HomeMy WebLinkAboutSKYHILLS PH 1 BLK 3 LT 7Skyhills Phase 1 Lot 7 Block 3 #011 - 122-29 Municipality of Anchorage On-Site Water and Wastewater Program •(907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Page of Permit Number: OSP181136 PID Number. 011-122-29 Dwelling: ®Single Family(SF) 0 Duplex(0) 0 Multiple(SF and/or 0) Project: ❑ New ® Upgrade Name: DAVID J. ZUKER ABSORPTION FIELD Address 0 Deep TrenchED Shallow Trench 0 Bed ❑ Mound 8233 SKYHILLS DR., ANCHORAGE, AK 99502 Phone Number of Bedrooms Soil Rating 0 Other 4 Total depth from original grade LEGAL DESCRIPTION 0.8 GPD/SF 8 Ft Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot SKYHILLS PHASE 1 3 7 6 a 4 Ft. Township Fill added above original grade Gravel length Range Section Varies 4.7 - 6.5 Ft. 75 Ft. Gravel width Beds.Number of Lines Distance between lines SEPARATION DISTANCES 5+ Ft, Ft. To; Septic Absorption I NA NA Lift Station ' Holding I Sewer Total absorption area Number of trenches Dist between trenches From Tank Field Tank Line 750 Fe Wall -- 200'+ __ TANK ®Septic 0 S.T.E.P. 0 Holding 0 Other Ft. Manufacturer Capacity Surface Water : -- 100'+ -- ' NA I EXISTING Gal. Material of compartments Lot Line • -- 1 0'+ -- NA • 1NumberFoundation __ __ NAj NAUFT STATION Curtain Drain i -- Manufacturer I"50'+ , I NA f Capacity 1 1 Gal. NA Remarks *None known.Diverter added. Extensive p I Pump on level at i Limp off level at High water alarm at fill over original and secondary fields. in.!! in in. Pump make and model (Electrical Inspections performed by Installer A+ Services PIPE MATERIAL House to tank 3034 Tank to drainr id ___ Inspector ARCTERRA Drainfield 3034 GorMT 8034 BENCH MARK (Assumed elevation) 100 ft Inspection 1N 6/18/18 Location and description dates. 2�a 6/18/18 3`0 6/19118 4"6/19/18 Bottom of door sill COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL En in Conditional Approval: Date / �� OF ALS� ___ ____ _•____ / X 4 9`rH /* '7* 0 #�t KtNN.'H M. DU;,Pr4.. 1111� ,f c.- ____ Date�c —22"( �,� e. �`,i Approve A •".ssiolp Inspection Re �'�►.',w'.►.•► ap port_9-1-12.doc ears Stam • AS-BUILT SYSTEM DETAILS/SITE PLAN Permit ❑SP181136 SKYHILLS PH LOT 7 BLK 3 PIU# 011-122-29 F..�__. j._ .� j 48, �7 �' ZJg g2 .__.._i • .ter vi si . hun i t • ti �.1^ �1 -is 11/ pti, ii • �� I ' t �j J" ��•��Q` {.OJf 011/E47E� J t � ; IC ' A °1-7 �_�C�O-_CO f ! 1 t 1 NEW nap j 1N 1'73 6• ^,t F'! CQ T' .71".---'47=7:----- -.�- j �l/ CO3i , + I y y-i,Z.O / / 'i MTt I ' THtOS 14 • E 1 N k' EXISTING 1250-GAL CO jiMi t Pi./ SEPTIC TANK r h EXISTING 'EXTENSIVE FILL 1 t j + -�2G.7 l a•�/- FROMW '-.--•r CRiG.GRADE V c.0 i LW "t lin_ ' SCALE, 1' = 30' A-C=99.5' ti B-C=110,5' A-D=98,711 , ig ig i 1 gi 1 i A-E=76.1' 0 92.14 FINAL GRADE 93.9 87.4•! 1 WOK LRAM B-E=80.2' ra.T01 rune -.—.4.1- --_Gni . Guo-,;w►T 1 1 0-7 n A-F=91,4' 9 —EXISTING B-f`=74.0' SEPTIC 83.4•! 8 3.4 1 A-G=90,2' TANK i; B-G=72,3' /(22,13) SEWER ROCK • 4' 79.4 46°`d'`�.Nk 75 69,4* 104 Air `�� �F � PREPARED FOR! SCALES NTS /e<S • DAVID J. ZUKER �C� 5 4 - 8233 SKYHILLS DRIVE ti t" k E 4* •4 g H 9' r , * ANCHORAGE, AK 99502 `µo ��� r�� I' 907-865-6406 C� XENNET'FI /LI'D' • •� FIELDBOOKSpoy f11531I• C1;-711 evHDutri �• • BOUNDARYDH�wct 8MW 11511P,41011 k �, ,,,f;,, Aiir cava STAKING alEamKMD m ` i I „dirA) xsaula HOLT Dm 6 21 18 '� • �/� ,1ti'E' �.�',► �.�. Dwa ruE tau: SW2222 '�- ���NV mac cif t AaD rum FILE roe Ho. 18-1 59 "r'y�" t/tTING • 1 6•� • Ak 89577 Municipality of Anchorage Page 1 o! 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW990155 __ PIDNumber:---011-122-29 %me: .... ! Wastewater System: ~New [] Upgrade The Petersen Group ~ddress~820 Lake Otis Pkwy., Suite 204 ABSORPTION FI[:LD -- I No, of Bedrooms: Phone: 5 62-1170 Four ~ Deep Trench [3 Shallow Trench E] Bed [] Mound [3 Other Total Depth from original grade: LEGAL, DESCRIPTION Sci, Rating: , 8 GPD/Sq. Ft. 1 _ _~u~c[~v~sion: gepth to pipe bottom from original grade: Gravel depth beneath pipe ~'ot: 7 Block: 3 Skynl±±s, No. 1 4 I Ft. 8 I Ft. -- Section: Township: Range; Fill added above original grade: Gravel length: 2 ' 4 i Ft. 5 0 i Ft. WELL: [] New [] Upgrade Grave]width; 3 ' Number of lines:l Distancet~tweenlines:_ Ft Ft. ~lassification (Private, A,B.C): Total Depth: Cased TO: Total absorption area: Pipe material: City Water Ft. Ft. 800 SO. Ft ASTM D3034 PVC ~riller; Date Drilled: StaticWater Level: Installer: Date installed: Ft. Kincaid & Son 12/lr2/99 Yield: GPM PumPSetat: Ft, CaslngHeightAboveGroUndFt. TANK SEPARATION DISTANCES ]~eptic D Holding [3 S.T.E.P. TO Septic Absorption Lilt Holding Public/Private Manufacturer: Capacity in gallons: From Tank Field Station Tank SewerLine$ Anohora,~'e r~a~tk I ¢. 250 Material: Number of Comparlments: Wel~ >100' >100' N/A N/A >25' Steel Two s~aoe >~00' >~00' N/A N/A N/A LIFT STATION - N/A Water Lot > 5 ' > 1 0 ' N/A N/A N/A Sizein gagons: [Manufacturer: Line I Foundation > 5 ' > 10 ' N /A N / A N / A "Pump on" level at: off" at: High water alarm Curtain None ~]oted Dn Lot PumpMake&M0del Electricallnspectlons pedormed by: Drain Remarks: BENCH MARK Location and Description: Top of First Floor Assumed Elevation: 1 0 0 . 0 Inspections performed by: HEA Dates: lsL12/1 /99_ Department of Health and l;luman Services approval Reviewed and approved by: Date' ,~ --¢ --¢¢ 73-013 (Rev. 9/9~) MOA 25 Municipality of Anchorage Page 2 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICFS DIVISION P,O. Box 196650 Anchorage, AK 99519-6650 343-4744 On-Site Wastewater Disposal System or Well Inspection Report Permit Number SW990155 'SKYHILLS DRIVE PI[) No. 011-122-29 L= 124.93' 20' GAS & TRAIL ESMT. PLAN ' SCALE 1" = 3C R=770.00' Municipality of Anchorage Page 3 of 3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMFNTAL SERVICES DIVISION P.O, Box 196650 Anchorage, AK 99519-6650 343-4744 On-Site Wastewater Disposal System or Well Inspection Report Permit Number SW990155 PID No. 011-122-29 93.3 17' 24' 81 .6 / 87.4 Geotextile Fabric D~a~lnfield Rock ~-~ ~ ,66.0 50' PROFILIE AS-BUILT HORIZONTAL SCALE 1" = 10' NO VERTICAL SCALE ~ 81 .5 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Sarvices Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Jun 18, 1999 Expiration Date: Jun 17, 2000 Permit Number: SW990155 Legal Description: SKYHIt. LS PH 1 BLK 3 LT 7 Design Engineer: 0014 Anderson Engineering Owner Name: The Paterson Group Owner Address: 3820 Lake Otis Parkway, Suite 204 Anchorage, AK 99508- Parcel ID: 011-122-29 Site Address: Lot Size: 40817 SQ. FT. Total Bedreoms: 4 Permit Bedrooms: 4 This permit is for the construction of: [~ Disposal Field ~_~ Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage Ali construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. June 14. 1999 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 7, Block 3, Sky Hills Subdivision Septic System Design Impacts to Adjacent Pr'operties Dear Onsite Services Engineer: The owners of Lot 7, Block 3, Sky Hills Subdivision intend to construct a four bedroom home on the lot at the location shown on the attached Site Plan. We are therefore requesting a permit to construct a septic system on the lot to serve the house. The subdivision is served by the Municipal water system so a well permit is unnecessary. The attached site plan and backup documentation describe the proposed system and the location of the new system. The testholes placed on the lot revealed poorly graded sands with some silt. Percolation rates ranged from 8 to 12 minutes per inch. No groundwater was encountered during excavation and none was noted during the monitoring period. We have therefore designed a deep absorption trench with 8' of gravel beneath the distribution pipe. ']-he trench will be 50' long, 3' wide and have a total depth of 11.5' from the original ground surface. The ground surface of the lot slopes from west to east at rates from 8% to 10%. The absorption trench will be constructed across the slope toward the northeast corner of the lot to provide sufficient fall from the house for gravity flow. All lots in the subdivision are served by the water system and no conflicts exist between any septic systems currently under construction or planned for the future. Lot 7, Block 3, Sky Hills Subdivision June 14, 1999 Page Two If the 1. system is constructed as designed the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments SkyHills Subdivision Test Hole Locations HANKS SUBD. 2C K]NCA]D HI~IGHTS --~ .... ~1 11 10 9 JOHNSTON SUBD. THIS PROJECT' ~-~ 5 4 .+_ ....... -~ ]H-102 TH-6g TH-70 0 4E KINC&ID ACRES 4D TH-94 t0 PO m~4o 11 19 TH-90 t ~I'H - 1 0 _AREA__M___A__P_ SCALE 1" = 200' UNSUBDIV~DEB / Service Bedroom 50' Long X 3' Wide X 8' Effective Depth Absorption Trench · 1,250 Gallon Septic Tan~'~ ernate Site TH105 si'rE PLAN SCALE 1" = 40' LOT 7, BLOCK 3, SKY HILLS DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom System Perc. Rate: 6 - 12 Min./Inch Application Rate: .8 GPD/SF 4 Bedrooms X 150 GPD / ,8 GPD/SF 750 SF/16 SF/ LF of Trench = 46.9 Deep Trench System 1,250 Gal. Septic Tank 8' Drainfield Rock = 750 SF of Absorption Area LF Trench Length Therefore: Construct a Deep Absorption Trench System With One Lateral 50' in Length with 8' of Drainfield Rock Beneath the Lateral. Distribution Pipe in Trench Placed at 3.5' Below the Original Ground Surface. Total Depth to be 11.5' from Original Ground. Natural. 3' Backfill Geotextile Fabric 6" 4" Perforated PVC (Slots Down) nfield Rock 3 t NOTE: TYPICAL DEEP TRFNCH SECTION (NO SCALE) ,,;?% Grade Area Over Trench to Drain Away. Minimum 4' From Groundwater. Maintain 10' Separation From Lot Line. Municipality o! Ancho~ge D=._.PARTM£NT OF HEALTH & HUMAN S--]:{VIC~S 825 "L" Street. Anchora9e, At~sk~ 99502-0650 SOILS LOG' -- pERCOLATION TEST FORt. L B Construction DATE LEGAL DE$CRiPTION:___Lot 7, Block 3r Sky Hills Subdivi. sion ' SLOPE OG/Ot, 3 4 5 6 7 8 9 10 11 12 13 14 15- 16 18 19 20 ML sP/sM SITE PLAN TH ~105 Perc. wAS GROUND wATER ENCOUNTERED? IF YES, AT WHAT DEPTH? I d,'o/ D~ch ~o pSRCOLATION RATE -- / ~".. (rmnut~',nc~) P.SRO HOLE DIAMk--~ER ~" TE~T RUN BETWEEN --' ~' - FT AND ~ _ FT Cavity presoaked prior to tes__ting. ~~/~=R~tFY THAT TH/iS TI-~T WAS pERFORMED pERFORMED BY: ,_ I Michael E. Anderson '~ /~ ~ ACCORDANCE. VCtTH ALL S;AI'E ;,ND MUNICIPAL GUIDELINSS IN £FFFC7 ON Ti-~t$ DATE- DATr" Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: L H Construction LT ~l BLK 9, .Sky_ Hills Subdivision DATE PER FORtV SLOPE SiTE PLAN 1 3- 4 5 6 7- 8 9 10 11 13 14 15- 16 17 18 19- 20 WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT ~ DEPTH? P~ Depth m Waler klter~!~ cavity was '1 Date Gross Net Depth to Net Reading Time Time Water Drop PERCOLATION RATE L~ ' 0 (minutes/tach) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND ~resoaAe~ COMMENTS ~J~.~"I~RTI F Y T HAT THiS T EST WAS P ERF OR MED IN PERFOsMEDBY'~'~/:~/~ ' ~[icbsel ~ Anderson ~/~/~ ACCORDANCE WITH ALL STATE AND MUNiCiPAL GUIDELtNES iN EFFECT ON THIS DATE DATE: ~ ON-SITE WASTEWATER DISPOSAL SYSTEIVI CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 7, BLOCK 3, SKY HILLS SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,250 gallon septic tank. It also includes the construction of a new ,50' long x 3' wide x 8' effective depth absorption trench at the location shown on the attached Site Plan. Distribution piping will be placed at 3' below the surface. The total depth of the trench will be 11.5' below existing ground. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors nstalling wastewater disposal systems must be certified by the Municipal Department of Health and Human Serwces for system installations. Owners installing their own systems rnust receive prior approval from [:).H.H.S. before beginning system installation. SEPTIC 1. TANK INSTALLATION The 1,250 gallon septic tank must be procured from an approved source and installed at the location shown on the plans. Lot 7, Block 3, Sky Hills Subdivision June 14, 1999 Page 2 2. A septic tank is to be constructed by a certified manufacturer. Construction shall include two for pumping access. septic tank 4" cleanouts 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Lot 7, Block 3, Sky Hills Subdivision June 14, 1999 Page 3 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: Septic tanks must be constructed by a Municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). Insulation shall be at least 2" thick extruded direct polystyrene (Dow Chemical Co. Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted watertight couplings (Caulder, Fernco, or equal). burial with A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. Lot 7, Block 3, Sky Hills Subdivision June 14, 1999 Page 4 INSPFCTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any graveL. A septic tank may be set in place, but may not be backfilled. ThE; second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. • EfC).1" Municipality of Anchorage Q* On-Site Water and Wastewater Program a G£; IMaF (907) 343-7904 eo° S A A E T Y CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 011-122-29 Expiration Date: 9- i q_/ 7 1. GENERAL INFORMATION Complete legal description SKYHILLS PHASE 1, BLOCK 3, LOT 7 Location (site address) 8233 SKYHILLS DRIVE,ANCHORAGE,AK 99502 Current Property owner(s) DAVID J.ZUKER Day phone Mailing address 8233 SKYHILLS DRIVE,ANCHORAGE,AK 99502 Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 TYPE OF WASTEWATER DISPOSAL: 4. TYPE OF WATER SUPPLY: Individual Individual Well ❑ Holding Tank ❑ Individual Water Storage ❑ Community 0 Community Class Well ❑ Public Sewer ❑ Public Water System WaiverNariance request for: Distance: Received by: �-� Date: —Z C-/ COSA to be release a eggtfieer,unless otherwise requested by the engineer. COSA Fee $ cG l Waiver Fee $ Date of Payment (o'Z 1 *--( g Date of Payment Receipt Number Receipt Number COSA# OSC. ( 71 2CLC Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING,INC. Phone 868-3791 Address 20441 PTARMIGAN BLVD.,EAGLE RIVER,AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 6/20/18 THIS COSA DOCUMENT CANNOT BE USED TO TRANSFER TITLE UNLESS ALL VENDORS(ENGINEERING,SURVEYING,CONTRACTORS,ETC...ASSOCIATED WITH THIS COSA ARE PAID IN FULL AT OR BEFORE CLOSING. Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseenASP- �+�\ encroachments,deficiencies or discrepancies exist. OF ALS (s�� /* .,gam * # 6. DSD SIGNATURE System#1 Approved for if bedrooms. 4 .p, KENNET71M. Dui s ) / System#2 Approved for bedrooms. , ,���P/GG �i Disapproved. Conditional approval for bedrooms, with the following sttippl� ons: ON-SITE • WATER AND c" WASTEWATER c PROGRAM U By: �� (� l— Original Certificate Date: Cr,2-2_ qg The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 10-10-12.doc If more than 1 septic system is on the lot: COSA Checklist# of_ Structure served by this system _ Certificate of On-Site Systems Approval Checklist Legal Description: SKYHILLS PHASE 1, BLOCK 3, LOT 7 Parcel ID: 011-122-29 A. WELL DATA-PUBLIC WATER Well type If A, B, or C provide PWSID # Well Log (Y/N) Date completed_ Sanitary seal (Y/N)Y Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height(above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production _ g.p.m. _ g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate —mg/L Arsenic: ug/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEEPTIC/STEEL Date installed 1212/1999 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N Date of pumping 5-17-2018 Pumper McDONALD'S C. ABSORPTION FIELD DATA Date installed 6/18/2018 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.8 System type SHALLOW TRENCH Length 75 ft. Width 5'+ ft. Gravel below pipe 4 ft. Total depth 14.5 ft. Eff. absorption area 750 ft2 Monitoring tube Y Depression over field N Date of adequacy test NA-NEW FIELD Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test__in. Water added _gal. New depth, in. Elapsed Time: min. Final fluid depth in. Absorption rate >= d. 9-P. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at _in. "Pump off' level at in. High water alarm level at in. DatumCycles tested Meets alarm &circuit requirements?__ E. SEPARATION DISTANCES - PUBLIC WATER WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer/septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 200'+ ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water Service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain 50'+(NONE KNOWN) Wells on adjacent lots 200'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. AirOF AL \ Engineer's Printed Name KENNETH M.DUFFUS �� ���1 Date 6120/2018 * 4* � Ai P� [�NNET7�D � COSA canary sheet_2-6-15.doc , sT% G�<'� Ar A' ``�� I / 0ui N 80 / I 48' 47" W 236.62 Nt U n J ;P 1 �JA �F p P q41 I i 1 _4 ----1 I 1,' 11 '` 2ND LEVEL DECK e 3 RD LEVEL DECK ° I A. 3 �` . , �P o 0 // ,0) Ass'fikr a ./�� I . j , 0i' N c Z I ° a. il 0 / i I- �1 W C/J! J " Q N Th �1 W ) I W N I F ' 2:2 U in ▪ Q • i W ▪ - 1 • LJ ILI I o °O l j o8 N 0. d1 (/)1 , Q Y LDIL.1 In I m o 1 .. 2 1 ti 0 j I s i 4 ! 1 " I N8402' 34" W256.66 I I AS-BUILT SURVEY 1 " = 30 ' NO CORNERS SET THIS DATE 0000pppp ''''' OF ALN I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY .. SURVEY ORDERED BY o � DAR WALDEN @ OF THE FOLLOWING DESCRIBED PROPERTY v�P� 0_.'Qs�Q KELLER WILLIAMS LOT 7, BLOCK 3, SKYHILLS SUB. PHASE 1 ( PLAT 99-54) c/).- .49 TH .XVOA JUNE 6, 2018 ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE g S' "&i—1 VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN �'�, 4(!� ,;,-p -, THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SNOW ANY THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS O°� CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AMD/OR EASEMENTS; AND IS EXIST OTHER THAN NOTED. QA a SHANE A.HOLT ,e�O NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. VQa LS-6914 • • JkO EASEMENTS OF RECORD, OTHER THAN THOSE APPEARING ON THE RECORD PLAT , ARE NOT SHOWN DATED AT ANCHORAGE,ALASKA THIS 21 St DAY OF ��� HEREON I UNLESS INDICATED) 40 a 0 NOTE: FENCELINES THAT MAT APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERNME JUNE , 2018 AA'O/ORSIOM3S Loo PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. 40ppp0��0 ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. HOLT LAND SURVEYING 9309 GROVER DRIVE ANCHORAGE,AK 99507 13924, FB 188-52,189-1 345-5513 MUNICIPALITY OF ANCHORAGF. DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 995'19-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 01 _ 22- 9 HAA# H/9 1. GENERAL INFORMATION Complete legal description Lot 7, Block 3, Skyhills Subdivision Phase 1 Location (site address or directions) Skyhills Drive Propedy owner __The Petersen Group, Day phone 562-1170 Mailing address 3820 Lake Otis Parkway, Suite 204 Anchorage, AK 99508 Lending agency Mailin..g address Day phone. Agent Day phone _ Address Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual welt Community well Public water NOTE: Four (4) XXX If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. · ~ TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: XXX If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. ?2-O25(Rev. 1/91) Front MOA#21 o STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances and. ['egulations in effect on the.(~at~ of th!s, ji~spection. Name of Firm Anderson Engineering Phone 522-7773 Address P.O. Box 240773 Anchorage, AK 99524 Engineer's signature ~~--~' ~ Date 2/22/00 DHHS SIGNATURE ,~ Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments 'The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to pu rchassrs of homes and their lending institutions in order to satisfy certain federal and state req uirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors Or omissions in the professional engineer's work. RECEIV[D FEB Municlpahty of Anchorage ........... Environmental Services Diwsion 825 L Street, Room 502 · Anchorage, Alaska 99501 ° (907) 343-474.4 Health Authority Approval Checklist Legal Descriptien:__Lot 7, Block 3, Skyhills No. 1 Parcel I.D.: 011-122-29 A. WELLDATA - Municipal Water Sys~.em Well type If A, B, or C, attach ADEC letter. ADEO water system number Log present (Y/NJ Date completed Total depth Cased to Sanitary seal (Y/N) [-"ROM WELL LOG Date of test Static water level Well production g.p.m. W,~TER SAMPLE RESULTS: Coliform Nitrate _ Date of sample: Collected by: B. SEPTIC/HOLDING TAN K DATA Date installed 1 2 / 1 / 9 9 Foundation cleanout (Y/N) Date of Pumping New C, ABSORPTION FIELD DATA Date installed 1 2 / 2/. 9 Soil rating (g,p.d./ff~ or fta/bdrm) .8 Length 5 0.~_' _Width 3 ' Gravel thickness below pipe. Effective absorption area 8 0 0 SF Monitoring Tube present (Y/N) Y Date of adequacy test _~.C.o_a~sJ:_._ Results (Pass/Fail) Fluid depth in absorption field before test (in.); Fluid deoth (ins) Minutes later: Peroxide treatment (past 12 months) (Y/N) _ N Casing height (above ground) Wires properly pretected (Y/N) AT INSPECTION g.p.m, __ Other bacteria Tanksize 1,250 Number of Compartments 2 Cleanouts (Y/N) .... Y Depression (Y/N} N High water alarm (Y/N) N Pumper Construction Y Immediately after. Absorption rate = If yes, give date System type Deep Trench 8 ' ___Total depth 14 ' Depression over field [Y/N) __ For gal. water added (in,): .g.p.d. N bedrcoms 72-026 (Rev. 3/96)* D. LIFT STATION - None on Lot Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested E, SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Size in gallons "Pump on" level at* *Datum "Pump off" level at*. Manic'it)al Water On adjacent lots On adjacent lots System Public sewer main Public sewer manhole/cleanout Sewer/septic service line Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation > 5 ' Property line > 5 ' Absorption field > 5 ' Water main/service line > 10 ' Sudace water/drainage > 100 ' Wells on adjacent lots > SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOTTO: Property line > 10 ' Building foundation > 10 ' Water main/service line Surface water > 100 ' Driveway, parking/vehicle storage area > 2 Curtain drain None Noted (3n Lcd- Wells on adjacent lots >100' F. ENGINEER'S CERTIFICATION I certify that I have determined thru field inspections and review in conformance with MOA HAA guidelines in effect on this date. Signature ~ ~ ~ Engineer's Name Michael E. Anderson, P, E. Date 2/22/00 HAA Fee $ gate of Payment Receipt Number 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number