Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T15N R1W SEC 7 LT 65
Municipality of Anchorage Pegs 1 of 2 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchoroge, Aloska 99519-6650 Telephone: 545-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW990233 PID Number: 051 --161 --14 EDWARD BEEMAN WastewaterSystem: [] New [] Upgrade PO BOX 670154 CHUGIAK, AK 99567 ABSORPTION FIELD No. of Bedrooms: Ph°ne:~907/( ~ 244-9218 DDeep Trench m Shollow Trench nBed OMound OOther 65 2,0 ~, 5.0 Town°hip: 15N Range: lW Section: 7 Fill odded obeys odglnol gr~de: Grave/ 1.0 ~, 45 ~, WELL: [] New [] Upgrade 5 ~, 1 - ~ n. 588 s~. F~, ASTM D-5054/F-810 n. WHITTERS CONSTRUCTION 8/12 - 18/99 SEPARATION DISTANCES m Septic [] Holding [] S.T.E,P. To Septic Absorption Uft Holding Subllc/Pr~vot° Monufacturer:. Copaol[7 In gallonB: From Tank Field Station Tank S~w~r U.. ANCHORAGE TANK 1000 Well 100'+ 100'+ - - 25'+ STEEL 2 SurfeCewater 100'+ ~0o'+ - - - LIFT STATION Line Foundotion 5'+ 1 0'+ - -- - Drain NONE KNOWN I I Remarks: BENCH MARK TOP OF LOG SONOTUBE © SOUTHWEST CORNER OF HOUSE. 100,00 Inspections pefformed by:_ AWWC, INC. Dates:lst_ 8/12/99 3rd 8/18/99 ,^.p .~ef~r~'/~, Garness,,' Department of Health and Human Services approval ~/O0~,j...CE~ 705,~......'~,~ Reviewed and approved by: g)///~;' ~,//~/...~°-'~ Date:. /o-~¢ffL ;'ERMIT NUMBER: swgBo233 AS-BUILT DRAWING I~ 100' WELL RADIUS ~n / I ~r~ / ~ ,3 BEDROOM fOCOffR4K ~ = J I : / /- fO~O~fANK \\ HOUSE / k[~A/ [~ ~A[ I~X[ ~ GALLON SEPTIC ~ k ~~ ~ 100' WELL ~DIUS ~ ALASKA WATER AND WASTEWATER CONSULTANTS, INC. ~~,l 6B01 DESARR ROAD BUITE 2B, ~CHO~GE, AK 99504 LEGAL DESCRIPTION: ~P[ OF WOR~: AS-BUILT OF SEPTIC SYSTEM UPGRADE PREPAREO FOR: PHONg NUMBER: DA~E:8/25/99 BY:K.D,W. 1 = 40' 2 OF 2 A B ST1 79,9 63.8 ST2 85,9 69.9 DBL1 90.2 74-,1 DOL2 91.7 75.7 MT1 134,8 119.8 C01 1..'15.7 120.6 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 995~9-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Jul 29, 1999 Expiration Date: Jul 28, 2000 Permit Number: SW990233 Legal Description: T15N R1W SEC 7 LT 65 Design Engineer: 0041 AK Water & Wastewater Consulta Owner Name: Edward Beeman Owner Address: PO Box 670134 Chug[ak, AK 99567- Parcel ID: 051-161-14 Site Address: 019731 TENADA AVE Lot Size: 108900 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters I5.55 and 15,65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at [east 2 hours prior to each inspection, Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: _ , ~ , ~, ~ _ ¢ Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road, Suite 2B ~ Anchorage ~ Alaska 99504 (907) 337-6179 N Fax (907) 338-3246 Consulting Engi~eers July 2, 1999 Municipality of Anchorage Department of Health & Human Se~wices Division of Enviromnental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 Ref: Septic Upgrade Design for BLM Lot 65, SE 1/4, Section 7, T15N, R1W, To whom it may concern: The existing 3 bedroom house is served by a private septic system and a private well. The existing septic system is undocumented and is believed to be a cesspool or crib. A test holel/was excavated to the south/southwest of the existing septic system. Comments regarding the proposed design are summarized as follows: 1. SOILS: Attached is a log which shows the soil profile, and the percolation test result. The soils below the organic layers is a GW material to a depth of 3 feet and then transitions into a GM material to a depth of 15 feet (bottom of test hole). Groundwater was encountered at 13 feet during the excavation of the test hole. A percolation test was performed between the depth of 5.5 feet to 6.0 feet which had a percolation rate of 2.8 minute/inch. 2. TRENCH DESIGN: a. Percolation Rate: 2.8 minutes/inch b. Allowable Application Rate: 1.2 gallons/day/ft2 c. Number of Bedrooms: 3 d. Design Flow: 450 gallons per day e. Minimum Absorption Area: 375 ft2 f. Total Depth: 6 feet (max.) g. Effective Depth: 3 feet h. Width: 5 feet minimum i. Reduction Factor: 0.58 i. Minimum Length: 45 feet long j Effective absorption area = 388 ft2 3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed upgrade. 4. TOPOGRAPHY: The average topography in the area of the proposed drainfield is mostly fiat and then transitions to a 10 to 15 percent slope west of the proposed drainfield; in short, there are no slope concerns. I am unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact me at 337-6179, or 244-9612. Thank you for your assistance./] ,// PresCript ~ NOTE: Attached ia' a site plan drawing, a design drawing, a soils log and a 4 page construction specification letter which are all part of the design package for this septic system. iI I ~/ / MICHLIG S/D .-~ '~ ~ BLM LOT 39, SE 1/4, SEC. 7, T15N, / / ~ , / / ~ - loo W~LL ~US ~ EXIS~NG / SEPTIC , I · HOUSE / SYSTEM ~ ~ ~ J / ~ROPOS~/SEP~ N~ 5~ / // ~ /~/ I BLM LOT 66, SE SEC. 7, T15N, RlW / I BLM LOT 88, SE 1/4, / I SEC. 7, T15N, RlW / BLM LOT 70, SE 1/~, [ / SEC. 7, T15N, RlW BLM LOT 69, SE 1/4, j / SEC. 7, T15N, RlW ~ / I / I / / / / 6901 DEBARR ROAD, SU,TE 28. ANCHO~E, A~. 99504 ~.~/~ ~ SITE PLAN FOR SEPTIC UPGRADE · ~ ..... ;...,~ ED BEE~AN (907) 8 J SCALE: PAGE: ~1~ h ...... ~ DATE:7/~/Bg K.D.W./J.L,M. ~ = ~00' ~ Or 2 II i \ I EXISTING UNDOCUMENT I 100' WELL RADIUS EXISTING CESPOOL OR CRIB TO BE I,,,~ OWELL ABANDONED CO M P LDI'ELY;--,.k II ~ / EXISTING ~, 3 BEDROOM ~x. HOUSE j / PROPOSED 1000 GALLON \% ~, ~ J / SEPTIC TANK --~ \\~ e0 [ ~ /I PROPOSED DRAINFIELD UPGRAD~ X V~ A X /~ / EXCAVATE 6 FE~ DEEP MAXIMUM ~ ~J /I ~. ~ ~ // BY 5 FE~ WIDE BY 45 FE~ LON~ ~ ~/ ] ~% ~ ADD 3 FE~ OF CLAN, WASHED ~ ~ / ~ ~ // I S~ER DRAINROCK~ ~ ~ /x. / % ~ / / /~m: THE COmRACTOR SHALL HAVE BOTH 100 RADII / / ~R~¢~G-~GGED BY A REGISTERED --+- / / //// ~NB SURV~OR PRIOR TO ANY CONSTRUCTION. / ALAS~ WATER AND WASTEWATER CONS~TANTS, ~C, 6901 BEBARR ROAD SUITE 2B, ~CHO~GE, ~ 99504~ .~ ~~/~m~ ELM LOT 65. SE 1/4, SECTION 7, T15N, RlW, ¢ *. ) "~' ~PE OF WORK: DESIGN OF SEPTIC SYSTEM UPGRADE 244-9218 ~$~ '~. .... ED BEEMAN (907) v ~ ". ~-'~ ." D~WN SCALE: PAGE: ~?~2 ......... 0AT~:7/2/99 eY:J.L.M. 1 = 40' 3 OF 3 ALASKA WATER & WASTEWATER CONSULTANTS, INC. ,~ ..~h A I somLLOG - PERCOLATIONTEST I DATE PERFORMED: 8/23/99 (f~oU~¢~ ORGANICS TEST HOLE ~1 SM OH 10[=J I J (/ TENADA AVENUE 11~J~J[[~ DATE READING CLOCK NET TIHE WATER LEVEL NET DROP TIHE (HINUTES) READING (INCHES) 12~JLJJJF 6/29/99 1 3~15 6" 13 ~ 3 3=26 6" 7 3:48 ~ 6. 9 3~59 19 PERCOLATION RATE 2.8 (HIN./INCH) PERC. HOLE DIA. 6" (INCHES) 20 TEST RUN BETWEEN 5.5 FT. AND~FT. COHHENTS: PERO HOLE PRESO~ED FOR ,+ HOURS P;~C ~/~.~/ PERFORMED BY ,~S~ WATER, WAST,ATER ,. ~4/ ~'(t% , OERT'~ THAT THIS WAS PERFORM~D~N ACCORDANCE WITH ALL STATE &~ ~UNIdI~GUlBELINES IN EFFEOT ON THIS DATE. DATE: 'Z/l~/~f / ¢ DEPTH TO GROUNDWATER DATE 13' 6/23/99 11' 8/28/99