PermitNumber: So¢¢)G 0 ~2 7 ~ PIDNumber:
Name:
A/n~ Iclrn ~ Wastewater System: G New ~ Upgrade
Address:
J No, of Bedrooms:
Phone: ~ -- ~ ~ ~ ~ ~ Deep Trench ~ Shallow Trench ~ Bed O Mound ~ Other
LEGAL DESCRIPTION so, Rating: Total Depth from original grade:
Lot: ~ Block: Subdiv~ion: ]eplh to pipe bottom Irom original grade: Gravel depth beneath pipe
Township: ~ Range: ~ Section: v Fil] added above original grade: Gravel length:
I
WELL: ~ New ~ Upgrade Gravelwidth: Numberoflines: Dist~nce between lines:
~ Ft. ~ I ~ Ft.
Classification (Private, A,B,C): Total Depth: Cased TO: Total absorption area: Pipe materiah
Driller: Date Drilled; Static Water Level: installer: Date installed:
Yield: ~ Pump Set at: ~ ( using Height Above Ground:
SEPARATION DISTANCES ~ Septic ~ Holding ~ S.T.E.P.
To Septic Absorption Lift Holding )ublic/Pdvate ~anufscturer: Capac[tyin gallons:
From Tank Field Station Tank Sewer Lines ~ ~ ~ ~ ~ ~
Well- j~, j~l - ~lOo' ~aterial: ~P] Number of Co~adments:
Sudace
wat~, >~oo' >~oo' - - LIFTSTATION ~.~.
Lot Size in gallons: ~ Manufacturer:
I
Cu~ain Pump Make& Model ~ Electrical Inspections pedormed by:
Drain -- - --
I
Remarks: TA6 %y~¢~ ~ ~.~//¢¢ BENCH MARK
Location and Descrip ion:
I Assumed Elevation:
Inspections performed by: F/~F~ %~4¢,¢~/%U~ates: 1st ~/¢/~
Department of Health and Human Se~ices approval
72-013 (Rev, 9/91 ) MOA 25
PERMIT NO: SW990076
PID NO:015-242-80
PAGE 2 OF 2
1250 GALLON
/ SEPTIC TANK
SWING TIES:
FROM: COR. "A" COR. "B"
TO:
S.T.C.O. "E" 65' 65'
S.T.C.O. "F" 73' 73'
DBL. C.O. "G" 76' 76'
D.F.C.O. "H" 106' 108'
D.F.M.T. "1" 87' 80'
D.F.C.O. "J" 83' 64'
D.F.C.O. "K" 117' 113'
D.F.M.T. %" 108' 94'
D.F.C.O. "M" 100' 75'
PLAN VIEW
SCALE: 1" = 30'
121 LONG x 5' WIDE
SOiL ABS. DRAINFIELD
W. 2' FILTER SAND +6"
GVL UNDER DIST. PIPE
LOT 2
PEREGRINE HTS.
WELL
ELEV. 83.3'
BOTTOM T.H. #2
ELEV, 78.3' ~
M.T. DRY. ~'~
F~N/kt'' GP, OUNO sUP, F ACE
85.8'
--_LEV. 85.3'
CROSS-SECTION
NOT TO SCALE
4'+ SOIL COVER
1250 GALLON
SEPTIC TANK
INV.
90.7
86.3'
LOT 2, PEREGRINE HEIGHTS
SEPTIC SYSTEM INSTALLATION
AS-BUILT INSPECTION REPORT
FLATTOP TECHNICAL SERVICES SCALE: AS NOTED
14530 ECHO STREET DRAWN BY TFM
ANCHORAGE, ALASKA 99516 OCTOBER, 1999
10//2/1999 09:53 907561180? PICTURE PERFECT PAGE
· , · :'?:'~'":' ,' ~?l ~-~
... .,.::.?~.'.:.. ~ ~
_ ~ ~.~......,~ .~. ' .. ~.~ ~w~
Wm~ ~er .... : '": ..... ~';.':~;'~: ·' '
~~. ~'......~ .: .,..:. i.:;.~.:~:.~t:~: ... · ....
~ ~ . p _ .. '..'.~.~,:? ;.".:;~ ~z,~' '.':. .
18/13/1999 09:10 9875611887 PICTURE PERFECT PAGE 81
!011711799 18: l~
.,. a ~
~TO
69 ,TO_I 03
~NCHO~GE', AK ,,
); ~(': , ).
from ~g ~,,: ~'?
..: WI~ ~O~ .....
' f~ ,';~': . .
.. ' r'~,' ~K ~IbTSTONE ARGILLITE
~ GREY ......
,~f.t ~':~ ,
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Serv/ces
On-Site Services Program
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Renewal
Date issued: Apr 30, 1999
Expiration Date: Apr 29, 2000
Permit Number: SW990076
Legal Description: PEREGRIN HEIGHTS LT 2
Design Engineer: 0019 Flattop Technical Services
Owner Name: Linda Kline
Owner Address: 5049 Vance Drive
Anchorage , AK 99508-5652
Parcel ID: 015-242-80
Site Address:
Lot Size: 84014 SQ. FT,
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AA072 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By: Date:
Issued By: Date:
Rick Mystrom,
Mayor
Municipality of Anchorage
Department of Health and Human Services
825 "L" Street
P.O. Box 196650 Anchorage, Alaska 99519-6650
http://www.ci.anchorage.ak.us
343-4744
May 29, 1998
Linda L Kline
5049 Vance Drive
Anchorage, Alaska
99508 5652
Subject: Lot 2 Peregrin Heights Subdivision
Permit #SW970106, PID #015-242-80
The subject permit, issued May 23, 1997 by this office for a
single family well and/or on-sits wastewater system, has
expired as of May 23, 1998.
A new permit must be obtained from this office for a well
and/or on-site wastewater system NOT installed by the
expiration date.
If you have drilled the well, a well log must be sent to
this office for documentation of the installation and to
close the permit.
If a licensed Professional Engineer has inspected the
installation of the on-site wastewater system, the original
as-built inspection report must be sent to this office for
review, approval and documentation. Ail inspection reports
must be submitted within 30 days of construction completion.
When applying for a new permit, the fees are: $320.00 for an
on-site wastswater permit; $120.00 for a well permit and
$440.00 for a combined on-site wastewater and well permit.
If you have any questions, plsass call this office at 343-4744.
S' rely,
Ja s Cross, P.E.
Cr
Program Managsr
On-sits Servicss
enc: Copy of Permit
cc: Flattop Tschnical Ssrvicss
PAGE
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND HUMAN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW970106
DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES
OWNER NAME:KLINE LINDA
OWNER ADDRESS:907 EAST DOWLING ROAD
ANCHORAGE, ALASKA 99518
DATE ISSUED: 5/23/97
EXPIRATION DATE:
PARCEL ID:01524280
LEGAL DESCRIPTION:
PEREGRIN HEIGHTS LT
2
LOT SIZE: 84014 (SQ. FT.)
NUMBER OF BEDROOMS: 3 THIS PERMIT: 3
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
THE ATTACHED APPROVED DESIGN.
ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.85 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
THE FOLLOWING SPECIAL PROVISIONS.
1 OF
5/23/98
1
SPECIAL PROVISIONS:
RECEIVED BY: ~/~ ~/~
DATE:
DATE:
CIVIL & ENVIRONMENTAL ENGINEERING · ENERGY CONSERVATION & ANALYSIS
TIIEODORE F. MOORE, P.E. 14530 ECHO ST.
PH: (907) 345-1355 ANCHORAGE, AI~tSKA 99516
April 30, 1997
M.O.A. DHttS
P.O. Box 19-6650
Anchorage, AK 99519
Dear Sirs:
The purpose of this letter is to provide the required design narrative in support of our application for
a permit to construct wastewater disposal facilities on Lot 2, Peregrine Heights S/D, located on Upper
Huffman Road. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed
for your review.
The proposed system will be constructed in the vicinity of test hole # 1. As can be seen from the soil
log, the native material between 7 and 11.5 feet below ground level is a silty gravelly sand with a
measured perc rate of 3 - 9 minutes per inch. Using the soil application rate of 0.8 gpd/sq. ~. specified in
the wastewater ordinance, this proposed 3 bedroom residence requires a total absorption area of (3 x
150)/0.8 = 563 square feet. The proposed design consisting of 2 parallel 57 foot long x 5 foot wide soil
absorption drainfields has a total absorption area of 570 square feet.
The topography of the lot slopes down towards the northwest at approximately 14%. Bedrock was
encountered at 12 feet in test hole #1 and at 13 feet in test hole #2 ·
The proposed project will have no significant impact on present or future water Supply and
wastewater disposal systems serving adjacent properties, nor will it have any significant impact on
reserved space-surface and subsurface, or on drainage.
Please give me a call at 345-1355 if you have any questions on this submittal.
Sincerely,
Ted Moore, P.E.
0
LOT 2
PEREGRINE HTS.
R 100,
SITE FOR
SIMILAR
REPLACEMENT
DRAINFIELDS
CONSTRUCT 2 PARALLEL
57' LONG x 5' WIDE
SOIL Al
WITH 6 IN. GRAVEL
', BELOW DIST. PIPES
',OVER 2' FILTER SAND
UPPER HUFFMAN ROAD
"" /," INSTALL
% ' iALLON
T.H. SEPTIC TANK
#1
.'" ~PROPOSED
,,3 BEDROOM
HOUSE
L
PROP.
WELL
LOT 2~ PEREGRINE HEIGHTS
PROP. WELL AND SEPTIC SYSTEM
SITE PLAN
FLATTO? TECH~r[CAL SERVICES 1 INCH = 50 FEET
14530 ECHO STREET DRAWN BY TFM
ANCHORADE, ALASKA 99516 APRIL, 1997
NOTE: THIS IS NOT A SURVEYED PLAT.
ALL LOCATIONS SHOWN ARE APPROXIMATE.
I 4 DIA. F-810 ~ I % SOIL ABSORPTION DRAINFIELDS WITH 6" SEWER
4" DIA. D-8034 DOUBLE C.O. --
W. 6" "BUMP" ~
PLAN VIEW "A" 10001NSTALLGALLON ~.~ _~~
SCALE: 1" = t0' 0"
SEPTIC TANK
MONITOR TUBE
CLEANOUT
2" GRAVEL
~-FILTER SAND
~---BOTTOM OF EXCAV.
SECTION "A - A"
SCALE: 1" = 5' - 0"
LOT 2, PEREGRINE HEIGHTS
SEPTIC SYSTEM iNSTALLATION
PLAN AND CROSS-SECTION
FLATTOP TECHNICAl. SERVICES
14530 ECHO STREET
ANCHORAGE, AK, 99516
SCAI.E: AS SHOWN
DRAWN BY: TFM
APRIL, 1997
Flattop Technical Services
14530 Echo Street, Anchorage, Al( 99516
Phone (907) 345-1355
Lot 2, Peregrine Heights S/d
Upper Hnffinan Road
Wastewater disposal system installation
Specifications
1.0 General:
1.1 The scope of the project consists of installation ora 1000 gallon septic tank which discharges
into two parallel 57 foot long x 5 foot wide soil absorption drainfields.
1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor
deviations from these drawings may be allowed or required by the engineer conducting the inspections.
All construction procedures and material specifications shall conform with Municipal and State
requirements. All separation distances shall be in conformance with Municipal requirements, unless
specifically waived.
1.3 The contractor shall be responsible to obtain any necessary utility locates, and to work around
any buried utilities.
1.4 The contractor shall provide adequate cover material and rough grading over all system
components to ensure that proper drainage is achieved after settlement and that there are no residual
depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas.
1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after
the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the
construction.
2.0 Septic Tank: ,,
·
2.1 The new 1000 gallon, 2 compartment septic tank shall be Municipally approved and shall be set
level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4"
cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type,
rigid insulation.
2.2 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The
waste line from the residence to the septic tank shall have a minimum slope of 1/4'" per foot, and the
waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot.
A cleanout shall be installed within 5 feet of the building foundation, and a double cleanout shall be
installed within 5 feet downstream of the septic tank.
3.0 Soil absorption system:
3.1 The soil absorption system shall be constructed in the vicinity of test hole #1 by excavating two
parallel 57 foot long x 5 foot wide trenches to a maximum depth of 8 feet below original ground level.
The axes of the drainfields shall run parallel to the natural contours of the land, and there shall be a
mininmm of 10 feet of undisturbed soil between the drainfields.
3.2 The bottom of the excavations within each drainfield shall be level, but due to the sloping
topography, the two drainfields will be at different elevations. Any compacted or smeared surfaces shall
be raked to allow proper infiltration. Sand for leveling or serving as filter material shall comply with
Municipal specifications.
3.3 Two feet of filter sand shall be placed in the bottom of each draitffield excavation, bringing the
elevation of the bottom of the drainfield up to no greater than 6 feet below ground surface. A total of 1.0
feet of approved sewer gravel shall be placed on top of the filter sand with the perforated distribution
pipes laid level such that the pipe inverts are no less than 0.5 feet above the bottom of the sewer gravel.
Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve.
3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on
the design drawings. The portion of the monitor tube extending through the sewer gravel shall be
perforated.
3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A minimum
of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet,
two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in
addition to the filter fabric.
3.6 The top surface of the cover material shall be raised a minimum of 6 inches higher than the
surrounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill
slopes shall be no steeper than 3:1.
3.7 Unless specifically agreed otherwise the homeowner shall be responsible for arranging to have
the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and
seed to promote rapid revegetation of all areas disturbed by the construction.
4.0 Inspections:
4.1 A minimum of 5 engineering inspections will be required during the course of the project: (1)
initial stakeout with the contractor to establish the location of the system and to discuss the plans,
specifications and construction procedures, (2) after the native material has been excavated to expose the
infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test
information, (3) after the sand filter material has been placed, (4) after the sewer gravel is in place and the
distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation
or filter fabric, and (5) after rough backfill and grading is complete. The septic tank requires one
inspection after it is set level and the piping connected, but prior to backfill. This inspection may be
incorporated with any of the above inspections.
4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in
advance to ensure the availability of the engineer.
TEST HOLE
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
Lot 2, Peregriee Heights S/D
December 19~ 1996
Lieda Klein
DEPTH
(feet)
Pt.
SM Reddisb sandy loam
GM/ML Very silty gravel
Dense, dry
Becomes softer w. depth
Indistinct transition
SM Silty gravelly sand
Not cohesive
GM Fractured rock
B.H. (Bedrock)
SLOPE
Depth to Groundwater Date
- o~oundwater 12/19/96
Monitor tube dry 12/30/96
SITE PLAN
: : : : 10% : : : :
COMMENTS:
Clock Net Time Porcomoter Net Drop
Date Reading Time (minutes) Reading (inches)
12/19 12"Presoak 27 1/2
Add water and star! 12:32:45 23 5/8
#1 12:37:45 5 21 5/8 2
Add water 12:38 _2:3 _5/8:
#2 12:43 5 21 9/16 2 1/16
Add water 12:43:20 23 5/8
#3 12:48:30 5 21 9/16 9 1!16
PERCOLATION RATE } (minutes/inch) PERC HOLE DIAMETER 6"
TEST RUN BET~/EEN 7.75 FTAND 8.25 FT
PERFORMED BY FLATFOP TECHNICAL SERVICES. I '~"'.,¢~,~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE, DATE: /"/d/ '~ 9 / .9 7
TEST HOLE# 2, .
LEGAL DESCRIPTION:
DATE PERFORMED:
PERFORMED FOR:
(feet)
1
COMMENTS:
FLATTOP TECHNICAL SERVICES
14530 ECHO ST.
ANCHORAGE, ALASKA 99516
SOILS LOG -- PERCOLATION TEST
Lot 2, Peregrir, e Heights S/D
December 19~ 1996
Linda Klein
Pt
GM/ML Very silty gravel
SM Gravelly silty sand
Variable sgam
Lenses of silty sand
Leases of gravelly sand
Fractured rock below 11'
B.H. (Bedrock)
SLOPE
Depth to Groundwater Date
No groundwater 12/19/96
Monitor tube dry 12/30/96
-: '-: -SITEPLAN
T.H.
LOT 2, PEREGRINE HEIGHTS
Clock Not Time Percomoter Not Drop
Date Reading Time (minutes) Reading , (Inches)
12/19 12" Presoak 27 3/8
Add water & start 2:13 23 7/16
#1 2:25 12 22 1 7/16
Add water 2:25:40 23 7/16
#2 2:35:40 10 23 3/16 1 ~/4
Arid water 2:36 23 9/16
#3 2:46 10 22 3/8 1.3/16
Add water 2:46:30 23 1/2 ,..
#4 2:56:40 10 22:3/8 1 1/8
PERCOLATION RATE 9 (minutes/inch) PERO HOLE DIAMETER
TEST RUN BETWEEN 8.5 FT AND 9.0 FT
PERFORMED BY FLATI-OP TECHNICAL SERVICES. I ~:~'..~.___ '~ CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: t.,,//~_..~ / ~ '7