Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
VALLI VUE ESTATES #2 BLK 3 LT 11A
Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~'Lc/ ?~20'°77 PIDNumber: 013--'3¥1-5'V Name: FroT,~ ~ ~y ~,~ Wastewater System: ~ New ~Upgrade Address: E~/~z A~ ~ ~,., ~ ~ ABSORPTION FIELD iNc. of Bedrooms: Phone: ~ ~/~--~O~ ~ ~ Deep Trench ~ Shallow Trench BRed ~Mound ~Other LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: Subdiv~ion: Depth to pipe bottom from original grade: Gr~vel depth beneath pipe Township: I Range: Section: Fill added above original grade: Gravel length: I ~ I Ft. ? WELL: D New D Upgrade Gravel width: Number of lines: I Distance betweenlines: Classilication (Private, A,B,C): Total Depth: Cased TO: Total absorption area: Pipe material: r-~l Ddl~er: Cate Drilled: Static Water Level: Installer: Date installed; Yield: GPM Pump Set ah Ft. ~ Casing Height Above Ground:Fi, SEPARATION DISTANCE8 ~ septic ~ Holding ~ S.%E.P. From Tank Field Station Tank Sewer Lines ~ C~ ~¢~ ~ ~ ~ J Sudace LineL°t J ~ ~ ~ - - Size in gallons: ~ Manufacturer: I -- -- _ "Pump Oh"level at: I "Pump off"level at: ~ High water alarm at: Cudain ~ -- · Pump Make & Mode~ ~ Electrical Inspections pedormed by; Drain I Remarks: %h;j ~¢~ ¢~¢~¢j ¢~ BENCHMARK ¢ Location and Description; Assumed Elevation: ENGINEEW8 SEAL Inspoctions porformod by: '~/~J~F T~c4 ~c Batos: ~st Department of Health and Human So.ices approval PERMIT NO: SW990077 PID NO: 015-341-64 SWING TIES: '~!~ '~ NEW 45' LONG SOIL ABS. TRENCH W. 9.0' GVL. BELOW PIPE (~T.H. #1 FROM: COR."A" COR."B" COR."C" COR. "D" TO: S.T.C.O. "F" 33.3' 9.8' 25' S.T.C.O. "G" 36.6' 16.8' 28' C.O. "H" 37.3' 18.5' 29.5' VALVE "1" 37.7' 19' 30' DBL. C.O. "J" 39' 20' 29' TR. C.O. "X" 36.6' 30' TR. M.T. "Y" 40.5' 34.5' TR. C.O. "Z" 80,5' 69' PLAN VIEW SCALE: 1" = 5' "BULL RUN" DIVE VALVE "1" PAGE 2 OF 2 LOT 11A BLOCK 3 4-BDRI HOUSE DECK NEW 1250 GALLON SEPTIC TANK SEEPAGE ORIG. GROUND ELEV. 95.4 ELEV. 99.4 NV¸ 45' LONG SOIL ABS. TRENCH W. 9.0' GRAVEL BELOW PIPE BOTTOM TRENCH ELEV. 83.4' BOT. T.H. #1 ELEV. 77.4 (M.T. DRY 5/12/99) INV. 95.7 1250 GALLON SEPTIC TANK INV. 98.0 PROFILE VIEW NOT TO SCALE LOT 11A, BLK. 3, VALLI VUE EST. #2 SEPTIC SYSTEM UPGRADE AS-BUILT INSPECTION REPORT FLATTOP TECHNICAL SERVICES 14530 ECHO STREET ANCHORAGE, ALASKA 99516 SCALE: AS NOTED DRAWN BY TFM SEPTEMBER, 1999 MUNICIPALITY OF ANCHORAGE Depai~ment of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box ~96650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Apr 30, 1999 Expiration Date: Apr 29, 2000 Permit Number: SW990077 Legal Description: VALLI VUE ESTATES #2 BLK 3 LT 11A Design Engineer: 0019 Flattop Technical Services Owner Name: Floyd & Mary Bettis Owner Address: 6442 Lone Tree Circle Total Bedrooms: 3 Anchorage, AK 99516-6740 Parcel ID: 015-341-64 Site Address: 006442 LONE TREE CIR Lot Size: 20771 SQ. FT. Permit Bedrooms: 3 rmit is for the construction of: posal Field [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( '18AAC72 ) and Drinking Water Regulations ( 18AACS0 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Issued By: Date: Rick Mystrom, Ma?or Municipality of Anchorage Department of Health and Human Services 825 "L" Street P,O. Box 196650 Anchorage, Alaska 99519-6650 http://www.ci.anchorage.ak.us Flattop Technical Services ATTN: Theodore E. Moore, PE 14530 Echo Street Anchorage, AK 99516-0000 June 11, 1999 Subject: Waiver Request for VALLI VUE ESTATES #2 BLK 3 LT 1 lA Waiver # WR990031 Lot Line Request for Parcel ID 015-341-64 Dear Engineer: Your request for a waiver of the required 10 feet horizontal separation of the on-site wastewater disposal system to the lot line has been approved. The approved separation distance is 3 feet. This waiver approval applies to the current on-site wastewater disposal system and lot line separation only. Any future upgrade to the on-site wastewater disposal system and lot line will require all separation distances to be met or another waiver approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, o~nn~a C. Mears Civil Engineer I On-Site Water Quality Program WR~ [1_%,0 ~i]~5\ PID# 015-341-64 HA9 Date Received: May 25, 1999 Legal Description: Lot llA Block 3 Valli Vue Estates #2 Engineer: Ted Moore, PE, Flattop Technical Services MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-site Services Section Waiver Review Worksheet Permit #SW990077 14530 Echo Street, Anchorage, Alaska 99516 Applicant: Floyd & Mary Bettis Waiver Requested: Lot line waiver of 3 feet from the trench to the common property line of Lot 38A. Criteria: 1. Geology: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: 2. Special Conditions: Points: 3. Other: Waiver is Granted: Waiver is NOT Granted: List Conditions or Reasons for above: Date: By: Rec #: 04851/4508 Amount: $ 115.00 Date Paid: May 25~ 1999 CWIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS THEODORE F. MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 May 24, 1999 ANCHORAGE, ALASKA 99516 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: The purpose of this letter is to provide the required design narrative in support of our application to amend permit #SW990077 (which was issued for a septic tank replacement, only) to include construction of a new soil absorption trench, thereby upgrading the system to 4-bedroom capacity. This permit applies to Lot 1 lA, Block 3, Valli Vue Estates #2, located at 6442 Lone Tree Circle. A soils log, perc test results, a site plan, design drawings and specifications are enclosed for your review. The proposed site for the upgrade trench is less than 10 feet from the property line; the site was selected in order to minimize damage to existing large trees. To legitimize this location, a lot line waiver is requested allowing the system to be within 3 feet of the property Iine common with Lot 38A. Because all of the lots in this subdivision are served by a community water system, granting this waiver should not significantly impact the ability to construct future upgrades to the septic system serving Lot 38A. The proposed system will be constructed in the vicinity of test hole # 1. As can be seen from the soil log, the native material between 3 feet and 18 feet below ground level is a fine, somewhat silty sand with a measured perc rate of 5 minutes per inch. Using the soil application rate of 0.8 gpd/sq, ft. specified in the wastewater ordinance for soils with a measure perc rate of 6 - 15 minutes per inch, this 4-bedroom residence requires a total absorption area of(4 x 150)/0.8 = 750 square feet. The proposed 45-foot long trench design with an effective gravel depth of 8.5 feet has a total absorption area of 810 square feet. The topography of the lot in the vicinity of the proposed construction slopes down towards the southwest at approximately 3%. There is a platted drainage easement along the northwest property line, approximately i5 feet from the end of the proposed trench. However, it has remained dry throughout breakup this year and there is no sign ora streambed in it that regularly carries water. I discussed this drainage easement issue with Dan Roth on May 3rd, and he informed me that in this situation there is no need to maintain any prescriptive separation distance from the easement. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on reserved space-surface and 9ubsurface, or on drainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. LOT 12 CONSTRUCT 45'LONG SOIL ABS. TRENCH W. 8.5'GRAVEL LOT 11A BLOCK 3 SITEFOR REPLACEMENT TRENCH WATER KEY BOX ,, APPROX. LOCATION :~ SERVICE LINE LOT 38A CO SEPTIC O SYSTEM O NOTE: ALL HOMES IN THIS SUBDIVISION ARE SERVED BY A CLASS "A" COMMUNITY WATER SYSTEM EXISTING 4-BDRM HOUSE "BULLRUN" DIVERSION VALVE DECK ,, ' ' 'NEW 1250 " GALLON SEPTIC TANI( SEEPAGE LOT 39 o SEPTIC SYSTEM LOT 10 BLOCK 3 o 'OT LI1A, B3, VALLI VUE EST. #2 SEPTIC TANK REPLACEMENT SITE PLAN FLATTOP TECHNICAL SERVICES 1 INCH = 30 FEET 14530 ECHO STREET DRAWN BY TFM ANCHORAGE, ALASKA 99516 REV. 5/13/99 NOTE: THIS IS NOT A SURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. LOT 1'IA BLOCK 3 WATER KEY BOX APPROX, LOCATION LINE LOT 38A 4OUSE INSTALL NEW 1250 GALLON -- SEPTIC TANK INSTALL DOUBLE C.C. TIE DISCHARGE LINEINTO EXISTING SEEPAGE PIT SEEPAGE PIT 3-BDRM ALL HOMES IN THIS SUBDIVISION ARE SERVED BY A CLASS "A" COMMUNITY WATER SYSTEM DECK' LOT 10 BLOCK 3 PROPERLY ABANDON EXISTING 1000 GALLON ~ ,'SEPTIC TANK SEPTIC SYSTEM o LI1A, B3, VALLI VUE EST. #2 SEPTIC TANK REPLACEMENT SITE PLAN FLATTOP TECHNICAL SERVICES 1 INCH = 30 FEET 14530 ECHO STREET DRAWN BY TFM ANCHORAGE, ALASKA 99516 AP R L, 1999 NOTE: THIS IS NOT A SURVEYED PLAT. ALL LOCATIONS SHOWN ARE APPROXIMATE. / "A" I1--~. ~ 4" DIA. F-810 NON-PERF, PIPE / _CONSTRUCT 45' LONG "BULL RUN" SOIL ABSORPTION TRENCH DIV. VALVE W, 8,5' GRAVEL BELOW PIPE. PLAN VIEW SCALE: t" = 10' 3 MONITORTUBE CLEANOUT OUND BACKFILL12" JAL GROUND FILTER FABRIC 4" DIA. F-810 PERF. PIPE 1/2" - 2 1/2" SEWER GRAVEL OFTRENCH SECTION "A - A" SCALE: 1" = 5' LOT i lA, BLK, 3, VALLI VUE ESTATES #2 SEPTIC SYSTEM UPGRADE PLAN AND CROSS-SECTION FLATTOP TECItNICAL SERVICE8 SCALE: AS SHOWN 14530 ECHO STREET DRAWN BY: TFM ANCHORAGE, AK, 99516 MAY, 1999 Flattop Technical Services 14530 Echo Street, Anchorage, AK 99516 Phone (907) 345-1355 Lot llA, Block 3, Valli Vue Estates, Unit #2 6442 Lone Tree Circle Wastewater disposal system installation Amended Specifications - May 1999 1.0 General: 1.1 The scope of the project consists of construction ora 45-foot long soil absorption trench with a total of 9 feet of sewer gravel between 3-feet and 12-feet below ground level. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform to Municipal and State requirements. Ail separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 2.0 Septic Tank: 2.1 A new 1250-gallon septic tank has already been installed, along with a "Bull Run" diversion valve allowing for hookup to the proposed new trench. 3.0 Soil absorption system: 3.1 The soil absorption system shall be constructed by excavating a 45-foot long trench to a total depth of 12 feet below original ground level in the vicinity of tho test hole. 3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be raked to allow proper infiltration. 3.3 A total of 9.0 feet of approved sewer gravel shall be placed in the bottom of the excavation with the perforated distribution pipes laid level such that the pipe inverts are no less than 8.5 feet above the bottom of the sewer graveI. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A minimum of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in addition to the filter fabric. 3.6 The top surface of the cover material shall be raised a minimum of 6 inches higher than the surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1. 3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and seed to promote rapid revegetation of all areas disturbed by the construction. 4.0 Inspections: 4.1 A minimum of 4 engineering inspections will be required during the course of the project: (1) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and grading is complete. 4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. TEST HOLE LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH (feet) 1 2 3 4 5- FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST Lot 1 lA, Block 3, Valli Vue Estates, Unit #2 May 4, 1999 Floyd and Mary Bet[is Pt. GM Silty, gravelly loam SM Fine, somewhat silty sand Dry, non-cohesive, easy digging LOT12 SLOPE SITE PLAN 2[ COMMENTS: Depth to Groundwater Date No groundwater May~4, 1999 Monitor tube dry_ ~V!~, 1999 DOUBLE C.C. NEVVI250qALLON SEPTICTANK 3% B.H.(Rock) Date Reading Clock Net Time Percometer Net Drop Time (minutes) Reading (inches) ~/4/99 12" Presoak 27 3/8 Add water & start 10:26 23 5/16 #1 10:41 15 19 11/16 3 5/8 Add water 10:41:30 23 7/16 #2 10:56;30 15 19 3/4 3 11/16 Add water 10:57 23 7/16 #3 11:12 15 19 3/4 3 11/16 PERCOLATION RATE 5 (minutes/inch) PERC HOLE DIAMETER 6" TEST RUN BETWEEN 7.5 FT AND 8.0 FT Recommend trench be sized on bas s of 0.8 gpd/sq, fi: Drainage easement along NW property line dry 5/12/99 PERFORMED BY FLATTOP TECHNICAL SERVICES. I .~.~..,~ "'~'1,¢.,,.~,~.(~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: .5"-/~-- ¢ /:¢ ~ GRE/ FR ANCHORAGE AREA BO[ Department of Environmental (~ualJty 3330 C Street Anchorage, Alaska 99503 JGH INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM LOCATION SEPTIC TANK: DISTANCE FROM WELL INSIDE LENGTH MANUFACTURERC~F-t~%~-~ NUMBER OF MATERIA~/~ /'7~/7~5~ COMPARTMENTS '"~'~-1~TDE WIDTH ~ --IglQUlD DEPTH " ~.LIQUID CAPACITY /~ (~ GALLONS. SEEPAGE Pit: NUMBER OF PITS / DIAMETER-~=~ LINING MATERIA -~ ~ tl~ ~,~ CRIB SIZE: BUILDING FOUNDATION ~] , ADDITIONAL ABSORPTION NEAREST LOT LINE OR WIDTH~'~(~, LENGTH'~2'3, DEPTH /,.~ DIAMETER ~'/' DEPTH DISTANCE FROM: WELL L/~-~}~'~ / TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) ~ ~/~:/' SQ, FT. WELL: FOUNDATION CONSTRUCTION NEAREST LOT LINE CESSPOOL APPROVED OTHER SOURCES DISAPPROVED DEPTH DISTANCE FROM: NEAREST SEPTIC SEEPAGE SEWER LINE TANK __ SYSTEM REMARKS DISTANCES: INSTALLED "Y: PIPE MATE RIAL:/¢~J~ LOT SLOPE: REMARKS: .<~3c~_ /~;~1 d~.~;"C) ~'~ Form No. LQ-031 DIAGRAM OF SYSTEM DATE~',~,C~ ,¢0/~; /97z'// APPROVED /}¢,4/~.,~ ~,,~'2_)¢~/]//1F~f~l,r"' ',7// G,A.A.B. NAME Of APPLICANT GREATEr ANCHORAGE AREA Borough DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT PERMIT NO. , OTHER INSTALLATION LOCATION LEOA DESCR,PT,ON I/ /1: INSTALLATION OF: SEPTIC TANK ~"~- SEEPAGE PIT ~ ., DRAIN FIELD TYPE AND SIZE OF FACILITY TO SE SERVED 3 ~--~m : ~ /~' i~' /~'~' SOIL TEST RESULTS ~ , ~ NOTE= THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK FOUNDATION TO SEEPAGE PIt ~ , DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL SEPTIC TANK , SEEPAGE pIT DRAIN FIELD DRAIN FIELD _ , ALSO CONSIDER AREA WELLS, DIAGRAM OF SYSTEM WATER MAIN TO SEPTIC TANK , SEEPAGE PIT DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRib CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SO~L. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE Pit FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BOROUGH~EG?~TION$ REGARDING INSTALLATION. :/' .//.:? . [ CERTIFY THAT I AM FAMiliar With THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. GREATER ANCHORAGE AREA BOROUGH BEPARTMENT OF ENVTRONMFNTAL QUAI. ITY 3330 "C" Street ANCHORAGE, ALASKA 99503 Performea For_ ~-F~MF~E~. ~1~-I\~ ~-~_~. ~R~ Dated Performed Legal Description: Lot /! Block. ~ Subdivision This Form Reports Soils Soil Test Must Be Logged To 4' Below Depth Feet Soil Characteristics Case # Percolation Test Proposed Seepage System - Was Ground Water Encountered? A~/~ ~^ If Yes, At What Depth? I Reading Date Gross Time Net Time Depth to H20 Net Drop Percolation Rate Minute Proposed Installation: Seepage Pit Drain Field Depth of Inlet Depth =co Bottom o~--Pit or Trench COMMEUTS: Test Performed BY .... Date Certified BY: Date: !, ~artment of Environmental Quality ' ,~ater and Sewer Questionnaire Owner's Name: ~ ~ Mailing Address: ~, . ~ ,~ ~,~, ~ . Questions: 1. }Iow many bedrooms are now in your house? 2. How many bedrooms were in the house at the time of purchase? 3. Were the basement bedroom walls "roughed in" at the time of purchase? 4. Was the basement bathroom plumbing "roughed in" at the time of purchase? 5, Did the realtor or builder inform you that you would have to enlarge.the existing sewer system if you finished the basement bedroom(s)? o 8. 9. Who was the home purchased from? 'If on a public water supply, do you always have an adequate supply of water?___~_ ~-~ Is the pressure always adequate? y~ Who was the builder? ~~ ~ ~-.~ '~/~.~ ~ OTHER COMMENTS: Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 Certificate of On -Site Systems Approval Parcel I.D.015-341-64 Expiration Date: ! lO —202,q- 1. 2 0 2,`I 1. GENERAL INFORMATION: Complete legal description _ Valli Vue Estates 92; Block 3, Lot 11A Location (site address) 6442 Lone Tree Circle *Anchorage, AK Current Property owner(s) Mary Bettis Day phone 244-6585 Mailing address Real Estate Agent Pam Bowerman Day phone 350-9664 2. TYPE OF DWELLING: M Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) . 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual M Individual Water Storage ❑ Holding Tank ❑ Community Class Well M Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ Waiver Fee $ Date of Payment Date of Payment Receipt Number Receipt Number COSA # O S C 2 21 0 V7 Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm: Gamess Engineerinq Group, Ltd (GEG) Phone: 907-337-6179 Address: 3701 East Tudor Road, Suite 101- Anchorage, Alaska 99507 j Engineer's Printed Name: Jeffrey A. Garness Date: In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system In accordance with the guidelines and regulations established by the Municipality of Anchorage and �q"��•. industry practices. The reported results describe the condition of the system/s on the date/s of the Separation distances �? ,�� evaluation. were measured to readily identifiable features. Hidden defects or •,.• , encroachments may exist that were not identified during the evaluation. The operational life of all wells and septic systems depend upon a variety of variables, including but not limited to, soil conditions, %� �'• r I { groundwater levels (that may Fluctuate during the year), quality of construction (materials and s� - u " . • ... • •' • .. ..fie and the water usage of the family util¢ing the system/s. These conditions can vary, and workmanship),/ � are outside the control of. GEG. Satisfactory test results do not guarantee future performance of the '%_ systems; therefore, GEG makes no warranty (express or implied) regarding the future performance of , • • • • V-- the well or septic system. GEG makes no representation whether an alternative well or septic system I prey A. �rn 'ss: can be installed on the property in the event either of the current systems fail to perform adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG to +1, -.� —%9[.� Q�:' ) j2 perform the evaluation. Reliance upon the information provided in this report by any other person or ��1 PartY (including subsequent property Y Purchasers) is not authorized, nor will it confer any legal right esato^ whatsoever. #AECC884 6. DS SIGNATURE —C— System #1 Approved for bedrooms System #2 Approved for Disapproved Conditional approval for bedrooms \``��`\Q��\�Y OFq1,I�,��� gON-SITE _ bedrooms, with the following stoulatiorWAT E R AND rn m WAST'-V'ATER oz FKU(3KAM B ti.... Original Certificate Date: 2 _Z©ZZ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other, _A rd G 0 J P �A Legal Description: VALLI VUE ESTATES #2; BLOCK 3, LOT 11A If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA COMMUNITY WATER ❑ Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) Date of flow test for C Static wat2l;J� at beginning of test ft. B. TANK DATA Age of tank(s) 22 years Tank type/material SE°" Measured operating fluid level in septic tank 51 ❑ Standpipes/foundation cleanout per record drawing Date of pumping 1/27/22 D. ABSORPTION FIELD DATA Parcel ID: 015-341-64 Structure served by this system Well production at time oftest gpm Water storage tank vo gallons Well disinfe or coliform. test? ❑ Yes ❑ No L,;-etTiform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Date of Sample C. LIFT STATION ❑ Required maintenance comple Age of lift station s Lift station mated Commen Which system tested (date installed) 1999 Adequacy test date i16f22 ❑ ALL standpipes present per record drawing Results ❑✓ Pass For 3 bedrooms Total measured depth from grade 13.25 ft (max) Fluid depth prior to test 1 in Measured depth to pipe invert from grade 4.1 ft (min) Water added 605 gal ❑ NIA — pressurized field New depth 20 in ❑ Monitor tubes go to bottom of effective. If not, state Elapsed time 120 min p depth into effective 7.91 ❑ Code -required soil cover over field Final fluid depth 11 in ❑ System presoaked Absorption rate 450+ gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) NO date of test) *2014 Gallons introduced gallons If yes, enter date N/A Comments/Deficiencies:`PRE-SOAK PERFORMED ON 1/5/22 -PIPE FOR SEEPAGE PIT NOT FOUND, CONDITION IS UNKNOWN MOA ON-SITE DEPARTMENT (REBECA CARROLL) VERBALLY WAIVED THE REQUIREMENT TO FIND THIS PIPE ON 1/18/22. COSA Checklist yellow sheet E. SEPARATION DISTANCES COMMUNITY WATER From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ❑ Yes Community Sewer Manhole/Cleano A>-1VT *5�+ ft ❑ Yes if No ft "'(Yes if No ft Neighboring Tank > 100' ❑ Yes if No ft Privat r eptic Line > 25' ❑ Yes if No ft Absorption Field on Lot > 100' ❑ Yes if No Holding Tank > 100' ❑ Yes if No ft Neighboring Absorption Fields > Yes if No ft Animal Containment > 50' ❑ Yes if No ft Yes if No ft Community Wells > 200' R✓ Yes if No ft -- Water Service Line > 10' -- - P-11 Yes Manure/Animal Excreta Storage > 100' *** ft Co Sewer Main > 75' ❑Yes if No ft ❑ Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑ Yes if No *5�+ ft Surface Water > 100' [✓ Yes if No ft Property Line > 5' Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' Q Yes if No ft Private Wells > 100' Yes if No ft Water Main > 10' Yes if No ft Community Wells > 200' R✓ Yes if No ft -- Water Service Line > 10' -- - P-11 Yes if No *** ft -- -if septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' (1 Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑ Yes if No 3 + ft Wells on Adjacent Lots: Water Main > 10' El Yes if No ft Private Wells > 100' 0 Yes if No ft *** Water Service Line > 10' R Yes if No ft Community Wells > 200' Q Yes if No ft Surface Water > 100' 0 Yes if No ft F. ENGINEER'S COMMENTS *PER 1999 INSPECTION REPORT IN MOA RECORDS **WR#990031 (SEEPAGE PIT TO LOT LINE IS UNKNOWN) ***SEE 1999 DESIGN IN MOA RECORDS WHICH SHOWS THE ASSUMED LOCATION OF THE WATER LINE ****SEEPAGE PIT TO DECK POST SEPERATION DISTANCE IS UNKNOWN G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow sheet #AECC884 DEVELOPMENT SERVICES DEPARTMENT On -Site Water and Wastewater Section www.muni.org/onsite Septic Tank Advisory Certificate of On -Site Systems Approval #OSC 221027 Subdivision: Valli Vue Estates #2 B3 Lot 11A 907-343-7904 Fax: 343-7997 Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for this property is 22 years old. Typical replacement costs range from $9,000 to $12,000 This advisorymustbe attached to all copies of the subject Certificate of On -Site Systems Approval. This is an example of what the metal of a 20 -year-old steel tank MAY look like Mailing Address P O Bax 196650 *Anchorage, Alaska 99519 6650 *www muni org I` \ 6335 1 Lot 12 4p � Tr R=50.00 R 36.4 L=64.30 N6Do 4 5� 8 ry NIS LOT 11A / \ 0 / s� a / s, C co1 2 2.0 / - 0� 24 T to Fame House N 31.3 0 12.p l co—* co deck S-1 Lot 38A �z�' Lot 10 4eptic Iz/ fi ent �typ) c9 / Note: Asphalt & concrete location is / 41jm� approximate due to snow and ice. 0 S� 00 \ RECERTIFIED 1-10-2022 — Dy AS-BUILT NO CORNERS SET THIS DATE OF • gCgS f I hereby certify that I have performed a Mortgagee's inspection — , • in accordance with ASPLS Standards of the following t/ described property: Lot 11 A, Block 3, e /C/)' g th •�.� �, Valli Vue Estates Unit No. 2 GZ- Anchorage Recording Precinct, Alaska, and that the ��i G�. , . improvements situated thereon are within the property lines •; r and do not overlap or encroach on the property lying f� lizabeth L. Walatka•, f adjacent thereto, that no improvements on the property lying �rF • • 8036 – LS • �� adjacent thereto encroach on the premises In question and �` �Fa • , , •�o ` that there are no roadways, transmission lines or other SCALE: 1 40' t �cFESSIONA� ��► easements on said property except as indicated hereon. Dated at Anchorage, Alaska Z2— this 2nd day of June , 1974. EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED FB 74-6, 66 FRED WALATKA & ASSOCIATES, L.L.C. PLAT ARE NOT SHOWN HEREON FB 21-7, pg 39 JW 907-248-1666 Engineers and Surveyors UNLESS OTHERWISE NOTED. This drawing is a representation of conditions found at the time the mortgage location survey was performed. This document does not constitute a boundary survey and is subject to any inaccuracies that a subsequent boundary survey may disclose. The information contained on this drawing shall not be used to establish any fence. structure or other improvements. This drawing shall only be used for a single property transaction. Use of this drawing by the original client or by others at a later date without the consent of Elizabeth L. Walatka Is a violation of Federal Copyright law. Unless gross negligence is discovered, the liability extent of the preparer is limited to the amount of fees collected for services in preparation of this product. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF iNSPECTION FOR HEALTH AUTHORITY APPROVAl.. OF ON-SiTE SEWER AND WATER FACILITY 264-4720 GENERAL INFORMATION (a) Application Date ~-~o~j~L~_t~a~ .... Legal Description (include lot, block, subdivision, section, township, range) Location (address or directions) Applicant Name ~. 'Be~s Telephone: Home ~4&- ~6 Applicant Address ~ ~*~ %¢-~ ~6~1~ (b) Business (c} Applicant is (check one): Lending Institution []; Owner/builder~);~; Buyer []; Other [] (explain); (d) Lending Institution Telephone Address (e) Real Estate Company and Agent Address Telephone (f) Mail the HAA to the following address: TYPE OF RESIDENCE Single-Family ~ Multi-Family [] Other Number of Bedrooms 'T~c-e..~ _ WATER SUPPLY Individual Well [] Community ~ Public [] Note: If community well system, must have written confirmation from the State Department of Environ mental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsite ~ Public [] Community E~ Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status, Page 1 of 2 72-025¢1,84) ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION AS certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, fenctional and adequate for the number of bedrooms and type of structure indicated herein. I fu~lher verify that based on tl~e information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on~site water supply end/or wastewater disposal system is in compliance with all Municipar and State codes, ordinances, and regulations in effect on tbe date of this inspection. Name of Firm _~ ~ ~o~t~"~5~ Telephone ~&~ Lt~ Date. DHEP APPROVAL ~pproved for /.~,~-~('.D~_ bedrooms by Approved /~ _ Disapproved Terms of Conditional Approval Conditional CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. Tho Municipality of Anchorage is not responsible for errors or omiss~ons in the professional engineer's work. Page 2 ol 2 MUNICIPALITY Of ANCHORAGE DEPT, OF HEALTH & ENVIRONMENTAL PROTECTION RECEIVED A. WELL DATA MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST- FEBRUARY 1984 264-4720 Legal Description: ~..~"~ Well Classification /~' If A, B, C, D.E,C, Approved (Y/N) Well Log Present (Y/N) ----" Date Completed .... Yield "-" Total Depth ~ Cased to ~ Depth of Grouting Static Water Level ~ Pump Set At Casing Height Above Ground ~ Sanitary Seal on Casing (Y/N) Electrical Wiring in Conduit (Y/N) ..... Depression Around Wellhead (Y/N) Separation Distances from Well: To Septic/Holding Tank on Lot To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line !~ ~. Cleanout/Manhole I~ ~ Water Sample Collected by '~v~¢... Water Sample Test Results ; On Adjoining Lots I~A ; On Adjoining Lots ~. ~ To Nearest Public Sewer To Nearest Sewer Service Line on Lot ; Date Comments B. SEPTIC/HOLDING TANK DATA Date Installed Standpipes (Y/N) Depression over Tank (Y/N) Pumping/Maintenance Contract on File (Y/N) Holding Tank High-Water Alarm (Y/N) "--'-* Separation Distances from Septic/Holding Tank: To Water-Supply Well To Property Line To Water Main/Service Line Course _.t~ ¢,e~ Air-tight Caps (Y/N) Size tO~,G No. of Compartments Foundation Cleanout (Y/N) Date Last Pumped ; for ~ '~'~ Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72 026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Type of System Design ~-~ength of Field ~ ~,N Depth of Field '~ ~-%' Square Feet of Absorption Area '~'7Z)¢ Depression over Field (Y/N) I~ Results of Last Adequacy Test So--~-~.<.~.~C'~f.~ Separation Distance from Absorption Field: Gravel Bed Thickness -- Standpipes Present (Y/N) Date of Last Adequacy Test To Water-Supply Well To Building Foundation Lot To Water Main/Service Line To Property Line To Existing or Abandoned System on ; On Adjoining Lots -- To Cutbank (if present) -- To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area D. LIFT STATION ~ Dimensions //~/ ,ze,n Manho,e,Access ,V/N, Tested for ~ P~"~4~um ' ~Adequacy Test. Meets MOA Electrical Codes (Y/N)~.~~'~ ** Check Permitted Bedroom Rating Against HAA Request ** I certify thaf; I have cb~cked, ~erified, or conformed to all MOA and HAA g uid.,~_elines in effect on the date of this inspection, Signed'~~L,-~/ ~ Date_ ~,.,~ ~.0..4.4~ I~; I~ Company ~ ~~MOA NO, Receipt No. Date of Payment '~(~k¢' ~"~ Amount: $ Page 2 of 2 72-026 (11/84) July 14~ 1985 ~]1O · Mr. and Mrs. ~'].oyd Bettis 64.42 Lone Tree Circle Anchorage, Alaska 99516 ,~e£erence. Lot 11A Block 3 Valli Yue Estates Subdivision Dear Mr. and Mrs. Be-ttis: A.t your reques-t, [[ per£ormed an Adequacy Test on -the existing septic system £or the three bedroom residence at the above re£erenced location. According to the Greater Anchorage Area Borough's Inspection report £or installation o£ On-Si're Sewage ~isposal Systems at this location (8-28-74), your system consists o£ a 1000 gallon steel tank and a 20' x 23' x 13' crib. Upon arriving at the property on July 13, 1985, I obser'ved the septic system and recorded the static water le¥'els. Water was then introduced to 'the system at approximately 9.7 gallons per ~ minute. The water levels were periodically measured and recorded with respect to 'time during the £illing and subsequent absorbing period. The absorption,rate was extrapolated according to ])r. Leroy Raids paper~ "In Situ Testing o£ On-Site Sewer Systems," September, 1982. This reading was 'v'eri£ied by a return visit 24 hours later. On the date tested, this system would accept approximately ~50 gallons £or a 24 hour period and meets the Municipality o£ Anchorage requirements £or a tlmree bedroom residence. Tony ~. Barter, ~.n~ E. cc: Mu~]icipa!ity of Anchorage RILL SHEFFIELD, GOVERNOR DEPT. OF ENVIRONMENTAL CONSERVATION ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, ALASKA g9501 7'elophone: (907) Address: 274-2533 To Whom it May Concern: _~/~C~x Accordin~g to records on file in this office the _ - ~~/~ Water System is in compliance wi th the State Drinking Water Regulations Sincerely,