ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: S~,~C[~ [~ ~-[~ PID Number
Wastewater System: ~New ~ Upgrade
Address: rD550 ~ ~t~ ' ~C~OC~ ABSORPTION FIELD
Soil Rating: Total Depth from original grade:
LEGAL DESCRIPTION ~ , ~ GPD/FE I ~ Ft.
BJock Lot: Subdivision: Depth to pipe boEom from original grade: Gravel depth beneath pipe:
Township:~[~ ~ ~Range:~ ~e~Secti°n: ~ Fill added above o iginal~, ~ rade: Ft. Gravel Length~ Ft.
Gravel Width: Number of Lines: Distance be~een lines:
Well: ~ New ~ Upgrade ~ Fb [ Ft.
Classification (Private, A, B, C): Total Depth: Cased to: Total absorp~n ~ P~pe Material:
~eld: ~ Pump Set at: ~ Casing Height Above Ground:
~: Ft. R. TANK
SEPARATION DISTANCES ~ptic ~ Holding ~ S.T,E.P. ~ Other:
To~ Septic Absorption Lift Holding Public/Private Manufacturer: ~ Capaci~:
Tank Field Station Tank SewerLine ~o¢~ ~C. ~ Gal.
I Material: ~ ~ Number of Compa~ments
SuHa~Water ~ G~DI ~ Gb5/ ~ ~ LIFT STATION
Lot Line ~/ [~/ ~/ Size: Gal. Manufacturer:
Foundation ~, ~, ~, "Pump On" level at: "Pump off" level at: I H,gh water alarm at:
Pump Make & Mod~h Electrical Inspections pedormed by:
Cu~ain Drain
Remarks: BENCH MARK
Inspections performed by~ ¢~ Dates: 1st [AJ¢~k~~~J
Dates: 1st J
Department of Health and Human Services approval
Reviewed and approved by: ~ ~ ~ Date: ~-2
72-013 (Rev. 01/00)*
NORTH
PIPE
TEST HOLE
(TRENCH)I
NEW
2,000 GAL.
EXIST. SEEPAGE
& S-BDRM SYSTEM
(PiT ABANDONED
FILLED IN, PIPING
REMOVED) J
TRENCH
(10' x 47')
--TEST HOLE NO.1
NEW
CONST.
EXIST. 2,000-GAL.
CONCRETE TANK
TABLE OF DISTANCES
DISTANCE
FROM/TO (FEET)
NW BLOG CORNER (A) TO TANK CLEANOUT (B) 32.9
NW BLBG CORNER (A) TO ABSORPTION TRENCH CLDANOUT (C) 46.0
NW BLOG CORNER (A) TO MONITOR PIPE (D) 41.7
NW BLOG CORNER (A) TO ABSORPTION TRENCH CLEANOUT (E) 31.2
TANK CLEANOUT (B) TO WELL (F) 116.5
TANK CL~ANOUT (B) TO PROPERTY LINE (APPROXIMATE) 52
ABSORPTION TRENCH C.O. (C) TO PROPERLY' LINE (APPROX.) 15
5%
CONST.
BLM LOT 13
SECTION 15
PACER
PLACE
SHELL
#1S/O
HOUSE
SEPTIC SYSTEM AND RESERVED SITE
BLM LOT 13, SEC. 15, T12N, R3W, S.M.
1 INCH = 50 FEET DRAWN BY PCR
MARCH 2000
NOTE: THIS IS NOT A SURVEYED PLAT.
ALL LOCATIONS SHOWN ARE APPROXIMATE.
Brown Residence
BLM Lot 13, Sec. 15, TI2N, R3W, S.M.
Excavating absorption trench. View looking northeast.
Excavating absorption trench. View looking southeast.
I Test Hole
Soils Log -- Percolation Test
Legal Description:
Date Performed:
Performed For:
BLM LOT 13, SECTION 15, T12N, R3W, S.M.
JUNE 24, 1998
KEVIN A. BROWN
1
2--
3--
4--
5--
6--
7--
8 --
9--
10
11--
16
Perc
Description
Peat/top soil (PT)
Reddish sandy loam (SM
Gray fine silty sand with
some gravel (SM)
Silty sand with gravel an(
organics (SM)
Silty sandy gravel (GM)
Gray silty sand with som{
gravel (SM)
Slope
I I I
-T-F-r-
-
_L_L_I_
I I I
Site Plan
See Separate Site Plan
Test Hole 2
Type:Date Trench 6/24/981 7/1/98
Area: 3ff by 10ft 30sf (Yx 10') * see site plan
Depth: 19 z2
Water Table No water encountered
7th day Mon tot Tube No water present
DeltaT Reading Delta H
Date Reading/Test # Time
(minutes) (inches) (inches)
6/24198 Presoak 7:00 PM
End Presoak 7:30 30 >>>>>> 28
T1 - Add water 7:40 14
7:50 10 6 8
T2 - Add water 7:50 14
8:00 10 6.5 7.5
T3 - Add water 8:00 t4
8:10 10 6.5 7.5
T4 - Add water 8:10 14
8:20 10 6.75 7.25
T5 - Add water 8:20 14
8:30 10 6.75i 7.25
T6 - Add water 8:30 14
8:40 107 7
6/24/98 7- Add water 8:40 1~
8:50 t0 71 7
Percolation Rate (T7) 1.43 MPI
Test Depth between 6 ftand 7ft
Diameter; 4 inch
cedify that this test was performed in accordance with all state and
municiple guidelines in effect on this date. Date:
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Renewal
Date Issued: Sep 17, 1999
Expiration Date: Sep 16, 2000
Permit Number: SW990340
Legal Description: T'i2N R3W SEC 15 LT 13
Design Engineer: 0804 Paul C. Ramert, PE
Owner Name: Kevin A. Brown
Owner Address: 10550 Pacer Place
Anchorage, AK 99516-6330
Parcel ID: 015-112-28
Site Address: 010550 PACER PL
Lot Size: 186040 SQ. FT.
Total Bedrooms: 7 Permit Bedrooms: 7
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions. '
THE SEVEN (7) BEDROOM WASTEWATER SYSTEM SHALL BE COMPOSED OF A MINIMUM OF A 2000
GALLON SEPTIC TANK AND AN ABSORPTION FIELD THAT IS A MAXIMUM OF THIRTEEN (13) FEET DEEP
WITH 10 FEET OF SEWER ROCK BENEATH THE PERFORATED DISTRIBUTION PIPE AND A MINIMUM OF
FORTYFOUR (44) FEET LONG.
Received By:
Issued By:
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Renewal
Date Issued: Sep 17, 1999
Expiration Date: Sep 16, 2000
Permit Number: SW990340
Legal Description: T12N R3W SEC 15 LT 13
Design Engineer: 0804 Paul C. Rained, PE
Owner Name: Kevin A. Brown
Owner Address: 10550 Pacer Place
Anchorage, AK 99516-6330
Parcel ID: 015-112-28
Site Address: 010550 PACER PL
Lot Size: 186040 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapten
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Wet,
3. The engineer must notify DHHS at least 2 hours prior to each insI
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply P
4. From October 15 to April 15, a subsurface soil absorption system
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent fre~
Receiv~~
Date:
Date:
Rick Mystrom.
Ma vor
Mtmicipality of Anchorag¢
Department of Health and Human Services
$25 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
htlp://www.ci.anchorage.ak.us
August 10, 1999
Kevin & Ma~y Brown
10550 PACER PL
ANCHORAGE, AK 995166330
Subject:
T12NR3WSEC 15 LT 13
Permit # SW980371 PID # 01511228
The subject permit #SW980371, issued by this office for a single family well and/or on-site
wastewater system, is due to expire as of 9/18/99.
If this is a well permit and you have drilled the well, a well log must be sent to this office
for documentation of the installation and to close the permit.
If this is an on-site wastewater systm and a licensed Professional Engineer has inspected
the installation, the original as-built inspection report must be sent to this office for review,
approval and documentation. All inspection reports must be submitted within 30 days of
construction completion.
A new permit must be obtained from this office for a well and/or on-site wastewater
system NOT installed by the expiration date. However a new permit can be issued free of
charge for a second year if the application for the renewal is received on or before the
date of expiration of the original permit for which a fee was paid.
When applying for a new permit after the original permit has expired or for more than a
second year, the fees are: $320.00 for an on-site wastewater permit and $120.00 for a well
permit.
If you have any questions, please call this office at 343-4744.
JamesSince~~p~ Cross, PE /Q ' '~
Program Manager
On-site Services
enc: Copy of Permit
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box ?96650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Sep 18, 1998
Expiration Date: Sep 18, 1999
Permit Number: SW980371
Legal Description: T12N R3W SEC 15 LT 13
Design Engineer: 0804 Paul C. Ramert, P.E.
Owner Name: Kevin A. Brown
OwnerAddmss: 10550 Pacer Place
Anchorage, AK 99516-6330
Parcel ID: 015-112-28
Site Address: 010550 PACER PL
Lot Size: 186040 SQ. FT.
Total Bedrooms: 7 Permit Bedrooms: 7
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AACS0 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special previsions.
The waiver 0NR940022) granted for the existing crib to well of 90 feet shall remain in effect. The new septic tank
and 7 bedroom absorption field shall be installed a minimum of t00' from all private wells.
Received By: ./~//~ ~-~2~/~// Date:
Issued By: ~ ~'"'~ Date:
/
September 17, 1998
Ms. Donna C. Mears
Municipality of Anchorage
Department of Health and Human Services
P.O. Box 19-6650
Anchorage, Alaska 99519
RECEIVED
Dept. Heal h '?~o,l "qnChoraata
t.. human eecv ,Je
Septic System Upgrade
Brown Residence
BLM Lot 13, Section 15, T12N, R3W, S.M.
Dear Ms. Mears:
Attached for your review and approval is a copy of the revised site plan for BLM Lot 13, Section 15, T12N, R3W,
S.M., showing a 7-bedroom septic system and reserve site. The revised site plan is based on our discussions of
September 14 and 15, 1998, and replaces Attachment 3 submit[ed to you under cover letter dated August 5, 1998.
The septic tank associated with the current 3-bedroom system will be removed when the 7-bedroom system is
constructed. The existing seepage pit and associated soil absorption ~ench will be left in place to serve as a 3-
bedroom septic reserve. An additional 4-bedroom septic reserve ama is located north of the existing absorption
trench as depicted on the attached site plan.
If you have questions or comments, please contact me at (907) 563-8102.
Attachment
Paul C. Ramert, P.E.
270'1 Westwind Cir. Anchorage, Alaska 99516
(907) 563-g102
August 5, 1998
Municipality of Anchorage
Department of Health and Human Services
P.O. Box 19~6650
Anchorage, Alaska 99519
Septic System Upgrade
Brown Residence
BLM Lot 13, Section 15, TI2N, R3W, S.M.
This letter serves as a request for approval of a septic upgrade and provision of the associated construction permit.
The proposed upgrade design is in support of a home addition adding 3 bedrooms for a total of 6 bedrooms. The
current system is designed to accommodate three bedrooms and was granted a Health Authority Approval (HAA)
certificate May 9, 1994.
The upgrade will involve installation of a new independent 3 bedroom system to support the addition including
effluent from the new kitchen, and 2-½ new bathrooms. The existing system will continue to be utilized to serve the
existing 2 full bathrooms as well as a bar sink.
According to documents on file at DHHS, the original septic system was installed in June 1969, and consisted of a
1,000 gallon concrete septic tank and concrete ring seepage pit. As described in an April 1994 letter by Flattop
Technical Services (Ted Moore, P.E.), the system was upgraded approximately 19 years ago with the addition of
soil absorption trenching extending northward from the original seepage pit. No records describing the design of
the soil absorption trenching upgrade are on file; however, based on soil tests on both sides of the trench (Test Hole
I and Test Hole 2), the system appears to be constructed in soil that supports a percolation rate of approximately 1.5
to 8 minutes per inch. The original concrete tank and seepage ring are located 79 fi and 97 ft., respectively from the
well (i.e. inside the 100 ft offset from the onsite water well). By letter dated May 9, 1994, DHHS approved a waiver
request for well separation for the existing system.
Test Hole No. 1 was excavated to 14.5 feet deep by Ted Moore (April 19, 1994) in support of the May, 1994 HAA
certificate and Waiver. Attachments 1 and 2 are copies of the site plan and soils log/percolation test prepared by
Mr. Moore. The soils in Test Hole 1 were dry to the bottom and remained dry after 7 days. The monitor pipe for
Test Hole 1 remains in place and was dry when measured on July 7, 1998.
Test Hole No. 2 was excavated June 22, 1998 in support of this application. The hole was excavated to a depth of
19 feet at the location shown on Attachment 3. The soils log and percolation test results are documented on
Attachment 4. Test Hol~ 2 was absent of groundwater and the monitor pipe remained dry as of July 7, 1998. The
soil was tested at a percolation rate of 1.46 minutes per inch.
Attachment 4 is a site plan showing the existing 3-bedroom system, the proposed 3-bedroom system addition (for a
resulting 6-bedroom system), and the reserved site (6-bedroom system). Attachments 5 through 7 are supporting
calculations and elevation drawings for the proposed upgrade and reserve systems. General notes are included as
Attachment 8.
lfyou have questions or comments, please contact me at (907) 563-8102.
Civil Engineer - 8489
Paul C. Ramert, P.E.
2701 Westwind Cir. Anchorage, Alaska 99516
(907) 563-8102
Attachments:
Site Plan - Existing Well and Septic System
Test Hole # 1 Soils Log and Percolation Test
Site Plan ~ Proposed Septic System and Reserve Site
Test Hole # 2 Soils Log and Percolation Test
Calculations for Deep Absorption Trench
Elevation for Proposed 3-Bedroom Septic System Upgrade
Elevation for Proposed 6-Bedroom Septic System (Reserved Site)
General Notes
Paul C. Ramert, P.E. 2701 Westwind Cir. Anchorage, Alaska 99516 (907) 563-8102
TEST HOLE
NO.2
PROPOSEO
7-BEDROOM
SYSTEM
VALVE
10%
PROPOSED
PIT
,~/ \\
/ I 2~
~__ __x_._
LOT 1 I LOT 3A
SHELL O'MALLEY HTS
Ii# s/o
SHEDS []
-TEST HOLE NO. 1
PROPOSED
NEW
CONST.
NORTH
BLM LOT 15
SECTION 15
PROPOSED SEPTIC SYSTEM
AND RESERVE SITE
BLM LOT 13, SEC. 15, T12N, R3W, S.M.
1 INCH = 50 FEET DRAWN BY PCR
SEPTEMBER 1998
NOTE: THIS IS NOT A SURVEYED PLAT,
ALL LOCATIONS SHOWN ARE APPROXIMATE.
Test Hole # 2
Legal Description:
Date Performed:
Performed For:
2--
3--
4--
5--
6
7--
8--
9--
11--
12--
13--
14--
15--
16
17--
18--
Soils Log -- Percolation Test
BLM LOT 13, SECTION 15, T12N, R3W, S.M.
JUNE 24, 1998
KEV[If A. BROWN
Description
Peat/top soil (PT)
Reddish sandy loam (SM
Gray fine silty sand with
some gravel (SM)
Silty sand with gravel ant
organics (SM)
Silty sandy gravel (GM)
Gray silty sand with som~
gravel (SM)
~.'.; ~
Slope
I I I
-TT'-f-
- I-I-I-
- I-I-I-
- I-I-I-
- LI--I-
-I--I--I-
_ I_1_1_
-I--I--I-
Site Plan
Sec Separate Site Plan
~ _/_1.1 I I I I
Test Hole 2
Type:Date Trench 6/24/9~:II
Area: 3ff by 10ft 30sf (3'x 10') *seesiteplan
Depth: 19 ft
Water Table No water encountered
7th day Monitor Tube No water present 7/1/98
Delta T Reading Delta H
Date Reading/Test# Time (minutes) (inches) (nches)
6/24~98 Presoak 7:00 PM
End Presoak 7:30 30 >>>>>> 28
T1 - Add water 7:40 14
7:50 10 6 8
T2 - Add water 7:50 14
8:00 10 6.5 7.5
T3 - Add water 8:00 14
8:10 10 6.5 7.5
T4 - Add water 8:10 14
8:20 10 6.7~ 7.25
T5 - Add water 8:20 t4
8:30 10 6.7[ 7.25
T6 - Add water 8:30 t4
8:40 10 7
6/24/98 'f7- Add water 8:40 14!
8:50 10 7 7
Percolation Rate (T7) 1.43 MPI
Test Depth between 6 fi[ and 7 fit
20 Hole Diameter, 4 inch
I certify that this test was performed in accordance with all state and
municiple guidelines in effect on this date. Date:
Foe-. ~ BPe-.q S'~gre~:
', i
: 1.) ' All construction shffll 6ompiy with the current editi6~ .of' the
Uniform El~ Code and 16cal building codes including the most r~cent
'edition of the ~ ~ f6r
otherwise noted. '. :2¥..
2. ) The maximum sewer p~pe slope shall, b~ .3/4" per fo~t unless
otherwise noted on the plans.
The minimum sewer pipe slope shell he 1/8" per foot.
4.) All drain field pipe shall be. pieced level {no fell from one end to
the other]. Systems installed on hillsides (except mound or b~
systems] ma change elevation from one lateral to the next, but each
l%teral' sh~l be la'id level and °'goosenecks" shell he installed on the
manifold line at each lateral intersection. The "gooseneck" shall be
placed on the manifold line just downstream of the lateral tee. .
5. ] Allpipe is to be 4" d~a. A.B.S. .unless other, wise noted, except
-that perforated P.V.C. may ~e used for ora~n laterels
risk. P.V.C. pipe requires .great care ouring instaxxation to prevent
pipe crushing. : - - .. · '
6.] Septic tanks shall be'of steel construction unless otherwise noted
on the plans. Concrete tanks.ma3. be instelled upon the approvel of the
engineer. Unless otherwise note~tanks shall' be ~wo compartment style.
7.) Monitor tubes shall be'installed over each compartment i~ the teak
and in the drain field or pit (except in 'the case oz pressure
distributed mound s~stems). Drein field monitoring tubes sSall be
connected to the draln leterel with a wye and 45 bend or combo and the
tube shall extend to the bottom of the septic rock. Perforated pipe
shall be installed for the monitoring tube below the connection and
solid pipe shell be installed from the connection to the ground surface.
8.) All sewer pipes and structures shall he provided with at least 4'
of cover. 1" of rigid styrofoam.insulation may be substituted for 1' of
eerth cover to a maximum of 2 of styrofoam. Pipes running under
driveways shall have a minimu~of 6' of earth cover or equivalent
insulet~on'and earth cover. ·
9.) A clean-out shall be installed either inside the building
foundation line where the sewer exits the building or within 5' of the
outer surface of the fotmdation. Additional clean,outs shall be
installe~' every 100' of sewer line run. Clean-outs shell be
constructed with wyes and a 45 sweep. Clean-outs installed outs/de of
the building must meet current A.D.E.C. well separation reqUirements.
1~.] Septic rock' (sewer rock) shall be a minimum of 3/4" and a maximum
of 3" in least dimension, and shall contein no sand, silt or organics.
11.] 10 lineal feet of cas% iron or heavy wall A.B.S. pipe shall be
installed on both sides of the septic tank,s) -unless otherwise noted.
12.] ~aterlines shall be installed with a minimum of 8' of cover where
not lying under traveled ways or parking areas. ~ater lines installed
under treveled wa~s or parking areas shell have e minimum of i0' of
cover. 1" of rigia insulation may be substituted for 1' of cover up to
a maximum of 2" o~ insulation.
13.) All water outlets intended for use in filling tanks or equip~.d
with hose connections inside, commercial structures or multi-fam/ly
dwell.lags shell be equipped with backflow preventers.
b
MONITOR
TUBE
UPGRADE
TRENCH
SEEPAGE
PiT
!
EOT 1
SHELL
#1 S/D
/
SEPTIC
TANK
BARN
SHEDS "
,,' L_TEST
HOLE ,,
/
BLM LOT 13
SECTION 15
T;12N, R3W, S.M.
WELL
..... . e~----~-_.~ ~ ~o
LOT 3A ' -~
O'MALLEY HTS. - ............
WELL
WELL
LU
LOT 4A
O"MALLEY HEIGHTS
BLM LOT 13, SEC. 15, T12N, R3W.
WELL AND SEPTIC SYSTEM
SITE PLAN
I
FLATTOP TECHNICAL SERVICES I1 INCH = 50 FEET
14530 ECHO STREET I DRAWN BY TFM
ANCHORAGE, ALASKA 99516 APRIL, 1994
NOTE: THIS IS NOT A SURVEYED PLAT.
ALL LOCATIONS SHOWN ARE APPROXIMATE.
TEST HOLE
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
DEPTH
(feeQ
1-
2
3-
4-
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAG E, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
BLM LOT 13, SECTION 15, T12N, R3W, S.M.
APRIL 19; 1994
Y[JDY RECKHORN
PT
SM REDDISH SANDY LOAM
SM GRAY SILTY SAND
DENSE, DRY, SOME COBBLES
SLOPE
SEE SEPARATE SITE PLAN
15--
16--
17--
18--
19--
20--
COMMENTS:
Depth to Groundwater Date
No groundwater 4/i9/94
Monitor tube dr? 4/26/94
Clock Net Time Percometer Net Drop
Date Reading Time (minutes) Reading (inches)
B.H.
' ; - 4/19 12" presoak 12:07 ~': I 27 3/8
_.%,../~. c/ 12:21 [ 23 1/4
Add warm' 12:22 27 1/4
12:38:30 23 3/8
#1 12:48:30 10 22 1/16 1 5/16
Add water 12:49 23 1/2
#2 h00 11 22 0/16 '"1 1/2
Add water 1:00:30 I 23 9/16
#3 1:10:30 10 I 22 1/8 1 7/16
PERCOLATION RATE 8 (minutes/inch} PERC HOLE DIAMETER 6"
TEST RUN BETWEEN 5.5 FTAND 6.0 FT ·
Soils test was done to provide documentation for existing soil absorption trench.
PERFORMED BY FLATYOP TECHNICAL SERVICES. I_~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECTON THIS DATE. DATE; /7// ~.~ ,/<~ ~