HomeMy WebLinkAboutGREAT LAND ESTATES #1 BLK 2 LT 6Great Land Estates #1 Block 2 Lot 6 #051-131-10 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 Page / of Z www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW090135 PID Number: 051-131-10 Name: Dennis & Connie Walden Wastewater System: ❑ New Upgrade Address: 23716 Greatland Drive, Chugiak, AK, 99567 ABSORPTION FIELD Phone: Number of Bedrooms: 907-688-2021 5 ❑Deep Trench 16 Shallow Trench [I Bed El Mound ❑Other: Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION 0.6 8.917.5 GPD/Ftz Ft. Block Lot: Subdivision: 2 6 Depth to pipe bottom from original grade: Gravel depth beneath pipe: Great Land Estates #1 3.2/2.5 Ft 4.10/4.21 Ft Township: T15N Range: R1 W Section: SEC1 O Fill added above original grade: Gravel Length: 0.5-1.72 Ft. 128 Ft. Well: ❑ New ❑ Upgrade Gravel width: Number of lines: 2 Distance between lines: 15 5 Ft. Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Private - EXISTING Ft. Ft. 1280 Ft' ASTM 3034 Driller: Date Drilled: Static Water Level: Installer: Date Installed: Ft. Whitters Excavating 8/29/09 Yield: Pump Set at: Casing Height Above Ground: TANK GPM Ft. Ft. SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding ublic/Private Manufacturer: Capacity: From Tank Field Station Tank Sewer Line Anchorage Tank 1500 Gal. Material: Number of Compartments: well +100' +100' ---- ---- +25' Steel (10 gauge) 2 Surface Water +100' +100' ____ ____/I LIFT STATION Size: Manufacturer: Lot Line +5' +10' ---- ____ NO LIFT Gal. "Pump on" level at: "Pump off' High water alarm at Foundation +5' +10' Pump Make & Electrical Inspections performed by: Curtain Drain ____ *NA ---- ---- Remarks * None Known BENCH MARK Location and Description: Existing tank and seepage pit abandoned per code. TBM = Garage Floor (NE Cor of cement slab) Assumed Elevation: Pipe insulated under driveway 103.38 Ft. Engineer's Stamp Inspections performed by: Aaron Jarnagin (VEI Consultants) Dates: 1st 8/27/09 _:�O®®� e OF A `� 2"d 8/29/09 Development Services Department Approval ��Q'�� ® " Conditional Approval Date:®. 0. ... • ... . . ....... •.:-10.. �• p AARON I ARRAGIN �� Reviewed and approved by: k��/Date: (fi �/ e1 ��'h�" • ... • • �a (Rev. 04/06) ® PROFL-'SS00-. AS -BUILT SYSTEM DETAILS/SITE PLAN PERMIT No. SW090135 GREAT LAND ESTATES #1 BLK 2 LOT 5 PID No. 050-131-10 WELL RADIUS i GREA TL AND D�IVE_l 0 0 � TH2 CLEANOUT O MONITOR TUBE {} G PROPERTY LINE _ _N89' S5' 36.�y0=E _ 300.00' BENCH MARK / / J / BOTTOM OF TESTHOLE CO = CLEANOUT o 26.5' i SOUTH TRENCH \�� v c / o a BOH 8.0 - - - - - - - - - - - - - - - - _ 10' SLOPE MAINT ESMT - - - - - - - --- - -- - - 0 W/ CLEANOUT AS -BUILT SYSTEM DETAILS / SITE PLAN GREAT LAND ESTATES UNIT NO. 1 \ OLD SEEPAGE PITLi \ \ / T15NR1 W SEC 10 ZNORTH TRENCH INSULATION --, E I >_ w --], I F NEVA 1500 o ®TH1 TH3 \ SEPTIC TANK 0 0 � TH2 CLEANOUT O MONITOR TUBE {} G ® TEST HOLE D BENCH MARK / / J / BOTTOM OF TESTHOLE CO = CLEANOUT o 26.5' i SOUTH TRENCH \�� v c / o a BOH 8.0 o f K 10'i UANICS FLOW DIVIDE4 \ \ HOUSE VEI CONSULTANTS 0 W/ CLEANOUT AS -BUILT SYSTEM DETAILS / SITE PLAN GREAT LAND ESTATES UNIT NO. 1 0 NEW 5°x64° \ \ / T15NR1 W SEC 10 o z DRAINFIELD 100' WELL RADIUS / SWING TIES B -D =19.9 C -D =30.8 C -E =38.6 B-E =19.5 A -F =66.8 B -F =75.9 A -G =109.2 B -G =142.3 A -H =120.3 B-H =149.5 A -J =135.9 B -J =172.9 A -K =168.3 B -K =206.6 A -L =160.8 B -L =201.7 ®4 LOT 6I 0 0 101.5 FINAL GRADE 5 6.4 6.4,1 TANK " 1500 GAL 5.8 SEPTIC TANK (STEEL -toga) SCALE: N.T.S. / TBM: GARAGE FLOOR / # ; / ELEV 103.38 / o I 1 / n J Q GARAGE U I NORTH TRENCH 00 2.5 In In f�FINAL GRADE In In 2.7 00 VJ U U TANK OUT LEGEND • CLEANOUT O MONITOR TUBE {} WELL ® TEST HOLE D BENCH MARK BOH = BOTTOM OF TESTHOLE CO = CLEANOUT MT = MONITORING TUBE --/`-FILTER FABRIC VARIES ------ ---- 0.4° 0°° o 0 0000000 0 0 0 0 -0-0-0 > 0 0 0 0 0 0°0 0 0 0 0 0 0 0 0 0 0 0 0000 0 0 0 ° 0 0 0 0 0 o 0 0 0 0 0 0 00000000020000 0 0 0 0 0 0 0 0 4 21' 0 0 0 0000_0n_o„o 0 0 0 0 0 0 > 0 0 0 0„0 coo 0 0 0 0 0 10 0000_0 0_0„0_0 000 0 4 7 SEWER ROCK 4 7 0 64' - BOH 8.0 NO WATER FOi 00 mi SOUTH TRENCH 00 n In FINAL GRADE In n 3.0 FILTER FABRIC -------- - ----- VARIES 0.4° I 0 ° o o°°°°°° 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O 0 0 0 0 0 0 0 0 0 0 0000000 0 0 0 0 0 0 o 0 0 08.9 0 0 0 0 0000000 0 o 0 0 o O O O ° 0 0 0°0 0 0 0 -0.0.0-0,.2.0- o 0 0000 0 .00 0 0 O�O„O ^ n_O,iO o 0 0 0 0 0, 000 0 0 0 0 o o 4.10 ° o0�0_0 °_O�O_0�°00 4 g SEWER ROCK 4 8 0 ° BOH 8.0 r, 64' SCALE: N.T.S. NO WATER FOUND VEI CONSULTANTS 1345 RUDAKOF CIRCLE AS -BUILT SYSTEM DETAILS / SITE PLAN GREAT LAND ESTATES UNIT NO. 1 VEI LOT 6 BLOCK 2 Consultants T15NR1 W SEC 10 SCALE: 1'=40' DATE: 10/5/09 1 GRID: NW1260 Pg 2 OF 2 Civil Engineering and Surveying Consultants 1345 Rudakof Circle, Suite 201 Serving All of Alaska Anchorage, Alaska 99508 FAX: (907) 338-5386 Phone: (907) 337-3330 October 5, 2009 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Re: On -Site Wastewater Disposal System Inspection Report for Great Land Estates #1, Block 2, Lot 6. T15N R1 W SEC10, Grid NW1260 Permit No. SW090135 Dear Onsite Services Engineer, Installation of the On -Site Septic System components on the subject property is complete. The site plan and as -built system details are presented in the attached drawing. We request that you approve the attached Inspection Report. If you have any questions or need further information on this system, please contact me at 337-3330. Sincerely, VEI ,COI�SULTANTS Aaron D. Jam PE Attachments: Wastewater Disposal System Inspection Report As -Built System Details/Site Plan 1 "=40' pts OF A\�s'i �. r AW low . ... m . ..�. / •. AARON o. �aC el�� • Na. C 14,538 . .w 0®PRoFEssioO�� MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Aug 04, 2009 Expiration Date: Aug 04, 2010 Permit Number: SWO90135 Parcel ID: 051-131-10 Legal Description: GREAT LAND ESTATES #1 BLK 2 LT 6 Design Engineer: 0887 VEI CONSULTANTS Site Address: 023716 GREATLAND DR Owner Name: DENNIS & CONNIE WALDEN Lot Size: 90000 SO. FT. Owner Address: 23716 GREATLAND DRIVE Total Bedrooms: 5 Permit Bedrooms: 5 CHUGIAK . AK 99567-0000 This permit is for the construction of: ❑✓ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By. b -L' Date: 04C 9 Date: 'q16 / G t Municipality of Anchorage P.O. Box 196650 • 4700 Elmore Road Anchorage Alaska 99519-6650 • (907)343-7904 • Fax(907)343-7997 http:lhvww.muni.org/Onsite Development Services Department On -Site Water and Wastewater Program menr DepartIII ell t **** VARIANCE/WAIVER REVIEW **** WR#: 090046 HAM Permit#: 090135 PID#:051-131-10 Legal Description: Great Land Estates #1. Block 2 Lot 6 Engineer: VEI Applicant: Dennis and Connie Walden Your request for a waiver of the required 50' from an absorption field to a slope greater than 25% has been approved. See the permit package for the approved design. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ............................................................................... Waiver is Granted: X Waiver Is not Granted: Date:/8 4/09 Approved by: ,,ee z1t - �t Name of Reviewer - ............................................................:,................. Rec#: 122954 Amount: $200.00 Dale Paid: 7128109 **** VARIANCE/WAIVER REVIEW **** Municipality of Anchorage -Yl Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, Alaska 99507 www.muni.org/onsite (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051 13110 000 18 Property owner(s) Dennis and Connie Walden Day phone 907.688-2021 Mailing address 23716 Greatland Drive, Chugiak, AK Zip Code 99567-1646 Site address 23716 Greatland Drive, Chugiak, Ak Zip Code 99567-1646 Legal description (Sub'd., Block & Lot) Great Land Estates #1, Block 2, Lot 6 Legal description (Township, Range & Section) TI 5N R1 W SEC 10 Lot Size 90,000 Sq. Ft. THIS APPLICATION IS FOR (® all that apply): Absorption Field n Septic Tank El Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms 5 THIS APPLICATION IS AN: Initial ❑ Upgrade El Renewal ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: $5330 Waiver Fees: ;2-D a / Date of Payment: 11 q/0 l n Date of Payment: 2--Z 5? " 0 2 Receipt Number. 127, 912 Receipt Number. / A Z !E� S (Rev. 11 t05) Civil Engineering and Surveying Consultants 1345 Rudakof Circle, Suite 201 Serving All oJAlaska Anchorage, Alaska 99508 FAX: (907) 338-5386 Phone: (907) 337-3330 July 27, 2008 Mr. Dan Roth, Supervisor, On -Site Services Municipality of Anchorage On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Re: On -Site Sewer Upgrade for Greatland Estates #1, Block 2, Lot 6 TI 5N RI W SEC 10, Grid N W 1260 Permit Application Comment Response & Waiver Request Dear Mr. Roth, VEI Consultants Received comments from your office for the subject permit dated July 20, 2009. We have addressed the remarks and are submitting the additional information and response to each comment as follows: 1. A sand filter will not be used on the system. Material specifications for filter material have been removed from the design specifications. 2. A roadside ditch with side slopes greater than 25% exists within 50ft of the proposed disposal field. We request you grant a 31.5' separation distance waiver from the top of slope of the ditch to the disposal field. Information pertaining to this request and justification for the waiver are as follows: a. The primary disposal field is located in a relatively flat area at the toe of an existing hill on the lot. Topography dictates this is the best location for the disposal field minimizing the construction effort of placing the absorption trenches on the side slope of the hill. The current location also minimizes tree removal during construction. b. A cross-section of the disposal filed and roadside ditch was developed per the requirements of the MOA Building Safety Division Memorandum "Slope Setbacks from >25%" dated April 7, 2004. As shown in Figure 4, a grade line of 25% originating at 2.5R above the distribution piping and drawn perpendicular to the distribution pipe does not daylight within 3511 On -Site Sewer Permit Application for Lot Greatland Fstates # 1. Block 2. Lot 6; T/3N R111' 510.: Grid N117260 Page 1 of 2 horizontally from the absorption trench, thus satisfying the conditions of the memorandum. c. As shown in the attached soils logs, no groundwater or impermeable layers were encountered within the vicinity of the disposal field. Additionally, the roadside ditch is shallow, averaging 2-3ft in depth, and sees only seasonal runoff during times of peak snow melt; therefore we anticipate no adverse effects in locating the disposal filed within 50ft of the ditch side slope. 3. The drawing scale on Figure 2 has been corrected (see attached) 4. A reserve field has been designed. VEI conducted field investigations including digging a test pit and performing a percolation test for the reserve field location. The Soils Log—Percolation Test for Test Hole #4 located in the vicinity of the proposed disposal field is attached. No groundwater was observed in these test holes/monitoring pipes. Immediate neighboring septic systems are all more than100' away, and no private wells within 100' or community wells within 200' of the reserve site. Existing grade was verified in the field and no slope greater than 25% is within 50ft down gradient from the reserve field location. Groundwater monitoring is ongoing; however, we do not anticipate groundwater in the monitoring tube. The percolation rate for the reserve field is 13minutes/inch which will require a smaller absorption trench system than the primary location. Per the Wide Drainfield Design Specifications, the reserve system will require two 4711 trenches at 511 wide and with 48inches of gravel below the distribution pipe. 5. Specifications have been revised to include decommissioning of the existing crib. 6. Absorption field design has been revised to allow connection of the gravity line at the midpoint of the absorption trenches. (see attached) 7. Soils logs have been updated to include Unified Soils Classification designations. 8&9. New percolation tests were performed in accordance with Table 3-8 of the EPA Design Manual. Percolation test results are attached. 10. The application rate on Figure 2 has been corrected (see attached) 11. An additional test hole and percolation test was performed in the vicinity of the primary disposal field. Soils Log and Percolation Test for Test Mole #3 is attached. As shown in Figure 2, the additional percolation test provides complete coverage of the disposal filed within a 30' radius of Test I tole #2 and #3. The average percolation rate is 22.7min/inch. 12. Septic Tank Installation Note 2 of the Construction Specifications directs the contractor not to exceed burial rating of the tank. A note has been added to the design plans Figure 3 for additional clarification. 13. The design plans have been revised to show the double cleanout as specified. 14. A cleanout has been added at the midpoint of the gravity line from the tank in compliance with UPC code. A note on Figure 3 has been added indicating the 100ft maximum distance between cleanouts. (see attached) I5. The intent of Absorption Trench Spec #8 is to ensure accepting soil within the trenches meets the requirements of the design. Spec48 has been revised and additional information has been added instructing the contractor to contact the engineer if unsuitable material is encountered. Onsite Sewer Permit Application for Lot Greatland Estates V, Block 2, Lot 6; Tl5N R111'S10.: Grid NII'1260 Page 3 of 2 We request that with this additional information the On -Site Sewer Application Permit be approved and the distance to 25% slope waiver be granted. Based on the aforementioned facts under comment response #2, it appears that there is minimal risk associated with granting the 31.5ft separation distance waiver. If you have any questions, please contact me at 337-3330. Sincerely, VEI CONSULTANTS�.v�� v ' Aaron D. Jamagin, PE cc: Vernon L. Roelfs, PE President, VEI Consultants f OF Al p 1 �AARON D. • • • •WN..* 1 °A NoCE 11538. 1 FDS �-oq •P Attachments: Overall Site Plan 1"=100' Proposed Septic System Plan Proposed Septic System Profile Slope Separation Plan R. Profile Construction and Material Specifications Soils Log — Percolation Tests for Test Holes 2,3,4 Separation Distance Waiver Fee Payment Check Civil Engineering and Surveying Consultants 1345 Rudakof Circle, Suite 201 Serving All ojAlaska Anchorage, Alaska 99508 FAX: (907) 338-5386 Phone: (907) 337-3330 July 10, 2008 Mr. Dan Roth, Supervisor, On -Site Services Municipality of Anchorage On -Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Re: On -Site Sewer Upgrade for Greatland Estates # 1, Block 2, Lot 6 TI 5N RI W SEC10, Grid NW1260 Narrative and Permit Application Dear Mr. Roth, VEI Consultants was contracted to design a septic system upgrade at the above referenced property. The homeowner wishes to upgrade their septic system, due to the age of the existing system and desire to add two additional bedrooms to the existing three bedroom house for total of (5) bedrooms. The proposed house, well and septic system locations are shown on the attached Site Plan, Figure 1. We request that you approve the attached permit application for construction of the septic system. VEI conducted field investigations including surveying, digging test pits, performing percolation tests and monitoring groundwater. The Soils Log—Percolation Test for Test Holes 41 and #2 located in the vicinity of the proposed disposal field are attached. No groundwater has been observed in these test holes/monitoring pipes. No seasonal surface water has been observed collecting anywhere on the property. The general slope of the lot is from southeast to northwest at a grade ranging from 5-18%. The proposed septic design, presented in Figures 2 R 3, includes a gravity line from the house to a 1500 Gallon septic tank, a gravity line from the tank to disposal field, and a total 126 LF of five wide trench (divided into 2 parallel runs) with 48" of gravel beneath the horizontal perforated pipe. The locations of all system components including clean - outs and monitoring pipes are shown on the Septic System Plan, Figure 2. The proposed system will not alter the existing site topography or drainage patterns beyond the limits of the disposal field. The ground surface above the disposal field will On -Site Sewer Permit Application for Lot Greatland &tater Hl, Block 1. Lot 6; TISN RIW S10.; Grid NW1260 Page 1 of 2 be filled up to I foot above existing to ensure that surface water does not collect above the trenches. The area will be graded to ensure positive drainage across the disposal field. Immediate neighboring septic systems are all more thanl40' away, and no private wells within 100' or community wells within 200' of the proposed septic system. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 337-3330. Sincerely, VF CONSULTANTS^ ��°� , Aaron D. Jamagin, PE cc: Vernon L. Roelfs, PE President, VEI Consultants Attachments: On -Site Sewer/Well Permit Application Overall Site Plan 1"=100' Proposed Septic System Plan Proposed Septic System Profile Construction and Material Specifications Soils Log — Percolation Tests for Test Holes 1 & 2 Fee Payment Check � \ n r -- — TergZ M.00 00 , OS .s \ W i ZU�NO w wu �0 , F$ ,00 OSL ",00.00 ,SO .ON I I I T a m 3 z��W1p�g aq. " 0 J c WZ 8 / gF - M_00'00 ,SO .ON I M 7 1 � I I e 317 � 1 n " ogt � Z i I I zI g� �; \gl I o Q W 1 I �T.00'OLL M.00 OO�.ON J g I /Fjig / \`\8n g 0t. \Y� N 1J / \ Woxx I 1 11 \ \ W `1J I°I� I I " $O h ,00'OOC M,00'00 ,SO .ON III II/ V1" M I \ � I II _I----_ _ —_ -- --_—__—__—_— _ WD wb oDS w+^O - 1 03\boroq\blo>i wD�DM\ 5 '3"43113 DNWVN0 , Z 5 ur I 1 J _ I J I ,00.OLZ M,00'00 ,SO .ON � 1 J L1 r\ I I •8 � $O h ,00'OOC M,00'00 ,SO .ON III II/ V1" M I \ � I II _I----_ _ —_ -- --_—__—__—_— _ WD wb oDS w+^O - 1 03\boroq\blo>i wD�DM\ 5 '3"43113 DNWVN0 c 01 W V) D O 2 CDNno,o,'Nn Lo SOI Of ln�tp0 NN �N�nf�01�0, V Vm'�OmmnOhtOhMOMi QNi 11 II II II II II II II II II II II 11 II II II II II II II OW�W4.2U' �la_SU�li2CJ�li2U'� I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 m m U U1M M M M N N N N J J J J y y y Y CL m CL CL CL aaa 00000 U U U U U U U U w / i / / Of co W J .06 \ I \ o f No Dl, 0\P N W r = m O M 0 Jm^ 00 in X. W Z U J , QZ co F W • Q �®® O \ I ! ❑ r� W I1I'i % l i II` 1WI 1 !oW •� z / i / / Of co W J .06 \ I \ o f No Dl, 0\P N W r = m Y a 7 K 0 Jm^ 00 2 O Z W Z U WWJ �V.JI Z m Vv i 3 Z F W • Q �®® O 3NIl A183d0bd ,OO.00C M„00'00 ,SO .ON u•J\sum�m�\o•io.g wp�oiy\ 5 OM1•/NJ NJ 9NM.�tlO C\210.3 / ❑ r� 3NIl A183d0bd ,OO.00C M„00'00 ,SO .ON u•J\sum�m�\o•io.g wp�oiy\ 5 OM1•/NJ NJ 9NM.�tlO zc ♦♦ ft✓/ / ♦ / W g m � • a 2. 10 Jm �_I T '• m P Q•1 'O0/ / O O v � V� •\: � I � � W ^ < Or �d •AU cff I .1 rc ff a w n 111 II}°G ♦♦ j a o a� a 0w pp' t ¢ jY <0, 6 u G'7 m� 1 `��m. WU r`=ON 'S 1HON381 N33M138 n > v Fa N (31n10 JA N a d �/1 W pp U R WK yy ff g mTW �a ao dA jjjpdR�( Zp i< > s 1iao:� m �a OW a! —0 O V� \/---I J 2- , & 8 O W O V I w U J Wpm J 1,Jj �W z $ €x0 WW N IfN Y U Wp Z Z C2F < W < 4 U JOS FWW sO�aaj 0 y ZN <ZG OWN C Ld L4 z N<Na Waz Y 0 ^ p O~ Wpz O m m ZZ pW FtiV iz3 W 74 uw0 2 1�/IOWNm U 60, Z NW -Ow� 0 O O<v < ��d mZV u_y pyR J <p yj FAD S��N> J < bd 6a zm J<p JmW O N-11WF k1«Fo Z q mO.Z VF«'J U SW pz8 �,JrczwbxjO$$oa �z �N SN W�ZW1-a Ot ZW� N if f m Z OV b�V YI'loi� uNWS JIWS - ( >�^b'3\�6��0<I\.t!16�5 WDibM� I �IM1311111.1 O p 8 I r sru1. �ai�taWa�j^d W ••l� W ICU '� �� � �� •fid N.� T O U6 iLL W � Y�IjS',rym� Z =s ZOI �{pyyer� �"� U'< // WV12N <W F; �nJW �/JO p 3�OW OZUim J � �C,• pJU SSW_ �2yW 1J/W -FNS V' O a U / 1'(m'�r2 rc ppl / ao rcom hZ / N �00F� 5 N zWc<o k YWW h Z Z / ,I `Of WJ W 7 LI � JY u ui�z + 8Y1ZW \ J I Civil Engineering and Surveying Consultants 13.15 Rudakof Circle, Suite 201 Serving All ojAlaska Anchorage, Alaska 99508 FAX: (907) 338-5386 Phone: (907) 337-3330 August 3, 2009 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES AND MATERIAL SPECIFICATIONS LEGAL DESCRIPTION: Greatland Estates #1, Block 2, Lot 6 GENERAL: 1. The scope of this project includes the upgrade of an existing septic system by installation of a 1500 gallon septic tank and a leach field trench to serve a 5 bedroom single family residence located on the referenced property. 2. Construction shall be in accordance with the approved site plan and design drawings, municipal permit with any special provisions or conditions, and all applicable Municipal Wastewater Disposal Regulations. Any deviation from the site plan and design drawings requires engineer approval. 3. Contractor shall verify the septic tank and absorption system are a minimum 100' away from any private wells in the area. 4. The contractor shall be responsible for obtaining any necessary underground utility locates. 5. Any remaining test -hole excavation shall be filled and monitor tube removed. 6. Contractors installing wastewater disposal systems must be certified by the Municipality of Anchorage On -Site Water and Wastewater Department for systems installations. Owners installing their own systems must also receive prior approval from the Municipal On -Site Water and Wastewater Department. SEPTIC TANK INSTALLATION: 1. Septic Tank shall be a minimum of 1,500 gallon tank of MOA approved construction, placed with 4 -foot minimum soil cover. The contractor will ensure that tank installation conforms to manufacturers specifications for depth of bury, backfill type, and compaction requirements. 2. Septic Tanks installed with less than 4 foot of cover shall be insulated. Minimum cover with insulation shall be 2 feet. 3. The sewer piping from the existing house cleanout to the septic tank shall be 4 inches laid at a 2% minimum and insulated with 2" insulation if shallower than 3f1, with 2fi minimum bury. 4. Construction shall include two 4 inch cleanouts for pumping access to the septic tank. All stand pipes on the septic tank shall extend to a minimum of 12 inches above final grade On -Site Wastewater Disposal System —Specifications. Lot Greadand Estates kl. Block 2. Lot 6 August 3. 2009 Page 2 of 3 5. In the line between the tank and the absorption system there shall be two adjacent cleanouts. The cleanouts shall be located on undisturbed soil not more than ten feet from the tank. The first cleanout in the line shall be to clean the line toward the absorption system and the second cleanout will be oriented to allow cleaning toward the septic tank. 6. The sewer piping from the septic tank to the absorption system shall be 4 inches laid at a 2% minimum and insulated with 2" insulation if shallower than 3ft, with 2ft minimum bury. 7. The septic tank shall be sufficiently bedded with proper material and compacting to prevent settling or shifting of the tank. 8. The contractor shall abandon the old tank and seepage pit in compliance with the Uniform Plumbing Code. ABSORPTION TRENCII INSTALLATION: 1. Excavate the proposed trenches in the location and to the dimensions shown on the design. Contractor shall ensure that 10 feet separation distance is maintained between trenches. The bottom of the trench shall be within 2 inches of level. 2. Once the sewer rock is installed, the distribution pipe shall be installed level with perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. Perforated pipe used in gravity subsurface disposal fields shall be 4 inches in diameter. 3. A silt barrier must be installed between the final gravel layer and the native soil backfill. Contractor shall ensure that the silt barrier covers the entire gravel surface before placing backfill. 4. Monitor tubes shall be of 4 inch diameter, installed approximately in the locations shown on the design, and extended a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distributing pipe. 5. A flow splitter (Quanics Plow Divider: GDS-ZS300, or equal) shall be placed to ensure even flow to each trench. 6. Backfill over the final gravel layer must not be less than 24 inches. Insulation shall be installed when the backfill depth is less than 36 inches. The finish grade over the trench shall be mounded to prevent formation of depression after settling. 7. Insulation shall be placed over any wastewater line or pipe over which a driveway, parking, or vehicle storage area may be constructed. 8. A minimum 2 foot of accepting soil is required below the drainfeld rock for a 5 foot wide trench. Contractor shall verify this condition prior to placement of the rock. If course gravel or other unacceptable material is encountered, the contractor shall inform the inspecting engineer for evaluation of accepting soil before placement of drainfield rock. On -Site Wastewater astewater Disposal System - Specifications. Lor Greatland Fstates # 1, Block 2, Lot 6 August 3. 2009 Page 3 of 3 MINIMUM MATERIAL SPECIFICATIONS: 1. A MOA approved septic tank manufacturer must construct any septic tank proposed for installation. 2. Insulation shall be at least 2 inch thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam III, or qual) 3. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal) 4. A permeable nontoxic geotextile silt barrier (Typar 3401, Mirafi MON, or equal) shall be installed between the final leachfield gravel layer and the native soil backfill. 5. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. 6. The following pipe materials are MOA approved for use in septic system installations: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (IIDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. INSPECTIONS: Typically there will be a minimum of 3 inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: 1. The first inspection must be conducted after the excavation of trenches and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. 2. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, cleanouts, and insulation. No backfill should be placed at the time of inspection. 3. The final inspection is to occur upon final grading of the property. The inspecting engineer is to be contacted at least 24 hours prior to the start of construction. The engineer shall be notified %2 day prior to a required inspection. Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www .ci.anchorage. . ek.us (907) 343-7904 III WNncrwY,aoeiwr Wom Stull Solis Log - Percolation Test `�..,.,,.•••'�'�;-% Performed For. _ il)(= t'✓ A/�//S nLGEn/ Data Performed:O na 1" Legal Descrip0on: 6 R c A T r ", EST. [ e * �> P/ 7 Township, Range, Section: _ T-/ 5',1/, P / V/, SEC I 0 TEST 8Ot,E # I Slope Site Plan 0R&,AN9c1 SrLT%� SNn, �y, 4- fir rlAvP c. 5- �r(,Hr-) WAS GROUNDWATER SItT% SA�rt'/ ENCOUNTERED? A/c G,r/Av5V,- )TTO�A 5 OF HOLE oLo�'75 1 16- 1 S IF YES. AT WHAT DEPTH7 L Depth to Water After D Monitoring? ),,,,p E Date: tC 7 N X09 7//40 C f��Mffj Date Gross Tune Net Time Depth to Water Net Drop 6110109 9:/0 NEVEM81 6' 3210=1 ENNEN� '���� Reading Date Gross Tune Net Time Depth to Water Net Drop 6110109 9:/0 O 6' NtKGULH nUN NATE L 1 (MmtWeah) PERC HOLE DIAMETER 6 TESTRUNBETWEEN S FT AND 6 FT COMMENTS Ser t'i" pef7p PIpr STIru VP PERFORMED BY:_ !7 L7 1 (�." n Z. ff_< CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 7 /N-65 OF -:% Municipality of Anchorage r ��•, GI RS Development Services Department Building Safety Division .�. On -Site Water and Wastewater Program • • •, • •• 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 04 / • (%j 1 www ci anchorage ak.us 9/N / P :AARON D. (907)343-7904 /��y;'• �N/CEit5M Soils Log - Percolation Test �141 Performed For. Dennis Walden Date Performed: 7� M/ u g Legal Description: Greatland Estates Unit 1, lot 6. Blk 2 71 -sr HOLE #a rr Depth 1 rot GM S1r-ry, SAA/Oy i Municipality of Anchorage Development Services Department Building Safety Division �1 On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci anchoraae.ak.us (907) 3417904 Solis Log - Percolation Test tfr:.OF.gCg1� AARON o:=GI ( Na CE11538 I'IP��-,OFESSW�= Performed For. Dennis Walden Date Performed: �/ 2 I;-'/09 Legal Description: Greatland Estates Unit 1, Lot 6, Blk 2 Township, Range, Section: T15N, Rt W, SEC 10 %EST .# r lope nat-E - 3 Slope Site Plan 21640y 5 O t_ S T/'""by CrAVEL some tog ace s gbTmm OF HGL F_ 1 15- 16- 17- 18- 19- 20 - WAS GROUND WATER ENCOUNTERED? /!O S IF YES, AT WHAT DEPTH? L Depth to Water After O P Monitoring? E Date: M'MMMMMMMMM Date Gross Time Net Time De th to Water M N t Dro IN N I u o9 1 12 U 6 Y8 2 12:N2 30 � s/16 13/)b 3 Z:y a s'h N I :lit 30 (, s/ x l� s I:) s o 6 IN5, S 3 0 1� 1rZESO AI(Wc� 14- Art, HEMEME MEN a0■N "AM �WEEN NNEENE ME 1,■■■■■■■■■ "■■■■■■■■■ Reading Date Gross Time Net Time De th to Water M N t Dro IN N I u o9 1 12 U 6 Y8 2 12:N2 30 � s/16 13/)b 3 Z:y a s'h N I :lit 30 (, s/ x l� s I:) s o 6 IN5, S 3 0 1� 1rZESO AI(Wc� 14- Art, PERCOLATION RATE Z 6 • S (mr.Ae✓roil PERC HOLE DIAMETER 6 �� TEST RUN BETWEEN b FT AND :;L FT COMMENTS 1145, 7,F4+ r<F F- , ofr.C. Tre.T, ,Ainr CoArr.VC,FN. PERFORMED BY: _At�1 I _Aaron �• SAVVIVg . CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Y Z i 09 Municipality of Anchorage Development Services Department Building Safety Division a� On -Site Water and Wastewater Program 4700 Elmore Road P.O. Boz 196650 Anchorage, AK 99507 www.ci anchoreae ak.us (907) 3417904 Soils Log - Percolation Test Performed For. Dennis Walden Legal Description: 7EST- l4CIL E Depth Grealland Estates Unit 1, Lot 6, Elk 2 #-y 1-I I ORi+Au1G5 OL 6- S/, -Ty ;VAILY &TZAVE1. 7- SOMI col3t3LES 8- �61Qrlrrmtrl.deAtl,Y� 1 ..... AZ4 ;AARON D."JARNAGIN; ' No.CE11919 'cOi:iS-Oi �. i►, 9?OFESS1ClAP+ Date Performed: Oz�Z rlb 9 Township, Range, Section: T15N, RiW, SEC 10 Si}a plan WAS GROUND WATER 9- ENCOUNTERED? S 10- IF YES, AT WHIT DEPTH? L Depth to Water ARar/� D 11- Monitoring? //OrtG E An'S 12- Date: 07/0 O¢ BoT. of Via RE 18- 19- 20- Reading Date Gross Time lMENOMM Dep h to Water et Dr 14 / INiOM►iaMa )2.'15- O t/z 11■■9■■■■N1M VA, )%2 11■■■■■■Md■ d 5�I M■■EE■,ME■, Z 5' nRN®■■Nr■■ 6 1: Sa 3 A 9/i a ■®■■n■■d■■ NFD �i-1, s H■■■r■■■■■' 1N■■■\■J■■■ 11■■■■■■■■■ ■o■■■SC■== Reading Date Gross Time Net Time Dep h to Water et Dr 14 / ZS o9 )2.'15- O t/z VA, )%2 Z:N7- d 5�I Z 5' 6 1: Sa 3 A 9/i a X Pr7E5c, NFD �i-1, s PERCOLATION RATE / 3 (�W rn) PERC HOLE DIAMETER 6 �• TEST RUN BETWEEN S. S FT AND (>. S FT COMMENTS PfrtLF J�'inc Pq 4P Fr, FO rZ wra'r Ft+ MnA'rrn RING, PERFORMED BY: ANT I AYOA 1� • �+�+a a,: ,n CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: Y 2 S O 9 GRE.' `' ANCHORAGE AREA BOF --"--,H Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 ,) INSPECTION REPORT ON-SITE SEWAGE „WAGE DISPOSAL SYSTEM �r NAME ��nn 15 WC{�G�2A MAILING ADDRESS -7 r lQDune�' !( PHONE33J3­ 05cgf�j� LOCATION) 1'f '4�Z5tPe 4L5 G&4 LEGAL DESCRIPTION Lotio AIA ��?✓��� �hCl $' /�s SEPTIC TANK: DISTANCE FROM WELL / 2�i MANUFACTURER t��� 5 ��/ MATERIAL �r e� ` COMPARTMENTS at- lcb fL7 11 INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY )Goo GALLONS. SEEPAGE PIT: NUMBER OF PITS DIAMETER OR WIDTH 4t' LENGTH �5, ' DEPTH LINING MATERIAL CRIB CRIB SIZE: DIAMETER _a�DEPTHIP DISTANCE FROM: WELL �Cl' J M�ggr TOTAL EFFECTIVE BUILDING FOUNDATION—, NEAREST LOT LINE_/_ . ABSORPTION AREA (WALL AREA) 5 7b SQ. FT. ADDITIONAL ABSORPTION WELL: nn //v i'C4 iPC� TYPE fVii6fl-e `!JV lie C1 CONSTRUCTIONGr,((� DEPTH I7S �” DISTANCE FROM: BUILDING FOUNDATION CESSPOOL LOT NEAREST LINE-, SEWER r f SEEPAGE INE SEWER LINE TANK , SYSTEM OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCES: 4 _ 15, " " c: z0'(0 INSTALLED BY: PIPE MATERIAL: I1 Cc 5,f ioon LOT SLOPE: REMARKS: 0;/ CO -171;/, 7e—, t ze,/ DIAGRAM OF SYSTEM Well IVI - VV DRILLING, Inc. P. O. Box 4-1728 n 2811 Dawson A C 907-279-1741 ANCHORAGE, ALASKA 99509 DRILLING LOG Dennie 'Walden of Well_ Jon Location (address of: Township, Range, Section, if known; or distance main BIk 2 Graat ha.ndEsstates Subdiv. Size of casing__6 Depth of Holelo5__--feet Cased to! feet Static water level 145 ft. (;M;�S�) (below) land surface. Finish of well (clieck one) open e11d Screen ( ); Perforated ( ), Describe screen or perforation____one Well pumping test at�` _gallons per (Myr) (minute) for ---I--- —hours with --100°" of drawdown from static level.--— —lt. Date of completion-,, 9-,T WELL LOG Depth in feet from ground surface Give details of formations penetrated, size of material, color and hardness _Silty Gravel:_oocaisignal_boulc>_er1_undfierentiated �q ----- ------------- - __. TO- _-<.__ Boulder Grnyolt yery_rninar_rnd•+ mstrix -------- ----- --12-TO_1Z_ n1Lgr.2v�l rin ss ---- L4,3T0 150 —1-52Z'O_-17-0..—_ '_iCdll]IILtliL'e_gLUYa1 L._'.;[0.1. rL��1a r f arayi4 Z. We brig � �. 1 — CUSTOMER n GREATER ANCHORAGE ARRA BOROUGH DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 YO ON �NitEO IEM',�O/J SEWAGE DISPOSAL SYSTEM - APPLICATION AND PERMIT NAME OF APPLICANT �/�//✓t"'"' INSTALLATION LOCATION LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK . 11-r -6 9UL I TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH SOIL TEST RESULTS COMPLETION DATE ANTICIPATED PERMIT NO. MAILING ADDRESS /9-A, bOLtl PHONE Z" SEEPAGES PIT ✓ DRAI INSTALLED BY OTHER NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK �- FOUNDATION TO SEEPAGE PIT 20 f DRAIN FIELD %i / "-3 ,.? I,! • 1 ,!t lir r SEEPAGE AREA SIZE - - ,Q /'-� TYPE SEPTIC TANK TO SEEPAGE PIT WALL -� /�/ SEPTIC TANK S, SEEPAGE PIT L DRAIN FIELD TO NEAREST LOT LINE. WELL TO SEPTIC TANK v V ` SEEPAGE PIT - DRAIN FIELD ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK DRAIN FIELD SEEPAGE PIT SEPTIC TANK, 67 , SEEPAGE PIT ( DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL DSACKFILL CONFORM TO BORO TIONS REGARDING I/STALLATION. 9 G.A.A.S. OR LICENSED DESIGNER DIAGRAM OF SYSTEM I1) THAT I AIV FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESC IB D YSTEM IS IN ACCORDANCE WITH SAID CODE. I nnT _vW APPLICANT'S SIGNATURE �'Yl .%.i c; C�/V (j✓T�� ��Y� NAME OF APPLICANT GREATER ANCHORAGE AREA BOROUGH . PERMIT NO.. DEPARTMENT OF ENVIRONMENTAL QUALITY 3330 "C" STREET ANCHORAGE, ALASKA 99503 TELEPHONE 274-4561 - - SEWAGE DISPOSAL SYSTEM APPLICATION AND PERMIT 'z LJ� MAILING ADDRESS INSTALLATION LOCATION Je LEGAL DESCRIPTION INSTALLATION OF: SEPTIC TANK I_� - SEEPAGE PIT DRAIN FIELD��/ OTHER TYPE AND SIZE OF FACILITY TO BE SERVED" FINANCED THROUGH TO BE INSTALLED BY NOTE: THIS PERMIT IS NOT VALID WITHOUT SOIL TEST SOIL TEST RESULTS COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED, BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. SEPTIC TANK SIZE TYPE MINIMUM DISTANCES, REQUIREMENTS FOUNDATION TO SEPTIC TANK SEEPAGE AREA SIZE FOUNDATION TO SEEPAGE PIT e- lQ ` . DRAIN FIELD SEPTIC TANK TO SEEPAGE PIT WALL IJ / SEPTIC TANK SEEPAGE PIT DRAIN FIELD o` TO NEAREST LOT LINE. WELL TO SEPTIC TANK / SEEPAGE PIT DRAIN FIELD l®� ALSO CONSIDER AREA WELLS. WATER MAIN TO SEPTIC TANK /o / SEEPAGE PIT �U / DRAIN FIELD 1V / SEPTIC TANK, / SEEPAGE PIT /L )/, DRAIN FIELD TO RIVER, LAKE, STREAM. CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION 5 FEET INTO UNDISTURBED SOIL. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVABLE CAPS. GRAVEL BACKFILL CONFORM TO BO ROU REGULATIONS REGARDING INSTALLATION. n0: G.A.A.B. OR LICENSED DESIGNER TYPE DIAGRAM OF SYSTEM 1 CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. DATE APPLICANT'S SIGNATURE • Municipality of AnchoragPs M On -Site Water and Wastewater Program (907) 343-7904 LEC F. CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcel I.D. 45/-/3%-/J vac' 1. GENERAL INFORMATION 2. kation (site ac Current Property Expiration Date: 3 — 19 ( If riptiontic tied �stuzo1,!^Si r.ji Z _ C J (c ; -ier(s) L cello Day phone 425)-•32"L-JS4� Mailing address Qs -s- tZyr-kZ r khe E.", e LJA 9821 ,, eJ Real Estate Agent,, O4,1'��� %�i'c wz �J a f , e �e,l� !7 r:�c/ Day phone TYPE OF DWELLING: Rr Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) COSA Fee $ CNO ,W Waiver Fee $ Date of Payment /:U A 3 Receipt Number COSA # Date of Payment Receipt Number Waiver # 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual !,Ah,;A..,I :Ar,t�r Cfnrage V i I Hnirlinn Tank Fl Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ /�� e °'A / `' c -� _: _ Date. l `31(Vf Received by: �. v� COSA to be released to the engineer, unless othervAse requested by the engineer. COSA Fee $ CNO ,W Waiver Fee $ Date of Payment /:U A 3 Receipt Number COSA # Date of Payment Receipt Number Waiver # 5 STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. 1 Name of Firm IZZ3be f- t L- l„)a-�r�o-, Phone �1C7/ Address v`lZ2 /:.� 7— C'a f✓ Engineer's Printed Name Date 'Vel -3 6. DSD SIGNATURE _ System 41 Approved for bedrooms. System #2 Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following OF i RKd. N1.-:. tisk" .� 9, - • e . ecs✓ 'tea ROSEMiA AM N •- Na. Cel #}T4 Q ®. .'v- 0 r / By: i i+y / �C'd Original Certificate Date:/ 3 The Municipality.of "Choraga Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist Septic System Advisory Well Flow Advisory COSA blue sheet 9-1-12.dac X _ Nitrate Advisory Arsenic Advisory Other If more than 1 septic system Is on the lot: . COSA Checklist # _of _ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: 6e.a+Lo. ,ol EsT ,r%5 4 6( Cfi7-(o� 1, parcelID: OS -1-131-10 A. WELL DATA Well type Fr, vate- If A, B, or C provide PWSID # Date completed ) 9 _� 3 Sanitary seal (Y/N) Y Total depth 165 ft. Cased to 16 3 ft. FROM WELL LOG Date of test 6 /1 /?_3 Static water level 14S ft, Well production .S g,p.m, WATER SAMPLE RESULTS: Well Log (Y/N) Y Wires properly protected (Y/N) XeA 1�2iIi3 Casing height (above ground) 3 O in. AT INSPECTION l l h- -b 3 l41,y ft. 6111 g.p.m. Coliform colonies/100 mL Nitrate 2.83 mg/L Arsenic VA16 ug/L Date of sample: 11/7-4/Collected by: R-06- 'f L, Wde—r_) B. SEPTIC/HOLDING TANK DATA Tank Type/Material S' -e -e.( ba 9�) Date installed Tank size I S o 0 gal. Number of Compartments .z Cleanouts (Y/N) Y Foundation cleanout (Y/N) /y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 12 %13 Pumper J fL se OCC PW �in C. ABSORPTION FIELD DATA Date installed 4 49/0 Soil rating (g.p.d./ft2 or ft2/bdrm) z System type Ska(low Ve v_ Length 116 ft. Width S 4' 1014, Zj / it. Grauel below pipe ft. Total depth a a'f.' ft. Eff. absorption area i7 90 ft2 Monitoring tube —I— Depression over field AJ Date of adequacy test N2,7/13 Results (Pass/Fail) Pa;SS For. S bedrooms Fluid depth in absorption field before test O in. Water added 4465,3 gal. New depth 8 in. Elapsed Time: 12o min. Final fluid depth S in. Absorption rate >_ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date D. LIFT STATION Date installed - "Pump on" level at Datum Size in gallons Manhole/Access (YIN) _ in. "Pump ofr level at in. High water alarm level at E. SEPARATION DISTANCES WELL ON LOT TO: Cycles tested Meets alarm & circuit requirements? Septic tank/lift station on lot ms, Absorption field on lot I 3o �-+ Public sewer main N /A Sewer /septic service line 7 2-5 ii' Animal containment areas ! S o SEPTIC/HOLDING TANK ON LOT TO: 0 Onadjacentlots 103 CE l.ok -7 On adjacent lots `Ed �o� Q✓ Public sewer manhoWcleanout Holding tank MIA Manure/animal excrete storage area, -7 100 F i Building foundation J R. S F F Property line 26 Absorption field 14S fl - Water N N /A Surface water 7 f a o Fj main �� Water service line Wells on adjacent lots0j Sof" ABSORPTION FIELD ON LOT TO: Property line Zbr� �� Building foundation /a9 I+ Water main 14A Water Service line � Surface water 7l ° 0 '�+ Driveway, parking/vehicle storage F� Curtain drain N/4 Wells on adjacent lots 13S F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and OR"�� review of Municipal records that the above systems are in = �P;�• • • • • A(�®,7�1.,+ conformance with MOA COSA guidelines in effect on this date. s Engineer's Printed Name 0 . Date 42113 lx•• ROBERT L HMO. CEI (✓ ,e COSA brown sheet_10-10-12.doc _ GR_EA T _ LAND _ _DRI N89' 55' 36"E - Ox DH/E , N89' 55' 36"E — oA/ oH/F-- GH/ 300.00, i/ orv/ OH / M�i/ 0I x WELL x X _ _ X_ _ _ _ 10' SLOPE MAINT ESMT _--_ CHAIN UNK —FENCE-1" IRON PIPE I® ti6 63 45.4' I 6'x6' CONCRETE ryb� HOUSE Q) 1 ,po Q / 100' WELL / PROTECTION I 100' WELL RADIUS O PROTECTION / I p OI RADIUS OM M 1—STORY HOUSE 3 0 x CARPORT T ¢WELL / WITH DAYLIGHT O I LOT 6 I 324 ��� BASEMENT O O GARAGE m 11 7 O I 2.07 ACRES 16, CARPORT O 1 p 13,2 x O Z Z x I x 5 x I GREA T L AND ES TA TES UNIT NO. 9 x BL OCK 2 I 0 50 FNO, YELLOW PLASTIC CAP CHAIN LINK FENCE x LS 5773 — — — — — — — — — — 10' UTILITY ESMT N89' 55' 36"E 300.00' LEGEND ALL OIMEN90NS IN FEET UNLESS OWERIAS£ NOJ£O I HEREBY CERTIFY THAT HAVE SURVEYED THE DESCRIBED PROPERTY AND NO ENCROACHMENT EXISTS EXCEPT AS INDICATED. IT IS THE PROPERTY LINE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY — — EDGE OF PA V/EMENT EASEMENTS, COVENANTS, OR RESTRICTIONS WHICH DO NOT APPEAR ON O UTILITY POLE THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES —Da/E— OVERREAD ELECTRIC SHOULD ANY DATA HEREON BE USED FOR CONSTRUCTION OF FENCE — x — FENCE LINES OR FOR ESTABLISHING BOUNDARY LINES. BUILDING WOOD DECK --'tP��....... Ar;,QSIIl1 - O --- HOUSE OVERHANG Ir SURVEY MONUMENT C9'.9 Q SEPTIC STANDPIPE EXISTING WELL ... AS-BUILT VE1 VERNON L. RO FS: GREAT LANG ESTATES UNIT N0. 1 LOT 6 BLOCK 2 PLAT 71-274, ANCHORAGE RECORDING DISTRICT Consultants III SSI0NA1 WITHIN SW 1/4, T15N, RIW, SEC 10, S.M. ALASKA P11arF: JJ]—al]o I IfJ�3 Rwrxa axm It It n"\\`����� Hoaz scut: f=5o' soavcr oes: Isrye/sou talo: MW@so ANOIORAfi. Ilt Well Flow Test Location/Legal 23716 Greatland Cir Chugiak, Alaska Well Depth (ft) 165 * from 73 well log Static Water Level (ft) 141.9 Casting Above Ground (ft) 2.5 Flow Test Date: 11/27/13 Project #: 13-004 Inspector: Robert Walden # of bedrooms: 5 Target gallons: 750 Time Water Level Vol (gal) Cumul. Vol (gal) Meter Reading (gal) Flow Comments (gpm) 8:13:00 AM 141.9 106680.2 turned water on 8:14:00 AM pump started 8:15:00 AM 6.5 8:16:00 AM 8.6 2.1 un -kinked hose better 8:18:30 AM 6.3 8:19:30 AM 2.3 6.0 adequate flow 8:20:00 AM 19.8 106700 Start test 8:21:30 AM 1.8 8:22:30 AM 144 4.1 6.1 8:29:00 AM 3.5 8:30:00 AM 9.5 6.0 8:50:00 AM 144.6 170 106870 5.67 Rate calc by meter/30 min 9:20:00 AM 144.8 361.2 107061.21 6.02 Rate calc by meter/60 min 9:50:00 AM 144.81 569.8 107250 6.33 Rate calc by meter/90 min 10:20:00 AM 733.6 107433.6 6.11 Rate calc by meter/120 min 750 Over target 150 gal/bedrm 10:50:00 AM 144.8 918.1 107618.1 6.12 Rate calc by meter/150 min 11:20:00 AM 1104.1 107804.1 6.13 Rate calc by meter/180 min 11:50:00 AM 144.8 1285.3 107985.3 6.121 Rate calc by meter/210 min 12:20:00 PM 1 1465.31 108165.3 6.11 Shut off flow test 12:30:00 PM 142.8I I JAIready recovering quickly average 6.11 ' 1 *: 491" ROBERT L. WALDEN ,,�� No.CE13874 AS -BUILT SYSTEM DETAILS/SITE PLAN PERMIT No. SW090135 GREAT LAND ESTATES #1 BLK 2 LOT 5 PID No. 050-131-10 —'� <00' WELL RADIUS PROPERTY LINE — — — _N8 ',�5�5 Iglro IZ I NORTH TRENCH I� bI o: o ®THi ®3 / TH o / G s 26.5' / / / SOUTH GREATLAND _ _ _ R/ VE _10' SLOPE MAINT ESMT OLD SEEPAGE PIT—\_I 1 ' \ INSULATION--, F NEW 1500 G, SEPTIC TANK F 3 TRENCH dl /� UANICS FLOW DIVIDER 0 L W/ CLEANOUT in NEW 5'x64' �o b \ \ HOUSE I/ b I DRAINFIELD 100WELL RADIUS zl 6 ' B -D =19.9 C -D =30.8 C -E =38.6 B-E =19.5 A -F =66.8 B -F =75.9 A -G =109.2 B -G =142.3 A -H =120.3 B-H =149.5 A -J =135.9 B -J =172.9 A -K =168.3 B -K =206.6 A -L =160.8 B -L =201.7 0 U TH4 ­ L - 0 1 T n61 u~i 101.5 N � o I%%ROBERT L WALDEN I��iE • _ No. CE13874 .'_;�; ... %.. 1500 GAL SEPTIC TANK (STEEL -1090) (�TBM: GARAGE FLOOR �ELEV 103.38 y / N fYY 6 GARAGE 0 � MnpT To pw � O VARIES SOUTH TRENCH 2.9 n In .^FINAL GRADE In In 3.0 SCALE: 4. .S. I II II ,--nLTER FABRIC II III 1 VARIES LEGEND • CLEANOUT O MONITOR TUBE WELL ® TEST HOLE BENCH MARK BOH = BOTTOM OF TESTHOLE CO = CLEANOUT MT = MONITORING TUBE SEWER ROCK SCALE: N.T.S. NO k�oV)�.sl L 4S—BUILT SYSTEM DETAILS / SITE PLAN GREAT LAND ESTATES UNIT NO. 1 LOT 6 BLOCK 2 715NRlW SEC 10 xuc-r•w D.M. roh/sr an0. nmma Pg 2 OF 2 L 4.10'