ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP211189 PID Number: 051-172-35
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ® Upgrade
Name
EDNA MEYER
ABSORPTION FIELD - EXISTING
❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
18839 S BIRCHWOOD LOOP RD., CHUGIAK
❑ Other
Phone
Number of Bedrooms
Soil Rating
depth from original grade
3
GPD/SF
JTotal
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
125
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
T1 5N R1 W 18
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ft2
Ft.
well.1"00'+
=
25'+
TANK ® Septic uS.T.E.P. ❑ Holding E Other
Manufacturer
GREER
Capacity
1000 Gal.
Surface water
100'+
--
Material
HDPE
Number of compartments
2
Lot Line
5'+
-_
NA
Foundation
10'+
--
LIFT STATION
Manufacturer
Capacity
Gal.
Remarks Tank insulated.
Alarm location
Electrical installed by
Installer JRS
PIPE MATERIAL House to tank 3034 Tank to 3034
drainfield
Drainfield CO/MT 3034.
Inspector FWCS
BENCH MARK (Assumed elevation) 100 ft
Inspection ection 1st7/7/2021 7/7/21
Location and description
2�d
3`d 10/25/21 4`h
PIER BLOCK — 3RD OUT FROM STAIRS TO DECK
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
4 1k�
Conditional Approval: Date
.� l■
AdwAw
Ave
�
*: 49 7H .Septic ....•:*
� �.. Curtis Huffman• • : * j
�0 F • CE 128991
dstem
Approve
Date a0/0&_a
�tlslF�• 1/12/202�.•��v`�,�
lF�
1iPROFESVO .�
Note: this approval does not include well permit requirements.
\
kRvv UUIU4110)
PID: 051-172-35 PERMIT: OSP211189
A—C=48.0'
B—C=45.7'
A—D=52,4'
B—D=49.0'
A—E=61.5'
B—E=56.0'
J
J
WELL
LOT 125
DECOMMISSIONED EXISTING
S.T. & INSTALLED NEW
1000 -GAL HDPE SEPTIC TANK.
STAKED AT CONST.
N89054"34"W 515.90'
SEPTIC SECTION
SCALE, NTS
T1 5N R1 W SEC 18 LOT 125
PREPARED FOR:
EDNA MEYER
18839 SOUTH BIRCHWOOD LOOP
CHUGIAK, AK 99567
FIRST WATER CONSULTING
13030 SUES WAY
ANCHORAGE, AK 99516
907-350-9566 FirstWaterAKCa@gmoil.com
SUPPORT SERVICES:
9TH
c * TH
DATE: 1/12/2022 rtis Huffman
SURVEY: JLS CE 128991
DRAWN: FWCS 1 /12/2022
SCALE: 1" = 30' ssioN�'
*,o 8-
83
0 Y.
G)
71
cn
U)
12 CD
R
Z z
(n.. Ln
cn q
T Z3 8
c 5� �l -
2tcs
CD 0
t
¢ r
ul E7x
co 0
Cl>
� C HULZ
07
7/
LOT 101 B
N89'54'34"W
(N90'00'00"W
m
!13
C)
z
> —4
z
-4
i*
it
515.90'
�N90'00'00"W 520.78' R)
ROX90M
m
163.6'
O
012
7/
LOT 101 B
N89'54'34"W
(N90'00'00"W
m
!13
C)
z
> —4
z
-4
i*
it
515.90'
�N90'00'00"W 520.78' R)
ROX90M
m
163.6'
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (9 07) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP211189
Work Type: SepticTank Upgrade
Tax Code Number: 05117235000
Site Legal Address: T15N R1 W SEC 18 LT 125 G:1155
Site Mailing Address: 18839 S BIRCHWOOD LOOP RD, Chugiak
Owner: MEYER EDNA M
Design Engineer: FIRST WATER CONSULTING
This permit is for the construction of:
Effective Date:
Expiration Date
Lot Size in Sq Ft:
Total Bedrooms:
t
U
Department
6/7/2021
6/7/2022
74923
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: Date:
Issued By: Date: Z y
3
Development Services Department
On -Site Water & Wastewater Section
Parcel I.D. 051-172-35
0.(.
Phone: 907-343-7904
-- Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Property owner(s) EDNA MEYER Day phone
Mailing address 18839 S BIRCHWOOD LOOP ROAD, CHUGIAK, AK 99567
Site address 18839 S BIRCHWOOD LOOP ROAD, CHUGIAK, AK 99567
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section)
T1 5N R1 W SEC 18 LOT 125
Lot Size 74,923 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) 0
(w/wo ADU)
Septic Tank
0
Upgrade 0
Duplex
F-1Holding
(D)
Tank
ElRenewal
ElMultiple
Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES
A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: v�� 5 Waiver Fees:
Date of Payment: 6��Z
Receipt Number: —//Z01 I.
Permit No. O S r'?, 111 $ `j
Date of Payment:
Receipt Number:
Waiver No.
GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
June 29, 2020
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC TANK UPGRADE PERMIT
LEGAL: T15N R1W SEC 18 LOT 125 18839 S BIRCHWOOD LOOP
The owner has requested that we obtain a septic permit to upgrade the existing aged steel septic
tank on the above referenced lot. We propose to install a 1000-gallon HDPE tank per the
attached design to serve the existing 3-bedroom residence. The lot and area are served by private
wells. The design will not impact any of the neighboring properties. Please contact us if you
have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211189, Deb Wockenfuss, 06/07/21
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP211189, Deb Wockenfuss, 06/07/21
Municipality of Anchorage Page 1 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW000122 PIDNumber: 051-172-35
N~me: Wastewater System: [] New ~ Upgrade
Edna Meyer -
Address'
1 8839 Birchwood Loop Chugiak, AK ABSORPTION FIEED
Three ( 3 ) [] DeepTrench ~[Shallow Trench [] Bed E] Mound [] Other
LEGAL DESCRIPTION Sol, Rating: . 6 GPD/Sq. Ft. IOta[ Depth from5orlgir, algrade:
Lot: Block; Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath
Lo
t
1
25
2.5 Ft. 2 Ft.
~/[1L: [] blew [] Upgrade ~ .5 Ft. 2~
Existing' Ft. Ft.! 814 SO. Pt ASTM D3034 PVC
Ft. DCrr Excavatino
Yield: . Casing Height Above Ground:; ·
SEPARATION DISTANCES :~ Septic [] Holding [] S.T_E.P.
From Tsnk Field Station Tank SewerLines Anchorage Tank 1,000
Well- > 100 ' > 100 N/A N/A >25 ! Matedah . Number of Compsrtments:
Steel Two .
suCaoe >100' >100' N/A N/A N/A LIFT STATION - N/A
Water
Lot >5 ' > 10 ' N/A N/A N/A Size in gallons: Manufacturer: '
Line
>5' >10' N/A N/A N/A "Pump on" ,eve, at: J-pump ofr',evelat~, j High water alarm at:
Foundation
I
BENCH
Remarks: · Exis[inq Septic Tank Pumped
· ' Location and Descdptlon: Garage Slab
Crushed and Back£illed On Site. -
2" Insulation .Over Tank an(~
Absorption. . Trenches'. 'I - 107,6 ~1.
. ' .' . '~"~ .,~ ~,~ ~
, F~.,~'ns"~'~ns~- ~"e~orme~wk": SEA Dates: 1St 6 / 1 2 / 0 0' * '~?'~ .
Depadment of Health and Human Se~ices approval }~%~',. ~¢¢:;%4~
~C)
'
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 - Anchorage, AK 995'19-6650 - 343-4744
On-Site Wastewater Disposal System or Well Inspection Report
Page 3 of 3
Permit Number SW000122
PID No. 051-172-35
102.0
¸38'
105.2m
,-7--
1,000 Gi
sep. Tar
105.0
\ 102.1 /
6'I 11'5' / 36'
2" Insulation
Drain Field Rock
92.0
51'
100
6'
I
02.0
0
. Drain Fi'eld Rock
52'
92'.0
PROFILE .AS-BUILT
1" =10'
MUNICIPALITY OF ANCHORAGE
Department cf Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: May 24, 2000
Expiration Date: May 24, 200t
Permit Number: SW000122
Legal Description: T15N R1W SEC 18 LT 125
Design Engineer: 0014 Anderson Engineering
Owner Name: Edna Meyer
Owner Address: 18839 Birchwood Loop Road
Chugiak, AK 99587-
Parcel ID: 051-172-35
Site Address: 018839 BIRCHWOOD LOOP RD
Lot Size: 74923 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
TOTAL DEPTH OF THE PROPOSED ABSORBTION TRENCH AT ANY PORTION OF THE FIELD SHALL NOT
EXCEED 6 FEET FROM ORIGINAL GRADE~
Date:
Date:
April 27, 2000
Municipality of Anchorage
Department of-Health and Human Services
825 "L" Street
Anchorage, AK 99502-0650
Subject:
BLM Lot 125, Section 18, 'F15N, R1W
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Englr~eer:
The existing septic system on BLM Lot 125, Section 18, T15N, R1W has failed and
must be upgraded. We are therefore applying for a permit place a new septic tank and
absorption system on the lot to serve the existing three bedroom home; The attached
Site Plan and backup documentation show the location anG configuration of the new
septic syStem and the loCation of the existing well and septic system. The 100'
protective radius for the well and neighboring wells is also shown on the Site Plan
Two testholes were placed on the lot to find an acceptable location for the upgrade.
Both holes revealed sandy silt material which percolated between 20 and 30 minutes
per inch. Groundwater was noted during excavation at approximately 12' below the
surface. The level rose to between 11' and 11.5' period which is probably the high
water period for the year. We have therefore designed a 5' wide shallow absorption
trench with 2'of gravel beneath the distribution line. The tota depth of.the trench will
be 7' below existing ground. Two trenches a total of 110' in length will be constructed.
Each trench will be 55' long and a Zabel fl0w splitter valve will be placed to assure even
distribution of effluent to each trench.
The lot surface is basically flat with shallow slopes from southeast to northwest at 0% to
a maximum of 1%. The existing septic.tank and absorption crib wil be oumped.
crushed, backfilled and abandoned in place. The existing tank is currently within the
100' protective radius of the well and the crib is just outside the radius. The new
system will be constructed-entirely outside the protective radius. Placement of the new
system in the location shown will have no effect on wells or septic systems on adjacent
lots.
If the system is constructed in accordance with our design the following statements
apply:
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse ~mpact on existing
BLIVl Lot '125, Section '18, T15N, R1W
April 27, 2000
Page Two
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserved
space, either surface or subsurface, on any ets located in the area
The system, if constructed as designed, witl have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson P.E.
Attachments
~, o%
4Jq~
c~4J
0~)
0
BLM- LOT 125, SECTION 18, T15N, RIW
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Three Bedroom Home
Perc. Rate: 20 Min./Inch
Application Rate: .6 GPD/SF
5' Wide Trench System
1,000 Gallon Septic Tank
2' Drainfield Rock
Bedrooms X 150 GPD / .6 GPD/SF = 750 SF of Absorption Area
750 SF/5 LF (Width) X .7 (Red. Factor) = 105 LF Trench Length
Therefore: Construct Two 5' Wide By 55' Long Absorption Trenches As
Shown on the Site Plan with 2' of Drainfield Rock Beneath the Laterals.
Distribution Pipe in Trenches Placed at 5.0' Below Original Ground
Surface. A Zabel Flow Splitter Valve Shall be Placed to Evenly Distribute
Flow to Each Trench.
Natural
Backfill
4.5'
.SI
2.0'
.Geotextile Fabric
4" PVC (Holes Down)
Drainfield Rock
NOTE:
TYPICAL WIDE TRENCH SECTION
(NO SCALE)
Grade Area Over Trench to Drain Away.
Minimum 10' Separation Between Trench Sidew~all~.,,
Minimum 10' Separation From Lot Line.
Minimum 4' Separation From Groundwater.
Municipality of Anchorage
Department of Health & Human Services
825 L Street, Anchorage, AK 99502-0650
SOILS LOG - PERCOLATION TEST
Performed For: Edna Meyer
Legal Description: BLM Lot 125. Section 18. T15N. R1W
OG/OL
SM
Gravel
;LOPE
North
South
Date Performed: '~
SITE PLAN
See Site Plan
Was Groundwater
Encountered?
if Yes, What Depth?
1, Depth to Water,
After Monitoring
11 Date:
Yes S
12' L
O
11' P
4/28/00 E
0%
12
13
14
15
16
17
18
Bottom of
Hole
Reading Date Gross Net Depth To Net
Time Time Water Drop
1 4/24/00 10:00 4.375"
2 10:30 30 5.875 1.5"
3 11:00 30 7.375" 1.5"
4 11:30 30 8.875" 1.5"
21
Perc. Rate: 20 Min./Inch Perc. Hole Diameter: 8"
Test Run Between 5 Ft. and 6 Ft.
Comments: Testhole Presoaked Prior to Percolation Test. Design System for 30 Min./Inch.
Performed By: Tim Kimbrough. I, Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 4/28/00
Municipality of Anchorage
Department of Health & Human Services
825 L Street, Anchorage, AK 99502-0650
SOILS LOG - PERCOLATION TEST
Performed For: Edna Meyer
Legal Description: BLM Lot 125. Section 18: T15N. R1W
OG/OL
SM
~ome Gr:a(,el
TESTHOLE NO. 2
SLOPE
North
South
Yes
12'
Date Performed:
SITE PLAN
See Site Plan
1
11
Was Groundwater
Encountered?
If Yes, What Depth?
Depth to Water
After Monitoring
Date:
11.5'
4/28/00
O%
12
13
14
15
16
17
18
Bottom of
Hole
Reading Date JGross Net Depth To Net
,Time Time Water Drop
1 4/24/00 11:15 3.25"
2 11:45 30 4.75" 1.5"
3 12:15 30 5.25" 1.5"
4 12:45 30 6.75" 1.5"
21
Perc. Rate: 20 Min./inch Perc. Hole Diameter: 8"
Test Run Between 5 Ft. and 6 Ft.
Comments: Testhole Presoaked Prior to Percolation Test.
Performed By: Tim Kimbrough. I, Michael E. Anderson Certify That This Test Was Performed
In Accordance With AIl State and Municipal Guidelines In Effect On This Date: 4/28/00
G""A. TER ANCHORAGE AREA BORO~'~H
HEALTH DEPARTMENT
327 EA~LE ST. ANCHORAGE, ALASKA 99501 279-251
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCATION
SEPTIC TANK:
ADDRESS ~/,~./~P H O N E
/
DISTANCE FROM WELL
LIQUID CAPACITY
MATERIAL
GALLONS. INSIDE LENGTH.
NUMBER OF
COMPARTMENTS /
(.~/.~ F/"~'~' 7~'~ LIQUID
.INSIDE WIDTH DEPTH
SEEPAGE SYSTEM:
NUMBER OF PITS
LINING MATERIAL
NEAREST LOT LINE
SEEPAGE PIT:
OUTSIDE DIAMETER
OR WIDTH /~/ --
DISTANCE FROM WELL /~ ~"'~!
TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA)
! LENGTH~''~'~ f- '~f"/ DEPTH
BUILDING FOUNDATION
TILE DRAIN FIELD:
DISTANCE FROM WELL
NUMBER OF LI ~S~/
ABSORPTION AREA
-- FOUNDATION ., N E A~g TJ C) ~.,~,.,.~
DISTAl-; L;;-;~TRENCH WIDTH
TOTAL LENGTH
., OF LINES
IN. TOTAL EFFECTIVE
SQ. FT. LENGTH OF EACH LINE
DEPTH: TOP OF TILE TO FINISH GRADE
DEPTH OF FILTER MATERIAL BENEATH TIL~
ABOVE TILE
WELL: T Y p E~'~,~-'''~' z ~-~ DEPTH ~..~-'~'~ !
NEAREST SEPTIC
LOT LINE L/ .. SEWER LINE ~'~ ,TANK
DISTANCE FROM WATER
· BUILDING FOUNDATION. '~ / SAMPLE . NEAREST
~G r SEEPAGE / OTHER
· , SYSTEM ~C~"~ , CESSPOOL ~ , SOURCES__
DISTANCES:
DIAGRAM OF SYSTEM
/
DATE
GREATEI
327 Eagle St.
s~NCHORAGE AREA ' 3ROUGH
HEALTH DEPARTMENT
Anchorage, Alaska 99501 279-2511
Case N o .~Z/-,.¢--~
SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT
APPLCAXIONTO INSTALL: SEPTIC TANK ~' ,SEEPAGEPIT~,DRAIN FIELD ,OTHER
TO SERVE THE FOLLOWING FACILITY
FIN/~NCED THROUGH
.4ar~E~ti~-T EST RESULTS
BELOW TO.BE FILLED OUT BY HEALTH DEPARTMENT
THIS IS TO SERVE AS '- "~',~d~-/~C , PERMIT TO INSTALL A /"-z~7'~// ,
ASDESCRIBEB BELOW. SIZE O~ UNITT0 BESERVEB , ~ ~.- '; ~*'h,
Il! - .~ /: .~-a t.~ .
..~,,~,A,~,~ TS¥ ,,~~~,A~A"~A~7 '"~ ~'
DIAGRAM OF S~TEM
LICENSED DESIGNER "~O ['
I certify that I am familiar with the requirements of Greater Anchorage Area Borough/Ordinance No, 28-68 and that the
above described system is in accordance with said code, '/~' ~'£///.'~ ~/,¢,J/d"~"7-- ~/~' 7~ ~
l ' '
TO BE INSTALLED BY/~'/~{-,~/,-~:) dOd~5~///r~'/'~,~-'
ANTiCiPATE0 DATE OF C0MPLET~0N oO¢//~_.. /~,¢?'ZCW
GREATER ANCHORAGE AREA BOROUGH
HEALTH DEPARTMENT
397 EAGLE STREET
ANCHORAGE, ALASKA 99501
CASE #
Performed For I~.~L Kne¼1,,- ...... ~_~_.~.~_Date Performed~m,~
Legal Description: Lo.t,.l~Block . Subd~vzszon.~o~. ID %~J~ .1~.~ .
This Form Reports a: Soils 5og__.__~ .~ ; .Percdlation Test__
Depth
Feet
I I--~
Was Ground Water Encountered?~
If Yes, At What Depth..._..
Location Sketch
M
Reading Date Gross Time Net T~me Depth To H20 Net D~op
' [6"~"/ "'
~Poola~on a~ ~nn~ ~- .... ---~--
Proposed Instal~Seepa~e Pit l.---' [)rain Fi. eld
D~pth Of ]nlet ~', , Dep~ To Bottom O~ Pit Or
CO~E~TS: . .A'~ ~.~ ~ ~'/~ , , - -- " -
Test PerformedB
Data Certified By:._~
Date :..~_._~ .7/~---') 9 ?-/I- -- '
GREATER ANCHORAGE AREA BOROUGH }/~/--~(~ ]
~/~~R~~~--m/~/)a-~/~- '.~] Date Received OCtober 28, 1976
~~~ ~'~/~ TDime ~fi Inspe~
~ ~. ate o nspection ~
INDIVIDUAL SEWERF~RWATER FACILITIES ' ~
Conv.
1. Approval requested by: Alaska Bank of Co~erce % Susan Jansen
Mailing Address: 712 West 4th Avenue Phone: 279-5641 x 341
2. Property Owner:
Mailing Address:
3. Legal Description:
Jack C. Stevens Phone: 688-3148
Star Route Box 677 Chugiak
T15N R1W Section 18 Lot 125
South Birchwood Loop Road
4, Location:
Type of facility to be inspected
Well Data:
A. Type Individual
C. Construction
D. Seepage Pit:
E. Disposal Field:
Single Family No. of bedrooms
B. Depth 165'
D. Bacterial Analysis
Sewage Disposal System: on-site system
A. Installed ju~FT~'~'/~ B. Installer
C. Septic Tank: 1. Size /~/o 2. Manufacturer ~/
./
1. AbsorptioffArea~ 2. Material
Total length of lines
Distances:
A. Well to: Septic tank
2
B. Foundation to septic tank , Absorption area
C. Absorption area to nearest lot line
LQ-034 (1/74)
Nearest lot line
, Other contamination
Page 1 of two pages
[
, Absorption area /~-~ / , Sewer Lines
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
2510 East Tudor Road, Anchorage, Alaska 99504 276-2221
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
Type of Inspection: CMRO VA FHA_
Property Owner: ~'-~¢-~¥~ ~' , ~ ~ ~ ~) ~-~
Mailing Address: ~%~ k'~, ¢~.o-~ L, qq ! ~,,o,,~ Day Phone:
3. Name of Buyer:'~'c~'°~ \~.,
Mailing Address: ~oL.~L5- L.~ , q-~o-t~' ,~C' '~', Day Phone:
4. Name of Lending Institution: .~.~.~.
Mailing Address: ql~, ~,~'
5. Name of Realtor or Agent: (~_~¥e&% ~-
Mailing Address: r~,~. ~b,z.
6. Legal Description: ~-~-~- ~.~,
CONy?'~
Phone:
7. Type of Facility to be Inspected: ~\~ Ig -~,~',1,, (~'-S, ~'~'eNo. Bdrms.
- ~
8. Water Supply
Type of Supply: Public Utility. Individual
If Individual, number of dwellings presently served
/
If Individual, depth of well ] (~'~
Sewage Disposal System
Type of System: Public Utility
If Individual, date of installation
Individual (on-site)
72-003(3/76)
Page 2 of two pages - Re¢ st for Approval of Individual F ~r & Water Facilities
Legal Description T15N R1W Section 18 Lot 125
Comments
Approved
Approval Valid for one year from date signed
Greater Anchorage Area Borough, Department of £nvironmenta] Quality
DIAGRAM OF SYSTEM
certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED
Date
EQ,034 (1/74)
GREATER ANCHORAGE AREA BOROU6H
Department of Environmental Quality
3500 Tudor Road, Anchorage, Alaska 99507 279-8686
Date Received OCt 11, 1973
Time of Inspection ll:O0 a.m.
Date of Inspection
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER & WATER FACILITIES
FOR
VA
1, Aoproval Requested By: Smileys Realty
Address: BOX 1086 Eagle Riyer
2. Property Owner: Vance~ Nolder
3. Legal Description: Lot 125, Sec 18~ T15N~ R1W, SM
4. Location: Birchwood Loop Road
5. Type of Facility to be Inspected: Single
Number of Bedrooms:
Well Data:
A. Type Dri]]e~
c. Construction
7. Sewage Disposal System:
A. Installed 1970
C. Septic Tank: 1.
D. Seepage Pit: 1.
D}sposal Field:
8, Distances:
B. Depth
D. Bacterial Analysis
8. Installer
.Size 750 Gals 2. Manufacturer Steel
Size 2. Material Log Crib
Total Length of Lines
Well. To: Septic Tank 66'
, Nearest Lot Line
Foundation to Septic Tank
Oct 12, 1972
A. , Absorption Area 100'
, Other Contamination
B, '~ Absorption Area
C. Absorption Area to Nearest Lot Line
Phone: §94-2115
Phones
Sewer Lines
~eq,]e£t loT. Approval of Inoividual Sawer & Water Facilities
Pa~e
Comments:
.A~pro ~ Disapproved Date__
/ / Approval Valid for One Year From Date Signed
~eater Anchorage Area Borough, DeF~rtment of Environmental Quality
DIAGRAM OF SYSTEM
I cer%if%~ that the information contained in this request for approval to be a true
and accurate representation of the subject sewer and water facilities located at:
Signed Date
REQUEST FOR APPROVAL OF
INDIVIDUA.L SEWAGE AND WATE. R FACILITIES/
(F~ll out in T~iplleate)
'~_ ~a~ .of person requesting approval
a. Bac~cerial ..... .
b. Detergent
Well data:
b. Depth. .~//~-/.. .
c. Casing Size
Distance from well to closest existing or proposed:
1. Sewer line
Septic .
3, Seepage Area /Z~ / .
4. Cesspool~ .... .
5. Property Line. .
6. Other sources of possible contamination, i.e., creeks, lakes,
houses, barn, drainage ditch, etc.. .............. .
Sewa.ge disposal system.
a. Age of system, /'~7~J~.
b. Septic tank capacity in gallons ~j~ ..
1. If "home made" show diagram on reverse side of this form.
Disposal field or seepage pit size and type
Distance to property..line _~ ~ tO house foundation~. '
f. Percolation Test performed by
Use the reverse .side of this form to show diagram. Diag~a~ should include
...The following lnfo~mation: p~ope~ty lines,.well location, house location,
~pTic tank location, disposal area location, location of pemcolat~on tes~,
a~. direction of ground slope.
9. The ~f-o~ma~ion on this form is tmue and co~ect to the best of my knowledge,
'§[~6arure Of Applicant
Date S~gne
Tq BE FILLE,D OUT BY HE.~LTH DEPAETMENT P~SON~E~L
he above described ~anitamy facilities are hereby approved, .subject to the
Conditions
The above described sanitary facilities are disepproved rom the following
~easons: ....
'-Ap 1 ~s valid for one yea~ _ __ _ ~fo]]owln~ the date of
..-~ CPJ:cw
September 2, 1970
P.O. Box ~80
Anchorage, Alaksa 99501
SUBJECT:
Sewer and Water Systems for
Lot 125, Section 18, T15N,
RiW, S.M.
Dear Sire:
Sewer for the subject lot consists of a 750 gallon septic tank and
a seepage pit with a total effective absorption area of 468 square
feet. The sewer sgstem was inspected and approved on June 2~, 1970.
Water iaS~upplied hy a drilled well 65 feet deep, and a water
sample fr~the well was satisfactory. The well casing extends
above ground hut there is a pit .around the well. The pit must he
filled in and the pressure tankiin the pit placed underneath the
house. This would he a relatively simple operation.
Sincerely yours,
CLIFFORD P. JUDKINS, R.S.
Administrative Director
JRL/cm
By
John R. Lee, R.S.
Sanitarian