HomeMy WebLinkAboutT15N R1W SEC 8 LT 15115/
051- 151-
Mayor
Well Drilling Permit Number:
Development Services Deportment
Building Safety Division
On -Site Water A Wastewater Program
4700 Brogaw, Street
P.O. Box 196650
Anchorage. AK 995194650
.mmu
190n 343-7904
Pump Installation Log
Parcel Identification Number.
Legal Description Block Lot
%5/V'thri�l�j SeGB ��l
Pump Installation
Date of Issue:
Propey�wner Name & AddMZ -G. Boun
9114V4 Tartka Ave, av_gfak
Pump Intake Depth Below Top of Wen Casing: 36 V- feet
Pump Manufacturer's Nameec -�/7ehi1 McaJ
Pump Model: _ 9p
Pomp Size _ hp
Pitless Adapter Burial Depth: /0 feet 3
Pitless Adapter Manufacturer's Name:
Pitless Adapter Installer- /114
Wen Disinfected Upon cow le n? P(Y 0 No
Method of Disinfection:or�h0
Comments:
Pump Installer Name: k)e C
Company: L./ v
MallingAddress: /: Q, Bar 771236
Attention: The pump installer shall provide a pump installation log to DSD within 30 days of pump installation.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
On-Site Services Transmittal Sheet
TO:
The
for
attached paperwork has been reviewed and is being returned
the following reason(s):
__Discrepancy in legal description and/or owner name.
__Discrepancy in number of bedrooms.
__ Signature and/or stamp missing on ·
Show measured distances to sewers/wells, curtain drains
and streams within 200 feet of proposed system.
__ Replacement disposal site not shown and/or tested.
__Calculation error in design.
__ Show locations of all soils, percolation,or water table
tests.
Proposed system too deep for soil test submitted.
__Topographic information missing or inadequate.
__Narrative missing or inadequate.
__ Additional soil/perc test needed.
__ Sand filter requirements not satisfied.
__Water monitoring results missing or inadequate because
__ Incomplete; missing
__Well log required.
__Water sample unacceptable because.
Please supply the necessary information and re-submit your
request. Your cooperation is appreciated.
Reviewer
~'Date
LEA VE THIS FORM ATTACHED TO PAPERWORK
/203-rev, 4/93
Municipality of Anchorage Page
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P,O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Wastewater System: U New ~Upgrade
~. ~.~ ~7/~Y~,c~.~,~k A~ ¢¢:¢; ABSORPTION FIELD
~ ?- ~ -- ~8 ~eepTrench ~ Shallow Trench D Bed ~Mound ~Other
LEGAL DESCRIPTION so,.~,i.~:~. ~ GPD/Sq. FL Total Depth fr°m °riginalgrade:~'
Lot: Slock: Subdiv~ion: Depth to pipe boEom from 0dginal g~de: Gravel depth beneath pipe
Classification (Private, A,B,C): Total De · Cased TO: Total absorption area: Pipe material:
SEPARATION DISTANCES ~s~p~i~ ~ Holding ~ S.T.E.P.
From Tank Field S~ation Tank Sewer Lin~ ~, ~
Number of Compadments:
LiRe Lot ,,~. /,,/ / /,~. Size in gallons: IManufacturen
.ou.datJo. ,¢. ¢:~ [ __¢¢__ 'Pumpon"lovolat:.~¢levolat: I High water alarm at:
Cu,ainDrain '¢/ --~ ~~-- > ''~ IEiectricallnspecti°nsped°rmedby:
Remarks: BENCH MARK
A~umed Elevalion:
ENGINEER'S SEAL
Depadment of Health and Human Sewices approval ~N c~,
and a ,rove
Permit No,
SW980402 Page 2
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 19665~ Anchorage, Alaska 99519-665@ Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
of 2
Legal Description: Lot 151 T15N R1W Sec 8
PID No.: 05115105
~50'
TH1
Undeveloped
LOT 151
SCALE I"=60'
All Wells
+ 100 foot
to septic c~rea J
ELEVATIONS
(NOT TO SCALE)
TARIKA
1000 Col A-C = 59.2'
Septic 5-C = 75.7'
A-D = 97.5'
8,-0 = 99.1'
Well +100'
Septic +50'
10/14/98
ENGINEER'S SEAL
.....
,p..' 49TH"~ "...~7,0/)
~0~".. cE_'6.6 ....'~
%~;'. .... '"L+~
Rick Mvstrom.
M~, vo r
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage. Alaska 99519-6650
htip://www.ci.anchorage.ak.us
August10,1999
Louis Kincaid
PO BOX670013
CHUGIAK, AK99567-0013
Subject:
T15NRIW SEC 8LT 151
Permit # SW980402 PID # 05115105
The subject permit #SW980402, issued by this office for a single family well and/or on-site
wastewater system, is due to expire as of 10/9/99.
If this is a well permit and you have drilled the well, a well log must be sent to this office
for documentation of the installation and to close the permit.
If this is an on-site wastewater systm and a licensed Professional Engineer has inspected
the installation, the original as-built inspection report must be sent to this office for review,
approval and documentation. All inspection reports must be submitted within 30 days of
construction completion.
A new permit must be obtained from this office for a well and/or on-site wastewater
system NOT installed by the expiration date. However a new permit can be issued free of
charge for a second year if the application for the renewal is received on or before the
date of expiration of the original permit for which a fee was paid.
When applying for a new permit after the original permit has expired or for more than a
second year, the fees are: $320.00 for an on-site wastewater permit and $120.00 for a well
permit.
If you have any questions, please call this office at 343-4744.
Program Manager
On-site Services
enc: Copy of Permit
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Oct 09, 1998
Expiration Date: Oct 09, 1999
Permit Number: SW980402
Legal Description: T15N RIW SEC 8 LT 151
Design Engineer: 0024 Eagle River Engineering Services
Owner Name: Mike Sauvageau
Owner Address: P. O. box 671948
Chugiak, AK 99567-
Parcel ID: 051-151-05
Site Address: 021421 JAYHAWK DR
Lot Size: 108900 SQ. FT.
Total Bedrooms: 2 Permit Bedrooms: 2
This permit is for the construction of:
~ Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( t 8AACS0 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Date:
] a le River En ineerln Services
Louis Butera, P.E.
P.O. Box 773294 (907) 694-5195 tel
Eagle River, AK 99577-3294 (907) 694-3297 fax
October 9, 1998
Jim Cross, P.E.
Manager, On-Site Services
Municipality of Anchorage
P.O. Box 196650
Anchorage, AK 99519
Re: Lot 151 T15NR1W SEC 8
Nm'rative & Permit Application
Dear Mr. Cross:
The proposed septic upgrade will have very limited impact on adjacent properties for the
following reasons:
1. The surrounding lots are large, allowing sufficient room for septic sites.
2. Immediate neighboring septic systems are all +30' distance.
3. Reserve space is adequate, due to absorption capacity.
4. Drainage will not be affected and is not a major consideration in our design.
If you have any questions please call our office at 694-5195.
Sincerely,
Louis Butera, P.E.
\I997\98-063-NAR.DoC
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
LEGAL DESCRIPTION:
PERFORME ~" '
DATE .~
TOwRship, BaRge, Section: 'F/F-'// ,q! ~ ~* ~
1
2
3
4
5
6
7
8
9
10-
11
13
14
15-
16
17
18-
19-
20-
COMMENTS
SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Depih l0 Water After
MonilorinD? iT''' ~
SITE PLAN
t' I
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE ~,~ c// (m,nutes/inch) PERC HOLE DIAMETER _
TEST RUN BETWEEN ~'"3~ FTAND ~"~- FT
PERFORMED BY: ~-~-~:;~' J'' I CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 [Rev. 4/85J
EAGLE RIVER
ENGINEERING SERVICES
P.O. Box 773294
Eagle River, Alaska 99577
(907) 694-5195
ERES Proiect No.: 98-063
Calculated By: LB
Date: 10/5/98
Legal: LOT 151 T15N R1WSEC 8
Single Family 2 Bedroom Dwelling
TEST HOLE
Deep Trench Subsurface Wastewater Disposal Field
Water use at 150 gallons per bedroom
Percolation rate
Wastewater application rate
Required absorption area
Trench width (W)
Gravel depth (D)
300 gallons
23.8 minutes per inch
0.6 gallons per day per square foot
500 square feet
3 feet
6 feet
Required length = Required absorption area / 2 / D
Required length = 500 / 2
Required length = 42 feet
Total Excavation Depth = 9.0 feet
/ 6
98-063-CAL.xIs 5:10 PM10/5/98
Eagle River Engineering Services
Louis Butera, P.E.
P.O. Box 773294 (907) 694-5195 tel
Eagle River, AK 99577-329d~ (907) 694-3297 fax
SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM
LEGAL: Lot 151 T15N R1W SEC 8
10/09/98
A. GENERAL
1. The well and septic plan are for a single family residence only.
2. The drawing and or site plan shall be a part of this specification.
3. All materials and workmanship shall meet tile Anchorage Department of lfealtb and State
Department of Environmental Conservation requirements.
4. All soil tests are advism3, to the design and are to be verified or modified in the field by the engineer.
5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet
Municipality of Anchorage, Department of Environmental Conservation requirements.
6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any
adjacent ~nulti-family wells.
7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer
approval.
8. It is always recommended that a surveyor locate the nearest lot line position and the location of any
easements.
9. Any remaining open test bole excavations shall be filled.
B. SEPTIC TANK/LIFT STATION
1. Septic tank shall have a minimum capacity of 1000 gallons and be of MOA approved design.
C. TRENCH
1. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom.
2. The bottom of the trench shall be level, plus or minus 1.5".
3. The total depth of the trench excavation is not to exceed 9' at any point~
4. The sewer line is to replace the existing sewer line that leads to the existing pit. The effluent line
within the trench shall be laid level within 0.03'.
5. The trench gravel is to be covered with typar fabric material.
6. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed
over the leachfield.
7. The area over the trench is to be finish graded to prevent ponding of surface water runoff.
8. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any
Class "C" well, or 200 feet to any community well.
RECOMMENDED LEACHFIELD DIMENSIONS:
TOTAL DEPTH -- 9' GRAVEL DEPTH = 6' under pipe, 2" over pipe
TRENCH LENGTH = 42' TRENCH WIDTH = 3'
SOIL RATING = 0.6 GPD/ft2 BEDROOM CAPACITY = 2
SEPTIC TANK - 1000
Twenty-font (24) hours notice required for all inspections.
\1997\98q063-sp¢c.doc
Undeveloped
I
LOT 151
Undg. eumented lreneh
..,.-20% u ON Well +100'
LLJ~ ~--0'2% .e~---~. O ~Abondon to Code Septic +50'
3x¢2' ~Pi~ and Tonk
(."3Z:~) TH1 [] ITreneh . /- ~ ~)'J/ ~
~ooo oo~ / ~
L/3 ./0-2%
I Septic Tonk / ]
All Wells TARIXA~ ~
+100 foot
to proposed ® TEST ~OU~
· MONITOR TUBE
pti o SEWER CL~ANOUT
se C ~reo ~ WELL
-- -- - EASEMENT
NO SURFACE WATER PROPOSED L~CHFIELD
NO KNOWN CURTAIN DRAINS ~- EXISTING L~ACHFIELD
SEPTIC UPGRADE SITE PLAN
LEGAL: Lot 151 T15N R1W Sec. 8
OWNER: SAUVAGEAU ~-~.' _
o~ ~s-~e3 ~r[: ~o/s/~sI sc~[ ~,, = eo,
P.O. Bo~ ?73294
EAGLE RIVER, AN. 99577
(907) 694-5195 FAX.. (907) 694-3297