GLACIER VIEW HEIGHTS BLK A LT 2
Glacier View Heights Lot 2 Block A P -650A #050-501-10 Municipality of Anchorage On-Site Water and Wastewater Program •(907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181236 PID Number: 050-501-10 Dwelling: ® Single Family(SF) 0 Duplex(D) 0 Multiple (SF and/or D) Project: 0 New ® Upgrade Name: ABSORPTION FIELD - EXISTING David & Teresa Oldham Address 0 Deep Trench ® Shallow Trench 0 Bed ❑ Mound 23111 Eagle River Road, Eagle River, AK ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 -- GPD/SF — Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot -- Ft. -- Ft. GLACIER VIEW HEIGHTS A 2 Fill added above original grade Gravel length Township Range Section -- Ft. -- Ft. Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES -- Ft. Ft. To Septic I Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dlst.between trenches From Tank i Field Tank Line -- Ft2 -- Ft. '+ TANK ®Septic ❑S.T.E.P. 0 Holding 0 Other Well 100+ -- -- -- 25 Manufacturer Capacity Surface Water ! 400'+ -- __ _ ANCHORAGE TANK 1000 Gal. TMaterial Number of compartments Lot Line I 5'+ _ i __ _ STEEL 2 NA Foundation 10LIFT STATION '+ -- -- '- t Manufacturer Capacity Curtain Drain NA � -- NA -- ------ --- Gal. Remarks Existing septic tank and upper 2 Pump on level at Pump off level at High water alarm at trenches decommissioned per code & in. in. in. reconnected to existing system. Pump make and model Electrical inspections performed by PIPE MATERIAL House to tank D3034 Tank to D3034 Installer Northern Excavation drainfield Drainfield-- CO/MT D3034 Inspector ARCTERRA BENCH MARK (Assumed elevation) 100 ft Inspecctios 1"8/15/18 2nd 8/15/18 Location and description date 3rd 4th Bottom of Siding COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL .44:410,:%.‘16,01„.r Conditional Approval: Date f eN .. �� ;\.I'' 4 J ,may if.-.lb.: j r, f._._os, A„.t..4 ,_ 4 \ 1I AT 0 ' � ' 4111r � : 110 Approved Date �(1`(g IIIP' 11:1110` Inspection Report ST copy 3.doc AS-BUILT SYSTEM DETAILS/SITE PLAN Permit OSP181236 GLACIER VIEW HEIGHTS LOT 2 BLK A PID# 050-501-10 t A/ \+ ��k `' �o . \1- .43) A 49,,p ,s‘41/ "‘ iiitij.: V v�tiii C. t •• sF h J / s• PAVED C B DECOMMISSI• u, EXIST. S.T. & UP•I- 2TTACHES G' A. �� NEW 101' GAL S.T. �,,' }AOS g ., ."kV • 0 4Q ti O r S h"N v0� st &z4., 4 _zse, ._ 7� 9 t � ^ �7SO^ SCALE' 1' = 30' tx m A-C=32,0' 97.08 97.0 B-C=17.5' tc B A_D=15. 4D=36,5 FINAL GRADt - • 1 WASS s 2d tIoOOGAL : SEPTIC -1r ? TANK EXISTING FIELDS g 91.177 X91.00 _ - Mil - `‘ I I SCALE' NTS f /-Ar� -Q,t, PREPARED FOR' gCerE N Ar . } DAVID & TERESA OLDHAM ti �, / 23111 EAGLE RIVER RD. //,Alt N ¢� E * . / * EAGLE RIVER, AK 99577 44° N , i509-954-0352 11111,31111111111 �'fI1Not,i FIELD BOOKS cawwtEne p 1I��3.l1II \ 1 0 # - CE-11 44 # a°'INDA"N/A oRAlwa BMW z111211101011 �. •c�3�b�c� 'r SWING{ SLS "'MED' KMD `� 1�il,/. },,R' 8 1 , 3810 ,'./ AMU: SLS ° 7/25118 ---1..,— N�\w ,,, e £ \ OVA °/4oe SW0159 c(4, c `_� �cA°rte FlLE i0B"� 18169 'P/p AK B95'77'�e 4,0` "`� �� r'o MUNICIPALITY OF ANCHORAGE mens On-Site Water&Wastewater Program �p So, • r PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite rot* , i),.partmc,nt ;;C;(-)-R-r: E On-Site Wastewater Disposal System Permit Permit Number: OSP181236 Effective Date: 8/3/2018 Work Type: SepticTank Upgrade Expiration Date: 8/3/2019 Tax Code Number: 05050110000 Site Legal Address: GLACIER VIEW HEIGHTS BLK A LT 2 G:0159 Site Mailing Address: 23111 EAGLE RIVER RD, Eagle River Owner: OLDHAM DAVID & TERESA Lot Size in Sq Ft: 29940 Design Engineer: ARC TERRA CONSULTING INC Total Bedrooms: 3 This permit is for the construction of: ❑ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska • Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: At time of construction, confirm tank is outside the soil bearing prism of the foundation (to be demonstrated on profile drawing submitted with inspection report) or relocate it at least 10 feet from the foundation. Received By: / Date: $ FireIssued By: ��I�" / ' Date: MUNICIPALITY OF ANCHORAGE . ' ( i• Community Development Department `\ yr" Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 050-501-10 Property owner(s) DAVID & TERESA OLDHAM Day phone 509-954-0352 Mailing address 23111 EAGLE RIVER ROAD, EAGLE RIVER, AK 99577 Site address 23111 EAGLE RIVER ROAD, EAGLE RIVER, AK 99577 Legal description (Sub'd., Block & Lot) GLACIER VIEW HTS. BLOCK A, LOT 2 Legal description (Township, Range & Section) Lot Size 29,940 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) x Absorption Field Initial Single Family (SF) (w/wo ADU) Septic Tank ) Upgrade Duplex (D) Holding Tank ❑ Renewal I Multiple Dwellings Privy (SF and/or D) Private Well Water Storage LJ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signatur roperty owner or authorized agent) rmit/Rush Fees: Qi s Waiver Fees: Date of Payment: 1-3 I- Date of Payment: Receipt Number: 113D Receipt Number: Permit No. (6 e 1 8' 123c Waiver No. Permit App_9-1-12.doc QRcTER,„ �¢ m ARC 1 IRRA • CONSULTING, INC 212 E. 50 Ave, Anchorage,AK. 99503 `*bf Nom. X41 Office(907)868-3791, Fax(907)868-3793 '9F `4A.TI NO..,0 •AK.WSTI July 27, 2018 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Septic Tank Upgrade Permit—Glacier View Hts. Block A, Lot 2 The owner has requested we proceed forward to obtain a septic permit to upgrade the aged septic tank on the subject lot. The proposed upgrade will serve the existing 3-bedroom house. The existing tank's location is approximately 7' from foundation with no known issues to the foundation. Due to elevations and tight location to wells, it is proposed to install new septic tank in same location. The tank will be placed as far as possible from foundation accordingly. The adjacent lots are served by private water as noted on the design. There is no surface water within 100' of the proposed tank. We do not expect there to be any adverse effect on adjacent lots by the development of this tank. If you have any questions, please contact me at 868-3792/FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. Kenneth M. Duffus, . Attachments: On-Site Sewer Application Wastewater Absorption System Details/Site Plan 20441 PTARMIGAN BLVD • EAGLE RIVER,AK 99577-8736 • PH(907)868-3791 • FAX(907)868-3793 WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLAN GLACIER VIE , HEIGHTS L❑ 2 BLK .7 1137..1. • ♦-4-I ' Mr, 4,' .. .r r N $ 414W4 ' e's co to N O a Y \ \ \ O m FLAG PROPERTY LINES WELL RADII & EASEMENTS Scaler 1'= 100' PAGE 1 OF 2 y PRI❑R TO CONSTRUCTION MAINTAIN 7'+ TO FOUNDATION .o & 5'+ TO ANY DECK SUPPORTS NO PUBLIC YELLS WITHIN 200' OF Z PROPOSED SYSTEM. 0 NO PRIVATE WELLS WITHIN 200' OF PROPOSED SYSTEM EXCEPT AS NOTED. DESIGN DETAILS > NO SEPTIC SYSTEMS WITHIN 200' OF m PROPOSED YELL EXCEPT AS NOTED. 1. INSTALL NEW 1000 GAL & INSULATE TANK IF <4' COVER. tz 2. CONTRACTOR WILL ENSURE MINIMUM 27. SLOPE INTO SEPTIC TANK. I 3. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT WELLS, SEPTICS EASEMENTS, PROPERTY LINES, ETC... OF 4\\ d / cS� •`S 1 PREPARED FOR: RCTERD 3 r(S� DAVID & TERESA OLDHAM 1, A "1'6,4,o / ��� '7 t23111 EAGLE RIVER RD. ° * •L� TH /' . * EAGLE RIVER, AK 99577 l$� iii / / 509-954-0352 i o s;(' t / FQ • IJElli S FIELD BOOKS COMPUTED: Es to , CF,' 4: / BOUNDARY:N/A DRAM: BMW Z 1 1 i' • ti$� STA1GNG SLS CHEO(EO: KMDco . U 1 07 ASBUILT: SLS DAZE: 7/25/18 �� •..r►�9c. \ 064 E \ SS D FILE: GRID: SWO159 C's C'o�,� 1l4 6^, \`\� ACAD FILE`FILE ""O•: 18169 SFR, AK.99577—`"5 6 WASTEWATER DISP❑SAL SYSTEM DETAILS GLACIER VIEW HEIGHTS LOT 2 BLK A vv / "ec' zi v }° \ \ I 6 , P//,� aril h + c).k. by o •A) \\ N.', AN Tti AlW � ® � tioc ilkC, 1/4./(/ ° ` es• s �o 15, a? A }a? f cxs• / PAVED * , D/W } G }/ REMOVE & RECOMMISSION . Cr �}./ V1 EXISTING S.,. & INSTALL ?G ,(�, �� NEW 1000 AL S.T. IN cp � 5 SAME LOC TION W/ e. POST-TA COs. A-eo } a / '\��. g • .4 co 6\6, SQ A3 j) O� N (0 52.6,,, 4 15 AD Y , 7/9 co �; • *43 a (ASO .4I SCJ U J Scale: 1'= 30' cis MAINTAIN 7'+ TO F❑UNDATI❑N PAGE 2 OF 2 & 5'+ TO ANY DECK SUPPORTS FLAG PROPERTY LINES `I` WELL RADII & EASEMENTS U .. **:•:111k‘ PRIOR TO CONSTRUCTION Li / �ANP-� OF <Q 1 PREPARED FOR! RCTE.R it. �� '1 1 DAVID & TERESA OLDHAM ti "� �, rn ,-1 ��i 23111 EAGLE RIVER RD. ��� s�, ° /* . 9 Til fN * T. EAGLE RIVER, AK 99577 ° (((i1 �, .i .. 509-954-0352 i..7. , • M S FIELD BOOKS COMPUTED:lik (,'$ 'rbrBOUNDARY:N/A DRAWN: BMW ZR. '"tn •Q .ti$ sKING: SLS CNECKED: KMD j �^a 1 SVg7 o�� ASBUILT: SLS DATE. 7�25�18 ', yc \ �0�aO1i \ S DWG. FILE: CRID: C C' �� G 11 ES W0159 's OA,S l� 06 Z '1•116:16:11110:411°- ACRD FILE:FILE JOB No.: 18169 A .AK 99571"-- 1' t ns ..pcs,.:w�" 1 rm- 4.^�� _. 1 'Old 4it I h) January 10, 1986 TO: Permit Applicant I a6,^0-50 ^_ ANi HORAGE ALASKA 99-02-0850 (907}264-4111 -C N' KNO VILE S. y!4 DEPARTMENT OF HEALTH & HUMAN SERVICES Subject: Permit # 850397 Let -3- Glaci,r View Heights Subdivision A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1985. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system the original as -built inspection report(three part form) must be sent to this office for review and approval,and for documentation. If there are any further questions, please call this office at 264-4720. Sincerely, Susan E. Oswalt Program Manager On-site Services SEO/ljw enc: Copy of Permit C! � ' I C -D, .1 K=P �X -T c) F= eA P%J C-� FZ e7�k U� F�� DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L STREET, ANCHORAGE, AK99501 264-4720 PERMIT NO: 850397 DATE ISSUED: 07/08/85 . ` ~ APPLICANT: ADEPT CONST ADDRESS: SR 177 PREUSS EAGLE RIVER, AK 99577 K A LEGAL DESCRIP: SUBDIVISION.- GLACIER VIEW HTS LOT: 2 BLOCK: - TOWNSHIP 14N RANGE: 1W SECTION. -,16 : LOT SIZE: 78856 (SQ.FT. OR ACRES) I -certify that: I �� ili with the requirements for on-site sewers andwells as set J' am am ar ^ ^ forth -L�e �unicipality�o� Anchorage (MOA) and the State o� Alaska" �or y rn ' 2°-I w���l-install ��the ' system � in accordance with all MOA codes and regulations, and in compliance with the design criteria or this permit. ^ �`- ll MOA d State o� Alaska requirements for the set., back 3 I will. ^ -~�-- dista l, wastewater disposal system or public adjacent. or nearby lot. sewerage any DATE: SIGNED _ ' DATE: ISSUED BY \ � • • PGE 8, •, s r Municipality of Anchorage 0 On-Site Water and Wastewater Program ;;Lil (907) 343-7904 SA ETY CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 050-501-10 Expiration Date: f Y - IEe-6 1. GENERAL INFORMATION Complete legal description GLACIER VIEW HEIGHTS BLOCK A, LOT 2 Location (site address) 23111 EAGLE RIVER ROAD,EAGLE RIVER,AK 99577 Current Property owner(s) DAVID &TERESA OLDHAM Day phone Mailing address 23111 EAGLE RIVER ROAD, EAGLE RIVER,AK 99577 Real Estate Agent Day phone 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class_Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ SzC- 5. 0 Waiver Fee $ Date of Payment 27l I ('/ .1 ? Date of Payment • Receipt Number a G q s 3p Receipt Number COSA# (9C C } ! 41 co' Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING,INC. Phone 868-3791 Address 20441 PTARMIGAN BLVD.,EAGLE RIVER,AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 8/15/2018 Engineer's Comments:This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested.The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface,changes inland use,local soil characteristics,groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future ��\ occupants or can ArcTerra guarantee that no unseen ` OF ALS encroachments,deficiencies or discrepancies exist. cS�i X16 (Sr 49 .ft * j 6. DSD SIGNATURE . System #1 Approved for . bedrooms. 4 �� KENN �. 11V 7116 F / yATF' / � System#2 Approved for bedrooms. �;o /b i}G.r Pfio .ss or' - r Disapproved. Conditional approval for bedrooms, with the following stipulations: iv SITE `-'e 1 ' IFR AND c' 11, ,TEWATER e A, I ;RAM c • By: Original Certificate Date: ( 7-1Q The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other • COSA blue sheet 10-10-12.doc If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: GLACIER VIEW HEIGHTS BLOCK A, LOT 2 Parcel ID: 050-501.10 A. WELL DATA Well type PRVT If A, B, or C provide PWSID#_ Well Log(Y/N) Y Date completed 411985 Sanitary seal (Y/N)Y Wires properly protected (Y/N)Y Total depth 87 ft. Cased to 87 ft. Casing height(above ground) 24+ in. FROM WELL LOG AT INSPECTION Date of test 4/1985 7/312018 Static water level 67 ft. 61 ft. Well production 5 g.p.m. 4+ g.p.m. WATER SAMPLE RESULTS: Coliform NEG colonies/100 mL Nitrate 0.189 mg/L Arsenic: ND ug/L Date of sample: 713/2018 Collected by: ARCTERRA B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC I STEEL Date installed 8115/2018 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N)Y Foundation cleanout (Y/N) Y Depression over tank(YIN) N High water alarm (Y/N) N Date of pumping NA-NEW TANK Pumper C. ABSORPTION FIELD DATA Date installed 6/2211985 Soil rating (g.p.d./ft2 or ft2/bdrm) 150 System type SHALLOW TRENCH Length "118 ft. Width 5 ft. Gravel below pipe 2.5 ft. Total depth 6.5+ft. Eff. absorption area "687 ft2 Monitoring tube Y Depression over field N Date of adequacy test 7/3/2018 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 0 in. Water added 450 gal. New depth 6 in. Elapsed Time: 30 min. Final fluid depth 0 in. Absorption rate >=450+ g.p.d. Any rejuvenation treatment(past 12 mo.) (Y/N &type) N If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at_in. "Pump off"level at_in. High water alarm level at in. Datum Cycles tested _ Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot *961+ On adjacent lots 1001+ Public sewer main 75'+ Public sewer manhole/cleanout 1001+ Sewer/septic service line 25'+ Holding tank 100'+ Animal containment areas 50'+ Manure/animal excrete storage areas 1001+ SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 101+ Water service line 10'+ Surface water 1001+ Wells on adjacent lots 1001+ ABSORPTION FIELD ON LOT TO: Property line *5'+ Building foundation *51+ Water main 10'+ Water Service line 10'+ Surface water 1001+ Driveway, parkingNehicle storage 0' Curtain drain 50'+(NONE KNOWN) Wells on adjacent lots k961 F. COMMENTS *Multiple MOA waivers previously issued. *"Upper 2 trenches abandoned with septic tank upgrade. G. ENGINEER'S CERTIFICATION I certify that 1 have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. OF AL<,,ksl Engineer's Printed Name KENNETH M.DUFFUS / P� �. Date 8115/2018 �4• TH ,;* COSA canary sheet 2 6-15.doc AIWA A #, KENNETH M. / 16 ry r�9Eo a/I.b Na• PPFESSLOIIP .I I LOT 12 N56'09 27 W 148.46' (N56°10'00"W 150.06' REC) 0- -- 10' UTILITY ESMT �x—x—x—x—x—x—x—x—x—x— ‘ lc x \ x \�� r-X—X—X— rr IXLOT 2 \4. I BLOCK A -1- I x 7.0' I x N DECK o 2, I x x I-1012.0' DECK 61.0' 32.4' I j 12.0' E. EXISTING x o RAMP _ HOUSE cq LU �ri i w ' N O 38.5' 33.7' CA l� x y DECK • ICI0 reri x = 0)) ._1 0 _I X_— X DECK • •••• I '- HX M 0 22.5' 11111 O w ~STC ISM VE W (typ) to :`) i() PAVED Z Lo t+') DEW 1 • Z M ..� ;') ®WELL i, LC) to -- z z .• • S O p S54'26'45"E 149.74' (150.00' REC) (I) w a > EAGLE RIVER ROAD _ — ANCHORAGE RECORDING DISTRICT,ALASKA AS-BUILT OF: GLACIER VIEW HEIGHTS O• =FND 5/8"REBAR W/YPC LOT 2 BLOCK A PLAT P 650-A _`"X SURVEY CERTIFICATE:I,John L.Schuller,Have conducted a ...:f OF �Q��l 'UQ , LAND S DRl,4 physical survey of this property as shown on this drawing and that the / `S. '' `Qs11 4.�ti0 Sr,, , improvements situated hereon are within the property lines and no ��c� `) '1 ,�w� ''''?k.��� enchroachments exist other than noted.Under no circumstance should . 4.9TH i\ ', „ any information on this drawing be used for construction of fences, I-, structures,improvements,or for establishing boundary lines. / / i / x+a / IY / �• ,,gin EXCLUSION NOTES:It is the owners responsibility to determine p til �,co ....JOHN L. SCHULLER.: / A. ' .� the existence of any easements,covenants,or restrictions which ,0. do not appear on the recorded subdivision plat. ,'s�, LS-10408 ;� %....,.....‘...„,..--183 e� o . I' 1831 Talkeetna Street WORK ORDER NUMBER: DAZE SCALE: E-NAI: P V.,lin '•(P• cJ 1` o .., i1 A Anchorage, Alaska 99508 'AUGN16, 2018 615 1K��AD� VA ..Q. AirAEI (907) 227-1455 office 18-048-2 JLS SW0159 180214 �\ (907) 274-4992 fax • Municipality of Anchorage *A1 On-Site Water and Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL (t _T5$ve Parcel I.D. 050-501-10 Expiration Date:/ 0 -, 2 7 - /-6' 1. GENERAL INFORMATION Complete legal description GLACIER VIEW HEIGHTS BLOCK A, LOT 2 Location (site address) 23111 EAGLE RIVER ROAD EAGLE RIVER, AK 99577 Current Property owner(s) GORDON R. CAUGHMAN Day phone Mailing address Real Estate Agent 23111 EAGLE RIVER ROAD EAGLE RIVER AK 99577 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank' ❑ Community Class _ Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: COSA to be released to the engineer, unless COSA Fee Date of Payment Receipt Number COSA# 15- )1 g � Date: 7 cP%- /5 Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3791 Address 20441 PTARMIGAN BLVD., EAGLE RIVER AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 4/20/2015 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen OF AL\X , encroachments, deficiencies or discrepancies exist. All ti , A , ~/ A TTI 6. DSD SIGNATURE t/ System #1 Approved for 3 System #2 Approved for Disapproved. Conditional approval for bedrooms. bedrooms. i'y¢ KENNEIH M. u'.',�� ,r �P 7116ss..�i 1 o '7 4 is4eAlr F'Es510 p1' bedrooms, with the following stipulatipns:t;t ir1 o�S,::V OFANr WATER By: J Original Certificate Date: % s r The uni ' ch�t4 orage Development Services Division (DSD). issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet 1040-12.dw SGS SGS Ref.# 1153661001 Client Name AreTerm Engineering and Surveying Project Name/# Glacier View His Blk A Lot 2 Client Sample ID Glacier View His Blk A Lot 2 Matrix Drinking Water Printed Date/Time Collected Date/75me Received Date/Time Technical Director 07/23/2015 14:14 07/15/2015 10:00 07/15/2015 11:07 Stephen C. Ede Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date hat Waters Department Total Nitrate(Nitrite-N ND 0.100 mg/L SM21 450ONO3-F B (<10) 07/20/15 NLL Microbiology Laboratory E. Coli Negative 1 100mL SM21 9223B A 07/15/15 SLC Total Coliform Negative 1 100mL SM21 9223B A 07/15/15 SLC • Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 050-501-10 1. GENERAL INFORMATION MN 3retcherl' wailer Expiration Date: Complete legal description GLACIER VIEW HEIGHTS BLOCK A, LOT 2 Location (site address) 23111 EAGLE RIVER ROAD EAGLE RIVER AK 99577 Current Property owner(s) GORDON R. CAUGHMAN Day phone Mailing address Real Estate Agent 23111 EAGLE RIVER ROAD EAGLE RIVER, AK 99577 2. TYPE OF DWELLING: ® Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) Day phone 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ® Individual Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: COSA.to be released to the engineer, unless COSA Fee $ 5261 —t Date of Payment Receipt Number Qot((el�9 COSA# Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on -procedures outlined in the Certificate -of -On -Bite Systems -Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3791 Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date 4/20/2015 Engineer's Comments: This investigation was completed in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, - ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen i , OF AL\ \ encroachments, deficiencies or discrepancies exist./ c4 , Air 6. DSD SIGNATURE _A/ System #1 Approved for-3—bedrooms. System #2 Approved for bedrooms. Disapproved. KE:v1ZETH 316 d F'F ` A� lype, D G' r�aEsstoN�' .� Conditional approval for bedrooms, with the following stipulations: By: Original Certificate Date: The nicip it ge Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other coshbl sshesr_1a10-12.dw If more than 1 septic system is on the lot: COSA Checklist # _of _ Structure served by this system _ Certificate of On -Site Systems Approval Checklist Legal Description: GLACIER VIEW HEIGHTS BLOCK A LOT 2 Parcel ID: 050.501.10 A. WELL DATA Well type PRVT Date completed 4/1985 Total depth 87 ft. Date of test Static water level Well production If A, B, or C provide PWSID # _ Sanitary seal (Y/N) Y Cased to 87 ft. FROM WELL LOG 4/1985 H# WATER SAMPLE RESULTS: ColiformAk_&- colonies/100 mL Nitrate ND mg/L Arsenic: ND ug/L Date of sample: 4/1512015 B. SEPTIC/HOLDING TANK DATA Well Log (Y/N) Wires properly protected (Y/N) Y Casing height (above ground) 24+ in. AT INSPECTION 411512015 ft. Collected by: ARCTERRA Tank Type/Material SEPTIC 1 STEEL Date installed 6/22/1985 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (YIN) N Date of pumping 4/812015 Pumper SANITARY C. ABSORPTION FIELD DATA Date installed 6/2211985 Soil rating (g.p.d./ft2 or ft2/bdrm) 150 System type SHALLOW TRENCH Length 116 (TOTAL) ft. Width 5 ft. Gravel below pipe 2.5 ft. Total depth 6.5.9.5* ft. (Measured 4115115) Eff. absorption area 906 ft2 Monitoring tube Y Depression over field N Date of adequacy test 4115/2015 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 0 in. Water added 460 gal. New depth 412 in. Elapsed Time: 10 min. Final fluid depth 0 in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed "Pump on" level at _ in. Datum Size in gallons "Pump off' level at —in. Cycles tested E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot *96'+ Absorption field on lot *961+ Public sewer main 751+ Sewer /septic service line 254 Animal containment areas 504 SEPTIC/HOLDING TANK ON LOT TO: Manhole/Access (Y/N) High water alarm level Meets alarm & circuit requirements? On adjacent lots 1001+ On adjacent lots 1001+ Public sewer manhole/cleanout 100'+ Holding tank 100'+ Manurelanimal excrete storage areas 1004 Building foundation 5'+ Property line 5'+ Absorption field 54 Water main 10'+ Water service line 101+ Surface water 1001+ Wells on adjacent lots 1001+ ABSORPTION FIELD ON LOT TO: Property line *54 Building foundation *5'+ Water main 104 Water Service line 101+ Surface water 100'+ Driveway, parking/vehicle storage 0' Curtain drain 50'+(NONEKNOWN) Wells on adjacent lots *96' F. COMMENTS As with the 2000 HAA - the top trenches are saturated and only the bottom 2 trenches were tested. *Multiple MOA waivers previously G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name KENNETH M. DUFFUS Date 4/20/2015 COSA canary sheet_2-6-15.doc ����, OF AL4, ,Af,�f * 471 Cm Y A KFNNEETVV—N7fU FA. Af 1[le �GAgr kSSiO��Aw 4 MUNICIPALITY OF ANCHORAGE • '- DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 (907)343.4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILLY DWELLING / Parcel l.D.# 050-501-10 HAA #t Property owner WYNN RACKHOUSE Day phone(907) —6429 Mailing address 23111 EAGLE RIVER ROAD EAGLE RIVER AK Lending agency Day phone Mailing address Agent BARBARA CRITTENDEN w/ PRUDENTIAL' Day phone X907) 973-5499 Address 16635 CENTEEDELD DRIVE EAGLE RIVER AK 99577 Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS: 3 3. TYPE OF WATER SUPPLY: Individual well xxx Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing, to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding Tank Community on-site Public sewer XXX NOTE: if community wastewater system, provide written confirmation from State ADEC ing to the legality and status of system. 72-025 (Rev. 1/91) Front MOA #21 Computer version Note: Alaska Water and Wastewater Consultants, Inc. shall be paid $2,570.00 at, or prior to, closing for the engineering services provided. 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is In compliance with all Municipal d State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm: Phone (907)_337-(3179 Engineer's Signature Date In conducting this evaluation, AWWC, Inc, atH m ed to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and M A Guldelfnes & Regulations. The reported results described the performance of the system under the conditis encountered at the time of the test and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local solls condition, ground water levels that may fluctuate during the year, and the water o�o�OO usage of the family being served by the system. These conditions are outside the control of o� F the evaluator of the system. Satisfactory test results do not guarantee future performance o 9 4 v.•• of the system, nor do they guarantee that there are no hidden defects or encroachments. p AWWC, Inc, can therefore not provide any warranty for future estimate of how long the •,y' system will continue to meet the operational requirements of the ADEC or MOA DHHS. „ . . . ...... ....... The content of this report Is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. DO of y A. c ness,r 6. DHHS SIGNATURE 4°p CE -7953 c°G Approved for .3 bedrooms 4�4p�aa".••no\�o°o o(essio .G Disapproved �0000G�o Conditional approval for bedrooms, with the following stipulations:, Additional Comments Z Date —Z 8 _00 — The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate Is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Baok M0A #21 Computer Version II%C;VCIVr.0 SEP 0 12000 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SWj�rpW§yOFANCHORA Environmental Services Division ENVIRONMENTAL SERVICES DI 825 "L" Street, Rm 502 Anchorage, Alaska 99501 (907) 3434744 Health Authority Approval Checklist Legal Description: GLACIER VIEW HTS. S/D; LOT 2, BLOCK A Parcell.D.: 051-501-10 A. WELL DATA Well Type PRIVATE If A, B, or C, attach ADEC letter. ADEC water system number N/A Log present (Y/N) YES Date completed 4/85 Total depth 87' Cased to 87' Casing height (above ground) 18"+ Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES FROM WELL LOG Date of test 4/85 Static water level Well production 5.0 g.p.m. WATER SAMPLE RESULTS: AT INSPECTION 5/26/2000 61.5' Coliform 0 Nitrate 0.500 mg/L Other bacteria 0 Date of sample: 8/1/2000 Collected by: A.W.W.C., INC. B. SEPTIC/HOLDING TANK DATA Date installed 6/22/85 Tank size 1000 Number of Compartments 2 Cleanouts (Y/N) YES NO High water alarm /N N/A Foundation cleanout (Y/N) YES Depression (Y/N) g (Y ) Date of Pumping 4-24-60 Pumper Ti S C. ABSORPTION FIELD DATA Date installed 6/22/85 Soil rating (g.p.d./ft2 or bd ) 150 System type TRENCHES Length 116' TOTAL Width Gravel thickness below pipe 2.5' Total depth 6.5' — 10' Effective absorption area 906 SQ FT Monitoring Tube present (Y/N) YES Depression over field (Y/N) NO Date of adequacy test 5/26/2000 Results (Pass/Fail) PASS For 3 Bedrooms *SEE ATTACHED LETTER FOR ADEQUACY DATA. Fluid depth in absorption field before test (in.); * Immediately after * gal. water added (in.): Fluid depth * (ins) Minutes later: Absorption rate = Peroxide treatment (past 12 months) (Y/N) NONE KNOWN If yes, give date 72-026 (Rev. 3/96r Computer Version D. LIFT STATION Date installed Manhole/Access (Y/N) High water alarm level ested –Z! E. SEPARATION DISTANCES Size level at* "Pump off' level at* *Datum SEPARATION DISTANCES FROM WELL ON LOT TO: *SEE ATTACHED LETTER. Septic/holding tank on lot *96'+ On adjacent lots 100'+ Absorption field on lot *96'+ On adjacent lots 100'+ Public sewer main Public sewer manhole/cleanout Sewer/septic service line 25'+ Lift station N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation 5' Property line 5'+ Absorption field — 5'4- '+Water Watermain/service line 10'+ Surface water/drainage 100'+ Wells on adjacent lots 100,+_ SEPARATION DISTANCES FROM ABSORPTION FIELD ON LOT TO: *SEE ATTACHED LETTER. Property line *5•+ Building foundation *5'+ Water main/service line._ -10'-1— Surface water 100'+ Driveway, parking/vehicle storage area --_0 Curtain drain F. ENGINEER'S ( I certify the of Munici al rel with MO HAA Signature Engineer's field inspections and review systems are in conformance wrthis date. JEFFREY A. GARNESS d -D-' HAA Fee r Date of Payment Receipt Number 72-028 (Rev. 3/98)" Computer Verslon Wells on adjacent lots Waiver Fee $ *96' OF A WIZINv MM A. Ga�ress� E-7953 ....... ... F,cAoF' `o f es sio��o� Date of Payment l Receipt Number ! lP we(:)V00 LPA Municipality ®f Anchorage Department of Health and Human Services�r 825 " U' Street Ride Mystrom. P.O. Box 196650 Anchorage, Alaska 99519-6650 Mayor http://www.ci.anchorage.ak.us October 6, 2000 Jeffrey Garness Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road, Suite 2-13 Anchorage, AK 99504 Subject: Waiver Request for Glacier View Heights, Lot 2, Block A P -650A Waiver Request #WR000067 Parcel ID 9050-501-10 HA000424 Dear Mr. Gamess: Your request for a waiver of the required 100 feet horizontal separation from the on-site wastewater disposal system to private well has been approved. The approved separation distance is 96.0 feet. Your request for a waiver of the required 10 feet horizontal separation from the on-site wastewater disposal system to property line has been approved for 5 feet. This waiver approval applies to the existing on-site wastewater disposal system to property line and private well separation only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, b�� ) I?V-q Daniel J. Roth Civil Engineer On -Site Water Quality Program MUNICIPALITY OF ANCHORAGE Department of Health & Human Services On -Site Services Waiver Review Worksheet WR#: WR000067 PID#: 050-501-10 HA#: HA000424 Permit#: Date Received: September 1, 2000 Legal Description: Glacier View Heights Lot 2, Block A P -650A Engineer: Alaska Water & Wastewater Consultants, Inc. 6901 Debarr Road Suite 2-13Anchorage, AK 99504 Applicant: Wynne Backhouse Waiver Requested: 96 foot separation distance waiver between well and septic system on the subject property S FEST raTHE S S . prevva,ary LI -v Criteria: 1. Geology Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation Total: 2. Special Conditions: 3. Other: Waiver is Granted: Waiver is not Granted., List Conditions or Reasons for above: SEE AVACNEO Date: J-2 7-00 By : )W Name of Reviewer ********** Rec#: 06165 Amount: $920.00 Date Paid: 9/1/00 u,IglvER al QUEST FOR LoT AG/Ele VIEW ybn. WR/veg REi7tair NuMBiR iv)g000067 ow L oT / ,FILA' X W141i/EI2 REevc*sr FoR 18ro evow f16L0 To l✓A7-tR#vvi-r-4oF n FveT. -SElaTK por-9- TKK S6prfc sysrr,wl itmo To se .4i0/MIlkNlrr 9Yrr;m wHE.V oxj6.iIvaj,1.i CONsrat-erro IN /[/$f; r/!F #sfovario,, op 6 fTEpPEI% rP6jVC -(65. rl4P- SOIL THC Y ARC a oA.t nzµ[rco /u If A fnr)' fnany GRgvEI rI497 I0E:RIf A -T /0 M/akr&5'11 .eAe. 7 -keV for I CoUfTRkcT6n py re1w)*r6R <rXrZAt Rwp LA T 2 tiaw IrpLELY ursS ME Exltr�Ntr wRfTEr..Ar4rA frfrr-m. rl•[E ;,)q 7-1 fY5TF, rt IN [QNF•ST/ov Ir /4IOMoal"7-t-Lr f-e(/eAfs SLora ov TI -CE S7AME (aar6w.R 9f 7 -MC W)4Trz)e t -Si 1. IAO' ¢'uFtTloAi, _v,FLL /IATA - THF- 9-W Ail Iv t IA.' 4446fT1on/ /S bS FEET PP -EP. 4.ArER IJ fAtcw,vrF.RCO Ar B/ FEET, TMO PXb'P0.k1.v/9hv7 sot /f t'[A Y , 6, flA 101 MIot 7'a ME /p -Ow IFFlZ pleOm rAtr 6N OgA,W X&R.& -CiF. � /Yis SO/L.. IS T yPl GgLL v 60Y Cov✓9"$I v#E r o rtec,+T/Owi,. fs pl"� c rKy, l FFFLuENr I� R vIrRY Sitmer Pifnowe6(2� 6vg7-6.2 514,"ALF 1N0/G14T t No pALTERYI9 PAvOS6owr *,wP 4'0- ANir 2R r<_ -S G6 TFCraf, ®® w0® Cl $, o ]� R. D• E. C. 5, P, Iti`. Cr. far S. C. 0. POIA'r s IvAiE1I rnRLE Ij- _ x�g37S.o S.3 sale. S°�9rioN ,/ C�gY � fs►,vn EQKat ,. �.0 6 rrr! n9m F Ga gyirivi /orFR r#oj-E 6x*j9/fiMJ"Ma3%2IKSLY O 1%SSuME a s6Rvv/a — S % 2.0 vRe � an�rr�e Se�aAT� adv 2aLX=z•v 2.8 ,Vel 1j,$10N 6,n6 -Nr wA1 vF/2 G Popp r�r�►� ALASKA WATER Ee WASTEWATER w1111 W4,wrt? CONSULTANTS. INC. �.;n crz„ u, .,=•veuac'•.^.-_: _, August 31, 2000 Municipality of Anchorage Department of Health & Human Services Division of Environmental Services On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 REFERENCE: Septic Adequacy Test results, Well Waiver requests, Lot Line waiver request, and other concerns for Lot 2, Block A; Glacier View Heights Subdivision SEPTIC ADEQUACY TEST: The existing septic system consists of a 1000 gallon septic tank and 116 feet total length of trench that includes 6 spill-over trenches that vary in lengths. According to the ADEC records, there is an effective depth in each trench of 2.5 feet. In the process of performing an inspection for the purpose of obtaining a Health Authority Approval, it was noted that the majority of the septic pipes (shown on the original ADEC inspection report) were not present. The property owner contracted with Hamann Excavating to install all of the necessary clean -outs and monitoring tubes. Also it should be noted that the neighboring property, Lot 1, Block A, Glacier View Height S/D, is no longer connected to this system and the septic tank which served this property was also completely abandoned by Hamann Excavating. On 5/26/2000, we returned to the property to perform a septic adequacy test (after all the monitoring tubes and cleanout had been installed). On the day of our inspection, we found the upper four trenches to be completely saturated and the two lower trenches were found to be dry. Attached is a as -built drawing showing all the new and exiting cleanouts and monitoring tubes. On 5/26/2000, a total of 624 gallons of water was first added to the monitoring tube labeled MT8 which caused the liquid level to rise to 11 inches from the bottom of the monitoring tube. An additional 423 gallons was added to the monitoring tube labeled MT10 which caused the liquid level to rise to 13 inches from the bottom of the monitoring tube. MT8 was checked 45 minutes after water had stopped being added and the monitoring tube was found to be dry. MT10 was checked 20 minutes after water had stopped being added and the liquid level was found to be at 9.5 inches from the bottom of the monitoring tube, a drop of 3.5 inches. Based upon this data, it has been determined that the septic system meets the MOA requirements for a 3 bedroom residence. WELL WAIVERS REQUEST: After the installation of the new cleanouts and monitoring tubes, the separation distances to the well serving this property and the well serving Lot 1, Block A, Glacier View Heights were measured using a Topcon GPT -1003 total station. Attached is an as -built drawing which shows the clean -outs and monitoring tubes relative to the wells. Based upon our field measurements it was determined that each well is a close as 98 feet to the septic system pipes. The actual separation distance to the edge of the drainfreld is slightly less. We are requesting that a 96 foot waiver be issued for the separation distance between these wells to the 6901 Debarr Road, Suite 2B— Anchorage, AK 99504— Ph: (907)337-6179— Fax: (907)338-3246 septic system on Lot 2. There is a 87 foot waiver for the well on Lot I to the septic system serving this property. Justification for the waiver/s are summarized as follows: ➢ Water samples taken at Lot 1, Block A, on 8/1/00 indicated nitrate levels of 0.5 mg/1 and no bacteria. ➢ Water samples taken at Lot 2, Block A, on 8/1/00 indicated nitrate levels of 0.5 mg/1 and no bacteria. ➢ The existing encroachment has existed for over 15 years with no adverse impact on the aquifer. Attached is a point evaluation that was performed for the 87 foot waiver (well to drainfield) on Lot 1, Block A. Although the well on Lot 2 is not as deep as the well located on Lot 1, there are confining clay layers that should protect the aquifer. Attached is a copy of the well logs for both properties. In short, there is minimal potential for there to be subsurface contamination of the aquifer. ➢ The drainfield is a series of terraced trenches that spill over into the next lower trench. If any trench were to overflow, the wastewater would run downhill, directly to the southwest, and not towards either well. In short, there is virtually no potential for surfacing wastewater to contaminate the well. ➢ The trenches are also in a visible area and if any effluent were to surface, the problem would be resolved very quickly. Based upon the aforementioned facts, it appears that there is minimal risk in granting the requested waiver/s (96 feet from the wells on Lots 1 & 2, Block A to the septic system on Lot 2, Block A). LOT LINE WAIVER REQUEST: We also request that a 5 foot lot line waiver from the southeast property line to drainfields be granted. We are unaware of any adverse effects of the granting of this waiver would have on the adjacent property. OTHER CONCERNS: It was also noted during our site visit that the most upper trench does not meet the 10 foot setback from foundation. It appears that the closest portion of the trench is greater than 5 feet from the foundation. This encroachment has existed for over 15 years and there has been no indications of this being a problem. It also appears that the elevation of the distribution line of this trench is at or deeper than the footing of the foundation. We do not anticipate any future problems with this encroachment and request the require 10 foot setback be waived to 5 feet. Also, it should be noted that the two lower trenches are under a portion of the driveway. During the excavation of the new cleanouts and monitoring tubes, it was noted that the trenches appeared to be well insulated. The standpipes that are in the driveway were installed with cast iron covers made for driveways in order to protect them from breaking. If you have any quest} s, please contact me at 337-6179. Thank you for your consideration of this matter. �� JeffretilA. Odmess\P.Y. M.S. 6901 DebaiT Road, Suite 2B — Anchorage, AK 99504 — Pb: (907)337-6179 — Fax: (907)338-3246 rAT-B-1 AS -BUILT DRAWING PARCEL ID NUMBER: 051-501-10 I \ LOT 12, BLOCK B, \ GLACIER VIEW HEIGHTS \ I LOT 3, BLOCK A, \ GLACIER VIEW HEIGHTS \ \ \ \ \ LOT 2, BLOCK A, \ \ aP9�Jh GLACIER VIEW HEIGHTS \ \ \ 1 / �HpsR0 FCOI' f,,\ LOT 1, BLOCK A, \ GLACIER VIEW HEIGHTS NOTE: THE SEPTIC TANK THAT SERVED LOT 1, BLOCK A, GLACIER \ VIEW HEIGHTS WAS COMPLETELY ABANDONED (IN PLACE). JE: op6`�Op 4 8/31/2000 0 :AWN BY: 0•`v •••• ••;7 ALASKA. WATER & WASTEWATER SCALE: C.J.G. CONSULTANTS, INC. , - -��• __ 6901 DEBARR ROAD, SUITE 2B `ANCHORAGE, AK 99504 `PHONE (907)337-6179' FAX (907)338-3246 1 " = 40, ...... ...... PREPARED FOR: PHONE NUMBER: PAGE NUMBER: WYNN BACKHOUSE (907) 696-2556 1 OF 1 Q fr A. Or -ss: LEGAL DESCRIPTION: QO y E-7953 GLACIER VIEW HEIGHTS SUBDIVISION; LOT 2, BLOCK A, �� fD^'•. cq,p� TYPE OF WORK: @dprof"11011111 AS -BUILT DRAWING OF SEPTIC SYSTEM FOR WAIVER REQUEST �Opp000p�� 20.81 14.05 R 12.79 9.33 9.34 CO3 28.61 26.35 MT2 28.60 26.77 C04 45.78 22.98 MT3 46.14 23.14 C05 32.75 34.48 MT4 32.29 34.50 C06 46.22 32.67 MT5 46.80 32.70 C07 33.49 46.49 MT6 33.78 47.12 C08 43.13 45.07 C09 44.99 63.20 MT7 44.24 63.02 C010 64.04 63.14 MT8 65.13 63.86 C011 154.88 77.17 Mrs 54.60 76.60 C012 77.58 77.02 MT70 78.48 77.89 AS -BUILT DRAWING PARCEL ID NUMBER: 051-501-10 I \ LOT 12, BLOCK B, \ GLACIER VIEW HEIGHTS \ I LOT 3, BLOCK A, \ GLACIER VIEW HEIGHTS \ \ \ \ \ LOT 2, BLOCK A, \ \ aP9�Jh GLACIER VIEW HEIGHTS \ \ \ 1 / �HpsR0 FCOI' f,,\ LOT 1, BLOCK A, \ GLACIER VIEW HEIGHTS NOTE: THE SEPTIC TANK THAT SERVED LOT 1, BLOCK A, GLACIER \ VIEW HEIGHTS WAS COMPLETELY ABANDONED (IN PLACE). JE: op6`�Op 4 8/31/2000 0 :AWN BY: 0•`v •••• ••;7 ALASKA. WATER & WASTEWATER SCALE: C.J.G. CONSULTANTS, INC. , - -��• __ 6901 DEBARR ROAD, SUITE 2B `ANCHORAGE, AK 99504 `PHONE (907)337-6179' FAX (907)338-3246 1 " = 40, ...... ...... PREPARED FOR: PHONE NUMBER: PAGE NUMBER: WYNN BACKHOUSE (907) 696-2556 1 OF 1 Q fr A. Or -ss: LEGAL DESCRIPTION: QO y E-7953 GLACIER VIEW HEIGHTS SUBDIVISION; LOT 2, BLOCK A, �� fD^'•. cq,p� TYPE OF WORK: @dprof"11011111 AS -BUILT DRAWING OF SEPTIC SYSTEM FOR WAIVER REQUEST �Opp000p�� March 25, 1997 Alaska Water & Wastewater 8471 Brookridge Drive — Anchorage — Alaska 99504 Phone (907) 337-6179 — Fax (907) 338-3246 Consulting Engineers uJAjv&2- R�� Municipality of Anchorage Dept. Health & Human Services Division of Environmental Services On -Site Services Section P.O Box 196650 Anchorage, Alaska 99519-6650 Subject: Waiver of separation distance from new septic system to existing private well. Lot 1, Bk A, Glacier View Heights S/D. Mile 4.8 (approx.) Eagle River Road. To whom it may concern: GENERAL: The subject property has a 3 bedroom house, served by a private well and a community septic system located on Lot 2, Bk A, Glacier view heights. The community septic system is operating in a surcharged condition, and therefore, will not pass an adequacy test. For various reasons (see the septic system design package) the proposed upgrade (serving only Lot 1) must be located such that the closest part of the trench will be only 85 feet from the well. The topography of the site is such that it is impossible for overflowing sewage (from the tank or trench) to run towards the well. The only potential for contamination would be lateral migration of wastewater from the new drainfield to the well. The contamination potential will be evaluated using the ADEC point system. Justification for this waiver is summarized as follows: ADEC WAIVER, POINT SYSTEM EVALUATION: Geological: According to the well log, the groundwater source is a confined aquifer, in gravel, approximately 134 feet below the top of the casing. The confining soil appears to be two layers of hardpan between 87-95 feet, and 125-134 feet. The combined thickness of the hardpan layers is 17 feet. Due to the fact that the groundwater source is confined, the drawdown on the well will not cause wastewater (from the septic system) to migrate towards the well: Effluent from the trench should follow the soil profile, and migrate downhill, away from the well. a. Distance from the bottom of the trench to groundwater: Water was encountered at a depth of 16.5 feet below the ground surface in the test hole monitoring tube; however, this is not the drinking water source, but vadose water. Water at this depth, above the confining soils, is moving laterally downhill, away from the well. For purposes of this evaluation, I am assuming that the confined groundwater source is our primary concern. The bottom of the new trench will be approximately 20 feet lower in elevation than the top ofthe well casing. According to the well log, the groundwater source was encountered at a depth of 134 feet below the top of the casing. Wastewater from the trench will percolate vertically through approximately 114 feet of soil (including 17 feet of hardpan) before reaching the groundwater source. This corresponds to 7.0 points. b. Soil sorption below the drainfield: According to the well log, the geological profile is as follows: 0-25 feet is silty gravel, 25-69 feet is silty sandy gravel with cobbles, 69-85 feet is silty gravel, 85-87 feet is medium gravel, 87-95 feet is hardpan, 95-125 wet gravely sand, 125-134 feet is hardpan, 134-144 feet is water and gravel. In summary, 87% of the profile (down to the gravel water bearing strata) is gravel and gravel mixed with silt or sand.. Approximately 12.6% of the profile is hardpan. I am going to assume a point value of 1.0 for the gravel mix soils, and 3.5 for the hardpan layers. This corresponds to a point value of 1.3, calculated as follows: (.87(1.0) + .13 (3.5)) = 1.3 points. c. Soil permeability below the trench: I assumed 1.0 for the gravel mix soils, and 2.5 for the hardpan layers. I believe these are reasonable assumptions. This corresponds to 1.2 points calculated as follows: (.87(1) i- .13(2.5))= 1.2. d. Water table gradient: When performing the well adequacy test (pumping at a rate of 5.83 gpm) the maximum drawdown was only 8 feet. Since the aquifer is confined, drawdown in the well does not induce a hydraulic gradient towards the well. The confined groundwater gradient should follow the contour of the confining soil strata, which slopes downhill from the well to the trench. In short, there is a positive hydraulic gradient, from the septic system to the well, of approximately +5% . To be conservative, I am going to assume a 0% gradient, which corresponds to a value of 2.9 points. e. Horizontal separation from well to trench: Given an 85 foot separation distance, the point value is 2.4 points. Total Points: 14.8 According to the ADEC waiver guidelines, a point value 12-16 indicates no bacterial contamination is possible, and that chemical pollution (from household sources) is unlikely. Recent water sampling/analysis (2/12/97) found no bacteria, and nitrate levels to be undetectable (existing separation distance is exactly 100 feet). Given these facts, it is my recommendation that the requested waiver (85 feet from well to new drainfield) be approved. If you have any questions, please contact me at 337-6179, or on my digital pager at 1-800-481-1162. Thank you for your assistance. Sincerely, Jeffrey A. Garness, P.E., M.S. Principal w� W l MUNICIPALITY OF ANC1i0RApE r��YY i Mtrx� 1Ye DRILLING Ine. DEPT. OF HEALTH R " ; P. O. Boa 4-1728 • • 2811 Dawson ENVIRONMENTAL PRp7ECTpf1 u'y ' A C 907-279-1741 t ANCHORAGE, ALASKA 99509 I rj 8Q " 3 sr s_ 'iTi1�` O nRiLLING LOG R EGE t f 6 D A"''.:$`�r�+'ra'�{:staa•r.,�i .' Larri Porter - - Use of WeTi off, Well -Owner �, trot Location ^(address of. Township, Range, Section, If known; or distance main road Flu: � dF';�.�'1 j'{,d i, `.�/ f)`� U' `i���L�F / /L�/✓ l'"/l - 1` t = a; rt zG4'` 'iaiT1•. a1 (; r -142 f Size7ofcasing Ci nepthof.Hole_145 feet Cased to42 ssi Statice�yvater leVe1 �' 6g. ft (ZoVe .'(below) land surface. Finish of well (check one) open end Screen,(�axk) , Perforated it �V1Fp: Yrs"I lone ^.... Des&1be.scmen or,perforati Welt=vptunping:',est;�at��"; gallons per (hoiir) (minute) for 1 --hours with >G WELL LOG Depth In feet from ground surfaee .. _ Give details of formations penetrated, size of material, color and hardness p Tp 29i scall Grsvelt rilty■ occasional nobbles Cobble Grevels silty/so d%' fouler bi,F, ;„ ( rl t tlty r,v 'r cchFl� SS yzr ri.O _ y".1diva Gavel loose }ordnrns ortwelly 4 a( $4 �qr+b Gre�ell °nndt vet +�kfater Gravel IN to arp vv[yde F. werther j AiNTOW $— C.ontrxetor MUNICIPALITY OF ANCHORAGE�� • DEPARTMENT OF HEALTH & HUMAN SERVICES �y} Division of Environmental Services j On -Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # n44() — 2+ n — �C) HAA # Ia��1�(�i1In 1. GENERAL INFORMATION Complete legal description Lot 2; Block A; Glacier View Heights Subdivision Location (site address or directions) Mile a R Ragle River Roar9 Pagle River Alaska Property owner Fannie Mae Day phone Mailing address Lending agency Day phone Mailing address Agent Virginia Kohfield - RE/MAX OF EAGLE RIVERDay phone __ 694-2979 Address 16600 Centerfield Drive, Suite 201, Eagle River, Alaska 99577 Unless otherwise requested, HAA will be held for pickup. 2. NUMBER OF BEDROOMS, 3 3. TYPE OF WATER SUPPLY: Individual well xxx Community well Public water NOTE: If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: Individual on-site XXX Holding tank Community on-site Public sewer NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA 921 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furtherverify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Phone Address 17034 Eagle River Loop Road No 204 Eagle River, Alaska 99577 Engineer's signature Date DHHS SIGNATURE __ Approved for bedrooms. Disapproved. Conditional approval for nw i1 t a :fn Trey %,,t it )- � HH••��yy y �i1`Yu il�✓lam' � •�. .tl l/5F A 6 3_15 bedrooms, with the following stipulations: Additional Comments SQ ze�� X�,{�(%C� By:� �!��� Date 1lITIC The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 1/91) Back MOA 421 Municipality of Anchorage Department of Health & Human Services _ HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: ��'� %i i .� �t✓I�L` 64 Parcel I.D. A. WELL DATA Cased to Casing height Well type V17AV Ami If A, B, or C, attach ADEC letter. Log present49N) V Date completed ADEC water system number 5 Driller Sanitary seal ON) \ Total depth Cased to Casing height 12 Sanitary seal ON) \ Wires properly protected &N) FROM WELL LOG AT INSPECTION Date of test Static water level 1 � u®mv CA Well flow �� g.p.m. �i•4 i g.p.m. M Pump level i®'f7 � SEPARATION DISTANCES FROM WELL TO: Septic/holding tank on lot \ OC> ; On adjacent lots Absorption field on lot t o(D ; On adjacent lots t � 1 Public sewer manhole/cleanout Petroleum tank I k oo' Public sewer main �k Sewer service line WATER SAMPLE RESULTS: Coliform bb 0-, Nitrate A V , Other bacteria Date of sample: Collected by: S & S ENGINEERING 17034 Eagle River Loop Road o. 204 B. SEPTIC/HOLDING TANK DATA Eagle River, Alaska 99577 Date installed Cleanouts(Y/N) High water alarm (Y/N) _ Date of pumping SEPARATION DISTANCES Wells) on lot To prop ine �f Surface water/drainage 72-026 (Rev. 7/91) Front 1 Tank size Foundation cleanout (Y/N) Compartments Alarmlested-(Y/N) Pumper C/HOLDING TANK TO: On adjacent I rption field Foundation Water main/service line CONTINUED ON BACK PAGE III G. LIFT STATION Date installed Size in gallons Vent(Y/N) High water alarm level Meets MOA electrical "Pump on" level at Manufacturer Manhole/Access (Y SEPARAZIf7N DISTANCE FROM LIFT STATION TO: Well on lot D. ABSORPTION FIELD DATA Date installed Length Total absorption area Width Depression over field (Y/N) Results (pass/fail) On adjacent lots Peroxide treatment (Past 12 months) (Y/N) Soil rating "Pump off" level at Cycles tested Surface water _ System type Gravel thickness Total depth Cleanouts present(Y/N) — Date of adequacy for If yes, give date SEPARATION DISTANCE FROM ABSORPTJe'N FIELD TO: Well on lot To building foundation On adjacent lot Surfac ater urtam drain n adjacent lots Cutbank Property line To existing or abandoned system on lot Water main/service line Driveway, parking/vehicle storage area (,,o V-A WA &� <S L �S o ��N� '- E. ENGINEER'S ERTIFI ATION bedrooms I certify that 1 have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. S & S ENGINEERING Signature 17034 Eagle River Loop Read No. 204 EauFe River, Alaska 99577 Engineer's Name Uc L tl l 3%1 Date 7© `� HAA Fee $ ,L Waiver Fee: $ Date of Payment �' - 9 Date of Payment Receipt Number Receipt Number 79.roR Iaa� 1/011 Aa,k UnA 91 Anchorage District Office 349-7755 800 E. Dimond Blvd., Suite 3-470 Anchorage, Alaska 99519 March 10, 1992 Mr. Roger Shafer, P.E. 17034 Eagle River Loop Road, Suite 204 Eagle River, Alaska 99577 Subject: Lots 1 & 2, Blk A, Glacier View Subdivision; Wastewater Disposal System Adequacy Test Dear Mr. Shafer: This is in response to your application for approval of the wastewater disposal system serving the above referenced properties. The adequacy test indicates that on the date of the test the wastewater disposal system was adequate to handle the volume of wastewater expected to be generated by the equivalent of a 6 bedroom residence. Therefore, the wastewater disposal system is approved for the concerns of this Department. The enclosed signed Approval of On -Site Residential Water and Sewer Systems certificate constitutes this approval. Sincerely, Bill Lamoreaux, P.E. District Manager J Byfon Environmental Engineering Assistant Enclosures: As Stated V OF Ty STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION ' = APPROVAL OF ON-SITE RESIDENTIAL WATER AND SEWER SYSTEMS Ui'-a�-RIS r F ALAS— PROPERTY DESCRIPTION Lot, Block & Subdivision or U.S. Survey V 1 1 / l--O`t5 �4 ?1. ) 4y� l/ Oj CA AT � c F r r�v I,' S ��n�ii g � o'Y E q, o f� v/,_ Y- j 1 K Certificate Issued for Application No.: `t 221 -Pbod ,)- 0/:)1 This approval does not constitute a guarantee of any kind, explicit or implied, as to the performance of the water supply and wastewater disposal systems. WATER SUPPLY A rec the wale - ample was tested and found to meet Department of Enviro�entat'Con res vation drink- ing water standards for total-colliform bacteria. Name WASTEWATER DISPOSAL The domestic wastewater system was: Date ❑ inspected by the Department of Environmental Conservation and found to be in compliance with applicable requirements of 18 AAC 72; ❑ inspected by a Professional Engineer who certifies that the system complies with applicable re- quirements of 18 AAC 72; ❑ installed by a Certified Installer who certifies that the system complies with applicable requirements of 18 AAC 72; or tested by a Professional Engineer who certifies that the performance of the system is satisfactory and that the system complies with the minimum separation distances specified in 18 AAC 72. This approval is valid forR R single family ❑ multi -family unit with a total of bedrooms. 180404(Rev. 8/85) DISTRIBUTION: WHITE—BANK/LEN DING INSTITUTION; CANARY—APPLICANT; PINK—DEPARTMENT - - - - - (d) Lending Institution ON �� � Pei, Telephone Address (e) Real Estate Company and Agent Address Telephone (f) Mail the HAA to the following address: S & S ENGINEERING SR B 196X EAGLE RIVER, AK 99577 A. WELL DATA MUNICIPALITY pMUNICIPALITY OF ANCHORAGE (MOA) DEPT. OF IF�&#f'AUTHORITY APPROVAL (HAA) ENVIRONMENTAL PROTRJFMLIST - FEBRUARY 1984 264-4720 _ ; ) 9986 RECEIVED Legal Description: L� 2 Well Classification S F• If A, B, C, D.E.C. Approved (Y/N) Well Log Present dYN) Date Completed ' I ,B5 Yield 300 [–, pti r �� Total Depth fir% Cased to Depth of Grouting "'— Static Water Level �� r Pump Set At Casing Height Above Ground — Electrical Wiring in Conduit (9/N) '�'po9Sanitary Seal on Casing (DN) Depression Around Wellhead (Y/ J4) Separation Distances from Well: t To Septic/Fielding Tank on Lot iso ; On Adjoining Lots oD ) To Nearest Edge of Absorption Field on Lot t on I ; On Adjoining Lots t ad 1k To Nearest Public Sewer Line E' To Nearest Public Sewer 1k Cleanout/Manhole To Nearest Sewer Service Line on Lot 2-s Water Sample Collected by S Su 1c1r1�4�. ; Date 7-) Water Sample Test Results �/�'�1S Comments B. SEPTICA40t6tlgG TANK DATA Date Installed (o'ZZ – 55� Size 7 000 No. of Compartments Standpipes((/N) 2 - Air -tight Capso/N) Foundation Cleanout &/N) Depression over Tank (Y J Date Last Pumped Ncfi IA! USE �61_ Pumping/Maintenance Contract on File (Y/N ; for Holding Tank High -Water Alarm (Y/N) Temporary Holding Tank Permit (Y/N) A Separation Distances from Septic/Holding Tank: To Water -Supply Well 1 b� To Property Line To Water Main/Service Line Course To Building Foundation To Disposal Field To Stream, Pond, Lake, or Major Drainage Comments At6 W6 1&>51 so -my v Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata ��6/ti Type of System Designer-� Date Installed 2-8 5 Length of Field r � i Width of Field S Depth of Field Z Gravel Bed Thickness Z 1z Square Feet of Absorption Area �/ DIS Standpipes Presento/N) Depression over Field (Y/)p Results of Last Adequacy Test Separation Distance from Absorption Field: 1-�/a of Last Adequacy Test /A--, W To Water -Supply Well DD To Property Line To Building Foundation �_- bo Lot N To Water Main/Service Line To Stream/Pond/Lake/or Major Drainage Course 4 - To Existing or Abandoned System on On Adjoining Lots 56-f Ln,<-+-,t!xJ7-�r To Cutbannk (if present) P To Driveway, Parking Area, or Vehicle Storage Area Gl" Comments T/iie / f( G> Ego SLc>e? t/E5S /74o us ,a,J-v D. LIFT STATION Date Installed Size in Gallons Dimensions Manhole/Access (Y/N) "Pump On" Level at - "Pump Off' Level at High Water Alarm Level at Vent (Y/N) Tested for Pumping Cycles during Adequacy Test. Meets MOA Electrical Codes (Y/N) Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed S & S ENGINEERING Date JUL 2 1986 Compa SR B 1915X MOA No. �S U� 3 +�►sww EAGLE RIVER, AK 99577 Receipt No. "Z . Date of Payment Amount: $ e Page 2 of 2 72-026 (11/84) / 3 bu Ll DEPT. OF ENVIRONMENTAL CONSEH"TION R ANCHORAGE/WESTERN DISTRICT OFFICE 437 "E" STREET, SUITE 303 ANCHORAGE, ALASKA 99501 July 1, 1985 S & S Engineering SRB 196X Eagle River, Alaska 99577 R -( Y., A BILL SHEFFIELD, GOVERNOR 274-2533 SUBJECT: Lots 1 and 2; Block A; Glacier View Subdivision, Eagle River, Alaska 8521 -DA -163 Dear Sir: The Department has reviewed the Engineer As -built plans for the subject project. Final approval is hereby given for the sewer and water systems. e Certificate to Opera e is attached for th Any future expanc ono esu Sect project will requi `additional approval from this office. \ 'I (d swE/aa � q Sincerely, Steve Eng, P. E. District Engineer STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION APPROVAL OF ON-SITE RESIDENTIAL WATER AND SEWER SYSTEMS PROPERTY DESCRIPTION Lot, Block & Subdivision or U.S. Survey "/�� Z J � 1 06 /a c U i � 1' l/U-e yt/ Ju� �/�t�/Ji 0/1 ;lLay /C / L i Certificate Issuedto, Application No.: esz/ _A4 -/c3 The Department of Environmental Conservation does not guarantee the continued satisfactory perform- ance of the water supply and wastewater disposal systems. The validation dates are based on evaluation of the systems using accepted engineering practices and assuming satisfactory maintenance. WATER SUPPLY The water system has aI ated and found to comply with 18 AAC 80, satisfying standards for system construction and water qua 1 af.Class C water supplies and for minimum separation distances as appropriate. This approval is valid for months for he 4AJater-Sup0iy S -stem from date of issuance, pro - WASTEWATER the system is properly maintained. ---'" WASTEWATER DISPOSAL The domestic wastewater treatment and disposal system has been evaluated and has been found to be in compliance with 18 AAC 72 for a ZjXsingle family] []multi -family unit with 6 total bedrooms, satisfying the requirements for design, sizing and construction of a wastewater disposal system. This certificate is valid for 1�6� months for the Wastewater Disposal System from date of is- suance, provided the system is properly maintained. Receipts for Septic Tank Pumping, which is required every 24 months, must be retained for a valid approval. Name / Title I Date 251 '14 18-0404(6/82) Distribution: White -Bank/Lending Institution; Canary - Applicant; Pink - Department