Loading...
HomeMy WebLinkAboutSUSITNA VIEW ESTATES BLK 3 LT 11Onsite File #020-091-27 Note in file indicates 1979 field may be in groundwater. Prior to issuing a drainfield upgrade or COSA, a test hole shall be provided within 30 ft of the 1979 drainfield to confirm separation to seasonal high groundwater. N U UU. LLD 00 U U U L 1laN27MY Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191134 PID Number: 020-091-27 Dwelling: 0 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New Upgrade Name: David Irons & Ann Rappoport ABSORPTION FIELD ❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound Address 17053 Aries Ct, Anchorage, AK, 99516 ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 345-3822 4 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot Susitna View Estates 3 11 Fill added above original grade Ft. Gravel length Ft. Township Range Section Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft2 Ft. Well >100' N/A N/A N/A >25' TANK ❑Q Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 1250 Gal. Surface Water >100' N/A N/A N/A Material Number of compartments Lot Line >5' N/A N/A N/A Epoxy Coated Steel 2 NA Foundation >10, N/A N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Tank replacement only under this Pump on level at in. Pump off level at in. High water alarm at in. permit. Pump make and model Electrical Inspections performed by Installer PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Wilco Contracting Drainfield Existlnq CO/MT Inspector J. Williams BENCHMARK (Assumed elevation) 100 ft Inspection 15` 4/30/19 nd Location and description 2 3rd 4"' Bottom of siding. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp � Conditional Approval: Date w® .••'"'�� �"'•' �® : • 49th X.... }, ............. ... ..%..... e 'Z J'� li 0. �...mn......m...w...........�.. 0�n MICHAEL E. ANDERSON D Qj No. CE -4381 ? e���(�,p''•. 6/12/19 ..•'°�t���� ......• � Approved ��(1(i�Di�Z Date 3 j j a0 2U 1m FO • .... � ®®• T`m �ck_&1? �®e®®0®®S0®®s's 11 wNccuui i MUPUI i_y- i- i c.uuc SUSITNA VIEW ESTATES, BLOCK 3, LOT 11 PERMIT # OSP191134 PID # 020-091-27 i i I EXISTING WELL LOT 10 4-BDRM HOM ` A Fco t 2cot 1,250 -GAL svi • SEPTIC TANK EXISTING WELL Sv2 zcoz LOT 11 EXISTING ABSORPTION TRENCH. LOCATION PER MOA FILES UNSUBDMDED A B 2C01 67.4 66.0 SV1 70.7 69.6 SV2 77.1 76.5 2CO2 80.8 79.9 MICHAEL E. ANDERSON :a SAW 0 50 100 No. CE -4381 e �'. 6112119 +FEET 4f, 5 , �E51 ®�®�� 1"=50' LEGEND CO -CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEAN( FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE SUSITNA VIEW ESTATES B3 L11 PERMIT # OSP191134 ENGINEERING PID # 020-091-27 PROFILE AS -BUILT (NO SCALE) R=20.00' W ro 0 W LL - 13 i 13 30.0' L=16.49' R=180.00' S�N p0 5.5'x8.4' / BALCONY \ t 96.4' \ ' 1.0' CANT \ \ \ o Lot 11 Z 42,801 s.f. \ GRAVEL DRIVEWAY\ 12.2'x16.2' SHED 3� ENCROACHES 2.0' ONTO LOT 10 N,g3N WELL • o. w .1 zs o CHAIN—LINKI FENCE w. °'° °' ss Lot 10 2 STORY RESIDENCE Ec s p w/ BASEMENT m \ CENTERLINE OF GAS/ LINE EASEMENT 100' PROTECTIVE \ WELL RADIUS SEPTIC PIPES �tC W GAS LINE EASEMENT 25BUILDING SETBACK , Unsubdivided 10' UTILITY PLOT PLAN AS BUILT —2L SCALE 1" = 50' GRID SW 3336 Project No. 19-140/A2 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates, in C. , (907) 522-6476 Phone (907) 522-4625 Fax 0000Op�O oo OFA / 0�4 Professional Land Surveyors kenOlongsurvey.com y jonathanOlongsurvey.com o G R�' �5�0 I hereby certify that I have surveyed the following described properly: LOT 11, BLOCK 3, SUSITNA VIEW ESTATES (PLAT No. 70-287) p * : 49TH �* 0� �" "•"' .6 Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that � I{�/, no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said property except as Indicated hereon. p' ....KEN. . ETH .: x i Q' Q Dated this the ° Day of N� 2! '1 at Anchorage, Alaska •.LS -5202.•' yJp� Opp p . . . • . . . . o d QO"OPESSIONAI. o It Is the responsibility of the owner to determine the existence of any easements, �DOO000� covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963 Engineer: Legal Description Parcel ID: Permit: Report Type: IVIU UIPMILy vt 1A11U11U1d9U On -Site Water and Wastewater Program P.O. Box 196550 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite Review Comments FORGE ENGINEERING EPLANS SUSITNA VIEW ESTATES BLK 3 LT 11 02009127000 OSP191134 SepticTank As Built Review r1 n ,1 llepartin ent 1/28/2020 Completed By: T.Ecklund The application has been reviewed and the following comments have been generated. These are to be satisfactorily addressed prior to MOA approval: 1. Please address provisions to the permit, letters of non -objection, field encroaching on GW and required to confirm slope to drainfield 2. Please provide an as -built survey 1) See attached letter of non -objection from Enstar. Slope to drainfield confirmed (no standing water in double cleanout after tank, and positive flow can be seen down pipe.) Request to address field to GW separation at time of future COSA. 2) See attached survey. ENSTAR Natural Gas Company June 26, 2019 Ann Rappoport and David Irons Family Trust 17053 Aries Court Anchorage, AK 99516 Re: Letter of Non -Objection — Absorption Trench Encroachment Dear Mrs. Rappoport and Mr. Irons, ENSTAR Natural Goa Company A DIVISION OF SEMCO ENERGY 401 E. Intonational Airport Road P. O. Box 190288 Anchorage, Alaska 99519-0288 (907)277-5551 ENSTAR Natural Gas Company (ENSTAR) has no objection to the existing absorption trench, within the twenty foot (20 FT) wide natural gas easement within Lot 11, Block 3, Susitna View Estates, according to Plat No. 70-287, Records of the Anchorage Recording District, Third Judicial District, State of Alaska, subject to the following special conditions: Acceptance and use of this letter of non -objection by yourself, your heirs, your assigns, or your successors, will constitute agreement to the following typical stipulations: • There is an existing 12 inch natural gas transmission pipeline within this natural gas easement. o No reduction of grade or increase of grade in the easement will occur without the prior written approval from ENSTAR Engineering. o All impermeable structures or surfaces must maintain a 36 -inch clearance to ENSTAR facilities. o ENSTAR will not be responsible for any expenses related to underground, surface, asphalt, concrete, curb, absorption trench etc. repairs if ENSTAR is required to excavate to access our facilities. Said costs will be the responsibility of the owner of the subject property at time any special construction expense is incurred. o Upon transfer of the property to another owner, the new owner shall apply for anew Letter of Non -objection, subject to an inspection of the premises by ENSTAR. • Landowner/Contractor working near ENSTAR gas facilities shall contact the Alaska Digline, Inc., (907) 278-3121 or 811 for line locating two (2) business days prior to any related excavation. This service is free of charge. • ENSTAR will be held harmless, now and forever for any damages or injury to any person or property as a result of this encroachment. Any ENSTAR facility damaged or destroyed, as a result of this encroachment will be repaired at no cost to ENSTAR. • Any costs incurred by ENSTAR for special construction necessitated by this encroachment will be borne by the land owner. 0 All applicable safety code regulations will be observed and maintained. Letter of Non -Objection LII B3 Susitna View Estates 612612019 • This letter of non -objection will in no way preclude ENSTAR from full use and enjoyment of its rights within any portion of its right-of-way. • This letter of non -objection shall not be in effect until the signed acceptance is received by ENSTAR. Sincerely, Andrew Fraiser Right -of -Way & Permitting Supervisor ENSTAR Natural Gas Company Accepted by: Trustee for the Ann Rapf3oporfand David fro ily Trust (2=Pzx::r,, -, - l Signature CJ Date '� (�" I r 0-\ "') l�� MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP191134 Work Type: SepticTank Upgrade Tax Code Number: 02009127000 Site Legal Address: SUSITNA VIEW ESTATES BLK 3 LT 11 G:3336 Site Mailing Address: 17053 ARIES CT, Anchorage Owner: RAPPOPORT ANN & IRONS DAVID Design Engineer: FORGE ENGINEERING This permit is for the construction of: ❑ Disposal Field O Septic Tank ❑ Holding Tank ❑ Privy Effective Date Expiration Date: Lot Size in Sq Ft Total Bedrooms: lieiia!'fllttrnL 4/30/2019 4129/2020 42801 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: 1. A letter of non -objection shall be provided from the gas company for the existing field located within the gas' line easement prior to inspection report approval. 2. The septic system shall not be installed within the 25 ft wide building setback. 3. Confirm that the piping between the tank and drainfieid is adequately sloped down towards the drainfield. 4. MOA records indicate that the existing drainfieid maybe in roundwater: Priorto issuance of a. COSA, an engineer shall confirm that the field is not in groundwater. Received By. Issued By: j- I k�'L Date: Date: .3p t GI !ll ??v8py 27US8 MUHM PAUTY OF ANCHORAGE Z/!!'ROVAWNVS Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 020-091-27 Property owner(s) David Irons & Ann Rappoport Mailing address 17053 Aries Court Anchorage, AK 99516 Site address Same Day phone 345-3822 Legal description (Sub'd., Block & Lot) Susitna View Estates, Block 3, Lot 11 Legal description (Township, Range & Section) Lot Size 42,801 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field F-1 Initial❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade FZ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is, in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: �13tob Waiver Fees: N Date of Payment: a` -t Iq Date of Payment: Receipt Number: j, D /-75-&D -75- Imo' Receipt Number: Permit No. dOP1 `Z 1 �J�`� Waiver No. Permit App_.;- : . �. c PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) April 24, 2019 MOA Development Services Dept, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Susitna View Estates, Block 3, Lot 11 – 17053 Aeries Court Septic System Design Dear On-Site Services Engineer: The septic tank on the subject lot is leaking and must be replaced prior to the issuance of a COSA for the property. The attached site plan identifies the location of the home and the existing well and septic system. No conflicts exist between this proposed septic tank and any other well or septic system, whether on this lot or adjacent lots. The new septic tank will be placed a minimum of 5’ from all deck or stairway foundation supports and all lot lines. The existing septic tank will be decommissioned in accordance with Municipal Code. The existing well on the lot is shown. The placement of the new septic tank will not encroach into surrounding protective well radii. Please refer to the attached plan sheet for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, P.E. 4-24-19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191134, Rebecca Carroll, 04/30/19 x x x x xFCO 10050 0 FEET 1"=50' 4-BDRM HOME NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND SUSITNA VIEW ESTATES, BLOCK 3, LOT 11 4/30/19FEODOSIA DRIVE20' GAS LINE EASEMENT CENTERLINE OF GAS LINE EASEMENT ARIES COU R T 10' UTILITY EASEMENT EXISTING WELL DECOMMISSION EXISTING SEPTIC TANK PER MOA CODE NEW 1,250 GALLON SEPTIC TANK. SECURE TANK AS NECESSARY TO PREVENT FLOTATION. SEE DETAIL 2CO 2CO SV SV EXISTING ABSORPTION TRENCH. LOCATION PER MOA FILES 25' BUILDING SETBACK Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191134, Rebecca Carroll, 04/30/19 SEPTIC TANK BALLAST (NO SCALE) SUSITNA VIEW ESTATES, BLOCK 3, LOT 11 BOUYANCY CALCULATIONS: (NEGLECTING WEIGHT OF TANK) BOUYANCY FORCE ON EMPTY TANK: 1,250 GAL CAPACITY x 8.35 LB/GAL = 10,438 LBS WEIGHT OF CONCRETE BALLASTS: 8'x2.5'x2.5' x 150 LB/FT3 x 2 = 15,000 LBS WEIGHT OF SOIL ABOVE TANK: 4'x8'x5' x 145 LB/FT3 = 23,200 LBS SAFETY FACTOR: 3.6 EYE BOLTS EVERY 2' 1 2" CABLE W/ TURNBUCKLE TIGHTEN OVER TANK 8' L X 2.5' W x 2.5' D CONCRETE BALLAST 1,250 GALLON SEPTIC TANK 4.0 CONCEPTUAL ONLY. OTHER METHODS TO SECURE TANKS WILL BE PERMITTED AT THE DISCRETION OF THE ENGINEER. NOTE:Michael E. Anderson 4831-ER EGISTEREDPROFE S S I O N ALEN GINEER 4-30-19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191134, Rebecca Carroll, 04/30/19 View Lot 11 Block 3 #020-091-27 MUNICIPALITY OF ANCHORAGE MEMORANDUM ¢ -.z3-- o o /$ 015 (Rev 9~97)* Municipality of Anchorage Poge 1 of 2 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchoroge, Alaska 99519-6650 Telephone: 545-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permlt Number:, SW000067 PID Number: 020--091--27 DAVID IRONS & ANN RAPPOPORT WastewaterSystem: · New [] Upgrode Address: 17055 ARIES CT, ANCHORAGE, AK 99516 ABSORPTION FIELD NO. of Bedroome:zl' DDeep :~ OUler7~r=d~'' Ph°n":.907.(' ) 545-5822 Tr=nch n Shollow Trench r'lsed nUound $~;I Rc~Jng: , Tot~ De~th fr~m Gl §rode: LEGAL DESCRIPTION o../~.. Ft. 1I : sUS~TN~3(~_. ".~ .~ ~ TANK SEPARATION DISTANCES · ~p~. ~ .o~n. ~ ~.~.~... ~ s~u.. T..k ~..r u.= ANCHORAGE TANK 1250 Well 1 OD'+ 100'+ -- 25'+ STEEL Su,OCewoter 100'+ 100'+ -- - LI~ Uno 5'+ 10'+ -- -- -- 5'+ 10'+ _ _ _ ~p o." r~ ~: "~ I~ .=~ =~=~ ~ Foundotion Droin = NONE KNOWN I I ~.mo~..: - ~o C~UCE ~EEP ~U.~ ~. BENCH MARK - GROUNDWATER SEEPING IN ABOUT A FOOT ABO~ TOP SOUTH ~ST CORNER OF R~R DECK OF TANK. - APP~S TO BE R~ERSE C~OE FROM EXI~NG SERVICE 100.00 Ins~ions pe~ by: AWWC, INC. D~s: 1st 4/21/2000 , 2nd s/~/2ooo ~ ~ ......... 3~ ~.¢ ~ d ~I re A. ~rness~ ~a~m~n~ o~ 8~lth ~nd ~um~n 8~i~ a~ro~al u~,,, .. ............. ..}~ Renewed and appmv~ by: 0 ~/_ ~. ~, Date: ~-~2- o~ AS-BUILT DRAWING SWO00067 020-091-27 65.2,3 65.00 65.50 65.55 71,40 71.1.3 80.65 81,22 81.75 82.94 81.33 8,3.28 A B DBL1 65,23 65,00 DBL2 65,50 65.55 ST1 71,40 71.13 ST2 80.65 81.22 DBL3 81.75 82.94 DBL,4 81.33 83.28 J.W.M. ~{ AI,AS~ WATER & WASTEWATER ,~[~: ~,:.~,t~ ]3: ~~=~==*~=~ CONSUkTANTS, INC.~==~=~-'~=~ 1 .....~ ~,~.., DAVID IRONS a ANN RAPPOPORT (907) 345-3822 2 OF 2 ;_ '¢~'ei'r, t A~ess/ ~ ~ ,~c..,,o,: '0~..~ ~-~ ..-"/fl SUS~T.* w~w SUmWS~O.: ,OT ~..,OC, ~ %¢:,'., ........... -,;~k~" AS-BUILT OF TANK REP~CEMENT '~%~ MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Apr 17, 2000 Expiration Date: Apr 17, 2001 Permit Number: SW000067 Legal Description: SUSITNA VIEW ESTATES BLK 3 LT 11 Design Engineer: 0041 AKWater & Wastewater Consultant Owner Name: Ann Rappaport & David Irons Owner Address: 17053 Aries Court Total Bedrooms: 4 Anchorage, AK 99516-5316 ParcellD: 020-09%27 Site Address: 017053 ARIES CT Lot Size: 42801 SQ. FT. Permit Bedrooms: 4 This permit is for the construction of: [] Disposal [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343~4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: Issued By: Date: 4 - /7-00 ALASICA WATER & WASTEWATER RECEIVED April 1 l, 2000 APR 12 .000 MUNICIPALI¥¥ OF ANCHORAGE :'qVIRONMENTA~. SERVICF$ Municipality of Anchorage DepmCment of Health & Human Services Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Tank Replacement Design for Lot 11,'Block 3, Susitna View Subdivision To whom it may concern: The existing 4 bedroom house is served by a private well and septic system. The existing septic tank is collapsing and is in need of replacement. The new tank will be positioned 5 feet east of the existing tank. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact me at 337-6179, or 244-9612. Thank you for your assistanc~ Sincerely,///~/ / ., M.S. Pre~ddnt NOTE: Attached is a site plan drawing, a design drawing, and a 3 page construction specification letter which are all part of the design package for this tank replacement. 6901 Debarr Road, Suite 2B - Anchorage, AK 99504 - Ph: (907)337-6179 - Fax: (907)338-3246 LOT ,4, BLOCK 1 I LOT 2, BLOCK 3 I mT ,a mr~r:~¢ ~; SUSITNA VIEW EST. I SUSITNA VIEW EST. I S~J~S'iTN'.~ ~/l'~"Es~r WELL LOCATED ON ~ ~ LOT 9. BLOCK 3 ,.OT.~, BLOOK~ I ~OS~B.J.;~'~j. ~, / / B,.,S,T,,,A VIEW ES~-. ~ SEPTIC / / / ~-- c;.. ,/ '--..."' '"'" ~". '-~-/....~./" ~d. ".. ~ LOT 2, BLOCK 1 ! .-k~ '~ \X~, ~ \ J ~ I LOMA ESTATES LOT 1. BLOCK 1 , ~I~E~iA~NK,' ~\\ ~/11/2ooo AI~SIiA WATER & WASTEWATER SOA~: 6go~ DEBARR ROAD, SUITE ZB ' ANCHORAGE, AK 9950b. * PHONE (907)3~7-0i79 ° FAX (907)350-SZ~6 1 = 1 00' .E~AL DESCE,PT,ON: SUSITNA VIEW SUBDIVISION; LOT 11, BkOCK 5, tYPE OF WORK: SITE PLAN FOR TANK REPLACEMENT DESIGN OF SEPTIC TANK REP~CEM~NT ;,~.~ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE E~EW MAILING ADDRESS LEGAL DESCRIPTION ! DISTANCE TO: /~ ~ Manufacturer ~ IF HOMEMADE: Well DISTANCE TO: 100 I 4 DISTANCE TO: Inside length Dwelling Foundat~ Total len~t~f lines Material beneath tile Dwelling70 t Materi~ ~.~_/ W dth Material ~ Nearest lot line Trench ~d~ Width Depth Crib diameter Crib depth Total effective absorption area Building foundation Nearest lot line NO. OF BEDROOMS PERMITNO.7 ~ No, of compartments~, Liquid depth PERMIT NO, Liquid capacity in gallons PERMIT NO. Distance between lines~/~ inches Total effective absorption area Depth Driller Distance to lot line PERMIT NO. DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PiPE MATERIAL~ ~_~ SOi L TEST RATING INSTALLER REMARKS 7L~-013 (~ev. 3/78} ~ DATE LEGAL (:ff;'F:' L,, I L-]::t f4 T _. L' '- FIT ]' · ' ' "--- .....I' '"j; ]"¢PE ()F: SOIL RE:Z()I:;.:D:T ): ON :;:',- Ed ... : TRENCH f"li::lX)]'"lUf'] NU["IE:EI;;: r.3F: E,E.E.f ...... IL. = r l,- E,R. - 1 ..... .::,ult.. f?.!:::l-i:'If.,II]i (,:-;1'.) ......... THE RE);:!U i RED '.:?, l ZE OF:' TFIE ~. U J.L. FIE:f;~;ORF'T, ~ . -- B ........... :::L ,,~I~ ~ C];~ ~:;:: E"::~ ".d EEL E .... THE I_.LI,I-~ I f I [:,I f'IENS I ON ;{ :;~; THF I. FNG-f'H ( I N F'EET) OF THE -f'F~:ENE:H - [::' !}RF:I:!: hlF' ]] ELI;!,. THE DEf:'TFI Cfi:' i::l TRENCH Of:;;'. f:'I-f' ]L.:X 'THE £:,):STI:IN(]:E E',ETHEEN TFIE :51..II:Rf::'FICE ElF THE 3P)r'~UNE:, FiND ]"f.lE E:OTI'OI',I OF: TI-.tI:.!; E:';::.::L'::I-';f',,,'i::IT;(OI'..I ,:]]ZN FEET). THERE I ::'.!; NO SET I.,1:( DTH F:'OR TF~:EI'.,ICHEE;. THE C~f;;:F;t'v'Ei:.. E:,EF'TH Z ~.~; THE f,11 N I MUM [:,EF:'TH OF E. ff:~:ig,/EI.._ E',ETI4EL:]'.,I THE '; i TF;'i:::II t . F' I F:'fi!] ei'.,l[:, THE E',OT-f'OM Eft:: 'FI:';E E::-;iI]]:I:I',,,'I'"-'I"I' ]: ()1'.] ( );['..! F;EET ). ::':; ltl);_. [:,EPFtRTMENT DUI-;;::( ?.,IG THE F'EI:,~:M 3; T I::~PFI_ Z L";I:II'.,IT l II...· THE f;?·E%f:'ON'_:;): E: ! L ); T'¢ TO ]] Nf::OF~:M - - ·':'" Lri'.,IS]-FiLL~;iTICd'-,I INSF'EC-I'IONS 'iF: FIN"r' I:I:ELL.;:, R[:,..]·RCI:":]?·,Ft' TO 'rHI:5 F,~ If fl ~ F:ff4i:) NlJftE~EF~: Ol:::' I'-.':E2::';IDENCES THF:IT ]"hiE HELL f4ILL_ :L[SE~ ~O 2C~L"~ F'EET FROM la PUBLIC HELL. DEI='EN[:,ING I...!F'()hl THE T'¥'PE OF' PI..IE:L.I(]: !,.filL! 'HELL. L. EIG'_:J; RRE RIE).'.-:!UIRE[:' FIND MU'.::;T 8E RE]'URNED' TO THE' [:,EPF:IRTP'Ili.:.]",!]" !4I]'H!N E:(3 t]:,F!"r'!~; OF THE H[CL[.. COMPLETION. OTHER F?.EL::!LIIf~:EME["~T'Z; MFI'T' F]F'F'L'·r'. GF'EC:IFIC:FfFIONL:~ F:II'·,ID CONSTRLICTI()I",! [)IF:I(3RFIH:~; I::IRE F:I'v'F~ILI:~BLEE TO INSURE PF4:OPER IN:E;TFII..!_.FYF]:ON. I C:ERTIF'-t TFIFIT :t: I RM FI-:tMILZRI:7: .t,i:ITH THE RE~;!UIREMENTE; FOR ON-SITE :5[El,i:Ef;..'S FIN(:, I.,.IEL.L.?:: FOR-FH 8'4 THE P'IUNICI PFIL. I T'¥' OF RNCHORI::IGE. 2: I WIL.L INSTf:I[..L THE S~r'S'I:EM IN RCE:OF:'.[:,RNCE 1.4iTH THE (::ODES· ]~:: I UNDERSTRND TI"fRT '[HE ON-SITE S[Et.,.IER S"?:STEM f"lFl~r' [~:E~/~L.IZRE EI'.,ILI::II:~:G[i}'IENT If:: THE RE:?:;I[:,EI'.,kZE ];:5 REMOD[.:.;L. ED TO IhlCLIJE:,E MORE THFIN 4 E:EE:,I:;b3C~ME;. )' :-.: -7'9 ..' / .L SIX INCH WATER WELL DRILLED AND CASED OUT TO THE DEPTH Of 175 ~o~ojbo DRILLED AT The Rate OF $1~.00 PER FOOT. ProPErtY OWNEr I~o Ct~2T~S ~.ZTOR 344-6143 1845 C_J. nd~ ~ ~3~rm 99507 LOCATION OF WELL SITE £/-_- RJk: %_U,; fmc 170 ~ee.6 .eh.e. &.,z~r~aZon. clmn4ed .so~e~ha.t. 7,~or~ 172 .co 175 ~e~c.i ~ ~o.zo~ ,~.;ze Co.o~ o~L ~m~Z~r~: g19.00 X 175 Fee;a; g3325.00 [to Cdw~e ~o.z ge.U. Sea. L. COST INCLUDES ALL LAbOr AND MATERiaL FOR COMPLETION Of SAID DrILLINg. write CheCK PaYaBLE TO Rampart DriLLINg works for The SUM OF $3325°00 ThaNK YOU VERY mUCh. BERNie CLAUS OF RAMPART DRILLING WORKS DAT~ I]~:~J~ 30~h.; 1979 SERVICE CHaRGEOF 1~% PER MONTH WILL BE ASSESSED DN--PAST DUE ACCOUNT$. , July 24, 1978 R&M No. 851130 Real Estate Corner 555 W. Northern Lights Blvd. Anchorage~ Alaska 99503 Attention: Jim Arnesen Subject: Soil Investigation for Sanitary Sewer System, Lot 11, Block 3, Susitna View Estates Subdivision, Anchorage, Alaska Dear Mr. Arnesen: At your request of July 10, 1978, we conducted a subsurface soils investi- gation at the proposed location of the sanitary sewer system on the subject lot. The investigation complied with those procedures required by the Muni- cipality of Anchorage Department of Health and Environmental Protection. This investigation, which was accomplished on July 18, 1978, consisted of a test hole drilled to'a depth of 18 feet below the existing ground surface. The test hole was sited according to your instructions and its location is shown in attached Drawing A-01o Drilling was accomplished with a rotary drill rig using continuous flight solid-stem auger with an outside diameter of 6 inches. A sample was taken at the depth shown on the soils log in Drawing A-01. The sample will be held in storage at our lab for approxi- mately six months. In addition, all material brought to the surface by the augers was continuously monitored by an experienced engineering geologist. The topography at the drilling site is generally gently-sloping. At the time of the investigation the site had original vegetation consisting of spruce and alder. The top of the test hole was located at original ground surface. The soils encountered in the bore hole are shown in the test hole log in Drawing A-01. This log displays specific conditions encountered at the test location. However, subsurface conditions may vary in other parts of the lot without any apparent surficial evidence of the change. Groundwater and bedrock were not encountered. At the time the hole Was drilled seasonal frost was not present and permafrost was not encountered. A percolation test was performed within the bore hole at the depth shown in the attached Table 1. All depths were measured from the-%op of-the hole. The data in Table 1 show average infiltration from the depths indicated t~ the bottom of the hole. The measured percolation rate was 9.1 minutes per inch. BORING NUMBER Date Completed: 7-18-78 SOIL DESCRIPTION ORGANIC SILT Br__own, Dry,___Medium Dense SILT W/TRACE GRAVEL (ML) Brown, Dry, Medium Dense 0.5I 3.5I SILTY GRAVEL W/TRACE SAND (GM) Few Cobbles Brown, Slightly Moist, Very Dense 6.5' LOCATION SKETCH No Scole T.H.-1 172nd Street SANDY GRAVEL W/TRACE TO SOME SILT (GP-GM) Brown, Dry, Dense 18~T.D. No Water Table Encountered. NOTE; DISTANCES SHOWN ARE APPROXIMATE A~D HAVE NOT BEEN MEASURED 8Y SURVEYING METHODS. EXPLANATION ORGANIC MATERIAL Little Vis~ble Ice 0:10' Vx I~'Ss, ?'2, 57. I°/o, 85.9 pcf ~-~P~OX. STt~ATA CHANG~ BEDROCK G~OU, V~ ~ TYPICAL SOILS LOG ~.B-AFT£R BO/~ING SAMPLER TYPE SYMBOLS .see abo~,L' SOILS LOG /J LOT 11, BLOCK 3 SUSITNA VIEW ESTATES ANCHORAGE, ALASKA PROJ. N0851130 ~ TIME ELAPSED TIME TABLE I PERCOLATION TEST Jim Arnesen R & M NO. 851130 FEET DROP IN INCHES 10:30 10:31 10:32 10:33 10:34 10:35 10:36 10:37 10:38 10:39 10:40 10:45 10:50 10:55 11:00 11:20 11:30 1 2 3 4 5 6 7 8 9 10 15 2O 25 3O 5O 6O 2.0' 2.0' 2.0' 2.0' 2.05' 2.05' 2.05' 2.05' 2.1' 2.1' 2.15' 2.2' 2.25 2°30' 2.31' 2.5' 2.55' 0 0 0 0 0.6 0 0 0 0.6 0 0.6 0.6 0.6 0.6 0.6 1.2 0.6 6.6 Inches Total Drop 9.1 Minutes Per Inch February 2, 19f~2 Lot 7 - Sus£tna ~lew Estates To Yrnom ~t May Concern~ Lot 7 of the Susitna Vi(~w Estates must have a 100 foot pro- tectod creek s~'L-bac5~ on both sides of the creek and no sep- tic tank or drainfie!d c~n encroach into ~l~is protected area. Also, '~he On-site investigation shows slopes 5[reater %hah 25%° A proposed developer ~nust havre lO,O00 ~c!uare feet less than 25% as to install an on-site s~ptic, system. Sincerely, John W. Lynn I~nviromnC~ntal L~_,./ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVII~N~'ff~I~I~,~.~(~'rAIGO~.N CERTIFICATE OF INSPECTION FOR HEALTH AUTH~I~VAL o. s.w.. 264-4720 ' GENERAL INFORMATION L~ (a) Legal~o~Description,~ ,include~lo,, block,~ subdivision,~_~section, to~nship,~ range)~~ Location (address or directions) (b) Applicant Name :~:~ ~/~ Telephone:Home ~:-~// Bu~ine~8 Applicant Address (c) Applicant is (check one): Lending lnstitution~ Owner/builder ~; Buyer ~; Other ~ (explain); (d) Lending Institution Telephone Address (e} Real Estate Company and Agent , Address Telephone (f) Mail the HAA to the following address: TYPE OF RESIDENCE Single-Fami[y~ Multi-Family [] Number of Bedrooms Other WATER SUPPLY Individual Well,,~ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite/~ Public [] Community [] Holding Tank [] Note: If corn m unity well system, must have written confirmation fro m the State Department of Environ mental Conservation attesting to the legality and status, Page 1 of 2 72-025 (11/84) ENGINEERING FIRM PROVtDIN~-G'~INSPECTIONS, TEST~i FILE SEARCH, DA~A AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage flies and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. ~. - .. Engineer's Seal Approved for --/-'¢/~" bedrooms by .. . Approved ~/~ Disapprovec~ Terms of Conditional Approval Conditional Date CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending' institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct in.¢ ~ections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 {11/84) MUNICIPALITY OF ANCHORAGE (MO~"Y HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Descri~~ WELL DATA Well Classification __~ IiA, B, C, D.E.C. Approved (Y/N) Well Log Present (Y/N) ~-,-~ Date Completed ~ Yield Total Depth I"~""' Cased tO ,J'~' Depth of Grouting Static Water Level ,~3 I Pump Set At Casing Height Above Ground ~ _~,'. ~. Sanitary Seal on Casing (Y/N) Electrical Wiring in Conduit (Y/N)~-- Depression Around Wellhead (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot } CO ! "~ ; On Adjoining Lots To Nearest Edge of Absorption Field on Lot l'~)l'~" ; On Adjoining Lots To Nearest Public Sewer Line ~/..~O/t~'~-~ To Nearest Public Sewer Cleanout/Manhole ~,,/~2/'¢2~,¢¢'¢ To Nearest sewer Service Line on Water Sample Collected by ~ _~,o _~___~,- ~ ~'"~"'~4~'~¢~ ~'~ ;Date Water Sample Test Results I . . ~.,..~,_ Comments ~_~ ~;,'~ ;~ ~-.,~..,' B. SEPTIC/HOLDING TANK DATA Date Installed ~ Size I ~..~"'~ No. of Compartments Standpipes (Y/N) %~ Air-tight Caps (Y/N) ~::r.~ Foundation Cleanout (Y/N) . ;~ Depression over Tank (Y/N)/~4:~ Date Last Pumped Pumping/Maintenance Contract on File (Y/N) ~,~ ; for Holding Tank High-Water Alarm (Y/N) ~'//.~. /' - - - . Temporary Holding Tank Permit (Y/N) Separation Distances from Septic/Holding Tank: TO Water-Supply Well TO Property Line To Water Main/Service Line To Building Foundation To Disposal Field To Stream, Pond, Lake, or Major Drainage Course Comments Page I of 2 72-026(11/84) ABSORPTION FIELD DATA Soils Rating in Absorption Strata Width ct Field t Gravel Bed Thickness Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well //~)O /'"~ To Building Foundation 7~/:~/'¢' Lot ./~/¢/b/~C ' To Water Main/Service Line __ / ~' O / '-~ To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area . To Property Line To Existing or Abandoned System on ; On Adjoining Lots / ~4:> I~ '~' To Cutbank (if present) Comments Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Comments Dimensions Manhole/Access (Y/N) "Pump Off" L ~/el-'~ ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I havc,ch.~ck~erifi/e~l, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. S i g n~ _~/~-~ -,'"~./¢" .. Date Company ~~ ~¢- MOA No. R ei iNo. Date of Payment /~ Amount: $ ~ ~ ~1%'"" ~ '"? ' ¢' Engineer's Seal - ~ W. Benson Blvd. Suite ~ PENINSULA ENGINEERING Anchorage, Alaska 99503 (907) ~61-~107 December 30, 1985 Mr. Curtis Elton 17115 Feodosia Drive Anchorage, Alaska RE: Lot 11 Block 3 Susitna View Est. Adequacy Test of Septic System Dear Mr. Elton: At your request we have performed an adequacy test on the above referenced septic system. The test was performed by adding 600 gallons of water to the absorption trench and monitoring the results for two consecutive days. Water was added at 7 gpm from the well on both days, which served as a good test of the well delivery. The system functioned adequately for a 4 bedroom capacity and the well delivery was good. A tabulation of the test results follows. Date Time Tank Trench Quantity 12/17 0 18" 52" 0 20 18.5 60 140 60 19 70 420 85 19 74 600 12/28 0 24 53 0 30 24 66 210 50 24 71 350 85 244 75 600 12/29 0 30 53 0 If I can be of any further assistance please call. Sincerely, Wayne He~erson, P.E. WH:js PENINSULA ENGINEERING CONSULTING ENGINEERS TO: Date: 440 WEST BENSON BLVD., SUITE 206 ANCHORAGE, ALASKA 99503 PHONE: (907) 561-5107 Re: Engineering Other [] Project No.: LEGAL DESCRIPTION: SERVICES: Total $ -' ~-' ~' ~ All accounts are due upon receipt of services by PENINSULA ENGINEERING. Credit accounts not paid within thirty (30) days following receipt of service will be charged 2% per month on the unpaid balance, I hereby acknowledge receipt of the payment terms stated above, PLEASE PAY PROMPTLY copies of the above described Report and understand Signed Date -~ INSPECTION APPOINTMENTS TIME TIME TIME DATE OATE DATE MUNICIPALITY OF ANCHORAGE  DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION  825 L Street - Anchorage, Alaska 99501 ( ENVIRONMENTAL SANITATION DIVISION Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND sEWER FACILITIES DIRECTIONS: Complete all parts on paue 1. Incomplete reques~ will not be proceed. Please allow ten (10) days for processino. PHONE 1. PROPER YOWNER MAILING ADDRESS PROPERTY R~IDENT (If different from above) PHONE 2, BUYER MAILING ADDRESS ] PHONE MAILING ADDRESS I PHONE 4. REALTOR/AGENT A,U.e AOO SS 5. LEGAL DESCRIPTION i..O'P !1 .<7 r' nc :TR EET LOCATION NUMBER OE~OEOROOMS TYPE OF RESIDENCE [] One [] Four ~.__ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY ~... Three [] Six [] Other WATER SUPPLY [~ INDIVIDUAL* [] COMMUNITY [] PUBLIC UTI LITY * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975, For wells drilled prior to that date, give well depth (attach log if available.) 8, SEWAGE DISPOSAL SYSTEM '-~.!NDIVIDUAL/ON-SITE** [ ~/~ YEAR ON-SITE SYSTEM WAS INSTALLED. [] PUBLIC UTILITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED, 72-010 (Rev, 6/79) I ~ THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE ,,... SI NG L E FAMILY [] MULTIPLE FAMILY 2. WATER SUPPLY ~.' INDIVIDUAL [] COMMUNITY [] PUBLIC UTI LITY Connectio9 Verified 3. SEWAGE DISPOSAL SYSTEM [] INDIVIDUAL/ON -SITE []PUBLIC UTILITY Connection Verified []Septic Tank or []Holding Tank ~l~¢_C~f' Tank is homemade Size: give dimensions: TYPE OF TANK TOTAL ABSORPTION AREA 4. DISTANCES WELL TO: Absorption Area to nearest Lot Line NUMBEROFBEDROOMS [] ONE [~-~. TH R EE [] FIVE [] TWO [] FOUR [] SIX PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED ~/'~ PERMIT NUMBER DATEINSTALLED INSTALLER Line [] OTHER SOILS RATING MANUFACTURER Nearest Lot Line 5. COMMENTS EJ~J-'~APPROV ED FOR _~ BEDROOMS CONDITIONAL APPROVAL (letter must ac DISAPPROVED DATE Lany certificate) 72-010 (Rev. 6/79) GREATER ~2-~CHORAGE AREA BOROOGI~ 104 West l~orthern Lights Boulevard Anchorage~ Alaska 99503 S- 19S'6 Plat Status: Final Date~ June 17, 1970 BOROUGH: Engineer / Health Department Public Works Department Sand Lake Fire Department .School District Street Names Tax Assessor Alaska Department of Highways Alaska Railroad Anchorage Natural Gas COrpo Central Alaska Utilities Chugach Electric Association CITY OF ~J]~iOP~,GE: Fire ilarshal }~nnicipal Light & Power Department Property Management Officer Public Works Department Telephone Utility Traffic Engineer Water Utility GAB Teleconmmnications~ Inc. Matanuska Electric Association Matanuska Telephone Association Assistant Superintendent of Mails Re: Subdivision / ~I~C~I~lY~ Description of Property: Se~ attached plat Bob Pennington Gentlemen: Petition has been received by the Greater Anchorage Area Borough Planning and Zoning Commission for the proposed Subd. of subject property.' Attached is a copy of ~e proposed plat. Wi. 1 you please submit your comments in writing~ specifying any easements or other requirements that your department or agency may need. If we do not hear from you by Jul~..~., 19~0 you do not wish to submit any comments. · we will assume that If you have no further use for the attached print, please return it with your comments. Planning Department Enclosure