HomeMy WebLinkAboutSUSITNA VIEW ESTATES BLK 3 LT 11Onsite File
#020-091-27
Note in file indicates 1979 field may be in
groundwater. Prior to issuing a drainfield upgrade or
COSA, a test hole shall be provided within 30 ft of
the 1979 drainfield to confirm separation to seasonal
high groundwater.
N U UU. LLD 00 U U U
L
1laN27MY
Municipality of Anchorage
On -Site Water and Wastewater Program • (907) 343-7904 Page 1 of 3
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP191134 PID Number: 020-091-27
Dwelling: 0 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New Upgrade
Name:
David Irons & Ann Rappoport
ABSORPTION FIELD
❑ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
17053 Aries Ct, Anchorage, AK, 99516
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
345-3822
4
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
Susitna View Estates 3 11
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ft2
Ft.
Well
>100'
N/A
N/A
N/A
>25'
TANK ❑Q Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer
Anchorage Tank
Capacity
1250 Gal.
Surface Water
>100'
N/A
N/A
N/A
Material
Number of compartments
Lot Line
>5'
N/A
N/A
N/A
Epoxy Coated Steel
2
NA
Foundation
>10,
N/A
N/A
N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain
None
Noted
Gal.
Remarks Tank replacement only under this
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
permit.
Pump make and model
Electrical Inspections performed by
Installer
PIPE MATERIAL House to tank D3034 Tank to D3034
drainfield
Wilco Contracting
Drainfield Existlnq CO/MT
Inspector J. Williams
BENCHMARK (Assumed elevation) 100 ft
Inspection 15` 4/30/19 nd
Location and description
2
3rd 4"'
Bottom of siding.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
�
Conditional Approval: Date
w® .••'"'��
�"'•'
�®
: • 49th
X.... }, ............. ... ..%..... e
'Z J'� li
0. �...mn......m...w...........�..
0�n MICHAEL E. ANDERSON
D
Qj
No. CE -4381 ?
e���(�,p''•. 6/12/19 ..•'°�t����
......•
�
Approved ��(1(i�Di�Z Date 3 j j a0 2U
1m FO • .... � ®®•
T`m �ck_&1?
�®e®®0®®S0®®s's
11 wNccuui i MUPUI i_y- i- i c.uuc
SUSITNA VIEW ESTATES, BLOCK 3, LOT 11
PERMIT # OSP191134 PID # 020-091-27
i
i
I EXISTING WELL
LOT 10
4-BDRM HOM `
A
Fco
t
2cot 1,250 -GAL
svi • SEPTIC TANK EXISTING WELL
Sv2
zcoz
LOT 11
EXISTING ABSORPTION
TRENCH. LOCATION
PER MOA FILES
UNSUBDMDED
A B
2C01
67.4
66.0
SV1
70.7
69.6
SV2
77.1
76.5
2CO2
80.8
79.9
MICHAEL E. ANDERSON :a
SAW 0 50 100
No. CE -4381 e
�'. 6112119 +FEET
4f, 5
, �E51 ®�®�� 1"=50'
LEGEND
CO -CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEAN(
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
SUSITNA VIEW ESTATES B3 L11
PERMIT # OSP191134
ENGINEERING
PID # 020-091-27
PROFILE AS -BUILT
(NO SCALE)
R=20.00'
W
ro
0
W
LL -
13
i
13
30.0'
L=16.49'
R=180.00'
S�N
p0
5.5'x8.4' /
BALCONY
\ t
96.4' \
' 1.0' CANT \ \ \
o Lot 11
Z 42,801 s.f. \
GRAVEL DRIVEWAY\
12.2'x16.2' SHED
3� ENCROACHES 2.0' ONTO LOT 10
N,g3N WELL
• o. w .1
zs o
CHAIN—LINKI FENCE
w.
°'° °' ss Lot 10
2 STORY RESIDENCE
Ec s
p w/ BASEMENT
m
\ CENTERLINE OF GAS/
LINE EASEMENT
100' PROTECTIVE
\ WELL RADIUS
SEPTIC PIPES
�tC
W
GAS LINE EASEMENT
25BUILDING SETBACK ,
Unsubdivided
10' UTILITY
PLOT PLAN AS BUILT —2L SCALE 1" = 50' GRID SW 3336 Project
No. 19-140/A2
11500 Daryl Avenue, Anchorage, Alaska 99515-3049
Lang & Associates, in C. , (907) 522-6476 Phone
(907) 522-4625 Fax
0000Op�O
oo OFA / 0�4
Professional Land Surveyors kenOlongsurvey.com
y jonathanOlongsurvey.com
o
G R�' �5�0
I hereby certify that I have surveyed the following described properly:
LOT 11, BLOCK 3, SUSITNA VIEW ESTATES (PLAT No. 70-287)
p * : 49TH �* 0�
�" "•"' .6
Anchorage Recording District, Alaska, and that the Improvements situated thereon are
within the property lines and do not encroach onto the property adjacent thereto, that
�
I{�/,
no improvements on the property lying adjacent thereto encroach on the surveyed
premises and that there are no roadways, transmission lines or other visible
easements on said property except as Indicated hereon.
p' ....KEN. . ETH .: x i
Q' Q
Dated this the ° Day of N� 2! '1 at Anchorage, Alaska
•.LS -5202.•' yJp�
Opp p . . . • . . . . o d
QO"OPESSIONAI. o
It Is the responsibility of the owner to determine the existence of any easements,
�DOO000�
covenants, or restrictions which do not appear on the recorded subdivision plat.
AECC963
Engineer:
Legal Description
Parcel ID:
Permit:
Report Type:
IVIU UIPMILy vt 1A11U11U1d9U
On -Site Water and Wastewater Program
P.O. Box 196550 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
Review Comments
FORGE ENGINEERING
EPLANS SUSITNA VIEW ESTATES BLK 3 LT 11
02009127000
OSP191134 SepticTank
As Built Review
r1 n
,1
llepartin ent
1/28/2020
Completed By: T.Ecklund
The application has been reviewed and the following comments have been generated. These are to be satisfactorily
addressed prior to MOA approval:
1. Please address provisions to the permit, letters of non -objection, field encroaching on GW and required to confirm
slope to drainfield
2. Please provide an as -built survey
1) See attached letter of non -objection from Enstar. Slope to drainfield confirmed (no standing water in
double cleanout after tank, and positive flow can be seen down pipe.) Request to address field to GW
separation at time of future COSA.
2) See attached survey.
ENSTAR
Natural Gas Company
June 26, 2019
Ann Rappoport and David Irons Family Trust
17053 Aries Court
Anchorage, AK 99516
Re: Letter of Non -Objection — Absorption Trench Encroachment
Dear Mrs. Rappoport and Mr. Irons,
ENSTAR Natural Goa Company
A DIVISION OF SEMCO ENERGY
401 E. Intonational Airport Road
P. O. Box 190288
Anchorage, Alaska 99519-0288
(907)277-5551
ENSTAR Natural Gas Company (ENSTAR) has no objection to the existing absorption trench, within the
twenty foot (20 FT) wide natural gas easement within Lot 11, Block 3, Susitna View Estates, according to
Plat No. 70-287, Records of the Anchorage Recording District, Third Judicial District, State of Alaska,
subject to the following special conditions:
Acceptance and use of this letter of non -objection by yourself, your heirs, your assigns, or your
successors, will constitute agreement to the following typical stipulations:
• There is an existing 12 inch natural gas transmission pipeline within this natural gas easement.
o No reduction of grade or increase of grade in the easement will occur without the
prior written approval from ENSTAR Engineering.
o All impermeable structures or surfaces must maintain a 36 -inch clearance to ENSTAR
facilities.
o ENSTAR will not be responsible for any expenses related to underground, surface,
asphalt, concrete, curb, absorption trench etc. repairs if ENSTAR is required to
excavate to access our facilities. Said costs will be the responsibility of the owner of
the subject property at time any special construction expense is incurred.
o Upon transfer of the property to another owner, the new owner shall apply for anew
Letter of Non -objection, subject to an inspection of the premises by ENSTAR.
• Landowner/Contractor working near ENSTAR gas facilities shall contact the Alaska Digline, Inc.,
(907) 278-3121 or 811 for line locating two (2) business days prior to any related excavation.
This service is free of charge.
• ENSTAR will be held harmless, now and forever for any damages or injury to any person or
property as a result of this encroachment.
Any ENSTAR facility damaged or destroyed, as a result of this encroachment will be repaired at
no cost to ENSTAR.
• Any costs incurred by ENSTAR for special construction necessitated by this encroachment will be
borne by the land owner.
0 All applicable safety code regulations will be observed and maintained.
Letter of Non -Objection LII B3 Susitna View Estates 612612019
• This letter of non -objection will in no way preclude ENSTAR from full use and enjoyment of its
rights within any portion of its right-of-way.
• This letter of non -objection shall not be in effect until the signed acceptance is received by
ENSTAR.
Sincerely,
Andrew Fraiser
Right -of -Way & Permitting Supervisor
ENSTAR Natural Gas Company
Accepted by:
Trustee for the Ann Rapf3oporfand David fro ily Trust
(2=Pzx::r,, -, -
l
Signature CJ
Date
'� (�" I r 0-\ "')
l��
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP191134
Work Type: SepticTank Upgrade
Tax Code Number: 02009127000
Site Legal Address: SUSITNA VIEW ESTATES BLK 3 LT 11 G:3336
Site Mailing Address: 17053 ARIES CT, Anchorage
Owner: RAPPOPORT ANN & IRONS DAVID
Design Engineer: FORGE ENGINEERING
This permit is for the construction of:
❑ Disposal Field O Septic Tank ❑ Holding Tank ❑ Privy
Effective Date
Expiration Date:
Lot Size in Sq Ft
Total Bedrooms:
lieiia!'fllttrnL
4/30/2019
4129/2020
42801
❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
1. A letter of non -objection shall be provided from the gas company for the existing field located within the gas'
line easement prior to inspection report approval.
2. The septic system shall not be installed within the 25 ft wide building setback.
3. Confirm that the piping between the tank and drainfieid is adequately sloped down towards the drainfield.
4. MOA records indicate that the existing drainfieid maybe in roundwater: Priorto issuance of a. COSA, an
engineer shall confirm that the field is not in groundwater.
Received By.
Issued By:
j- I k�'L
Date:
Date: .3p t GI
!ll
??v8py 27US8
MUHM PAUTY OF ANCHORAGE Z/!!'ROVAWNVS
Community Development Department Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On -Site Water & Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 020-091-27
Property owner(s) David Irons & Ann Rappoport
Mailing address 17053 Aries Court Anchorage, AK 99516
Site address Same
Day phone 345-3822
Legal description (Sub'd., Block & Lot) Susitna View Estates, Block 3, Lot 11
Legal description (Township, Range & Section)
Lot Size 42,801 Sq. Ft. Number of Bedrooms Four (4)
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
F-1
Initial❑
Single Family (SF)
❑X
(w/wo ADU)
Septic Tank
❑X
Upgrade FZ
Duplex (D)
❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES
A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is, in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: �13tob Waiver Fees: N
Date of Payment: a` -t Iq Date of Payment:
Receipt Number: j, D /-75-&D
-75- Imo' Receipt Number:
Permit No. dOP1 `Z 1 �J�`� Waiver No.
Permit App_.;- : . �. c
PO BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
April 24, 2019
MOA Development Services Dept, On-Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: Susitna View Estates, Block 3, Lot 11 – 17053 Aeries Court
Septic System Design
Dear On-Site Services Engineer:
The septic tank on the subject lot is leaking and must be replaced prior to the issuance of a COSA
for the property. The attached site plan identifies the location of the home and the existing well
and septic system. No conflicts exist between this proposed septic tank and any other well or septic
system, whether on this lot or adjacent lots.
The new septic tank will be placed a minimum of 5’ from all deck or stairway foundation supports
and all lot lines. The existing septic tank will be decommissioned in accordance with Municipal
Code.
The existing well on the lot is shown. The placement of the new septic tank will not encroach into
surrounding protective well radii. Please refer to the attached plan sheet for the septic design. If
this design is followed, there will be no adverse impacts to adjacent properties.
Sincerely,
Michael E. Anderson, P.E.
4-24-19
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191134, Rebecca Carroll, 04/30/19
x x x x xFCO
10050 0
FEET
1"=50'
4-BDRM HOME
NOTE:
NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE
PROPOSED SEPTIC SYSTEM
ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS
PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC
SYSTEMS.
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
LEGEND
SUSITNA VIEW ESTATES, BLOCK 3, LOT 11
4/30/19FEODOSIA DRIVE20' GAS LINE EASEMENT
CENTERLINE OF GAS
LINE EASEMENT
ARIES COU
R
T
10' UTILITY EASEMENT
EXISTING WELL
DECOMMISSION
EXISTING SEPTIC
TANK PER MOA CODE
NEW 1,250 GALLON SEPTIC TANK.
SECURE TANK AS NECESSARY
TO PREVENT FLOTATION. SEE
DETAIL
2CO
2CO
SV
SV
EXISTING ABSORPTION
TRENCH. LOCATION
PER MOA FILES
25' BUILDING
SETBACK
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191134, Rebecca Carroll, 04/30/19
SEPTIC TANK BALLAST
(NO SCALE)
SUSITNA VIEW ESTATES, BLOCK 3, LOT 11
BOUYANCY CALCULATIONS:
(NEGLECTING WEIGHT OF TANK)
BOUYANCY FORCE ON EMPTY TANK:
1,250 GAL CAPACITY x 8.35 LB/GAL = 10,438 LBS
WEIGHT OF CONCRETE BALLASTS:
8'x2.5'x2.5' x 150 LB/FT3 x 2 = 15,000 LBS
WEIGHT OF SOIL ABOVE TANK:
4'x8'x5' x 145 LB/FT3 = 23,200 LBS
SAFETY FACTOR: 3.6
EYE BOLTS EVERY 2'
1
2" CABLE W/ TURNBUCKLE
TIGHTEN OVER TANK
8' L X 2.5' W x 2.5' D
CONCRETE BALLAST
1,250 GALLON SEPTIC TANK
4.0
CONCEPTUAL ONLY. OTHER METHODS TO SECURE
TANKS WILL BE PERMITTED AT THE DISCRETION OF THE
ENGINEER.
NOTE:Michael E. Anderson
4831-ER
EGISTEREDPROFE S S I O N ALEN GINEER
4-30-19
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP191134, Rebecca Carroll, 04/30/19
View
Lot 11
Block 3
#020-091-27
MUNICIPALITY OF ANCHORAGE
MEMORANDUM
¢ -.z3-- o o /$
015 (Rev 9~97)*
Municipality of Anchorage Poge 1 of 2
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 Anchoroge, Alaska 99519-6650 Telephone: 545-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permlt Number:, SW000067 PID Number: 020--091--27
DAVID IRONS & ANN RAPPOPORT WastewaterSystem: · New [] Upgrode
Address:
17055 ARIES CT, ANCHORAGE, AK 99516 ABSORPTION FIELD
NO. of Bedroome:zl' DDeep :~ OUler7~r=d~''
Ph°n":.907.(' ) 545-5822 Tr=nch n Shollow Trench r'lsed nUound
$~;I Rc~Jng: , Tot~ De~th fr~m Gl §rode:
LEGAL DESCRIPTION o../~..
Ft.
1I : sUS~TN~3(~_. ".~
.~ ~ TANK
SEPARATION DISTANCES · ~p~. ~ .o~n. ~ ~.~.~...
~ s~u.. T..k ~..r u.= ANCHORAGE TANK 1250
Well 1 OD'+ 100'+ -- 25'+ STEEL
Su,OCewoter 100'+ 100'+ -- - LI~
Uno 5'+ 10'+ -- -- --
5'+ 10'+ _ _ _ ~p o." r~ ~: "~ I~ .=~ =~=~ ~
Foundotion
Droin = NONE KNOWN
I I
~.mo~..: - ~o C~UCE ~EEP ~U.~ ~. BENCH MARK
- GROUNDWATER SEEPING IN ABOUT A FOOT ABO~ TOP SOUTH ~ST CORNER OF R~R DECK
OF TANK.
- APP~S TO BE R~ERSE C~OE FROM EXI~NG SERVICE 100.00
Ins~ions pe~ by: AWWC, INC. D~s: 1st 4/21/2000 ,
2nd s/~/2ooo ~ ~ .........
3~ ~.¢ ~ d ~I re A. ~rness~
~a~m~n~ o~ 8~lth ~nd ~um~n 8~i~ a~ro~al u~,,, .. ............. ..}~
Renewed and appmv~ by: 0 ~/_ ~. ~, Date: ~-~2- o~
AS-BUILT DRAWING
SWO00067 020-091-27
65.2,3 65.00
65.50 65.55
71,40 71.1.3
80.65 81,22
81.75 82.94
81.33 8,3.28
A B
DBL1 65,23 65,00
DBL2 65,50 65.55
ST1 71,40 71.13
ST2 80.65 81.22
DBL3 81.75 82.94
DBL,4 81.33 83.28
J.W.M. ~{
AI,AS~ WATER & WASTEWATER ,~[~: ~,:.~,t~ ]3:
~~=~==*~=~ CONSUkTANTS, INC.~==~=~-'~=~ 1 .....~ ~,~..,
DAVID IRONS a ANN RAPPOPORT (907) 345-3822 2 OF 2 ;_ '¢~'ei'r, t A~ess/ ~
~ ,~c..,,o,: '0~..~ ~-~ ..-"/fl
SUS~T.* w~w SUmWS~O.: ,OT ~..,OC, ~ %¢:,'., ........... -,;~k~"
AS-BUILT OF TANK REP~CEMENT '~%~
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Apr 17, 2000
Expiration Date: Apr 17, 2001
Permit Number: SW000067
Legal Description: SUSITNA VIEW ESTATES BLK 3 LT 11
Design Engineer: 0041 AKWater & Wastewater Consultant
Owner Name: Ann Rappaport & David Irons
Owner Address: 17053 Aries Court Total Bedrooms: 4
Anchorage, AK 99516-5316
ParcellD: 020-09%27
Site Address: 017053 ARIES CT
Lot Size: 42801 SQ. FT.
Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343~4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Date:
Issued By: Date: 4 - /7-00
ALASICA WATER & WASTEWATER
RECEIVED
April 1 l, 2000
APR 12 .000
MUNICIPALI¥¥ OF ANCHORAGE
:'qVIRONMENTA~. SERVICF$
Municipality of Anchorage
DepmCment of Health & Human Services
Division of Environmental Services
On-Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Tank Replacement Design for Lot 11,'Block 3, Susitna View Subdivision
To whom it may concern:
The existing 4 bedroom house is served by a private well and septic system. The existing septic
tank is collapsing and is in need of replacement. The new tank will be positioned 5 feet east of
the existing tank.
I am unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact me at 337-6179, or 244-9612. Thank you
for your assistanc~
Sincerely,///~/ /
., M.S.
Pre~ddnt
NOTE: Attached is a site plan drawing, a design drawing, and a 3 page construction
specification letter which are all part of the design package for this tank replacement.
6901 Debarr Road, Suite 2B - Anchorage, AK 99504 - Ph: (907)337-6179 - Fax: (907)338-3246
LOT ,4, BLOCK 1 I LOT 2, BLOCK 3 I mT ,a mr~r:~¢ ~;
SUSITNA VIEW EST. I SUSITNA VIEW EST. I S~J~S'iTN'.~ ~/l'~"Es~r
WELL LOCATED ON
~ ~ LOT 9. BLOCK 3
,.OT.~, BLOOK~ I ~OS~B.J.;~'~j. ~, / / B,.,S,T,,,A VIEW ES~-.
~ SEPTIC / / / ~--
c;.. ,/
'--..."' '"'" ~". '-~-/....~./" ~d. "..
~ LOT 2, BLOCK 1 ! .-k~ '~ \X~, ~ \ J ~
I LOMA ESTATES
LOT 1. BLOCK 1 , ~I~E~iA~NK,' ~\\
~/11/2ooo
AI~SIiA WATER & WASTEWATER SOA~:
6go~ DEBARR ROAD, SUITE ZB ' ANCHORAGE, AK 9950b. * PHONE (907)3~7-0i79 ° FAX (907)350-SZ~6 1 = 1 00'
.E~AL DESCE,PT,ON:
SUSITNA VIEW SUBDIVISION; LOT 11, BkOCK 5,
tYPE OF WORK:
SITE PLAN FOR TANK REPLACEMENT
DESIGN OF SEPTIC TANK REP~CEM~NT
;,~.~ MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street - Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME PHONE E~EW
MAILING ADDRESS
LEGAL DESCRIPTION !
DISTANCE TO: /~
~ Manufacturer ~
IF HOMEMADE:
Well
DISTANCE TO: 100 I 4
DISTANCE TO:
Inside length
Dwelling
Foundat~
Total len~t~f lines
Material beneath tile
Dwelling70 t
Materi~ ~.~_/
W dth
Material ~
Nearest lot line
Trench ~d~
Width Depth
Crib diameter Crib depth Total effective absorption area
Building foundation Nearest lot line
NO. OF BEDROOMS
PERMITNO.7 ~
No, of compartments~,
Liquid depth
PERMIT NO,
Liquid capacity in gallons
PERMIT NO.
Distance between lines~/~
inches
Total effective absorption area
Depth Driller Distance to lot line PERMIT NO.
DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s)
OTHER
PiPE MATERIAL~ ~_~
SOi L TEST RATING
INSTALLER
REMARKS
7L~-013 (~ev. 3/78} ~
DATE
LEGAL
(:ff;'F:' L,, I L-]::t f4 T
_. L' '- FIT ]'
· ' ' "--- .....I' '"j;
]"¢PE ()F: SOIL RE:Z()I:;.:D:T ): ON :;:',- Ed ... : TRENCH
f"li::lX)]'"lUf'] NU["IE:EI;;: r.3F: E,E.E.f ...... IL. =
r l,- E,R. - 1 .....
.::,ult.. f?.!:::l-i:'If.,II]i (,:-;1'.) .........
THE RE);:!U i RED '.:?, l ZE OF:' TFIE ~. U J.L. FIE:f;~;ORF'T,
~ . -- B ........... :::L ,,~I~ ~ C];~ ~:;:: E"::~ ".d EEL E ....
THE I_.LI,I-~ I f I [:,I f'IENS I ON ;{ :;~; THF I. FNG-f'H ( I N F'EET) OF THE -f'F~:ENE:H - [::' !}RF:I:!: hlF' ]] ELI;!,.
THE DEf:'TFI Cfi:' i::l TRENCH Of:;;'. f:'I-f' ]L.:X 'THE £:,):STI:IN(]:E E',ETHEEN TFIE :51..II:Rf::'FICE ElF THE
3P)r'~UNE:, FiND ]"f.lE E:OTI'OI',I OF: TI-.tI:.!; E:';::.::L'::I-';f',,,'i::IT;(OI'..I ,:]]ZN FEET).
THERE I ::'.!; NO SET I.,1:( DTH F:'OR TF~:EI'.,ICHEE;.
THE C~f;;:F;t'v'Ei:.. E:,EF'TH Z ~.~; THE f,11 N I MUM [:,EF:'TH OF E. ff:~:ig,/EI.._ E',ETI4EL:]'.,I THE '; i TF;'i:::II t . F' I F:'fi!]
ei'.,l[:, THE E',OT-f'OM Eft:: 'FI:';E E::-;iI]]:I:I',,,'I'"-'I"I' ]: ()1'.] ( );['..! F;EET ).
::':; ltl);_. [:,EPFtRTMENT DUI-;;::( ?.,IG THE
F'EI:,~:M 3; T I::~PFI_ Z L";I:II'.,IT l II...· THE f;?·E%f:'ON'_:;): E: ! L ); T'¢ TO ]] Nf::OF~:M - - ·':'"
Lri'.,IS]-FiLL~;iTICd'-,I INSF'EC-I'IONS 'iF: FIN"r' I:I:ELL.;:, R[:,..]·RCI:":]?·,Ft' TO 'rHI:5 F,~ If fl ~ F:ff4i:)
NlJftE~EF~: Ol:::' I'-.':E2::';IDENCES THF:IT ]"hiE HELL f4ILL_
:L[SE~ ~O 2C~L"~ F'EET FROM la PUBLIC HELL. DEI='EN[:,ING I...!F'()hl THE T'¥'PE OF' PI..IE:L.I(]: !,.filL!
'HELL. L. EIG'_:J; RRE RIE).'.-:!UIRE[:' FIND MU'.::;T 8E RE]'URNED' TO THE' [:,EPF:IRTP'Ili.:.]",!]" !4I]'H!N E:(3 t]:,F!"r'!~;
OF THE H[CL[.. COMPLETION.
OTHER F?.EL::!LIIf~:EME["~T'Z; MFI'T' F]F'F'L'·r'. GF'EC:IFIC:FfFIONL:~ F:II'·,ID CONSTRLICTI()I",! [)IF:I(3RFIH:~; I::IRE
F:I'v'F~ILI:~BLEE TO INSURE PF4:OPER IN:E;TFII..!_.FYF]:ON.
I C:ERTIF'-t TFIFIT
:t: I RM FI-:tMILZRI:7: .t,i:ITH THE RE~;!UIREMENTE; FOR ON-SITE :5[El,i:Ef;..'S FIN(:, I.,.IEL.L.?::
FOR-FH 8'4 THE P'IUNICI PFIL. I T'¥' OF RNCHORI::IGE.
2: I WIL.L INSTf:I[..L THE S~r'S'I:EM IN RCE:OF:'.[:,RNCE 1.4iTH THE (::ODES·
]~:: I UNDERSTRND TI"fRT '[HE ON-SITE S[Et.,.IER S"?:STEM f"lFl~r' [~:E~/~L.IZRE EI'.,ILI::II:~:G[i}'IENT If:: THE
RE:?:;I[:,EI'.,kZE ];:5 REMOD[.:.;L. ED TO IhlCLIJE:,E MORE THFIN 4 E:EE:,I:;b3C~ME;. )'
:-.:
-7'9 ..' / .L
SIX INCH WATER WELL DRILLED AND CASED OUT TO THE DEPTH Of 175 ~o~ojbo
DRILLED AT The Rate OF $1~.00 PER FOOT.
ProPErtY OWNEr I~o Ct~2T~S ~.ZTOR 344-6143 1845 C_J. nd~ ~ ~3~rm 99507
LOCATION OF WELL SITE £/-_- RJk: %_U,;
fmc 170 ~ee.6 .eh.e. &.,z~r~aZon. clmn4ed .so~e~ha.t. 7,~or~ 172 .co 175 ~e~c.i ~ ~o.zo~ ,~.;ze
Co.o~ o~L ~m~Z~r~: g19.00 X 175 Fee;a; g3325.00
[to Cdw~e ~o.z ge.U. Sea. L.
COST INCLUDES ALL LAbOr AND MATERiaL FOR COMPLETION Of SAID DrILLINg.
write CheCK PaYaBLE TO Rampart DriLLINg works for The SUM OF $3325°00
ThaNK YOU VERY mUCh.
BERNie CLAUS OF RAMPART DRILLING WORKS
DAT~ I]~:~J~ 30~h.; 1979
SERVICE CHaRGEOF 1~% PER MONTH WILL BE ASSESSED DN--PAST DUE ACCOUNT$. ,
July 24, 1978 R&M No. 851130
Real Estate Corner
555 W. Northern Lights Blvd.
Anchorage~ Alaska 99503
Attention: Jim Arnesen
Subject: Soil Investigation for Sanitary Sewer System, Lot 11, Block 3,
Susitna View Estates Subdivision, Anchorage, Alaska
Dear Mr. Arnesen:
At your request of July 10, 1978, we conducted a subsurface soils investi-
gation at the proposed location of the sanitary sewer system on the subject
lot. The investigation complied with those procedures required by the Muni-
cipality of Anchorage Department of Health and Environmental Protection.
This investigation, which was accomplished on July 18, 1978, consisted of a
test hole drilled to'a depth of 18 feet below the existing ground surface.
The test hole was sited according to your instructions and its location is
shown in attached Drawing A-01o Drilling was accomplished with a rotary
drill rig using continuous flight solid-stem auger with an outside diameter
of 6 inches. A sample was taken at the depth shown on the soils log in
Drawing A-01. The sample will be held in storage at our lab for approxi-
mately six months. In addition, all material brought to the surface by the
augers was continuously monitored by an experienced engineering geologist.
The topography at the drilling site is generally gently-sloping. At the time
of the investigation the site had original vegetation consisting of spruce
and alder. The top of the test hole was located at original ground surface.
The soils encountered in the bore hole are shown in the test hole log in
Drawing A-01. This log displays specific conditions encountered at the test
location. However, subsurface conditions may vary in other parts of the lot
without any apparent surficial evidence of the change. Groundwater and
bedrock were not encountered. At the time the hole Was drilled seasonal
frost was not present and permafrost was not encountered.
A percolation test was performed within the bore hole at the depth shown in
the attached Table 1. All depths were measured from the-%op of-the hole.
The data in Table 1 show average infiltration from the depths indicated t~
the bottom of the hole. The measured percolation rate was 9.1 minutes per
inch.
BORING NUMBER
Date Completed: 7-18-78
SOIL DESCRIPTION
ORGANIC SILT
Br__own, Dry,___Medium Dense
SILT W/TRACE GRAVEL (ML)
Brown, Dry, Medium Dense
0.5I
3.5I
SILTY GRAVEL W/TRACE SAND (GM)
Few Cobbles
Brown, Slightly Moist, Very
Dense
6.5'
LOCATION SKETCH No Scole
T.H.-1
172nd Street
SANDY GRAVEL W/TRACE TO
SOME SILT (GP-GM)
Brown, Dry, Dense
18~T.D.
No Water Table Encountered.
NOTE; DISTANCES SHOWN ARE APPROXIMATE A~D HAVE
NOT BEEN MEASURED 8Y SURVEYING METHODS.
EXPLANATION
ORGANIC MATERIAL
Little Vis~ble Ice 0:10' Vx
I~'Ss, ?'2, 57. I°/o, 85.9 pcf
~-~P~OX. STt~ATA CHANG~
BEDROCK
G~OU, V~ ~
TYPICAL SOILS LOG ~.B-AFT£R BO/~ING
SAMPLER TYPE SYMBOLS
.see abo~,L' SOILS LOG /J
LOT 11, BLOCK 3
SUSITNA VIEW ESTATES
ANCHORAGE, ALASKA
PROJ. N0851130 ~
TIME
ELAPSED
TIME
TABLE I
PERCOLATION TEST
Jim Arnesen
R & M NO. 851130
FEET
DROP IN INCHES
10:30
10:31
10:32
10:33
10:34
10:35
10:36
10:37
10:38
10:39
10:40
10:45
10:50
10:55
11:00
11:20
11:30
1
2
3
4
5
6
7
8
9
10
15
2O
25
3O
5O
6O
2.0'
2.0'
2.0'
2.0'
2.05'
2.05'
2.05'
2.05'
2.1'
2.1'
2.15'
2.2'
2.25
2°30'
2.31'
2.5'
2.55'
0
0
0
0
0.6
0
0
0
0.6
0
0.6
0.6
0.6
0.6
0.6
1.2
0.6
6.6 Inches Total Drop
9.1 Minutes Per Inch
February 2, 19f~2
Lot 7 - Sus£tna ~lew Estates
To Yrnom ~t May Concern~
Lot 7 of the Susitna Vi(~w Estates must have a 100 foot pro-
tectod creek s~'L-bac5~ on both sides of the creek and no sep-
tic tank or drainfie!d c~n encroach into ~l~is protected
area. Also, '~he On-site investigation shows slopes 5[reater
%hah 25%°
A proposed developer ~nust havre lO,O00 ~c!uare feet less than
25% as to install an on-site s~ptic, system.
Sincerely,
John W. Lynn
I~nviromnC~ntal
L~_,./ MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVII~N~'ff~I~I~,~.~(~'rAIGO~.N
CERTIFICATE OF INSPECTION FOR HEALTH AUTH~I~VAL
o. s.w..
264-4720 '
GENERAL INFORMATION L~
(a) Legal~o~Description,~ ,include~lo,, block,~ subdivision,~_~section, to~nship,~ range)~~
Location (address or directions)
(b) Applicant Name :~:~ ~/~ Telephone:Home ~:-~// Bu~ine~8
Applicant Address
(c) Applicant is (check one): Lending lnstitution~ Owner/builder ~; Buyer ~; Other ~ (explain);
(d) Lending Institution Telephone
Address
(e} Real Estate Company and Agent ,
Address
Telephone
(f) Mail the HAA to the following address:
TYPE OF RESIDENCE
Single-Fami[y~ Multi-Family []
Number of Bedrooms
Other
WATER SUPPLY
Individual Well,,~ Community [] Public []
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite/~ Public [] Community [] Holding Tank []
Note: If corn m unity well system, must have written confirmation fro m the State Department of Environ mental Conservation
attesting to the legality and status,
Page 1 of 2 72-025 (11/84)
ENGINEERING FIRM PROVtDIN~-G'~INSPECTIONS, TEST~i FILE SEARCH, DA~A AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage flies and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection. ~. - ..
Engineer's Seal
Approved for --/-'¢/~" bedrooms by .. .
Approved ~/~ Disapprovec~
Terms of Conditional Approval
Conditional
Date
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending'
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct in.¢ ~ections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 {11/84)
MUNICIPALITY OF ANCHORAGE (MO~"Y
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
264-4720
Legal Descri~~
WELL DATA
Well Classification __~ IiA, B, C, D.E.C. Approved (Y/N)
Well Log Present (Y/N) ~-,-~ Date Completed ~ Yield
Total Depth I"~""' Cased tO ,J'~' Depth of Grouting
Static Water Level ,~3 I Pump Set At
Casing Height Above Ground ~ _~,'. ~. Sanitary Seal on Casing (Y/N)
Electrical Wiring in Conduit (Y/N)~-- Depression Around Wellhead (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot } CO ! "~ ; On Adjoining Lots
To Nearest Edge of Absorption Field on Lot l'~)l'~" ; On Adjoining Lots
To Nearest Public Sewer Line ~/..~O/t~'~-~ To Nearest Public Sewer
Cleanout/Manhole ~,,/~2/'¢2~,¢¢'¢ To Nearest sewer Service Line on
Water Sample Collected by ~ _~,o _~___~,- ~ ~'"~"'~4~'~¢~ ~'~ ;Date
Water Sample Test Results I . . ~.,..~,_
Comments ~_~ ~;,'~ ;~ ~-.,~..,'
B. SEPTIC/HOLDING TANK DATA
Date Installed ~ Size I ~..~"'~ No. of Compartments
Standpipes (Y/N) %~ Air-tight Caps (Y/N) ~::r.~ Foundation Cleanout (Y/N) . ;~
Depression over Tank (Y/N)/~4:~ Date Last Pumped
Pumping/Maintenance Contract on File (Y/N) ~,~ ; for
Holding Tank High-Water Alarm (Y/N) ~'//.~. /' - - -
. Temporary Holding Tank Permit (Y/N)
Separation Distances from Septic/Holding Tank:
TO Water-Supply Well
TO Property Line
To Water Main/Service Line
To Building Foundation
To Disposal Field
To Stream, Pond, Lake, or Major Drainage
Course
Comments
Page I of 2
72-026(11/84)
ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Width ct Field t
Gravel Bed Thickness
Square Feet of Absorption Area
Depression over Field (Y/N)
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well //~)O /'"~
To Building Foundation 7~/:~/'¢'
Lot ./~/¢/b/~C '
To Water Main/Service Line __ / ~' O / '-~
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area .
To Property Line
To Existing or Abandoned System on
; On Adjoining Lots / ~4:> I~ '~'
To Cutbank (if present)
Comments
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Comments
Dimensions
Manhole/Access (Y/N)
"Pump Off" L ~/el-'~
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I havc,ch.~ck~erifi/e~l, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
S i g n~ _~/~-~ -,'"~./¢" .. Date
Company ~~ ~¢- MOA No.
R ei iNo.
Date of Payment /~
Amount: $ ~ ~ ~1%'"" ~ '"? ' ¢' Engineer's Seal
-
~ W. Benson Blvd.
Suite ~
PENINSULA ENGINEERING
Anchorage, Alaska 99503
(907) ~61-~107
December 30, 1985
Mr. Curtis Elton
17115 Feodosia Drive
Anchorage, Alaska
RE: Lot 11 Block 3 Susitna View Est.
Adequacy Test of Septic System
Dear Mr. Elton:
At your request we have performed an adequacy test on the above
referenced septic system. The test was performed by adding 600
gallons of water to the absorption trench and monitoring the results
for two consecutive days. Water was added at 7 gpm from the well on
both days, which served as a good test of the well delivery.
The system functioned adequately for a 4 bedroom capacity and the well
delivery was good. A tabulation of the test results follows.
Date Time Tank Trench Quantity
12/17 0 18" 52" 0
20 18.5 60 140
60 19 70 420
85 19 74 600
12/28 0 24 53 0
30 24 66 210
50 24 71 350
85 244 75 600
12/29 0 30 53 0
If I can be of any further assistance please call.
Sincerely,
Wayne He~erson, P.E.
WH:js
PENINSULA ENGINEERING
CONSULTING ENGINEERS
TO: Date:
440 WEST BENSON BLVD., SUITE 206
ANCHORAGE, ALASKA 99503
PHONE: (907) 561-5107
Re: Engineering
Other []
Project No.:
LEGAL DESCRIPTION:
SERVICES:
Total $ -' ~-' ~' ~
All accounts are due upon receipt of services by PENINSULA ENGINEERING. Credit accounts not paid
within thirty (30) days following receipt of service will be charged 2% per month on the unpaid balance,
I hereby acknowledge receipt of
the payment terms stated above,
PLEASE PAY PROMPTLY
copies of the above described Report and understand
Signed Date
-~ INSPECTION APPOINTMENTS
TIME TIME TIME
DATE
OATE DATE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
825 L Street - Anchorage, Alaska 99501
( ENVIRONMENTAL SANITATION DIVISION
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND sEWER FACILITIES
DIRECTIONS: Complete all parts on paue 1. Incomplete reques~ will not be proceed. Please allow ten (10) days for processino.
PHONE
1. PROPER YOWNER
MAILING ADDRESS
PROPERTY R~IDENT (If different from above)
PHONE
2, BUYER
MAILING ADDRESS
] PHONE
MAILING ADDRESS
I PHONE
4. REALTOR/AGENT
A,U.e AOO SS
5. LEGAL DESCRIPTION
i..O'P !1 .<7 r' nc
:TR EET LOCATION
NUMBER OE~OEOROOMS
TYPE OF RESIDENCE [] One [] Four
~.__ SINGLE FAMILY [] Two [] Five
[] MULTIPLE FAMILY ~... Three [] Six
[] Other
WATER SUPPLY [~ INDIVIDUAL*
[] COMMUNITY
[] PUBLIC UTI LITY
* ATTACH WELL LOG. A well log is required for all wells drilled
since June 1975, For wells drilled prior to that date, give well
depth (attach log if available.)
8, SEWAGE DISPOSAL SYSTEM
'-~.!NDIVIDUAL/ON-SITE** [ ~/~ YEAR ON-SITE SYSTEM WAS INSTALLED.
[] PUBLIC UTILITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED,
72-010 (Rev, 6/79) I ~
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE
,,... SI NG L E FAMILY
[] MULTIPLE FAMILY
2. WATER SUPPLY
~.' INDIVIDUAL
[] COMMUNITY
[] PUBLIC UTI LITY
Connectio9 Verified
3. SEWAGE DISPOSAL SYSTEM
[] INDIVIDUAL/ON -SITE
[]PUBLIC UTILITY
Connection Verified
[]Septic Tank or []Holding Tank
~l~¢_C~f' Tank is homemade
Size:
give dimensions:
TYPE OF TANK
TOTAL ABSORPTION AREA
4. DISTANCES
WELL TO:
Absorption Area to nearest Lot Line
NUMBEROFBEDROOMS
[] ONE [~-~. TH R EE [] FIVE
[] TWO [] FOUR [] SIX
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
~/'~
PERMIT NUMBER
DATEINSTALLED
INSTALLER
Line
[] OTHER
SOILS RATING
MANUFACTURER
Nearest Lot Line
5. COMMENTS
EJ~J-'~APPROV ED FOR _~ BEDROOMS
CONDITIONAL APPROVAL (letter must ac
DISAPPROVED
DATE
Lany certificate)
72-010 (Rev. 6/79)
GREATER ~2-~CHORAGE AREA BOROOGI~
104 West l~orthern Lights Boulevard
Anchorage~ Alaska 99503
S- 19S'6
Plat Status: Final
Date~ June 17, 1970
BOROUGH: Engineer /
Health Department
Public Works Department
Sand Lake Fire Department
.School District
Street Names
Tax Assessor
Alaska Department of Highways
Alaska Railroad
Anchorage Natural Gas COrpo
Central Alaska Utilities
Chugach Electric Association
CITY OF ~J]~iOP~,GE: Fire ilarshal
}~nnicipal Light & Power Department
Property Management Officer
Public Works Department
Telephone Utility
Traffic Engineer
Water Utility
GAB Teleconmmnications~ Inc.
Matanuska Electric Association
Matanuska Telephone Association
Assistant Superintendent of Mails
Re: Subdivision / ~I~C~I~lY~
Description of Property:
Se~ attached plat
Bob Pennington
Gentlemen:
Petition has been received by the Greater Anchorage Area Borough Planning
and Zoning Commission for the proposed Subd. of subject property.'
Attached is a copy of ~e proposed plat. Wi. 1 you please submit your
comments in writing~ specifying any easements or other requirements that
your department or agency may need.
If we do not hear from you by Jul~..~., 19~0
you do not wish to submit any comments.
· we will assume that
If you have no further use for the attached print, please return it with
your comments.
Planning Department