HomeMy WebLinkAboutOUR MOUNTAIN BLK 1 LT 1Our Mountain Block 1 Lot 1 051-111-39 Municipality of Anchorage Page 1 of_3 1( DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW980046 PID Number. 05111139 Name: MM&M Contracting Wastewater System: New ❑ Upgrade Address: ABSORPTION FIELD Phone: 688-1236 No'ABreeema. D Deep Trench VS allow Trench. D Bed D Mound D Other LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: r % O .4o GPD . Fl. Lot: Block: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe 1 1. Our Mountain 3 Ft. FL Township: Range: Section: Fill added above original grade: Gravel length: '75' 1. Ft. Ft. WELL:L�New ❑Upgrade Gravel width: Number, of lines: I Distance between lines: • 5 Ft. / Ft. Classification (Private, A,B,C): Total Depth: Cased To: Total absorption area: _7%9 Pipe material: .4,57M D-3034 Private 320 FL 68 Ft. sD.Ft. x`910 Driller. Sullivan Date Drilled: 4/7/98 static Water Level: 180 Installer. w4 M Date installed: 4&1-23 'Jb Ft. GpNTZV, /NG Yield: - 20 Pump Set at:Height Casing Above Ground: TANK GPM FL 2 Ft. SEPARATION DISTANCES NSleptic OHOlding ElS.T.E.P. To Septic Lift Holding rivate Man��u{ff,,a�c�t��u��re��r.. }',y 1`ANK Capacity in gallons: IOpa From Tank StaTwn Tank Sewer Linm /'r'tr . -NA' ICompertments: welt 1ST/ I'%/i�1��MaNum water 150' rF.Wfld 1J/A t41A > 150' LIFT STATIONSize 3L) 9 A N/A I8.5' in gallons: Manufacturer.Loe "Pump on" level at "Pum level at High water alarm at: Foundation IZ 5,N/A V P Curtain ,1 n Pump MakehM Electrical Inspections performed by. Drain Remarks: t�tivc r- Toro 1011civ ;r BENCH MARK /0;1511 L1� Location and Description: - Assumed Elevation: /OA• O Ft ENGINEER'S SEAL 1n f` Y C it 0 �nn e e /a{ ° ° V I- 1P Dates:ls by: & Z $ D Inspections performed ;'•,� Z3�7 y 2nd Cvk44dk?°e°°,`,s' rr Department of Health and Human Services approval r `° 4t41tAJ1, A�tJ , d ���`t7`ii'F Reviewed and approved by. Date:17-199 72-013 (Rey, 9191) MOA 25 Page 2 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 0 Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report $� u;LEGEND 0 �• b� ,`O� SP1 Septic Pump, compartment 1 SP2 1.2 C Clean Out - MT Monitor Tube .l i Permit No. _Sw980046 Page 3 of 3 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744 On -Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LT 1, BLK 1, our Mountain Riibd. PID No.: 05111119 Cl 9 3 el 982 g2 ✓ rC3 9.70 9483 �94$ 1,000 gal 85 °° 9355. 943 septic 5 °'d°,°• absorption nk 89II2 trench e5' W 129L45'94135 bends �} 136 �M-T1 / C4 93i o np`�6o e septic .q P `nB�.e oo eOOo 895, 275 _ 960 ex fabric w/ 2" insulation EE rock e^ TH# 759- ELEVATION AS -BLT 1" = 10" LEGEND SP1 Septic Pump, compartment 1 SP2 u u u 2 C Clean Out MT Monitor Tube — SI 767 '\5 MT2 960Y / t935a 0 o0oao e ° 89-4r FROM MMM CONTRACTING PHONE NO. : 6881238. Dec. 01 1998 02:02PM P1 MT by Doc co, *a §ULLI VAN WATER WELLS P.D. BOX 070272, CHUOIAK, ALASKA 09567 • T90PHONE 688.2759 OWNER OF LAND AV Al _ 1BORE H( t n�i ADDRESS - -P LEGAL DESCRIPTION / 0 T / ...&e ntj T&AJ PERMIT NUMBERIMAL Date of Iasue„�(-- i - 91i TAX INDENTIFICATION NUMBER to wall located at approved permit location? 43"`!r',(7 No Method of Drilling:tr rotary Q cable tool Depth of Well: '? _ t P�' J_._ Casing Type .S'7t' C4 Wall Thickness inches Diameter N inches, depths _feet Liner Type: It�1.J Casing Stickup Above Ground: feet Static Water Level (from ground level): 1 T is feet Pumping Ievel;�!set after firs. pumping __gpm Recover Rate:. 010 PM Method of Teating: 1 Well Intake Opening Type: O Open End Opdplan Hole n Screened; Startfeet Stopped feet L7 Perforations Start �.__ e-4 Stopped feet Grout Type: _Volume Depth: fromfeet, to " feet Pump Intake Depth: feet Pump Size Brand Name Wall Disinfected Upon Completion? bVrCs O No Method of Dleinfectlon:C#d % (r WE M e.&!'1 ommenW -7 9 e t904,- dA et (aa y DATA ousA 1344 En .l Q n1� 6(QdJ1:c Ctrl i�1f/x 16 0 /Jit C V 4,f 06Z^0%-1 V(4.OR Y [ ,rr4 rw 4� NA�i k 64,aAc c &K&a 6&KAd 00 0" MA Munici party J, —. no, B90 Dept Health & Human servIces Driller's Name -4 to the er ATTENTIONItis the Departmentoof Healtof the h & Human property Services and/oowner to bDepartmit a copy ofof IhEnviroll mental Conrservattiiom Ma Su gaccuglty of Anchorage: Department of Environmental Conservation, MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW980046 DESIGN ENGINEER:ANDERSON ENGINEERING OWNER NAME: OWNER ADDRESS:MM&M CONTRACTING PO BOX 670495 CHUGIAK, AK 99567 PARCEL ID:05111139 LEGAL DESCRIPTION: OUR MOUNTAIN BLK 1 LT 1 LOT SIZE: 44992 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1,\' 01� PAGE 1 OF 1 DATE ISSUED: 4/01/98 EXPIRATION DATE: 4/01/99 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) . (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: 14t4it L I ISSUED BY: DATE: "I[ v(e-'Nh DATE: q. l ' y8 May 30, 1997 Municipality of Anchorage Department of Heath & Human Services 825 L Street Anchorage, AK 99502-0650 Subject: Lot 1, Block 11 Our Mountain Subdivision Septic System Design Impacts to Adjacent Properties Dear On Site Services Engineer: We hereby apply for, a permit to construct a new well and septic system on Lot 1, Block 1, Our Mountain Subdivision. 'The attached Site Plan and backup documentation identify the size and location of the new absorption bed to be constructed on the lot. It. also shows the proposed location of the new well along with the 100' protective radius. A testhole performed in the area of the new absorption trench revealed silty gravel with a percolation rate of 24 minutes per inch. A total of 750 square feet of absorptive area will be required to serve the new three bedroom home. We are proposing to place _a single 75.' Jong lateral 5' wide with 4' of gravel beneath the _.distribution pipe. The distribution pipe w i 1 be placed 2.5' below the existing'.. ground surface: Our 'investigation revealed no groundwater in Testhole'No. 1L but water at 11.26-in T.esthole No. 2. The. absorption trench is designed for groundwater at this level. No conflicts exist between the proposed location of the new septic system and the protective radii of the 'adjacent wells. `The surface of the lot slopes from southeast to northwest 'at grades varying from :6% to 10%. The surface of the ground in the ;area of the absorption trench is fairly flat. If the system is constructed as` designed the following statements can be made: 1. The system, if constructed .:,as designed', wjll have noadverse impact. on the wells in the area or those to be constructed in 'thoue . .TYUI-ANCHOBAU ENORONfOENTAI SFRVICES; tIIVISIUN MAR 19 1998. FUllmn .... ....... LOT 1, BLOCK 1, OUR MOUNTAIN SUBDIVISION L2 Go 'ot L15 t OF ljj� 6� 49TH* r� ...... ; �lii ..r:.� 6�tr ,MICHAEL E.ANDERSON : Um 4301-E C7"o 4 IK 2, �- a Iry SYSt�r� �n+Z ar AREA MAAP� iPALIYYOFANCHORAGE „,'�, "N i AI. SERVICES DIVISIRN I I SCALE 1" = 100' I MAR 1 y 1998 LOT 1, BLOCK 1, OUR MOUNTAIN SUBDIVISION DESIGN FACTORS: Three Bedroom Home Pere. Rate: 24 Min./Inch Application Rate: .6 GPD/SF SYSTEM REQUIREMENTS: 5' Wide Trench System 1,000 Gallon Septic Tank 4' Drainfleld Rock 3 Bedrooms X 150 GPD / .6 GPD/SF = 750 SF of Absorption Area 750 SF/5 LF (Width) X .5 (Red. Factor) = 75 LF Length. of Trench Therefore: Construct a 5' Wide Absorption Trench With One Lateral 75' In Length. Distribution Pipe in Trench Placed at 2.5' Below the Original Ground Surface. Mound Over Trench a Minimum of 1'. V\ll/ z � �a ECir•6'XT' 1 LE /* PVL i TYPICAL 5' WIDE TRENCH SECTION (NO SCALE) NOTE: Grade Area Over Trench to Drain Away. $$�.��� Maintain 4 Vertical Separation From Ground Water. Minimum 3' Cover Over Trench or Direct Bury Insulation. MuniAnchorage ' DEPARTMENT OFF HEALTH H 8 HUMAN SERVICES 925 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: MMPI CONTRACTING DATE LEGAL DESCRIPTION: A•.1 . 151. p� I ri'14 SI bTownship, Range, section: 00 1 1617I T"' 18 WAS GROUND WATER . r ENCOUNTERED? IF YES, AT WHAT DEPTH? Bko MMd waa AIw Monimrlll0--) S Imo. (dp7 � Ont ,9 20 PERCOLATION RATE ZT I u (mmuuwineh) PERC HOLE DIAMETER TEST RUN BETWEE7t� 3 �7i FT AND FT COMMENTS ✓, / WRra /6raS0A.'E AO �- �i OMICHAEL ............. NDERSrk e 11 PERFORMED BY.- """7 1 yyl."t" �' "�L"'- CERTIFY THAT TF/}IS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE: h 72.(= (Rev, 4/85) - ,r Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: MMM CONTRACTING E I DAT LEGAL DESCRIPTION:LI,t>I' �Lry` 1_ I I ISI 6/b Township, Range, Section: 1 -'T/cusr OL— M 9-/ 10 11 12 13 " J O/ 14 13 ohlr 16 17 18 /_ WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? 7 DnMtoW8WAkff 17 �� tAotumrit>p? Due 1,0 "�(fNra7 ivft"5E!�-1 ` v d"k 1'L'..it3�l:�.c f�= 20 ,- y „ PERCOLATION RATE �Z_ (mmutewinch) PERC HOLE DIAMETER TESTRUN /BETWEEN f FTAND FT - COMMENTS �'� aA V/ J4j w,eJ d/I°- 7 f i PERFORMED BY: �/� - i (-� �'���`�tjERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE DATE 72008 (Rev. 4/85) ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 1, BLOCK 1, OUR MOUNTAIN SUBDIVISION GENERAL: 1. The scope of this project includes furnishing and installing a new 1,000 gallon septic tank. Work also includes the construction of a new 5' wide absorption trench a total of 75' in length with 4' of drainfield rock beneath the distribution piping. The distribution piping is to be placed at 2.5' below the existing ground surface. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,000 gallon septic tank must be procured from an approved source and installed at the location shown on the Site Plan. MUNICIPALITY OP ANCUGHAo!i cNVIFIOI?!,gi:r�1TN. senvlc'i I)11/IS! P,I MAR 19 1998 nF Lot 1, Block 1, Our Mountain Subdivision May 30, 1997 Page Two 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have`a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. MUNICIPALITY OF ANCflORIIGU CNVIRO70MEN'fAI. SERVICES OIVISION MAR 19 1998 Lot 1, Block 1, Our Mountain Subdivision May 30, 1997 Page Three 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). MUNICIPALITY OF ANCHOHAW ENVIRONMENTAL SERVICES DIVISION MAR 19 1998 Lot 1, Block 1, Our Mountain Subdivision May 30, 1997 Page Four 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: A minimum of two inspections are required` by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. MUNICIPALI'T'Y % ANCHHHAU ENVIAON.MENUL SEOVICFS OPII£il;Jpd MAR 19 1998 5' WIDE ' 88' LONG-- L Il r 12 NU SEPTIC W1TH1N\ 200' Of WELL A r flE1J1 q 8' D WELL / 100' SETBACK LOT 11 I AIR UNIIEVELOPED� IDO' ETBAC "" �' �• FCO .� PROPOSED 1250 GAL L OPE D S,1.E.P. TANI( y`' % TH % % PROPOSED TRENCH (PRESSURIZED! NOTE, USE 1 1/4• PIPE 14OLE AT STRUCTURES, NO WELLS WITHIN Do HOLES SHOWN ON - --- _-._-- 200' OF SEPTIC i i /ACCD DUV WAROAN AS -BUIL] % IT IS THE -RI �J� ~ TO VERIFY E. 10' MINDISTANCES, j CONSTRUC110 I. nr 9 SEPTIC AREA N. l 77 62or1 T F( L. Parcel I.D. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING 051-111-39 1. GENERAL INFORMATION COSA# OCI 0NJC Expiration Date: Complete legal description Our Mountain, Block 1, Lot 1 Location (site address) 24515 Whaley Avenue Current Property owner(s) Adam Howell Day phone 688-7700 Mailing address 24515 Whaley Avenue, Chugiak AK Lending agency Day phone Mailing address Real Estate Agent Laura Hamilton Day phone 696-0357 Mailing Address RE/MAX of Eagle River Unless otherwise requested, COSA will be held by DSD for pickup AT 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Q Individual On-site Individual Water Storage ❑ Individual Holding Tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the infornjation obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm NorthRim Engineering Phone 694-7028 Address P.O. Box 770724 Engineer's Printed Name Steve Eng Date 5/26/09 5. DSD SIGNATURE l/ Approved for bedrooms. Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory WASTEWAt trc e. PRUUrwiv" MT Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other By: &Z 6)", Original Certificate Date: (Ray. 17A5) i Municipality of Anchorage a' • �; Development Services Department ' Building Safety Division ' On -Site Water & Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: M., mo,..+M.. CInrL , I n , Parcel ID:--osi-un-39 A. WELL DATA Well type'_P If A, B, or C provide PWSID # _ Well Log (Y/N) Y Date completed _4/7/98 Sanitary seal (YIN) Y Wires properly protected (Y/N) Y Total depth 32o ft. Cased to bs ft. Casing height (above ground) 29 in. FROM WELL LOG AT INSPECTION Date of test wni98 5/11/11 Static water level ,an ft. Well production 20 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 mL Nitrate0.27Mg/L Arsenic: 0.747g/L date of sample: 5/14/09 B. SEPTICIHOLDING TANK DATA Tank Type/Material septic/steel Tank size 10o6 gal. Number of Compartments 2 185.6 ft. 5.5 g.p.m. Other bacteria 0 colonies/100 mL Collected by: NorthRin Eng. Date installed 4/23/98 Cleanouts (YM) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 1/30/09 Pumper JR's C. ABSORPTION FIELD DATA Date installed 4/23/98 Soil rating (g.p.d.KO or fe/bdrm) 0'6 System type Trench Length 75 ft. Width 5 ft. Gravel below pipe 4 ft. Total depth _e'Sft. Eff. absorption area 750ft= Monitoring tube Y Depression over field N Date of adequacy test 5/11/09 Results (Pass/Fail) Pass Fora bedrooms Fluid depth in absorption field before test 0 in. Water added 450 gal. New deptt in. Elapsed Time: omin. Final fluid depth o in. Absorption rate >= aso 9 p d Any rejuvenation treatment (past 12 mo.) (YIN & type) unk If yes, give date D. LIFT STATION Date installed 'Pump on" level a _ in. Datum E. SEPARATION DISTANCES Size in gallons Manhole/Access (YIN)/�t�_ 'Pump off" level a _ in. High water alar el aeG t in. Cycles tes Meets alamf & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot /00 ''t" On adjacent lots /a O 1 -f" Absorption field on lot 1196 +` On adjacent lots /4'90 "e' Publicsewer main Public sewer manhole/cleanout Sewer /septic service line 2 S 't Holding tank Per Animal containment areas Manure/animal excrete storage areas 1470 1f 6/3/pQ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation rt Property line /L1 lt Absorption fields-ffl -�r Water main /,4 Water service line /p t Surface water /OD 'f Wells on adjacent lots OG 'e - SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: i Property line /0 r Building foundation 4eQ 'I Water main NlA Water Service line /D i f Surface water 14il 'f- Driveway, parking/vehicle storage, Curtain drain MA114 Wells on adjacent lots /DO F. COMMENTS w�- . 4-4, �. G. ENGINEER'S CERTIFICATION .s �� OF A 1 �f y 1 certify that I have determined through field Inspections and? �+;• ':� +d review of Municipal records that the above systems are in v • 4�7_`•� ': d ............. conformance with MOA COSA guidelines in effect on this date. r Engineer's Printed Name S T F✓E 6nf 4, -,: Steve - PIP Date �lo���Q dpi f:, tE EY56 .• yaw COSA Fee $ CNO Date of Payment 2 7 Receipt Number 03535C (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number ANALYTICA GROUP Northrim Eng Attn: Steve Eng 17237 Bear Paw Circle Eagle River, AK 99577 907-694-7028 Fax: 907-694-7026 Client Sample ID: 24515 Whaley Sampling Location: 24515 Whaley Client Project: Nonhrim Eng Sample Matrix: Aqueous COC #: Steve PWS#: Residual Chlorine: Comments: Lab#: A0905156-0IA SP-Analytica, Inc. -Anchorage 4307 Arctic Blvd. Anchorage, AK 99503 Phone: 907.258-2155 Fax: 907-258-6634 Report Date: 5/22/2009 Receipt Date: 5/14/2009 Sample Date: 5/14/2009 Sample Time: 9:00:00AM Collected By: Steve Flag Definitions: MRL = Method Reporting Limit MCL= Maximum Contaminant Limit B = Present also in Method Blank 11= Exceeds Regulatory Limit M = Matrix Interference J = Estimated Value D = Lost to Dilution •• = RL higher than MCL: target not detected TNC = Too Numerous to Count - result rejected CF = Confluent Growth - result rejected TCNG = Turbid Culture No Growth - rejected Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL MCL Method Date Date Analyst 92228 (Aqueous) - TCbyAtembFilt: Enumerat Test was conducted by: Analytica - Anchorage Bacteria, Other <MRL CFU/l00mL 1.0 5/15/20095/152009CW Total Colifomt <MRL CFU/l00mL 1.0 1 5/152009 5/152009 CW Lab#: A0905156-0IB Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL MCL Method Date Date Analyst 4500-NO3E (Aqueous) - Nitrate+Nitrite pres Test was conducted by: Analytica - Anchorage Nitrate -Nitrite as Nitrogen 0.278 mg(L 0.10 10 5222009 5222009 JQ Lab#: A0905156-0IC Analysis Method Prep Prep Analysis Parameter Result Units Flags MRL MCL Method Date Date Analyst 200.8200.8 (Aqueous) - Family Well Water I Test was conduo Arsenic 0.747 ug/L 0.15 10 200.8 Page 3 of 3 by: Analytica - Thornton 5222009 5222009 GY Parcell.D. q lZ-7/o4, Municipality of Anchorage " Development Services Department Building Safety Division On -Site Water and Wastewater Program ,,, ,T 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING 051-111-39 1. GENERAL INFORMATION COSA Otc,D1g1 Expiration Date: 7 - -27-06 Complete legal description Tnt i i Tilprlr 1 • nu r mountnin CnbdiW rIon Location (site address) 24515 Whaley Ave. Chugiak, AK Current Propertyowner(s) Emily S Jack Jones Day phone 250-7602 Mailing address Lending agency Mailing address Real Estate Agent Mailing Address PO Box 670954 Chupiak,99567 Day phone Day phone Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System 3 TYPE OF WASTEWATER DISPOSAL: {� Individual On-site 10 ❑ Individual Holding Tank ❑ ❑ Community On-site ❑ ❑ Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of Onsite Systems Approval (COSA) based only upon the representations given In paragraph 4 by an Independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions In the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my Investigation, based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) In compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. NameofFirm S IS S Engineerinp Phone -694-7.979 Address 17034 N. Eagle River Loop ate 204 Eagle River, AK 99577 Engineer's Printed Name Robert C. Conan, P E Date fob OF,-, X R08ERT C. COWAN 5."DSU 51UNAI URE -- ak'gL%reQa.)-beolof Z'`Q, RrAxrfC;In.. apPSD " Approved for 3 bedrooms. tl:l;l'• :i";;�N^ �: Disapproved. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other_ By: V7�?��✓ —r�'� 1.+!% Original Certificate Date: 'L,22- D C (Ray. 11A5) Municipality of Anchorage •°, • Development Services Department Building Safety Division ° On -Site Water & Wastewater Program ' • " 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsde (907) 343-7904 CERTIFICATE �OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: t, -T (•j `JLn Our N0C,,t 1x) 5/b Parcel ID: DS 1 39 A. WELL DATA Well typerLlygTt If A, B, or C provide PWS�I/D� # = Well Logi)_ Date completed .q.L/9$ Sanitary seal�l) ` ES Wires properly protected�l) kk'S � n Total depth 2 ft. Cased to ft. Casing height (above ground) j J F in. FROM WELL LOG AT INSPECTION Date of test t4b h6 3/6 0 6 Static water level /F� r9C91 464LXtIL tb5 , ft S e Well production 020.0 y.p.m. 9.P.m. WATER SAMPLE RESULTS: Coliform __�?_colonies/100 mL Nitrate Q mg/L Other bacteria O colonies/100 mL Arsenic: D mgA Date of sample: 2 e1 o6 Collected by: SRS '10Kee !V4v B. SEPTICIHOLDING TANK DATA ---- Tank Type/Material 5t-YfIG S%i✓EL Date installed Tank size 10 0 gal. Number of Compartments 2 Cleanout (�J) �%F4 Foundation cleanout(�H) _*b Depression over tank ((1a N0 QI� High water alarm (Y La Date of pumping 2 Pumper '?vrv%Pi"4 C. ABSORPTION FIELD DATA Date installed dzz ti/9g Soil rating (g.p.d.W or ft2Abdrm) 0. (o System type gV(W(.0 J TYLrAX14 Length —ft• - Width 5eO ft. Gravel below pipe Ne b ft. qZ *Z1[i Total depth UO l ft. Eft. absorption areaft2 Monito�ring�tube_ Depression over field Q Date of adequacy test �Q6 Resu aiq "r ' For _5_ bedrooms u Fluid depth in absorption field before test IQ in. Water added gal. New depth6 in. Elapsed Time: 9W min. Final fluid depth _Q_ in. Absorption rate >= q5o+- g•P•d• Any rejuvenation treatment (past 12 mo.) (Y& type) tud If yes, give date = D. LIFT STATION N';4 Date installed Size in gallons 'Pump on" level at —in. 'Pump off" lev — Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankflift station on tot too 14 - Absorption field on lot _ (00 r / High water alarm level at Meets alarm & circuit requirements? On adjacent tots 1 co 14 - On adjacent lots I o0 Public sewer main N A Public sewer manhole/cleanout OA - Sewer A - Sewer /septic service line WwLe - oRS f Holding lank tis 4 Animal containment areas SD !4 Manure/animal excrete storage areas /60 i SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5 // Properly line S r4 Absorption field S r� Water main NA Water service line 10 / Surface water 100 /'I" Wells on adjacent lots r e Co -I SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line /0 'It Building foundation /0 /4' Water main ION r Water Service line /0 } Surface water loo /* Driveway, parking/vehicle storage Curtain drain wcw'17 K,vcuulm Wells on adjacent lots Axy /-/ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in Conformance with MOA COSA guidelines in effect on this data. Engineer's Printed Name R d /34-"L C, Cc, JV', Date � I a i r/o C COSA Fee $ /C w-- J/ l/ t�014Z Waiver Fee $ Date of Payment - 06 Date of Payment Receipt Number / Receipt Number (Rev. 11M5) tF , CC ;aaol .r .Aa; in. Fes.." r Y: - ws-l�•� i Gle-' / `to'tJ*,�i7y' �•�, ��i'i'?-M to e'. •.. ' - • • .1�rsr�rnrrnt• I hereby certify that I have surveyed the fullowing a described property: L O r l , - e le c k. I , ' ' 4 6 Cl 1 �•-r rc v •" , Io T/ThJ RIt✓,fM� -�— •�� any ' Anchorage Recording Precinct, Alaska, and that the pro- 'A/ `to'tJ*,�i7y' �•�, ��i'i'?-M to e'. •.. ' - • • .1�rsr�rnrrnt• I hereby certify that I have surveyed the fullowing described property: L O r l , - e le c k. I , ' ' 4 6 Cl Io T/ThJ RIt✓,fM� -�— Anchorage Recording Precinct, Alaska, and that the pro- 'A/ posed improvements, as planned thereon by the builder, w+ OF G will be within the property lines and will not overlap „�, •4 .... ,y . n _ : .• ^? f-^. •'+ or encroach on the property lying adjacent thereto, that thereto �•'��•� r °''�:�' -••� �� no improvements on property lving adjacent encroach on the premises m question and that there are ' 1 a no roadways, transmission lines or other visible ease- s,� - ments on said property except as indicated. hereon. • tJ %� lei :-Vr_ « � I(7s,thems�oncihiity NOTE of tht$uildefto Dated at Eagle River, Alaska V Robert C J� ir. ��n � ;,� l No. ESO's .. �� fie the tomes u Z lfiesp�Ror� this ; }ter- day of � �sl ��dti•. , ` +'.i ta!p 4.'1 �••,,.«„ ,• -� �W rnnsGdR exi_ ROBERT C. JOHNSON SCALE: Registered Land Surveyor No. 880 -LS /p ss. \\;_ - ��L��f'!Z.: - .. r I^ o rp 'Box 456, Eagle River, Alaska -. .. �`:`►... _ - Phone 894-2543 . SCS Rct# 1060666001 Client Name S & S Engineering Project Name/H LI BI Our Mountain SD Client Sample ID LI 111 Our Mountain SD Matrix Drinking Water PN SID Sample Remarks: All Dates/rimes are Alaska Standard Time Printed Date?ime 02/17/2006 14:52 Collected Date rime 02/09/2006 12:13 Received Daterrime 02/09/2006 16:28 Technical Director Stephen C. Ede Metals by ICP/MS Arsenic ND 5-00 Microbiology Laboratory Total Coliform 0 ug/l, EP200.8 C (<-10) 02/13/06 02/15/06 TK col/100mL SM209222B A (<-I) 02/09/06 TLF Allowable Prep Analysis Parameter Results PQL Units Method Container ID Limits Date Date Init Nitratc•N ND 0.100. mg/L EPA 353.2 D (<-10) 02/10/06 JC Metals by ICP/MS Arsenic ND 5-00 Microbiology Laboratory Total Coliform 0 ug/l, EP200.8 C (<-10) 02/13/06 02/15/06 TK col/100mL SM209222B A (<-I) 02/09/06 TLF