HomeMy WebLinkAboutGATEWAY TO THE PARK BLK 1 LT 8
Municipa tYof
Anchorage
POU .'{ 6-650
ANCHORAGE, ALASKA 99502-0650
(907) 264-4111
TONY KNOWLES.
MA YOR
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
Permit ~: 840740
January 31, 1985
TO: Permit Applicant
SUBJECT: Lot 8 Block 1 Gateway to the Park Subdivision
A permit issued by this Department for an individual well
and/or on-site sewer system has expired as of December 31,
1984.
Permits are issued on a calendar year basis by authority
of Municipal Ordinance. A new permit must be obtained from
this Department for any well and/or on-site sewer system not
installed by the expiration date.
If you have d~illed the well, a well log needs to be sent
to this Department for documentation of the installation
and to close the permit.
If a private engineer inspected the installation of the
on-site sewer system, the original as-built inspection report
and the yellow copy must be sent to this office for review
and approval, and for documentation.
If there are any further questionsf please call this office
at 264-4720.
Sincerely,
Keith E. Bandt, Sup( or
Environmental Engineering Program
KEB/ljw
enc: Copy of Permit
SWP/057
MUNIC ?AL ITY OF ANC ~ORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L STREET; ANCHORAGE, AK 99501
264-4720
ON--SITE SEWER ~, WELL PERMIT
PERMIT NO:
DATE ISSUED:
840740
08/31/84
APPLICANT:
ADDRESS:
CONTACT PHONE:
CREATIVE HOUSING INC
SR BOX 1612
EAGLE RIVER, AK] 99577
694-9239
LEGAL DESCRIP:
LOT SIZE:
MAX BEDROOMS:
SUBDIVISION: GATEWAY TO THE PARK
SECTION: 9 TOWNSHIP: 13N
.95A (SQ.FT. OR ACRES)
3
LOT: 8
RANGE: 1E
BLOCK: i
Listed below are the options available to you in designing your septic
system. Choose the option that best fits your site.
TRENCH BFD W. DR.'].II~I
DEPTH TO PIPE BOTTOM (FT.) 3.0 ** 4.0 4.0
GRAVEL DEPTH (FT.) 4.0 0.5 2.0
TOTAL DEPTH (FT.) 7.0 4.5 6.0
GRAVEL WIDTH (FT.) 2.5 19.0 5.0
GRAVEL LENGTH (FT.) 57.0 36.0 63.0
GRAVEL VOLUME (CU. YDS. ) 2.3.8 25.4 29.2
TANk-:] SIZE (GALS) 1,000.0 ** 1,('~00.0 ** 1,000.0 **
SOIL RATING (SQ..FT. /BR) 150 150 150
** DEPTH TO PIPE BOTTOM < 3.5 FT. REQUIRES INSULATION
** DEPTH TO PIPE BOTTOM < 4.0 FT. MAY REQ.UIRE A LIFT STATION
** TANK MUST HAVE AT LEAST.TWO COMPARTMENTS
I certify that:
1. I am familiar with the requirements for on-site sewers and wells as set
£orth by the Municipality of Anchorage (MOA) and the State of Alaska.
2. I will install the system in accordance with all MOA codes and regulations,
and in compliance with the design criteria of this permit.
3. I will adhere to all MOA and State of Alaska requirements for the set back
distances from any existing well, wastewater disposal system or public
sewerage system on this or any adjacent or nearby lot.
4. I understand that this permit is valid for a maximum of 3 bedrooms and
any enlargement will require an additional permit.
IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES,
THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (~) AS-BUILTS
WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REF'ORT; AND (3) THE
MUNIC ~ALITY OF ANC .ORABE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L STREET, ANCHORAGE, AK 99501
264-4720
ON--SITE SEWER & WELL PERMIT
PERMIT NO:
DATE ISSUED:
840740
08/31/84
APPLICANT:
ADDRESS:
CONTACT PHONE:
CREATIVE HOUSING INC
SR BOX 1612
EAGLE RIVER, AK 99577
694-9239
LEGAL DESCRIP:
LOT. SIZE:
MAX BEDROOMS:
SUBDIVISION: GATEWAY TO THE PARK
SECTION: 9 TOWNSHIP: 13N
.95A (SQ.FT. OR ACRES)
3
LOT: 8
RANGE: 1E
BLOCK:: 1
Listed below are the options available to you in designing your septic
system. Choose the option that best Fits your site.
BED /J W. DRA I N
DEPTH TO F'tPE BOTTOM (FT.) 4.0 ~'~'~'. 4,~....O
GRAVEL DEPTH (FT.) 0.5 / t~-~_ ~. 0
TOTAL DEPTH (FT.) 4.5/ ~~ ~ . _
GRAVEL WIDTH (FT.)
GRAVEL VOLUME (CU.YDS.)
TANK SIZE (GALS) 1~000.0
** TANK: MUST HAVE AT LEAST TWO COMPARTMENTS _~7
I certify that:
1. I am Familiar with the requirements For on-site sewers and wells as set
Forth by the Municipality oF Anchorage (MOA) and the State oF Alaska.
2. I will install the system in accordance with all MOA codes and regulations,
and in compliance with the design criteria o¢ this permit.
3. I will adhere to all MOA and State oF Alaska requirements ~or the set back
distances £rom any existing well, wastewater disposal system or public
sewerage system on this or any adjacent or nearby lot.
4. I understand that this permit is valid ~or a maximum o£ 3 bedrooms and
any enlargement will require an additional permit.
IF A LIFT STATION IS INSTALLED IN AN AREA COVERED BY MOA BUILDING CODES,
THEN (1) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS
WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE
ELECTRICAL WORK] MUST BE DONE BY A LICENSED ELECTRICIAN.
APPLICANT: CREATIVE HOUSING I~
ISSUED BY
2
~3
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG- PERCOLATION TEST
SLOPE
11
12
13-
ENCOUNTERED?
IF YES, AT WHAT
DEPTH?
.J~ SOILS LOG
[] PERCOLATION
TEST
SITE PLAN
14-
17
COMMENTS
PERFORMED
BY:
Gross Net Depth to Net
Reading Date Time Time Water Drop
/
PERCOLATION RATE
TEST RUN BETWEEN FT AND ~ FT