HomeMy WebLinkAboutSOUTH HILLS BLK 1 LT 2South Hills Lot 2 Block 1 #017-063..08 Municipality of Anchorage Page 1 o~_4 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O, Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number:_ ~W990178 PIDNumber:~017-063-08 Name: Andy & Janet Copping Wastewater System: O New [~Upgrade ^ddress~301 Hillside Way Anch., AK 9951 ABSORPTION,_ FIELD I No. of Bedrooms: Phone: 522--8747 Four ( 4 ) ~Deep Trench [] Shallow Trench E] Bed E] Mound O Other ~ Total Depth from original grade: LEGAL DESCRIPTION Sol[Rating:1 . 2 GPD/Sq. Ft. 11 . 5 Subdivision: )eplh to pipe bogota from origis~l grade: Gravel depth beneath pipe Lot: 2 Block: 1 South Hills 4 o 5 FL 7. 0 F~. Township: I Range: I Section: Fill added above original grade: Gravel length: · 5 Fb 4 0 Ft. WELL: ~ [] New [] Upgrade 3 F~. 1I - FL Classification (Private, A,B,C): Total Depth: Cased To: Total absorplion area: Pipe matefiak Existing Ft. Ff. 500 SQ. Ft. ASTM D3034 PVC __ Ff. Gold Star Const. 10/2-4/99 Yi'~eld: IPump Set at ICasing Heigld AbOve Gr°ur~d: TANK SEPARATION DISTANCES ~Septic [] Holding [] S.T.E.P. From Tank Field Station Tank SewerLirms Anchoraqe Tank 1 r 250 Well- > 100 ' > 100 ' N/A N/A- ~,,~; Material:SteAl Numberof Compartments:2 -- Surtace >100' >~oo' N/A ~/A N/A LIFT STATION - N/A Water -- Lot > .5 ~ > 1 0 I N/A N/A N/A Skein gallons: IManutacturer: Line I :oundation >5' >10' N/A N/A N/A "Pump on" level al: "Pump off" level at: High water alarm at: Curtain Drain None oted )n Lot. I {emarks: Old Septic Tank and Absorpti¢ n BENCH MARK Crib Were Pumped, Crushed and Back- Concrete Slab 1 flO-0 Ft. -, - EN~[NEEI~S~EAL Department ot He~all.h and/)--luman Serwces approval 72-D13 (Rev. 919 I) MOA 25 Permit No. SW990178 Page 2 of 4 Municipality of Anchorage DFPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519--6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: Lot 2, BLK 1, 40' Well South Hills Subd, PIDNo.: 017-0~ I Alternate Sitel 4 BR: Hsd. 1 3-08 1~250 Gal. septic tank I 1 ! PLAN AS-BUILTi / SCALE 1" = 40' Way Peri'nil No. SW990178 Page 3 of 4 Municipality of Anchorage . DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION .P.O.'Box 196650 · Anchorage, Alaska 99519-6650 · TelePhone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Legal Description: LT 2, BLK 1, South Hills Subd. PID No.: --01 7-063-08 MT geotextile C5 f~b~ic septic rock PROFILE AS-BUILT' SCALE 1" = '10' (HORIZONTAL) NO VERTICAL SCALE Permit No. SW990178 Page 4 of 4 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Sire Wastewater Disposal System and/or Well Inspection Report Legal Description:. LT 2, BLK 1, South Hills Subd. PIDNo.: 017-063-08 40 LF x 7' E.D. x 3' W - ~ 1,250 Gallon ' septic tank 2o~ "'| 91 9 S~ .l I 9--i 34~ · ' 1, 8 SYSTIEM SWING TIES NO SCALE Oi'-Z4-O0 08:25 FROJ&CTE ENVIRON~NTAL ~IK CT &E I~nv,ronn, en,a, Se tv ices Inc. 5615301 T-348 P.OI/02 F-BiT CT&E Ref.~ Client Name Project Client Sample ID M~trix Ordered By PWSID 1000247001 Anderson Engineering LoT 2, Blk I, Sovth Hills Lo~2, Blk I, Soa~ Hills Drh~klng Wat~' 0 Sample Client PO~t Prin[{:fl Dale/Time 01 f24/2000 8:22 CollectedDnteO2ime 01/20/2000 8:45 Received Date/Time 01/20/200o 9:15 Technical DirectOr Stephen C, £de Released BY~~~ ~ATER$ ~EPT 0.58~ 0.500 ~O/g EPA 300,D Allowable Prep AnatyM~ LimiTs Date Dace Ini: (<10) 01/20/2000 Ol/mo/mooo scl. NICRO LAB Total Coltfnrln Ol/2O/2OOO aPT Received Time Jan,24, 8:30AM FROM : DI.~MOND MASONRY INC F~X NO. : 907 522 6562 Jan. 18 2000 08:44~M P2 Cus'rok, m-'a AMOUNT TOTAL MATE~At. TOTAL Thank You ... 61G NA-OJ P,~ Received Time Jan,18, 8:36AM MUNICIPALITY OF ANCHORAGE Department of Health end Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 /2 ON-SiTE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Jul 07, 1999 Expiration Date: Jul 06, 2000 Permit Number: SW990178 Legal Description: SOUTH HILLS BLK 1 LT 2 Design Engineer: 0014 Anderson Engineering Owner Name: David Ma[em Owner Address: PO Box 113243 ANCHORAGE, AK 99511-0000 Parcel ID: 017-063-08 Total Bedrooms: 4 Site Address: 007301 HILLSIDE WAY Lot Size: 72000 SQ. FT. Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Date: 7- 7-?? 522 7773 522 6779 (FAX) ! ANCF!ORAGE, AK 99524 i~Vl~,ot~ENT^~ SE~V,C[~S roves,oh, MEMORANDUM DATE: .July 2, 1999 RECEIVEI TO: Dan Roth dUI_ 7 1999 FROM: Mike Anderson, P.E. ~ ~--~'/"' Murdcipality u, ,-, . Oept. Health & Hun~an SUBJECT: Lot 2, Block 1, South Hills Subdivision Septic System Design Revision We recently completed a cross section of Lot 2, Block 1, South Hills Subdivision to determine the difference in elevation between the location of LeRoy Reid's test hole from 1980 and those completed during our field investigation. It is difficult to determine the exact location of his hole, but it appears to have been in close proximity to the existing absorption crib. The difference in elevation between Test Hole No. 1 and Reid's Test Hole is 5.5'. This could explain the difference in groundwater levels between the holes. In addition, the Reid Test Hole is shown fairly close to the absorption crib and what is noted as groundwater could actually be effluent from the crib. Mr. P, eid's test hole shows the water level right at the ML layer. This layer could be holding the groundwater in place causing a perched water table. Our test holes revealed clean sands and gravels with no evidence of any silt layers. Soils encountered were very absorbent allowing water to easily pass. Test Hole No. 1 is now totally dry with no evidence of groundwater in either hole. We have added the replacement absorption trench to the site plan and have also noted the existing septic tank and absorption crib must be pumped, crushed and backfilled during construction of the new system. Hopefully, this will resolve your issues with the design and permit application and the permit can now be issued. Thank you for your assistance with this matter. OLD RABBIT CREEK ROAD NOTE: Existing Septic Tank and j Absorption Crib %o be pumped crushed and back~illed, v · 't Bedroom LOT 2 ~ome LOT NOTE:~ No conflicts with ~xisting wells and otic systems. 40' Long X 7' Effe Absorptio ~H2 250 Gallo )tic Tank :ive Depth Trench LOT 1 SITE PLAN SCALE 1" = 40' HILLSIDE WAY' 'ITl ANDERSON ENGINEERING P.O, Box 240773 ANCHORAGE, AK 99524 (907) 563-7155 SHEET NO. OF CALCULAT~ D 8Y OATE sc,,,.~4x-d-:/"---.,,,' ~%../'~-~' June 22, 1999 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 2, Block 1, South Hills Subdivision Septic System Design Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 2, Block 1, South Hills Subdivision intends to construct a four bedroom home on the lot. A septic system is currently in place on the lot that served a house which was destroyed by fire. A new system must therefore be constructed to serve the new house. The attached site plan and backup documentation describe the proposed system and the location of the existing well. The testholes placed on the lot revealed poorly graded gravel underlain by silty sand. Both lenses percolated at rates between 1 and 5 minutes per inch. Groundwater was encountered during excavation in Testhole No. 1 at a depth of 16.5'. The water stabilized at 15.8' during the ensuing monitoring period. We have therefore designed a deep absorption trench with 7' of gravel beneath the distribution pipe. The distribution pipe will be placed at 3.5' below the surface and the total depth will be 10.5'. The existing septic tank will be pumped, crushed, backfilled and abandoned in place. .,, The ground surface of the lot slopes from the east to the west at shallow grades and from south to north at much steeper grades. The absorption trench will be placed in an area with a slope of 3%. The trench will be constructed perpendicular to the slope in accordance with Municipal criteria. Lot 2, Block 1, South Hills Subdivision June 22, 1999 PageTwo If the 1. system is constructed as designed the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments OLD RABBIT CREI:"K ROAD NOTE: Existing Septic Tank and Absorption Crib ~o be pumpe~, crushed and back~illed. ~/~/ · . · ~~ 40' Long Absorptio NOTE :k Four Bedroom LOT 2 {ome ~H2 250 Gallo )tic Tank No conflicts with ~xisting wells and 3hic systems. LOT SITE PLAN SCALE 1" = 40' LO'[' 2, BLOCK 1, SOUTH HILLS DI--SIGN FACTORS: SYSTFM REQUIREMENTS: Four Bedroom System Deep Trench System Perc. Rate: 3 MinJInch 1,250 Gal. Septic Tank Application Rate: 1.2 GPD/SF 7' Drainfield Rock 4 Bedrooms X 150 GPD / 1.2 GPD/SF = 500 SF of Absorption Area 500 SF/16 SF/ LF of Trench = 35.7 LF Trench Length Therefore: Construct a Deep Absorption Trench System With One Lateral 40' in Length with 7' of Drainfield Rock Beneath the Lateral. Distribution Pipe in Trench Placed at 3.5' Below the Original Ground Surface. Total Depth to be 10.5' from Original Ground. Natural ~3' Backfill Geotextile Fabric 6" 7 4" Perforated PVC (Slots Down Drainfield Rock NOTE: TYPICAL DEEP TRENCH SECTION (NO SCALE) Grade Area Over Trench to [)rain Away. Minimum 4' From Groundwater. Maintain 10' Separation From Lot Line. Municipality of Anchorage. DEPARTMENT OF HEALTH & HUMAN SERVICFS 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: The Real Estate Company DATE PERFORMED LEGAL DESCRIPTION: Lr~ 2 / BLK 1 ~ Township, Range, Section: South Hills Subd. SLOPE SITE PLAN 1 7 8 9- 12 13 14 15 16 17 18 19- 20- COMMENTS WAS GROUND WATER ENCOUNTERED? S DEPTH? p E Depthlo Water Alter ~ / . / / Reading Date Time Time Water Drop Teskho]e presoaked prior to PERCOLATION RATE ~ TEST RUN BE'rWEEN "* test __ (minules/inch) PERC HOLE DIAMETER ~? L~ FT AND ¢ ~ FT Percolation test on SM material 3.5 minut:aa par inch_ ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Municipality of Anchorage. DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: The Real Estate Company DATE PERFORMED LEGAL DESCRIPTION: LT 2, BLK 1 t South Hills Subd. 3 13- 14- 15- 16 17 18 19 20 COMMENTS Township, Range. Section: SLOPE WAS GROUND WATER ' t[ ENCOUNTERED? · DEPTH? E SITE PLAN Gross Net Oepth to Net Reading Date Time Time Water Drop IJ PERCOLATION RATE '~ (mioules/inch) PERC HOLE DIAMEI.ER (f~' ~ TEST RUN BETWEEN FT AND -- FT Testhole presoaked prior to test. ACCORDANCE WITH ALL SI'ATE AND MUNICIPAL GUIDELINES IN EFFECT ON THiS DATE. DATE: ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 2, BLOCK 1, SOUTH HILLS SUBDIVISION GENERAL,: The scope of this project includes the procurement and placement of a new 1,250 gallen septic tank. It also includes the construction of a new 40' long x 3' wide x 7' effective depth absorption trench at the location shown on the attached Site Plan. The existing septic tank must be pumped, crushed, backfilled and abandoned in place. Total depth of the trench is 10.5' with the distribution pipe placed at 3.5' below the surface. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 'The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systerns must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION The 1,250 gallon septic tank must be procured from an approved source and installed at the location shown on the plans. Lot 2, Block 1, South Hills June 22, 1999 Page 2 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3.-I'he septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Lot 2, Block 1, South Hills June 22, 1999 Page 3 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATFRIAL SPFCIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). A permeable geotextile be installed between native soil layer. fabric (Typar, Mirafi or equal) must the final drain rock layer and the 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. Lot 2, Block 1, South Hills June 22, 1999 Page 4 INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of aprofessional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field construction notes for use in preparing the of the completed system. survey layout and certified as-built MUNICIPALITY OF ANCHORAGE ,/~ Department ~ Health and Environmenta? ~rotection 825 ,~ Street, Anchorage, AK. .,9501 264-4720 * * * HANDWRITTEN PERMIT * * * Permit ~ ~D~I ~ W~_-L-L--~ftDTLOR ON-SITE SI--WER PERMIT Phone Number: App:Lic ant: Location: Legal Description: ~'Q, ~CC~ /~L ~ / Type of Soil Absorption System Is: Trench: Drainfield: Seepage Bed: Maximum Number Lot Size: of Bedrooms: Holding Tank: Soil Rating(sq.ft/br) The Required Size of the Soil Absorption System Is: DEPTH <~ LENGTH ¢¢"- GRAVEL DEPTH __ ~ WIDTH The length dimension is the length(in feet) of the trench or drainfield. The depth of a trench or pit is the distance between the surface of the ground and the bottom of the excavation(in feet). There is no set width for trenches. The gravel depth is the minimum depth of gravel between the outfall pipe and the bottom of the excavation(in feet). * * REQUIRED SEPTIC(HQC-ErTNG) TANK SIZE =--~_3/~ .~ GALLONS * * Permit applicant has the responsibility to inform this department during the installation inspections of any wells adjacent to this property and the number of residences that the well will serve. * * * TWO(2) INSPECTIONS ARE REQUIRED Backfilling of any system without final inspection and approval by this department will be subject to prosecution. Minimum distance between a well and any on-site sewage disposal system is 100 feet for a private well or 150 to 200 feet from a public well depending upon the type of public well. Minimum distance from a private well to a private sewer line is 25 feet and to a community sewer line is 75 feet. Well logs are required and must be returned to this department within 30 days of the well completion. Other requirements may apply. Specifications and construction diagrams are available to insure proper installation. * * * PERMIT EXPIRES DECEMBER 1 9 8 3 * * * I certify that: (1) I am familiar with the requirements for on-site sewers and wells as set forth by the Municipality of Anchorage. (2) I will install the system in accordance with codes. (3) I understand that the on-site sewer system may require enlargement if the residence is remodeled to include more that 3 bedrooms. Signe~: A~DU(~~ ~ ~'A~,/~(~ .... Issued by: pplicant Date: SOILS LOG MUNICIPAI. ITY OF ANCHORAGE DEPARTMFNT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch 6-650, Anchorage, Alaska 99502 ~.76-222~ SOILS LOG - PERCOLATION TEST [] PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: 1 SLOPE SITE PLAN 10 11 15- 16 17 18 19 2O WAS GROUND WATER ENCOUNTERED? DEPTH? Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE TEST RUN BETWEEN (minutes/inch) FT AND. FT CERT,P,EO B~: ~~-~':,' DATE: ~0'-'~--~ 72-008 (7/76) OAAB-HD.I Gl,, I'I-'R ANCHORAGE AREA BOROL DEPAFITMEI~T OF ENVlROBIME~ITAL QUALITY 3500 TUDOr( r(OAD ANCHOr(AGE, ALASKA ggB07 27g-8§86 iNSPECTiON REPORT ON-SITE SEWAGE DISPOSAl. SYSTEM SEPTIC TANK: DISTANCE FROM WELL__ LIQUID CAPACITY ADDRESS ..... PHONE ,6;/1 Z .COMPARTMENTS. GALLONS. INSIDE LENGTH_ INSIDE WIDTH. LIQUID DEPTH__ SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS_ ___/ OUTSIDE DIAMETER_ L, ,NO NEAREST LOT LINE_ Z~')'/~ A: D,STANCE PROM WELL , LENGTH_ ~ ., DEPTH , BUILDING FOUNDATION TOTAL EFFECTIVE ABSORPTION AREA (WALL AREA) SO, FT. TILl-- DRAIN FIELD: TOTAL LENGTH DISTANCE FROM WELl /-~---~-FOUNDATION---- . NEAREST LOT LINB__ , OF LI~E'~/ , NUMBER OF LINES / DISTAN~LINES TRENCH WIDTH__ / IN. TOTAl. EFFECTIVE ABSORPTION A~R~ SQ. FT. LENGTH OF DEPTH: TOP OF TILE TO FINISH GRADE___ .DEPTH OF FILTER MATERiAl BENEATH TILE~ .iN. ABOVE TILE , BUILDING FOUNDATION.__ ~i~/ WATER WELL: TypE~_l,/ji.rTi) DEPTH_ '//0 ' DISTANCE FROM . I --SAMPLE~J¢-~O~--, NEAREST NEAREST ~ SEPTIC (//~ SEEPAGE /',/.2,~,/ __- OTHER LOT LINE '~)/7/~ ~/~ , SEWER LiNE . TANK_ , SYSTEM_____~ '~'~.~ , CESSPOOL , SOURCES DIAGRAM OF SYSTEM GREATER ANCHORAGE AREA L ItEALTH DEPARTMENT 327 Eagle St. Anchorage, Alaska 99501. 279-2511 RESIDENCE ADDRESS~-~r/~/~ /~T&- / ~X LOCATION OF INSTALLATION LEGAL DESCRIPTION [/~'~' ~- Z~O~' ~ ,:)o/__~/'/L~- ~-~',/~ APPLICATION TO INSTALL: SEPTIC TANK_ .~ __-, SEEPAGE PIT ~'__.,DRAIN FIELO_ ,OTHER. TO SERVE THE FOLLOWING FACILITY FINANCED THROUGH PERCOLATION TEST RESULTS TO BE INSTALLED BY._ ANTICIPATED DATE OF GOMPLETION. BELOW TO BE FILLED OUT BY HEALTH DEPARTMENT THIS ~S 'r0 SERVE AS-~. L~:~/20 y , PERMIT T0 INSTAkk A AS DESCRIBED BELOW, SIZE OF UNIT TO BESERVEI] . SEPTIC TANK 81ZE Z(--0~) ~ _TYPE __ SEEPAGE //0 / L/''Z)7- /4 DIAGRI Z... - DISTANCES: ,O/f. Hoalth Authoritg I certify that I am familiar with the requkements of Greater Anchorage Area~h Ordinance No. 28-68 and that the above described s~tem is in accordance with said code. ~/~~~ dREATER ANCHORAGE AREA BOROUGH tiEALTN DEPARTMENT CASE 327 EAGLE STREET ANCHORAGE, ALASKA 99501 Papfomraed Fora L~'al Description: Lot 2 Block/ 5uDQ~vxsxon ,)~f///9 ~/// This Fomm Repomts Depth Feet Soll Characteristics Location Sketch if Yes At ~,,at Depth Re adin,9., { Date G~oss Time r~rop ~sed ' ~'~ [~stallal'~on: Seepage Net Time Depth To H20 Drain Field Net Drop Depth Of inlet COMMEN £~. Test Performed Bs,:.~.f ', ...... August 16, 1971 8ed~or, d Avenue Alask8 Sub~ect: Lot 2, Block 1. Sou:hht11 Subdivision In revtet~Hng our 1970 files, we have discovered that yo~ received a ftf)al 'Inspe(:8lert Em said sy:item prior to Lacbfill. If this cesspool shall be backftlled without the permission of ~he health authority. All persons shall contact the Health Department gtvtn~ ]'e an effort to e~llevtate this sttuatioe, this offic~ requests that you send or bring to our office, ~.lithtn 15 (lays from receipt of ti)is letter, data convetni~g the sewer system. This data should be tn the fo~m of receipts for backfill, septic tank, c~tb, percolation test, excavation work, etc., nlonu with detailed d~a~Hng of the system. If such eecetpt~ have bee~)midlatd. a), tnspocto)' ObS~)PVe what he can of your systef~ a.d discuss wi th you. ),'1~, however, th(s situation remains unchanged and you ~,~okt', ))o effort to comply with Borougit regulations, this office will be forced to t~eat your sewage system ~ ae illegal ~yst~m and ~)tar. t cot~rt p~oceedtngs. If you have any qeestions concerning the above, please feel free to call this office for assistance. Sincerely, Tim Rumfolt .Sanitarian 825 "L" STREET ANCHORAGE, ALASKA 99501 (90?) 264-4111 GEORGE M. SLILLIVAN, MAYOR DI_:PARTMEN] OF IIEALTH AND ENVIRONMEN I'AL PROTECTION October 10, 1980 Wally/Edith Bedford % Judie Rowland Century 2]. - Sleeper, Inc. 8050 Old Seward Highway Anchorage, Alaska 99502 Subject: Lot 2 Block I South Hills Subdivision The adequacy test performed on the subject property's sewer system has failed. Therefore, an upgrade will be necessary. Prior to the upgrade, a soils test must be obtained so that a permit can be issued by this department. A listing of private soils engineers J_s enclosed. If there are any further questions, please call this department at 264-4720. Sincerely, Robert C. Pratt, R,S. Associate Specialist RCP/ljw ALASKA ENVIRONMENTAL THINKING OF THE FUI'URE SBA BOX 1584R · ANCHORAGE, ALASKA 99507 CONTROL SERVICerS MUNICIPALIq'Y OF ANCI,O~ACq' RECEIVED INSPECTION APPOINTMENTS TIME ~ \A',~Y ' [ ~ TIME T~SPECTOR INSPECTOFi INSPECTOR A~i.i~.~ ~p~ -- MUNICIP . A~MUNAUg'' MUNICIPALITY OF ANCHORAG~ DEPT. O~ 1] ,lti l &  DEPARTMENT OF HEALTH & ENVIRONMEN'rAL PROTECTI~/IRONMSqlAL ~, < i'~CTION 825 L Street - Anchorage, Alaska 99501 'r.l.phon. 264-4720 R E C E 1 V [ D REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1, Incomplete req~ests will ~ot be processed, Please allow ten (10) days for processing, 1, PROPERTY OWNER , PHONE MA~I N~ ADDRESS ~ROPERTY RESIDENT (If different from above) PHON~ 2. a~YER ' - PHONE ~A~ L~G A~DRESS ~ LENDING INSTITUTION PHONE ~AILING ADDRESS ~ RE~LTOR~AGENT: / PHONE MAILING ADDRESS '~.' LEGAL DESCRIPTION STREET LOCATION fY, lb' _ . /,~ 6. TYPE OF RESIDI.=NCE ~ SINGLE FAMILY [] MULTIPLE FAMILY NUMBER OF~BEDROOMS [] One [] Four [] Two [] Five E~_ Three [] Six [] Other 7. WATER SUPPLY I~ INDIVIDUAL* *ATTACH WELL LOG. A well log is required for all wells drilled [] COMMUNITY since June 1975. For wells drilled prior to that date, give well [] PUBLIC UTI LITY depth (attach log if available.) 8. SEWAGE DISPOSAL SYSTEM "~ INDIVIDUAL/ON-SITE" /?~ ? YEAR ON-SITE SYSTEM WAS INSTAl. LED, [] PUBLIC UTI LITY NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATE[). 72-010 ,R er. 6'79)~"~ ~/ , THIS SIDE FOR OFFICIAL USE ONLY 1. TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY 2, WATER SUPPLY [] INDIVIDUAL [] COMMUNITY [] PUBLIC UTILITY Connection Verified 3, SEWAGE DISPOSAL SYSTEM [] INDIVIDUAL/ON -SITE []PUBLIC UTILITY Connection Verified []Septic Tank or []Holding Tank Size: icao~-'~ If Tank is homemade give dimensions: NUMBER OF BEDROOMS [] ONE [] THREE [] FIVE [] TWO [] FOUR [] SIX PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER [] OTHER DATE INSTALLED INSTALLER SOILS RATING TYPE OF TANK MANUFACTURER TOTAL ABSORPTION AREA 4, DISTANCES WELL TO: Absorption Area to nearest Lot Line MATERIAL Septic/Holding Tank Absorption Area \ Nearest Lot Line 5. COMMENTS 72 010 (Rev. 6/79) 1, PROPERTY OWNER Wally/Edith Bedford MUNICIPALITY OF DEPARI'MENT OF HEALTH & ENVI~ONMENTAL'PI;~TI-_'CTION Environraentai Sanitation Division 825 L Streel., Anchorage, Alaska 99~1 Telephone 21~-4720 MAILING ADDRESS 2. LEGAL DESCRIPTION Lot 2 Block 1 .lls Subdivision 3. TYPI: DWELLING SINGLE FAMILY MULTIPLE FAMILY RE E E] FHER (Describe) 4, WATER SUPPLY INDIVIDUAL COMMUNITY/PUBI_.IC 5, SEWAGE DIVI DUAL/ON-SITE LIC UTI LITY NG TANK (Maintenance Requi E3 APPROVED }R BED[ ~ CONDITIOI' {OVAL (See for a three DISAPPROVED DATE 27 , BY (TITLE) 19,,0 72-014 (3/78) ' ' 1~1 ' ' ~ e Co~dztlona~ if monies are escrow/edeCo have th existing l~ching ~rea upgraded. The/~grade would include ~ feet o~ leaching line w~Lt~ 6.feet of gravel backfill/. Prior ~o the upgarde~ permit will need to be obtained from t~is depar~m~fnt. ./ ~ % ~-.b .,~ '-~,~'"--- >-v ,~-.'~. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 01.,_0 3 08 HA^# GENERAL INFORMATION Complete'legal description . T,n~ 2; 1; ,qn.t-h Hilln Location (site address or directions) 7301 ~]].~d~ way Property owner Mailing address Lending agency Mailin. g address Agent Address Andy and ,Tnn~_h C. oppl nq Day phone 730% Hillside Way Anchorage, AK 99516 R22-R747 Day phone 'Day phone Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDFIOOMS: Four 3, TYPE OF WATER SUPPLY: Individual well Community well Public water NOTE: 4. TYPE OF wASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE-": XXX If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. -.: . XXX If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA~21 STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances,, and regulations in effect on the date of this inspection. Name of Firm And~r~n ~Ingl nme~'ing Phone 522-7773 Address P.O. Box 240773 Anchoraqe, Engineer's signature ~ ~* ~ AK 99524 Date 1/24/00 DHHS SIGNATURE ~/ Approved for 4 Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments Date The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Legal Description: A, WELL DATA Well type Log present (WN) Total depth 1 1 3 ' Sanitary seal (Y/N) RECEIVED Municipality of Anchorage dAN P-- 4 f)00 ~0/~l. ~ DE-'PARTMENT OF HEALTH & HUMAN SERVICESMuNiclP^Uf¥ or. ^NcI{ilI Environmental Services Division ~ViRO~ENTALSERVIC~ 825 L Street, Room 502 · Anchorage, Alaska !)9501 · (907) 343-4744 Health Authority Approval Checklist Lot 2, Block 1, South Hills ParcelI.D.: 017-063-08 N If A, B, or C, attach ADEC letter. ADEC water system number Date completed 8 / ? 1 __ Cased to > 4 0 ' Casing height (above ground) 2 ' Y Wires properly protected (Y/N) Y AT INSPECTION 6/2.1 /99 70' 68 FROM WELL LOG g.p.m. Date of test Static water level Well production WATER SAMPLE RESULTS:. Coliform 0 . Nitrate Date of sample: 1 / 2 0 / 0 0 B. SEPTIC/HOLDING TANK DA'IA Date installed 10/2/99 _Tanksizel~250 Foundation cleanout (Y/N) Y Date of Pumping_ NRW C. AB.~;ORPTION FIELD DATA Date installed 1 0 / 4 / 9 9 5R'~ mg/r. _ Other bacteria_ 0 Collected by: MEA Number of Compartments 2 _ Cleanouts (Y/N)_ . Depression (y/N) N High water alarm (Y/N) N Pumper C~,qn F~ f:¥'llr, t~ i r~n - _g,p,m, Y Soilrating (g,p,d./ft~orft~/bdrm)_ 1 .2 .Systemtype.Da~.p 'PrRnqh Length _ 4 0 ' Width 3 ' Gravel thickness balow pipe Effective absorption are,'~ 56 0 Monitoring Tube present (y/N) ~' Dateof adequacytest.._Ne~ Co~st. _Results(Pass/Fail) Fluid depth in absorption field before test (in,); Fluid depth (ins) Minutes later:__ Peroxide treatment (past 12 months) (Y/N) 72-026 (Flev. 3/96)* N Immediately after_ Absorption rate = If yes, give date 7 ' Total depth _ 1 2 ' . Depression over field (Y/N) _ N For .bedrooms gal. water added (in.): __ .g.p.d. N/A D. LIFT STATION - None on Lot Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: F, Septic/holding tank on lot > 1 0 0 ' Absorption field on lot > 1 0 0 ' Public sewer main N /A Sewer/septic service line > 25 ~ Size in gallons "Pump on" level at* *Datum On adjacent lots On adjacent lots Public sewer manhole/cleanout biff station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation > ,5 ' Property line ~ 5 ' Absorption field Water main/service line > 1 0 ' Surface water/drainage > 1 0 0 ' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line > 10 ' Building foundation ~ 10 ' Surface water > 100 ' Curtain drain None Noted on Lot ENGINEER'S CERTIFICATION I certify that I have determined thru field inspections and r in conformance with MOA HAA guidalin., es in effect on this date. Signature ~ ~--~,~~ Engineer's Name Michael E, Anderson, P.E. Date 1 /24/00 >5' Wells on adjacent lots "Pump off" level at* N/A >100' Water main/service line Driveway, parking/vehicle storage area > 1 Wells on adjacent lots > 100 ' HAA Fee $ -~ ~ Date of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)*