Loading...
HomeMy WebLinkAboutSTELIOES LT 3Stelioes Lot 3 #017-422-34 Municipality of Anchorage Page 1~o! _3 DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVlRONMEN'I'AL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · TeLephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: SW980022 PtD Number: 017-422-34 Cindi Herman Wastewater System: [] New [] Upgrade Add,esS: 12730 Cardinal Circle Anc., AK 3516 ABSORPTION FIELD - Three Phone: 561 -- 0505 NO. el Bedrooms: k~Deep Trench [] Shallow Trench ~ Bed ~ Mound O Other · 6 GPD/S~ R 12 ' SteZ~oes 4 ' F~ 8 ' WELL: ~ New ~ Upgrade Gr~vel depth: 8 ' FL 1 -- C~ification (Private, A.B,C); Total Depth: Cased TO: Total sbsorphon area~ 9 6 Pipe material: Private 485' FL 20' FL SO. Ft. ASTM D3034 PVC Alpine Drilling 4/15/98 15' R. Whitters Exc. 11/4f5/98 Yield: Pump Set at: J Casing Height Abo~ Ground: 6 5 Ft.I 2' TANK G SEPARATION DISTANCES ~s~ptic ~ Holding ~ S.T.E.P. From ~ank Field Statio~ Tank Sew~Linos Anchorage Tank 1 , 000 Well > 100 ' > 100 ' N/A N/A N/A ~aterial~tee1 Number of Compa~ments; 2 s.,~o. >~oo' >~00'. N/A N/A N/A LIFT STATION - U/A Water Lot > 5 ' > 10 ' N/A N/A N/A Sizein gallons: ~ Manulacturer: Line >5' >10' N/A N/A N/A "Pump on" level at: J"Pump cfr' level at: Foundation Cu~ain None )bserv 9d on 5ot Pump Make & Model J Electrical Inspections perlormed by: Drain Remarks: BENCH MARK First Floor Slab 100.0 E~, Inspections pedormed by: A. Harala Dates: 1st 11/4/98 ~'~ Department of Health and Human Services approval PID No. 017-422-34 Permit Number SW980022 cARDINAL CIRCLE Page 2 of 3 // // // PLAN AS-BUILT SCALE 1" = 20' Municipality of Anchorage Page 3 of 3 DEPARTMENT OF HEALTH AND HUMAN SI=RVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, AK 99519-6650 343-4744 On-Site Wastewater Disposal System or Well Inspection Report Permit Number SW980022 PID No. 017-422-34 PROFILE AS-BUILT HORIZONTAL SCALE 1" = 10' NO VERTICAL SCALE OF. W.ELL · ,!iX) CATiON iSK ETcH :. ' ~s ~w M EA.SU,RED PROM: DATA: Yype and Color FI ground surface Depth From To . DATE OF C,0~LI:'I' WELL Depth of hol~: Depth of c~siog:' ft DEPTH TO STATIC WATER' LEVI:L: , ... .._~drlL~f{ boloW ~top Of casing D.'g ME'~HOD OF'DRILLING: ~ air r0t~ry [] cable.~ool' .'...';.'? ;domestic [] irr!gati0n .FI n~q~ltpn.. ;., ~] public .:(~]'othet. ' · ' .: CASING STICK,UPi. 'fL, Diem: Casing tyi3e! .. WELL INTAKE oPENING TYPE:' E~ open end ~..~ D perfernte~ ~,.open hole" · ".'.'., Depths of open~nQs: , ~ .to ..... ' [t'~' ' SCREEN TYPE Diem; ' i~.-,.- Slot/Mesh Size: ' Length: GRAVEL,PACK TYPE: ' "i. Voiume used:: ' GROtJT TYPE; Depth: f~'om ' ft to, DEVELOPMENT METE( "' ' Duration: . , PUMPING ~.EVEL'AND YIELD: ' ': ' ' ' '. hfs Pumpln~ pUMP'iNTAKE DEPTH: . . ft HorsePowe/: ;,. . WELL..DIS!NFECTED' UPON COMPLETION?' . ~ .0ON~RAC OR INFQF~I~IATION: REMARKS: ; . ...: :.' ,.: ~onzeo Hesp~entatlvo Dbte . , · 3601 C St, SUite 800 .' . . ' ,, · · ANCHORAGE AK'99503-6935- . ' ..' ~. : , " : Phone {907}269-~639,Fax {907)56.2-13B4.. .~. MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW980022 DESIGN ENGINEER:FLATTOP TECHNICAL SERVICES OWNER NAME:HERMAN CINDI A OWNER ADDRESS:12730 CARDINAL CIRCLE ANCHORAGE, AK 99516 DATE ISSUED: 2/25/98 EXPIRATION DATE: 2/25/99 PARCEL ID:01742234 LEGAL DESCRIPTION: STELIOES LT 3 LOT SIZE: 34920 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: THE ATTACHED APPROVED DESIGN. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DATE: DATE: OP TECHNICAL S CIVH~ & ENVIRONMENTAl, ENGINEERING · ENERGY CONSERVATION & ANALYSIS TIIEODORE F, MOORE, P.E. 14530 ECHO ST. PH: (907) 345-1355 ANCHORAGE, ALASKA 99516 February 10, 1998 M.O.A. DHHS P.O. Box 19-6650 Anchorage, AK 99519 Dear Sirs: The purpose of this letter is to provide the required design narrative in support of our application for a permit to construct wastewater disposal facilities on Lot 3, Stelioes S/D, located at 12730 Cardinal Court. Soils logs, perc test results, a site plan, design drawings and specifications are enclosed for your review. The proposed system will be constructed in tile vicinity of test hole # 1. As can be seen from tile soil log, the native material between 2' and 18.25' below ground level is a silty gravel with a measured perc rate of 16 minutes per inch. Using the soil application rate of 0.6 gpd/sq, fi. specified in the wastewater ordinance, this 3 bedroom residence requires a total absorption area of (3 x 150)/0.6 = 750 square feet. The proposed 55 foot long trench design with 8 feet of effective gravel depth has a total absorption area of 880 square feet. The topography of the lot in the area of the proposed construction slopes downward towards the south at 5 - i0%. Driveway construction for the house on Lot 2 to the west has resulted in the creation of a 6 foot high cut bank along the west property line, and construction of Talisman Road resulted in the creation of a 15 foot high cut bank with the top beginning near the south property line. The site for the proposed soil absorption trench will be within approximately 15 feet of the top of the cut bank along the west property line and within approximately 30 feet of the top of the cut bank along the south property line. Due to the depth of the proposed trench below the existing ground level, there is virtually no possibility that effluent in the proposed trench could daylight through either of these cut banks, and therefore your concurrence in the proposed location is requested. The site for the proposed replacement trench will be further fi'om either of these cutbanks. The proposed project will have no significant impact on present or future water supply and wastewater disposal systems serving adjacent properties, nor will it have any significant impact on reserved space-surface and subsurface, or on drainage. Please give me a call at 345-1355 if you have any questions on this submittal. Sincerely, Ted Moore, P.E. TRACTA LOT 6 LOT 2 STELIOES S/D O SEPTIC SYSTEM 5O% R 100' ® EXIST, WELL , ' × WELL HSE SEPTIC '% ~. . ' SYSTEM R 100' '% ~ -' o o WELL % / ~ LOT 4 % /' ~ STELIOES ,REPL TR. / % / ~ '~-. ~ ~ INSTALL1000 GAL ~ '1 ' T'~7~L'~- ~ SEPTIC TANK ~ , o~, T.H. = I,'" ~ ~. ~' X SOIL ABSORPTION TRENCH ] ~ ' .'" W. 8' SEWER GVL ~ELOW PIPE TALISMAN ROAD ~ LOT 3, STELIOES S/D PROP, WELL AND SEPTIC SYSTEM EXIST, WELL SITE PLAN LOT 3 ~I~ATTOP T~C~C~ Sgg~CgS 1 INCH = 50 FEET TALISMAN 14530 ACCO STEgg~ DRAWN BY TFM ", HEIGHTS S/D ~C~{O~Og, ~AS~ 995 ]6 FEBRUARY, 1998 ,, NOTE: THIS IS NOT A SURVEYED P~T. ', ALL LOCATIONS SHOWN ARE APPROXIMATE. 1000 GALLON SEPTIC TANK 55' LONG SOIL ABSORPTION TRENCH DOUBLE CLEANOUT WITH 8' SEWER GRAVEL BELOW--~ ~ "A" "~"A" --OUTER EDGE OF TRENCH EXCm-'~ PLAN VIEW SCALE: 1" = 10' CLEANOUT MONITOR TUBE 3 1 -MOUND BACKFILL 12" LTER FABRIC 0 PERF. DIST. PIPE ~--1/2" - 2 1/2" SEWER GRAVEL SECTION "A - A" SCALE: 1" = 5' BOTTOM OF EXCAVATION LOT 3, STELIOES S/D SEPTIC SYSTEM INST. PLAN AND CROSS-SECTION FLATTOP TECHNICAl. SERVICES 14530 ECHO STI~EET ANCHORAGE, AK, 99516 SCALE: AS SIIOWix! DRAWN BY: TFM FEBRUARY, 1998 Flattop Technical Servicee 14530 Echo Street, Anchorage, AK 99516 Pho,e (907) 345-1355 Lot 3, Stelioes S/D 12730 Cardinal Circle Wastewater disposal system installation Specifications 1.0 General: 1.1 The scope of the project consists of installation ora 1000 gallon septic tank followed by a 55 foot long soil absorption trench with a total of 8.5 feet of sewer gravel. 1.2 Construction shall be as depicted on the approved site plan and design drawings. Minor deviations from these drawings may be allowed or required by the engineer conducting the inspections. All construction procedures and material specifications shall conform to Municipal and State requirements. All separation distances shall be in conformance with Municipal requirements, unless specifically waived. 1.3 The contractor shall be responsible to obtain any necessat3, utility locates, and to work around any buried utilities. 1.4 The contractor shall provide adequate cover material and rough grading over all system components to ensure that proper drainage is achieved after settlement and that there are no residual depressions. Insofar as possible the contractor shall minimize damage to trees and existing lawn areas. 1.5 Unless specifically agreed otherwise, the homeowner shall be responsible for finish grading after the soil is compacted, as well as placement of topsoil and reseeding all areas disturbed by the construction. 1.6 Prior to the start of construction the property owner shall arrange for a surveyor to set survey lath marking the location of the west property line at approximately 50 and l OO feet north of the southwest property corner. To assist in positioning the well the surveyor shouhl also set lath at the PC at the northwest end of the straight portion of the property line adjacent to Cardinal Circle, as well as at pobtts along that property line $0 and l OO feet southeast of the PC. 2.0 Septic Tank: 2.1 The new 1000 gallon, 2 compartment septic tank shall be Municipally approved and shall be set level on undisturbed soil. Each compartment shall be equipped with a watertight manhole cover and a 4" cleanout. If the tank is buried less than 4 feet, it shall be insulated with 2 inches of approved burial type, rigid insulation. 2.2 All pipe connections to the tank shall be equipped with waterproof mechanical couplings. The waste line from the residence to the septic tank shall have a minimum slope of i/4'" per foot, and the waste line between the tank and the soil absorption system shall have a minimum slope of 1/8" per foot. A cleanout shall be installed within, fi"feet of the building foundation, and a double cleanout shall be installed within 5 feet downstream of the septic tank. 3.0 Soil absorption system: 3.1 The soil absorption system shall be constructed by excavating a 55 foot long trench to a depth of 12 feet below original ground level in the vicinity of test hole #1. 3.2 The bottom of the excavation shall be level. Any compacted or smeared surfaces shall be raked to allow proper infiltration. 3.3 A total of 8.5 feet of approved sewer gravel shall be placed in the bottom of the excavation with the perforated distribution pipes laid level such that the pipe inverts are no less than 8.0 feet above the bottom of the sewer gravel. Sewer gravel shall be 0.5" - 2.5" screened gravel, with less than 3% passing the #200 sieve. 3.4 Monitor tubes and cleanout pipes shall be of 4" diameter and installed in the locations shown on the design drawings. The portion of the monitor tube extending through the sewer gravel shall be perforated. 3.5 Approved filter fabric shall be placed over the entire top surface of the sewer gravel. A minimum of 2 feet of soil cover is to be placed over the filter fabric. If the soil cover thickness is less than 3 feet, two inches of rigid, burial type insulation is to be placed over the entire top surface of the gravel, in addition to the filter fabric. 3.6 The top surface of the cover material shall be raised a minimum of 12 inches higher than the sm'rounding terrain to allow for subsequent settlement, and shall be graded to smooth contours. Fill slopes shall be no steeper than 3:1. 3.7 Unless specifically agreed otherwise the homeowner shall he responsible for arranging to have the site finish graded after the backfill material has stabilized, and for placement of adequate topsoil and seed to promote rapid revegetation of all areas disturbed by the construction. 4.0 Inspections: 4.1 A minimum of 4 engineering inspections will be required during the course of the project: (i) initial stakeout with the contractor to establish the location of the system and to discuss the plans, specifications and construction procedures, (2) after the native material has been excavated to expose the infiltrative surface to ensure that it is level and at the right elevation, and conforms with the soil test information, (3) after the sewer gravel is in place and the distribution pipes have been laid and connected up to the septic tank, but prior to placement of insulation or filter fabric, and (4) after rough backfill and grading is complete. The septic tank requires one inspection after it is set level and the piping connected, but prior to backfill. This inspection may be incorporated with any of the above inspections. 4.2 The installer shall coordinate the timing of the inspections with the engineer sufficiently far in advance to ensure the availability of the engineer. ITEST HOLE FLATTOP TECHNICAL SERVICI-'S 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: __Lot 3: Stelioes ,~JD DATE PFRFORMED: ,lanuary4~, 1,qR& PERFORMED FOR: ___Cindy. He[man_ DEPTH (feet) Pt' 1 SM Reddish silty loam 5 GM/ML Gray silty gravel 6 Variable texture Lensee of damp ML 7- Lenses of dry GM SLOPE ~% '50% SiTE PLAN LOT 3 STELIOES S/D T.H. #1 66 ~#2 TALISMAN ROAD Depth to Groundwater Date No qroundwater 1/28/98 ~itnr tube,~L-y 2/4/98 COMMENTS: Date Reading Clock Net Time Percometer Net Drop Time (minutes) Reading (inches) 1/28 12" Pre-soak __ 27 3/8 _ Add water & star[ 2:13:30 23 1/2 #1 2:33:30 .2L 22 1/4 1 1/_4 Add~v_ater 2:34 23 1/2 #2 2:54 2~0~ 22 1/4 1 1/4 Add water 2;54:30 23 1/2 #3 3:14:30 2~0~ 22 I/4 1 1/4 PERCOLATION RATF 16 (minutes/inch) PI=.RC HOLE DIAMETER 6" TEST RUN BE'RNEEN 7.0 FTAND 7.5 FT Design soil absorption sy_stem on basis of 0.6 gpd/sq._ft. _______ PERFORMED BY FLA'Fi'OP TECHNICAL SERVICES. I~'¢~"'...¢.~,,.(~' '~"¥~-. CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ITEST HOLE #2 LEGAL DESCRIPTION: DATE PERFORMED: PERFORMED FOR: DEPTH (feet) 1 2 FLATTOP TECHNICAL SERVICES 14530 ECHO ST. ANCHORAGE, ALASKA 99516 SOILS LOG -- PERCOLATION TEST Lot 3, Stelioes S/D ,January. 28;Jg_g& Cindy Herman Pt. SM Reddish silty loam GM/ML Gray silty gravel Variable texture Lenses of damp ML Lenses of dry GM SLOPE 5O% ~., .~ e THEODORE F. MOORE SITE PLAN LOT 3 STELIOES S/D T.H. #1 66 ~#2 TALISMAN ROAD Depth to Groundwater Date _ No groundwater 1/28/98 ~lonitor tube dry_ 2/4/98 0% B.H. (Bedrock) Date l Reading 1~/ 12" Pre*soak Add '¢~ter~& start Add water Clock Net Time Net Drop Time (minutes) (inches) J_1;21 11:31;30 t1:32 Reading 23 1/2 5 22 1/8 2,3 9/16 5 22 1/8 23 7/16 5 _~21/16 1 3/8 1 7/16 I 3/8 PERCOLATION RATE 4 (minutes/inch) PERC HOLE DIAMETP'R __~,, TEST RUN BETWEEN 6.75 FTAND~_25_... FT COMMENTS: This perc test was conducted near the southwest side of the test hole. An earlier perc test conducted on Jan. 28 near the northwest side of the test hole at approx, the same depth perced at a rate slower than 60 min./in. Recommend 0.6 gpd/sq, ft. for avg. PERFORMED BY FLA'FFOPTECHNICALSERVICES. I ,~"...¢.,~~ CERTIFYTHATTHISTESTWASPEREORMEDIN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~- /i'D /' ~8 Scmplin9 LOG OF TEST BOHING 'tole No ~ ewit!_~m g. Lounsbur. g ( Associat~ Sheet ] of ~ DESCRIPTION Soil type, cold6 texture, e$1irneted particle slze~ sampler driving notes~ depths c/fculal/on Iost~ holes cn drilling eose~ bits used, etc. Vegetation: ,I {m~{mmmmmmmmmmmmmmmmmmmm{m~m~~{m{{ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 017-422-34 HAA# ~-~J~O 1. GENERAL. INFORMATION Complete legal description Lot 3, Stelioes Subdivision- Location (site address or directions) Talisman Road and Cardinal Property owner _~tarm~ gan ¢.on~-rllrtt~i.r~n Day phone 1720 E. 59th Avenue Anchorage, AK 99507 Mailing address Lending agency Mailing address Agent Address Day phone ~Day phone Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: NOTI=: Three (3) XXX Individual well Community well Public water If community well system, provide written confirmation from State ADEC attest- I lng to the legality and status of system. · . TYPE OF WASTEWATER DISPOSAL: Individual on-.site Holding tank Community on-site Public sewer NOTE: XXX If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structu re indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Anderson Engineerinq Address P.O. Box 240773 Anchoraqe, Engineer's signature ~ ~' ~ Phone 522-7773 AK 99524 Date 4/11/2000 DHHS SIGNATURE A?proved for ~ Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: Additional Comments The Municipality of Anchorage Department of Health and Human Sen/ices (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. RECEIVED Mu.,e,,.,i o,A.chor.,e . *PR DEPARTMENT OF HEALTH & HUMAN SERVICESk~uN~¢~P^LiW oF ^,¢~1~ Environmental Services- Division ~tW~RONME~^L SE~WCE~ 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Health Authority Approw~l Checklist Legal Description: _T.,of. 3: L~-.~I i (~R~ RuBd i Vi ~ inn Parnell.D,: 017-422-34 If A, 13, or C, attach ADEC letter. ADEC water system number Date completed 4 / 1 5 / 9 8 _ Cased to 2 0 ' Casing height (above ground) ¥ Wires 3roperly protected (Y/N) AT iNSPECTION A, WELL DATA Well type Pz:±vate Log present (Y/N) Total depth 485 ' Sanitary seal (Y/N) FROM WELL LOG 4/15/98 15' 6.5 g.p.m. Nitrate · 636 mg/ L Other bacteria Collected by:__A, Harala _ Tank size 1 , 0 0 0 Y >2~ Y Date of test Static water level Wel production WATER SAMPLE RESULTS: 0 Coliform Date of sample: _ .4/3/2000 B, SEPTIC/HOLDING TAN K DATA Date installed 11 / 4 / 98 Foundation cteanout (WN) Date of Pumping _ C. ABSORPTION FIELD DATA Date installed 11 / 5 / 98 _ Length 56 ' Width Effective absorption area 896 Number of Compartments 2 Cleanouts [Y/N) .... Depression (Y/N) N High water alarm (Y/N). ~ · Pumper .._C.,~, _ - i .... Soil rating (g.p.d./ft~ or ft~/bdrm)_ · 6 3 ' Gravel thickness below pipe Monitoring Tube present (Y/N) ¥ _ Date of adequacy test _New Consk. Results (Pass/Fail) N g.p.m. __ Immediately after. Absorption rate = .. If yes, give date Fluid depth in absorption field before test (in.); __. Fluid depth (ins) Minutes later:. Peroxide treatment (past 12 months) (Y/N) 72-026 (Rev. 3/96)* Y Sy,,~tem type .Deep T]:enc_h 8 ' _Total depth 12 ' Depression over field (Y/N) N For .bedrooms gal. water added (in.): ~.p.d. D. LIFT STATION - None on Lot Date installed Manhole/Access (Y/N) High water alarm level at* *Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot > 100 ' Absorption field on lot > 100 ' Public sewer main N/A Sewer/septic service line > 2 5 ' Size in gallons "Pump on" level at* "Pump off" level at* N/A On adjacent lots > 100 ' On adjacent lots > 100 ' Public sewer manhole/cleanout Lift station N/A >100' Absorption field > 5 ' Wells on adjacent lots SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation > 5 ' Property line >,5 ' Water main/service line > 1 0 ~ Surface water/drainage > 1 0 0 ' SEPARATION DISTANOE FROM ABSORPTION FIELD ON LOT TO: Property line > 1 0 ' Building foundation > 1 0 ' Surface water > 100 ' Curtain drain None Noted on Lot F. ENGINEER'S CERTIFICATION I certify that I have determined thru field inspections and review of Municipal in conformance with MOA HAA guidelines in effect on this date. Engineer's Name Michael E. Anderson, P.E. Date 4/11/2000~ Water main/service line > 1 0 ' Driveway, parking/vehicle storage area > 2 5 ' Wells on adjacent lots > 100 ' HAA Fee 8. ~-~ ~ / ~--'D Date of Payment /7~/,/F/~-~ Receipt Number '--~- ~ ~ ~'~-- (~ L~) Waiver Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)* 04-10-00 08:37 FROM'-¢TE ENVIRONBENTAL ~t~. CT&E EnvironmentalSe, vices Inc. 5615301 %167 P.02/03 F"284 CT&E Ref.# 100142300l Client Name Anderson Engineering Project Namcm L3 Stehnes Subd. Client Sample ID L3 STehoes Subd. Matrix Dnnking Water Ordered By PWSID o Client PO~ Printmd Date/Time 04/09/2000 21 59 Collected Date;rime 04/03/2000 13:10 Received Date/Time 04/03/2000 16:40 Technical Director Stephen C. Ede Sample Remarks: m,636 0.500 ~g/g EPA 3ofl.m (~lm) om/mm/tim To~L coliform 0 cot/lOOmL sM18 92228 04/Om/dO KAp Received Time Apr,lO, 7:39AM