ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP201353 PID Number: 051-791-09
Dwelling: ® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ® New ❑ Upgrade
Name
LUIS & FELECIA BAPTISTA
ABSORPTION FIELD -EXISTING
❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound
Site Address
22545 LAMPERT CIRCLE, CHUGIAK
❑ Other
Phone
Number of Bedrooms
Soil Rating
depth from original grade
5
GPD/SF
JTotal
Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
LAMPERT ESTATES 2 8
Fill added above original grade
Ft.
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
Ft'
Ft.
Well
200'+
--
200'+
25'+
TANK ® Septic ® S.T.E.P. ❑ Holding ❑ Other
Manufacturer
GREER
Capacity rper FLAGS
100 D + 1000 Gal.
Surface Water
100'+
--
100'+
Material
HDPE
Number of compartments
1 &2
Lot Line
10'+
--
10'+
NA
Foundation10'+
--
10'+
7
LIFT STATION
Manufacturer
ORENCO
Capacity
1000 Gai.
Remarks
Alarm location
GARAGE
Electrical installed by
PL&C
Tank to
PIPE MATERIAL House to tank 3034 3034
Installer NORTHERN EXCAVATION
d a of eld
Drainfield 3034 CO/MT 3034
Inspector FWCS
BENCH MARK (Assumed elevation) 100 ft
Inspdection 151 11/23/2020 11/23/2020
Location and description
2�d
Td 11/24/20 4'"
BOTTOM OF SIDING
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
%0��1`.�\\
A.
Conditional Approval: Date
'•:tQ,���
*: 49TM ....�:*fir
i. �-. .
'. "" """':'
• Curtis Huffman
�� ��`''' CE 128991• •�
�SlF�•.23/2021 •��v�i
Septic System
Approved -
Date o7�.Cl
(� F�PROFESSIQA
11
Note: this approval does not include well permit requirements.
(Ftev ub/u2/16)
PID: 051-791-09 PERMIT. OSP201353
A—C=22.6'
B—C=12.7'
A—D=22.0'
B—D=16.7'
A—E=23,9'
B—E=21,6'
A—F=25.2'
B—F=25.4'
CO MH
.98� DCO r0 100.02 'FINAL GRADE
94.96
1000 -GAL
1-COMPART.
HDPE TANK
LAMPERT ESTATES B2, L8
PREPARED FOR:
LUIS & FELECIA BAPTISTA
22545 LAMPERT CIRCLE
CHUGIAK, AK 99567
94.63
EXISTING FIELD
1000 -GAL
HDPE STEP
SEPTIC SECTION
SCALE, NTS
SUPPORT SERVICES:
e e
FIRST WATER CONSULTING
13030 Sues Way DATE: 02/03/2021
Anchorage, Alaska 99516 SURVEY: 2021
9 DRAWN: FWCS
(907)350-9566 SCALE: 1" = 30'
firstwaterAK®gmail.com
of A,���
* 9TH
rtis Huffman
ren CE 128991 ,��
2/3/2021 e�
nSSI0105' AV
S89�5815011
E
10' UTILITY ESMT
e SEPTIC
VENT
(typ)
tu.v
44.5'
N H
EXISTING 0
M
") HOUSE00
MH
ss�
44.5' r
CONC
0
28.0'
W,
L0
O
O
z
PAVED
D/W
DECK
LAMPERT CIRCLE
ANCHORAGE RECORDING DISTRICT, ALASKA
AS -BUILT OF:
LAMPERT EST'A'TES
LOT S BLOCK 2 PLAT 72-207
SURVEY CER'T'IFICATE: I, John L. Schuller, Have conducted a
physical survey of this property as shown on this drawing and that the
improvements situated hereon are within the property lines and no
enchroachments exist other than noted. Under no circtunstance should
any information on this drawing be used for construction of fences,
structures, improvements, or for establishing boundary lines.
EXCLUSION NOTES: It is the owners responsibility to determine
the existence of any easements; covenants, or restrictions which
do not appear on the recorded subdivision plat.
WORK ORDER NUMBER: DA SCALE: E-MA!U
JAN 7, 2021 1"=30'
21-006 DRANK BY: CHECKED BY GR!D NUMBER: BOOK/PAM'
JLS NW1459 210006
206.00'
UCPP,
0
OO = FIND 5/8" REBAR
�,�..oF ALS
�i
49Tx
.JOHN L. SCHULLER. o
N LS -10408 ®'
��•rm°fessio o o
LOT 9
BLK 2
C� y0 �D L NDS���
VM
1831 Talkeetna Street
Anchorage, Alaska 99508
(907) 227-1455 office
(907) 274-4992 fax
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP201353
Work Type: SepticTank Upgrade
Tax Code Number: 05179109000
Site Legal Address: LAMPERT ESTATES BLK 2 LT 8 G:1459
Site Mailing Address: 22545 LAMPERT CIR, Chugiak
Owner: BAPTISTA LUIS B & FELECIA M
Design Engineer: FIRST WATER CONSULTING
This permit is for the construction of:
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy
Effective Date:
Expiration Date:
Lot Size in Sq Ft
Total Bedrooms:
01R"
S
�
'
I■ l
Delilt •trnent
9/8/2020
9/8/2021
21656
❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By:
Issued By:
Date:
Date:
5
A 7 OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 051-791-09
Property owner(s) LUIS & FELECIA BAPTISTA . Day phone 4802520682
Mailing address 22545_E LAMPERT CIRCLE, CHUGIAK, AK 99567
Site address 22545 E LAMPERT CIRCLE, CHUGIAK, AK 99567
Legal description (Sub'd., Block & Lot) LAMPERT ESTATES B2, L8
Legal description (Township, Range & Section)
Lot Size 21,656 Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(N all that apply)
Absorption Field
❑
Initial ❑
Single Family (SF) El
(w/wo ADU)
Septic Tank
0
Upgrade El
Duplex ❑
(D)
Holding Tank
ElRenewal
ElMultiple
Dwellings ❑
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: 101 0 ►d-1�) Waiver Fees:
Date of Payment: a ,;� 11,520-?- C2 Date of Payment
Receipt Number: c�D� �2 3
Permit No. O2a01 353
Receipt Number:
Waiver No.
G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc
FIRST WATER CONSULTING
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
August 29, 2020
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC TANK UPGRADE PERMIT
LEGAL: LAMPERT ESTATES BLOCK 2, LOT 8
PHYSICAL: 22545 LAMPERT CIRCLE, CHUGIAK, AK 99567
The owner has requested we obtain a permit to upgrade the aged steep tanks of the referenced lot.
We propose to install two 1000-gallon HDPE tanks per the attached design to serve the existing
5-bedroom residence. The lot and surrounding properties are served by Class A well or public
water. The design will not impact any of the neighboring properties. Please contact us if you
have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201353, Deb Wockenfuss, 09/08/20
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP201353, Deb Wockenfuss, 09/08/20
Municipality of Anchorage
On-Site Water and Wastewater Program • (907) 343-7904 Page 1 of 1
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP131180 PID Number: 051-791-09-000
Dwelling:
1
Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New
0
Upgrade
Name:
Carl & Mildred Mclntrye
ABSORPTION FIELD
❑ Deep Trench ►/
❑ Other
Shallow Trench ❑ Bed
■
Mound
Address
22545 Lampert Circle, Chugiak, AK 99567
Phone
Number of Bedrooms
5
Soil Rating
0.6 GPD/SF
Total depth from original grade
5.5 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
2 Ft.
Gravel depth beneath pipe
3.5 Ft.
Subdivision Block Lot
Lampert Estates 2 8
Fill added above original grade
0.5 Ft.
Gravel length
137 Ft.
Township Range Section
Gravel width
5 Ft.
Beds: Number o Lines
1
Distance between lines
Ft.
SEPARATION DISTANCES
To
From
Septic
Tank
Absorption
Field
Lift Station
Holding
Tank
Sewer
Line
Total absorption area
1295 Ft2
Number of trenches
1
Dist. between trenches
Ft.
Well
1001+
100'+
1001+
__
251+
TANK Septic • S.T.E.P. ■ Holding ■ Other
Manufacturer
existing
Capacity
1000 Gal.
Surface Water
100'+
100'+
100'+
--
NA
Material
Steel
Number of compartments
2
Lot Line
5'+
10'+
5'+
--
LIFT STATION
Foundation
5'+
10'+
5'+
Manufacturer
Orenco
Capacity
500 Gal.
Curtain Drain
NA
NA
NA
--
Remarks
Pump on level at
44 in.
Pump off level at
42 in.
High water alarm at
48 in.
Pump make and model
Ofewj PFO
Electrical Inspections performed by
Cal's Electric
Installer Walker Construction
PIPE MATERIAL House to tank Tank to D3034
drainfield
Drainfield D3034 CO/MT D3034
BENCH MARK (Assumed elevation) 100 ft
Inspector ARCTERRA
Location and description
Top of ramp to permanent shed
Inspeection ction 15` 7/15/13 2nd 7/17/13
3" 7/19/13 4th 7/26/13
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Conditional Approval: Date
i���
/
/ i
= �`�`
OF ALS
TH
1 1
�,
pr�
P KENNETH . DUE opi2
116
�k,.-
Approved vi Dateg—S' )3\`�Ilir
Inspection Repo
AS -BUILT SYSTEM DETAILS/SITE PLAN Permit: OSP131180
LAMPERT BLOCK 2, LOT 8 PID#: 051-791-09
(79-245)
100.00
N
9. 58' 50'W
206,43 4 :16
10' UTIL ESMT
sa
MT
37'
L9C Tj'}fi33
5'
44,5' o
NEXISTING
HOUSE
28,
PRI "RY
TR In
Ex. Tank
0
.5
IF
= ff288..0' '4.
frp
7e 61.25'
0
t
500 gal. Lift Sta.
'4
9
SCALE! 1' = 40'
N
N
Z2,A—E=31.1
9B—E=27.2
°B—F=105.0
3C—F=119,4
sA—G=59.0
D—G=36.6
E
3
Ex, S.T
98,90)
500 gal.
LIR S ation
9TH TN
al A -vat ,A
ur
a I KENNETH M. D j S: /
CE -7116
777/«%.134.0�
FESSIO0j
1)
E
W
144
=
F
C101.06)
ORIGINAL GRADE
FILTER rANRcN
1wAatlan
SEWER ROCK
137'
<86.0 )
PREPARED FOR:
CARL & MILDRED MCINTYRE
22545 LAMPERT CIRCLE
CHUGIAK, AK 99567
FIELD BOOKS
BOUNDARY: NA
STAKING: NA
ASBUILE NA
OW. EEE:
COMPUTED:
DRAB' kmd
°HOi KMD
Dae 07/27/13
GRID' NW1459
ACRD TEE: 13-282
"11°' 13282
CSF C`0 C
•/P; LILTING.dry
yl
/PEA;
AK 99577'
Cal's Electric
PO Box 770236 Eagle River, Alaska 99577-770236
(907) 440-7948
Date: 7/17/13
Subject : 225545 Lampert Circle
Block 2- Lot 8
Peters Creek, Alaska
Cal's Electric installed conduit, wire and connections to lift station motor and
panels at above address. Per NEC and State Codes.
Calvin Evans
t;�
00 //S. '3
On -Site Wastewater Disposal System Permit
Permit Number: OSP131180
Tax Code Number: 05179109000
Work Type: Septic
Permit Effective Dates: July 11, 2013
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
to July 11, 2014
Design Engineer: ARC TERRA CONSULTING INC
Subdivision: LAMPERT ESTATES
Site Legal Address: LAMPERT ESTATES BLK 2 LT 8 G:1459
Owner/Address:
MCINTYRE CARL D & MILDRED A
22545 LAMPERT CIRCLE CHUGIAKAK 995675432
Site Mailing Address: 22545 LAMPERT CIR, Chugiak
Lot Size in Sq Ft: 21656
Total Bedrooms: 5
oc
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Date: 7—N— /3
Date:
MUNICIPALITY OF ANCHORAGE
Community Development Department
Development Services Division
On -Site Water & Wastewater Program
Phone: 907-343-7904
Fax: 907-343-7997
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-791-09
Property owner(s) CARL & MILDRED McINTYRE Day phone
Mailing address
22545 LAMPERT CIRCLE, CHUGIAK, AK 99567
Site address 22545 LAMPERT CIRCLE, CHUGIAK, AK 99567
Legal description (Sub'd., Block & Lot) LAMPERT BLOCK 2, LOT 8
Legal description (Township, Range & Section) £S
Lot Size 21656 Sq. Ft. Number of Bedrooms 5
APPLICATION IS FOR:
(El all that apply)
Absorption Field []
Septic Tank
Holding Tank ❑
Privy ❑
Private Well ❑
Water Storage ❑
APPLICATION IS AN:
Initial
Upgrade
Renewal
TYPE OF DWELLING:
Single Family (SF)
(w/wo ADU)
Duplex (D)
Multiple Dwellings
(SF and/or D)
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
C/bttk
r}�tur f property owner or authorized agent)
Permit/Rush Fees: 530 —
Date of Payment: 71?j! 3 C
Receipt Number: 015 1-\\\
Permit No. 05%Q1'311
Permit App_9-1-12.doc
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
June 28, 2013
ARCT ERRA
CONSULTING, INC
212 E. 51s` Ave, Anchorage, AK. 99503
Office (907) 868-3791, Fax (907) 868-3793
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Upgrade Sewer Permit — Lampert Estates Block 2, Lot 8
It has been determined that the undocumented absorption field of the subject
property is in failure and may be encroaching groundwater. Subsequently, the
owner has requested we proceed forward to obtain a septic permit to upgrade
the septic system.
The general slope of this lot is from north to south at a grade of approximately 0-
5%. On June 21, 2013 testholes was performed to investigate soils and
groundwater. The results of these tests are attached for your review. The
proposed upgrade will serve the existing 5 -bedroom house. We propose to install
5' -Wide pressurized trenches. Groundwater was encountered at 10.5' at
monitoring.
The property and adjacent lots are served by community water. There are no
known curtain drains within 50'. We do not expect there to be any adverse effect
on adjacent lots by the development of this system. If you have any questions,
please contact me at 868-3792 / FAX 868-3793.
Respectfully submitted,
ArcTerra Consulting, Inc.
Kenneth M. Duffus, P
Attachments: On -Site Sewer Application
Wastewater Absorption System Details / Site Plan
Soils Log/Percolation Test
20441 PTARMIGAN BLVD • EAGLE RIVER, AK 99577-8736 • PH (907) 868-3791 • FAX (907) 868-3793
i
0
Iu
a
WASTEWATER DIS P LSAL SYSTEM DETAILS
LAMPERT BL❑CK 2, LOT 8
3' 0"W 2
' UTIL ESMT
INS
NEW 500
GAL STEP
PRESSURIZED DISTRIBUTI❑N SYSTEM HOLE SPACING DESIGN
1. RESIDUAL HEAD = 5'
2. HOLE SIZE = 3/16' = 1.00 GAL. PER HOLE @ 30 PSI
3. 30 GALS (PUMP DELIVERY)/1.00 GALS./HOLE = 30 HOLES
4. 136 LF LATERAL/30 HOLES = 4.5' SPACING PER HOLE
5. ALL HOLES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS.
40, • TH%\
CE -7116 fir
W
) oFE331OT1A
re✓isron,5 7-1/-/3 de,a_
,0�
Scale: 1"= '['
PAGE 2 OF 2
PREPARED FOR:
CARL & MILDRED MCINTYRE
22545 LAMPERT CIRCLE
CHUGIAK, AK 99567
FIELD BOOKS
BOUNDAfY: BOUNDARY
STAKING
REJ
STAKING`
ASBUILT:
DWG. RL
ACRD FlEE FILE
COMPUTED:
DRAWN: BMW
CHECKED: KMD
DATE: 6/28/13
GRIM N W1459
JOB N°° 13-141
oti WCTER*9
a
a M
-2
��"`Y\ 41 ^tee
�4/4'SULTING ,`�°
A% AK. 99571 -1
WASTEWATER DISPOSAL g YSTEM DETAILS/SITE PLAN
LAMPERT€BL❑CK 2, LOT 8
S89.59'29'yp 1319.779 <Meas)
00 y_v
I ou.00 97Af
146.85 \ 174.21 <82
FLAG PROPERTY LINES
& EASEMENTS
PRI❑R TO CONSTRUCTION
DESIGN DETAILS
NO PUBLIC WELLS WITHIN 200' OF
PROPOSED SYSTEM.
NO PRIVATE WELLS WITHIN 200' OF
PROPOSED SYSTEM EXCEPT AS NOTED.
NO SEPTIC SYSTEMS WITHIN 200' OF
PROPOSED WELL EXCEPT AS NOTED.
re✓iSiens 7- ll -13 deg
'\Server\storage\WE
SUBDIVISI❑N SERVED
BY PUBLIC WATER
Scale: 1"= 100'
PAGE 1 OF 2
5 BDRM X 150 GPD = 750 GPD
750 GPD/.60 GPD PER SQ. FT. (18 MIN/IN.)= 1250 SQ. FT
(125 /5'W) x .54 (RF 3.5'ED)) = 135' L
USE 'WRENCHES 8 t(L) X 5' (W) X 3.5' (ED)
Total depth of' system Is 5.5' max from original grade.
Total depth of gravel below distribution pipe is 3.5' .
NOTES!
1. INSTALL 500 GAL STEP & INSULATE TANK IF <4' COVER.
2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM IF < 3' OF FILL.
MIN. 2' FILL WITH INSULATION, >3' COVER NO INSUL REQ.
3. CONTRACTOR WILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK.
4 CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT
WELLS, SEPTICS EASEMENTS, PROPERTY LINES, ETC... L
G`&x/rczee.Me larr4� :reJ��2y io» dt5fiucu, from c<la�re/,4 r bo-�-
2urc;
fn/ f/en. (/at '7-11-1
X70
PREPARED fOR:
CARL & MILDRED MCINTYRE
22545 LAMPERT CIRCLE
CHUGIAK, AK 99567
FIELD BOOKS COMPUTED:
BOUNDARY. BOUNDARY DRANN. BMW
STAKING: STAKING cHEaOO): KMD
ASBUUU.T: REJ
DATE:
6/28/13
DWG. FILE:
ACAD FILE' FILE
DRID: NW1459
°B N°` 13-141
i i,zrvaarn�1
3: t
�e' :A���,01
cC.'.0°021),
0 04'8111 TI NG , \.yg Lam^
A' AK. 99577,E
tisRCTERRq
ARC T ERRA
CONSULTING, INC
212 E. 51st Ave, Anchorage, AK. 99503
Office (907) 868-3791, Fax (907) 868-3793
SOILS PERCOLATION TEST
e
;VS
s * e •4 Ta •
•••:• ••..i• • 4
•••
1111,Kenneth M. Co
IK V% CE 116
• lF •• .tom
Performed for: Carl & Mildred McIntyre Date Performed: 06/21/2013
Project:
Depth
(Feet)
15-
16-
17-
18-
19-
Lampert Estates Block 2. Lot 8
ORG/OL
SM/GM
B.O.H.
HOLE PRESOAKED
20- PRIOR TO TESTING
TEST HOLE # TH 13-1
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? NO
Depth to water after monitoring? 10.5'
What depth? NA
Date? 6/28/2013
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
6/22/13
1:00
6"
-
2
1:30
30 min
4 0/16"
2 0/16"
3
*
1:31
-
6"
-
4
2:01
30 min
3 15/16"
2 1/16"
5
*
2:02
6"
-
6
2:32
30 min
40/16"
20/16"
7
8
9
10
11
12
Water
Added
Percolation Rate 15 (min/in) Perc Hole Diameter
Test Run Between 4 feet and
5 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State
and Municipal guidelines in effect on this date.
poRCTERRq
ARC TERRA
CONSULTING, INC
;' 212 E. 51St Ave, Anchorage, AK. 99503
Office (907) 868-3791, Fax (907) 868-3793
SOILS PERCOLATION TEST
Performed for: Carl & Mildred McIntyre Date Performed: 07/17/2013
Project:
2-
3-
4-
5-
6 -
Depth
(Feet)
Lampert Estates Block 2. Lot 8
ORG/OL
SM/GM
B.O.H. - PERC BENCH
7- CONFIRM EXISTING
CONDITIONS
8-
9-
10-
12-
13-
14-
15-
16-
17-
18-
19 -
HOLE PRESOAKED
20- PRIOR TO TESTING
TEST HOLE # TH 13-3
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? NO
Depth to water after monitoring? NO
What depth? NA
Date? 7/17/2013
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
7/17/13
11:00
-
6"
-
2
11:30
30 min
4 3/16"
1 13/16"
3
*
12:31
-
6"
-
4
1:01
30 min
4 5/16"
1 11/16"
5
*
1:02
-
6"
-
6
1:32
30 min
4 5/16"
1 11/16"
7
8
9
10
I1
12
*
Water
Added
Percolation Rate 18 (min/in) Pere Hole Diameter
Test Run Between 4 feet and
5 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State
and Municipal guidelines in effect on this date.
04 c cTERRq
ARC 1 m
ERRA
a
Ahes,iti995'
1 CONSULTING, INC
212 E. 51st Ave, Anchorage, AK. 99503
I Office (907) 868-3791, Fax (907) 868-3793
SOILS PERCOLATION TEST
Performed for: Carl & Mildred McIntyre Date Performed:
Project:
Depth
(Feet)
2-
3-
4-
5-
6-
7-
8-
9-
10-
12-
13-
14-
15-
16-
17-
18-
19 -
Lampert Estates Block 2. Lot 8
ORG/OL
SM/GM
B.O.H. — PERC BENCH
HOLE PRESOAKED
20- PRIOR TO TESTING
TEST HOLE # Til 13-2
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? NO
Depth to water after monitoring? NO
What depth? NA
Date? 6/28/2013
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
6/22/13
1:00
-
6"
-
2
1:30
30 min
4 3/16"
1 13/16"
3
*
1:31
-
6"
-
4
2:01
30 min
45/16"
1 11/16"
5
*
2:02
-
6"
-
6
2:32
30 min
45/16"
111/16"
7
8
9
10
11
12
*
Water
Added
Percolation Rate 18 (min/in) Pere Hole Diameter
Test Run Between
4 feet and 5 feet
I, Kenneth M. Duffus, certify that this test was performed in accordance with all State
and Municipal guidelines in effect on this date.
Performed For:
Legal Description
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
+.aaw.ci anc_m_age. ai:. us
. (907) 343-7904
Soils Log - Percolation Test
VI ifirit; effAi2iCted
'NG
41.44P4‘ °R.FS7 i!.), e �lr ��,
;,t; 49113 f% ®/
_ 90/
MICHAEL E. ANDERSON :44? a
#1VyyCsE -4�1 4:te1111. .e..+9
1<,`�
Date Performed: 7,` q 'Lr9'[ O
Township, Range, Section:
6-
7-
8
9-
10-
11-
12-
13-
14-
15-
16-
17 64
18-
19
Slope
WAS GROUND WATER
ENCOUNTERED?
P 5
IF YES. AT WHAT DEPTH? — (L`,
Depth to Water After 0
Monitoring? / la
E
Date: __ 142ll
Site Plan
Reading
Date
Gross Time
Net Time
to ga er
DeptheJr Nff
Ntl,t Dr .
I
6 7/
i', *\ia '
154.11642`i
(c) MIA(5
t.ip3%9.3$ r
1215 d
3,q-
1
ten,n,-,kli
® (1
G.51/5.ty'
2,69`
,/.101
G(d i /(ro'2ti
Ir
tsi,,/),1,5
2x6,,,,i
„,,i,t
ye -4, 3. 32
,a a
f,5?
5, 1,
444!11
PERCOLATION RATE
TEST RUN BETWEEN
COMMENTS 11 3 %y n'I7 \?"A1 ,. ht 2
(minutesMch)
FT AND
PERC HOLE DIAMETER
4, FT
PERFORMED BY:e,74'¢ I - - CERTIFY THAT THIS TEST WAS
PERFORMED IN AC ORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Performed For:
Legal Description:
6-
7-
8
9-
10-
11- .�
12-
13-
14
15-
16-
7-
18
19-
20
COMMENTS
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
w.c
__ i. ehoraue. Suss
s:r (907) 343-7904
Soils Log - Percolation Test
lig YI4n4t r/? Ef116 WA; l, -y
Srrope
40
e trnatS ,4 %
r00oaa••1Jl r• *)) s491E e% *,0
0 I°•4. ANDERSON : 4
lifi
S. CE -4381 :��'�
#�1r�9f. ,T43-() .•i4i
f11 4j1 n% �'`
Date Perfo med: -1 It ! 401112
Township, Range, Section:
WAS GROUND WATER
ENCOUNTERED?
a
IF YES, AT WHAT DEPTH? , L
0
Depth to Water After r
Monitoring? / E
Date:
Site Plan
Reading
Date
Gross'Time
Net Time
Depth to Water
Net Drop 11
eilfqlo
Ito;Z
....^
57."
—
L
IL;5-S
.-6Ftub
[[,a"
.34t"
3
If,:�7S•;5v
—
1.5"
—
4
iiiv3t3®
30 ti vis
il,o"
'7.7-t`
/
y
rpo
1.4f"
-----
L.
V
11'35
"2-e,t11 s
4f,q"
3,s- "
TEST RUN BETWEEN
57)414-52.9Co t!T/
(minuteMnch)
FT AND
2
5A -FTHOLE DIAMETER
S/2FT
8r1
PERFORMED BY: .r 4 1 CERTIFY THAT THIS TEST WAS
PERFORMED IN AC6ORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Performed For:
Legal Description
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
anithoraue.0 Luz
(907) 343-7904
Soils Log - Percolation Test
Date Performed:
.111 AR_P96v 1~471 jownship, Range, Section:
3104
8-
9-
10-
11-
12-
13-
14-
15-
16-
17 -
COMMENTS ftetT,S0
WAS GROUND WATER
ENCOUNTERED?
s
IF YES, AT WHAT DEPTH? 't4 X)( LL
Depth to Water After t /
Monitoring? (°t6 ' t$
Date:
!A
Site Plan
Reading
Date
Gross Time
Net Time
Depth to Water
Net Drop
1
iI Vft
f g;51
5:(e3°
Z
I
11 2I
3o ti HO
9rW
3. =
3
4--
1
(i fl
3D elk
9,i i
3.9/
C
(
. lb:0 i
P"
9.'‘
b
v
Int
iia t11WWs
5.1Z
.54c36
PERCOLATION RATE
TEST RUN BETWEEN
-17 'Ixk/l t )�
(minutes/inch)
FT AND
PERC HOLE DIAMETER
FT
PERFORMED BY:
CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDAN E WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Municipality of Anchorage Page I of a
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 0 Telephone: 343-4744
On-Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SL`-'414 °N59 PID Number' 051 791 09
Name:
71vv‘
OSIN
Wastewater System: 0 New ;Upgrade
Address:
p o,$ox oi-00 cHuoIAK fl K. CHHs()-7
ABSORPTION
Phone:/ g g _ 'IQ/
b
No. of Bedrooms:
rj
>3Deep Trench 0 Shallow Trench 0 Bed 0 Mound ❑Other
LEGAL DESCRIPTION
'Soil Rating:
(7 • 0 GPD/Sq. Ft.
Total Depth from original grade:
10'
Gravel depth beneath pipe
Co 1 Ft.
Lot: C2 Black: Subdivision:
C'7 t-.041,4?-6-727- QST,
Depth to pipe bottom from original grade:
it Ft.
Township:
Range:
—
Section:
Fill added above original grade:
Gravel length:
1O-] Ft.
O,STc9 I.S1 Ft.
WELL: c4l New 0 Upgrade
' EX I ST rN
Gravel/width: a
Ft.
Number of lines :
I
Distance between lines:
Ft.
Classification (Private, A,B,C):
e0"04•/ti/TY
Total Depth:
Ft.
ed To:
Ft.
Total absorption area:
1Dey SQ. Ft.
Pipe material: AST v.n
F.61°7'3039
Driller:
ate Drilled:
Static Water Level:
Ft.
Installer:
CUAL.KER CONST
Date installed:
%-7-qs
Yield:
GPM
Pump Set at:
Ft.
Casing Height Above Ground:
Ft.
TANK
SEPARATION DISTANCES
Septic ❑ Holding
❑ S.T.E.P.
To
From
Septic
Tank
Absorption
Field
Litt
Station
Holding
Tank
Public/Private
Sewer Lines
Man facturer:
1VCfl0R.462 //1NK
Capacity in gallons:
16-00
Well-
spot
aOelfi
•-r
—�
a5+
Material:
�TserL
Number of Compartments: a
SurfaceLIFT
Water
(001-1-
l 00 a-
—
--
STATION
%
/
Lot
Line
a- 3 �
1 . I
__
Size in gallons:
Manufacturer:
Foundation
l01
l01
��
._
"Pump on" level at:
"Pu • • " level
at:
High water alarm at:
Curtain
Pump Make : • ••eI
Electrical Inspections
performed by:
Drain
/ONE
K/�/D
t,JN
Remarks:
BENCH
MARK
Location and Description:
-F;P Or`-
dONCRE7W S48
n
(� 4-20NP" or /7OL.)so-
Assumed Elevation:
47.g Ft
EN
... L
q
tc:; s7�
S & 5 ENGINEERING
17034 Eagle River Loop Road, No. 204
Inspections b Dates: 1st -6-9S
,IS
° h9. ' I
r
performed
2nd 77(
.3;1\ ROBERT C, COWAN
Department of Health and Human Services approval
Reviewed and approved by:,�� !' Date. 8 -4 '" 9s
1
VIZ"'
�s:� CE-8801 �*
I.s.., F�'o,e; ioN°\��� e
�� cu
72-013 (Rev. 9/91) MOA 25
SW940439
Permit No.
2 2
Page of
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
LOT 8, BLOCK 2, LAMPERT ESTATES 05179109
Legal Description: PID No.:
ST1 ST2
EXIST. UNDOCUMENTED SEPTIC SYSTEM -
ABANDONED COMPLETELY
V,1,1 • NO WATER FOUND
10' UTIL ESMT
NEW 1500 GAL
SEPTIC TANK
LOT 8
04
T2
EXIST
5
5 BDRM
HOUSE
-NEW TRENCH
FCO
ST1
ST2
001
02
CO3
C04
MT1
MT2
A
23'
25'
31'
32'
40'
59'
GO'
B
25'
28'
30'
32'
31'
27'
81'
28'
82'
fl
33'
34'
vi:\ ROBERT C. COWAN
c41 • CE -8801
aA.%N• 4* • „C'..
T•(.1
'...,.o,.... .1\
•Ivik
thIC talgitala°
72.013 A (1/93) •
2,?/ 07
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE k 2 N,
DEPARTMENT OF HEALTH AND HUMAN SERVICES-!�-�
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, ALASKA 99519-6650
ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT
PERMIT NUMBER:SW940439
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:ROSIN JAMES S & TAMMY J
OWNER ADDRESS:P.O. BOX 0490
CHUGIAK, AK 99567
PARCEL ID:05179109
LEGAL DESCRIPTION: LAMPERT ESTATES BLK 2 LT 8
LOT SIZE: 21656 (SQ. FT.)
NUMBER OF BEDROOMS: 5 THIS PERMIT: 5
THIS PERMIT IS FOR THE CONTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH:
DATE ISSUED:11/29/94
EXPIRATION DATE:11/29/95
1. THE ATTACHED APPROVED DESIGN.
2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS
15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80).
3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 (24 HOURS) .
4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED AND CLOSED ON THE SAME DAY
B. COVERED, SEALED AND HEATED TO PREVENT FREEZING
5. THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS:
/(RECEIVED BY:
ISSUED BY:
DATE:
/7
DATE: //-C-c'}-
S&S
ngineeiinq
EAGLE
RVER,
A VSI(A
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER& WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL&
MECHANICAL
INSPECTIONS
ON SITE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
ROBERT C. COWAN, P.E.
ROBERTA. SHAFER, P.E.
November 17, 1994
Municipality of Anchorage
DEPARTMENT OF HEALTH AND HUMAN SERVICES
825 "I_" Street
P.O. Box 196650
Anchorage, Alaska 99519-6650
REFERENCE: Lampert Estates Subdivision, Block 2; Lot 8
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
Request you issue a permit to replace the septic system serving the five
bedroom house on the referenced property.
A test hole was excavated and a percolation test performed in the area of the
proposed upgrade. The approximate location of the test hole is located on the
attached site plan. The monitoring tube within the hole has been checked and
is found to be dry. Attached is the proposed upgrade design. This property is
served by a Community Water System.
We do not anticipate any adverse effects on neighboring properties by the
installation of the proposed septic system. There are no protective well radii
which encroach upon the property.
If you have any questions, or require additional information for your review,
please contact us.
Sincerely,
Robert C. Cowan, P.E.
RCC/JA/sm
17034 NORTH EAGLE RIVER LOOP • SUITE 204 • EAGLE RIVER, ALASKA 99577
Set,Nt
•
s3J
00 j a,
' !i
}
w y�.''r
wUc 23
c.JJ��
0
z
o 0
CCW~
=
a
L.1
W
err
cet Q
Op
VSO
/- Z Y
/-
o�
Z H -
O
ooa�
SEP
W
F -
vi
W
J
0
2
1-
(/1�
w
11 • F -w0
Z 1- 7
IJ
w a l-0
1- o p_ (U, J
z Q w w.
H O o Z P.0 d
41
Z Z U- o 0 O
wz
al-- a ,. NW'cO.-
=o ,ct,r
Q0 z0-0
o w CC
aV) UV)d
0 a
Z r0 Wo V)
W W m Z 1-W W
W CC Z
CC a Z%' w 5 J
CO o<> ow>-
F- G. o D i- w
J
1- W W2- m F.. 0
04 Z CC
W V1 >S ZW a.
Q= V)-. Ow0 z
(N I- I- wwap
V) JCC
F w
WZ-a
Ct o coot W L...W= Ecn
-,
i� i_z 1�FcZCC
O V7 n5aa (nj
0
J
N
U
0
m
(1)
J
1—
Q
(n
J
vi
0
d
U
or
m
2
ND021
aRe1as
0
1
da3Q • --
1nLLOMIDIN `J--
•.
00001 •0.00.
1410024P.:..!dd.
O
CROSS-S;HCTIO\
N01103S-X
31V3S
'STN
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: �D(M P 0`51 n7
`^y ROBERT C. COWAN �;'F
CE -8801 •�'Fi
•
DATE PERFORM (to }-rS
tl
LEGAL DESCRIPTION: 1.--c"T" 1,4prrTownship, Range, Section:
1
2
3
4
5-/0•Ifi'vl/ft) ty
8
9
10
11
12
13
14
15
16
17
18
19
20
oe-
C3,00-\
(.r- SLOPE
WAS GROUND WATER
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
Depth to Water Atter
Monitoring? t7
Date \k- \\-61
S
L
0
P
E
SITE PLAN
N
17
Reading
Date
Gross
Time
Net
Time
Depth 4.
Water
Net
Drop
PERCOLATION RATE ..21�
(minutesnnch)PERC HOLE DIAMETER
TEST RUN BETWEEN __ FT AND FT
COM TS 7k � d- i F -e --c1 (J RE.
i�e V /'J i),7
PERFORMED BY'
CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
72-008 (Rev. 4/85)
Performed For:
Legal Description:
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
- (907) 343-7904
Soils Log - Percolation Test
�fufrl-+{A6va
SVI ,r i ' WIG c-lit`!�
5-
6-
7-
8-
9-
10-
11-
12
13-
14-
15
16-
17-
18-
19-
20 -
Slope
WAS GROUND WATER
ENCOUNTERED?
`••`OF �1tN
th
• w./
fiS • •
ra EL MICHAE. ANDERSON : Q
r
I , . CE - 4381 .7_4? at
la PPP ESSIOON. lb*
Date Perfo med: 'flq 4T.Iter
Township, Range, Section:
5
IF YES, AT WHAT DEPTH? -- Ito P
Depth to Water After O
Monitoring?
Date 12710
Site Plan
Reading
Date
Gross Time
Net Time
Depth to Wa4ter
�elr.
Net r r
4,7i
11 \utp
I5'd915,21
(e7 MMin(s
join;7,..38"
2,15
S
1 e/t i 4:g
II
0.449. IV°
62,81"
7, b'
(5,119/tC )
c/Ia
I
ILI07((d2y
It
1,51,i 'Al
24e,i
Inv
1
:J
I to:2'7/3®132!
.a +1.
1,-5.
9.1,
24'U
minutes/inch)
},,
TEST RUN BETWEEN 5, r; FT AND
COMMENTS tre-0504& 7,. it'Oty:
PERC HOLE DIAMETER
to FT
PERFORMED BY:d ¢-I 1 - CERTIFY THAT THIS TEST WAS
PERFORMED IN AC ORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Performed For:
Legal Description
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
va_nchoraee.ai:.us
(907) 343-7904
Soils Log - Percolation Test
rkgfitilid lkittiotcri
'u &ILiAt-f rick Kiv( l:•v L
Scope
8-
9-
10-
11-
12-
13-
14
15-
16-
17-
18
19-
20 -
COMMENTS
WAS GROUND WATER
ENCOUNTERED?
�° MK]lAfi. E. ANDERSON R
* 70%�� CE - 4381 ; to
# ^..:s. 5-bsi_J ,..t'
Date Petmed: 7� it ?.c!•10
111iii
Township, Range, Section:
J� S
IF YES, AT WHAT DEPTH? -1l-G� L
Depth to Water After
s I ! P
Monitoring? E
Date:
510
Site Plan
Reading
t
Date
Gross"Time
I(fl
11,;c8
Net Time
'J© Ktli
Depth to Water
It a "
Net Drop 11
3
e
I(, �;5a
4-
1-1103,3(0
30 pits
1.9“
•349-"
rl.o"
'7is
y
I7;o
L
11'3)
'7o MU(S
ITT'
.cin
3,y6,.
PERCOLATION RATE (minutes(nch)
TEST RUN BETWEEN FT AND
3S1)C(22 Co
1a PERC HOLE DIAMETER
6-4FT
ail
PERFORMED BY:
r 1 CERTIFY THAT THIS TEST WAS
PERFORMED IN ACgORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
Performed For:
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 Elmore Road
P.O. Box 196650 Anchorage, AK 99507
i.anchor oe.al:u _
°rY (907) 343-7904
Soils Log - Percolation Test
Md',,k'jrFJ I-V ea J
or fir; R' gEAfiksha
;fid
i * so • 49TH .,w*`��
sire
j••w••a igt
to • AMCHAEL-E. ANDERSON
4 OCE -4381 4.a
•• e•
7(IB /ZOW
Date Performed
Legal Description: _ Y lWAAab 9(1L- 1 ilownship, Range, Section:
Sloie
14-
15-
16-
17
18-
19-
20 -
COMMENTS
WAS GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT DEPTH? V. X C 01 -
Depth to Water After Ate,
Monitoring?
Date:
If0E
Site Plan
Reading
Date
Gross Time
Net Time
Depth to Water
Net Drop
'V/ lit 9
16191
i"
‘ 3'
f
V3
17;Z?
3o P114
9.66"
3,te
t1'Z5
5-5-6:1
r1rya,?voids
9,.12
'1•9e4
rJ
. ie3q D l
9.ci
b
II /
7�
10' i
�?''1 r 5
'net'
3iO3n
PERCOLATION RATE
TEST RUN BETWEEN
' Zl so -ii , Kr., t I�
(minutes/inch)
FT AND
PERC HOLE DIAMETER
FT
711
PERFORMED BY:
CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDAN E WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:
ON-SITE WASTEWA'fP:R DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
REFERENCE: Lampert Estates Subdivision; Block 2; Lot 8
GENERAL:
1. The scope of this project includes the installation of a 1500 gallon
septic tank and a leachfield trench to serve the proposed five bedroom
residence located on the referenced property. The current sewer pipe
from the house to the septic tank protrudes through the north foundation
wall above ground level. This section of pipe must be abandoned and a
new section rerouted to exit the east foundation wall a minimum of 2'
below existing ground level and insulated to protect from freezing, per
attached design.
2. Construction shall be in accordance with the approved site plan and
design drawings, Municipal permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater Disposal
Regulations.
3. The contractor shall be responsible for obtaining any necessary
underground utility locates.
4. Unless specifically agreed otherwise, the property owner shall be
responsible for final grading areas subsequently depressed from soil
settling. On all leachfield mound systems, the property owner shall be
responsible for ensuring a satisfactory vegetation growth over the
mounded area.
5. Contractors installing wastewater disposal systems must be certified by
the Municipal Health Department for system installations. Owners
installing their own systems must also receive prior approval from the
Municipal Health Department.
6. The existing undocumented leachfield is to be abandoned in place. The
existing undocumented septic tank is to be excavated, pumped, crushed,
and abandoned in place.
SEPTIC TANK INSTALLATION:
1. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
2. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
Page Two
Lampert Estates S/D, Block 2, Lot 8
November 17, 1994
3. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
4. Septic tanks installed with less than 4' of cover shall be insulated.
5. A foundation cleanout shall be installed one to four feet from the
building foundation. In the line between the tank and the leachfield
there shall be two adjacent cleanouts (unless an effluent pumping system
exists within the septic tank). These cleanouts shall be located on
undisturbed soil not more than 10' from the tank. The first cleanout,
in line, shall be to clean toward the leachfield. The second cleanout
shall be to clean toward the septic tank.
6. Final grading over the septic tank shall be such that a positive slope
exists away from the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
1. Excavate the proposed trench to the dimensions shown on the design. The
bottom of the excavation shall be within 2 inches of level. If the
sidewalls of the excavation become smeared, they must be raked or
scratched (roughed -up) before gravel (sewer rock) placement.
2. Once the gravel is installed, the distribution pipe is to be installed
level with the perforations faced downward. Gravel is then to be placed
over the distribution pipe to provide a minimum of 2 inches of cover
over the pipe.
3. A silt barrier must be installed between the final gravel layer and the
native soil backfill. Ensure the silt barrier covers the entire gravel
surface before placing backfill.
4. Monitor tubes shall be of four (4) inch diameter and installed
approximately in the locations shown on the design. The portion of the
monitoring tube extending through the gravel shall be perforated from
the bottom of the trench to the invert of the distribution pipe. This
is equivalent to the effective depth of the gravel as noted on the
design.
Page Three
Lampert Estates S/D, Block 2, Lot 8
November 17, 1994
5. Backfill over the final gravel .layer must not be less than twenty-four
(24) inches. Insulation must be installed when the backfill depth is
less than thirty-six (36) inches. The finish grade over the trench must
be mounded to prevent the formation of a depression after settling.
MINIMUM MATERIAL SPECIFICATIONS:
1. Any septic tank proposed for installation must be constructed by a
Municipally approved septic tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Type of Pipe Perforated Solid
Cast Iron
ASTM D3034 (PVC)
ASTM F810 (HDPE)
ASTM D2662 (ABS)
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Use of a type of pipe other than listed above must be approved by the
inspecting engineer.
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Company Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable nontoxic silt barrier (Typar 3401, Mirafi 140/N, or equal)
must be installed between the final leachfield gravel layer and the
native soil backfill.
6. All leachfield gravel (sewer rock) shall be 0.5"-2.5"
with less than 3% passing the #200 sieve.
7. When sand is being used as a filter material,
screened gravel
its gradation
specifications must conform to current M.O.A. or D.E.C. requirements.
Page Four
Lampert Estates S/D, Block 2, Lot 8
November 17, 1994
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the
installation of the wastewater disposal system. These inspections will occur as
follows:
1. The first inspection must be conducted after the excavation of ditches,
pits, trenches, or beds and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled before this
inspection.
2. The second inspection must be conducted after the placement of the silt
barrier, gravel, distribution lines, standpipes, cleanouts, and
insulation, but before the placement of any other backfill.
3. The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required, especially with the
installation of multiple trenches, sand filters, pressurized distribution
systems, etc. Thus, the inspecting engineer is to be contacted at least 24
hours prior to the start of construction. If necessary, a pre -construction
meeting will take place on-site. The inspecting engineer will not coordinate,
direct or control in any way the contractor's activities.
The owner shall contract with the contractor to perform the work outlined in
these specifications and plans and in accordance with the attached M.O.A.
permit. There will be no contractual arrangement existing between the
contractor and S & S Engineering. S & S Engineering shall be the owner's
representative and will inspect the work as stated above to document the
contractor's activities. Final acceptance of the contractor's work rests with
the owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or
omissions of the contractor or any other persons performing work on this project
or the failure of the contractor to carry out the work in accordance with these
construction documents. S & S Engineering's inspecting engineer will not be
responsible for the construction means, methods, techniques, sequence,
procedures or the safety precautions incident to this project.
CONTRACTOR/INSTALLER
orn
000)
ce) co
It
(Y) (Y)
C) C)
CD CY)
U X
cB
LL
> U)
00
A�I
O
N
00
d'
cu
0
C
O
co
Q
X
W
C)
CD
CD
TT1
G)
O
I
r
d7
I
LO
O
C)
a)
U
17�'
•
co TVJ
VJ
J Y
N Q
Y
J
Co
LLI U
Q
F --
U) U) F�-
W ll�
/'F�—/ W^
L1_ LLC
^W G
I L
Q
J
c N
O N
ZZ U)
U N
U
0 _0
ca
CM (2)
J U)
T`
LO
0
a)
O
0-
C -
CU n.(Q
a)
co
N
U)
a)
U)
a)
c
O
a)
X
N
CD
N
LO
co
ca
U
a)
U
(0
C
L
L
M.
0
o 0
c
0LL
0
L
ca
20
O
E
O
O
a)
c
CD
.a
.0
~
p
U
CL
Z��
E�
N
O
U
p
N
va)
N
t
~
i
_a
m
aci
m
0CO
N
.p
c6
o
O
N
d
O
0.
+'_+
c
Q
cn
4-
p
N
O
U
3
O
E
i
Q
=
,O
vi
.E
>c
OL
M
Q
0
-0
C
O
O
Q.
Q
p l
y®
Q
a)
N
L
N
E
cnN
0
v
p
=
ca
O
L
L
O
^,
U)
1
O
O>
+3
v
U)
p
AO
c'
a)
-0
Q
r
_^
Q
^,
+�
O
c
(n
L
®
O
Q.
O
to
0
t
�
c
a)
L
Q-
a)
U
•L
cB
LL
> U)
00
A�I
O
N
00
d'
cu
0
C
O
co
Q
X
W
C)
CD
CD
TT1
G)
O
I
r
d7
I
LO
O
C)
a)
U
17�'
•
co TVJ
VJ
J Y
N Q
Y
J
Co
LLI U
Q
F --
U) U) F�-
W ll�
/'F�—/ W^
L1_ LLC
^W G
I L
Q
J
c N
O N
ZZ U)
U N
U
0 _0
ca
CM (2)
J U)
T`
LO
0
a)
O
0-
C -
CU n.(Q
a)
co
N
U)
a)
U)
a)
c
O
a)
X
N
CD
N
LO
co
ca
U
a)
U
(0
C
L
L
M.
0
o 0
m Q
M
0
L
ca
20
O
E
O
O
a)
c
CD
.a
.0
~
p
U
CL
Z��
E�
N
O
U
p
N
va)
N
t
~
i
_a
m
aci
m
0CO
N
.p
c6
o
O
N
d
O
0.
+'_+
c
Q
cn
4-
p
N
O
U
3
O
E
i
Q
=
,O
vi
.E
>c
OL
M
Q
0
-0
C
O
O
Q.
Q
CL
E
Q
a)
N
L
N
E
cnN
0
v
p
=
ca
O
L
L
O
^,
U)
1
O
O>
+3
v
U)
p
AO
N
W
E
^
O
a)
-0
Q
r
_^
Q
^,
+�
O
c
(n
U
E
O
ow
O
to
a)
.►d
t
�
c
a)
L
Q-
t
c
X
0
in
U) - in
N >
U LL 'D
4) C: Q
O 0
U :_.
H Q " Q
Z 0 U) C
W O -0 (a
U Q F- O
2
U
Q
NtTti
TQT VTJ
0') VJ
C'7 Ch
(Y) (Y)
IN,
CL a ^,
I L c CD -W
O = (n cov1
N IL Q
C '~ U1 L ❑ C
a) C Ocm .0
U U U �
C2Ln
U O N C E
U U >1
LO
C\j� ® N a)
U 'a O
Y c - E v
O Q (n cm U Elcn
._ co
Y = a) El 1:1O L a
U 2 Q a) a 0�ai O a�
mV c > M N ❑ Q c6 cu cB
N a a_ �' cn L o
o rn
Q U _ E cu
a) L o U
H U N = 0 N 'a C
W w w m L ®❑ v m m rLa.
n- w °' a) ❑ - ❑ ° c J' -
LU O LL �I >
cu aa) Q m o [
CL L 2: cn�_ *cJ
cn a a _CD °
J Lo :3OLL El❑ ElN � �O
o Nu w d w ® Q ❑ '� cJ
Na" Fn L, ❑
0 3 N Cl) Cf)> eci
a) -0 OW _W v
m OQ Q Y m Z a L
°� cn o } Z O
Q cn O
Qw LL LL a a'��
O 0 cn LU W^
L i i L .r ^ /LLj- 4--
/Q
U�
U J O I-" cw Q coQ > a) (D V) a) ^
a
x >+ O m O
N L6 cfl W m 0
COSA Checklist.docx
COSA Checklist
Legal Description: LAMPERT ESTATES BLOCK 2, LOT 8 Parcel ID: 051-791-09
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA - PUBLIC &/OR CLASS “A” WATER
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in 1st septic tank 50”
Date of pumping 4/18/24 – (BOTH TANKS)
Required maintenance completed, if AWWTS
Comments: SECOND TANK IS STEP
C. LIFT STATION
Required maintenance completed
Age of lift station 4 years
Lift station material HDPE / PLASTIC
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 7/18/2013
ALL standpipes present per record drawing
Total measured depth from existing grade 6.7 ft (max)
Measured depth to pipe invert from grade. ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective (ED).
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date 4/19/2024
Results Pass
Fluid depth prior to test 19 in
Water added 800 gal
New fluid depth 29 in
Elapsed time 120 min
Final fluid depth 19 in
Absorption rate 750 gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) 42 in (MOA 3.5’ ED)
Effective depth used 19 in (Final Fluid Depth)
Effective depth remaining 23 in
Comments/Deficiencies: Approximate total measured depths from existing grade. ED per elevation measured shots &
appears approximate.
COSA Checklist.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) - NA
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date 4/30/2024
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
04/30/24
MUNICIPALITY OF ANCHORAGE
Development Services Department
04
_._��-' Phone: 907-343-79
On -Site Water & Wastewater Section Fax: 907-343-7997
Lift Station/Pump Vault
Maintenance Log
Owner �P Ile c t rk it pj_ sok
Septic Tank:
-Sludge level inches
Street Address 2 2 S YS Lo, / j
-Pumping: required es
Lift station:
*Pump basket cleaned es no
*Control floats cleaned es no
*Operation satisfactory es no
Alarm System:
-Pumping completed Qes no
*Effluent filter cleaned yes no
*Proper float settings confirmed @)-no
Dedicated electrical alarm circuit e' no -Audible and W&eaf alarm inside dwelling es no
-Alarm system operation satisfacto not satisfactory
Manhole Riser
*Ground water intrusion at riser to tank connection yes no
*Ground water intrusion around pipe penetrations Ves
-Manhole lid: Functional e no Insulatedno
Other
*Weep hole functional e no
Properly Secured e no
-All manufacturer required inspections and maintenance completed yes no
Comments:
Qualified Maintenance Provider:
Technician T �n— Date of maintenance
Company
Signature Date
RUs�
MUNICIPALITY OF ANCHORAGE�r
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section \` -' Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 051-791-09
1. GENERAL INFORMATION
Expiration Date: l `- � -2d-2D
Complete legal description LAMPERT ESTATES BLOCK 2, LOT 8
Location (site address) 22545 LAMPERT CIRCLE, CHUGIAK, AK 99567
i
Current property owner(s) BRIAN & DEANNA CARTER Day phone
Mailing address
Real estate agent
1840 N HONEYSUCKLE CIRCLE. ANDOVER, KS 67002
2: TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
5
Day phone
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
❑
Private Septic'
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
®
Public Sewer 1.
❑
Waiver request for:
Distance:
Received by:
Date:
COSA to be released to the engineer, unless otherwise
requested by the engineer.
COSA Fee $ ?3 19 b j QUO Waiver Fee $
Date of Payment (a(, to f�y� Date of Payment
Receipt Number 0gl(p)3% Receipt Number
COSA# Waiver#
COVID-19
20' DISCOUNT APPLIED
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below,, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Address 13030 SUES WAY, ANCHORAGE, AK 99516
Engineer's Printed Name CURTIS HUFFMAN, PE Date 6/4/2020
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to s +4 or -..
these various and dynamic characteristics and are outside the control of the evaluator of the •(�(i
well and septic system. Therefore, any estimate of how long a system will function satisfactory �'���P• • • • •
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting & FW(S ' *• -49 TH , , , ,.;* �IJ/
6. DSD SIGNATURE �� •
_ • . Curtis Huffman
System #1 Approved for bedrooms �f�9�s•, CE 128991
System #2 Approved for bedrooms i1�PROFESSIQ0
i
Disapproved
Conditional approval for bedrooms, with the following stipulations:
OF'g'y�ti''����
. '1�7
g ER AND
T
J
J /
J
,1)J,, ?wr Seo pll% \,;S,
5:
3
By: `' Original Certificate' Date:�� r g�Z0-20
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
Other w,.�
Legal Description: LAMPERT ESTATES BLOCK 2, LOT 8
If more than 1 septic system on lot: COSA Checklist # _of
A. WELL DATA — PUBLIC WATER
❑ Well log is filed with Onsite (or attached)
Date drilled
Total depth _ft
Cased to _ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground) _in.
Date of flow test for COSA
Static water level at beginning of test _ft.
Comments
B. TANK DATA
Age of tank(s) 25 years
Tank type/material SEPTIC / STEEL
Measured operating fluid level in septic tank 50"
® Standpipes/foundation cleanout per record drawing
Date of pumping 6/4/20
D. ABSORPTION FIELD DATA
Which system tested (date installed) 7/18/2013
® ALL standpipes present per record drawing
Total measured depth from grade 6 ft (max)
Measured depth to pipe invert from grade _ft (min)
® N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
® Code -required soil cover over field
❑ System presoaked
(Required if vacant for greater than 30 days prior to
date of test)
Gallons introduced gallons
Comments/Deficiencies:
Parcel ID: 051-791-09
Structure served by this system
Well production at time of test _gpm
Water storage tank volume_ gallons
Well disinfected for coliform test? ❑ Yes ❑ No
❑ Coliform bacteria is Negative
Nitrate _mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by
Date of Sample
C. LIFT STATION
® Required maintenance completed
Age of lift station 7 -years
Lift station material
Comments: See attached MOA tank advisory.
Adequacy test date 6/4/2020
Results JZ Pass For 5 bedrooms
Fluid depth prior to test 16 in
Water added 750 gal
New depth 21 in
Elapsed time 1260 min
Final fluid depth 16 in
Absorption rate 750 gpd
Any rejuvenation treatment (past 12 months) N
If yes, enter date
FW'GS
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station on Lot > 100'
® Yes if No ft
Wells on Adjacent Lots:
Community Sewer Manhole/Cleanout > 100'
® Yes
if No
ft
® Yes
if No
Neighboring Tank > 100' ® Yes
if No
ft
Private Sewer/Septic Line > 25' ® Yes
if No
Absorption Field on Lot > 100' ® Yes
if No
ft
Holding Tank > 100' ® Yes
if No
Neighboring Absorption Fields > 100'
Surface Water > 100'
® Yes
Animal Containment > 50' ® Yes
if No
® Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ® Yes
if No
ft
® Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10' ❑ Yes if No 5'+ ft Surface Water > 100'
ft
ft
ft
ft
ft
® Yes if No ft
Property Line > 5'
® Yes if No ft
Wells on Adjacent Lots:
Absorption Field > 5'
® Yes if No ft
Private Wells > 100' ® Yes if No
Water Main > 10'
® Yes if No ft
Community Wells > 200' ® Yes if No _
Water Service Line > 10'
® Yes if No ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
® Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
® Yes
if No
_ ft
Wells on Adjacent Lots:
Water Main > 10'
® Yes
if No
ft
Private Wells > 100' ® Yes if No ft
Water Service Line > 10'
® Yes
if No
ft
Community Wells > 200' ® Yes if No
Surface Water > 100'
® Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
! certify that l have determined through field inspections and review �": •' • . :� ��
of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date. : ir
....�r
...... ...�......
• Curtis Huffman
9F,9 CE 128991 �����N
1A. FAFO'°ROFESS VO��� .m
ft
ft
MUNICIPALITY F ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section �- '` Fax: 907-343-7997
Lift Station/Pump Vault
Maintenance ggg
Owner Street Address c , �,j �, c>,M
Septic Tank:
-Sludge, level J0 inches -Pumping: required es no -Pumping completed es no
Lift station:
-Pump basket cleaned Qes no -Effluent filter cleaned es no
-Control floats cleaned e no Proper float settings confirmed e no
-Operation satisfactory e no
Alarm System:
-Dedicated electrical alarm circuit es no -Audible and visual alarm inside dwelling es no
-Alarm system operationsatiisfacto not satisfactory
Manhole Riser
-Ground water intrusion at riser to tank connection Les Co
-Ground water intrusion around pipe penetrations yes no -Weep hole functional es no
-Manhole lid: Functional es no Insulated es no Properly Secured (yesN no
Other
-All manufacturer required inspections and maintenance completed es no
Comments:
Qualified Maintenance Provider:
Technician
Company _L +S. 5 ery t Q— c�
Signature
Date of maintenance(L) W
Date_� aUhe gz
Septic 'Tank Advisory
Certificate of On -Site Systems Approval #OSC201232
Subdivision: Lambert Block 2 Lot 8
Starting at 20 years of age the MOA issues Advisory's for steel septic tanks. The septic tank for
this property is 25 years old. Typical replacement costs range from $8,000 to $11,000.
This advisory must be attached to all copies of the subject Certificate of On -Site Systems
Approval.
This is an example of what the metal of a 20 year old steel tank MAY look like.
Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 051-791-09-000
1. GENERAL INFORMATION
Complete legal description Lampert Estates BI / Lt 8
Expiration Date: 7 - J,C_-) 5
Location (site address) 22545 Lampert Circle, Chuqiak, AK 99567
Current Property owner(s) Carl & Mildred McIntyre Day phone
Mailing address 22545 Lampert Circle; Chuqiak, AK 99567
Real Estate Agent Day phone
2. TYPE OF DWELLING:
Z Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 5
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well ❑ Individual
Individual Water Storage ❑ Holding Tank ❑
Community Class Wail ISI Community Li
Public Water System ® Public Sewer ❑
WaiverNariance request for: Distance:
Received by:
I i.
COSA to be released to the engineer, unless othenyise rf quested by the engineer.
Date:
COSA Fee $ 250.00
Waiver Fee $
Date of Payment 7! )A 1p3q
1Date of Payment
Receipt Number /69',.! 0 O 9- Receipt Number
COSA# 05CL313f5 Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm ARCTERRA CONSULTING, INC.
Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577
Engineer's Printed Name KENNETH M. DUFFUS
Phone 696-6111
Date 7/27/2013
Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the
condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to
subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that
may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic
systems are subject to these various and dynamic characteristics and are outside the control of the
evaluator of the well and septic system. Therefore,
ArcTerra can not give any estimate of how long a
system will function satisfactory for current or future
occupants or can ArcTerra guarantee that no unseen
encroachments, deficiencies or discrepancies exist.
6. DSD SIGNATURE
System #1 Approved for 5 bedrooms.
System #2 Approved for bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
vt(tOF fyctiI?,,i
0
\MA ER AND fir
WASTEWATER oz
PROGRAM to-
cc
o-
,Arr sER\I 0
Original Certificate Date: 3 -'S / a
The- u p. ft,,i: nchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet 10-10-12.doc
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system 1
Certificate of On -Site Systems Approval Checklist
Legal Description: LAMPERT ESTATES BLK 2 LT 8 Parcel ID: 051-791-09-000
A. WELL DATA
Well type PUB If A, B, or C provide PWSID # _ Well Log (Y/N) N
Date completed N/A Sanitary seal (Y/N) N Wires properly protected (Y/N) N
Total depth N/A ft. Cased to N/A ft. Casing height (above ground) N/A in.
FROM WELL LOG AT INSPECTION
Date of test NA NA
Static water level NA ft. NA ft.
Well production NA g.p.m. NA g.p.m.
WATER SAMPLE RESULTS:
Coliform NA colonies/100 mL Nitrate NA mg/L
Arsenic: NA ug/L
Date of sample: NA Collected by: NA
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC I STEEL Date installed 7/7/1995
Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (YIN) Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping 511/13 Pumper JRs Pumping
C. ABSORPTION FIELD DATA
Date installed 07/18/2013 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.6 System type TRENCH
Length 137 ft. Width 5 ft. Gravel below pipe 3.5 ft.
Total depth 6.0 ft. (Measured 7/17/2013) Eff. absorption area 1295 ft2 Monitoring tube Y Depression over field N
Date of adequacy test NEW SYSTEN Results (Pass/Fail) NA For 5 bedrooms
Fluid depth in absorption field before test NA in. Water added NA gal. New depth NA in.
Elapsed Time: 0 min. Final fluid depth 0.0 in. Absorption rate >= NA g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
D. LIFT STATION
Date installed 7/18/2013
Size in gallons 500 Manhole/Access (Y/N) Y
"Pump on" level at 44 in. "Pump off' level at 42 in. High water alarm level at 48 in.
Datum bohlitnio.P K Cycles tested Meets alarm & circuit requirements? Y
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot NA
Absorption field on lot NA
Public sewer main NA
PUBLIC WATER
Sewer /septic service line NA
Animal containment areas NA
On adjacent lots NA
On adjacent lots NA
Public sewer manhole/cleanout NA
Holding tank NA
Manure/animal excrete storage areas NA
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main 10'+ Water service line 104- Surface water 100'+
Wells on adjacent lots 100'+
ABSORPTION FIELD ON LOT TO:
Property line 10'+
Water Service line 104 -
Building foundation 10'+ Water main 10'+
Surface water 100'+ Driveway, parking/vehicle storage 10'+
Curtain drain 50'+ (NONE KNOWN)
F. COMMENTS
Wells on adjacent lots 100'+
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this date.
Engineer's Printed Name KENNETH M. DUFFUS
Date 7 /a 7/65
COSA brown sheet 10-10-12.doc
PROPOSED Flp141E0 FLOW
ELEV. (AsSuPEO)
PROPOSED CU'.:OING CORNER
E1£V. (A5NREW)
ZONING OSmICT
N80' 58' 50"W 206.00'
FRONT BUILDING ETBAW
10' UTIL ESMT N
SCE BUILOKG SETBACK
C.O.
REAR BUILDING SETBACK
C.O.
_
'.
7.5
G
IT? 28.0'1
44.5' — co
O
N EXISTING cos.1M.H.
HOUSE o % —° T5
\\
-___D,44 - 5.' _ py
o s
28.0, Il�1rj
iff
9
e
/ a
r
UNDER NO CIRCUMSTANCES SHOULD AN AS -BUILT BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES.
THE SURVEYOR TAKES RESPONSIBILITY FOR THE INITIAL 1RANSACTION ONLY AND ASSUMES FINANCIAL LIABILITY ONLY FOR THE COST OF THE SURVEY.
LISTED DISTANCES PREVAIL OVER SCALING. REPRODUCTION MAY CAUSE ERRORS IN SCALE.
Cl
❑
it
LOT SURVEY SURVEY TYPE
SYMBOLS
SET REBAR DasnxG PROPOSED
Sizto DRAINAGE I.,Ars°.p{ ASPHALT
O FOUND REBAR �`- i CONCRETE
FOUNDATON AS -BUILT
FINAL STRUCTURE AS -BUILT
PLOT PLAN ... AS -BUILD ... LOT SURVEY ... TOPOGRAPHY
AS -BUILT . NO CORNERS SET '' RECERTIFlCATON AS -BUILT... NO CORNERS SET
° 0 0 WOOD FENCE
OOT ASSUMED ELEV. I /1111
X X X METAL FENCE WOOD DECK
PLOT PLANS & LOT SURVEYS
NOTE:
ONLY THOSE IMPROVEMENTS ABOVE GROUND AND VISIBLE WILL BE
SHOWN. FENCE:S, WELLS. SEPTIC CLEANOUTS, SIDEWALKS, DRIVEWAYS,
ETC.. ARE SHOWN IN THEIR APPROXIMATE LOCATION, ONLY. SNOW
MAY PREVENT SOME IMPROVEMENTS FROM BEING SEEN AND LOCATED.
ALL DISTANCES ARE RECORD UNLESS OTHERWISE NOTED.
IT I5 THE RESPONSIBILITY OF THE BUILDER OR OWNER, PRIOR TO
CONSTRUCTION, TO VERIFY PROPOSED BUILDING GRADE RELATIVE
TO RNISHED GRADE AND UTLITY CONNECTIONS AND TO DETERMINE
THE EXISTENCE OF ANY EASEMENTS, COVENANTS OR RESTRICTIONS
WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT.
SURVEY CERTIFICATION
m®'6,Ytwah@Hd4_
®®'�-C� 9. /1
®•.0 P``,,
• \ •4p°
! �•
® '4 ^ ...
p r•
fig®
•<. ;QST®�
i
l
Prepared by
Ro9ert E. Johns, Jr. & Assoc.
Professional Land Surveyors
1700 Brink Drive.
ANCHORAGE, ALASKA 99504
PLOT PLAN
IM1vaby c.rNf that I haW phni=ally.—yad
the lot drown d ae TM hereon, and that
how found or aatublshed di of the ,t my
in shown on the pion and to N. beet of my
Moo<dge and nbeluew all d.meet how boon
measured true Ona current.
FOUNDATIC4 AS BUILT
i. Roat,A E. aohne..t.hereby certify that I
w pN i Bet survey M N.
have
foundation d thatol Na /
&monot : Informaticn Oy than,: hereon
are w r.o<d,mente east unless
«h�•laa
FINAL STRUCTURE AS -BUILT
I, RWM E. &nit an, hereby Not I
perleemed an Ae—DUAL y-twy of the
structure on thl' lot nm that di the
dmx.elma and nlumaRon . shown hereon
mint..,add
thew °se;.
Scale: ,� n = 40�
Rec. Lot S.F.
Rec. Plat File No.
Ill�J°°'ea
-
°.
�
•SJiR
1CI
• 1
gR°O•BC°R"T E. ...°r°`
®mr12tif...az,i.41'
0
e 6'�
�e69100a‘®
trawa,®
Dat. Surveyed: 07/1 7i
Drawn by REJ
Checked by
M K
Date Drawn:
07/17/13
Grid:
1459
W.O.
13-323
Lege! Description:
Lot 8 BLOCK 2
LAMPERT ESTATEScG°,�
Municipality of Anchorage
Department of Health and Human Services
Division of Environmental Services
On -Site Services Section 825 "L" Street Room 502
P.O Box 196650 Anchorage, AI<' 99519-6650
www.ci.anchorage.ak.us
(907)343-4744
ERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY. DWELLING
Parcel I.D. 051-791-09
',GENERAL.INFORMATION
Complete legal descnption Lampeit Estates L8 B2
site addressor directions) 22545 Lampert Circle Chugiak AK 99567
HAA # /l�v6U 7
Expiration Date
Location
Current Prope
Mailing address
Lending°agency,
Mailing address
Real Estate Agent
Mailing Address
owner(s) "James Rosin
6 OV Cu7049
Day phone
Cl.t utak, 995(v
Day phone
Day phone
Unless otherwise requested, HAA will be held by DHHS for pickup. HAA picked up by:.
▪ NUMBER OF BEDROOMS: 5
▪ TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class A Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:',
Individual On-site Z
Individual Holding tank`
Community On-site
Public Sewer
111
The Municipality of Anchorage Department of Health and Human Services (DHHS) Issues Certificates of Health
Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent. professional
civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer
of title (except between spouses) on properties served by a single family on-site wastewater disposal and/or water
supply system. DHHS also issues HAAs upon request to home owners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results less than 30 days old. Certificates are valid for one year for properties served by Class A
or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
(Rev. 11/99)
5: STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation
based on procedures outlined in the Health Authority Approval Guidelines for this Health Authority Approval
application shows that the on-site water supply and/or wastewater disposal system is safe, functional and
adequate for the number of bedrooms and ,type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-
,. site water supply and/or wastewater disposal system is in compliance with all applicable Municipal and State
codes, ordinances, and regulations in effect at the time of installation.
Name of Firm 101f1Fmmnenrinn Phone 898-8111
Address 90441 Ptarmj..
Engineer's Printed Name Kenneth nuffua
6. DHHS SIGNATURE
Approved for
Disapproved.
By.
bedrooms.,
Date 8/29/00
OF Az
/ *-49
4Aw
E //�
KEENED j4 3-..
CE 711- 4. if
S41)0
p�N
FESSIOPS' '
\`o -
Conditional `approval for bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist X
Septic System Advisory
Well Flow Advisory
W, (c) 0-e.t
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date. %— - 0 o
Expiration Date' q— 10 " 0 1 Reissue Dates
(Rev. 11/99)
Municipality of Anchorage RECEIVE
Department of Health and Human Services
Division of Environmental Services AUG 3 1 2000
On -Site Services Section 825 "L" Street Room 502
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us MUNICIPALITYOFANCHORAGE
(907) 343-4744 ENVIRONMENTAL SERVICES DIVISION
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: Lampert Estates L8 B2
Parcel I.D.: 051-719-09
A. WELL DATA �t
Well type community A If A, B, or C provide PWSID #floqri Well Log
Date completed Sanitary seal Wires prop y protected
Total depth ft Cased to ft Casing height (a ve ground) in.
FROM WELL LOG
Date of test
Static water level
Well production /
WATER SAMPLE RESULTS:
AT INSPECTION
ft / ft
g.p.m / g.p.m
Coliform colonies/1 0 ml Nitrate mg/I Other bacteria colonies/100 ml
Date of sample: Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Steel
Date installed 7/7/1995 Tank size 1500 gal Number of Compartments 2
Cleanouts y Foundation cleanout y Depression over tank n High water alarm na
Date of pumping 8/23/2000 Pumper JR's Pumping
C. ABSORPTION FIELD DATA
Date installed 1/10/615 Soil rating (g.p.d./f12 or ft2/bdrm) 0_6 System type deep trench
Length 107' ft Width 2.5' ft Gravel below pipe 6 ft
Total depth 10' ft Effective absorption area 1284 ft2 Monitoring tube y Depression over field n
Date of adequacy test S/2.3/b D Results (Pass/Fail) pass* For 5 bedrooms
Fluid depth in absorption field before test 23 in Water added750 gal. New depth37 in.
Elapsed Time: 1440 min Final fluid depth 23 in Absorption rate >= 750 g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) no If yes, give date
(Rev. 11/99)
D. LIFT STATION
Date installed Size in gallons
"Pump on" level at in" Pump off' level at in
Datum Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL O LOT TO:
Septic tank/lift station on lot On adjacent lots
Absorption field on lot On adjacent lots
Public sewer main Public sewer manhole/clea .ut
Sewer /septic service line Holding tank
Manhole/Access
High water alarm level t in
Meets alarm & circuit equirements?
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 101+ Property line 10'+ Absorption field 10'+
Water main 25'+ Water service line 15'+
Drainage 1001+ Wells on adjacent lots 200'+
Surface water 1001+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 13' Building foundation 10'
Water Service line 25'+ Surface water 1001+
Curtain drain 100'+ Wells on adjacent lots 2001+
F. COMMENTS
*Field operational in top 4' of trenchonly
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed Name
8�2 00
Date
Kenneth Duffua
Water main 2''+
Driveway, parking/vehicle storage 25'+
i ,oOF-ALA
/0\ .1
1,49
KENNE
D
CE-711fil
S'
4
d;s41
N,L�/
N, r'RDFEssio0v
HAA Fee $
Date of Payment
r/c %4'0
Receipt Number U/ ;n 7)
(Rev. 11/99)
Waiver Fee $
Date of Payment
Receipt Number