HomeMy WebLinkAboutPARADISE VALLEY BLK 8 LT 12AParadise Valley Block 8 Lot 12A #020-413-41 Permit Number: Tax Code Number: Work Type: OSP101263 O2041341000 Well On-Site Water System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Upgrade Permit Effective Dates: November 18, 2010 to November 18, 2011 Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING Subdivision: PARADISE VALLEY Site Legal Address: PARADISE VALLEY BLK 8 LT 12A G:3538 Owner/Address: FOWLER WILLIAM & HELEN 6101 ROMANIA DRIVE ANCHORAGE AK 995066014 Site Mailing Address: 6101 ROMANIA DR, Anchorage Lot Size in Sq Ft: 41119 Total Bedrooms: 4 This permit is for the construction of: N Disposal Field N SepticTank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: The well location shall be flagged by a licensed land surveyor. The land surveyor shall verify the well is located 100 or more feet from the drainfield on Lot 9 and the septic tank on Lot 11. Special Provisions: Permit includes waiver OSP101272 allowing the well to be 92 feet from the subject property's septic system drainfield. Date: Date: Municipality of Anchorage P.O. Box 196650 · 4700 Elmore Road Anchorage, Alaska 99519-6650 · (907) 343-7904 · Fax (907) 343-7997 http:llwww.muni.orglOnsite Development Services Department On-Site Water and Wastewater Program : par t.~nent **** VARIANCE/WAIVER REVIEW **** WR#: OSP101272 HA#: Permit#: OSP101263 PID#: 020-413-41 Legal Description: Paradise Valley, Block 8, Lot 12A. Engineer: Mike N. Anderson Applicant: William & Helen Fowler Your request for a waiver of the required 100 feet horizontal separation from the absorption field to the private well has been approved. The approved separation distance is 92 feet. This waiver approval apPlies to the existing absorption field to private well separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Waiver is Granted: X Waiver is not Granted: 1/18/2010 Approved by'~. Date: 1 Name of Reviewer Recg: 137433 Amount: $1,050.00 Date Paid: 11/1212010, **** VARIANCE/WAIVER REVIEW **** Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99507 www. muni.org/onsite (907) 343;7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Property owner(s) Mailing address Site address Legal description (Sub'd., Block & Lot) Po Legal description (Township, Range & Section) Lot Size Sq. Ft. Day phone Zip Code .Zip Code Number of Bedrooms THIS APPLICATION IS FOR ([~ all that apply): Absorption Field Septic Tank Holding Tank Privy Private Well Water Storage THIS APPLICATION IS AN: Initial [] Upgrade ~ Renewal [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: (Rev. 11/05) Waiver Fees: Date of Payment: Receipt Number: Michael N. Anderson, P.E. Civil/Structural Engineering & Construction 4661 Natrona Avenue Anchorage, Alaska 99516 Phone 345-3377 Fax 345-1391 Nov. 2,2010 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 Re: Paradise Valley Subd. Blk 8, Lot 12A To Whom it may concern: Attached is an application for a new water well permit on the referenced lot. The existing well has caved-in and is over 600 feet deep therefore the owner is requesting a new well be installed. From the site plan it is tight but the new well can be installed and not encroach on the neighboring septic systems to the north and east. The site was surveyed by Arctera, John Schuller, LS and the new well location was staked by him also. If you have any question please call me at 727-8864. Michael N. Anderson, P.E. Civil/Structural Engineering & Construction 4661 Natrona Avenue Anchorage, Alaska 99516 Phone 345-3377 Fax 345-1391 Nov. 10,2010 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 Re: Paradise Valley Subd. Blk 8, Lot 12A, Waiver Request To Whom it may concern: This is an application for a waiver for the proposed new water well on the referenced lot. The existing well has caved-in and is over 600 feet deep therefore the owner is requesting a new well be installed in the NE corner of the property. The site plan was surveyed by Arctera, John Schuller, LS. Two septic systems surround the proposed new well location, lot 9 and lot 11. Justification for the 8 foot waiver is as follows: 1. No other locations available has water. The current location has two dry wells. 2. According to the current survey the leach fields on lot 9 & 11 will not be encroached, only the existing system on lot 12A. 3. The gradient from the 3 surrounding septics is downhill from the new well site. 4. The well logs from lot 9 & 11 are 255' & 287' with tight confining layers, which would prevent contamination from reaching the water table. 5. The nitrate level in the surrounding wells is 7.4 & 6.6 mg/L which is below the MOA limit of 10mg/L. With these given reasons we are requesting a waiver of 8 feet to the leach field on lot 12A. If you have any question please call me at 727-8864. Michael N. Anderson, P.E. LOT 14 EXISTING SEPTIC GRAVEL DRIVEWAY TO REMOVED OVER LEACH RELD LOT 12A BLK 8 s~c_~° EXISTING HOUSE / EXISTING SEPTIC / / SHED HAS SKIDS FOR FOUNDATION LOT 1( EXlSRNG WELL 100' RADIUS, WEll LOT 11 ~ / / ID(ISTINO WELL TO BE DECOMMISSIONED ,,~ PER'-N~.C.. 15.55.060 - Septic Design Prepared for BILL FOWLER PARADISE VALLEY, BLK 8, LOT 12A Anchorage, Alaska Michael N. Anderson, 4661 NATRONA DRIVE ANCHORAGE, ALASKA 99516 PH. 545-5.377 / FAX: 545-1591 P.E', DATE: DRAWN: SCALE: 11/3/2010 D JR 1"=50' EXISTING SEPTIC MUNICIPALITY O~ ANCHORAGE PLA~ING AUTHOPJT¥ RESOLUTION NO. 2000-18 ANCHORAGE RECORDING DISTRICT A RESOLUTION APPROVING A REQUEST TO ELIMINATE AN $8-FOOT SEPTIC SETBACK EASEMENT AND TO REMOVE A PLAT NOTE THAT PROHIBITS THE INSTALLATION OF A SEPTIC TANK OR AN ABSORPTION FIELD WITHIN THE SEPTIC SETBACK EASEMENT ON LOT 12A, BLOCK 8, PARADISE VALLEY SUBDIVISION (PLAT 95-27) WITHIN THE SW ¼ OF SECTION 11, T11N, R3W, S.M., ALASKA, LOCATED ON THE NORTH SIDE OF ROMANIA DRIVE AND WEST OF SPAIN DRIVE. WHEREAS, a request has been received from Bill and Helen Fowler to eliminate an 88-foot septic setback easement and to remove a plat note that prohibits the installation of a septic tank or an absorption field within the septic setback easement on Lot 12A, Block 8, , Paradise Valley Subdivision (Plat 95-27) within the SW 1/4 of Section 11, T1 IN, R3W, S.M., Alaska, located on the north side of Romania Drive and west of Spain Drive, and cr~ ~o~'n WHEREAS, notices were published, posted and mailed and a public hearing was held ~ August 2, 2000. NOW, THEREFORE, BE IT RESOLVED by the Platting Authority that: 1. The Platting Board makes the following findings of fact: The septic setback easement and plat note were applied to the plat recorded in 1995. The easement was originally required because of drainage within the ditch adjacent to Romania Drive. The Department of Health and Human Services (DHHS), in a subsequent review of this property, determined that this setback is no longer required. Based on comments from DHHS, the Board found that the requested amendment to Plat 95-27 could be approved. The Board APPROVES the elimination of the 88-foot septic setback easement and removal of the note prohibiting a septic tank or an absorption field within the easement subject to recording a resolution at the State District Recorder's Office. m APPROVED by the Anchorage Platting Aut ay Susan Fison, Don -Poulton, Secretary Chair of August 2000. Case S-9560-2 Rcturn to: Municipality of Anchorage Dept. Community Planning &, Development P.O. Box 6650 Anchorage, AK 99519-6650 Attn: Margaret O'Brien ¢' \ eo$~$g Municipality of Anchorage Department of Health and Human Services Division of Environmental Services On-Site Services Section 825"L" Street Room 502 P.O. Box 196650 Anchorage, AK 99519-6650 Page of www. d.anchorage.ak.us (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ua~: ~:~ ~ ~[~ ~t~ WastewaterSystem: ~New ~Upgrade ~-~ ~/e ~r~¢~ ABSORPTION FIELD Block:~ LO': j~/,~~,~,SubdMs?;: ~/;~ Dep,htopT~bog~fromodginalgmde:~ Ft. Gmveldep,hbeneathpye: ~ FL Township: ~nge: Secliom Fill added above odglnal ffade: Grave~ Length: SEPARATION DISTANCES ~ septic ~ Holding ~S.T.E.P. D O~er: ,,-,,, .T~° Septic Absorptior Lift Helding Publi~Hvate ManuracUrer~,l ~ Capacity: Tank Field Station Tank Sewer Line ~g, ~ / ~ GaL Enginee~s Stamp Depmlment of Health and Human Se~ices apprbval ~~. ,~,~ J: ,~ AS-BUILT SYSTBH ]}ETAIKS/SITE PLAN Pe~r~i~ swsso4ss PARADISE VALLEY S/D, ]98, L12A PID~OaO-413-41 12 ~ ~ LB'r 11 A-C=32,8' = = j ?-D=Sa7 A-E=78,3' ~ ~~ N ~ [DOO GAL ~ I B-g=63'3' p / STEP Xx' ,,'~ ...... SEWER ROCK ~.~, * FINISHED GRADE ~ SEWER ROCK .to, BILL & HELEN FBWLER 30-341 A CHERRY DR,, APT, 8 ELNENDORF, AK 99506 FIELD BOOKS COMPU TEO: ENGINEERING BOUNDARY: S* HOLT ORA~N: KMD sr^x,uo: $. HOLT OH£CKEO: KMD 20441 PTARMIGAN BLVD. ASDUILT: S. HOLT DAn-: 2/14/00 EAGLE RIVER, AK 99577-8736 3538 ncaa r,m 96061 aos .o.: 96061 ¢907/696-6111/FAX '907~696-6111 iKN1D ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 Performed for: PERCOLATION RE-TEST Bill & Helen Fowler Date Performed: Project: Paradise Valley B8, L12A TEST HOLE # 96-1 Depth (Feet) SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? NO Whatdepth? NA Depth to water after monitoring? NA Date? NA 5- 6- 7- 8- 9- 10- 11- 13- 14- 16- 18- HOLE PRESOAKED PRIOR TO TEST Reading Date Gross Net Depth to Net Time Time Water Drop i 9/10/99 11:00 7" 2 11:10 10 min 5 6/16' 1 10/16' 3 * 11:11 7" 4 11:21 lOmin 5 10/16' 1 6/16" 5 11:22 5 10/16' 6 11:32 10 min 4 7/16" 1 3/16" 7 * 11:33 7' 8 11:43 10 min 6' 1" 9 11:44 lO 11:54 10 rain 5' 1' 11 11:55 5" 12 12:05 10 rain 4' 1' · Water Added 19- 20- Percolation Rate 10 (mtn/in) Perc Hole Diameter 6' Test Run Between 3 feet and 4 __ feet I, Kenneth M. Duffus, certify that this test was performed hr accordance with all State and Municipal guidelines in effect on this date. ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 II Performed for: Project: Depth (Feet) SOILS PERCOLATION TEST Bill & Helen Fowler Date Performed: Paradise Valley B8, L12A TEST HOLE # ORG - brown, moist 09/10/99 99-1 SEE ATTACHED SITE PLAN FOR HOLE LOCATION 15- 16- 17- 18- 19- 20- GM- sandy gravei w/some silt looser at top w/cobbles to 10" -- B.O.H. HOLE PRESOAKED PRIOR TO TEST Was Ground~vater encountered? NO What depth? NA Depth to water after monitoring? NA Date? NA Reading Date Gross Net Depth to Net Time Time Water Drop i 9/10/99 1:00 6" 2 1:10 10 min 4 8/16' 1 8/16" 3 * 1:11 6" 4 1:21 10rnin 4 13/16' 13/16" 5 1:22 4 13/16' 6 1:32 10 rain 3 13/16" 1" 7 * 1:33 6" 8 1:43 10 min 5 1/16' 15/16" 9 1:44 5 1/16' 10 1:54 10 rain 4 2/16" 15/16" 11 1:55 42/16" 12 2:05 10 rain 3 3/16" 15/16" · Water Added Percolation Rate 10.7 (rain/tx) Perc Hole Diameter 6" Test Run Between 3.5 feet and 4.5 feet I, Ketmeth M. Duffus, certify that this test was performed in accordance with all State and Mnnicipal guidelines effect on this date. LOCATION/SKETCH: STATE OF ALASKA DEPARTMENT OF NATURAL RESOURCES DIVISION OF MINING & WATER MGMT WATER WELL RECORD SECTION TOWN4HIP WELL OWNER: DEPTHS MEASURED FROM:l-I~asing top'Fqground surface ,,BOREHOI~E, DATA: ......... Dep~th ,, ;, WELL DEPTH: )eptl DATE OF cOM'PLETION DEPTH.TO STATIC WATER LEVEL: /~:~'~' ' ft below '~to~'~f'c~sing ~ ground surface Date: METHOD OF I~RILLING: ~ air rotary [] cable tool [] ott~a~ USE'OF WE[.L: ~domesti~' [] irrigation ~[~ monitor [] public suppl? [] other :' ' CASING Srl, CK-ti": ~1~ ft. Diem; Lin, to ft Ca~ing tKO. ~. ,~,~-~r~ ~. tO ~ft WELL INTAKE OPENING TYPE: )erforated E~openend r-lscreenea ' DEVELoPMENTi: M~E . DU~tiS~i ; LEVEL AND,YIELD; . ft afte.r.. ~/ hfs pumping RUMP; NTAKE DEPTH= . ' ft HorsepoWer= WELL. DISINFEOTED ~ I ': "~ ~ / ~.' ,.f7 .";"~?;~E'; ~*~ ~ PLEASE MAIL WHITE COPY OF LOG TO: · o../o ws ou OF & WATER U UT Signature of Author zed Respres~ntat ve Mate .... - __ ~ ~ ,g~O ' ' '.,~ :~;~ ??)~ ~< Ancho~age, A~ 99503-5935 ~h(907)762-2538~ax(907)562-[384 MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Nov 12, 1998 Expiration Date: Nov 12, 1999 Permit Number: SW980439 Legal Description: PARADISE VALLEY BLK 8 LT 12A Design Engineer: 0070 KND Engineering Owner Name: WILLIAM & HELEN FOWLER Owner Address: 22-040 MAPLE STREET ELMENDORF AFB , AK 99506-3240 Parcel ID: 020-413-41 Site Address: 006101 ROMANIA DR Lot Size: 41449 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] SepticTank [~ Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AA072 ) and Drinking Water Regulations ( 18AA080 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~~ Issued By: ~-.-~'~~, ~/~¢¢-- Date: 11-12-? Rick Mystrom,, Mayor Muni_cipali of Anchor , ,c Department of Health and Human Services 825 'L' Street P.O. Box 196650 Anchorage, Alaska 99519-6650 http://www.ci.anchorage.ak.us 343-4744 May 29, 1998 William & Helen Fowler 22-040 Maple Street Elmendorf AFB, Alaska 99506 3240 Subject: Lot 12A Block 8 Paradise Valley Subdivision Permit #SW970110, PID #020-413-41 The subject permit, issued May 29, 1997 by this office for a single family well and/or on-site wastewater system, has expired as of May 29, 1998. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. Ail inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this office at 343-4744. On-site Services enc: Copy of Permit cc: KND Engineering PAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEAl, TH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT PERMIT NUMBER:SW970110 DESIGN ENGINEER:KND ENGINEERING OWNER NAME:FOWLER WILLIAM & HELEN OWNER ADDRESS:6101 ROMANIA DRIVE ANCHORAGE, ALASKA 99516 DATE ISSUED: 5/29/97 EXPIRATION DATE: PARCEL ID:02041341 LEGAL DESCRIPTION: PARADISE VALLEY BLK 8 LT 12A LOT SIZE: 41119 (SQ. FT.) NUMBER OF BEDROOMS: 4 THIS PERMIT: 4 THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDAMCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18A3~C80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. 1 OF 5/29/98 1 SPECIAL PROVISIONS RECEIVED BY: /~_ DATE ~ND ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 May 14, 1997 Municipality of Anchorage Dept. of Health & Human Services On-Site Services Section P. O. Box 196650 Anchorage, Alaska 99519-6650 Subject: New sewer/well permit ~ Paradise Valley S/D, Block 8, Lot 12A Gentlemen: On September 13, 1996, we excavated two testholes for the subject property. These were in addition to the existing two holes. The results of these tests and water monitoring are attached. We propose to install a 4' deep 5' wide trench. There was no water found after several monitoring periods spanning over eight months. The only water observed was in TS/TH#2 which has had fluctuating water since its original monitoring. Additional fill will be placed over the system to provide a minimum of 3' of cover when complete if required. There are no public or private wells within 200' of our proposed system location except as noted. There is neither surface water within 100' nor any known curtain drains within 50'. We do not expect that the surrounding lots, vacant or developed, to be adversely effected by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, II~.llgl/D Engineering Kenneth M. Duffus, P.E.'t attachments: On-Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test ' WAs-I-EWATER DISPFISAL SYSTEM OETAILS/SITB PLAN PARADISE VA~EY S/D, ES, LiRA MT SYSTEM DETAILS l"= 20' i 1/4· PVC FRB~ TaNK TB FIEL~ ,i MT MT ~ ,l/~,PVC 250 STEP TANK PRESSURIZED DISTRIBUTION SYSTEM HOLK SPACING DESIGN ~. HOLE SIZE = 3/16' = ~,00 GAL PER HOLE ~ 30 PSI 3. 30 GPM (PUMP DELIVERY)/1,O0 GALS,/HOLE = 30 HOLES 4. 75 LF L~TERAL/30 HOLES = 2.5' SPACING PER HOLE 5, ALL IIBLES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS. 6. HOLES AT END BF LATERAL SHALL BE CONST, W/B CAPS ANB PLACE~ BO~/N, 7, CONTRACTOR SHALL USE 1 ~/4' PVC PROM T~NK TO FIELD AN~ IN LATERALS, DESIGN DETAILS 4 BDRM X ~50 OPD = 600 6P~ 600 GPD/0,8 GP~ PER S~, FT, = ~50 S~. FT ~ 750/5'(4' GRAVEL) x 0.5(5 wide)= 75' Tpench c~ ?H~~ 4~ ~ PREPARED FOR: I<ND ENGINEERING ~ILL ~ HELEN FOWLER EAGLE R~VER, AK, 99577 --~ 3o-34t A CHERRY DR., APT, 8 ~O~sslOgB~ ~ (907)696 6111/Fox (907)696-8111 ~ ELHENDBRF, AK 99506 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 4- 5- 6- 7 8 9 10 11 12 13 14 15 16 17 18 19 2O Township, Range, Section: SLOPE SITE PLAN WAS GROUND WATER ,v ENCOUNTERED? IF YES, AT WHAT DEPTH? DeCh te Water After Monitoring? '~ S Gross Net Depth to Net Reading Date Time Time Water Drop ~ 9~13 -~0 ~/-o / --- ~ v/ed PERCOLATION RATE __ TEST RUN BETWEEN '/~/~0 (m,nutes/mch) PERC HOLE DIAMETER ~"~ /~ ~,~0 FTAND ~00 FZ 72-008 (Rev. 4/85) CERTIFY THAT THIS TEST WAS PERFORMED IN PERFORMED FOR: Municipality o! Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L'1 Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST LEGAL DESCRIPTION: DEPTH 2 3 4 7 8 9 I2 13 14 I7- 20- WAS GROUND WATER,~/v/~ ENCOUNTERED? IF YES, AT WHAT DEPTH? I]epth 10 Waler Monilorioo? /'Z"'~'/ Dale: COMMENTS PERFI Township, Range, Section: SLOPE SITE PLAN Gross Net Depth to Net Reading Date Time Time Water Drop ;,- ,t ~- ~ ,/~ ~- ~ '~/~ ,/~ PERCOLATION RATE /__/ (minutes/tach} PERC HOLE DIAMETER -- TEST RUN BETWEEN -~/.6~ PT AND ~,__D FT AOCORDAN CE WiT H ALL STAT~;~E AND M U~CICIPAL GUIDELINES ',~ EF F ECT ON Td'~/DATE DATE: 72-008 (Rev. 4/85) PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TES'r ~,~-! L..~, . LEGAL DESCRIPTION: L~"~ ~"~1 ~" I~ 2 10 ' Township, Range, Section: 11 13 '15 SLOPE 16 17 18 19 2O WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT ~) DEPTH? p E Deplh Io Water After Moflilodno? ] '~ Dale: SITE PLAN Gross Net Depth to Net Reading Date 'rime Time Water Drop ..~ ..6 ~5~.,.- ~l ~'/~ /.~ / ~ 15 '1~ PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN '~ FT AND "~Y~.. ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THiS DATE. DATE: PERFORMED FOR: LEGAL OESCRIPTION: 3 4 § 6 7- 8- 9- It 13 14- 15- 16- 17 18 19- 20- Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST Township, Range, Section: -j' Il ]~, J'~..;Z,~ I~.~ ~{;~_. C-. Il SLOPE SITE PLAN WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT DEPTH? Depth to Waler Aller ,.e, MonilorinD? ~'V(~_ Dale: Reading Date Gross Net Depth to Net Time Time Water Drop Lf' S' I& PERCOLATION RATE ,~r (minutes/inch) PERC HOLE DIAMETER COMMENTS PERFORMED BY: ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES INEFFECT ON TRIS DATE. 72-008 (Rev. 4/85) TEST RUN BETWEEN -~ e/.. FTAND ~/'~-~FT (~g~l.~.=~) ~-t-'~'~,/V'^'~Y I~-ATI ~ uv~¢-(~ 4~o~tro~ I)~ ~r~ CERTIFY THAT THIS TEST WAS PERFORMED IN Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 3 14 15 16 17 18 19 2O Township, Range, Section: SLOPE WAS GROUND WATER ENCOUNTERED? IF YES, AT WHAT I OL DEPTH? t l p Moniloting? ~ 0 Date; SITE PLAN Reading Date Gross Net Depth to Net 'rime Time Water Drop PERCOLATION RATE ~,' ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN ~" ~/ 'Z FT AND COMMENTS 1~/,3 J-~ ~ OK) ~L~L~/~JAg, ¢'L-/~ 'e P ERFORMEDB¥: I ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFF~/~T ON THIS DATE. 72-008 (Rev. 4/85) FT CERTIFY THAT THIS TEST WAS PERFORMED IN DATE: F''~g ~! l¢~[ Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O DATE PERFORMED Township, Range, Section: T I}/U ~:~cO <~ II SLOPE SITE PLAN ENCOUNTERED? S L IFYES, ATWHAT ,~?~- I~... pO DEPTH? E Depth to Water Alter Monitoring? gate: Gross Net Depth to Net Reading Date Time Time Water Drop %-, PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER __ TEST RUN BETWEEN --. FT AND FT COMMENTS ('/'~I~'-~L-'-~- /"¢'O¢'J¥~S'O~-'")t~" O¢'JN"'~l,~' '~'t'(~'"P'~Y~'/'""-"~O~L'"¢' ~lF' PERFORMED BY: ~['~ I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ,~¢ I -~tK)l-'~ DATE PERFORMED~::___ LEGAL DESCRIPTION: L ILA ~8 ~v~t~ Township, Range, Section: [ SLOPE SITE PLAN 5 6 7 8 9 10 11 12 13- 14- 15- 16 17 18 19 2O COMMENTS WAS GROUND WATER ENCOUNTERED? ~ S L IF YES, AT WHAT ~ O DEPTH? P E Depth tO Water Alter ~"/Z.F~/~ Monil0riflo? /,,J 0 r'.' ~. Date: Gross Net Depth to Net Reading Date Time Time Water Drop PERCOLATION RATE -- TEST RUN BETWEEN __ {minutes/inch) PERC HOLE DIAMETER FT AND FT PERFORMED BY: ('.,/~ L--- I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~/~'~'~ 72-008 (Rev. 4/85) MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anci~orage, Alaska 99519-6650 343-4744 Parcel 1, GENERAL INFORMATION Complete legal description!' 61~0.~h :~) ~ CERTIFICATE OF r-lEAL:TH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING gocatio? (s!te address or'di~ections) ~'~'~)'-~. . r~)~:iV~---' Pl;0perty oWner,~'~)l-/1' ~../,"~p-~--~'~,~l~\O-J('- Day phone,. Mailing a~d'r~::~~OqO ~gJ~+~" ~' ~q~ L:;nai'~g: a~:~H~y. ;;- : · Day'phone Mailing Address ' "' Agent · Day phone Address Unless otherwise reque,sted HAA will be held for picl~up. 2..'UM"E"'O "ED"00Ms:' ~ 3, TYPE OFWATER SUPPLY: Individual wel ~' Community well Public Water NOTE: If community well system, provide written confirmation from State 'ADEC attest- ~i'ng to the legality and Status of sYStem. 4. TYPE OFWASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 5. STATEMENT .OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date snown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply ano/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in corn pliance wi~h all Municipal and State codes, ordinances, and regulati0n~ in'~fe~t on the d~t(~'o~; this inspec~i0n.. Name of Firm ' /~/[///~ :'~///~ ?~ ~ ~/~ ' Phon~ -~): . ~/// DHHS 'SIGNATURE r?A/ Approved for /74 ' ' · bedrooms. Disapproved. Conditional approval for bedrooms, with the foli°Win[~'istipuiations: Additional Comments . By: Date The MUnicipality Of AnChorage Department o{'Heal:th and ' ~ ' Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5'above by an independent professional engineer registered in the State of Alaska, The DH HS does this as a courtesy to purchasers of homes and their lending institutions'in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Health Authority Approval Checklist Legal Description: ~ {i~"~otr~ V(i~/p-_~.5 .~(~p~] }5 Parcel I.D.: O~O' A. WELL DATA Log present (Y/N) Y Total depth F~' -~- ' Sanitary seal (Y/N) / If A, B, or C, attach ADEC letter. ADEC water system number Date completed Cased to / 7~ / Casing height (above ground) Wires properly protected (Y/N) Date of test Static water level Well production FROM WELL LOG AT INSPECTION g.p.m. WATER SAMPLE RESULTS: Coliform Date of sample: B. SEPTIC/HOLDING TANK DATA Dateinstalled ~// I / ~~] Foundation cleanout (Y/N) Nitrate ~, ~'~ ~ Other bacteria Collected by: Tank size /,~"~ ~ Number of Compartments ~ Cleanouts (Y/N). k/ Depression (Y/N) / High water alarm (Y/N) ? Date of Pumping "---- Pumper C. ABSORPTION FIELD DATA Date installed ~.//I/~ Length /¢~) / Width Effective absorption area. Soil ratin~r fF/bdrm) t Gravel thickness below pipe Monitoring Tube present (Y/N) Date of adequacy test Results (Pass/Fail) Fluid depth in absorption field before test (in.); _~ after Fluid depth j~'~s')d~'u t e~at e r: Peroxide treatment (past 12 months) (Y/N) ¢' System type ~Qe/~ 4/// Total depth ~ ~, / Depression over field (Y/N) /V' For ~ bedrooms gal. water added (in.): Absorption rate = g.p.d. If yes, give date 72-026 (Rev. 3/96)* D. LIFT STATION Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested ..~ Size in gallons "Pump on" level at* CY "Pump off" level at* *Datum z~bC/z¢'~ E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field on lot Public sewer main Sewer/septic service line On adjacent lots On adjacent lots Public sewer manhole/cleanout Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation /~/''/'' Property line /d/'/" Absorption field /d /'/- Water main/service line ~.- ,¢' ~' Surface water/drainage /,¢J /"/'- . Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ~ ~ Surface water /,¢,¢ /'''~ Curtain drain /~¢ /'¢' Building foundation /¢¢ /4- Water main/service line ~, 5" /,¢- Driveway, parking/vehicle storage area Wells on adjacent lots /~P ENGINEER'S CERTIFICATION I certify that lhave determined thru field inspections and review of Municipalrecords t__~(~ro-v~i~,~s are in conformance wi~h MOA HAA guidelines in effect on this date. ~,'~, ... ~ % ~ ~ HAA Fee $ Date of Payment Receipt Number ;SO0 Waiver Fee $ Date of Payment Receipt N umber ~ ~) I ~:~ ~/'C'~O'~ ~',~¢~ .,~ 72-026 (Rev. 3/96)* MUNICIPALITY OF ANCHORAGE Department of Health & Human Services On-Site Services Waiver Review Worksheet WR#: WR000009 PID#: 020-413-41 HA#: HA000055 Date Received: February 18, 2000 Legal Description: Paradise Valley Subdivision, Lot 12A, Block 8 Engineer: KND Engineering 20441 Ptarmigan Blvd,, Eagle River, AK 99577 Applicant; Bill & Helen Fowler Waiver Requested: 3 foot lot line waiver Permi¢: SW980439 Criteria: 1. Geology Points: A. Water Table B. Soil Sorption C, Permeability D. Water Table Gradient E. Horizontal Separation 2. Special Conditions: 3. Other: Total: Waiver is Granted: ~ List Conditions or Reasons for above: dY ¢ T/ ¢ T/OW' Waiver is not Granted: Date: Name of Reviewer Rec#: 5612 Amount: $115.00 Date Paid: February 23, 2000 ~<ND ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 February 18,2000 Municipality of Anchorage Dept. of Health & Human Services On-site Services Section P.O. Box 196650 Anchorage, AK 99519-6650 RE: SEWER PERMIT/LOT LINE WAIVER - PARADISE VALLEY S/D, BLOCK 8, LOT 12A Gentlemen: During the as-built process we encountered a problem with the system being in close proximity to the lot line. Subsequently, we had the system surveyed and verified that the system was constructed within 10 feet of the property line. Also to verify soils, an additional test hole was performed (TH 99-1) and another perc test was performed on TH 96-1 between 3 and 4 feet with a perc rate of 0.8 GPD per square foot (see attached). The system is still located within the original and the before mentioned additional test hole radii. We do not expect there to be any adverse effect on adjacent lots by the location of this system. We are therefore requesting a waiver to 3 feet to lot line at this time. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, KND Engineering K~enne~ P i Attachments: As-built Inspection Report HAA w/waters Well Log Additional Test Hole 99-1 Additional Perc TH 96-1 Pnm~3 Da~,'Tit'nu: 02-,,2~00 1 ? 00 Co~t Da~e.fT, im¢, 021100 Rec~.~ D~,tm/Tirr~: 0.~Z1/00 10;10 Tec~a! Director $[e~q Total COil~ N~:mte 0 53 O 5 m~ EPA 300 iO.O 02/21/C9 SCL