HomeMy WebLinkAboutGIRDWOOD ORIGINAL TOWNSITE BLK 2 LT 24GI*rdwood
Original
Townsite
Block 2
Lot 24
#075-152-49
�efnJ Dri�illc�, enc.
Well Lo
�Yarr1)?(�� Dt•i(lin,)art/7ur.,;+Stria
::r,.(::rni:.R(:5k.:(a;�):1_•;:a:04092007
-
0409;2.0_07
Drilling Started. _ _ _ ('omplctcd. _ _
City:6oruu_h:
Subdivision:
BLOCK
1 1.0
Property Ouncr Xamc & Address: Larry palubicki '
P.O. Box 583 Site. Old Girdwood
Girdwood
Original Townsite
2
24
_
_
Girdwood Ak.99587
Meridian Town+hip Ranee S=cion VA of ;•a of _ %a of % i
BOREHOLE DATA(from top of easing)Depth
Dnllin_= method. (X ) .Air rotary_( ) Cable tool, Other
Marcrial: Type, Color & %vujcss From To
I
Well use: ( ) Puhlie supply, IX ) Domestic. Other — - —
stickup
0
2
I Depth of hole: _$Q_ n, Casing stickup: 2_—n
Casing typc:steel .. 'Ihickness:__250inches
sand & gravel
2
8
Casing diameter. _ 6_ inches Caving depth: ,_80 •__ n
Liner type: - Diameter: _inches Depth: - t)
clay w/ gravel
$
10
Static water (from top of casing): 3'8_' R on04 ' 09.2007
Pumping level & yield: feet afier - hours at gpm
Rccovery rate: 50+ jrTm. hiethod urrestin_: airlift
sand & gravel w/ H2O
10
18
Dcscloprr.cm method: airlift Duration: 1 hour
wet silty clay
18
40
Well intake opening npc: (X) Open cnd. t ) Open hole. Other __
Screened. Start: - Ii. Stopped.__
gravel w/ H2O
40
52
Screen type: - Slot 'mLsh size: -
Perforated: Stan: n. Stopped: n
gravel w/ claylayers & H2O
52
56
start: - n. Stopped: - n
Note*
Grout type: b*rito�i= N,blumc _
gravel w/ H2O ,
56
65
Depth; from ground surface
dry silty clay w/ rocks
65
70
Pump intake depth: _ _ - fi
Pump size: hp. Brand name:
coarse gravel w/ H2O
70
80
Was well disinfected upon compictiotil (X) lbs. ( ) No
Method of disinrcction:Calcium.H pochlorte..(Chlorine)...
Driller conuttcnis disclairten:...............................................:............ '
............... _.................................................................... -.......
..........................................................
`Vkell driller name: Johnny Kay
Company name:...Hefty.Drillingr Inc:
........ ..........................
Mailing address:... 3.f`i'4...0 Akula Dr. ..............
ray: Anchorage_ stwc:.4K zip 99516
_
Phone number : ( 907 ) 345 _ 0593 fax:345-4700
Drillers si.naturc:
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Section
4700 South Bragaw St,
P.O. Box 196650 Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
zatention: Property�6wner shall provide a well log to the
)SD within 60 days of well completion.
Permit Number: SW070026
Dme of Issue:M�tL
ParclldentiticationVumber. /J —152-49
Is well lucated at upprt»cd pcnit lucatiun'.' (x) Yes or ( )No
Pump Installation Log
.� �cAnoY � b/ f a y �,� o IrT" 1
KAYE: r r C% j
"a< CR(XM DATE C9�i O
CASR+C
iPitless Adapter Manufacturer's Name: Ca ,1 1 a, ) 0 7(
Pitless Adapter Installer. A e , i O'
IO 91
PUMP rfPE u tC n ey6 !C
YAK[
A r r-k4j r
YODE1, T- 6 -50 .2 N.1rLRMV
&y Di-107'11gc inc
%ti�CI�61' lVect cilli-TLi;11�I Jf111Cc
(90) 345-0503
v
DROP TTPL Type Pyl.._ s:,.
I"
Condtion ! / e N,/
..
a POrkRCARtL• Tyq34riGY plK.L S+ta
)�l� N/CiY'al
SS Co Wcn
,I ELECTRICAL; vau 10
An" (a 0
' WATER TAM Ty"
WELL CASING S40 Diu. Tip
_
,
ICASED MCI-• Fran G.J To
STRUC1UR£: TW, r7 f'✓'r1 1"d
iINTAKE
, From " To
CM NOME: rran
well was disinfected upon completion.
method: calcium hypochlorite.
&y Di-107'11gc inc
%ti�CI�61' lVect cilli-TLi;11�I Jf111Cc
(90) 345-0503
v
�•� . � /V� S % Z•'�i �S WiL�V `YI Tl�� •� � � • y v -y �e�.. - ..
Aao SS R1-
i
Lor z(O
alt its a1
1 'SS:OpeE IZO.00
I
� . , . 1/. M••L.e.. rl ITtciLe '•� i116G
L'dUR.I µeye
O E/t5T1.Ka.C6hrh._ r..
20FLoLaL. T15-1 LOT ZS nye 'co ss
-
fit I
b„ 'i 111 O
/nT?
E IZo•oo N
h • _ yay.r jk%-j46 vi
Z :: O pa1J F C•ttftA6o •:j O N
Qlv
"&cOO-SS%OoeW 120-00
1 -
ZT.1 .!3}IST. f¢LlPVr 19.11.►JC�;, NorG:_ .ISasg fl,00p. GLeV. 241..__
PLOT PLAN AC 3UILT X SCALEla:•�o GRID 5112 JOB No `Jo -119
LltS1!!S t7LYi `-+d C L'_f !S'S 0 u George BellCircle
C Anchwale, Alaska 99515
' (907) 545-6476
I Hereby certify. that i Lata LZ0 oawgSdter
Slot 2 d•property:
Apjc Hoa.fbU Racwdiaq Disv::, Alaska, and that the lmp-ovamants sltaated thereon are
within the property Uses and do-aet aaooach onto the prapartT adjacent therato, that so
Improvements an the property lying aLjacaat thereto entr",j on the ,arta}ed pramicas and
that there art ne roadways, transmission lincs.r'etbar.visibt� aaumanv on said property
except as indicated heraen.,
Dated this the �eS>:y of • ' CQ 0. •1 I S ,�` a.. �4cbwa}a. Alaska
!'
It is the responsibiAty of t!a•eaiar ie detcrmiai the existent of any aastments, tovmants,
at ristr[ctims which da aet Aron thi racwdad mbditision plat.
CO
Ke Ih a tog • `•^
�•,• LS -5202 ` ss
It
0
4
========4
FMV
V CO
I
I
0
r
I I
I �
I r"
Z
g
CL
I 0
0
I 'i
LL
C)
Z
N
7 -hr, Qri J,rta) WGI1 Wie, CvLld n04-
bz�. door,
�GGcc»C oL over },1
�ot✓�� ).his The
13cbrn j��,5hf OC
-}ham
d7r�)I Tig iS
�r-I)e,r
lhen +hL Powc(
)than
l7ivrdi��
L-o�' �Ll,
('Lloc,4,8
we -l)
+o
da off'
e X j.54 -i' -n-3
wi
1z,79 --0K
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519.6650
(907) 343-7904
ON-SITE WATER SUPPLY PERMIT
Initial
Date Issued: Apr 02, 2007
Expiration Date: Apr 01, 2008
Permit Number: SW070026 Parcel ID: 075-152-49
Legal Description: GIRDWOOD ORIGINALTOWNSITE BLOCK 2 LOT 24
Design Engineer: 0000 ZZ - NONE NEEDED
Owner Name: LARRY PALUBICKI
Owner Address: PO BOX 583
GIRDWOOD . AK 99587 -
Site Address: 282 MAIN STREET
Lot Size: 3600 SQ. FT.
Total Bedrooms: 1 Permit Bedrooms: 1
This permit Is for the construction of:
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
-THE ORIGINAL WELL NEEDS TO BE PERMANENTLY DECOMMISSIONED PER AMC 15.55.060J,
DOCUMENTATION NEEDS TO BE SUBMITTED WITH NEW WELL LOG.
-THE INSTALLATION OF A WATER WELL SHALL MEET ALL THE ANCHORAGE MUNICIPAL CODE 15.55.
PLEASE SEE THE ATTACHED SHEET "PERMIT REQUIREMENTS FOR A DOMESTIC WATER SYSTEM'. IT IS
THE BURDEN OF THE PROPERTY OWNER TO DETERMINE THAT THE PROPOSED WELL WILL NOT HAVE
ANY ADVERSE IMPACTS ON ADJASCENT WELLS OR WASTEWATER SYSTEMS. IF THERE ARE ANY
QUESTIONS PLEASE CALL THE MUNICIPAL ON SITE WATER AND WASTEWATER PROGRAM AT
907-343-7904.
Received
Date: `ll314-7
Issued By. t (1 Date: r Z /^
Municipality of Anchorage
40.
Development Services DepartmentBuilding Safety DivisionOn-Site Water and Wastewater Program..
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.orglonsite
(907) 343-7904
ON-SITE SEPTIC/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. W-5+ 15:91- Ln
Property owner(s) La P' ( ;)r 1 Y—` Day phone 2r-3— 13 4 7 -
Mailing address p.0 t3o* S�3 (-, CC� L "Xrj tjZip Code
Site address4 � Zip Code 95 7
e1K0iW10L0 Legal description (Sub'd, Block & Lot) �a��
Legal description (Township, Section & Range) -Foy I i,s to e1S old
Lot Size x(70 Sq. Ft.
THIS APPLICATION IS FOR (®all that apply):
Absorption Field
❑
Septic Tank
❑
Holding Tank
❑
Privy
❑
Private Well
C9
Water Storage
❑
Number of Bedrooms
THIS APPLICATION IS AN:
Initial
11
Upgrade
1❑
Renewal
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
of property owner or authorized agent)
Permit/Rush Fees: S Waiver Fees:
Date of Payment: �5i_/�_'D 'r" Date of Payment:
Receipt Number. 9 a5ac� Receipt Number:
(Rev. 17105)
01
6r—t'uJe— • 1/.2o SS P -1--
i
I
LOT- zt-
r1.5
{ L'
i i '' SS, 00, I
Gltaa V N•Ha
FIe�xi%4.,nS
J •
+� -I �CSialiJL II
ib.a �1 IJoT 24
`�� f C-Maotso +i 31LGOs.�•
L.Wws"t s
ZIA :sp-x. OLeV,- OTT
ZotaEt_ 1?-rLI —
P—TOT PLAN __ AC BUILT X SCALEtj
1°• 30
M
,Vk%
fel -
/Q
4N6�
+M •
0 X
2!r
601
O
MVM'. EASS
O^^ �
0 0-
O V Q
CI I t
lea
GoL L
UDr-7.
GRID 5112_ 1013 No
1731 George Hell Circle
Anchorage, Alaska 99515 (907) 945-6176
I Eueby certify that i have s'.vtayed the following described property:
Lotz4x5.8loch?�_.-raw NSITE
Apir- a,F:vIF Reerding Oestri :, Aleska, and that the imp-oremtnts situated thereon art
within the property lines and depot encroach onto the propan.;- adjacent thereto, that nr
improvements on the property lying aijaeent thereto encroaet on the sunayed premises and
that there are no roadways, transmission limas or'ather Tisih easements on said property
azcapt as Indicated hsrton..
Datedthisthe SLDay of 7 r1IMS iR ; t Qbt.}nehoraoa, Alaska
�j
It it the r=nsibillty a[ the caner to Attermina the r=inaoea of any easements, eoaanants,
or ri strictians which dr not pear on thi recordad raodirfcion plat.
>� OF AQ7Tt
to
.. •/
Ls. 5202Ar
L �•p�leszlolTa\�MvJ/+
I,
ty A
o
a
-z—
�
ry^
`1
L.Wws"t s
ZIA :sp-x. OLeV,- OTT
ZotaEt_ 1?-rLI —
P—TOT PLAN __ AC BUILT X SCALEtj
1°• 30
M
,Vk%
fel -
/Q
4N6�
+M •
0 X
2!r
601
O
MVM'. EASS
O^^ �
0 0-
O V Q
CI I t
lea
GoL L
UDr-7.
GRID 5112_ 1013 No
1731 George Hell Circle
Anchorage, Alaska 99515 (907) 945-6176
I Eueby certify that i have s'.vtayed the following described property:
Lotz4x5.8loch?�_.-raw NSITE
Apir- a,F:vIF Reerding Oestri :, Aleska, and that the imp-oremtnts situated thereon art
within the property lines and depot encroach onto the propan.;- adjacent thereto, that nr
improvements on the property lying aijaeent thereto encroaet on the sunayed premises and
that there are no roadways, transmission limas or'ather Tisih easements on said property
azcapt as Indicated hsrton..
Datedthisthe SLDay of 7 r1IMS iR ; t Qbt.}nehoraoa, Alaska
�j
It it the r=nsibillty a[ the caner to Attermina the r=inaoea of any easements, eoaanants,
or ri strictians which dr not pear on thi recordad raodirfcion plat.
>� OF AQ7Tt
to
.. •/
Ls. 5202Ar
L �•p�leszlolTa\�MvJ/+
LoT' ?~'L
6o~ 3A
PLOT PLAN ~- AS BUILT __
SCALE
GRID.
1731 George Bell Circle
Aachora~t7 Alaska 99515
I lttr~b¥ certify that I hart surYty~d the following d~scribad property:
~FlOaq~t,~ Rtcordin~ Distric% Alaska, and that th~ improvtmtnts situated tharton art
within th~ property l/nt~ and do not tncroacb onto tbt proptrty ~djactnt thtrtt% that no
improvtmtnt/ on iht property lying adjactnt thereto tncroach on th¢ survtytd pr=mists and
that thtrt ar~ no roadway*~ tran;mis[ion lints or other visibl~ ~a~tmtnt~ on ~aid proptrty
txctpt a; indicattd htrton.
It i~ th~ r~pon~ibility of tht owntr to d[ttrmint th~ ex/~ttnct ot ~ny [as~mtntI, covtnants,
or rtstrictio~ which do not ~pptar on tht rtcordtd subdivi;ion plat.
JOB i'io go'il?
MUNICIPALITY OF ANCHORAGE
DE' RTMENT OF HEALTH AND HUMAN SER ES ..~ ~'
Environmental Health Division D ''~''~ /
825 "L" Street, Anchorage, Alaska 99502, Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Name ~ DJSTANCES
HP~P I ~
~A ~ II ;p ~ ~A ~ I~ar ~TO ~ ABSORPTION
Address~UI~I ~ TANK FIELD WELL
~ WELL
~,o.~,~, IP.,~" No- N°' °f Be~°°ms 7~t
7~3 - a3~ ~7o ~ 7 . LOT LINE fO '
LEGAL DESCRIPTION
Lot Block Subdivlsion~ ~/~O~O~ ......... ~/~ Z ~ ' ' t
~V ~ ~ ~ ~ ..... ~ ~ ....... '~ - FOUNDATION 7~
Township, Range, Section AS-BUILT OIAGRA~ (Show location of well septic system, property hnes,
driveway, water bodies, etc.)
TANKS % N
: ManuIactu~er Capac~W ~n ~aaons
Matedal ~o. o~ Compa~ments
t/
~ TRENCH ~ BED ~ W. DRAIN ~ OTHER//~ / '~ ~
Depth to p~pe bottom from Total depth from original grade
original grade FT FT~
//
Fill added above original grade Gravel depth beneath p~pe
FT~' FT ~ ~
FT FT!
Totalabsorp, ea ..... SQ FT Distance between lines Fl///-- --~ ~ / ~ ' ~'' ~ //L fl ~ ~__~ ~ . ~. I /
SOFT ~
~ PRIVATE ~ OTHERfldentiiv) / ~ ~
~assmcaUon (A,B,C) ~otal Depth ~
Installe~ Date InsJalled:
.
Scale: j ti ~ ~ t ENG NEER'S
I ~~ ~ ~ ce~ill thai this inspection WaS pedormed accordi,g tO ail ~- . ,H~ODOR~ F. ,~O~E
Municipal and Slate guidelines iff ellect ofl Ibis date: /~ / / 7 (.~ ~ ~'~' ~'Y~%o u~ .... - ~ou-z~ o
.... ' "
.ealth Depanmem ~pprovau ,
I'.'1 U N :~: C ;l: P A i... ]: ",'-" Y O F A N C !..I O R A
S7¢5 L Str'~.:.~,r.+:,t., Pu'u::hcn'a~o:.;,~, Alaska
t:~ N ..... S :!: T E [.! (:3 L. D ]: N ii:) 'i A N K F'
MUJqlCIPAL!T¥ OF- ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
,$EP 2 4.1987
RECEIVED
~u[top lec/~nic~] Services
14530 Echo Street ·
¢
U icipality of Anchorage
MEMORANDUM
DATE: 'August 6, 1987
TO: Mary Autor, Community Planning Department
FROM: Robert W. Robinson, Program Manager, On-site Services ~/~
Health and Human Services Department
SUBJECT: Old Girdwood Townsite
Dan Roth has asked me to respond to your inquiry of July 14 regarding
this department's position on further development in the Old Girdwood
Townsite area. The problem is really two-fold: one part is that of
future development, and the other is that of existing development.
Our file information clearly shows that this land is unsuitable for
on-site wastewater disposal due to poor soils and a high water table
which is also influenced by tidal variations. Considering that
situation, you will find that this department writes generally negative
comments on proposed plats and even zoning changes which we review.
Unfortunately, our comments seem to frequently be overlooked either by
staff or by the platting or zoning authorities. From our discussions
with AWWU, the extension of public sewer into this area is years away,
therefore it would be prudent to delay development until sewer is
available. We are unable to grant holding tank permits for new
construction since AMC 15.65 prohibits their use except for existing
situations or where public sewer will be available within one (1)
year. There is a pending ordinance amendment (awaiting Assembly action)
which would allow holding tanks to be installed, however, we are
reluctant to predict the outcome of the Assembly action.
We are aware that much of the current development has occurred without
benefit of land use permits, or even on-site permits from this office.
As is the general policy elsewhere, when an illegal system is identified,
we make every effort to work with the owner to bring the system into
compliance. Where a dwelling already exists, a holding tank may be
allowed provided other criteria are met. Since Zoning Enforcement is
now targeting this area for land use permits, we will continue to work
with owners to gain compliance.
Clearly then, unless a lot owner can meet the technical requirements
of our ordinance, no new on-site septic permits will be written in this
area. That in turn means that land use permits will not be granted. The
only exception to this will occur when the development is for a
commercial or business use. At this point, our jurisdiction ends and
the State of Alaska is responsible for the on-site permits. There is
no doubt that ADEC has, in the past, written permits for situations
where this department considered the land unsuitable for development.
Mary Autor
Community Planning Department
August 6, 1987
Page Two
Your second inquiry concerned the Old Girdwood Townsite Mall which is
currently experiencing difficulties with the on-site sewer system. In
this case, our department made negative comments on the plat review
process, citing the need for the applicant to show three sites for
on, site disposal. Obviously he was unable to do this, but the plat
was approved over our objection. Later we were able to have the ADEC
require a single replacement area for the system on a lot to
the south of the mall. Please note that legally ADEC cannot require
a replacement site for any development. When the problem first appeared,
our department sent a sanitarian and an engineer to investigate. We
still retain jurisdiction over the public facilities within the mall.
Based upon our recommendation, the septic tank was temporarily converted
to a holding tank until such time as the design engineer was able to
effect an acceptable repair of the system. We were recently informed
by the owner's representative that the entire disposal system has
since been upgraded and the system is now functional. We still do not
have the groundwater monitoring information that we requested, and we
are still concerned with the possible encroachment of the groundwater
into the system. We were recently advised by the owner's representative
that the,entire bed system has been removed and replaced. ADEC advised
this dat~ that their office did not issue the required permit for
this latest upgrade and that a citation would be issued immediately.
We and ADEC share the opinion that there is probably groundwater
encroachment, and unless further intensive testing proves to the
contrary, the septic system will have to be converted to a permanent
holding tank.
RWR/ljw