Loading...
HomeMy WebLinkAboutHAMANN LT 22Hamonn Lot 22 #050-621-09 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP241345 Work Type: Septic Renewal Tax Code Number: 05062109000 Site Legal Address: HAMANN LT 22 G:0261 Site Mailing Address: 24416 WILMA CIR, BLDG BARN, Eagle River Owner: UNSU TRUST Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date: Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 10/11 /2024 10/11 /2025 93600 Q Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: A portion of the proposed drainfield is outside the 30 ft radius of the percolation test. An additional percolation test is required prior to construction of the drainfield. If results require a design change, construction shall stop pending Onsite review and approval of a change order. Please submit results with inspection report (or change order, if required). Received By: S j L' � Issued By: ( I Date: 5 Date: Parcel I.D. 050-621-09 Property owner(s) UNSU Trust Day phone (907) 230-1992 Mailinq address 24618 Wilma Circle, Eagle River, AK 99577 Site address Same Legal description (Sub'd., Block & Lot) Hamann Sub, Lot 22 Legal description (Township, Range & Section) Lot Size 93,600 _Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field r-X1 Initial r-1 Single Family (SF) FK (w/wo ADU) Septic Tank El Upgrade 1-1 Duplex (D) ❑ Holding Tank r-1 Renewal EX-1 Multiple Dwellings 0 Privy 0 (SF and/or D) Private Well ❑ Water Storage D THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: '2- 3 "L Waiver Fees: Date of Payment: Date of Payment: Receipt Number: Receipt Number: Permit No. S P '7— Waiver No. Permit App_-'- : - I October 9, 2024 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Hamann L22- 24618 Wilma Cir Septic System Permit Renewal – OSP211192 Dear On-Site Services Engineer: The permit for the construction of a well and septic system on Lot 22, Hamann Subdivision. A site visit was conducted and there have been no substantial changes to this lot or to the surrounding area since the permit was originally issued. The current design and permit conditions meet all code requirements. We therefore request the renewal of the permit for the well and septic system on this lot. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP241345, Curtis Townsend, 10/11/24 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP211192 Work Type: Septic Upgrade Tax Code Number: 05062109000 Site Legal Address: HAMANN LT 22 G:0261 Site Mailing Address: 24618 WILMA CIR, Eagle River Owner: MARGOLIN CATHERINE O & Design Engineer: FORGE ENGINEERING This permit is for the construction of: Effective Date Expiration Date: �t»cnt o Department Lot Size in Sq Ft Total Bedrooms: 6/15/2021 6/15/2022 93600 Q Disposal Field ❑ Septic Tank ❑ Holding Tank. ❑ Privy ❑ Private Well ❑ Water Storage 5 All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: j 1) A portion of the proposed dralnfield is outside the 30 ft radius of the percolation test. An additional percolation test is required prior to construction of the drainfield. This additional perk test shall either confirm that water seeps completely away in first 30 minutes in order to take 10 minute readings or (3) 30 minute readings shall be taken. If results require a design change, construction shall stop pending Onsite review and approval of a change order. Please submit results with inspection report (or change order, if required). Received By: Date: Issued By: Abfj�la coolrug Date: ZI 5 la 0:2 1 MUNIMPALITY Community Development Department - " Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-621-09 Property owner(s) Michael & Catherine Tavoliero Day phone (907) 230-1992 Mailing address 24618 Wilma Circle, Eagle River, AK 99577 Site address Same Legal description (Sub'd., Block & Lot) Hamann Sub, Lot 22 Legal description (Township, Range & Section) Lot Size 93,600 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (N all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ElUpgrade ❑X Duplex ❑ (D) Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: -535 Waiver Fees: Date of Payment: 613 �2 I Date of Payment: Receipt Number: 0762910 Receipt Number: Permit No. D)PZI I IG 2 Waiver No. Permit App_:- : :-.,:c ; June 15, 2021 MOA Development Services, On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Hamann Sub, Lot 22 – 24618 Wilma Cir Septic system design 6/15/21 Dear On-Site Services Engineer: The owner of the above lot intends to build an additional dwelling unit on the property and will need to upgrade their septic system, so we are submitting this permit application for the construction of a new absorption trench. The attached site plan identifies the location of the home as well as the well, proposed septic location and alternate site. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot is moderately sloped with grades between 20-30% running to the southwest. There is one section of slope that was cut out for the construction of a pole barn that is near 88% down grade from where we are proposing a new septic system. Based on a 46% slope of effluent influence for soils that perc under 30 MPI, we have concluded that effluent will not daylight out of the cut bank. Please see attached cross section for justification. The current design meets all steep slope provisions as stated in 15.65.210.B.4 of the MOA Wastewater Code. Historical soils tests for this lot show a slower percolation rate than what we encountered in our test hole, so we are proposing a more conservative application rate for this design. Contour lines are shown on the site plan showing the grade and direction of flow. Stormwater drainage will not impact this septic system. The new trench will be constructed parallel to the slope as much as possible. The new system will be greater than 100’ from all wells and surface water. The alternate site will consist of tying into the existing septic with a CAT III system. The proposed septic will be located greater than 12’ away from the exiting site. Please refer to the attached plan, cross section, profile page, and test hole log for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211192, Rebecca Carroll, 06/15/21 1"=50' 80' LONG x 3' WIDE, 6' EFFECTIVE DEPTH ABSORPTION TRENCH 4-BDRM HOME NOTE: SEE ATTACHED CROSS SECTION DRAWING FOR STEEP SLOPES. NO SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE DV - DIVERTER VALVE TH - TEST HOLE LEGEND HAMANN SUB, LOT 22 FEET 0 50 100 BALCONY POLE BARN 2 STORY GARAGE W/ A.D.U. ABOVE WILMA CI R C L E TH#1 560 550 540 53 0 EXISTING 1500-GAL TANK & SYSTEM TO REMAIN IN SERVICE ALTERNATE SITE FOR 5 BEDROOMS: UTILIZE EXISTING TRENCH FOR ADVANCED TREATMENT CAT III SYSTEM MIN 172 SF OF ABSORPTION AREA REQUIRED CUT BANK >46% SLOPES HAVE BEEN STABILIZED w/ VEGETATION ≥12' DVFS MT MT CO CO 6/10/21 Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEER EXISTING WELL 100' WELL RADII CO CO FCO INSULATE PIPE UNDER DRIVEWAY & MAINTAIN 25' MIN FROM WELL w/ SEWER LINE INSTALL CLEANOUTS WHERE SEPTIC LINES EXCEED 100' ≥25' CONFIRM PERCOLATION RATE PRIOR TO CONSTRUCTION Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211192, Rebecca Carroll, 06/15/21 HAMANN SUB, LOT 22 DESIGN FACTORS:SYSTEM REQUIREMENTS: 750 GPD PEAK FLOW PERK RATE: 6-15 MIN/IN (ADJUSTED) APPLICATION RATE: 0.8 GPD/SF 6' DEEP TRENCH SYSTEM TYPICAL TRENCH SECTION (NO SCALE) 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK 3' 6" 3' 2' 6" 6' NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 9' 6" BELOW GRADE (FROM HIGHEST ORIGINAL GRADE) FLOW LINE ELEVATION: 3' 6" BELOW GRADE (FROM HIGHEST ORIGINAL GRADE) TOP OF TRENCH: 6" ABOVE GRADE 750 GPD / 0.8 GPD/SF / 6' DEEP / 2 SIDES = 78.1 LF TRENCH REQUIRED (80 LF SPECIFIED) 6/1/21 Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEER Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211192, Rebecca Carroll, 06/15/21 1"=15' HAMANN SUB, LOT 22 SLOPE CROSS SECTION 6/8/21FEET 0 15 30 525' 0' 5' 10' 15' 20' 520' ~ 8 8% 46 % AN G L E OF EFF L U E N T INFLUE NC E EXISTING GROUN D PROPOSED ABSORPTION TRENCH EXISTING POLE BARNTH#1Benjamin Schiller CE 12592R EGISTEREDPROFES S I O N ALENGINEER~20% 25' 30' 35' 40' 45' 50' 55' 60' 65' 70' 75' 80' 85' 90' 95' 535' 530' 545' 540' 555' 550' PROPOSED ALTERNATE SITE 46 % ANG L E OF EFFLU E N T INFL UEN C E Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211192, Rebecca Carroll, 06/15/21 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) HAMANN L22 5/18/21 L. TIDWELL DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH TO WATER AFTER MONITORING: IF YES @ WHAT DEPTH?- 3.7 6 3 4 050-621-09 MICHAEL TAVOLIERO 12:05 5/18 1 2 3 4 5 6 0 0 16 / 2 13 16 12:16 12:27 12:38 12:48 1:00 OB Professional Engineers Stamp: 10 NO NONE 5/25/21 GM (SILTY SANDY GRAVEL w/ LARGE ROCKS) 10 10 10 10 10 0 0 16 / 2 12 16 0 0 16 / 2 12 16 0 0 16 / 2 11 16 0 0 16 / 2 11 16 0 0 16 / 2 11 16 2 13 16 2 12 16 2 12 16 2 11 16 2 11 16 2 11 16 6/1/21 Benjamin Schiller CE 12592RE GISTEREDPROFE S S IO N ALENGINEER Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP211192, Rebecca Carroll, 06/15/21 11 L=32.74'(R) NOTES: 1) DUE TO SNOW & ICE COVER, THE GRAVEL DRIVEWAYS ARE APPROXIMATE. 2) THE DIMENSIONS OF THE LOT DO NOT MATHEMATICALLY CLOSE. — (C) = COMPUTED —(R) = RECORD PLOT PLAN ___ AS BUILT —X_ SCALE 1" —5L— GRID _ SW 0261 Project No. —___ 21=0251R1_ 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates, inc. (907) 522-6476 Phone 0000Q�Opp (907) 522-4625 Fax o OFA / ppp Professional Land Surveyors kenOlangsurvey.com O `9 jonathanOlangsurvey.com®�.. A I hereby certify that I have surveyed the following described property: LOT 22, HAMANN SUBDIVISION (PLAT No. 73-173) Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated this The __'fit '__ Day of ___ tL:, i(� _____. a.4 � _, at Anchorage, Alaska It is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. 49TH ttK�e KENNETH G. LA o .LS -5202.. '.•yJ�i 0 ppo�'0f£sS10NP& Uo pp0000�� AECC963 Permit Number: Tax Code Number: Work Type: On-Site Wastewater Disposal System Permit OSP101228 05062109000 Septic MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: October 18, 2010 to October 18, 2011 Design Engineer: ANDERSON ENGINEERING Subdivision: H^MANN Site Legal Address: HAMANN LT 22 G:0261 Owner/Address: M^RGOLIN CATHERINE O 24618 WILMA CIR EAGLE RIVER AK 995779681 [) e 1. a r t m e ~ t Site Mailing Address: 24618 WILMA CIR, Eagle River Lot Size in Sq Ft: 93600 Total Bedrooms: 3 This permit is for the construction of: N Disposal Field Y SepticTank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: I0 Date: /~~//~,(/~_ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 www. muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 050-621-09 Property owner(s) Catherine Margolin Mailing address 24618 Wilma Circle Eagle River, AK Site address 24618 Wilma Circle Eagle River, AK Legal description (Sub'd., Block & Lot) Lot 22, Hamann Subdivision Legal description (Township, Range & Section) Lot Size 93,600 Sq. Ft. Number of Bedrooms Day phone .Zip Code 99577 .Zip Code 99577 THIS APPLICATION IS FOR ([~ all that apply): Absorption Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage [] THIS APPLICATION IS AN: Initial [] Upgrade [] Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: ANDERSON ENGINEERING P,O. BOX 240773 ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) September 30, 2010 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 22, Hamann Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The septic tank on Lot 22, Hamann Subdivision is failing and must be replaced. We are proposing to replace the tank with a new 1,500-gallon steel septic tank to serve the two-bedroom home on the lot. The existing absorption trench will remain in place for reuse. We are therefore requesting a permit be issued for the construction of a new septic tank on the lot. The attached Site Plan and backup documentation identify the location and configuration of the existing septic system and the location of the new tank. The existing well is also shown with its 100' protective radius. The wells on the adjacent lots are also shown and the new tank will be placed at least 100' from these well and 100' from any surface water. The existing tank on the lot will be disposed in accordance with Municipal Code. The drainage patterns will be maintained after construction. The ground surface on the lot is basically flat in the area of the new tank. The new septic tank will be constructed near the location of the existing tank and as parallel with the slope of the land as possible in conformance with Municipal requirements. If the tank is constructed in accordance with our design the following statements apply: The tank, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The tank, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. Lot 22, Hamann Subdivision September 30, 2010 Page 2 of 2 The tank, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The tank, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments HAMANN SUBDIVISION LOT 22 93,600 S.F, / Dispose of Existing Tank in -~--/... Accordance with Municipal Code. / Place New 1,500 Gallon SeptiB'" / Tank, and 2 Post Tank Cleanouts. / / / ~ ~ Bedroom ExisUng AbsorptionTrench ~ ~ / 49' Long x 2.5' Wide ~ ~ / x 5.5' Effective Depth ~ / NOTE No Conflicts With Wells or Septic Systems in the Area. N~ Breaks in Grade >25% Within 50 of New -~ Septic Tank. ~ ¢~ / ~~ Vent ~/ - -~ ~ / TH - Test Hole ~.>. ~ / ~o -'~,on c,.~ o~, - SITE PLAN MUNIC;IPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SER¥1CES Environmental Health Division 825 "L' Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Address DISTANCES Lot Township, Ra~qge Section SEPTIC TANK ABSORPTION FIELD WELL WELl_ V'~ c;::> ] LOT LINE \o /'-~'- ~, ~I-W~ --~ FDUNDATION ")....cs, / ~ / ~ AS-BUILT DIAGRAM {Show Iocahon OI well, septic system property hnos, foundatron, ~-~ SEPTIC [~ HOLDING TYPE OF SYSTEM "~rRENCH [] BED [~ W. DRAIN ~ OTHER Fill added above original grade G[avel depth bonealh p~pe FT WELLS ~RIVATE [] OTHER ¢ldentifv) REMARKS: FT Inspecti~]ed by $ & S ENGINEERING ~ 17034 Eagle River Loop Roa(J No, 204 I ~,lt~Jo~J~cj¥,ejCr~Sk~Lg-,9~L____---_.-.-/~ cerl~y that this inspection was pedormed according to all lale ~u~d ~~~¢ ~ ...... .... , ~, i ii !;ii. :';ii; {::~..i i;ih:;, ~ '~')': 'c:i :,;ici ~.:.'([. ~ ;::~i;~, ;:i i :,' ,;;,'~ [.~ ,., ~ Municipalily o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG b PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 2 3 4 7 ~2 14 15 16 17 18 19 2O COMMENTS { E N G I N E ER'8~'~'~\~ >, ,'~, DATE PERFORMED: [C~~,,,~;~ ,.[.~,~'~ ~,N ~--, Township, Range, Soction:~, ~. SLOPE ' si-rE PLAN _-y_ WAS GROUND WATER ENCOUNTERED7 $ L IF YES, AT WHAT O DEPTH? p E Deplh to Waler After NIoniloring? ~ Reading Date Gross Net Depth to Net Time -rime Water Drop PERCOLATION RATE "~"'"~ (m~nules/,nch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FTAND __~:) _FT S & S ~CNGINEER!N¢_- 17034 Eagle River Loop Road No. 204 E a 9 I~dti ,~r-5,A ~ ¢[',~ 9!/577 PERFORMED BY: ¥'~--__/I/'----~ I CER1 IFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE Ah~D MUNICIPAL GUiDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) (GRE'"ER ANCHORAGE AREA BOP°'UGH Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 /~INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME ,/~' ~'- ~¢L-~-~d-,..,,%¢~ MAILING ADDRESS //../~';'",',~/~/'7 ~?../C), PHONE SEPTIC TANK: DISTANCE EROM WELL /~T'¢ '''/- MANUFACTURER INSIDE LENGTH _ INSIDE WIDTH NUMBER OF COMPARTMENTS / LIQUID DEPTH__ LIQUID CAPACITY ,/'/J --,7 -~'.,' GALLONS. SEEPAGE PIT: NUMBER OF PITS / DIAMETER OR WIDTH /-¢'- /LENGTH /'7, / DEPTH ¢ ¢~ // t LINING MATERIAL/~,Z';¢./~.~""¢~i:RIB SIZE: DIAMETER___.DEPTH ~ / DISTANCE FROM: WELL BUILDING FOUNDATION_ ~'~[) / / NEAREST LOT LINE -,~20 £'/-' TOTAL EFFECTIVE ABSORPTION AREA (WALL. AREA) sq. FT. ADDITIONAL ABSORPTION ~ X~ ~ o,. ....... ~,_ ~,-- WELL.: TYPE ,~0¢,.-~.~¢.~.~) . _CONSTRUCTION BUILDING NEAREST FOUNDATION LOT LINE CESSPOOL OTHER SOURCES APPROVED /~-~- DISAPPROVED NEAREST SEWER LINE REMARKS DEPTH / '~' ~ ! DISTANCE FROM: SEPTIC TANK /'~'~ /:/- SEEPAGE SYSTEM .,/~-'Z., / ¢' DISTANCES: INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: Form No, EQ-031 DIAGRAM OF SYSTEM DATE V'~ <'~ /''~''1' '' G.A.A.B, GRE, .:R ANCHORAGE AREA BOr UGH PERMIT NO. DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE:, ALASKA 99503 fl, . J { SEWAGE DISPOSAL SYSTEM ~ APPLICATION AND PER~[T INSTALLATION LOCATION LEGAL TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH C'/] " SOIL TEST RESULTS / ~- ;/ ~ / ~- / COMPLETION DATE ANTICIPATED __ '~]~-¢ ¢~ ~'`~; TO SE INSTALLED NY NOTE~ THIS PERMIT IS NOT VALID WITHOUT ~OIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED, BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION bY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE ~ TYPE SEEPAGE AREA SIZE TYPE DIAGRAM 01" SYSTEM MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTfC TANK SEPTIC TANK J TO NEAREST LOT LINE. WELL. TO SEPTIC TANK DRAIN FIELD · DRAIN FIELD , SEEPAGE PIT . / · DRAIN FIELD //d ",/ / SEEPAGE PIT ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK , SEEPAGE PIT DRAIN FIELD SEPTIC TANK .... SEEPAGE PIt ,DRAIN FIELD TO RIVER, LAKE. STREAM. / /d/: CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION S FEET INTO UNDISTURBED SO]L. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT CAPS. OR LICENSED DESIGNER I CERTIFY THAT ] AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGN ORDINANCE NO. 28-88 AND THAT THE ABOVE ! Performed for Legal Description: This form reports: GREATER ANCtlORItGE AREA BOROUr'' Department of Environmental 3330 "C" Street Anchorage, Alaska 99503 SOILS I,OG - I>EROLATION TEST BOb Hamann Soils log Depth Feet Dry Reddish Silt Date Pe rfo rmed____~6./_12~Z2_5 Hamann Subd iv i s_iD_n~ YES .... Percolation test 5 .- Dry Grey Silty Sandy Gravel 6- 150 S.F./B.R. 7 ~ with occasional boulders 12" ( Maximum) ...... -~. - I -'h , 13-- t~om ~-es t Was ground water encountered? NO I f yes, at wha'l: depth? Reading Date Gross Time Net Time _?e_p_t?]_~.~W~te_r_ Net Drop l~roposed installation: ~eepage Pit ~gS Urain Field bopth of Inlet Depth to bottom of pit or ~rench OWNER OF LAND .~,dq ~ e"~r~ ~' T' ~3 ~ ADDRESS ~ /~' ¢;)~ O3-b(a ~ I~ ST.VI'IC LEVEL OF WATER FF. // ~ . LEGALDESCRI~ION ~ ~ ~q~ ~' DRAW DOWNFT, DATE-Started ~~ Ended GALS. PERHR ~ ~ OO . PERMIT NUMBER r~ KIND OF CASING ~ KINDOFFORMATION: ~ ~[~C hC~qS~q' ~ ~ ~ ~/ ~/ ~ ~ ~/(~; ~ ~ From~ Ft. to~Ft. ~/~ C~ y Frmn Fi. to, __Ft. From __ Ft. to Ft. ~ '~ ~"'4~'t~. From~ Ft. to_. __ Ft. From/~-'~ Ft. to Ft. ~':'~'b-,~o(../C From__Ft. to __Ft. From Ft, to Ft. From__ Ft. to. __Fl, From Ft. to Ft From Ft. lo.__ Et From____Ft. to Ft. From Ft. to Ft. From __Ft. to__Ft._ From__Ft. tn. __Ft. From __ Ft. to Ft. From From __ Ft. to Ft. From From __ Ft. to Ft. From From Ft. to , , Ft From From Ft. to__Ft. From__ From Ft. to Ft. From__Ft. to Ft. From Ft. to Et, From Ft. to Ft From__Fi. to Ft. From__Ft. to___Ft. From__Fi. to Ft. From Ft. to Ft. From__Ft. to Ft, From Et. to Ft. Z o, 0 0 0 0 0 0 0 0 [~ .~.I~ON,"vi~NTALJ P,ROTScHoN . Municipality of Anchorage _.~.,, Development Services Department Building Safety Division On-Site Water & Wastewater Program ~ " 4700 Bragaw Street P.O. Box 196650 -- Anchorage. AK 99519-6650 www.muni.org/onsite ~, C.. -- I ~,~,~,0.~1 ( ~.~ (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEHS ,b, PPROVAL FOR ,b, SINGLE FAMILY DWELLING Parcel I.D. D~'O- ~1'~ 1. GENERAL INFORMATION Expiration Date: Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address HAMANN SUBDIVISIONI LOT 22 24618 WILMA CIRCLE MICHAEL ROY 24618 WILMA CIRCLE EAGLE RIVER, AK 99577 Day phone * EAGLE R~ER, AK 99577 Day phone 694-4640 EVA LOKEN w/PRUDENTIAL ~STA Day phone 689-6476 16635 CENTERRELD DR. * EAGLE RIVER, AK 99577 Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBEROF BEDROOMS: 2 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a pedod of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further vedfy that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. NameofFirm CARNESS ENGINEERING CROUP, Ltd. Address 3701 E. TUDOR ROAD, SUffE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. CARNESS, P.E. Phone 337-6179 Date L~I oq/O~ Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engieeedng analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the pedormance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may tTuctuata dudng the year, and the water usage of the family being served by the system. These conditions ara outside the control of the evaluator of the system. Satisfactory test' results do not guarantee future performance of the system, nor do they guarantee that there ara no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or futura estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or uae of this report by any other person or party is not authorized, nor will it confer any legal Eght whatsoever. 5. DSD SIGNATURE ~ Approved for ,~ bedrooms. Disapproved. Conditional approval for __ bedrooms, with the fllowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory (Roy 11/05) Arsenic Advisory Maintenance Agreements Supplemental Engineer's Reort Other Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www,rnuni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS .&,PPROVAL CHECKLIST Legal Description: HAMANN SUBDIVISION~ LOT 22 Parcel ID: O.~'"O ' ~. ,,~/' OcJ A. WELL DATA *WELL DEEPENED :, Well type pRIVATE IfA, B. or C provide PWSID# N/A 6/26/1975 Date completed .7/1985 Sanitary seal (Y/N) YES Total depth 158 ft. Cased to 158 ft. Well Log (Y/N) YES (2) Wires properly protected (Y/N) YES Casing height (above ground) 12 In. FROM WELL LOG Date of test 7/1985 Static water level 115 ft. Well production 10 g.p.m, AT INSPECTION 5/22/2007 105 :7 ft. ,g.pm. WATER SAMPLE RESULTS: Coliform __ 0 colonies/100 mi. Nitrate 0.129 mg./L. Other bacteria Date Of sample: 3/28/2008 Collected by: 0 Colonies/lO0 mi. GEG Ltd. System type ***CRIB/TRENCH Gravel be!ow pipe 6/5.5 ft. Depression over field. NO Date of adequacy test 5/22/2007 Results(Pass/Fail) PASS · For 2 bedrooms Fluid depth in absorption field before test 7.5' in. i Water added 385 gal. New depth 21.5in. Elapsed Time: 360 min. Final fluid d~pth 17 in. Absorption rate >= 300+ g.p.d. Any rejuyenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes. give date - · *TESTED THE 1987 ***A DIVERTER VALVE WAS INSTALLED ,-, 8/2000 iTO RECONNECT THE SYSTEM ON 5/22/2007 CRIB PER THE 8/17/2000 HA~,. = C. ABSORPTION FIELD DATA: ~BELOW EXISTING GRADEI 6/1975 ' 150 Date installed .'11./7./tg67 Soil rating (g.p.d./ft~0~ 268 Length 15/49 f~. Width 17/2.5 ft. I , . 384 : . Totaldepth "8.83 ft. Eft. absorption area 539 ft2 Monitoring tube YES Date of pumping 5/21/2007 Pumper. ~ JR'S PUMPING High water alan-n (Y/N) Arsenic: ND ug./L. B. SEPTIC/HOLDING TANK DATA Tank Type/Material STEEL Tank size 1000 ,gal. : i NumberofCompartments 1 Foundation cleanout (Y/N) NO Depression over tank (Y/N) NO Date installed Clean0uts (Y/N) N/A 6/1975 YES D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) ~ on" level at ~el at ~ .in. "Pump ~ ~ C~s alarm & circuit requirements?. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorptioh field on lot 100% Public sewer main N/A Sewer/septic service line 25'+ Animal containment areas 50'+ 100% On adjacent lots, 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line Water main N/A Water service line 10'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation. 10'+ Water service line . 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacentlots 100'+ F. COMMENTS Absorption field 5'+ Surface water. 100% Water main N/A Driveway, parking/vehicle storage 10'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer*s Printed Name JEFFREY A. GARNESS Date COSA Fee $ Date of Payment Receipt Number (Rev, 11/05) Waiver Fee $. Date of Payment Receipt Number. Municipality of Anchorage Development Services Department Building Safely Division On-SiteAnchorage,Waterwww.munl.org/onsite4700P.o.Bragaw &Box Wastewater AK19665099519-6650 Street Program ~-~ ~~) (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEhlS ~,PPEOVAL FOR ~, SINGLE FAHILY DWELLING Parcel I.D. ~'):~'~ --~q/- ~ COSA#~[0 ~ ,. OE,E ''"FORMAT'O" - / =:O 7 ........ Complete legal description Location (site address) Current Property owner(s) . Mailing address Lending agency' Mailing address Real Estate Agent Mailing address HAMANN SUBDIVISIONI LOT 22 24618 WILMA CIRCLE * EAGLE RIVER, AK 99577 MICHAEL ROY Day phone 24618 WILMA CIRCLE * EAGLE RIVER, AK 99577 Day phone 694-4640 EVA LOKEN w/PRUDENTIAL ~STA Day phone 689-6476 16635 CENTER,ELD DR. * EAGLE R~ER, AK 99577 Unless otherwise requested, COSA.will be held by DSD for pickup. 2. NUMBEROF BEDROOMS: 2 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site ~ Individual Holding tank Community On-site ["] Public Sewer ' [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system, DSD also Issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work, 4. STATEMENT OF INSPECTION BY ENGINEI~R As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation, based on procedures outlined in .the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedreoms and type of structure indicated heroin. I further vedfy that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. NameofFirm GARNESS ENGINEERING GROUP. Ltd. Phone 337-6179 __Add_res_s__ 3701 E. TUDOR ROAD, SUITE 101 * ANCHORACE, AK 99507 --;2 ........ Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide e thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered et the time of tho test. and separab'on distances measured to readi/y identifiable features. The operational life of ali wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, end the water usage of the family being served by the system. These conditions are outside the control of the eva/uator of the system. Satisfactory test results do not guarantee futura performance of the system, horde they guarentee that there ara no hidden defects or encroachments. GEG. LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. Tho content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor wi//It confer any legal right whatsoever. 5. DSD SIGNATURE ~ Approved for ~ bedrooms. Disapproved. Conditional approval for bedrooms, with ihe fllowing stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Reort Other Municipality of Anchorage Development Services Department Building Safety Dh'isbn On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage. AK 99519-6650 www.muni.org/on~ife (~07) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: HAMANN SUBDIVISION~ LOT 22 Parcel IO:j~_~_~ .... WELL DATA *WELL DEEPENED Welltype PI~VAI~ . ffA, B. orCprovidePWSlD~ N/A 6/26/1975 Date completed *7/1985 Saniten/seal (Y/N) YES Total depth 158 ff. Cased tn 158, ft. Wall Log (Y/N) YES (2) Wires properly protected (Y/N) YES Casing height (above ground) 12 in. FROM WELL LOG AT INSPECTION Date of test 7/1985 5/22/2007 Static water level 115 ft. 105 fl. Well production 10 g.p.m. 7 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mi. Nitrate 1.87 mgJL. Other bacteria 0 colonies/100 mi. Arsenic: ND ug.lg Date of sample: 5/22/2007 Collected by: GEe Ltd. B. SEPTIC/NOLDINO TANK DATA, C/O IS THROUGH TOILET IN HOUSE OK. PER DAN ROTH Tank Type/Material Tank size 1000 gal. Foundation cteanout (Y/N~) YES Date of pumping 5/21/2007 STEEL Number of Compartments 1 Depression over tank (Y/N) NO Date installed 6/1975 Cleanoufe (Y/N) YES High wamr alarm (Y/N) N/A Pumper JR'5 PUMPING C. ABSORPTION FIELD DATA pBELOW EXISTING GRAD~ a/1 $75 150 Date installed *e11/7/lga7 Soil rating (g.p.d./ft~oK~ 268 System type ***CRIB/TRENCH Length 15/49 ft. Width 17/2,5 ff. Gravel balow pipe 6/5.5 ft. 584 Total depth ,8.83 ft. Eft. absorption area 5,~9 Its Monitoring tuba YES Date of adequacy test 5/22/2007 Results (Pass/Fail) PASS Fluid depth in absorption field before test 7..5. in. Water added ,385 gal Elapsed Time: ,360 min. Final fluid depth 17 in. Absorption rate >= 300+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date - (**TESTED THE 1987 (***A DIVERTER VALVE WAS INSTALLED ,-, 8/2000 TO RECONNECT THE SYSTEM ON CRIB PER THE 8/17/2OO0 HAA). 5/22/2007) Depression over field. NO For 2 bedrooms New depth 21.5 in. D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N} "Pump on" level at ~1 a7 Datum ~ ..------- Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tenkJlift station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A Sewer/septic sewice line 2.5'+ Animal containment areas 50'+ On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line Water main N/A Water service line 10'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Absorption field 5'+ Surface water. 100'+ Water main N/A Driveway, perking/vehicle storage Property line · 10'+ Building foundation 10'+ Water service line 10'+ Surface water 100'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS 10'+ G. ENGINEER'S CERTIFICATION I certify that I have determined through field in~s and review of MuniCipal records that the above systems are in conformance with MOA COSA guidelines in effect on this dats. Engineer's Printed Name JEFFREY A. GARNE. SS D.te COSA Fee ~; ~/ Date of Peyment Receipt Number Waiver Fee $ Date of Payment Receipt Number ASBUILT I HEREBY CERTIFY THAT I HAVE SURVEYED THE FOLLOWING DESCRIBED PROPERTY.' AND THAT NO FNOROACHMENTS EXIST EXCEPT AS INDICATED. IT IS THE RESPONSIBILITY OF THE OWNID::{ TO DETERMINE TH~ EXISTENCE OF ANY EA~EI~ENTS, COVENANTS~ OR RE.~;TRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDI- VISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON BE USED FOR CON~JTRUCTION OF FENCE LINES, OR FOR ESTABLISHING BOUND- ARY LINES. (;RID: FB~ "B £WN, I! Municipality of Anchorage Department of Health and Human Services Division of Environmental Services On-Site Services Section 825 "L" Street Room 502 P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel.I.D..O ~'~ -(., ~.t -C q 1. GENERAL INFORMATION Complete legal description Lot 22, Hamann HAA#_ ./~',/?L"~'_ .~.' Expiration Date: Location (site address or directions) Current Property owner(s) Bruce & VirRinia Mailing address % Remax/ Kathi Lending agency Mailing address 24618 Wi}~t Circle Morton Day phone 694-9112 Day phone Real Estate Agent Remax g.R/Kathi 01instead Dayphone 694-4200 Mailing Address 16600 Centerfield Dr., Ste 201, EaRle River, AK 99577 Unless otherwise requested. HAA will be held by DHHS for pickup. HAA picked up by: . ~ f. ~ NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Public Water System Well 2 TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] [] Individual Holding Tank [] [] Community On-site [] [] Public Sewer [] The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Certificates of Health Authcrity Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the Slate of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) on properties served by a single family on-site wastewater disposal and/or water supply system. DHHS also issues HAAs upon request to home owners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissicns in the professional engineer's work. o STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation based on procedures outlined in the Health Authority Approval Guidelines for the Health Authority Approval application show that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on- site water supply and/or wastewater disposal system is in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. S & S ENGIN££RING Name of Firm 17o.34 F .1 -"~ ~ ~v~r Loop Road No.~.02J Eag!a i~,ivar, Alaska 99577 Address Phone Engineer's Printed Name Rober I: Cowan Date DHHS SIGNATURE Approved for ~ bedrooms. Disapproved. Conditional approval for __ bedrooms, with the following stipulations. Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Expiration Date: //_......._.3 ~ 0 .c Original Certificate Date: Reissue Date: 75 0;5~Rev 01 00F RECEIVED Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICI~I~(~ Environmental Services Division 825 L Street, Room 502. Anchorage, Alaska 99501. Legal Description: Health Authority Approval Checklist Z-~; ~(~-v'f~/ ~'/0 Parcel I.D.: 0 A. WELL DATA Log present (Y/N) Total depth / ~'~. / If A, B, or C, attach ADEC letter. ADEC water system number FROM WELL LOG AT INSPECTION o.,.o,,.. wamr Well p~on ]~ g.p.m, g.p,m. WATER SAMPLE RESULTS: Coliform -I;;7 Date of sample: e. SEPTIC/HOLDING TANK DATA Nitrate /' '~"~- Collected by: Other bacteria Data installed Foundation c~ear~ut (Y~) C. AOSOR~ON RE~ DATA* Len~ / ~ ' w~m Tank size /lf'~ ~ Number of Compartments / Cleanout~/N) /~'3' ~/0 High water alarm (Y/N) ~ /~f Depression (Y/~ Pumper ~T~ ',~ Soilrating (g.p.d./ft~or~/bdrm) /'~-'~ ~ Systemtype Gravel thickness below pipe ~, ' Total depth Effective ~q~tion area __,~4~" Monitoring Tuba presentfl/N) Y~'d' Depression over field (Yb A.! Date of adequacy test Results all) ~ For T~6/~ bedrooms Fluid depth in absarptlon field before test (in.): ~'~ Immediately afte~"gaJ, water added (in.}: Fluid depth ~ ~. (ins) Minutes later: ~ Absorption rate - "/..~0 0 g.p.d. Peroxide treatment (past 12 months) (Y/N)-~/AV~- ~W&#A~-~t yes. give date 72-026 (Rev. 3/96)' D. UFT STATION Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested E. SEPARATION DISTANCES /// Size in gallons "Pump on" level at* 'Datum "Pump off" level at' Septic/holding tank on lot Absorption field on lot Public sewer main SEPARATION DISTANCES FROM WELL ON LOT TO: /0'3 Sewer/septic service line On adjacent lots On adjacent lots Public sewer manhote/cleanout Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation ~ t '-/- Property line ~'~ t'*t' Absorption field Water main/service line /4~ ~ Surface water/drainage ,/~"7 ~-- Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line / 0 /.~. Building foundation / c~ /~- Water main/service line Surface water / ~'~ ~ ")- Driveway, parking/vehicle storage area Curtain ! /0 /o /~.A/fl"l,d A/~ Wells 0n adjacent lots t/d...fl r F. ENGINEER'S CERTIFICATION I certify that I have determined thru field inspections and review of Municipal reco~s are Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)*