank Field Station Tank Sewer Lines ~E~ ~O O J Number of Compartments: Sudace w~t~ ioo~+ idol+ ~ ~ ~ LIFT STATION Lot Size in ga'o"s: I Manufacturer: Foundation ~ I ~0t ~ ~ ~ ~ "Pump on" level at: ~at: High water alarm at: Curtain Drain Remarks: BENCH MARK Location and Description: I Assumed Elevation: ~ I '~ ~ EagleEIver, Ala~kag~57? 2nd ~-Zz-~l ~,~ ,o.,~ c. cOWAN Department of Health and Human Se~ices approval ~,~t-: .............. ~:~ Reviewed and approved bz:/~ Date: 72-913 (Rev. 9/91) MOA 25 ~ 1~0, SW960307 :P*G~ 2 OF 3 . iVlun~i_cip. 9_[it.y_o.F Anchorac~e DEPARTMEN/ UI- HI:::AL/H AND HUI~AN SERVICES ENVIRONIVlENTAL SERVICES DIVISION P.g. Box 196650 ~,Anchor-age, Alaska 99519-6650eTe[ephone'. 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LOT 4, BLOCK 1, PROSPECT HEIGHTS NO. 5 P.I~.NO. 015-135-04 A B '-CO 45.5' 3.5' F7 F'/ CO 49,0' 5.5' I I i i i / ST1 49.5' 8.0' i i / I ST2 49.5' 17.5' '' ~/ / DBL1 51.0' 24.0' I I ' I ~' ,/ ! )BL2 56.5' 33.0' I I' / FD 59.0' 39.0' / / NEW TRENCHES C01 50.0' 35.0' I / co4 MT1 70.0' 67.5' ALT. SITE ~,21JI '77/ C03 67.0' 43.0' //,, ~,,,,,,// co,~ 90.0' 82.5' MT2 85.0' 75.5' /1i I iNSTALLED// OBL2' CO~ ~LO~V mvm~ (~) NEW 2000 GAL~ sn I r NEW 6 B D R M I DRIVEWAY HOUSE~ ~ .~,.. "SC~E t" = 40' ~ ~~ ~r...'"' '"'x"'.~A. ~ NO~ SW960307 ~a,G~ ,3 0~' Hunicipo, ti-'c o£ AnchoPo. Qe DEPARTMENT OF HEAETHAND HUI"1AN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 OAnchor'(:zge, A[o. sk0. 99519-66500~retephone, 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LOT 4, BLOCK 1, PROSPECT HEIGHTS NO. 5 P.I.D. NO. 015-1,55-04 ST1 ST2 -FINAL 5~-~ NEW Ix. , 90. 20~?T GAL. I 90.3 GRADE CO1 C01 = 94.5' C03 CO3 = 89.3' · MTI 002/C02 = 90.6' MT2 C04/C04 = 88.0' MT1 = 90.6~..~// MT2 = 88.7L--~.~~ MTI = 81.2'~ MT2 = 80.1'~ · NO WATER FOUND 70.6' B.O.H. N.T.S. From : ALPINE DRILL 987:345 0202 Nov, 20. 1997 10:40 PM P01 STATE.OF-AU~,SKA :' · .. DEPARTMI}NT OF N~O~L-R~URCE~' . ~ * ' D~V~SION. QF MINING.~,WA~ MG~T ' ~:. .. [~ATtON .OF WE~E ' WATER~WE~k RECORD .8~REHOLE DAT'A: Depth Color *' ~dm TO WI;L[ DEPTH: ' * DATE OF COMI?LE~rlON Depth of hole:~ft . · DEPTH TO STATIC WATE~"L~EL . . ....'.. USE'pF WELL ~'qJom~sti~; · O";r¢il~atlon D 'mi)nl~o~ -CASING .STICK.U~ fL plato: Casfng typ~ perforated ~en hope Oupths of Openings: , :tO It ' . SCREEN TYPE: Slot/Mesh Size:.. GRAVEL PACK TYPE: Volume used: · GROUT TYPE: Depth: from~ DEVELOPMENT METHOD: Oepth to top: ft to LEVEL.AND YIELd: ft PUMP'INTAKE DEP'i~: * fl Hori~opuwer:' :. WELL DISINFECTED UPON COMPLETION? INFORMATION; .' Authorized Re~ptesentati~ ~: 0NR/01VISION OF MINING & WATE8 M~MY ' ' 3601C St, Suite B00 ," ' RECEIVED DEC 19 !997 Municipah[y ol Al~c;nora§8 Dept. Health & Human Services MUNICIPALITY OF ANCHORAGE D PARTM NT OF AND UMAN S VIC S a~CHO~AG~, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW960307 DESIGN ENGINEER:S & S ENGINEERING OWNER NAME:ONEY JOHN ANTHONY & RITA GAE OWNER ADDRESS:10241 NIGH RD ANCHORAGE, AK 99515 DATE ISSUED: 9/24/96 EXPIRATION DATE: 9/24/97 PARCEL ID:01513504 LEGAL DESCRIPTION: PROSPECT HEIGHTS #5 BLK 1 LT 4 LOT SIZE: 49624 (SQ. FT.) NUMBER OF BEDROOMS: 6 THIS PERMIT: 6 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (iSAAC80) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: /~/~/J~~ ISSUED BY :~~~~'~ DATE: DATE: ROBERT C. COWAN, RE. ROBERTA, SHAFER, RE. Date: ~/'¢i. / 9 7 CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 SEWER&WATER Iv~dN ID(TENSIONS SEWER&WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE pLANS ROADDESIGN SOIL TEST PERCOLATION TEST STRUCTURAL & MECHANICAL INSPECTtONS ONSITE WASTEWATER DISPOSAL SYSTEM DESIGN Municipality of Anchorage DEPARTMENT OF HEALTH ~qD HUMAN SERVICES 825 L Street P.O. Box 196650 Anchorage, Alaska 99519-6650 REFERENCE: Lo RECEIVED JUN 9 1997 Municipality of Anchorage Dept, Health & Human Services The septic in~pe, ctions for the referenced property, were q-/.~3./¢;? . P~ Lor to submitting performed on ~/-z, [ q 7 and ~ the On-site Wastewater Disposal System an¢' r. Well Inspeqtion Report we are waiting for the~6?~,__c ?~/~3d~-.~r *.-~'~ be completed. If we may be of further service please contact us. Sincerely, Robert C. Cowan, P.E. 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 ROBERT C. COWAN, RE. ROBERT A. SHAFER, RE. HEALTH AUTHORI'fY APPROVALS SEWER&WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST PERCOLATION TEST STRUCTURAL& MECHANICAL INSPECTIONS ONSITE WASTEWATER D~SPOSAL SYSTEM DESIGN September 12, 1996 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 4, Block 1, Prospect Heights S/D Addn. #5 Request you issue a permit to drill a well and install a septic system to serve the proposed six bedroom house on the referenced property. Test holes were excavated and percolation tests performed. The approximate location of the test holes are located on the attached site plan. At the time of excavation, no water was encountered in test holes and after seven day ground water monitoring, the monitoring tube in the test hole was found to be dry. This property has enough area for a future septic upgrade which can be seen on the attached site plan. We do not anticipate any adverse effects on neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. If you require additional information, please contact us. Sincerely, Robert C. Cowan, P.E. RCC/g : Enclosure CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 17034 NORTH EAGLE RIVER LOOP . SUITE 204 · EAGLE RIVER, ALASKA 99577 '" FI] ---t ('DOll 'XO~ldclV) .~fllGV~[ 'lrllEli ,OOI SITE PLAN -o mO '-qm n" Z DESIGN DRIVE ROBERT C, COWAN, RE. ROBERTA. SHAFER, RE. HEALTH AUTHORIIY APPROVALS SEWER&WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERING STUDIES AND REPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST P~RCOLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SITE WASTEWATER DISPOSAL SYSTEM DESIGN ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 REFERENCE: Lot 4, Block 1, Prospect Heights S/D Addn. %5 September 12, 1996 GENERAL: 1. e e De The scope of this project includes the installation of a 1750 gallon septic tank and five foot wide drainfield to serve the proposed six bedroom residence for the referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. On all leachfield mound systems, the property owner shall be responsible for ensuring a satisfactory vegetation growth over the mounded area. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: me A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. e The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. e Ail standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 Page Two Lot 4, Block 1, Prospect Heights S/D September 12, 1996 Addn. $5 e Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement. m Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe° A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 0 Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches° The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page Three Lot 4, Block 1, Prospect Heights S/D September 12, 1996 Addn. %5 MINIMUM MATERIAL SPECIFICATIONS: me Any septic tank proposed for installation must be constructed by a Municipally approved septic tank manufacturer. e The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pip~ Perforated .Solid Cast Iron ASTM D3034 (PVC) ASTM F810 (HDPE) ASTM D2662 (ABS) Yes Yes Yes Yes Yes No Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. Ail leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the %200 sieve. 7e When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever applies. Page Four Lot 4, Block 1, Prospect Heights S/D September 12, 1996 Addn. $5 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. e The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR/OWNER PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG m PERCOLATION TEST LEGAL DESCRIPTION: ~--OT /'/ 8£ ~' '1 DATE " Township, Range, Section: 8 9 10 11 12 13 14 15 16- 17- 18- 19- 20- COMMENTS 8,o. WAS GROUND WATER ~ O ENCOUNTERED? S L IF YES, AT WHAT ~ O DEPTH? p E SLOPE SITE PLAN Depth lo Water After. A. I/ Monitorin§? O.,~y Date. ~/l"//C~f~ Reading Date Gross Net Depth to Net Time Time Water Drop ql~/eG O : oo ,- G '/;,'' - O: o t t '~,~; 7 Y~ " I" o:.c ~ ~7~" I" o: e~ t 7" I" PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN '~ FT AND ~ FT 72-008 (Rev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: Township, Range, Section: 1 2 3 4- 5 6 7 8 9 10 11 12 13- 14- 15- 16- 17- 18- 19- 20- COMMENTS -T-£ $ rr SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Water Alter Monitoring? SITE PLAN 1 N Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE "~' 7 7 TEST RUN BETWEEN __ __ (minutes/inch) PERC HOLE DIAMETER __ FT AND ~> FT S & $ ENGINEERING , PERFORMED BY: ~.~ Eag;" ~iver L~p Road No. ~ ...... ; CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ~~~GUIDELINES iN EFFECT ON THIS DATE. DATE: Cl /17 / q C 72-008 (Rev. 4/85) COSA Checklist Legal Description: PROSPECT HEIGHTS #5 BLOCK 1, LOT 4 Parcel ID: 015-135-04 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA Well log is filed with Onsite (or attached) Date drilled 4/9/1997 Total depth 205 ft Cased to 120 ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) 18+ in. Date of flow test for COSA 8/27/2020 Static water level at beginning of test 96 ft. Well production at time of test 5+ gpm Water storage tank volume NA gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate 6.95 mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date of Sample 8/28/2020 Comments __________________________________________________________________________________ B. TANK DATA Age of tank(s) 23 years Tank type/material SEPTIC / STEEL Measured operating fluid level in septic tank 50” Standpipes/foundation cleanout per record drawing Date of pumping 8/27/2020 C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 4/22/1997 ALL standpipes present per record drawing Total measured depth from grade 8 / 10 ft (max) Measured depth to pipe invert from grade 4.9 / 6.18 ft (min) N/A – pressurized field Monitor tubes go to bottom of effective. If not, state depth into effective (0.1-.32’ deeper per inspection vs IR) Code-required soil cover over field System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Adequacy test date 8/27/2020 Results Pass For 6 bedrooms Fluid depth prior to test 0 / 0 in Water added 900 gal New depth 0 / 7 in Elapsed time 1210 min Final fluid depth 0 / 0in Absorption rate 900 gpd Any rejuvenation treatment (past 12 months) N If yes, enter date Comments/Deficiencies: NE field cleanout could not be located with digging & appears buried a few feet below grade. E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No *7 ft Property Line > 5’ Yes if No ft Absorption Field > 5’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10’ Yes if No ft Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft If absorption field is under driveway comment below Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No F. ENGINEER’S COMMENTS *PER MOA IR. G. ENGINEER’S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. 9/15/2020 MUNICIPALITY OF ANCHORAGE    DEVELOPMENT SERVICES DEPARTMENT    907‐343‐7904  On‐Site Water and Wastewater Section                                                                                           Fax: 343‐7997  www.muni.org/onsite         Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org      Nitrate Advisory   Certificate of On‐Site Systems Approval # OSC201482  Subdivision: Prospect Heights #5, Block: 1, Lot: 4  A water sample revealed a nitrate concentration of 6.95 milligrams per liter (mg/L).   The  Environmental  Protection  Agency  (EPA)  has  established  a  maximum  contaminant level (MCL) of 10.0 mg/L for public drinking water systems.  While  private wells are not subject to this regulation, EPA standards are based on existing  health information and can therefore be used to gauge the relative quality of water  from private wells.  Since nitrates are known to slowly increase, we recommend  you monitor the water quality.  Please see the attached “Nitrate Fact Sheet” for  important information regarding nitrate.  This advisory must be attached to all copies of the subject Certificate of On‐Site  Systems Approval.                                 Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org  Nitrate Fact Sheet  From Northern Testing Laboratories, Inc.  Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water.  Nitrate  is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells.  SOURCE:  Nitrate is a major component of fertilizer and wastewater.  Often the nitrate is in the form of  ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the  oxidized form known as nitrate.  Sources of nitrate from wastewater include urea, ammonia cleaners,  food solids, and bacterial cells.  It may also result from the breakdown of organic matter buried in the soil.  TOXICITY:  Nitrate is generally not toxic to adults or children over the age of two or three years, but is  associated with a potentially fatal infant disease called methemoglobinemia.  In the digestive system of  young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood  stream.  There it combines with the hemoglobin and interferes with the ability of the blood to carry  oxygen.  For this reason, methemoglobinemia is referred to as “blue baby” disease.  The EPA limits the  concentration of nitrate in public drinking water supplies to 10 mg/L.  The standard has been lowered  from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization.  TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home  water treatment systems such as softening or iron filtration does not readily remove nitrate.  The best  method for limiting nitrate in well water is source control.  This can include avoiding overdosing of  fertilizer near the well and maintaining good separation distances between septic tank leach fields and  the well.  A special anion exchange filter that contains a medi a with a strong affinity for negatively charged  ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate.  TESTING:  Nitrate analysis is usually done by one of the several  “wet  chemical”  methods  using  a  spectrophotometer to read the final color endpoint.  Specific ion electrodes also can be used to detect  the activity of nitrate in water.  This laboratory uses several different wet chemical methods approved  under the public water supply laboratory certification program.  They also have test kits available, which  the laboratory uses to perform an inexpensive “screening test”, and with which the homeowner can  monitor the change in nitrate levels from their well.  They recommend comparing the test kit results  against a certified analysis from the lab occasionally to verify the accuracy of the kit.  We recommend  using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.          MUNICIPALITY OF ANCHORAGE    DEVELOPMENT SERVICES DEPARTMENT    907‐343‐7904  On‐Site Water and Wastewater Section                                                                                           Fax: 343‐7997  www.muni.org/onsite         Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org      Septic Tank Advisory   Certificate of On‐Site Systems Approval # OSC201482  Subdivision:  Prospect Heights #5  Block:1, Lot: 4  The septic tank for this property is 23 years old.  The average life for a steel septic  tank is 20 years. Typical replacement costs range from $7,000 to $11,000.   This advisory must be attached to all copies of the subject Certificate of On‐Site  Systems Approval.               This is an example of what the metal of a 30 year old steel tank MAY look like.      Parcel I.D. Municipality of Anchorage Department of Health and Human Services Division of Environmental Services On-Site Services Section 825 "L" Street Room 502 P.O. Box 196650 Anchorage, AK 99519-6650 www. ci.anchorage.ak.us (907) 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 01 5 - 1 3 5 - 0 4 HAA# ,(J//t~"C'~,~ Expiration Date: GENERAL INFORMATION Complete legal description Lo t 4, B:lcok 1, Prospect Heights Location (site address or directions) 10200 Schuss Dr±ye Current Property owner(s) Harold Snow Mailing address Day phone 10200 Schuss Drive, Anchorage, AK 99516 346-1705 Lending agency Mailing address Day phone Real EstateAgent Dynamic/Karen Foster Day phone 261-7670 Mailing Address 3111 C Street, Suite i00F Anchorage, AK 99503 Unless otherwise requested, HAA will be held by DHHS for pickup. HAA picked up by: ~/~/2 ~,~.-~ NUMBER OF BEDROOMS: 6 TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Public Water System Well TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] [] Individual Holding Tank [] [] Community On-site [] [] Public Sewer [] The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) on properties served by a single family on-site wastewater disposal and/or water supply system. DHHS also issues HAAs upon request to home owners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation based on procedures outlined in the Health Authority Approval Guidelines for the Health Authority Approval application show that the on-site water supply and /or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type ot structure indicated herein. I further verity that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. S & S ENGINEERING 17034 Eagle River Loop Road No, ~:~gle River, Alaska 99577 Name of Firm Address Phone ~ ¢1 ':7' - ')- ~? 7 ¢/ Engineer's Printed Name Robert C. Cowan DHHS SIGNATURE 1,~ Approved for ~ bedrooms. Disapproved, Conditional approval for Date /]/¢ bedrooms, with the following stipulations. Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Expiration Date: Original Certificate Date: Reissue Date: 72 025 iRev 01 Municipality of Anchorage _ j~ Department of Health and Human Servic~l~ E C E ! V E Division of Environmental Services On-Site Services Section 825 "L" Street Room 502 P.O. Box 196650 Anchorage, AK 99519-6650 NOV 0 7 ~2000 www. ci.anchorage.ak.us (907) 343-4744 MUNICIPALITY OF ANCHORAGE ENVIRONMENTAL SERVICES DIVISION HEALTH AUTHORITY APPROVAL CHECKLIST LegalDescription: La~- ~ ¢Lo~.~ '1 P,~orP~.cT- N¢.,¢..-~4~'~' 4~' A. WELL DATA Well type ~ Date completed ~/'~/~/7 Total depth ~' o .5 ft Date of test Static water level Well production Cased to FROM WELL LOG WATER SAMPLE RESULTS: Coliform O colonies/100 mi Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material J~.~ r, c / Date installed If A, B, or C provide PWSID # __ Sanitary seal ¥~/- '¢ logo ft ft g.p.m Parcel I.D.: Well Log. ~//Z _r Wires properly protected .V~ .r Casing height (above ground) '~" in. AT INSPECTION Io/3o/oo ¢" ,~-. 5 -)- g.p.m Nitrate 3.~7 mg/I Other bacteria O colonies/100 mi Collected by: $ & S ENGINEERING '17034 Ea~ie [~ver Loop Road No. 204 Eagle River~ Alaska 99577 gal Number of Compartments High water alarm System type __ Depression over field ~v o For ~ bedrooms Tank size Cleanouts ¥~' Foundation cleanout ¥~.3 Depression over tank Date of pumping I~ / 7/~o Pumper C. ABSORPTION FIELD DATA Date installed L~/,).~/ ~? Soil rating~r ft2/bdrm) Length c40 ff r~,~ Width ~ ft Gravel below pipe Total depthS- I-~ fl Effective absorption area~'~(, ~' ft~ Monitoring tube Date of adequacy test/~/¢~/~, Results ~Fail) ?,~ Fluid depth in absorption field before test ~&Y in Wateradded ~1 '~ gal. Newdepth_ ~'~/;z in. Elapsed Time: ~-O min Final fluid depth ~- in Absorption rate >= ~ o o g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) ~ ~,"~ ~ ,,, o ,, ,~ .If yes, give date -- 72-026 (Rev. 01/00)* D. LIFT STATION Date installed Size in gallons __ "Pump on" level at ~ Datum ~ Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot ) O o ' +- Absorption field on lot Public sewer main ~v Sewer/septic service line High water alarm level at __ in Meets alarm & circuit requirements On adjacent lots On adjacent lots /06 -P t Ioo'+ Public sewer manhole/cleanout Holding tank N ,/4 SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Building foundation -/ ' Property line /o Water main N//J Water service line Drainage ,',,'/4 Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ~'/0 -+ Building foundation 3 5' 4- Water Service line !o !+ Surface water / o o '4- Curtaindrain~',~,,~. ~:~o,~,,, Wells on adjacent lots /oo Absorption field / o +- Surface water ) o o -~ Water main F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Date h/~, Driveway, parking/vehicle storage HAA Fee $ Date of Payment Receipt N.mber Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 01/00)* 11-02-00 lf:29 FROM-CTE ENVI RON~ENTA1 ,a~ CTIE EnvironmentaIServlceslnc. 5S15301 T-233 P.02/03 F-471 CT&E Ref.# 100676200l Client Name S & B Engineering Project Name/g L4 B l Prospect Hts #5 Client Sample ID ~ ~ l Prospect Hts ~5 Matrix D~ng Water Ordered By PWSID 0 Sample Remarks: Client POg Printed Date/Time 11/02/2000 15:36 Collected Date4Time 10/30/2000 10:45 Received Date/Time 10/30/2000 12:35 Technical Director Stephen C. Ede Allowable Prep Analysis Paramete* Re~tdts PQL Units Method Liners Date Date Init Waters Deparhment 3.1t7 0.500 mg/L EPA 300.0 10 max 10/30/00 SCL Microbiolo~y Laboratory Total Coliform col/100mL SM18 9222B 10/30/00 KAl) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343:4.744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING ParcelI.D.# 015-135 -oq 1. ~GENERAL INFORMATION Complete legal description Lot 4; Block 1; Prospect Heights #5 Location (site address or directions) NHN Schuss Drive Anchorage, AK · Prope~y oWner Connie Snow , Mailing address 550 West 7th , ..Lending agency " Mailing address 41200 Anchorage, Day phone 345-8359 A~ 99501 Day phone .Agent Address Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well NOTE: XXX Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site NOTE: Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. 5'Z $ EN61NEERiN6 Phone. (~ ¢/' ¢ -~-~ '7 ¢ Name of Firm ~7e~,4 Eagle ~,iver Loop Rea8 No. ;zu4 ~, ate River, Alaska 99577 Address /,..~_._ Engineer's signature . _ Date ? ,z./! S'/¢/~ D~/~ SIGNATURE Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments By: The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025(Rev. 1/91) Back MOAI¢21 :,.ONMENTAL SERVICES DIVIS',,. Municipality of Anchorage 0[(~ i (~ [99'i~ DEPARTMENT.OF HEALTH & HUMAN SERVICES Environmental Services Division [~ E C E J V J~ 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Legal Description: L.o-r A. WELL DATA Well type Log present (~/N) ~/E-~ Total depth ,,~,o Sanitary seal Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform O Health Authority Approval Checklist FROM WELL LOG If A, B, or C, attach ADEC letter. ADEC water system number ~ //~ Date completed ur / % /97 Cased to ) :~o Casing height (above ground) ~ Wires properly protected ~N) ~ ~- -J AT INSPECTION / o-~ ///-/ g.p.m, g.p.m. Nitrate ~. ~ ~ Other bacteria Collected by: S & $ ENGINEERING Eagle River, AlasEa ~9577 Number of Compartments Date of sample: , ~L [1~'/~ B. SEPTIC/HOLDING TANK DATA Date installed ~q~/ Tanksize Depression (Y/~) ~ o Pumper rating Or fF/bdrm) Soil High water alarm (Y,~ I. ~. System type Gravel thickness below pipe Total depth 8 Monitoring Tube present (~}'N) h/E-~ Depression over field (Y/~) Results (Pass/Fail) ~ For Immediately after -- gal. water added (in.): ~ Absorption rate = .g.p.d. If yes, give date bedrooms Foundation cleanout (~N) ~s Date of Pumping /~%.W.~ C, ABSORPTION FIELD DATA Date installed ur - 'z'~- ~i -/ Length('~ (~ 5~St') qo1%i%~h Effective absorption area -77 ~, Date of adequacy test /~ F_ ~ Fluid depth in absorption field before test (in.); Fluid depth (ins) Minutes later: Peroxide treatment (past 12 months) (Y/N) 72-026 (Rev. 3/96)* D. LIFT STATION Date installed _ Manhole/Access (Y/N) High water alarm level at? Septic/holding tank on lot Absorption field on lot Public sewer main Size in gallons _ ff" level at* _ On adjacent lots _ IOo~-~ On adjacent lots _ Public sewer manhole/cleanout _ ~oo~-t. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Sewer/septic service line ~- -~ t ~ Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation Property line _ 1o5 ~ Absorption field Water main/service line _ I o14' Surface water/drainage _I°o~'f Wells on adjacent lots. SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line ~o ' ~ Building foundat on ~o Surface water 18 Curtain drain Water main/service line Driveway, parking/vehicle storage area Wells on adjacent lots ENGINEER'S CERTIFICATION certify that I have determined thru field inspections and revi~ Inconformance/.~wi~7~ .l~g~linesineffect°nthisdate' Engineer's Name Date are: Date of Payment Receipt Number 7P-026 (Rev. 3/96)* Waiver Fee $ _ Date of Payment _ Receipt Number ~/~tk CT&E Environmental Services Inc. · 'J~J~,~'J~'~'all~J~J~l~'J~'~'. CT&E ReL# Client Name Project Name/# Client Sample ID Matrix Ordered By PWSID 977528002 S & $ l~ngineering N/A Lot 4 Blk 1 Prospect Hts #5 Drinking Water Sample Remarks: Client POg Printed Date/Time 12/19/97 09:40 Collected Date/Time 12/15/97 13:45 Received Date/Time 12/15/97 14:15 Technical Director: Stephen C. Ede Released By~ ~ ~.~//~ Parameter ResuLts PQL Units ALLowabLe Prep AnaLysis Hethod Limfts Date Oate Init ~trate-N Waters Department Analyses Total Co[fform 3.66 0.100 mg/L EPA 300.0 10 max 12/15/97 RNV 0.00 co[/lOOmL s~18 92228 12/15/97