Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SOUTH LAKEWOOD HILLS BLK 1 LT 8
5outh Lokewood Hills Lot 8 Block I #015-151 -09 �a 1 %(r-, r, Municipality of Anchorage Community Development Department had1 of 3 On -Site Water & Wastewater Program JAN I ! `- 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (9-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number. OSP181267 PID Number. 015-151-09 ❑ New ■ Upgrade Name: JOSEPH KOCIENDA ABSORPTION FIELD ❑ Deep Trench ■ Shallow Trench ❑ Bed ❑ Mound Address: 6520 O'MALLEY ROAD, ANCHORAGE, AK 99507 ❑ Other Phone: No. of Bedrooms: Soil Rating: Total Depth from original grade: 744-7377 5 0.8 GPD/Sq. FL 12.44 (MAX.) It. LEGAL DESCRIPTION Depth to pipe Invert from original grade: Gravel depth beneath pipe: SEE DWG. Ft 3.15 Ft Subdivision: Block: Lot: Fill added above original grade: Gravel length: SOUTH LAKEWOOD HILLS 1 8 SEE DWG. 111 Ft Ft Township: Range: Section: Gravel width: Beds Number of lines: Distance between lines: 5 Ft — FL SEPARATION DISTANCES Total absorption arca: 973+ umber of trenches: 1 Dist between trenches: r - To Septic Absorption Lift Holding PubliafPdvate From Tank Field Station Tank Sewer Lines SQ. Ft Ft Well 100'+ 100'+ - - 251+ TANK ■ Septic ❑ S.T.E.P. ❑Holding ❑ Other Manufacturer. Capacity. Surface Water 1004 100'+ - - N/A INFILTRATOR SYSTEMS 1530 Gal. Lot Line 10'+ .4'+ - - Material: Number of compartments: HDPE PLASTIC 2 LIFT STATION Foundation 10'+ 10'+ - - Curtain Drain NONE KNOWN Manufacturer. C Gal. Remarks: '2' LOT LINE WAIVER GRANTED (SEE WAIVER# OSV181060) 'Pump on' level at Pump ofP level at High water alar at Pump Make &Mode • Electrical Inspections performed by. PIPE MATERIAL House to tank F628 Tank to D3034 drainfield Installer POMRANING EXCAVATION, LLC. Drainfield D3034 CO/MT D3034 Inspector GEG, Ltd. BENCH MARK (Assumed elevation) 9736 Ft Inspection Location and Description: Dates: 1st 9/29/2018 2nd 10/2/2018 3rd 10/2/2018 4th - TOP OF BOTTOM STAIR TREAD FOR DECK ENGINEER'S SEAL Community Development Department Approval �s♦ �.••"�°° OF Conditional approval: Date: •°�� �� 9 ......... ..... ............ ........le.. .. r....�. .01 I ♦ : / .A .carne s : � - a �Z / C -7 _: ,•� A roved: Date: pp ♦ ROF ♦0;,;,��� LICENSE #AECC884 Inspection Report _1-1-12 PERMIT NUMBER: OSP181267 A I B I C DBL1 49.1 24.6 32.9 DBL2 50.4 26.2 34.5 C01 65.5 41.2 43.4 MH1 69.7 45.5 47.0 MH2 78.7 54.7 55.0 DBL3 82.2 58.3 58.2 DBL4 83.3 59.3 59.1 FD 1 94.2 1 71.9 74.8 CO2 83.1 66.1 79.2 MT1 84.1 67.5 80.9 CO3 191.0 169.5 169.4 MT2 190.5 168.8 168.4 C04 98.1 75.6 77.6 MT3 102.4 79.9 81.6 C05•• 171.7 148.9 146.5 MT4 1176.3 153.5 150.9 'SEE SWING -TIE NOTES RECORD DRAWING __� •`.� � .',-.>�:.::? .` ;.. EXISTING WELL I F >: 7. •.. / J / / N \ 4 / LU APPROXIMATE LOCATION OF NEIGHBOR'S SHED 'SWING -TIES NOTES: SWING -TES MEASUREMENTS SHOWN WERE GENERATED BY MEASURING FROM THE POINTS ON THE HOUSE TO EACH SEPTIC STANDPIPE FROM AN AS -BUILT SURVEY PERFORMED BY JEFFREY GASTALDI, RPLS DATED 11/6/2018. "C05 WAS NOT SHOWN ON MR. GASTALDI'S SURVEY AND IS SHOWN AS APPROXIMATE. STANDPIPE WAS PRESENT DURING INSTALLATION. 1► NEW 2 FOOT LOT LINE WAIVER GRANTED. INSTALLED 4'+ FROM LOT LINE BASED UPON SURVEY STAKES PERFORMED BY GASTALDI f*##,` / NOTE: THE THE 100 CREEK SETBACK, AND THE rd WEST AND SOUTH LOT LINES WERE FLAGGED BY JEFFREY GASTALDI, RPLS PRIOR/DURING • CONSTRUCTION. ALL SEPARATION DISTANCE `. WERE MET PER THE APPROVED SEPTIC DESIGN. 05' 000 Vi \A00 S� PARCEL ID NUMBER: 015-151-09 �- BENCHMARK = 97.36 - TOP \ OF BOTTOM STAIR TREAD NEW 1,530 GALLON 2 -COMPARTMENT INFILTRATOR PLASTIC SEPTIC TANK WITH 24 INCH DIAMETER INSULATED MANHOLE RISER ON INLET AND OUTLET ENDS OF TANK. \"-INSTALLED FLOW DIRECTOR (FD) 1 '--EXISTING DRAINFIELD TO BE USED AS A RESERVE SITE TH(F1 �• NOTE: ADDITIONAL ? GRADING OF THE I BACKYARD TO BE O5 COMPLETED IN THE T4 SPRING/SUMMER OF i 13'+ 2019 PER THE OWNER NOTE: THE OLD SEPTIC TANK x WAS DECOMMISSIONED PER l UPC PER THE CONTRACTOR. APPROXIMATE 100 FOOT SETBACK TO CREEK. 120' TO CLOSEST PART OF NEW DRAINFIELD PER JEFFERY GASTALDI, RPLS. VERIFIED DURING CONSTRUCTION. -/ /r A. �7j \fit GARNESS ENGINEERING GROUP, Ltd -- 1 CIVIL & ENVIRONMENTAL ENGINEERS: - 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507' PHONE (907) 337-6179' FAX (907) 33&3246' WEBSITE: www.gamewengineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOE KOCIENDA 744-7377 2 OF 3 PROJECT/LEGAL DESCRIPTION: DRAWN BY: SOUTH LAKEWOOD HILL S/D; BLOCK 1, LOT 8 J.L.M. TYPE OF WORK: DATE: RECORD DRAWING OF SEPTIC SYSTEM UPGRADE 1/10/2020 X - [SEPTIC AREA OF a FA a... ..... . ............... ........ .. i :• ey A. Gar ess : .°� o •���J, CE -795 ,CCN D AV� LICENSE,I1,'"S`,,_� SO #AECC884 i A SCALE: _ - - - - - - - - - - - -i LITTLE CAMPBELL CREEK `APPROXIMATE LOCATION f*##,` / NOTE: THE THE 100 CREEK SETBACK, AND THE rd WEST AND SOUTH LOT LINES WERE FLAGGED BY JEFFREY GASTALDI, RPLS PRIOR/DURING • CONSTRUCTION. ALL SEPARATION DISTANCE `. WERE MET PER THE APPROVED SEPTIC DESIGN. 05' 000 Vi \A00 S� PARCEL ID NUMBER: 015-151-09 �- BENCHMARK = 97.36 - TOP \ OF BOTTOM STAIR TREAD NEW 1,530 GALLON 2 -COMPARTMENT INFILTRATOR PLASTIC SEPTIC TANK WITH 24 INCH DIAMETER INSULATED MANHOLE RISER ON INLET AND OUTLET ENDS OF TANK. \"-INSTALLED FLOW DIRECTOR (FD) 1 '--EXISTING DRAINFIELD TO BE USED AS A RESERVE SITE TH(F1 �• NOTE: ADDITIONAL ? GRADING OF THE I BACKYARD TO BE O5 COMPLETED IN THE T4 SPRING/SUMMER OF i 13'+ 2019 PER THE OWNER NOTE: THE OLD SEPTIC TANK x WAS DECOMMISSIONED PER l UPC PER THE CONTRACTOR. APPROXIMATE 100 FOOT SETBACK TO CREEK. 120' TO CLOSEST PART OF NEW DRAINFIELD PER JEFFERY GASTALDI, RPLS. VERIFIED DURING CONSTRUCTION. -/ /r A. �7j \fit GARNESS ENGINEERING GROUP, Ltd -- 1 CIVIL & ENVIRONMENTAL ENGINEERS: - 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507' PHONE (907) 337-6179' FAX (907) 33&3246' WEBSITE: www.gamewengineering.com PREPARED FOR: PHONE NUMBER: PAGE NUMBER: JOE KOCIENDA 744-7377 2 OF 3 PROJECT/LEGAL DESCRIPTION: DRAWN BY: SOUTH LAKEWOOD HILL S/D; BLOCK 1, LOT 8 J.L.M. TYPE OF WORK: DATE: RECORD DRAWING OF SEPTIC SYSTEM UPGRADE 1/10/2020 X - [SEPTIC AREA OF a FA a... ..... . ............... ........ .. i :• ey A. Gar ess : .°� o •���J, CE -795 ,CCN D AV� LICENSE,I1,'"S`,,_� SO #AECC884 i \\\■ 788003V# 3SN3011 .������SS3JO�yd Q,>d, A AV 196L O�' ! Piv��♦ JNOl133d0LL •�.'""" """"""' / 1 ' ""' �• % (860Z/8Z/6 NO Alia 310H 1831) �LL'LL = W 310H iS31 d0 WOl1O8 JO NOUVA313 1S31 JO = Z# 310H 1SJO INO H 08 JO NOUVA313 0 ....... . 0 1. 6 a MZM/6 NO ZO'09 = Z# 310H 1S31 NI 2i31VMMno2io JO NOUVA313 •�* ••' ••• •�AV 89'98 = Hld3a NOIIVAVOX3 WnWIXVW ♦�♦ '••.,, ,,.��i EL'99 = S3NI1 NOI1n8Ril8Ia J012i3ANl 111 \\\\\\� 3n1103dd3 d0 96'E —T"RON 1 Vs m ^ T- M d330 EO'L � m (/�D 4�1 m 0 0-0 a Hld3a'XVW �77'Z6 o *C m m M�� OIUSV:l U311Id-/ ;pJ 2c o /� y o �j) Z#Hl U, zoo 6976 = 3(3VHE) m m z o !� ZTC6 = 3at80 D < g l J L#Hl E00 Z W 0O LL'96 = 3(3"0 ' Z086 = 3a`d2iJ = V� £6'h6 = aN3 H12iON E6'86 = aN3 H1nOS @7 3abIJO lVNIJ Zon @7 3aV�10 TdNIJ U) mom O o� U) oro om 9S'L6 = (NOUVOO12i0J E JO Z 3Jdd 33S) >1030 2iOJ ab'32J1 m M -i W0 iJIViS W01108=10 d01 SI 103rmAd IAW NUVVVHON38 :310N O�< n °5 C7 A mo m r �z w� u cp 0 m OD �z K „D �Z 7 90 Sm (�"� NNVi1 :]Olt�llI�NI imm^ 1N31U�] &400-2 N011` E) 0£5L-INI y 67'68 =131-Lno @ 3dld .4 30 i2GANI 98'68 = 131NI @7 3dld .4 JO ib3ANI 13 -lino -- -- --- — - a 131N1 m r- .-X5,:,:4 ;.; :.; •f,- 07'06=1311no @7 ANVl d0 d01 S1X31 (INV 11VIN3 03HOVllV 97'06 =131Nl @7 NNVl d0 dol RR 33S '2i3NMO 2i3d ANVi d0 0 0 -u = _0 dOl U3AO NouvinSNI JO I.bZ m L w m 0, c m '111=1NO` S UO 'NOiiv-lnSNl Z O z V Z O OIUSV=l U3111J JO NOliVllVISN1 O { O m m m ON1013M (INV NNVl ONI013M ONV ANV1 3OV60HONV A8 031lddnS 30VbOHONV A9 031lddns W V3H1103dSNl lON ala all 'J3Jp .SN.7Z No Pm 00 1 ;mon p .11N0 VNS` 9V - U3AOO 'X` VY 1J 9 - Hld3a V m ZHw LHw 111JM0V9 a3SV31IONl U0=1 S1N3W3Uin03U V y Z-190 t'laa NOI1V11`d1SNl ONIGIAVE 32i i • #T# tI#YU xs+ .WP N '46"E 280.051Mi 280.00'{R} t Tc Y z V tat 11 tid «A g v a i B D y D 45. ' f ! i �yl 3 { 9 E e RIDGECREST DRIVE °Y.. w{{ r Jody Maus rorn: Joseph Kociendo @memm> Sent: Sunday, November 24,2O198:S7PK4 To: Jody Maus Subject: Septic Install - 6520 Ornalley Rd This email is to certify that the septic tank was installed per the Infilitrator memo and documented in the pics sent earlier. Please let moknow ifthere isany other questions orconcerns? Sincere Regards, Joe (9O7)744'7377 al AT&T 10:29 AM 0 4W +1 (907) 744-7377 BVI®n, Sep 23, 11:15 AM Hi Jody. There is 5ft of cover with 24" of foam. 19% Do you have any pictures of this? don't have that specifically. Just the pics sent showing the 2ft of foam and the liner. We will need an email statement from you or Reid stating that the work was performed per this Infiltrator memo. Memo? 1 -1 - -- Ii A - I---- I - I I- -- - - -L-I-- A 4pay0 Q , 1, .. •' -A 2 •� 4 't' a ice•,+ . . t .. OF G A/ � a 49 o" A e i f i i! i♦ i i i i a i i e►• AN REESE LEAUT ��,rF9� • Iib. CE RR a .-`���' ©pROFESS���' NOTES: 4" STAND PIPE OR RISER (PER DESIGN) GRADE TO DRAIN (FINISH GROUND) NATIVE BACKFILL 6' FT MAX, INSTALL FILTER j FABRIC .A '+; .. --•:. CTOP OF TANK) ~. .. ` 3" MINUS TYPE 2A -a Ij INSTALL ON NATIVE SOIL BASE PER IM- SERIES INSTALLATION INSTRUCTIONS IM -SERIES TANK (ALL MODELS) 1- GEOFOAM (OR EQUIVALENT) 2 FT MIN. 2- GEOFOAM TO EXTEND 1 FT BEYOND EDGE OF TANK ALL SIDES. 3- BACKFILL SIDES OF TANK WITH No 57 STONE OR EQUAL.(3" MINUS TYPE 2A OR ROAD BASE MATERIAL) 4- 6" MIN. FILL OVER THE TANK (FOR GEOFOAM BASE). 5- WATER TABLE SHALL NOT EXCEED THE OUTLET PIPE INVERT ELEVATION 6- FILTER FABRIC SHALL BE AS APPROVED CURRENTLY BY HEALTH DEPARTMENT. 7- COMPACT BACKFILL IN 1 FT LIFTS (MAX.) WITH HAND VIBRATORY EQUIPMENT OR EQUIVALENT, 8- THERE SHALL BE NO VEHICULAR TRAFFIC OR SIGNIFICANT LIVE LOADS (LAWN TRACTORS ACCEPTABLE). 9 - GEOFOAM SHALL HAVE CLEAN, NEAT CUTS AROUND THE RISER(S) OR STAND PIPE. 10- BACKFILL TO GRADE WITH SUITABLE FILL, SLIGHTLY MOUND FINAL GRADE TO SHED SURFACE DRAINAGE AWAY FROM THE TANK EXCAVATION AREA. 11- GEOFOAM SPECIFICATION TO MEET OR EXCEED ATTACHED SPECIFICATION (INSULFOANI40160) LEAVITT JOB #18015.002 lKLEAVI7T & ASSOCIATES ENGINEERS, INC. guwetivm BiHiICTURAL *am P}iONE {maK6E0>aiF46ii70 FAIf(21D�4aSaaW INFILTRATOR - INFILTRATOR WATER TECHNOLOGIES 4 8usineas Parc Rd, Old Saybrook, CT 06475 (800) 2214436 INFILTRATOR /M -TANKS INSTALLATION REQUIREMENTS FOR INCREASED BACKFILL DEPTH 6 FT MAX. COVER -ALASKA ONLY- Nar. to s,:xa,Ehadwar. look 1 0# 1 GRADE• DRAIN •' -A 2 •� 4 't' a ice•,+ . . t .. OF G A/ � a 49 o" A e i f i i! i♦ i i i i a i i e►• AN REESE LEAUT ��,rF9� • Iib. CE RR a .-`���' ©pROFESS���' NOTES: 4" STAND PIPE OR RISER (PER DESIGN) GRADE TO DRAIN (FINISH GROUND) NATIVE BACKFILL 6' FT MAX, INSTALL FILTER j FABRIC .A '+; .. --•:. CTOP OF TANK) ~. .. ` 3" MINUS TYPE 2A -a Ij INSTALL ON NATIVE SOIL BASE PER IM- SERIES INSTALLATION INSTRUCTIONS IM -SERIES TANK (ALL MODELS) 1- GEOFOAM (OR EQUIVALENT) 2 FT MIN. 2- GEOFOAM TO EXTEND 1 FT BEYOND EDGE OF TANK ALL SIDES. 3- BACKFILL SIDES OF TANK WITH No 57 STONE OR EQUAL.(3" MINUS TYPE 2A OR ROAD BASE MATERIAL) 4- 6" MIN. FILL OVER THE TANK (FOR GEOFOAM BASE). 5- WATER TABLE SHALL NOT EXCEED THE OUTLET PIPE INVERT ELEVATION 6- FILTER FABRIC SHALL BE AS APPROVED CURRENTLY BY HEALTH DEPARTMENT. 7- COMPACT BACKFILL IN 1 FT LIFTS (MAX.) WITH HAND VIBRATORY EQUIPMENT OR EQUIVALENT, 8- THERE SHALL BE NO VEHICULAR TRAFFIC OR SIGNIFICANT LIVE LOADS (LAWN TRACTORS ACCEPTABLE). 9 - GEOFOAM SHALL HAVE CLEAN, NEAT CUTS AROUND THE RISER(S) OR STAND PIPE. 10- BACKFILL TO GRADE WITH SUITABLE FILL, SLIGHTLY MOUND FINAL GRADE TO SHED SURFACE DRAINAGE AWAY FROM THE TANK EXCAVATION AREA. 11- GEOFOAM SPECIFICATION TO MEET OR EXCEED ATTACHED SPECIFICATION (INSULFOANI40160) LEAVITT JOB #18015.002 lKLEAVI7T & ASSOCIATES ENGINEERS, INC. guwetivm BiHiICTURAL *am P}iONE {maK6E0>aiF46ii70 FAIf(21D�4aSaaW INFILTRATOR - INFILTRATOR WATER TECHNOLOGIES 4 8usineas Parc Rd, Old Saybrook, CT 06475 (800) 2214436 INFILTRATOR /M -TANKS INSTALLATION REQUIREMENTS FOR INCREASED BACKFILL DEPTH 6 FT MAX. COVER -ALASKA ONLY- Nar. to s,:xa,Ehadwar. look 1 0# 1 AV? IL Ac- - 4te Ile. 14 Ar WWI. .11 mlf � MUNICIPALITY OF ANCHORAGE ,,;n„ • On-Site Water&Wastewater Program Sz . . tfrfs. !� , PO Box 196650 4700 Elmore Road l Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 "t' http://www.muni.org/onsiteArtf ; lidi Dt i,artni( nt On-Site Wastewater Disposal System Permit Permit Number: OSP181267 Effective Date: 8/17/2018 Work Type: Septic Upgrade Expiration Date: 8/17/2019 Tax Code Number: 01515109000 Site Legal Address: SOUTH LAKEWOOD HILLS BLK 1 LT 8 G:2638 Site Mailing Address: 6520 O'MALLEY RD, Anchorage Owner: KOCIENDA JOSEPH J Lot Size in Sq Ft: 32130 Design Engineer: GARNESS ENGINEERING GROUP LTD Total Bedrooms: 5 This permit is for the construction of: El Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: ( � Date: r i f Issued By: I l i I I Date: : in I Mu• nicipality of Anchorage , z ), , P.O. Box 196650 0 4700 Elmore Road Anchorage, Alaska 99519-6650 e (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Department On-Site Water and Wastewater Section **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV181060 COSA#: Permit#: OSP181267 PID#: 015-151-09 Legal Description: South Lakewood Hills Block 1 Lot 8 Engineer: Garness Engineering Group Applicant: Joe Kocienda Your request for a waiver of the required 10 feet horizontal separation from the absorption field to the property line has been approved. The approved separation distance is 2.0 feet. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: Date: $ ilq18 Approved by: V�/ ,(A e04 Name of Reviewer **** VARIANCE/WAIVER REVIEW **'k* MUNICIPALITY OF ANCHORA 61 �5 7 Community Development Department E.-,-;.---T--r...) i •o ' :�` 4 3-7` la Development - Development Services m F 0073 40879'= On-Site Water & Wastewater Program Mayor Dan Sullivan 1- 4 w t �~ - Sewer/Well Permit Application !1 01 6 9 L 9 /� For A 'ngle Family Dwelling Parcel I.D. 615-67-09 Prope own- . • • • ' Day phone 744-7377 Mailing address 6520 O'MALLEY ROAD,ANCHORAGE,AK 995Q7 Site address 6520 O'MALLEY ROAD,ANCHORAGE,AK 99507 Legal description (Sub'd, Block& Lot) SOUTH LAKEWOOD HILLS S/D; BLOCK 1, LOT 8 Legal description (Township, Section & Range) Lot Size Sq.Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DEWELLING: (Ej all that apply) Initial n Single Family(SF) Absorption Field ® (w/wo ADU) Septic Tank ® Upgrade Z Duplex (D) ❑ Renewal ❑ Holding Tank ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: LOT LINE WAIVER&DRAINFIELD TO TEST HOLE/S Distance: 2 FEET&0 FEET I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal codes. GARNESS ENGINEERING GROUP,Ltd. (Signature of property owner or authorized agent) Permit/Rush Fees: JB I`Y(l2 /!(' Waiver Fees: 415-- q Date of Payment: 51O (� Date of Payment: b1 17110 Receipt Number: /����(YX096 Receipt Number: qa Permit No. v ?IO2l//o7 a W iver No. 63 1// g1 D (Rev.01/11) ma GARNESS ENGINEERING GROUP, Ltd ENGINEERING SALES CONSULTING August 13, 2018 Municipality of Anchorage Development Services On-Site Water & Wastewater Program 4700 Elmore Roade Anchorage, Alaska 99507 Phone: (907) 343-7904 Reference: Septic System Upgrade for South Lakewood Hills S/D; Block 1, Lot 8 To whom it may concern: The 5 bedroom house on the referenced property is served by a private well and septic system. Per MOA records, the septic system serving the subject property was installed in 1986 and consists of a 1,500 gallon steel septic tank and a deep trench type drainfield. The drainfield was found to be almost surcharged on 6/15/2018 and the owner would like to upgrade the system. We are proposing that a new 2-compartment 1530 Infiltrator plastic septic tank and a 5-wide drainfield be installed. Two test holes have been excavated in the area for the proposed upgrade and the drainfield has been designed around the 30 foot radii of these test holes. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications. 3. SURFACE WATERS: Little Campbell Creek is located to the south of the proposed drainfield. The 100 feet setback from the creek is to be flagged by a registered land surveyor to ensure the required separation distance to the proposed septic system will be met. 4. TOPOGRAPHY: Attached is the MOA contour map of the area. We have also taken elevations in the area of the proposed upgrade. As you can see on the attached cross-section detail drawing, the drainfield is proposed to be installed not quite parallel to the slope contours. The maximum depth from the highest original grade (south end) will be 12.5 feet deep and the shallowest point will be 7.1 feet deep on the north end. The design proposes a 6 foot separation distance to the bottom of the test holes and to the groundwater level found in test hole #2 on 8/7/2018. Based upon this information, we do not see any adverse effects with slope topography with the proposed design. 5. LOT LINE WAIVER: We request a 2 foot line waiver from the west property line to the proposed drainfield be granted. The neighboring septic system is over 10 feet from this lot line. We do not anticipate any adverse effects with the grating of this waiver. To insure this 3701 East Tudor Road,Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com Page 2 of 2 separation distance has been met, we request that a special provision be added to the permit that requires an updated as-built survey be performed by a registered land surveyor after the new septic system is installed and a signed copy be submitted with the record drawings. 6. DRAINFIELD TO TEST HOLE WAIVER: We request a 0 foot waiver from the proposed drainfield to the test hole. Both test holes was backfilled with native material and materials were sorted during excavation to ensure soils were backfilled with same type of soils that were excavated. We are not aware of any adverse effects with excavating the proposed drainfield near or over the test holes. Please do not h-sitate to call us at 337-6179 if you require further information. Thank you for your assistance. -ince ely, --re / arness, -.E., M.S. Presi 3701 East Tudor Road,Suite 101 *Anchorage,Alaska 99507-1259 Phone: (907)337-6179*Fax: (907)338-3246*Website: www.garnessengineering.com / 1 1 \ \ \ \ ` \ \ � �I / / I \ '� \ \\ \ '\\\\ VALLI VUE . / / I \ . \ \ VALLI VUE ESTATES S/D; / / I \ \\___, VALLI VUE \ \ \ ESTATES S/D; \\ BLOCK 2,LOT 6 / / I \ ESTATES SID; \ ' \ BLOCK 1,LOT 27 // I I J BLOCK 2,LOT 2 \\ \ / I r- -7\ // I i I ; \ 2, \ %//i \ \ \ % // I I I -\ ` \\ /i i%. // I I I I r — — — — — — — \ 11 \ • v,-,-, -- / /.%% VALLI VUE / VALLI VUE � VALLI VUE I I \ \\-// % i // ESTATES S/D; I ESTATES SID; I ESTATES S/D; i I i VALLIESTATES S/D; \ 1 , VALLI VUE / BLOCK 2,LOT 5 / BLOCK 2,LOT 4 BLOCK 2,LOT 3 , 1 1 I I ESTATES SID; 1 / / I BLOCK 2,LOT 1 1 / / I 1 I 1 I BLOCK 1,LOT 26 // NO CONCERN I NO CONCERN I NO CONCERN I i i NO CONCERN 1 I I J 1 I %-- O'MALLEY ROAD / / � \ // / / EXISTING �� I / / \ 5 BEDROOM \ // / \\ \ // HOUSE i \\~ ��� / ---\ iZ 1 �\ I I / I T / i r \\ rail=/ 1\ tI I f— 1 / I -I I \\ I 1 0 / I I \ o I 1 \\ _ m PROPOSEDFkiiii, 11 \1 \ a SEPTIC / I / I I \ \\ $ UPGRADE / / z W I I \ \ X o / / / -a >I 1 \ \ O C / / 1.4 \ // Er 1 (� / ' I SOUTH LAKEWOOD iS+\ Q EXISTING \ Q /w HILL S/D; k ) cl`- O SEPTIC BLOCK 2,LOT 1 ‘ 0 44 TH#2 li TANK I SEPTIC AREA (� `'\ -9 "P LI ABANDONED ' W \v` SOUTH LAKEWOOD DRAINFIELD C7 I `� SOUTH LAKEWOOD HILL SID; IR 0 (APPROX. SOUTH LAKEWOOD 0 HILL S/D; LOCATION)• HILL S/D; BLOCK 1,LOT I BLOCK 1,LOT 6 I EXISTING BLOCK 1,LOT 9_—I_` TH#1 DRAINFIELD �I \ x•11 SOUTH LAKEWOOD SEPTIC AREA// I \\ -_-_----_�` HILL S/D#1; / \ N. BLOCK 1,LOT 10 SOUTH LAKEWOOD / \ I N HILL S/D#1; I 1 I 1 BLOCK 1,LOT 11 100.WELL RADIUS I I I ki ; I I I 1•'%• / N SOUTH LAKEWOOD \. . \• / ' 1 HILL S/D#1; I \. r ,L__ .- •_••=:.".'r__________— --- — -- -- --- / / \ BLOCK 3,LOT I �• —. -- ----- / SCALE: I \ Y I \ , \, 1 //1 r-loo 1 I • ,/ I s GARNESS ENGINEERING GROUP Ltd = *1 . 4': I* ' 0 ;I� 'e 0 CIVIL&ENVIRONMENTAL ENGINEERS[,•-`,:, :',---:=..---=-- --•=,,'!x-•-,---- � � 3701 E.TUDOR ROAD.SUITE 101'ANCHORAGE.AK 99507•PHONE(907)337-6179'FAX(907)338-3246'WEBSITE-www.gamessengineenng com6 PREPARED FOR: PHONE NUMBER: PAGE NUMBER: 0 r% - ess = JOE KOCIENDA 744-7377 1 OF 3 ���,'� ' C -7913 ••'' PROJECT/LEGAL DESCRIPTION: DRAWN BY: •. ...•ejif-2. va••� ,.. SOUTH LAKEWOOD HILLS S/D; BLOCK 1, LOT 8 J.L.M. �0�; p E SS; P�4• TYPE OF WORK: DATE: LICENSE 4k %„``*44 SITE PLAN FOR SEPTIC SYSTEM UPGRADE 8/7/2018 #AECC884 / ,•' V';• A:.'. R.O.W.EASEMENT �— ` 4 - - --I— -1 IG ..,-. :. / '�• � .•_• !.'�a-•.�' EXISTING WELL I I / •.. : / DESIGN CRITERIA: :"..- •::-' // NUMBER OF BEDROOMS: 5 I •:.� i• • . GALLONS PER DAY(GPD): 750 / • �:, '.��'+••a".`•••:'•. / PROPOSED APP.RATE: 0.8 GPD/SQ.FT.PERCOLATION RATE/S: 6.7&5.6 CH I / - .A' -//PP///, G• .,,:♦ :MINIMUM DRAINFIELD SOFT.: 938 ' DOUBLE / ' / NS��N M( CLEANOUTS 1 58°0 V� I DRAINFIELD DESIGN: / NQI MAXIMUM DEPTH: 12.5 FEET MAX.DEPTH / 'VIe WIDTH: FEET DETAIL,PAGE 3 OF 3) / \ 1 ,EFFECTIVE: 3 FEET REDCTION FACOR: 0.58 /ACTUAL SQFT.: 948 / B.M.=97.36 1\ Y.0 .Gs / INSTALL w PROPOSED 1,530 GALLON 2-COMPARTMENT OUBLE U INFILTRATOR PLASTIC SEPTIC TANK.AREA // — / CLDEANOUTS <0 o MAXIMUM BURIAL DEPTWILL NEED TO BE HS NOT EXCEEDED.DED SO THE 4 // \ — �"� \ BURIAL DEPTHS FOR PLASTIC TANK CANNOT INSTALL FLOW DIRECTOR BE ACHIEVED A STEEL TANK SHALL BE USED./ / --- APPROXIMATE LOCATION \ - OF NEIGHBOR'S SHED Q. _ n 5` EXISTING SEPTIC TANK TO BE N 1 1 • DECOMMISSIONED PER UPC \ I N cr V \ N`"to i! I C. /:-.. i L� -H#2 ABANDONED DRAINFIELD (APPROX.LOCATION) PROPOSED DRAINFIELD I (SEE DESIGN CRITERIA, AND DETAIL DRAWING ' �c•_ ON PAGE 3 OF 3)EXISTING j "�E )1 GREEHOUSE TO I 1 EXISTING DRAINFIELD TO BE S ALE: BE REMOVED OR USED AS A RESERVE SITE RELOCATED TH#1 1'=40' 1 GEG,Ltd.HAS AN 8 PAGE SPECIFICATION LETTER THAT PERTAINS TO THIS DESIGN. BY ,O PROCEEDING FORWARD WITH THIS T INSTALLATION,THE ENGINEER,WELL DRILLER, CONTRACTOR AND PROPERTY OWNER AGREE [_] THAT THEY HAVE READ THESE Co SPECIFICATIONS AND AGREE TO ACCEPT THE X —... { e--REQUESTING A 2 FOOT LOT LINE WAIVER TERMS AND CONDITIONS OUTLINED. '\ I _ T N LITTLE CAMPBELL CREEK II \' ---- / I APPROXIMATE LOCATION I SEPTIC AREA / APPROXIMATE 100 FOOT SETBACK TO CREEK(SEE NOTE) / • NOTE:THE CONTRACTOR MUST HAVE THE 100 FOOT WELL RADIUS,THE 100 CREEK SETBACK, x AND THE WEST AND SOUTH LOT LINES FLAGGED BY A BY A REGISTERED LAND SURVEYOR �• PRIOR TO ANY CONSTRUCTION AND A MANDATORY LAYOUT SITE VISIT WITH THE CONTRACTOR I `�, AND ENGINEER SHALL BE PERFORMED TO ENSURE ALL SEPARATION DISTANCE WILL BE MET. 1 r GARNESS ENGINEERING GROUP, Ltd�, 1 . CIVIL&ENVIRONMENTAL ENGINEERS J 0 3701 E.TUDOR ROAD,SUITE 101'ANCHORAGE,AK 99507'PHONE(907)337-6179'FAX(907)338-3248'WEBSITE:www.gamessengineering.com ,y • • • PREPARED FOR: PHONE NUMBER: PAGE NUMBER: Garn=,s r 4�i: JOE KOCIENDA 744-7377 2 OF 3 °�J, C •-7• PROJECT/LEGAL DESCRIPTION: DRAWN BY: I� ,•••.••Q�I 4 :q.••�,43 • N/ 411 SOUTH LAKEWOOD HILL S/D; BLOCK 1, LOT 8 J.L.M. ..FD,p�p�V,f� (`„0, .• TYPE OF WORK: DATE: REVISED LICENSE44i ESS` _i4. DESIGN OF SEPTIC SYSTEM UPGRADE 8/17/2018 #AECC884 ��Im��� r \ DESIGN CRITERIA: NUMBER OF BEDROOMS: 5 GALLONS PER DAY(GPD): 750 PERCOLATION RATE/S: 6.7&5.6 MIN./INCH PROPOSED APP.RATE: 0.8 GPD/SQ.FT. Q MINIMUM DRAINFIELD SQ.FT.: 938 0 Z N- DRAINFIELD DESIGN: w CO W� a CO MAXIMUM DEPTH: 12.5 FEET MAX.DEPTH &0 CO w WIDTH: 5 FEET (SEE DETAIL,PAGE 3 OF 3) LLY 2 m M m p z0 zJ C) LENGTH: 110 FEET W Z LL }2 fV EFFECTIVE: 3 FEET <0 W O REDUCTION FACTOR: 0.58 w o 0th < a CO ACTUAL SQ.FT.: 948 a a a o 0 NOTE: BENCHMARK FOR PROJECT IS TOP OF BOTTOM STAIR ^ a TREAD FOR DECK(SEE DESIGN FOR LOCATION) = 97.36ii a g t1 C wo ui J W MT CO LI v C W,, Z EXISTING AND PROPOSED FINAL GRADE GRADE=98.02 W'° Q GRADE=96.77 p T.#1 , 7 Z2 Q GRADE=93.52 'r / 11J$ LU GRADE=92.61 I 01 Ja CO CO MT T'#2 g in co O Z ` FILTER FABRIC Y.� I- f / 12.5 FEET MAX.DEPTH 2n n 7.1 FEET _ iiZr§ 16 .rx 4 ..(APPROX.) Ou 0 O 1 ; Ill : 3OFEFFETIVE .a 0 V w° CO < INVERT OF DISTRIBUTION LINES=88.52\\____ 1 Q MAXIMUM EXCAVATION DEPTH=85.52 ax ` Z, •JJ -- ^ELEVATION OF GROUNDWATER IN TEST HOLE#2=79.52 52o -~ Lu —ELEVATION OF BOTTOM OF TEST HOLE#2=78.02 —ELEVATION OF BOTTOM OF TEST HOLE#1=77.77 _ 0 o 0 J 0 z 110 FEET LONG • r) N > O MO zy U o w 81_ U) 4 w wD 0 2O oCC r W 0 v w SCALE: -' •�P.•••,...... •,95,4♦♦ • 1-971:i • ..• 41TH �� .. ..1111111111 0 ;.� • ! .. ♦♦ • % •••6414:111i7 E-795 .. 43 .. eil3/t.,....c •' LICENSE NI1O\[SS���4 \ #AECC884 C .**I►A►►►11 � 1/ • GARNESS ENGINEERING GROUP, Ltd , 9 '� • CIVIL&ENVIRONMENTAL ENGINEERS 0 • 0 3701 E.TUDOR ROAD.SUITE 101•ANCHORAGE.AK 99507•PHONE(907)337-6179'FM(907)338.3249'WEBSITE'.were gemessen9ineenlg con, '•' ' Mg • • I,• rz- A.Ga ness c Li ISOIL LOG - PERCOLATION TEST �•• ' :� C, . • 12' �Q LEGAL DESCRIPTION: SOUTH LAKEWOOD HILLS S/D;BLOCK 1,LOT 8 • /C(:, •... V I 2,)1�/.""c��� PERFORMED FOR: JOE KOCIENDA DATE: 7/6/2018 111 :ROFESS��N�.� LICENSE 1j1►►►"*** DEPTH 6" ORGANICS #AECC884 (feet) :== TEST HOLE #1 1 —;I ~ LOAM (SM) 2 SOIL CLASSIFICATIONS SITE PLAN • SM W/ SOME ° GW .= 3 ORG • • GRAVEL & • ..• . GP J ~ I ML • ANGULAR ROCK I GM �/ 1 CL • • & BOULDERS /4//'3 GC ' OL \P� 4 �• • GoC0°Oo°Vc SW i i MH Q •�'• SP / CH \�� 5 • • • • :• • } T��` SM ' ,��,; off �o • • y7, SC N s • I • 'e. • 7 ,•' _ ' DEPTH TO DATE '• • • GROUNDWATER .4 N 1 5 8 —i ' • DRY TO 12.5' 7/6/2018 • • • • • • SM DRY TO 12.5' 7/19/2018 SCALE: • ii 9 la • DRY TO 19' 8/2/2018 1"=100' • i • DRY TO 19' 8/7/2018 10 --'' . DATE READING CLOCK NET TIME WATER LEVEL NET DROP 11 J•I • TIME (MINUTES) READING (INCHES) 12 — : • 7/11/2018 1 11:18 - 6" - • • B.O.H.ON 7/6/2018 2 11:48 30 3/8" 5-5/8" • ' • 13 --'t3 11:48 6" - •• ' • 4 12:18 30 5/8" 5-3/8" •1' • • 14 — 5 12:18 - 6" - ' • • I• I • 6 12:48 30 5/8" 5-3/8" 15 —1. 7 12:48 - 6" ,• • • SM 8 1:18 30 5/8" 5-3/8" 16 J• I ( • 18 .••• • :so:••••. � • SP PERCOLATION RATE 5.6 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 l'.1****.' B.O.H.-DEEPENED ON 8/2/2018 TEST RUN BETWEEN 5.0 FT. AND 6.0 FT. 20 A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES • NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: ERIK WIDGER COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I,JEFFREY A.GARNESS,CERTIFY THAT THIS WAS P'RFO$M•1 D IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 6 12-- IDI r%%Amu%11 ii 4 44 GARNESS ENGINEERING GROUP, Ltd *•: 4.....H , • CIVIL&ENVIRONMENTAL ENGINEERS .4440 • 3701 E TUDOR ROAD.SUITE 101'ANCHORAGE.AK 99507•PHONE(907)337.6179'FAX(907)338.320 T WEBSITE'.www g 5engncennq tom /•• .•• • • ' • Ct, �• •• - -y A. arness'.c ISOIL LOG - PERCOLATION TEST • 0• % C -79 3 LEGAL DESCRIPTION: SOUTH LAKEWOOD HILLS S/D;BLOCK 1,LOT 8 4p •.•�9 y i g.. (vim: PERFORMED FOR: JOE KOCIENDA DATE: 7/6/2018 •*4�'°ROFES .1oNPi.4 LICENSE ,1I1Ii�"`�44 DEPTH - #AECC884 (feet) _ TEST HOLE #2 1 --CZ _ __ -: ORGANICS/PEAT MIXED W/ GRAVEL SOIL CLASSIFICATIONS SITE PLAN __ 2 —` (DISTURBED) 0:_,.o •., GW __ : ORG 3 GP 1 ML ORGANICS/ ' GM ��-� CL �9, JOL MH 5 • ' '::•.:; SP J CH •-v- Z, r i • SM ' ,� .i OH (9 • SC 1` s •• • PG 7 —,•• • • DEPTH TO DATE • GROUNDWATER �<(iP N • 5 8 _ADRY TO 12.5' 7/6/2018 •I 6S WITH DRY TO 12.5' 7/19/2018 SCALE: o g -�I • iZiiii 6 SOME GRAVEL 15' 8/2/2018 1'=100' '• • 14' 8/7/2018 10 —. 11 —;• • ' DATE READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) . • II • • 7/11/2018 1 11:15 - 6" - 12 J' •• • • B.0.11.ON 7/6/2018 2 11:45 30 1 -1/8" 4-7/8" 13J•• • 3 11:45 - 6" - •• • - * SM WITH 4 12:15 30 1 -1/2" 4-1/2" 01 14 • SOME GRAVEL 5 12:15 - 6" - • •• • 6 12:45 30 1 -1/2" 4-1/2" 15 •. • • 7 12:45 - 6" • SP B.O.11.-DEEPENED 8 1:15 30 1 -1/2" 4-1/2" 16 — ON 8/2/2018 17 — 18 — PERCOLATION RATE 6.7 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19 — TEST RUN BETWEEN 5.0 FT. AND 6.0 FT. 20 - - A FOUR HOUR PRESOAK WAS PERFORMED: ❑ YES El NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: ERIK WIDGER COMMENTS: PERCOLATION READINGS ARE WITHIN 1/16 OF INCH. PERFORMED BY GEG, Ltd. I,JEFFREY A. GARNESS,CERTIFY THAT THIS WAS PER ORI*D IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: G /2- / f J , MUNICIPALITY OF ANCHORAGE DE, ~TMENT OF HEALTH AND HUMAN SER~ ~S Environmental Health Division ', $25 "L' Street, Aechorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Address lownship, Range, Section TANKS SEPTIC [~ HOLDING TYPE OF SYSTEM TRENCH L~ BED L~ W. DRAIN L~ OTHER Nurnbof cfi ...... Soil rating Pipe cnaterlal F~,.~[~ FSI 8 DISTANCES ~ SEPTIC TANK WELL LOT LINE FOUNDATION ABSORPTION WELL FIELD FT WELLS L~ PRIVATE ~3 OTHER {Identilv) (ABC) 1oral DepLh [Cased to FTJ FT RE~ARKS: by: I _ cnrtJly thai IhJs inspection wa~ periormed according Io all 72-013 (3/85) 2 2 2. 5 - [- · JUN .. [971 E&.,.!3CI-( ~ :t ,/~ SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264*4720 PERCOLATION TEST SOILS LOG - PERCOLATION TEST LEGAL DESCRIPTION: SLOPE 7 9 DATE PERFORMED: 10 11 12 13 14 15 16 17 18 19 20 COMMENTS WAS GROUND WATER /~/ S ENCOUNTERED? // y ~ ~ P E IF YES, AT WHAT ¢ DEPTH7 Gross Net Depth to Net Reading Date Time Time Water Drop i 0 o o PERCOLATION RATE t.._~,'~ (minutes/inch) TEST RUN BETWEEN Z . F* AND t~ FT CERTIFIED BY: ~ DATE:¢~/~h 72-008 (6/79) PERFORMED FOR: LEGAL DESCRIPTION: 4 5- 6- 7- 8- 9- 10- 11 13- 14 15- 16- 17- 18- 19- 20- MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST ~ SOILS LOG [] PERCOLATION TEST SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT __ - DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATIONRATE(~' ~1,~) a (minutes/inch) TEST RUN BETWEEN FT AND -- FT COMMENTS PERFORMEDSY: ~ 3~//~,Ai~y CERTIFIED BY: DATE: 72-008 (6/79) Pr,-- · Ik]Sq~/~LL~ K/lOkll~OR Parcel I.D. 015-151-09 Certificate of On -Site Systems Approval Expiration Date: Legal description SOUTH LAKEWOOD HILLS BLK 1 LT 8 Site address 6520 OWALLEY RD Anchorage AK Current property owner(s) KOCIENDA 7/31 /2025 X The On -site system(s) is/are approved for 5 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 9/3/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4J:Vil=li;ii__3 COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 MUNICIPALITY OF ANCHORAGE RL6q Development Services Department -343-7904 Phone:907 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 015-151-09 Complete legal description South Lakewood Hills Block 1 Lot 8 Location (site address) 6520 O'malley Rd anchorage, AK Current property owner(s) Joseph & Leah Kocienda Day phone 2. ON -SITE SYSTEMS SIZED FOR 5 BEDROOMS 3. TYPE OF WATER SUPPLY: [Z Private Well F] Private Well serving 2 dwelling units El Private Well serving 3+ dwelling units 0 Community Well or Public R Water Storage 4. TYPE OF WASTEWATER DISPOSAL: V Private SepticE] Private Septic serving 2 dwelling units F-1 Holding Tank F-1 Community Septic or Public Sewer 5. SEPTIC TANK: F1 Steel Z Plastic n Concrete n Fiberglass Age 6 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: F-1 AWWTS F] Bed E] Deep Trench kZ Wide Trench El Seepage Pit Waiver request for: Expedited review requested: n Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ Date of Payment C 0 S A # S C 9 1; 26 Waiver Fee $ Date of Payment Waiver # COSA Application —June 2022 Legal Description COSA checklist South Lakewood Hills Block 1 Lot 8 Parcel ID: 015-151-09 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA P/1 Well log is filed with Onsite (or attached) Date drilled 4/25/67 Total depth 159 ft Cased to 40 ft W Sanitary seal is functioning correctly ✓❑ Wires are properly protected Casing height (above ground) 22 in. Date of flow test for COSA 8/23/24 Static water level at beginning of test ll ft. Comments B. TANK DATA Measured operating fluid level in septic tank 44" Date of pumping 7/31/24 ❑ Required maintenance completed, if AWWTS Comments D. ABSORPTION FIELD DATA Which system tested (date installed) 10/2/2018 R ALL standpipes present per record drawing Total measured depth from grade 12.4 ft (max) Measured depth to pipe invert from grade 3.3 ft (min) ❑ N/A — pressurized field. ❑ Per record drawings, field is insulated. 0 Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced 2000 Qallons 8/23/24 date Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies Well production at time of test 6.1 gpm Water storage tank volume None gallons Well disinfected for coliform test? ❑ Yes 0 Nc © Coliform bacteria is Negative Nitrate 1.91 mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L 0 Arsenic less than MRL (ND) Collected by Arcterra Consulting Date 8/16/24 EW-111:01il ❑ Require Itenance completed Age of lift station rs Lift station material Comments: Adequacy test date Results Q Pass Fluid depth prior to test _ Water added 750 gal New fluid depth 12 in Elapsed time 1200 min 8/24/24 8 in Final fluid depth 8 in Absorption rate 750+ gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 37.8 in Effective depth used 8 in Effective depth remaining 29.8 in COSA Checklist June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' Q Yes if No ft ✓Q Yes if No ft Neighboring Tank > 100' 0 Yes if No ft Private Sewer/Septic Line > 25' JQ Yes if No ft Absorption Field on Lot > 100' 0 Yes if No ft Holding Tank > 100' Q Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' Q Yes if No ft ❑✓ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' © Yes if No ft 0 Yes if No ft ❑ N/A — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' ✓❑ Yes if No ft Surface Water > 100' Q Yes if No ft Tank to Property Line > 5' Field to Property Line > 10' Water Main > 10' Water Service Line > 10' F. ENGINEER'S COMMENTS Yes if No ft ❑ Yes if No 4* ft Yes if No ft 2 Yes if No ft * Waiver OSV181060 approved 8/16/18 for minimum 2'. Wells on Adjacent Lots: Private Wells > 100' Community Wells > 200' Yes if No ft © Yes if No ft If tank or field is under driveway comment below G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on -site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Areterra Consulting Phone (907)-696-6111 Engineer's Printed Name Kenneth Duffus Date 5/ � Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, AreTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies exist COSA Checklist June 2022