HomeMy WebLinkAboutT12N R3W SEC 33 LT 138T12N, R3W Section 33 Lot 138 #018-292-09 Municipality of Anchorage R l Development Services Department 3� "yet \� Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 Page/ of L www.cl.anchorage.ak.us (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: 543 c k O O? 16 PID Number:2— Nan" P �; (- C• ot( L0,101 Wastewater System: []New Upgrade A0 ess3?` Pclr r i ABSORPTION FIELD Pnwr 3 (n N'•Wr of Be Mown 13 DW DTrwVh O She"" Trwlrll D Bed MPUM OPw LEGAL DESCRIPTION Sat RMaq 40 GpotFI' Tar Depen ewn wv r i pate 2.5� FI. BIO* Lw SWa son DaWh b ppe W= Ian Ong nY Vat• Drina!death beneath ppe / Y2— Ft. FI TavnWnP Range section FA atdat Wave w9nel grata ?_'D -Ft. GI" Length 60 3 Ft. Well: ❑ New ❑ Upgrade Greta wbtA /S Hunger M Ines 3 D.Vance baaveen Ines 3 Ft. FI CI.VK m(Pmwe. A It. C) iwY Depth, aaedb TOM Wwrpmi Yea q VO Poe Mat" 3U3q FI. FI Fit I DnW Me DMW Sutra Www LMI IutMier OMs InMMbd /2- N v, T»a Pwro Se M c...ng H•Vu Abov. Draan TANK CPM FI. FL SEPARATION DISTANCES VSeptic ❑ Holding ❑ S.T.E.P. ❑ Other. To From Septic Tank Absorption Field Ldt Station Holding Tank dvate Sewer Line ad1ir A w1i- a. k. tT / Z SO GM Wait /aoT /oo 1\1`4', 5-0,1. MWe"M NunWw a caro stwacewMar /v0 F /00' LIFT STATION Lw Loa S(�' E.}. .S v'/- Sao Gat E/�• t� 'Poop On' level M 'Pump PIr lev Hqh wales MYw at FvuM 2 t) Zt1` M in H. N/T N PwnP MNe a EucP cM haPe 4a^. pMamud M C~Dron R.m«Ia 4 rtz) y f3 e'6 too qti�/ rl. ' BENCH MARK / t 7- iWi0amr- LVer CU Loraum w Dseaipuan weirt I Z S O eun� w'•� A4 CL L aA' An 10C) FL Inspections performed by: Mt rk4Y(Af _Ar 4 teja ti Dates: 1" ���u'��N q :, t O t aq I eat ow h~� s�yl+ •••:Ij Development Services Department Approvaltoo*:49TH• Conditional Approval Date: MICHAEL N. ANDERSON I �•, CE-9469 • `�� Reviewed and approved by: v Date: $ -//�0 S (Rev 04U6) �1>°� ROfESSi����= Permit No. SW080078 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description: T12N,R3W,SEC33 LOT 138 PID No.: 018-292-09 MARK A 8 D GRN ELE PIP ELE FCO 9 20 108. 96.5 C01 43 48 103. 96 CO2 45 49 102. 95.8 TC01 48 50 100. TCO2 40 42 100. CO3 37 a0 100. 95.2 MT1 6 75 102• MT2 5 60 102. VALVE 2 22 102.8 AIR LINE 4 102.6 R LINE C / VIE . ENCH, T P OF WELL CASING \� o V / o C I Asevllr I I topto- WO TC01 R:ot s ao m, a •n e i � •.. e e i �;•• I, �� :o rR, w a �r"j -'0 a0.c a 49 T" ••I� �hR9 r.e.c • e0unro' • .. • nuouuu:uo.0 f 2So :..�. ao v ,.�1. ....... ...� r..+c...o+ .sl c 1. '- ♦ �`': MICHAEL N. ANDERSON.. -- O^O OM.fAM V[eK,YLLO rP MVK 11f[ -100 �1 Gam• No. CE 9469 N.T.S. MUNICIPALITY OF ANCHORAGE Development Services Department 1 On -Site Water & Wastewater Program 1 4700 South Bragaw Street O P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 A ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Jun 06, 2008 Expiration Date: Jun 06, 2009 Permit Number: SWO80070 Parcel ID: 018-292-09 Legal Description: T12N R3W SEC 33 LT 138 Design Engineer: 0088 ANDERSON CONSTRUCTION & E Site Address: Owner Name: PHILLIP CALHOUN Lot Size: 108900 SO. FT. Owner Address: 3260 PORCUPINE TRAIL Total Bedrooms: 7 Permit Bedrooms: 7 ANCHORAGE. AK 99516 - This permit is for the construction of: ❑,/ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, Alaska 99519.6650 www.muni.org/onsite (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 0 11Z_a9a- Oji Property owner(s) / ,Ar Ne v fQ Day phone 2 f0 - Z -3.3 S Mailingaddress -326o ifo�zt yrl"Jf :f2KVt Zip Code 4`7S16 Site address 3ZF. n -trZA I L Zip Code Legal description (Sub'd., Block & Lot) 7120 `R 3W SQL �J�j C�13� Legal description (Township, Range & Section) Lot Size IOFB. 90Q Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field [� Septic Tank Q Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms THIS APPLICATION IS AN: Initial ❑ Upgrade [� Renewal ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: /157- Waiver Fees: Date of Payment: �p Date of Payment: Receipt Number. I 0 a$5 Receipt Number. (Rev. 11105) Michael N. Anderson, P.E. Civil/Structural Engineering R. Construction 4661 Natrona Avenue Anchorage, Alaska 99516 Phone 345-3377 Fax 345-1391 May 28, 2008 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 Re: T12N, R3W, Sec 33 BLM Lot 138, Tax ID 018-292-09 To Whom it may concern: This is a request for a new septic permit on the above lot. The lot size is 2.5 acres, typical for the area and the lot to the west is vacant. The test hole excavation revealed poor graded gravel (GP) for 10 feet with, with water observed at 6.5 feet after the 7 day monitoring period. The perc rate was 1 minutes per inch at elevation —2 feet, in the gravel. The owner has asked for a 4 bedroom addition to match the 7 bedroom house. A 24" sand layer has been added to slow the perc rate into the existing soils. All the lot has a gentle slope of about 3 to 5 percent from the east to the west, as shown on the plan. The neighboring lots will not be impacted by this new septic due to the large lot size. If you have any question please call me at 345-3377 Sin Cerely�— Michael N. Anderson, P.E. I. 1% SLOPE PROPOSED DRAII 0% SLOPE 1yo / / ghAINFIELD I _ -------- 600• 0% SLOPE / cI THP r \ \ / \\CO % \ EXISTING POWER POLE / / / � TOE OF SLOPE EXISTING FOUNDATION / N—EXISTING SEPTIC LINE CO / EXISTING HOUSE / / EXISTING SHED TOE OF SLOPE / / / THIS SITE IS AT THE BOTTOM OF EXISTING LINE TO BE REMOVE ^S A STEEP SLOPE HOWEVER NO -T CO�SLOPES OR BLUFFS GREATER .. THAN 25% WITHIN 100' ARE EXISTING SEPTIC TANK LOCATED DOWN SLOPE OF THIS 0 SITE. C NEW 1250 GALLON SINGLE COMPARTMENT SEPTIC TANK SEPTIG—T,4 K Ac`arrs wny eu i.r N•ti• lj- Septic Design Prepared For PHILLIP & SONNETT CALHOUN BUI LOT 138, SECTION 33, T12N, R3W, SEWARD MERIDIAN Anchorage, Alaska Prepared By MICHAEL N. ANDERSON, P.E. 4840 SHOSIIONI DRIVE (907) 345-3377 / FAX (907) 345-1391 SCALE: 1"=30' JUNE 2, 2008 DESIGN CRITERIA: MOUND OVER (THII) b GRADE 4 BDRM X 150 = 600 GPD 05' ORG SOILS = 600/0.7 = 857 GPD FILTER FABRIC 857 GA/15 = 57' USE 60' '0 PIPE W/ 6' -1.5 Z.�SEWER ROCK (1) BED GM - "y 24' FILTER SAND 15.0. 3.5 DEEP F 0. 0.5' EFFECTIVE 15.0' WIDE 0O1A P�� Lj 60' LONG 100 19 D OT 120 PROPERTY 7NE �} -PORCUPINE TRAIL- . / EXISTING WELL . PROPO ED SEPTIC 100' RADIUS K . � LOT 139 LOT W > VACANT z - LOT 138 J 0 -A o ExIs'nwG SE z= o RESERVE Al EA FOR 7 BEDROOM N J ADVANTEX SrEM, 15 X 45 SAND 3 _ FILTER TYPICAL o 3 z LOT 151 LO 52 LOT 153A VACANT �3 -150TH AVE - Septic Design Prepared For PHILLIP & SONNETT CALHOUN .�P�E.�••...••,\���! DLM LOT 138, SECTION 33, T12N, R3W, SEWARD MERIDIAN : �, ' �# Anchorage, Alaska 1ts;° 49TH �? t;*00io i,.�...i.i�... .t..........:t.....00 Prepared By MICHAEL N. ANDERSON, P.E. i' "" ' ....�..` 1....... ♦ c^ t; Michoel N. Anderson i 4640 SIIOSIIONI DRIVE ♦ 0 �#'%... CE-9469 �a (907) 345-3377 / FAX (907) 345-1391 •� #F4 �F'ESSO i� �• \\ .._ JUNE 2, 2008 SCALE: 1 —100 Municipality of Anchorage Development Services Department Bulling Safety Division �I On -Site Water and Wastewater Program 4700 South Brdgaw SL P.O. Box 196650 Anchorage. AK 99519-6650 v cl anchora4e.ali.us (907) 3437904 Performed For: Legal Description: 4- 5 - 1 1 �1�"E3L+�11r��A�l ry� • t *-*49TH* r^ >• MICHAEL N. ANDLRSC:4 : _1 ,•, CE -9469 / Soils L/o/g, - Percolation Test 1 1, I r rp L✓ I a, n __Date Per:ornad: h (• A f /6, F 1,3 -2 Tovmship, Range. Section: -f// ai C-� M Leese 14I.(t6, C•'D+e d•C yY,,.f-( COMMENTS Site Plan Y\ Reading Date WAS GROUND WATER �^l�r5 9- Net Drop ENCOUNTERED? 8 til d P, - sn•k IFYES,ATWHATOEPTH7 /.t7 L O BO f� 6 M Depth to Water After P 1_ MonlImIng? blt; E 2- Data S 2 COMMENTS Site Plan Y\ Reading Date Gross Time Net Time Depth to Water Net Drop 1=0 til d P, - sn•k z . • ' r, (o L^ PERCOLATION RAT= -!E- IIrvx:4ssrci) PERG POLE DIAMETER to TEST XJN8ElNE=N 3 Fi AND 3,117_ FT PERFORMED BY: tj1 hT-,I,j,•F40A ) CERTIFY THATTHIS TE ST AS/ PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: T 7 tJ Municipality of Anchorage Development Services Department Building Safety Division yr On -Site Water and Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www d anchorace.ak.Us (907)343-7904 Performed For: Legal Description: n Soils Log Percolation Test (of our, - Date Per'onnM: �j L)1/' L -v -F t 02,< Township, Range. Section: q.rile r, N g0 "N 12- 13- 17- 18 - WAS GROUND WATER ENCOUNTERED? a IFYES.ATWHATDEPTM �r L O Depth to water after Monitoring? L. E Date:S Z� O(+ Ste Plan Readng Date Gross Time *:49TH'' Depth to Water Net Drop z/ o� ..0• MICHAEL N. ANDLRSCN : `- •, CE -9469 ••`,�� n Soils Log Percolation Test (of our, - Date Per'onnM: �j L)1/' L -v -F t 02,< Township, Range. Section: q.rile r, N g0 "N 12- 13- 17- 18 - WAS GROUND WATER ENCOUNTERED? a IFYES.ATWHATDEPTM �r L O Depth to water after Monitoring? L. E Date:S Z� O(+ Ste Plan Readng Date Gross Time Net Time Depth to Water Net Drop z/ o� NoP �— so. 2 „ d r to„ d /r r PERCOLATION RAT= lr+nwe&%rc) FERC HOLE DIAMETER V ,1nn TE ST RUN BcT:IE_N Z FT AND_FT COf.MENTS 1 K S?`Y V �� Q 1 re' At PERFORNIED BY: MI h t- ) CERTIFY THAT THIS TES WAS/ PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: L ff[ 070 Municipality of Anchorage Page 1 of 2 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW990258 PID Number: 016-292-09 Name; KEN ZIEGAHN Wastewater System: ❑ New ■ Upgrade Address: 3321 PORCUPINE DRIVE ANCH. AK, 99516 ABSORPTION FIELD Phone: (907) 345-5770 No, of Bedrooms: 3 ❑ Deep Trench O Shallow Trench ■ Bed ❑ Mound 13 Other LEGAL DESCRIPTION Soil Rating: 0.7 Total Depth from original grade: *4.1 (MAX.) Ft GPD/Sq. FL Lot: Block: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 138 - - 1.4 (MAX.) Ft. 0.55' FL Township: 12N Range: 3W Section: 33 Fill added above *& original grade: Gravel length: VARIES FL 45 Ft. WELL: Grovel wIdthi 15 Number of Knee: Distance between lines: 1 ❑ New ❑ Upgrade FL 3 5 Ft. Classification (Private, AB,C): Total De Goes d To: Total absorption area: Pipe--ledal: 1,25" HDPE/ASTM Ft Ft. 675 S0. Ft. I D-3034/F-810/SCH 40 PVC Griller. Date Drilled: Static Water level: Installer. WOOD AND SONS Date Inela led: 93/99 — 9/11/99 Fl Yield: Pump Set At: Casing Height Above Ground: TANK GPM FL FL SEPARATION DISTANCES o Septic ❑ Holding ■ S.T.E.P. To Septic Absorption Lift Holding Public/Private Manufacturer. ANCHORAGE TANK Capacity In gallons: 1250 From Tank Field Station Tank sewer Lines Well 100'+ 100'+ 100'+ — 25'+ Material: STEEL Number of compartment.: 2 SurfacWater 100'+ 100'+ 100'+ - - LIFT STATION Water Line 10'+ 5'+ — — Size in gallons: 1250 Manufacturer. ANCHORAGE TANK 5'+ 'Pump on' level at: Pump off level at-Hlgh walsr alarm al: Foundation 5'+ 10'+ 5'+ — — 4.2" 42" 44" Curtain Pump Make 8 Model: Electrical Inspections performed by: Drain NONE KNOWN - #20 DSI OS HI F M.O.A. BENCH MARK Remarks: * 2.1 FEET OF M.O.A. APPROVED SAND FILTER. Location and Description: ADDED ABOVE THIS DEPTH. TOP OF MANHOLE LID. ** SEE ATTACHED PROFILE DRAWING. Assumed Elevation 97.76 R. ENGINEER'S SEAL oo6�>OOD . o • .�r�pp AWWC INC. Inspections performed by: Dates: 1st 9/9/99 •� . *• • • ••• • • ••••••• •••�`• 0� 2nd 9/11/99 D 3rd 9/15/990 r A. Ga ess- O�pp�m� Department of Health and Human Services approval ••• —7953 : (!s Reviewed and approved by WZr / W P&--f-Date:('-0 0 4�o0(71 1essionD, 0pO0���0 72-013 Rev. 9/91) Mao 25 I PERMIT NUMBER: A S —BUILT DRAWING PARCEL ID NUMBER: SW990258 .018-292-09 PI SP PANIC — 0,55 I or 17Rm 91,0W PIPE "-PINK GRN9E -100,48 -100,82 PoffOM OP 912 -� - 9535 for OF fANK AfIW-92t ORIGINN-GRA17E- 99,42 (NICJf5f POND 96.99 (6O95f POW) �- PII.iERPADRIC fop OP 5AN7 - 97,45 INVERT OP PIPE - 98,0 (AVG.) Ca;x 1 for OP MA6N - 99,96 STOP OF fMK /Af OIIILEf - 92,59 NEW 1250 6LON TANK kr or nuvG AT OUILEf - 91,84 ALASKA WATER AND WASTEWATER CONSULTANTS, INC 6901 DEBARR ROAD, SUITE 28. ANCHORAGE, AK. 99504 PHONE: (907) 337-6179/FAX: (907) 338-3246 3AL DESCRIPTION: T12N, R3W, SEC 33; LOT 138 IE OF WORK: AS—BUILT OF SEPTIC SYSTEM UPGRADE EPARED FOR: PHONE NUMBER: KEN ZIEGAHN (907) 345-5770 TE: DRAWN BY: SCALE: PAGE: 10/12/99 K.D.W. 1 = 40' 2 OF 2 0 A. Carnes Permit Number: SWO90258 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Aug 06, 1999 Expiration Date: Aug 05, 2000 Parcel ID: 018-292-09 Legal Description: T12N R3W SEC 33 LT 138 Design Engineer: 0041 AK Water & Wastewater Consulta Site Address: Owner Name: Ken Ziegahn Lot Size: 108900 SQ. FT. Owner Address: 3321 Porcupine Trail Total Bedrooms: 3 Permit Bedrooms: 3 Anchorage , AK 99516-3964 This permit is for the construction of: Z Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: �0 Issued By: Date: Alaska Water & Wastewater Consultants, Inc. 6901 DeBarr Road, Suite 213 — Anchorage, AK — 99504 (907) 337-6179 — Fax (907) 338-3246 Consulting Engineers August 3, 1999 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Sewer Upgrade for Township 12N, Range 3W, Section 33, Lot 138 To whom it may concern: The existing 3 bedroom house is served by a private septic system and a private well. The existing drainfield is completely surcharged and surfacing effluent. An upgrade is needed immediately. Three test holes were excavated on the property and the soils are summarized as follows: 1. SOILS: Test hole #1 was excavated to a depth of 7.5 feet and groundwater was encountered at 7 feet below grade. One week later groundwater was found to be 5.5 feet below grade. There was approximately 2 feet of organics followed by ML and SM material to a depth of 4.5 feet. From 4.5 feet to the bottom of the test hole was a GW to GW - GM material. One perk test was performed at a depth of 3.5 feet and perked at a rate of 36.9 minutes/inch. Test hole #2 had a total depth of 6.5 feet and groundwater was encountered at 6.25 feet. No groundwater monitoring tube was installed. Below the initial 6" of organics to a depth of 5 feet below grade was ML and SM material similar to what was encountered in test hole #1. From 5' to the bottom of the test hole was a GW material. One perk test was performed at a depth of 2.5 feet and perked at a rate of 7.5 minutes/inch. Test hole #3 was excavated to a depth of 9' and groundwater was encountered at 8 feet. One week later groundwater was at 6.3 feet below grade. From the top of the test hole to a depth of 3 - 3.5 feet was organics and loam with a large amount of roots from surrounding trees. Below the organics to the bottom of the test hole was a GW material that perked at a rate of <1 minute/inch. A sand filter will be required. 2. BED DESIGN: The proposed bed design is to be based upon the soils encountered in test hole #3. a. Percolation Rate: 36.9, 7.5, <1 minutes/inch b. Application Rate: 0.7 gallons/day/ft2 c. Number of Bedrooms: 3 d. Design Flow: 450 gallons per day e. Minimum Absorption Area: 643 ft2 I. Total depth: 3.5 feet g. Effective Depth: 0.5 feet h. Reduction Factor = N/A i. Width: 15 feet j. Length: 45 feet k. Sand Filter: 2 feet 1. Effective absorption area = 675 ft2 (643 ft2+) 3. SURFACE WATERS: Rabbit Creek flows through the west end of the lot. The proposed septic upgrade will be well over 100 feet from the creek. 4. TOPOGRAPHY: The area where the proposed septic is to go is virtually level and at the bottom of a bluff. In short, there are no slope concerns. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact me at 337-6179, or 244-9612. Thank you for your assistance. n Sincerely .E., M.S. LOT 118 LOT 119 LOT 120 T12N, R3W, SEC 33 T12N, R3W, SEC 33 T12N, R3W, SEC 33 PORCUPINE TRAIL ---- _ PROPOSED SEPTIC SYSTEM / (SEE DESIGN, PAGE 2 OF 3) / NORTH DAVIDSON PARK i 'p TH#3 // 137 / T12N, R3W, SEC 33 WELL HOUSE ) I O / EXISTING SEPTIC SYSTEM /F v� \ �+ H/ EXISTING 3 BEDROOM BOE pQ0 MOBILE HOME TH#2+ M I w 0) N I .- M O� LOT 172 T12N, R3W, SEC 33 LOT 152 T12N, R3W, SEC 33 I LOT 153A T12N, R3W, SEC 33 n t= ( ALASKA WATER AND WASTEWATER CONSULTANTS, INC. 006000 6901 DEBARR ROAD, SUITE 2B. ANCHORAGE, AK. 99504 o PHONE: (907) 337-6179/FAX: (907) 338-3246 QQ� •.i �oo • '•]' LEGAL DESCRIPTION: : TOWNSHIP 12N, RANGE 3W, SECTION 33, LOT 138*?„*.. TYPE OF WORK: SITE PLAN '• e fir A.. •..... AO '• —7953 •' iQO ' PREPARED FOR: PHONE NUMBER: KEN ZIEGAHN (907) 345-5770 0 Vo • Ns, 44�@~ed SCALE: PAGE: DATE: 8/3/99 DRAWN BY: A.C.G. 1 = 100 1 OF 3 Professlo�'oogo ��OO000�o �W G /I/- / PROPOSED SEPTIC BED— (SEE DETAIL, PAGE 3 OF 3) i Qf D \ �W G /I/- / PROPOSED SEPTIC BED— (SEE DETAIL, PAGE 3 OF 3) �kiSnNG M�0MFGDM / TH#+ / / / / TH#2� / / AO I / / / / PROPOSED / S.T.E STING 1000 GALLON TANK TO BE PUMPED, JSHED, AND BURIED. �� V 0 O� AO e i ALASKA WATER AND WASTEWATER CONSULTANTS, INC. 6901 DEBARR ROAD, SUITE 28. ANCHORAGE, AK. 99504 PHONE: (907) 337-6179/FAX: (907) 338-3246 LEGAL DESCRIPTION: TOWNSHIP 12N, RANGE 3W, SECTION 33, LOT 138 TYPE OF WORK: DESIGN OF SEPTIC SYSTEM UPGRADE KEN ZIEGAHN (907) 345-5770 8/3/99 I A.C.G. I 1= 40' I 2 OF 3 F'169i�!�P: 50 GALLON TANK H . �*I A. GOrness;' E-7953 a}� p4 ..... W �:rer c(`�'c�d Qf D \ �kiSnNG M�0MFGDM / TH#+ / / / / TH#2� / / AO I / / / / PROPOSED / S.T.E STING 1000 GALLON TANK TO BE PUMPED, JSHED, AND BURIED. �� V 0 O� AO e i ALASKA WATER AND WASTEWATER CONSULTANTS, INC. 6901 DEBARR ROAD, SUITE 28. ANCHORAGE, AK. 99504 PHONE: (907) 337-6179/FAX: (907) 338-3246 LEGAL DESCRIPTION: TOWNSHIP 12N, RANGE 3W, SECTION 33, LOT 138 TYPE OF WORK: DESIGN OF SEPTIC SYSTEM UPGRADE KEN ZIEGAHN (907) 345-5770 8/3/99 I A.C.G. I 1= 40' I 2 OF 3 F'169i�!�P: 50 GALLON TANK H . �*I A. GOrness;' E-7953 a}� p4 ..... W �:rer c(`�'c�d PIAN VEW I Mf r-------- -------------_ I O I N I I � I I I y� � I O L-------- MT---------- PROP05E1 PIT55RIZE16EP; 45' LONG DY 15' W1 6Y 35' PEEP. APP 2'9 M.O,A APPROVED 5ANP FILTER MATERIAL ANP 6" OF CLEAN, WA51dW SEWER DRANROCK, ORIGINAL GmA Pp'OFL� VEW Mf i 6" OF PRANROCK T 6ENEA1N PIPE i 5' 1,25" 0 PIPES WITH V 16" 01 HOLES @ 4' O.C, 33 HOLES Tc—/r& FINAL 61W1 ( 2' MINIMUM COVER) IN%LATION (IF COVER 151.E55 THAN 3 FEET) 5ANP Fl�lEl� Mf 4' MINIMUM TO 20UNPWATER I ALASKA WATER AND WASTEWATER CONSULTANTS, INC. 006000 6901 DEBARR ROAD, SUITE 28. ANCHORAGE, AK. 99504 PHONE: (907) 337-6179/FAX: (907) 338-3246 a4 .•'•• •.S�Oo GAL DESCRIPTION: Q Q •,-�' TOWNSHIP 12N, RANGE 3W, SECTION 33, LOT 138 * :„ ,•,;;,*, ..... PE OF WORK: PLAN AND PROFILE OF PROPOSED BED • ......••• J f e A, rness; IEPARED FOR: PHONE NUMBER: QO P •�( i 9 KEN ZIEGAHN (907) 345-5770 09s E-753 ,• `�G 411 Fer ••''••.......•' 8/3/99 A.C.G. I N.T.S. 30F3 �ALASKA WATER & WASTEWATER CONSULT I SOIL LOG - PERCOLATION TEST LEGAL DESCRIPTION: TOWNSHIP 12N, RANGE 3W, SECTION 33, LOT 138 PERFORMED FOR: KEN 7|EGAHN DATE PERFORMED: 7/21/99 QEPT �ITEST HOLE ^�'~ (l[7(�/\N|(�'�/ 1 v/�omnuu/ LOAM 2— DATE GROUNDWATER SOIL CLASSIFICATIONS 7/23/99 8RG G 3—ML3— ML &" SM GP ML GM CL 4— G C 8L SW MH 5 ------- SP CH GW TO SM UH 6 SC 7 9 10 11 12 13 14 15 10 17" 19 ��__ COMMENTS: DEPTH TO DATE GROUNDWATER WATER LEVEL READING NET DROP (INCHES) 7/23/99 PERC. HOL--- WAS PRESOWED 4+ HOURS DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 7/23/99 PERC. HOL--- WAS PRESOWED 4+ HOURS PRIOR TO TESTING ------- PERCOLATIONRATE J69(MIN./INCH) PERC.HOLE DIA. O (INCHES) TEST RUN BETWEEN 3.5 FT. AND FT. | PERFORMED BY ALASKA WATER & WASTEWATER |, THIS WAS PERFORMED IN /ACCORDANCE \N|THALL |C| . CERTIFY T IN EFFECT ON THIS ALASKA WA ,TANTS, INC. SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: TOWNSHIP 12N, RANGE 3W, SECTION 33, LOT 138 PERFORMED FOR: KEN ZIEGAHN DATE PERFORMED: 7/21/99 DEPTH ; (feet) .: ORGANICS ITEST HOLE #2 1- 2- SOIL CLASSIFICATIONS ML & SM '_o-> GW ORG 3— � GM _� CL 4�/ GC IFFA, OL po o o SW MH d�"� fl� I� CH 5 - °<�,"r SP o GW z sc 1' off 7 8 9 10 11 12 13 14 15- 16- 17- 18- 19- 20 51617161920 COMMENTS: DEPTH TO DATE GROUNDWATER 6.25' 7/21/99 TH/3+ DATE READING CLOCK TIME NET TIME (MINUTES) WATER LEVEL READING NET DROP (INCHES) 7/23/99 PERC. HOL WAS PRESO KED 4+ HO RS PRIOR TO TE TING 1 3:14- 2 3.44 30 1 15/16" 4 1/16" - ------3-- -- 3:44 —_ --- 6„ 4 4:14 30 2 4" 5 4:14 — 6" - -- -6 -- 6 -- --- -- 4:44 ---- - 30 -- -- - - - 2" - — 4" PERCOLATION RATE 7.5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 2.5 FT /SND 3 FT. MONITORING TUBE WAS INSTALL II /lll / PERFORMED BY ALASKA WATER & WASTEWATER I, THIS WAS PERFORME ACCORDANCE WITH ALL DATE. DATE: r , CERTIFY THAT NES IN EFFECT ON THIS .TER & WASTEWATER CONSULT SOIL LOG — PERCOLATION TEST LEGAL DESCRIPTION: TOWNSHIP 12N, RANGE 3W, SECTION 33, LOT 138 PERFORMED FOR: KEN ZIEGAHN DATE PERFORMED: 7/21/99 DEPTH r; TEST HOLE #3 (feet) ORGANICS 1 & LOAM 777 2 W/ EXTENSIVE SOIL CLASSIFICATIONS 3 4 5 6 7 8 9 10 11 12 13 14 15- 16- 17— is- 19- 20-- COMMENTS: 51617181920COMMENTS: ROOT SYSTEM FROM TREESGW ORG GP _. ML GM j CL GC [; OL SW [ j MH o Uro o ° ma _ SP 1 CH < GW f SM .' OH 9 r Sc DEPTH TO DATE GROUNDWATER 8' 7/21/99 6.3' �7/28/99 THN3+ PERCOLATION RATE <1 (MIN./INCH) TEST RUN BETWEEN 3.5 FT. AND PERFORMED BY ALASKA WATER & WASTEWATER I, THIS WAS PERF f2 ED IN ACCORDANCE WITH ALL DATE. DATE: . HOLE DIA. 6 (INCHES) FT. , CERTIFY T ES IN EFFECT ON THIS GRED :R ANCHORAGE AREA BOP ,IGH Department of Environment Quality �Iftl 3500 Tudor Road Anchorage, Alaska 99507 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME J)AI//-- )-JAM MAILING ADDRESS;70 6� 10 01- 12 S` PHONE LOCATION LS4!W OF PDrCU Pi.yc 'j�!A EGAL DESCRIPTION ✓-'�)o0i /P.S� SEPTIC TANK: DISTANCE lJ>11iNv✓�111_ NUMBER OF FROM WELL MANUFACTURER - MATERIAL COMPARTMENTS INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY aOOGALLONS. TILE DRAIN FIELD: TOTAL LENGTH DISTANCE FROM WELL —FOUNDATION—NEAREST LOT LINE �-O '�zz/_OF LINES QS/ r NUMBER OF LINES �— DISTANCE BETWEEN LINES %O -_ TRENCH WIDTHJ4 IN. TOTAL EFFECTIVE ABSORPTION AREA `S 3 SQ. FT. LENGTH OF EACH LINE O' 31J_/ - 3 �" �` ,? �� ':� - 70 ' /42 z DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE G/ MATERIAL BENEATH TILE !O IN. ABOVE TILE <'�- IN. WELL:: TYPE —CONSTRUCTION BUILDING NEAREST FOUNDATION LOT LINE CESSPOOL ----OTHER SOURCES (NEAREST SEPTIC SEEPAG SEWER LINE , TANK , SYSTEM APPROVED ' DISAPPROVED REMARKS DISTANCES: • S �f �'/N /t/ INSTALLED BY: 4 e2y_ le,4ti7' SEWER LINE DEPTH: PIPE MATERIAL: LOT SLOPE: Lyd/E/, REMA✓iRKSVU S ' /J"& 0 AiNV6'c/ z) '7o 096 QTc/ Form PW -027 DIAGRAM OF SYSTEM DATE q --1%'%,S APPROVED / G.A.A.B. E FROM: TANK bP f o GL!✓dVO./i o., GREATER ANCHORAGE AREA BOROUGH • °q DEPARTMENT OF ENVIRONMENTAL QUALITY ,\\,\v\'A_N PERMIT NO.. 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM ® APPLICATION ANIS PERMIT NAME OF APPLICANT 1� r/�✓ MAILING ADDRESS ' `y PHONE INSTALLATION LOCATION LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK v SEEPA`GEi'Ii`-`---, DRAIN FIELD L� OTHER TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS % !�//�� COMPLETION DATE ANTICIPATED At TO BE INSTALLED BY Se�' j NOTE: THIS IT IS NO'Y VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK / FOUNDATION TO SEEPAGE PIT DRAIN /�I, DRAIN FIELD / SEPTIC TANK TO SEEPAGE PIT WALL --/S o/ SEPTIC TANK SEEPAGE PIT � DRAIN FIELD %y /IA%1Cle 7Ir eNch 2 AREA SIZE TYPE/ / Pp d1/ DIAGRAM OF SYSTEMr,nC,-�cS-� TO NEAREST LOT LINE. WELL TO SEPTIC TANK F%O SEEPAGE PIT /00 DRAIN FIELD —__ ---, ALSO CONSIDER AREA WELLS. r WATER MAIN TO SEPTIC TANK /Q SEEPAGE PIT /O / DRAIN FIELD SEPTIC TANK, < �O / SEEPAGE PIT DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL 13ACKFILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. cl G.A.A.B. OR LICENSED DESIGNER ■ ■ i d■■�■■■■■■■ I ■■■ IN■ IS IN mul� ■im■■■ ■■■ ■■■■■ ammmimmom ONNO iiia Nil ��■■�■©Imm INf.'i C... �fZIPrJ►.■ilra�m� ■ ■ ■ ■ll■ .� ■I�C�■a . [Es4i�C3i� ■ .�.� ■CI ■ Nil ■■■■il iii■i��■iiii■■E�a� II�f1��fii;��■ ■■1i■■ �iiiii IN IN IS ■t■■■■ i■ ■ C ::_���IM ■■11■C11■■ IN NINON ■ ■■■ 1100■ IN ■�I�ISO ■I�� Its :::�::�::_IN:: ■■■■■� IJI■■■ NMI 8�!`,,ml,IMMFA■II■■ ■■ a Ki■■■■II■■ IN■■■II■■ IN CC NN I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 2868 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATEi/�// APPLICANT'S SIGN TURE FORM NO: EO -016 GREATER ANCHORAGE AREA BOROUGH DEPARTMENT OP- ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 90503 I�I��I ��II ✓uu///)///) f TEL EPt10 NE 274-4561 SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT NAME OF APPLICANT INSTALLATION LOCAT LEGAL DESCRIPTION PERMIT NO. ADDRESS s �Il'u _"�"N5� 5-- PHONE S �3 ��7� INSTALLATION OF: SEPTIC TANK _ - SEEPAGE PIT -- TYPE AND SIZE OF FACILITY TO BE SERVED - - NN_ -rte DRAIN MELD OTHER FINANCED THROUGH _ -I'D BE INSTALLED BY SOIL TEST RESULTS � �_ ' NOTE, THIS PERMIT IV, NOT VALID WIT14OUT SOIL. TEST COMPLETION DATE ANTICIPATED FINAL INSPE CYTON: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OP ]ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSE'CU'TION. SEPTIC TANK SIZE __ – TYPE _ SEEPAGE AREA SIZE __--.._— TYPE MINIMUM DISTANCES, REOUIRE:MENTS FOUNDATION TO SEPTIC TANK C FOUNDATION TO SEEPAGE PIT _��� DRAIN FIELD 1 SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK _ ' I . SEEPAGE PIT c)<�', r , DRAIN FIELD TO NEAREST LOT LINE. ' xxO� WELL TO SEPTIC: TANK )Qy ,SEEPAGE PIT DRAIN FIELD _ I Cio I ALSO CONSIDER AREA WELLS, WATER MAIN TO SEPT)C TANK —. SEEPAGE PIT /() DRAIN FIFI..D 10 SEPTIC TANK. -Lo-q/. SEEPAGE PIT I oc) DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WI'-FAGki'REMOVA BLE CAPS. GRAVEL ®ACKFIL_L CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. G.A.A.S. OR LICENSED DESIGNER DIAGRAM OF SYSTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 2868 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. i DATE ` �� �� APPLICANT'S SIGNA u TURE FORM NO. EQ -016 G� ,..� iaS•,h`rA FINC! Civil Fngincers JAMES W. ROONFY, P. E. MALCOL.M A. MENZIES, P.E., L.S. JAMES H. WELLMAN, P.E. August. 2.2, 1973 229 LAST 51st AVE. —P.C. FOX 6087 -- ANCHORAGE_ AI ASKA 09b03 TELEPHONE 907--279-0483 TELEX f X 000 -35479 Mr. Dave Hamner 705 Muldoon Road Space #5 Anchorage, Alaska Geologists R & M No. 36652 lAinOlh viol) p.06 a .')1g/'3 AM UPp,tni ER ANCHdpr\GE„Ni^ 0421 i1” pF.Pt, of erivi ���; Re: Test- Role and Soil Log Report for Sanitary System, Lot 138, Section 33 T13NR3W S.M. Dear Mr. Hamner: We are submitting herewith the test boring results and our comments regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of August 20, 1973, and those procedures outlined in a letter dated September .13, 1971 by Mr.. Rolf Strickland of the Greater Anchorage Area Borough Department of: Environmental Quality. Land Surveyors RALPH H. MIGILAC010 EnginMMO OmMWst A single test hole was put down within the Lot 138 area for the purpose of defining general subsurface soi_l conditions for the pro- posed sanitary system. Excavation was accomplished witha tractor -- mounted backhoe and the test hole was extended to a total depth of 9 feet bal.ow ground surface. The .final log prepared for the test hole has been included in Drawing A-01. Ground water was encountered :in the test hole at a depth of 9.0 feet. We appreciate being given thLs oppurtu&Ly to be of service to you. Should you have any questions with regard to the above, please do not: hesitate to contact us. Very truly yours, R & 1-1 ENGINEERING & GEOLOGICAL CONSULTANTS James W. Rooney ` JUR: ph XC: CAAli t/ ANCHORAGE FAIRBANKS JUNFAU 9,0 9.0?.I>. -- ' )y01C: Test hole excavated wiLktzan�ozmouoto8backhoe natez onvouoioznJ n�. 9�0 tee�. DAVSjU\AIAIERPROPERTY ^ EnV|owmdnV��8�o|o�iuq|(�onoui�onio 1/}G.0f`'C6S7flOI,C ^ ^ � ,^. y^oxo /)��oa/^ �o*,^o �X --»«^m'«�~.'^»`.`-~-,^--~~--^-''~^-^~-~ /\�u��a -----~----`---------`------'--DY,N DAT MUNICIPALITY OF ANCHORAGE Development Services Department P p T Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I.D. 018-292-09 Legal description T12N R3W SEC 33 LT 138 Site address 3260 PORCUPINE TRAIL RD Expiration Date: 8/3/23 Current property owner(s) TROWBRIDGE DAVID B &MICHELLE E XThe On-site system(s) is/are approved for 7 bedrooms Conditional approval for Comments or advisories: bedrooms, with the following stipulations: Original Certificate Date: 5/3/22 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory Tank Age Advisory X Arsenic Advisory Other COSA ApprovM_June 2022 MUNICIPALITY OF ANCHORAGE Development Services Department r�`T Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Application 1. GENERAL INFORMATION Parcel I.D. 018-292-09 Complete legal description T12N R3W Sec. 33 Lot 138 Location (site address) 3260 Porcupine Trail Rd. Anchorage, AK Current property owner(s) David B. & Michelle E. Trowbridge Day phone 2. ON-SITE SYSTEMS SIZED FOR 7 BEDROOMS 3. TYPE OF WATER SUPPLY: © Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: © Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: V Steel ❑ Plastic ❑ Concrete ❑ Fiberglass Age 24/15* - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑ AWWTS © Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: *Note: 2 Steel tanks Expedited review requested: ❑ Distance: By applying for this entitlement, this property is subject to inspection by municipal On-site staff to verify the accuracy of the information provided. COSA Fee $ -550 Date of Payment ( Z X23 COSA # OsG 2:� 1 I OCl Waiver Fee $ Date of Payment Waiver # COSA Application—June 2022 Legal Description: COSA Checklist T12N R3W Sec 33 Lot 138 Parcel ID, _ 018-292-09 If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system A. WELL DATA ./❑ Well log is filed with Onsite (or attached) Date drilled UNK Total depth 36 ft Cased to 30+ ft © Sanitary seal is functioning correctly ❑1 Wires are properly protected Casing height (above ground) 30 in. Date of flow test for COSA 4/4/23 Static water level at beginning of test 26 ft. Comments B. TANK DATA Measured operating fluid level in septic tank 4211/49" Date of pumping 5/20/22 ❑ Required maintenance completed, if AWWTS Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) 1999/2005 ❑./ ALL standpipes present per record drawing Total measured depth from grade 5/4 ft (max) Measured depth to pipe invert from grade ft (min) ❑✓ N/A — pressurized field. ❑ Per record drawings, field is insulated. ✓❑ Monitor tubes go to bottom of effective. If not, state depth into effective ❑ Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies COSA Checklist June 2022 Well production at time of test 4.5+ gpm Water storage tank volume NA gallons Well disinfected for coliform test? ❑ Yes ✓❑ Nc 0 Coliform bacteria is Negative Nitrate 3.69 mg/L E:1Nitrate less than MRL (ND) Arsenic ug/L 0 Arsenic less than MRL (ND) Collected by Arcterra Consulting Date 4/3/23 C. LIFT STATION ✓❑ Required maintenance completed Age of lift station 24 years Lift station material Steel Comments: Adequacy test date 4/4/23 Results [0 Pass Fluid depth prior to test 0/2 in Water added 1050 gal New fluid depth 0/2 in Elapsed time 1 min Final fluid depth 0/2 in Absorption rate 1050+gpd FIELD STATUS — POST RECOVERY Effective depth (per record drawings) 6/6 in Effective depth used 0/2 in Effective depth remaining 6/4 in F E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' Yes if No 1 Septic Tank/Lift Station on Lot n 100' '• Tank to Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots* Community Sewer ManholefCleanout > 100' © Yes if No ft Water Service Line > 10' © Yes if No 0 Yes if No ft Neighboring Tank > 100' Yes if No It Private Sewer/Septic Line > 25' FZ] Yes if No ft Absorption Field on Lot > 100' © Yes if No ft Holding Tank > 100' 0 Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' 0 Yes if No ft Q Yes if No It Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ©Yes if No It Q Yes if No It ❑ NIA — Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10' Yes if No 1 ft Surface Water > 100' Yes if No ft '• Tank to Property Line > 5' 0 Yes if No ft Wells on Adjacent Lots* i Field to Property Line > 10' 0 Yes if No ft Private Wells > 100' •/ Yes if No ft Water Main > 10' Yes if No ft Community Wells > 200' Yes if N? ft Water Service Line > 10' © Yes if No ft If tank or field is under driveway comment below F. ENGINEER'S COMMENTS G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that rry ice, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes. ordinances, and regulations in effect at the time of instaNation, unless noted otherwise. Name of Firm Areterra Consulting Phone (907)-69" 111 Engineer's Printed Name Kenneth Duffus Date Y-//./ Engineer's Cnmmcum This lovestlgation was cotapleted in compliance with ADEC and MOA regulatiuns. The asussment of the ruedilion of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may ehans due to subsurihm conditions that may not be observed from tie surface, rhanuvs inland use, local soil characteristics graumrwater levels that may fluctuate during the year and the water usage or the family hcing served by the system. The operational life of all well and septic systems are subject to these various and dynamic duwartcristics and are outu& the control of the evaluator of the well and septic acstrw. Therefore, ArcTerra can sot Sive any estimate of how long a system will function satisfactory- for current or future occupants or can ArcTerra guarau!that Be unseen encroachments, deficiencies or discrepancies exist COSA Che&W Jute 2022 Septic Tank Advisory Certificate of On -Site Systems Approval # OSC231109 Subdivision: T12N R3W SEC 33 Block: , Lot: 138 The septic tank for this property is 24 years old. The average life of an asphalt coated steel septic tank is 20 years. Typical replacement costs are $10,000 or more, not including engineering, surveying or MOA permitting fees. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 30 year old steel tank MAY look like. i :Mailing Address P O�Box 196650 *Anchorage, Alaska 99519 6650 *www muni org L MUNICIPALITY OF ANCHORAGE Development Services Department _ Phone: 907-343-7904 On -Site Water &Wastewater Section Fax: 907-343-7997 Lift Station/Pump Vault Maintenance Log Owner T C" Street AddressMLD Septic Tank: -Sludge level I k inches ,Pumping: required es no -Pumping completed yes no Lift station: -Pump basket cleaned no -Effluent filter cleaned es no *Control floats cleaned s no . *Proper float settings confirmedes no - -Operation satisfactory es no Alarm System: -Dedicated electrical alarm circuit as no -Audible and visual alarm inside dwelling es no -Alarm system operation satisfacto not satisfacto Manhole Riser -Ground water intrusion at riser to tank connection as no -Ground water intrusion around pipe penetrations jes o -Weep hole functional es no -Manhole lid: Functional es no Insulated es na Properly Secured es no Other -All manufacturer required inspections and maintenance completed yes no Comments: Qualified Maintenance Provider: Technician Date of maintenance Company � C,S� �� � Signature - Date P,1 (- 3 MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section - Fax: 907-343-7997 Parcel I.D. 018-292-09 Certificate of On -Site Systems Approval Expiration Date: " Ig-2d� 1. GENERAL INFORMATION Complete legal description T1 2N R3W SEC 33 LT 138 Location (site address) 3260 PORCUPINE TRAIL RD ANCH, AK Current property owner(s) PHILLIP CALHOUN Day phone Mailing address Real estate agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 7 4. TYPE OF WATER SUPPLY: TYPE OF WAS G Q�TE,2ISP0: Private Well 0 Private S X o �, Water Storage ❑ Holding Community Well ❑ Commu I [OAR P(UZU Public Water System ❑ Public S r ❑ Waiver request for: 6 gisitaB Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 030 Date of Payment 3Jl& [Xd-U /� Receipt Number l ,Ls- 11g66 COSA# Os CAOIUgO Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On-Site staff may visit the site to verify the information submitted. Name of Firm MIKE N ANDERSON, P.E. Phone 727-8864 Address 4661 NATRONA AVE ANCH AK Engineer's Printed Name MIKE N ANDERSON, P.E. Date 3-15-20 ° 6. DSD SIGNATURE ` f.t i j gf'o 0 0 0 0 ®n o a u q.o e o 0 0 0 0 0 v fj 6�J � System #1 Approved for 7 bedrooms ° ° ° ° °. _ ¢ ° ° a ° ° ° .. h1I HAEL N. ANDERSON System #2 Approved for bedrooms t,% °, CE - 9zr69 $. ?0®e4 ti Disapproved Prti1_ C a it i Conditional approval for bedrooms, with the following stipul Original Certificate Date: 3 —/ C( --20 ?_b The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other—Tat..'k ! COSA Checklist blue sheet COSA Checklist Legal Description: T12N R3W SEC 33 LT 138 Parcel ID: 018-292-09 If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA Adequacy test date 3/5/20 Al Well log is filed with Onsite (or attached) Well production at time of test 5+ gpm Date drilled UN Water storage tank volume 0 gallons Total depth 36* ft Well disinfected for coliform test? ElYes RE N Cased to 36* ft Al Coliform bacteria is Negative A-1 Sanitary seal is functioning correctly Nitrate 2.62 mg/L A-1 Nitrate less than MRL (ND) X Wires are properly protected Arsenic ug/L FO -1 Arsenic less than MRL (ND) Casing height (above ground) 30"+ in. Collected by MNA Date of flow test for COSA 3/5/20 Date of Sample 3/5/20 Static water level at beginning of test 10 ft. Absorption rate 1050 gpd Comments * SEE ARROW PUMP INSPECTION, 3/16/05 IN THE MOA FILE B. TANK DATA Age of tank(s) 12/21 years Tank type/material STEEL Measured operating fluid level in septic tank 8 A] Standpipes/foundation cleanout per record drawing Date of pumping AROUND THE CLOCK PUMPING 3-1 —2.020 D. ABSORPTION FIELD DATA 2 FIELDS W/ VALVE C. LIFT STATION X Required maintenance completed Age of lift station 21 years Lift station material STEEL Comments: MAINTENANCE CHECK DONE BY LARRY BETTS, L&S SERVICES. Which system tested (date installed) 99105 Adequacy test date 3/5/20 ❑Q ALL standpipes present per record drawing Results ❑✓ Pass For 7 bedrooms Total measured depth from grade 2.5 ft (max) Fluid depth prior to test 0 in Measured depth to pipe invert from grade 3.0 ft (min) Water added 1050 gal ❑ N/A — pressurized field 1 New depth in ❑E Monitor tubes go to bottom of effective. If not, state Elapsed time 1440 min depth into effective O Code -required soil cover over field Final fluid depth 0 in ❑ System presoaked Absorption rate 1050 gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) UN date of test) Gallons introduced 0 gallons If yes, enter date Comments/Deficiencies: NORTH BED WAS TESTED, SOUTH BED HAD 4" OF WATER, VALVE TURNED TO NORTH BED COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' P1 Yes Community Sewer Manhole/Cleanout > 100' El if No ft Q✓ Yes if No ft Neighboring Tank > 100' ❑✓ Yes if No ft Private Sewer/Septic Line > 25' 0✓ Yes if No ft Absorption Field on Lot > 100' ❑✓ Yes if No ft Holding Tank > 100' F✓ Yes if No ft Neighboring Absorption Fields > 100' Yes if No Animal Containment > 50' F/ Yes if No ft M✓ Yes if No ft if No ft F. ENGINEER'S COMMENTS Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' ✓0 Yes if No ft 0✓ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ✓❑ Yes if No ft Surface Water > 100' E✓ Yes if No ft Property Line > 5' P1 Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' Q✓ Yes if No ft Private Wells > 100' ✓0 Yes if No _ Water Main > 10'✓❑ ✓0 Yes if No ft Community Wells > 200' ✓� Yes if No _ Water Service Line > 10' Q✓ Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' ✓l Yes if No ft If absorption field is under driveway comment below Property Line > 10'✓� Yes if No ft Wells on Adjacent Lots: Water Main > 10' ✓0 Yes if No ft Private Wells > 100' Yes if No Water Service Line > 10' ❑✓ Yes if No ft Community Wells > 200' Yes if No Surface Water > 100'✓Q Yes if No ft F. ENGINEER'S COMMENTS ft ft ft ft G. ENGINEER'S CERTIFICATION I certify that l have determined through field inspections and review d �`P of Municipal records that the above systems are in conformance with ` ° 41 QT ; MOA COSA guidelines in effect on this date. A ,t.. p ffi � p b C+ L' • b y 0 p 6 a ffi 6 A M �Y E,j VUCH' cH N. ANDCRSOi! f V to CE -0469 COSA Checklist yellow sheet ft ft ft ft MUNICIPALITY OF ANCHORAGE Development Services DepartmentPhone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Lift Station/Pump Vault Owner P�l t ca'l Lz"Vl Street Address 3 � 6_Pn CC v pN o o 'T �J Phone 3(9_ Legal Desc. PID OL y -- zI 2-0 Septic Tank: L3 -Sludge level inches -Pumping: required yes no...:`°Pumping completed (jj) no Lift station: -Pump basket cleaned es n � ''� -Effluent filter:c(eaned ' es : no f dct 1. , -Control floats cleaned (@ ___no -Proper float."" ttings confirmed: es no -Operation satisfactory es no Alarm System: -Dedicated electrical alarm circuit es'<rio::_ •Audibld'andwisual alarm inside"dwelling es no -Alarm system operation isfacto :satisfactory or Manhole Riser -Ground water intrusion at riser to 6nk connection es:`:rio: ; . -Ground water intrusion are:find pipe'pe'netratioris ; `.es no < •Weep hole functiona{ es no -Manhole lid: Functional es:. no ,:;:;:.::. Insulate d`::;: es no Properly Secure es no Other -All manufacturer required inspections:;and maintenance completed es no Comments: 0. l d; .... 1.. 2 t�...................................................... -Jyw✓\ ((/teJ C/W9 i`f> � l{ S �� �un�h� VOal Oma c .................... ............ .,.... . ............................................................................................................................................................... Maintenance Provider: Technician Agg Date of maintenancell Mk(- 0 Company L-- -S Signature Date MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT On -Site Water and Wastewater Section www.muni.org/onsite Septic Tank Advisory Certificate of On -Site Systems Approval #OSC201090 Subdivision: T12N R3W Sec33 lot 138 907-343-7904 Fax: 343-7997 Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for this property is 21 years old. Typical replacement costs range from $8,000 to $11,000. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 20 year old steel tank MAY look like. Municipality of Anchorage Development Services Department Building Safety Division ' _ On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519.6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 0( ^212-0 C COSA# 0Ro rn'I Expiration Date: - r� 1. GENERAL INFORMATION I, Complete legal description T/2/d 3� /i czfrov, Location (site address)eT0;, p� e, 11t Current Property owner(s) 1'n r 11t ,R t''a �uu n _ Day phone 3 4G - "5 y 115'- SMailing Mailingaddress Lending agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site E6 Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Nf (r k rx I N /Ar, d T i sv n Phone _ 3 q 4 - 3"3 9 7 Address 14 t -i Ma4ry.n1 A .4.... :- Engineer's Printed Name N1«L max/ KI get Date YIrrlo �1E OF l��l i*•'%19TH=: ••*�� 5. DSD SIGNATURE 1 ;. MICHAEL N. 46DERSCY L/A roved for I+��gF`•ce. 9469 pp bedrooms. lik1 pRoirss"Mit��� Disapproved. Conditional approval for bedrooms, with the following stipulations: ii PiY fD In, »v►Ya e, 7e:_ 'It -A/.( 07T�i-_,u ;— nY A 6's e n i f,. r!s' ei61-c Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: ovl Original Certificate Date: 9 — " (R•. iimi) 'Municipality, of Anchorage Development Services Department !. Building Safety Division On -Site Water &Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: T /2^t R.3 to se, 3,,5 L 0,- I9 ParcelID: 0 tY- 7-1-L- Ott A. WELL DATA Well typet++ < <- row e W _ Date completed lin"Ili0 Sanitary seal (YIN) y Total depth Mp"itwm" Cased to 20 Aei ., ti -Cei X1r_J Log *�_ OT, WELL LOG Date of test / �f Static water levet c ft. 0 Well production 9 P.M. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate �. ( mg/L��)) senic: ug1L date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material -Si a._( Tank size 12- gal. Number of Compartments Well Log (Y/N) I d — Wires properly protected (Y/N)_ Casing height (above ground) '? 'Y n. AT INSPECTION Y 6/01) /0 ft. S { g.p.m. t` 661 I. O s c� s t 3• -e . ,A> 'f Other bacteria colonies///1010 mL Collected by: X05 (P(1 4 ti a,Jlo t - Date installed7 /-5 Zo :;2-_ Cleanouts(Y/N) Foundation cleanout (Y/N) Y Depression over tank (Y/N) _LL /High water alarm (Y/N) Y Date of pumping 7 0 & W/1� / Pumper A n c� o v. d 4 w< <i o r t -r -- C. ABSORPTION FIELD DATA Date installed t7 , Soil rating (g.p.d./ftZ or felbdrm) _6,0__ System type fSe9 i Length L 0 ft. Width Gravel below pipe t z ft. i Total depth Z.5 . ft. Eff. absorption area q00 fe Monitoring tube __ Depression over field Date of adequacy test O e Results (Pass/Fait) Ce 55 For bedrooms Fluid depth in absorption field before test J�_ in. Water addedL°Ogal. New depth in. Elapsed Time: �±- n. y �+ y Final fluid depth 4 in. Absorption rate >= f -Z ov g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date Act D. LIFT STATION / rzSo i-I2So Date installed Size in gallons 40E•► Manhole/Access (Y/N) 1� •Pump on' level at _ in. 'Pump off" level at _ in. Datum (3�of4o,, ,,f dor 6E_ Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot f 00 Absorption field on lot /00 • Public sewer main 11 1140 Sewer /septic service line Z S 0 Animal containment areas /010 High water alarm level at in. Meets alarm & circuit requirements? On adjacent lots 1oa On adjacent lots 100 Public sewer manhole/cleanout Fr /At, Holding tank 1 / b . Manure/animal excrete storage areas foo t— SEPARATION DISTANCES FROM SEPTIC/H0=NG TANK ON LOT TO: Building foundation ? 0 % Property line SO •� Absorption field SO �- Water main it A% Water service line 50 r f Surface water /V O r f Wells on adjacent lots I or) It SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 4;y 4- Building foundation Z 0 'f Water main . Water Service line 1010 1-- Surface water / u D r Driveway, parking/vehicle storage Z 0 r Curtain drain NlA' Wells on adjacent lots /L90 r f F. COMMENTS G. ENGINEER'S CERTIFICATION • S r ': / 1 certify that I have determined through field inspections and �,:44 9TH ; �; review of Municipal records that the above systems are in �. .. conformance with MOA COSA guidelines in effect on this date. yS-MICHAEL'N'AKbERSCN Engineer's Printed Name %�(I �G•r� /�� „ [ic,(,ef � ✓j .• •Vic,; Date Y�ff�o Y 1ll�FOPROTE ••....•0`_: � COSA Fee $ 5:7' 6D Date of Payment VOL g Receipt Number (Rev. 11/05) - Waiver Fee $ Date of Payment Receipt Number LO 03 CL in LO r - to b 00 Z N 00-08'18" W 330.40' (PER PLAT 85-26) M a Z., a: ' N O S 00'11'46" E - 330.59' (COMP PER PLAT 85-26) rn Tr --roc ., W 0 m 0 :� :JoZ QF -0 :m Ln F - (D LO co it 000 z CL D a) 12 04 0 U M C14 Lo zm 4-1 4" te J •s 9 L - C-4 Q 0 a) k'r 51Z , �qfj %65 a V) :> 0 .0 E my6 o 65b 8� c +1 0 c c t w 02ioz 0 0. ZiFS us X-3 V) o 06 Mre) !j z 0 Wff) I LO z D ZW 0 Ld 0 V) 0 00 C-4 6 0 z 0 Z I ) Vz D X0 a Z., a: ' N O S 00'11'46" E - 330.59' (COMP PER PLAT 85-26) rn Tr --roc ., W 0 m 0 :� :JoZ QF -0 :m Ln F - (D LO co it 000 z CL D a) 12 04 0 U M C14 Lo zm 4-1 4" te J •s 9 L - C-4 Q 0 a) k'r 51Z , �qfj %65 a V) :> 0 .0 E my6 o 65b 8� c +1 0 c c t w 02ioz 0 0. ZiFS us X-3 V) o 06 Mre) !j z 0 Wff) I LO z D ZW 0 Ld 0 V) 0 00 C-4 6 0 Municipality of Anchorage Development Services Department Building Safety Division , OnS to Water & Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 018-292-09 HAA# 19-9 1. GENERAL INFORMATION Expiration Date: % — 12, Complete legal description T12N. R3W. SECTION 33: LOT 138 Location (site address or directions) 3260 PORCUPINE TRAIL • ANCHORAGE. AK. 99516 Current Property owner(s) KEN ZIEGAHN Day phone (907) 345-5770 Mailing address Lending agency Mailing address Real Estate Agent Mailing address 3321 PORCUPINE TRAIL • ANCHORAGE. AK. 99516 Day phone JOYCE BEEBE w/ PRUDENTIAL. JACK WHiTE Day phone 563-5500 3801 CENTERPOINT DRIVE, SUiTE 200 • ANCHORAGE, AK. 99503 Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well N Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also Issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of Issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixedhereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined In the Health Authority Approval Guidelines forthis application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the Information obtained from the Municipality of Anchorage files and from my investigation and Inspection, the on-site water supply and/or wastewater disposal system Is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations In effect at the time of installation. Name of Finn GARNESS ENGINEERING GROUP, Ltd. Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 Engineers Printed Name JEFFREY A GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, Ltd. attempted to provide a thorough, conscientious engineering analysts of the system in accordance with ADEC and MOA DSD Guidelines d Regulations. The reported results described the performance of the system under the conditions encountered at the time of the lest, and separation distances measured to readily fdentiriable features. The operational fife of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, Ltd. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report Is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party Is not authorized, nor will It confer any legal right whatsoever. 5. DSD SIGNATURE Phone 337-6179 Date +11 O> ✓ Approved for 3 bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: A�kkkk wk Attachments: HAA Checklist Septic System Advisory Well Flow Advisory (R.v. 1201) Maintenance Agreements Supplemental Engineer's Report Other J.• . 7 WATER AND : R' :—�EVdAfER '. --PROGRAM Original Certificate Date: a- 0s Municipality of Anchorage ' Development Services Department Building Safety Division On -Site Water 6 Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519.66W www.ci.anchorage.ak.us (907) 3437904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: T12N, R3W. SECTION 33: LOT 138 Parcel ID: 018-292-09 A. WELL DATA ►VERIFIED BY BROW WILLIE w/ ARROW PUMP AND WELL well" SATE If A, B, or C provide PWSID# N/A Date completed 1973 Sanitary seal (YIN) YES Total depth •36 fL Cased to •36 ft. FROM WELL LOO Date of test Static water level ft. Well production g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 ml. Nitrate ��npJL. Well Log (YM) NO Wires prop" protected (YM) YES Casing height (above ground) 12+ In. AT INSPECTION 3/14/2005 9 ft. 9.47 9— p.m- Other bacteria —colonies/100 mi. Arsenic: N/A mgA. Date of sample: 3/14/2005 Conected by: GEG. LtD. B. 8EPTIC/HOLDINO TANK DATA Tank Type/Material STEEL Date Installed 9/9-15/1999 Tank size 1250 gal. Number of Compartments 2 Cieanouts (YIN) YES Foundation cleanout (YIN) YES Depression over tank (YIN) NO High water alarm (YIN) YES Date of pumping 3/16/2005 Pumper McDONAUY* PUMPING C. ABSORPTION FIELD DATA Date installed 0/0-15/19" Soil rating .p.d ftjbdrm) 0_7 System type BED Length 45 1L Width 15 ft. gravel below pipe 0.55 ft. Total depth a.a—s 2 Elf. absorption area 675 fe Monitoring tube YES Depression over field NO Date of adequacy test 3/14/2005 Results (PasafFan) PASS For-2—bedrooms Fluid depth in absorption field before test 0 in. Water added 2056gal. New depth 0 In. Elapsed Time: 0 min. Final fluid depth 0 in. Absorption rate »yQ_ g.p.d. Any rejuvenation treatment (past 112 mo.) (Y/N 3 type) NONE KNOWN If yes, give date — D. LIFT STATION *REPAIRED BY A+ HOME SERVICES ON 3'17-06 Date installed9/9-15/1999 Size in gallons 1250 Manhole/Access (Y/N) YES "Pump on" level at42 in. "Pump oft' level at 42 in. High water alarm level at 44 in. Datum BOTTOM OF TANK Cycles tested • Meets alarm & circuit requirements? YES E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAiR station on lot 100'+ Absorption field on lot 100'+ Public sewer main N/A On adjacent lots 100'+ On adjacent lots 1001+ Public sewer manhole/deenout N/A Sewer /septic service line 25'+ Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 1001+ Wells on adjacent lots 1008+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 109+ Building foundation 10'+ Water main N/A Water service the 10'+ Surface water 1001+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION 1 aer* that I have determined through Geld inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date 0/1/00 HAA Fee E 0` Date of Payment Receipt Number 1 (Rev. 11101) Waiver Fee S Date of Payment Receipt Number AAROW PUMP & WEII SERVICE, LLC P.O. Box 110496 Anchorage, AK 99511 Office: (907) 346-9355 • Fax (907) 333-8976 Palmer: (907) 745-9077 • Eagle River. (907) 622.9335 CUSTOMER Y�OTLu�/uf r i MOCCE /OSB SITE T �11r L.. A1IC% M7 &'� �- 3Y5-57 10 J L J iCE O� WELLDEPTH ♦ To c I SWL �— CHLORINATED PUMP DEPTH -- S11LE5 ria h QUANTITY --- -_- - DESCRIPTION - .- PRICE AMOUNT 5�,f ef.4 7e&iu P GJr Q \ �f— /5?,7 ue4P ti y N el �1 w74L Z LABOR HOURS RATE AMOUNT TOTAL MATERIAL TOTAL LABOR WORK ORDERED BY DATE COMP. TOTAL LABOR PAY THIS AMOUNT Z000 Thank You SIGNATURE (I Hereby Acknowledge the Satisfactory Completion of the Above Described Work) TERMS: ACCOUNTS PAYABLE AT 10TH OF MONTH FOLLOWING PURCHASE. SERVICE CHARGE AT RATE OF 1.5% PER MONTH WILL BE CHARGED ON OVERDUE ACCOUNTS. 1 118 1 119 I 120 0 / �O�4OE• : EMPTY NEL TANK S 151 I 152 oS�OF A/pp• I 153A I NOTE: THIS DRAWING IS NOT TO BE MODIFIED FOR USE AS A PLOT PLAN. ORDERED NY: EXCLUSION NOTES: It Is the owners nsponslbglty to determine the existence of any easements, covenants, or restrictions LEGEND: SET FND 5/5'RB w/CAP OO 5/e' RB O do not appear an the recorded subdivision plot. NOTE: 3.25' ALMON. �MONUMENT � K E IV Z I E G A H Nwhich I Under no circumstances should any data hereon be used for NUB s: TACK 0 I I I construction or for establishing property lines. I SURVEY CERTIFICATION: LANTECH has conducted a OVERHANO- W physical survey of this property as shown on this WOOD DECKS- 0 LOT 138 o L g s05 ments exbt other than noted.GRAVEL- ..� 1395 �m 137 A S —BUILT O F: LEGAL DESCRIPTION:SEPTIC �o N CONSTRUCTION SURVEYORS -PLANNERS -ENGINEERS n m / �� / fl N f (fox) 561-6626 aT .. / ANCHORAGE,ENSON ALASKALw (907) 582-5291 h _ EXISTING WORK ORDER MUMSER]DATE, 0 / �O�4OE• : EMPTY NEL TANK S 151 I 152 oS�OF A/pp• I 153A I NOTE: THIS DRAWING IS NOT TO BE MODIFIED FOR USE AS A PLOT PLAN. ORDERED NY: EXCLUSION NOTES: It Is the owners nsponslbglty to determine the existence of any easements, covenants, or restrictions LEGEND: SET FND 5/5'RB w/CAP OO 5/e' RB O do not appear an the recorded subdivision plot. NOTE: 3.25' ALMON. �MONUMENT � K E IV Z I E G A H Nwhich Under no circumstances should any data hereon be used for NUB s: TACK 0 construction or for establishing property lines. FENCE- —x—X— SURVEY CERTIFICATION: LANTECH has conducted a OVERHANO- physical survey of this property as shown on this WOOD DECKS- 0 drawing and that the Improvements situated thereCRETE- on are within the property lines and no encroach- ASPHALT- .." L . ments exbt other than noted.GRAVEL- t A S —BUILT O F: LEGAL DESCRIPTION:SEPTIC STANDPiPES- WATER *ELL - N CONSTRUCTION SURVEYORS -PLANNERS -ENGINEERS 440 WEST 103 99503 (fox) 561-6626 LOT 138, SECTION 33, ANCHORAGE,ENSON ALASKALw (907) 582-5291 WORK ORDER MUMSER]DATE, 30. 2005 1"1MARCH '-50' ""'"85-2 5 T 12 N, R 3 W, SEWARD MERIDIAN 2005 -L -65A NRB v �M W s„ 3M 134 REF 9L376 MUNICIPALITY OF ANC14ORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date l I / I / 196- 1. GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) ci f- M L,o'i 13r9 y S'e c 3.3 y r 12 N, R 3 LV/ 5, H. Location (address or directions) 3 26; 0 pore" p'r n c. Tr et i � (b) Applicant Name Alan C�001 »P' Telephone: Home 3Y "3096 Business Applicant Address (c) Applicant is (check one): Lending Institution ❑ ; Owner/builder ❑ ; Buyer ❑ ; Other ❑ (explain); (d) Lending Institution Telephone Address (e) Real Estate Company and Agent Address Telephone 11 I n (f) Mail the HAA to thefollowingaddress 2. TYPE OF RESIDENCE Single-FamilyO Multi -Family❑ Other Number of Bedrooms 3. WATER SUPPLY Individual Well 1% Community ❑ Public ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite ® Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 n-025(11,84) 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection.''N Name of Firm Ffcc//y Technical Set 4/1(-V Telephone 31/6'/36 -5 - Address ly.u0 _C f1G Sf /�rtC /rl� fdz%� f Ak- 9057(5' Date 1 I / / /f1.3 See uict t 1/e r rved p lejl4er o6l-ed IU/3l/85- 6. gHEP A ROVAL Approved for bedrooms byL�agGc Date �- Approved _Disapproved �� Conditional ,b-Aem'nq 4 s� ...................... �g .1.:°..G ......f.'?�: •. THEODORE F. MOORE 12 N,% CE -3589 Prolessiot;A Terms of Conditional Approval dhep CAUTION Engineer's Seal -,P?--n6, The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 111/841 CIVIL. & ENVIRONMENTAL ENGINEERING • ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 October 31, 1985 ANCHORAGE, ALASKA 99516 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & MOA Dept. of Health and Human Services ENVIRONMENTAL PROTECTION Pouch 6-650 Anchorage, AK 99502 NOV `:19b0 RECEIVED Dear Sirs: By means of this letter I wish to request a waiver of the well to soil absorption area separation requirement from 100 to 90 feet on BLM Lot 138, Section 33, T12N, R3W, S.M. This lot is located near the mouth of Rabbit Creek and has an area of 2.5 acres. The owner of the lot, Mr. Alan Galbreath, wishes to obtain Health Authority Approval of his system in order to obtain refinancing, however a waiver will be required first. I am enclosing copies of relevant documents from your files, and my completed Health Authority Approval forms. According to the as -built inspection report dated 9/17/73, the system consists of a multi -legged narrow drainfield 251 feet long and 103 feet from Rabbit Creek at it's closest point. No monitoring tubes exist in the drainfield, so it's exact position is impossible to determine, however the local topography provides a good indication that it parallels the toe of a fairly steep slope at the extreme outer edge of the creek floodplain. The well was drilled subsequent to preparation of this as - built, but presumably also during 1973. No well log is in your files, nor is one available from the owner or the State Geological Survey. I measured the total depth of the well to be 36 feet below ground level. While this is less than the 40 feet required by Chapter 15.55 which was adopted in June 1975, it is greater than the 30 foot cutoff for groundwater systems specified in 18 AAC 80. By virtue of the fact that the well was drilled prior to current Municipal regulations, and is in conformance with current State regulations, I believe it should be accorded "grandfather" rights as an approvable well. The well casing extends one foot above ground level and is contained in a wellhouse together with a surface suction pump and pressure tank. The well is located approximately 15 feet from the bank of Rabbit Creek and 101 feet from the cleanout of the 1000 gallon concrete septic tank. Based on surface measurements I believe no portion of the drainfield is closer than 90 feet from the well, but it definitely is under 100 feet. I tested the well and septic system on October 22. The static water level in the well drew down only one foot, from 8 feet to 9 feet when pumped steadily at 4.3 gpm. The water sample showed no coliform or other bacterial contamination. The drainfield accepted 450 gallons over a 3 hour period, and was able to absorb over 100 gallons per hour, which is adequate. It appears that a good faith effort was made to maximize separation distances within the constraints of the site, and it is recognized that minor tacit waivers to separation criteria were a common practice back in 1973. The relatively large lot size is another mitigating factor. I believe it would be prudent to grant a waiver at this time. Please call me if you have any questions. Sincerely, a��r� "'��•" �ttiS�,.�®® Ted Moore, P.E. .......................... . THEODORE F. MOORE ; w�'ry CF- 3539 .' ^ A747 Municipality ®2 November 13, 1985 P.O. BOX 6650 ANCHORAGE, ALASKA 99502-0650 (907) 264-4111 TONY KNOWLES, MAYOR DEPARTMENT OF HEALTH a HUMAN SERVICES Theodore F. Moore, P.E. Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 Subject: Waiver Request WR85-050 T12N R3W Section 33 Lot 138 Dear Mr. Moore: This Department has reviewed your request for a waiver of the required 100 foot minimum separation distance between the well and absorption field on the subject property. Your request for a waiver to 90 feet has been denied. The information provided about conditions on the subject lot did not show that the minimum separation requirement was not clearly necessary in this case. Sincerely, '4� o. " Stephen S. Morris Civil Engineer On-site Services SSM/ljw MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) MUNICIPALITY OF ANCHORAGE CHECKLIST - FEBRUARY 1984 DEPT. OF HEALTH & 264-4720 ENVIRONMENTAL PROTECTION Legal Description, (j% N7 p rrv�t �ybC Sec'. 33 'i' IZ N% .i ces S, rt, A. WELL DATA RECEIVE® Well Classification P' -"(" e If A, B, C, D.E.C. Approved (Y/N) NIA. Well Log Present (Y/N) Al Date Completed 1P' 19 s3 Yield 3 110 Total Depth 7F; I Cased to ^ 3G I Depth of Grouting N A Static Water Level Pump Set At Above tyPvgnae Casing Height Above Ground — t D Sanitary Seal on Casing (Y/N) Y' Electrical Wiring in Conduit (Y/N) Separation Distances from Well: Depression Around Wellhead (Y/N) To Septic/Holding Tank on Lot Of '10 C' ; On Adjoining Lots 7 too To Nearest Edge of Absorption Field on Lot YG I ; On Adjoining Lots «� To Nearest Public Sewer Line N,/}. To Nearest Public Sewer Cleanout/Manhole NeA, To Nearest Sewer Service Line on Lot ftl, fF. Water Sample Collected by 7 /-'r t Date 10 /(,9 &5 Water Sample Test Results .5 e' f r %e c /6 - ny Cr% /c: N er bee �e,,Tic Comments B. SEPTIC/HOLDING TANK DATA Date Installed ?1/17 /7 7 Size 1006"oat No. of Compartments ! Standpipes (Y/N) i Air -tight Caps (Y/N) Foundation Cleanout (Y/N) Depression over Tank (Y/N) N Date Last Pumped t 0 0 .? y / 195- Pumping/Maintenance Contract on File (Y/N) W,/1'. ; for N, A, Holding Tank High -Water Alarm (Y/N) N,/I Temporary Holding Tank Permit (Y/N) Separation Distances from Septic/Holding Tank: To Water -Supply Well To Building Foundation II To Property Line > (;6' To Disposal Field To Water Main/Service Line N•A • To Stream, Pond, Lake, or Major Drainage Course 1 19 ( R, d, h es (' Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata 22,5 Type of System Design 3' V -11A cPrei)q fl (� Date Installed f l et 173 Length of Field Width of Field Depth of Field W, Gravel Bed Thickness M Square Feet of Absorption Area '76-3 Standpipes Present (Y/N) N Depression over Field (Y/N) N Date of Last Adequacy Test Nvnz e''evcvvr Results of Last Adequacy Test (U/ 2 -?/$>5 %5% a rRi 5'rc�ir nr�i r Separation Distance from Absorption Field: To Water -Supply Well 96) + To Property Line =0 7 To Building Foundation Lot N• 41 ; On Adjoining Lots To Existing or Abandoned System on To Water Main/Service Line IN, A• To Cutbank (if present) N, r#. To Stream/Pond/Lake/or Major Drainage Course 103 1 O e - A f R J(t jf To Driveway, Parking Area, or Vehicle Storage Area ; iO Comments h(v s)�zn ( er et icwl sc, eeezd /ucrriia� a�. f'etd eo,de-( Yta L be Aw D. LIFT STATION N,(}, Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) C . u�Z UR e2M, Dimensions Manhole/Access(Y/N) "Pump Off' Level at ** Check Permitted Bedroom Rating Against HAA Request ** Vent(Y/N) Pumping Cycles during Adequacy Test. Meets MOA I certify that I have checked, verified, orconformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed C✓ �'�"� 7 !z"� Date I!/(/!.5' Company MOA No. `0 Receipt No. Z�ci 8co Date of Payment ( \- Lk_ Amount: $ Page 2 of 2 72-026 (11,84) . ........................ f � .c .......�� THEODORE F. MOORE G®0 )� .CE-358~��Protcsslona\ 4,`®tee Engineer's Seal GRE( 'R ANCHORAGE AREA BQP IGH Department of Environment Quality 3500 Tudor Road Anchorage, Alaska 99507 INSPECTION REPORT ON-SITE SEWAGE: DISPOSAL SYSTEM NAMEIVA1A ? MAILING ADDRESS�O � MUtil) n ��J -� PHONE LOCATION fAjJ) Of / OrC O /moi/VF T,C'n1,1LEGAL DESCRIPTION ✓ o UT -/ oZ ­ / 3 r 40, 14 T/24Z IC 3 �✓ SEPTIC TANK: DISTANCE FROM WELL — INSIDE LENGTH TILE DRAIN FIELD: ,EJfiNaiq NUMBER OF MANUFACTURER ya��� MATERIAL C,01&1 COMPARTMENTS INSIDE WIDTH_ LIQUID DEPTH. _LIQUID CAPACITY vO°GALLONS. TOTAL LENGTH DISTANCE FROM WELLFOUNDATION--NEAREST LOT LINE,) `� _OF LINES NUMBER OF LINES— DISTANCE BETWEEN LINES /0 /.LTRENCH WIDTH IN. TOTAL EFFECTIVE ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE -0' 3.V DEPTH OF FILTER DEPTH: TOP OF TILE TO FINISH GRADE y MATERIAL BENEATH TILE 0 IN. ABOVE TILE IN. WELL: _ TYPE-f—A6 CONSTRUCTION /� �.��bEPTH —DIS ANCE FROM: i \2 BUILDING NEAREST �_AREST SEPTIC SE -PAG FOUNDAT ION LOT LINE. SEWER LINE--, TANK SYSTEM--- CESSPOOL YSTEM- CESSPOOL -- THEIR - -- APPROVED—DISAPPROVED REMARKS— - -- DISTANCES: �'W� DIAGRAM OF SYSTEM INSTALLED 6V:-�z�-�✓ {{'A/!/%' - -� d`I,�I: - 'i a� - I SEWER LINE DEPTH: _ � M PIPE MATERIAL: LOT SLOPE: kE4 �.C�iNGicea y,� _---�-.__-. ��_.�---1_.-1__. _�>•-moi-_ EL._ ' — -- �PAvyQ'/7 REMAtRRKS/o3a !.% /li 6FLU 'ro ot3 �7 c/ I:TL-''K�'rood ?T191' DATE q-/%-IAPPROVE() G.A.A.B, Form PW -027 GREATER ANCHORAGrAREA BOROUGH 8 � DEPAI2SM ENT OF ENVIRONMENTAL QUALITY PERMIT NO p\`\\\I" s 3330 "C" STREET ANCHORAGC, ALASKA 99503 TELEPHONE 274-4561 SEWAGE. DISPOSAL SYSTEM ® APPLICATION AND PERMIT NAME OF APPLICANT y [ J �S-� _s MAILING ADDRESSD� L=L/" p� PHONE INSTALLATION LOCATION - LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK /3 '� S-a(f- TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH - SOIL. TEST RESULTS —___- z'(-/�f�,�TT I --_ �4 COMPLETION DATE ANTICIPATED-47-A-vvl TO BE INSTALLED BY _.._ s CW' 9 NOTE: THIS DRAIN FIELD OTHER I b..' IT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL. QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE/DOO'TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK -_ FOUNDATION TO SEEPAGE PIT DRAIN FIELD G, SEPTIC TANK TO SEEPAGE PIT WALL _ / ✓_- .i `t.)tw-C I roll ax AREA SIZE-. .. lrF DIAGRAM SEPTIC TANK _ _.-. - SEEPAGE PIT _ D . GRAIN FIELD T'O NEAREST LOT LINE. WELL TO SEPTIC TANK (--. SEEPAGE PIT/00 / DRAIN FIELD _. _ ___ _---_ _. ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC �"�TANK -. SEEPAGE PIT DRAIN FIELD L-� --- SEP'T'IC IANK. _I_ - SEEPAGE PIT LOO ! DRAIN FIELD —. TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL, 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL 13AC111FILL CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. G.A.A.B OR LICENSED DESIGNER �TYP. - fr�,�hyy7>,o�,� OF 'SYSTEM /rlLten 4-i ri I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA E30ROUGH ORDINANCE NO. 26-68 AND THAT THE ABOVE DESCRI/BEEDJ SYS"TEM IS IN ACCORDANCE WITH SAID CODE. DATE�L(L_l C�l �/ / ` �` APPLICANT'S SIGN TURF ■ ■ 11111_■■■ a � �� �a�a ;■ 6 ,� ■ ■ , 1.a 1 I a �u �� ■ ■ a� ■.a� �� � ;\ a a ����fll aaa aaa�■■aaa■� rl�■I��al�� � � j■ ■11 � � I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA E30ROUGH ORDINANCE NO. 26-68 AND THAT THE ABOVE DESCRI/BEEDJ SYS"TEM IS IN ACCORDANCE WITH SAID CODE. DATE�L(L_l C�l �/ / ` �` APPLICANT'S SIGN TURF 8 $o NAME OF APPLICANT INSTALLATION LOCATI LEGAL DESCRIPTION . GREATER ANCHORAGC AREA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330"C"STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4501 SEWAGE DISPOSAL SYSTEM - APPLICATION ARID PERMIT C INSTALLATION OF: SEPTIC TANK l"YEE AND SIZE OF FACILITY TO BE SERVED PERMIT NO. ADDRESS-26-S,�J('(,LKrll a"" S _ PI10NE,.?�%.�3 . DRAIN MELD _ _. OTHER FINANCED THROUGH _ — - —_--_ TO BE INSTALLED BY ._ solL resr RFsul_is—---.---^ � NOTE, TI -115 PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL_ INSPECYION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITI-IOU'L FINAL_ INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC 'I'"ANI( SIZE \—._____ TYPE_ --_._ SEEPAGE AREA SIZE —_.— ___ TYPE -- MINIMUM DISTANCES. REQUIREME=NT'S FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE Pi f � )) _.. DRAIN FIELD SEPTIC TANK TO SEEPAGE Ell WALL <PT �(-i SEPTIC l"ANK __"L.—_ . SEEPAGE PIT DRAIN FIELD J TO NEAREST LOT LINE. ^'\ O I 'I" WELL TO SEPTIC "TANK ______, SEEPAGE PI DRAIN FIELD _ �C) ...... ALSO CONSIDER AREA WELLS. I^ I � /U WATER MAIN TO SEPT C TANK __ . SEEPAGE PIT DRAIN FIELD _ 0I i � ,11 I U SEPT IC -TANK. - 1U(3 . SEEPAGE PIT ' V//11 __. DRAIN FIELD TO RIVER. LAKE. SI REAM. CAST IRON INTO AND OUT. OF SEPTIC TANK AND INTO CRID CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WII11_AAAS W_LS REMOVABLE CAPS. GRAVEL. DACKFILL_� CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. G.A .A .FI OR LICENSED DESIGNER DIAGRAM OF SYSTEM I CF_RIIFY 'THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 2866 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. -- 7� `i DATE X �� APPLICANT'S SIGNATURE (OAA \ � 1141 PA ITITA G`..CG f) 229LAST 51stAVE. -P.O,gC)XGO8I-ANCHORAGE, AI_ASKA99603 TIEIMPHONE 907--279...0483 IFI. FX O^D- 35411) Civil Engineer; Geologists Lana Survoyouc JAMESYJ. ROONEY, P. E. RALPH R. MIGLIACCIO MAI COIN} A. MEN/lES, PJ_ L.S. Cngincerin9 Goolo9isi JAMES H. WE LLMAK P.G. Angust. 22, 1973 Mr. Dave Hamner 705 Muldoon Road Space #5 Anchorage, Alaska R & M No. 36652 G;s a u0 111t- U r�!ER ANCIIe{l�e� ,,A BOROUGH Re: Test Hole and Sail_ Log Report for Sanitary System, Loi_ 138, Suction 33 T73NR3W S.M. Dear Mr. Hamner: We are :submitting herewith the test hosing results and our cormlenes regarding soil conditions encountered at the subject site. This investigation was performed in accordance with your request of August 20, 1973, and those procedures outlined im a letter dated September 13, 1971 by Mr. Rolf Strickland of: the Greater Anchorage Area Borough Department of EnvirOnmental Quality. A single test hole was pelt down within the Lot 138 area for the purpose of defining genera subsurface soil c:ond:i:tions for the pro- posed san.-itary system. Excavation was accomplished with a 1-ractor-- mounted backhoe and Lhe Lest hole was extended to,a. toted depth of 9 feet below ground surface. The final lo„ prepared for OR teat hole his been included :in Drawing A-01. Ground mal -r was encountered in the, test hole at 'a, depth of 9.0 feet. We appreciate nein; g&On LUS oppu,:tuniLy to h]_ o.: _ Vi v_r_ce Le, yuu. Should you have any q-snLons vCh regard to the above, please do m;- hesUat.e to contact no, Very truly yours, It 5 it 13194NERRLNG GEOLOC1:CAL CONSULTANTS Jc-:L , L;`. Rooney JUN: Ph nc: GAAti t/ ANCIUNAU (Alli3 :=•JiS JIJNGAU T H - L 8/20/73 jo C)R(l',J'lJLC SILT SILTY SANDY GRAVEL (C; 11) TO 0, 5 9j) 9. 0 '11 . 1), ME E: T n A 1win em rm ke, t w ra, !,:Clf 1 LLC)Lfrr E,:c[ 1),A, '1,11 W Pit e� .0: Q, 0 f -, at. Al ,.1A N i< D 'l J I N A 11 MUNICIPALITY OF ANCI40RAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL_ PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Dale 1. GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) _ J3 I- N I -o f 13(� Se cmoi t i N R i it', Location (address or directions) 3._260 florc" rne. _ 7--etil (b) Applicant Narne 6 (an (I r'L�ix' � Telephone: Home 3'/5 - 3UYi5 Business _ Applicant Address (c) Applicant is (check one): Lending Institution ❑ ; Owner/builder ❑ ; Buyer ❑ Other ❑ (explain); _ (d) Lending Institution Address ___ - —_ (e) Real Estate Company and Agent Address Telephone _ __ (I) Mail the HAA to the following address: RxCJl) L. 2. TYPE OF RESIDENCE Single -Family X Multi -Family ❑ Other Number of Bedrooms 3 3. WATER SUPPLY Individual Well 1% Community ❑ Public ❑ I elephone C-_ Note: If community well systern, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL Onsite ® Public ❑ Community ❑ Holding Tank ❑ Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page i of 2 76035(11.811) 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below. I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the dale of this inspection. Name of Firm Fla/of "Techn1uc/ Sere /(zr Telephone 3 '16--136-5- Address /5-135$Address _ JI .6 0 -c ho Sf _ 11C40,- e Ate 90 7K Date ( I "Ycq See wutuer rr urJt le -lir r�Pule�( IU/3i/8S 6. )HEP APPROVAL � �%,Aan o �/ � t�� � ..:. � 1, � ro O............... THEODORE F. A10 �cE N, . C[ -3589Tz ••;^ �Q ����rB(E;SSIOCiu �✓� Approved for bedrooms by �'/ °I11• Date �— Approved _!Disapproove�_� Conditional Terms of Conditional Approval QQt_1F4'!je1p CAUTION Engineer's Seal _,_"?—R6 The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the Stale of Alaska. The DHEP does this as a courtesyto purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 FLATTOP TECHNICAL SERVICES CIVIL & ENVIRONMENTAL ENGINEERING • ENERGY CONSERVA770N & ANALYSLS THEODORE E. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 October 31, 1985 ANCHORAGE, ALASKA 99516 MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & MOA Dept. of Health and Human Services ENVIRONMENTAL PROTECTION Pouch 6-650 NOV yn Anchorage, AK 99502 EC'EIVED Dear Sirs: By in ea ns of this letter I wish to request a waiver of the well to soil absorption area separation requirement from 100 to 90 feet on BLM Lot 138, Section 33, T12N, R3W, S.M. `Chis lot is located near the mouth of Rabbit Creek and has an area of 2.5 acres. The owner of the lot, Mr. Alan Galbreath, wishes to obtain Health Authority Approval of his system in order to obtain refinancing, however a waiver will be required first. I am enclosing copies of relevant documents from your files, and my completed Health Authority Approval forms. According to the as -built inspection report dated 9/17/73, the system consists of a multi -legged narrow drainfield 251 feet long and 103 feet from Rabbit Creek at it's closest point. No monitoring tubes exist in the drainfield, so it's exact position is impossible to determine, however the local topography provides a good indication that it parallels the toe of a fairly steep slope at the extreme outer edge of the creek floodplain. The well was drilled subsequent to preparation of this as - built, but presumably also during 1973. No well log is in your files, nor is one available from the owner or the State Geological Survey. I measured the total depth of the well to be 36 feet below ground level. While this i,s less than the 40 feet required by Chapter 15.55 which was adopted in June 1975, it is greater than the 30 foot cutoff for groundwater systems specified in 18 AAC 80. By virtue of the fact that the well was drilled prior to current Municipal regulations, and is in conformance with current State regulations, I believe it should be accorded "grandfather" rights as an approvable well. The well casing extends one foot above ground level and is contained in a wellhouse together with a surface suction pump and pressure tank. The well is located approximately 15 feet from the bank of Rabbit Creek and 101 feet from the cleanout of the 1000 gallon concrete septic tank. Based on surface measurements I believe no portion of the drainfield is closer than 90 feet from the well, but it definitely is under 1.00 feet. I tested the well and septic system on October. 22. The static water level in the well drew down only one foot, from 8 feet to 9 feet when pumped steadily at 4.3 gpm. The water sample showed no coliform or other bacterial contamination. The drainfield accepted 450 gallons over a 3 hour period, and was able to absorb over 100 gallons per hour, which is adequate. It appears that a good faith effort was made to maximize separation distances within the constraints of the site, and it is recognized that minor tacit waivers to separation criteria were a common practice back in 1973. The relatively large lot size is another mitigating factor. I believe it would be prudent to grant a waiver at this time. Please call me if you have any questions. ®1AWUA c>a V 4 ����.•'` °ear o ✓3 t'd 7i 9-H flue r... oo....e a eeeeeeiet..� A.e. ia0.6ee BseQ THEODORE F. MOORE ; ,�d�J�.eo•°°eee.eee°°.°O 6 c?t! Sincerely, Ted Moore, P.E. JAvu-iniicipahty OF Andaurage November 13, 1985 P.O. BOX 6650 ANCHORAGE, ALASKA 99502-0650 (907) 264-4111 TONY KNOWLES. MAYOR DEPARTMENT OF HEALTH & HUMAN SERVICES Theodore F. Moore, P.E. Flattop Technical Services 14530 Echo Street Anchorage, Alaska 99516 Subject: Waiver Request WR85-050 T12N R3W Section 33 Lot 138 Dear Mr. Moore: This Department has reviewed your request for a waiver of the required 100 foot minimum separation distance between the well and absorption field on the subject property. Your request for a waiver to 90 feet has been denied. The information provided about conditions on the subject lot did not show that the minimum separation requirement was not clearly necessary in this case. Sincerely, Stephen S. Morris Civil Engineer On—site Services SSM/ljw MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) MUNICIPALITY OF ANCHORAGE CHECKLIST - FEBRUARY 1984 DEPT. OF HEALTH & 264-4720 ENVIRONMENTAL PROTECTION Legal Description: 18/-M l 00 Sec. 33 'i LZ N R .3 1" A. WELL DATA RECEIVED privu� Well Classification If A, B, C, D.E.C. Approved (Y/N) N,A. Well Log Present (Y/N) Date Completed 19 73 Yield m Total Depth —;ice Cased to 1 3G Depth of Grouting Static Water Level i3 b"6CV crrk an i feoef Pump Sot At Above givccAaC Casing Height Above Ground I Z Sanitary Seal on Casing (Y/N) —y Electrical Wiring in Conduit (Y/N) Depression Around Wellhead (Y/N) n� Separation Distances from Well To Septic/Holding Tank on Lot 4& Ct o', -- ; On Adjoining Lots _ 7 Cvo ' To Nearest Edge of Absorption Field on Lot =Y6 On Adjoining Lots lc9e — To Nearest Public Sewer Line —A_ATo Nearest Public Sewer Cleanout/Manhole NIA• To Nearest Sewer Service Line on Lot N A Water Sample Collected by 77�fY ; Date _ f V M9 / & Water Sample Test Results Sa}trL— ae-kr•V — o o Co<<%a`/" or o lhe� 6cec�era;t Comments B. SEPTIC/HOLDING TANK DATA Date Installed P/17/7—?—Size LGOU Dat No. of Compartments Standpipes (Y/N) Air -tight Caps (Y/N) )° Foundation Cleanout (Y/N) �( Depression over Tank (Y/N) N — Date Last Pumped 10/ Z y / o5 Pumping/Maintenance Contract on File (Y/N) N C)• ; for N, A. Holding Tank High -Water Alarm (Y/N) NTA. Temporary' Holding Tank Permit (Y/N) Separation Distances from Septic/Holding Tank: To Water -Supply Well 10 f OroTo Building Foundation If To Property Line>.3v 1 To Disposaffield ' - 2 To Water Main/Service Line NA • -- __ To Stream, Pond, Lake, or Major Drainage Course It t Comments Page 1 of 2 72 -026(11184) c Creel - C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata 2�s q 18,rfrm Type of System Design 3' Wiek' C, r 117f'eJrt Date Installed 91/ef /73 Length of Field e5,r Width of Field Depth of Field Nr Gravel Bed Thickness M Square Feet of Absorption Area -7,63 Standpipes Present (Y/N) N Depression over Field (Y/N) N Date of Last Adequacy Test None preyrorc/ Results of Last Adequacy Test _f0/ 42- fa&k cur✓✓ SceA"JGCk. Separation Distance from Absorption Field 1 To Water -Supply Well =� 90+ To Property Line Z, "e'0 r To Building Foundation To Existing or Abandoned System on Lot N. r}. On Adjoining Lots > 100 r To Water Main/Service Line N. A - To Cutbank (if present) 1414. To Stream/Pond/Lake/or Major Drainage Course 103' P e At -- R at [ f To Driveway, Parking Area, or Vehicle Storage Area Comments N(o SlaAd,/Jr,__pzt Arp e,,71 So 4-,rrcc% lucrr/rr✓n of _Petd co"&( no by del-erlrio&w, tweet--/ ,6 40tlbw foci er All D. LIFT STATION N,q, Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) — Comments Dimensions Manhole/Access (Y/N) "Pump Off" Level at ** Check Permitted Bedroom Rating Against HAA Request ** Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed T 97Z"'t Date (/ %l /A5 Company hJiz6* '7_0c1 n'cr/ –QU MOA No. OS ?- Receipt No. Date of Payment Amount: $ Page 2 of 2 72-028 (11/84) ...�......®........•...�...f ...0 �........ E e.ee.ee..eu.e °•a4 THEODORE r. MOORE ; A CE - 3589 w; 0 Engineer's Seal