Loading...
HomeMy WebLinkAboutT15N R1W SEC 8 LT 15115/ 051- 151- Mayor Well Drilling Permit Number: Development Services Deportment Building Safety Division On -Site Water A Wastewater Program 4700 Brogaw, Street P.O. Box 196650 Anchorage. AK 995194650 .mmu 190n 343-7904 Pump Installation Log Parcel Identification Number. Legal Description Block Lot %5/V'thri�l�j SeGB ��l Pump Installation Date of Issue: Propey�wner Name & AddMZ -G. Boun 9114V4 Tartka Ave, av_gfak Pump Intake Depth Below Top of Wen Casing: 36 V- feet Pump Manufacturer's Nameec -�/7ehi1 McaJ Pump Model: _ 9p Pomp Size _ hp Pitless Adapter Burial Depth: /0 feet 3 Pitless Adapter Manufacturer's Name: Pitless Adapter Installer- /114 Wen Disinfected Upon cow le n? P(Y 0 No Method of Disinfection:or�h0 Comments: Pump Installer Name: k)e C Company: L./ v MallingAddress: /: Q, Bar 771236 Attention: The pump installer shall provide a pump installation log to DSD within 30 days of pump installation. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES On-Site Services Transmittal Sheet TO: The for attached paperwork has been reviewed and is being returned the following reason(s): __Discrepancy in legal description and/or owner name. __Discrepancy in number of bedrooms. __ Signature and/or stamp missing on · Show measured distances to sewers/wells, curtain drains and streams within 200 feet of proposed system. __ Replacement disposal site not shown and/or tested. __Calculation error in design. __ Show locations of all soils, percolation,or water table tests. Proposed system too deep for soil test submitted. __Topographic information missing or inadequate. __Narrative missing or inadequate. __ Additional soil/perc test needed. __ Sand filter requirements not satisfied. __Water monitoring results missing or inadequate because __ Incomplete; missing __Well log required. __Water sample unacceptable because. Please supply the necessary information and re-submit your request. Your cooperation is appreciated. Reviewer ~'Date LEA VE THIS FORM ATTACHED TO PAPERWORK /203-rev, 4/93 Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Wastewater System: U New ~Upgrade ~. ~.~ ~7/~Y~,c~.~,~k A~ ¢¢:¢; ABSORPTION FIELD ~ ?- ~ -- ~8 ~eepTrench ~ Shallow Trench D Bed ~Mound ~Other LEGAL DESCRIPTION so,.~,i.~:~. ~ GPD/Sq. FL Total Depth fr°m °riginalgrade:~' Lot: Slock: Subdiv~ion: Depth to pipe boEom from 0dginal g~de: Gravel depth beneath pipe Classification (Private, A,B,C): Total De · Cased TO: Total absorption area: Pipe material: SEPARATION DISTANCES ~s~p~i~ ~ Holding ~ S.T.E.P. From Tank Field S~ation Tank Sewer Lin~ ~, ~ Number of Compadments: LiRe Lot ,,~. /,,/ / /,~. Size in gallons: IManufacturen .ou.datJo. ,¢. ¢:~ [ __¢¢__ 'Pumpon"lovolat:.~¢levolat: I High water alarm at: Cu,ainDrain '¢/ --~ ~~-- > ''~ IEiectricallnspecti°nsped°rmedby: Remarks: BENCH MARK  A~umed Elevalion: ENGINEER'S SEAL Depadment of Health and Human Sewices approval ~N c~, and a ,rove Permit No, SW980402 Page 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 19665~ Anchorage, Alaska 99519-665@ Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report of 2 Legal Description: Lot 151 T15N R1W Sec 8 PID No.: 05115105 ~50' TH1 Undeveloped LOT 151 SCALE I"=60' All Wells + 100 foot to septic c~rea J ELEVATIONS (NOT TO SCALE) TARIKA 1000 Col A-C = 59.2' Septic 5-C = 75.7' A-D = 97.5' 8,-0 = 99.1' Well +100' Septic +50' 10/14/98 ENGINEER'S SEAL ..... ,p..' 49TH"~ "...~7,0/) ~0~".. cE_'6.6 ....'~ %~;'. .... '"L+~ Rick Mvstrom. M~, vo r Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage. Alaska 99519-6650 htip://www.ci.anchorage.ak.us August10,1999 Louis Kincaid PO BOX670013 CHUGIAK, AK99567-0013 Subject: T15NRIW SEC 8LT 151 Permit # SW980402 PID # 05115105 The subject permit #SW980402, issued by this office for a single family well and/or on-site wastewater system, is due to expire as of 10/9/99. If this is a well permit and you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If this is an on-site wastewater systm and a licensed Professional Engineer has inspected the installation, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. However a new permit can be issued free of charge for a second year if the application for the renewal is received on or before the date of expiration of the original permit for which a fee was paid. When applying for a new permit after the original permit has expired or for more than a second year, the fees are: $320.00 for an on-site wastewater permit and $120.00 for a well permit. If you have any questions, please call this office at 343-4744. Program Manager On-site Services enc: Copy of Permit MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Oct 09, 1998 Expiration Date: Oct 09, 1999 Permit Number: SW980402 Legal Description: T15N RIW SEC 8 LT 151 Design Engineer: 0024 Eagle River Engineering Services Owner Name: Mike Sauvageau Owner Address: P. O. box 671948 Chugiak, AK 99567- Parcel ID: 051-151-05 Site Address: 021421 JAYHAWK DR Lot Size: 108900 SQ. FT. Total Bedrooms: 2 Permit Bedrooms: 2 This permit is for the construction of: ~ Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( t 8AACS0 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: ] a le River En ineerln Services Louis Butera, P.E. P.O. Box 773294 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax October 9, 1998 Jim Cross, P.E. Manager, On-Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: Lot 151 T15NR1W SEC 8 Nm'rative & Permit Application Dear Mr. Cross: The proposed septic upgrade will have very limited impact on adjacent properties for the following reasons: 1. The surrounding lots are large, allowing sufficient room for septic sites. 2. Immediate neighboring septic systems are all +30' distance. 3. Reserve space is adequate, due to absorption capacity. 4. Drainage will not be affected and is not a major consideration in our design. If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. \I997\98-063-NAR.DoC Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: PERFORME ~" ' DATE .~ TOwRship, BaRge, Section: 'F/F-'// ,q! ~ ~* ~ 1 2 3 4 5 6 7 8 9 10- 11 13 14 15- 16 17 18- 19- 20- COMMENTS SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depih l0 Water After MonilorinD? iT''' ~ SITE PLAN t' I Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE ~,~ c// (m,nutes/inch) PERC HOLE DIAMETER _ TEST RUN BETWEEN ~'"3~ FTAND ~"~- FT PERFORMED BY: ~-~-~:;~' J'' I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 [Rev. 4/85J EAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 Eagle River, Alaska 99577 (907) 694-5195 ERES Proiect No.: 98-063 Calculated By: LB Date: 10/5/98 Legal: LOT 151 T15N R1WSEC 8 Single Family 2 Bedroom Dwelling TEST HOLE Deep Trench Subsurface Wastewater Disposal Field Water use at 150 gallons per bedroom Percolation rate Wastewater application rate Required absorption area Trench width (W) Gravel depth (D) 300 gallons 23.8 minutes per inch 0.6 gallons per day per square foot 500 square feet 3 feet 6 feet Required length = Required absorption area / 2 / D Required length = 500 / 2 Required length = 42 feet Total Excavation Depth = 9.0 feet / 6 98-063-CAL.xIs 5:10 PM10/5/98 Eagle River Engineering Services Louis Butera, P.E. P.O. Box 773294 (907) 694-5195 tel Eagle River, AK 99577-329d~ (907) 694-3297 fax SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM LEGAL: Lot 151 T15N R1W SEC 8 10/09/98 A. GENERAL 1. The well and septic plan are for a single family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet tile Anchorage Department of lfealtb and State Department of Environmental Conservation requirements. 4. All soil tests are advism3, to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage, Department of Environmental Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent ~nulti-family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. It is always recommended that a surveyor locate the nearest lot line position and the location of any easements. 9. Any remaining open test bole excavations shall be filled. B. SEPTIC TANK/LIFT STATION 1. Septic tank shall have a minimum capacity of 1000 gallons and be of MOA approved design. C. TRENCH 1. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom. 2. The bottom of the trench shall be level, plus or minus 1.5". 3. The total depth of the trench excavation is not to exceed 9' at any point~ 4. The sewer line is to replace the existing sewer line that leads to the existing pit. The effluent line within the trench shall be laid level within 0.03'. 5. The trench gravel is to be covered with typar fabric material. 6. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed over the leachfield. 7. The area over the trench is to be finish graded to prevent ponding of surface water runoff. 8. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. RECOMMENDED LEACHFIELD DIMENSIONS: TOTAL DEPTH -- 9' GRAVEL DEPTH = 6' under pipe, 2" over pipe TRENCH LENGTH = 42' TRENCH WIDTH = 3' SOIL RATING = 0.6 GPD/ft2 BEDROOM CAPACITY = 2 SEPTIC TANK - 1000 Twenty-font (24) hours notice required for all inspections. \1997\98q063-sp¢c.doc Undeveloped I LOT 151 Undg. eumented lreneh ..,.-20% u ON Well +100' LLJ~ ~--0'2% .e~---~. O ~Abondon to Code Septic +50' 3x¢2' ~Pi~ and Tonk (."3Z:~) TH1 [] ITreneh . /- ~ ~)'J/ ~ ~ooo oo~ / ~ L/3 ./0-2% I Septic Tonk / ] All Wells TARIXA~ ~ +100 foot to proposed ® TEST ~OU~ · MONITOR TUBE pti o SEWER CL~ANOUT se C ~reo ~ WELL -- -- - EASEMENT NO SURFACE WATER PROPOSED L~CHFIELD NO KNOWN CURTAIN DRAINS ~- EXISTING L~ACHFIELD SEPTIC UPGRADE SITE PLAN LEGAL: Lot 151 T15N R1W Sec. 8 OWNER: SAUVAGEAU ~-~.' _ o~ ~s-~e3 ~r[: ~o/s/~sI sc~[ ~,, = eo, P.O. Bo~ ?73294 EAGLE RIVER, AN. 99577 (907) 694-5195 FAX.. (907) 694-3297