Municipality of Anchorage
On -Site Water and Wastewater Section • (907) 343-7904 Page of
ON -SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP 221204 PID Number: 01707371000
Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ D Duplex p ( ) ❑Two Single Family Project: New NO Upgrade
Name
TUTTLE ABSORPTION FIELD
Site Address ❑ Deep Trench ❑ Wide Trench El Bed ❑ Mound
8020 COX DRIVE ❑ Other
Phone Number of Bedrooms Soil Rating Total depth from original grade
4 6* GPD/SF 1.26,-1.0 (VARIES) Ft.
LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe
Subdivision Block Lot 0.66,-1.6 (VARIES) Ft. 0.5,0.6
GRECIAN HILLS BLOCK 2 LOT 6 Ft.
Fill added above original grade Gravel length
Township Range Section 4.1,1.84 VARIES Ft. 110 Ft.
Gravel width Beds: Number of Lines Distance between lines
SEPARATION DISTANCES 5 Ft_ NA NA Ft.
To Septic Absorption Lift Station
Tank Field n Holding Sewer Total absorption area Number of trenches Dist. between trenches
From Tank Line 114 Ft2 2 10
Ft.
Well +100 +100 - _ +75 TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other
Manufacturer Capacity
Surface Water +100 +100 — _ ORENCO 1500 Gal.
Material Number of compartments
Lot Line +1 0 +10 - - NA DCPD 2
Foundation NA I NA _ _ LIFT STATION
Manufacturer Capacity
Remarks TOPSOIL AND SEED ADDED 2023 — _ Gal.
* SEE LETTER Alarm location Electrical installed by
PIPE MATERIAL House to tank 3034 Tank to 3034
Installer drainfield
GUARANTEED SVCS Drainfield 3034 CO/MT3034
Inspector C.BALZARINI BENCH MARK (Assumed elevation) 100.86 ft
Inspection 1st 10/�/22 2�d 10/12/22 Location and description
dates: ;EVAZ7 EX POD L I D
3`d 10/15/� 41h 10/20/26
ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp
Conditional Approval: Date ����'� . • :9s����
Septic System CHARLES G BALZARIU
Approved Date / 5Z ����`�;•,. CE-13854
Note: this approval oes not include well permit requirem nts. �� FOPROF*
(Rev 05/02/18)
7/30/9. ROFESSI0N�.4
C&M ENGINEERING SERVICES
Ph: 907-854-5558
Municipality of Anchorage
Onsite Water & Wastewater Program
4700 Elmore Rd Anchorage, Ak 99507
RE: Grecian Hills Block 2 Lot 6
Dear Reviewer,
This letter is in regards to the inspection report for the subject property.
A 6.0 application rate is used for the organic topsoil layer, perc’d by GEG at TH#1 for the side wall of the
sand. The effective absorption area is 2(55’+5’+55’+5’)*0.5’ – (6’+6’+5’)*0.5 = 114 sqft. This is the
nominal effective minus the area discounted during construction.
For a 4 bedroom home at an application rate of 6.0, the required absorption area would be 100 sqft.
There is approximately 550 sqft of absorption area on the bottom of the trench which is not considered.
The soil at the bottom of the sand layer has an application rate of 1.0 based on the perc rate of 69 mpi at
C&M TH-1.
Sincerely,
Charles Balzarini, PE
3/15/24
99.7 BOTTOM OF PIPE
99.7
98.7
96.4 96.36
BOH
-DRY
FINISHED
GRADE
96.27 BOTTOM OF SAND
ORENCO MEANDER/
FAP 2.0
SCHEMATIC PROFILE VIEW SHOWS ELEVATIONS OF INSPECTED
ELEMENTS BUT DOES NOT DEPICT SYSTEM IN ITS ENTIRETY.
INSPECTION FOR GENERAL CONFORMANCE TO DESIGN AND MOA
REQUIREMENTS ONLY.
100.86 BM100.7
POD
99.1 BOTTOM ROCK
100.36, OG
102.2
TH
CM
99.2
6'
EFFECTIVE TOPSOIL
BAND
4" INSUL AND
FILTER FABRIC
99.5 BOTTOM OF PIPE
99.7
94.9
FINISHED
GRADE
94.9 BOTTOM OF SAND
98.9 BOTTOM ROCK
102
98.9
4" INSUL AND
FILTER FABRIC
97.9, OG96.9
GEG
TH2
90.86
BOH
WL 94.36
5/20/22
EFFECTIVE TOPSOIL
BAND
97.0
UPPER TRENCH
LOWER TRENCH
92.0
MOUND SLOPES ARE 3:1,TOPSOIL AND SEEDED.
CHARLES G BALZARINI
CE-13854R
E
GISTEREDPROFE S S I O N A L E N G I
NEERC&M ENGINEERING SERVICES
907-854-5558
SEPTIC RECORD DRAWING
OWNER:TUTTLE DATE:3/13/24 REV:DRAWN: CB REF:
SCHEMATIC ELEVATION - SCALE: NTS
3/13/24
LEGAL DESCRIPTION: GRECIAN HILLS B2 L6
4 BR
HOME
1500 GAL
ADVANTEX W/AX-20
POD FAP 2.0
W/ORENCO
MEANDER TANK
SPLITTER, TYP
NOTE:
PIPE SHOWN
SCHEMATICALLY
DOUBLE CO
5'X55' SHALLOW
TRENCHES
UTILITY EASEMENT
A
B
C D
E
F
G H
I
J
K L
M
NOTE:
THE ORIGINAL DESIGN INCLUDES A DISCLAIMER THAT THIS SYSTEM
MAY NOT FUNCTION CORRECTLY AND A HOLDING TANK MAY BE REQUIRED
THE PLUMBING FEEDING THE FIELDS IS UNIQUE IN ORDER TO MEET
THE MAXIMUM 20' SEGMENT LENGTH FOR GRAVITY AWWTS SYSTEMS
WITH REDUCED SEPARATION TO GROUNDWATER.
THIS SYSTEM IS CONSTRUCTED IN WET, FROST SUSCEPTIBLE, AND
EXPANSIVE SOILS. THIS MAY RESULT IN DIFFERENTIAL SETTLEMENT.
THE SYSTEM IS INSULATED WITH MINIMAL SOIL COVER.
CHARLES G BALZARINI
CE-13854R
E
G
ISTEREDPROFE S S I O N A L E N GINEER
C&M ENGINEERING SERVICES
907-854-5558
SEPTIC RECORD DRAWING
OWNER:TUTTLE DATE:7/22/23 REV:DRAWN: CB REF:
PLAN - SCALE: 1" = 20'
3/8/24
LEGAL DESCRIPTION: GRECIAN HILLS B2 L6
COX DRl VE
001
lL
SURVEY ORDERED BY:
dine white
AI R4 FHA Fd ^ w R7 9n
N 89 55' 54" W 87.20
so
9
THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY
CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS
NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELI NES.
EASEMENTS OF RECORD,OR ANY LEGAL ENTITY, OTHER THAN THOSE APPEARING ON THE RECORD PLAT
ARE NOT SHOWN HEREON( UNLESS INDICATED)
NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE
PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS.
ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE.
OF A
.C.D.. 49 TH*
SHANE A. HOLT
�O P Q4 ."LS-6914 -- -- oa o
fessiana�
AS-BUILTSURVEY I" = 30"
NO CORNERS SET THIS DATE
I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY
OF THE FOLLOWING DESCRIBED PROPERTY
LOT6 BLOCK2 GRECIANHILLS
ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE
VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN
THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS
EXIST OTHER THAN NOTED.
DATED AT ANCHORAGE,ALASKA THIS 16 TH DAY OF
NOVEMBER , 2022
HOL T LAND SURVEYING
THESURVEYDATA ON THIS DRAWINGIS PREPARED FOR THE OWNfR OFRECORD ONL Y 9309 GROI/ER DRLI/E
ANYCOPYING, OR UTILIZING THE DATA HEREON IS PROH181TED UNDER COPYRIGHT LAW ANCHOR4CE.AK 99507
2326 FB 221-38 229-30 223-8515
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-790,4 Fax: (907) 343-7997
http://wvm.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP221204
Work Type: Septic Upgrade
Tax Code Number: 01707371000
Site Legal Address: GRECIAN HILLS BLK 2 LT 6 G:2940
Site Mailing Address: 8020 COX DR, Anchorage
Owner: TUTTLE BETTY ANNE .
Design Engineer: GARNESS ENGINEERING GROUP LTD
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft:
Total Bedrooms
6/29/2022
6/29/2023
15260
Z Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
�C) .4' ( Nec"��n9 t'nee r, G �' ,
Ctnj C►'laY9 _tb /)Orf -b �—'►'eld.
Received .�
Issued By: y
G 6V10e J -to /4G va✓I l e x
Date: u 2_
Date:11
ZG1 ZZ
a
ON-SITE SEPTICMELL PERMIT APPLICATION
Parcel I.D. 017-073-71
Property owner(s) BETTY WHITE C/O DION WHITE
Mailing address
Site address 8020 COX DRIVE *ANCHORAGE, AK
Day phone 907-441-7542
Legal description (Sub'd., Block & Lot) GRECIAN HILLS; BLOCK 2, LOT 6
Legal description (Township, Range & Section)
Lot Size Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(Z all that apply)
Absorption Field
nx
Initial ❑
Single Family (SF)
(w/wo ADU)
Septic Tank
nx
Upgrade Fx]
Duplex (D) ❑
Holding Tank
E]
Renewal❑
Multiple Dwellings El
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
❑
THIS APPLICATION
INCLUDES A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: A 5 � 5 Waiver Fees:
Date of Payment: _ f 111) � Date of Payment:
Receipt Number: — 0 5 $1 L16 Receipt Number:
Permit No. 0 S P�A 1109 Waiver No.
GADevelopment Services\Building SafetyNOn Site Water and WastewatefformsUient Forms\Permit Application.doc
C&M ENGINEERING SERVICES
Ph: 907-854-5558
Municipality of Anchorage
Onsite Water & Wastewater Program
4700 Elmore Rd Anchorage, Ak 99507
RE: Proposed Septic System for Grecian Hills Block 2 Lot 6
Dear Reviewer,
Prior to our planned inspection, we were notified of several issues with the septic installation at the above
referenced property.
The excavation was not opened and closed in the same day. While this is not in violation of the permit
requirements, we have re -iterated to the installer that the excavation needs to be opened and closed in
the same day or covered and heated during freezing conditions after OCTOBER 151h
Concerns were raised regarding the placement of filter sand per plan. The filter sand was installed in the
upper trench as shown in the attached profile views.
We also note that a function of the sand appears to have been to provide additional treatment for the
originally designed CAT II treatment system to treat the effluent quality similar to a CAT III system.
It was not our intent for the drain field design to be changed, however the CAT III system already
produces higher quality effluent, so the additional filtration is not needed.
During inspection, we verified the excavation depth was up to 4' at the deepest point and as shallow as
2.5'. The max excavation depth was supposed to be 3', but the placement of additional sand at the deep
(over -excavated) end of the trench mitigates concerns with over -excavation.
During inspection of the installed distribution pipe, we observed that the invert of the pipe to be as shown
on the profile drawings. This results in approximately 6' of the length of trench on the East end being
ineffective because it was installed too deep into the topsoil layer. We are proposing to discount that
absorption area and the area on the east end wall of the trench: (2x6' x 1' + 5'X1' = 22 sqft) Subtracting
22 sqft from the apparent 220 sqft of trench as designed, leaves well above the 100 sqft required. Note
that the entire upper trench could be discounted as the lower trench would have 110 sqft of absorption
area, still meeting the minimum requirements for the system.
We perc'd a ML layer at the upper trench to confirm permeability. The percolation rate was 69 minutes
per inch. This area will effectively convey effluent horizontally and vertically; however that is not currently
considered in the design. The application rate for these soils would be 1.0. By inspection, the upper
trench (as constructed) effectively has more absorption area than accounted for in the design.
The attached soils log shows the location of TH — CM, TH-CM2 and the perc pit. Soils were only logged
at TH-CM. TH-CM2 and the perc pit revealed matching soil conditions. Groundwater was not encountered
in any of the holes. The soils in the perc pit were very wet. A traditional pre-soak was not performed
because the soils were effectively pre-soaked naturally.
We note that the ML layer was gray and is visually similar to CL. Close observation revealed the
presence of mostly fine silts and sands with some apparent clay particles.
The excavation of TH-CM shows that the west end of the upper field is more than 3 -feet above any
impermeable layer as required.
Groundwater monitoring in GEG Th -1 and the dry hole at Th -CM and Th -CM2 confirm that the upper
trench meets groundwater separation distance requirements. The GEG perc pit apparently had water and
pea gravel in it. These conditions were not replicated at the two closer testholes we excavated. The
department raised concern that the upper field may encroach on the groundwater table. The required
separation distance is 2 -feet. Based on the 2' water depth in the GEG perc pit near the west end of the
trench, there is 2 -feet separation between bottom of sewer rock and the highest observed groundwater
table.
Our inspection of bottom of trench on 10/12/22 revealed DRY soils consistent with the soil log for TH-1.
The ML layer observed was visually better than expected and contained some coarse sand in addition to
the silt/clay sized particles. Groundwater was at a depth of approximately 5.5 -feet. The groundwater tube
was removed in accordance with code requirements.
After discussions with the department, it was determined that the upper trench was required to have
segment lengths of 20 -feet or less. The distribution pipe on the upper trench was redone per plan.
Additional notes:
• The side slopes are to be 3:1 max for both trenches.
• The Contractor verified that they filled the existing trench with sand as required.
• The calculations attached to the MOA approval documents for the tank configuration indicate a
factor of safety of 2.2 against flotation on an empty tank with water at the ground surface without
the addition of supplemental ballast. These tanks have flanges to help prevent flotation.
We are requesting a change order for the upper trench as -installed. We are not requesting a change
order for the lower trench at this time.
Thank you for your time in reviewing this change order request. Please do not hesitate to contact me at
907-854-5558 or by email cgbalzarini(o-),gmail.com with any questions or concerns.
Sincerely,
Charles Balzarini, PE
10/13/22
Revised 10/17/22, 10/18/22
10/25/22
Ik
oe
CHARLES G BALZARINI`
CE 13854 4w�i
AWA-
���� FESStON'�?�.�'�'
09
GREC1AN
HILL
PRORLE
BLOCK 2 I.OT n WEST END
OTTOM OF PIPE
DP OF SAND
'IG. GRADE
F WITHIN
>F- GEG
PIT
AT GEG
'ENCH
�c� °F A�gslll
49 RL
�CHARLES G BALZARINI
+ �F`••. CE -13854 •'`��
iliF�PROFE5S10NP�-�
ORIG. GRADE
BOTTOM OF
TOP OF SAN
BOTTOM OF
9 OF Al.
5 —6 1/2 LENGTH ���P�.
WHERE ABSORPTION ,"
oe S REDUCED CHARLES G BALZARII� .
r
GRECIAN
PRORLE
HLLS
BLOCK 2
LOT 6
EAST END
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Section
a� 4700 Elmore St.
P.O. Box 196650 Anchorage, AK 99519-6650
WwW.muni.org/onsite
(907) 343-7904
I R'y�S
• a 9
�r49• e
®•eee eseeeo• ••• o•eee
® •.•®•e..eess o••
0 arles G. BAllI I ;
®®`��%�'• CE • 13834 -4
Soils Log - Percolation Test ®a`�'fi•'°•{Q(4 �i��'�
Performed For: l t` �-�A� 1 C GC S i L 6 Da t P rf d 1l 114&
e e orme .
Legal Description: 2;4. Township, Range, Section:
Slone
1 �- Gdvl
1- r--� 1 Z9 -t-,5 nz-
2-
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
20 -
COMMENTS
—7 "
WAS GROUND WATER
Depth te�
ENCOUNTERED?
(Vv
IF YES, AT WHAT DEPTH?
S
r
Depth to Water After
O
Monitoring?
N P
E
Date:
—A/4--
Site Plan
NDateG
U2/7
Net Time
30
Depth te�
Net Drop
7
PERCOLATION RATE tminutesfinch) PERC HOLE DIAMETER
TEST RUN BETWEEN FT AND 2.� _-
--s�— ---�L_ FT
Ow
PERFORMED BY: rZoQf��>yL
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DAITE.THDATE:IS ill%WAS
�—
®®®E OF_ , Go-i;z f
Municipality of Anchorage••,tJGINEERs r ••s��,
Development Services Department 4
On -Site Water and Wastewater Section p� "'••••
•*
4700 Elmore St. • '•'•••• ...
P.O. Box 196650 Anchorage, AK 99519-6650 S �9•••.'••••••••......
m :Charles l Ba1zer1
n! ; ., Q
www.muni.org/onsite 00. .
(907) 343-7904 ®J' •• CE. j s 4�iw
.°� Air.
®�®�opgr.ft
�
Soils Log - Percolation Test e o °�ss►o ice.
Performed For: wP17-C— Date Performed:
Legal Description: PFcxAy /,q -t (5 s2 1,6 Township, Range, Section:
`T �[ - C wl a.
Depth
2-
3-
A
4-
5- H
7-
8-
9-
10-
11-
12-
13-
14-
15-
16-
17-
18
19-
20 -
WAS GROUND WATER
ENCOUNTERED?
S
IF YES, AT WHAT DEPTH?
L
Depth to Water After
0
P
Monitoring?
E
Date:
Site Plan
NONE
Reading Date Gross Time Net Time Depth to Water Net Drop
PERCOLATION RATE (mmuleshnch)
TEST RUN BETWEEN FT AND _
COMMENTS '50,T 4-5 �-Ze �77tM {714(- L -,q R—
Com.
�j o4�t/t'S c✓ t`_ �l Sd�t G Etf t}�D LA?CtER
A.10 6 TF
PERFORMED BY:
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL G B N
PERC HOLE DIAMETER
FT
ERTIFY THAT THIS TEST WAS
EFFECT ON THIS DATE. DATE: et(g" 2
ION0NM%0�n
MENUMMEMEM
ON
MWEEMEM
EMEMEMEMEM
NEEMMEM
ENEEMEEMME
ENEEMMEMMMI
Reading Date Gross Time Net Time Depth to Water Net Drop
PERCOLATION RATE (mmuleshnch)
TEST RUN BETWEEN FT AND _
COMMENTS '50,T 4-5 �-Ze �77tM {714(- L -,q R—
Com.
�j o4�t/t'S c✓ t`_ �l Sd�t G Etf t}�D LA?CtER
A.10 6 TF
PERFORMED BY:
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL G B N
PERC HOLE DIAMETER
FT
ERTIFY THAT THIS TEST WAS
EFFECT ON THIS DATE. DATE: et(g" 2
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221204, Deb Wockenfuss, 06/29/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221204, Deb Wockenfuss, 06/29/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221204, Deb Wockenfuss, 06/29/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221204, Deb Wockenfuss, 06/29/22
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP221204, Deb Wockenfuss, 06/29/22
COX DRI VE
A/ R9 55' SQ" W R7 2/1
N8955'54"W87.20
SURVEY ORDERED BY:
diose WNLe
THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SNOW ANY
CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES ANDlOR EASEMENTS; AND IS
NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES.
EASEMENTS OF RECORD, OR ANY LEGAL ENTITY, OTHER THAN THOSE APPEARING ON THE RECORD PLAT
ARE NOT SHOWN HEREON( UNLESS INDICATED)
NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE
PROPERTY LINES OR POSITION ADDITIONALIMPROVEMENTS.
ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE.
THE SURVEYDATA ON THIS DRAW/NGISPREPARED FOR THEOWNER OFRECORD ONLY.
ANYCOPKA4G; OR UTILI27NG THE DATA HEREON IS PROHLB/TED UNDER COPYRIGHT LAW
-OF
Arq�;4p
x:"49 TH*y6
SHANE A. HOLT �0 a
�p LS -6914
AS�BU/LT SURVEY I" =301
NO CORNERS SET THIS DATE
I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY
OF THE FOLLOWING DESCRIBED PROPERTY
LOT6 BLOCK2 GREC/ANHILLS
ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE
VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN
THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS
EXIST OTHER THAN NOTED.
DATED AT ANCHORAGE,ALASKA THIS 8 TH DAY OF
APRIL . 2022
2326 F8221-38
HOL T LAND SURVEI7NG
9309 GROVER DRIVE
ANCHORAGZAK 99507
223-8615
i.,.IEi!...L.L. OG;E; I:::II:~:E: [;i:Ei:[;]Uilli:;i:t!E[)F:Ib~E:, I'"JLJE;T E:Eil i~:E'1"UI:;::F,IEE:, TO
Ed::: q"F.iE!i i.,.!E::L.L.
E!:F:'i!i::C: ]i F:' ;[ CI::FT' :[ [3N:!i!; F:li'dE:, E:ii3I'.,!!!~'I"Fi:UE;T:tlOI",~
]I hi~i~; "F F:ij. L.. i::t 'F ]I Ci
F~:'T,hiEFd'T i.,.I~[TH;[hl ~i:::O
Ill] ~[ ~",l:i!i;I...ll:~:E
% ]: C:i i'.,! E [::,
3" 0 i"1
Septe..~ber 23, 1977
Tom Turtle
Star Route A Box 406A
Anchorage, Alaska 9950~
Subject~ Permit Expiration
Dear Mr. Tuttle~
A permit issued by this department for well and/or on-site
sewer installation on Lot 6 Block 2 Grecian Hills Subdivision
has expired since ~2~e issue dat~ exceeds one (1) year.
In the event you still plan to install the well and/or on-site
sewer syst~a, a new permit is required. The original soil
test may be used to obtain a current per~.~it.
If the well has been drilled, a well log should be Lent to
this department to document the installation date.
If you have any questions regarding the above matter, please
dO not hesitate to contact this office immediately at 264-4720.
Sincerely,
Robert C. Pratt,
Sanitarian
MUNICIPALITY OF ANCHORAGE
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and
entered into as of this ZgTK Day of_gt �-RY _ of 20�, by and between
JANEP NZAK , herein the "OWNER," and the Municipality of
Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code
(AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this
Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),
described as —A pv.4pTIX
located at (legal description)
A Et�,c.,S BLk 2 LoT 6
2. Maintenance, Revairs and Alterations.
(Owner is required to read, understand and initial each section)
�� Throughout the term of this Agreement, the Owner shall enter into a service agreement
with an AWWTS service and maintenance provider approved by the Municipality or the
manufacturer's representative. The AWWTS shall be maintained in a satisfactory
condition capable of performing as designed and producing treated septic effluent in
accordance with the equipment's approval for operation in the Municipality.
It shall be the responsibility of the Owner during the term of this Agreement to pay for all
repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This
includes an annual maintenance fee (typically $400 to $600).
Owner agrees that only maintenance and repair personnel approved by the Municipality
or the manufacturer's representative will inspect and make any necessary maintenance,
repairs or permitted alterations to the system.
Owner acknowledges that regular maintenance of an AWWTS reduces the potential
failure of the system, which could include sewage backup and costly repairs or drainfield
replacement.
(rev. 05/18/2018) Page 1 of 3
.� Owner acknowledges that the Municipality may request records of maintenance and
repairs from the manufacturer's representative or maintenance provider.
Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be
assessed in accordance with AMC 14.60.030.
I—P Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS. The Municipality will give at least 24-hour notice.
Owner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On -Site Systems Approval.
Owner agrees that the AWWTS installation and maintenance requirements as provided
by the AWWTS vendor/installer and approved by the Municipality are the governing
guidelines for the construction, maintenance and repair of the Owner's AWWTS.
J Owner agrees to maintain remote monitoring of the AWWTS as required by the
AWWTS approval.
3. Term. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer of title, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this
Agreement shall in no way constitute a waiver of the provisions, nor in any way affect
the validity of the Agreement or any part hereof, or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void.
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the
parties under this Agreement.
7. Severability. Any provisions of this Agreement decreed invalid by a court of competent
jurisdiction shall not invalidate the remaining provisions of the Agreement.
(rev. 05/18/2018) Page 2 of 3
OWNER:
By: (signature) Date: 247 FICS'-4OZY
4RX AffM S ({print name)
STATE OF ALASKA
) ss.
THIRD JUDICIAL DISTRICT )
The foregoing instrument was acknowledged before
20at , by c crept jr� 1�
NOTARY PUBLIC FOR ALASI A
My Commission expires: S- � -a-o7-14
MUNICIPA16ITY:
By: (signature)
0.. 1.-,r5 (print name)
me thiso?9day of Trbrwa.rj
STATE OF ALASKA
NOTARY PUBLIC
jenie R. Sta. Maria 0
A,.yCOMMJSS1 metres 2-Z02V
Date: _1// S 2,0 2
Title: C 1C ,
(rev. 05/18/2018)
Page 3 of 3
Certificate of On -Site Systems Approval
Parcel I.D. 017-073-71
Legal description GRECIAN HILLS BLK 2 LT 6
Site address 8020 COX DR Anchorage AK 99516
Current property owner(s) White/ Tuttle
Expiration Date: Z "�
X The On -site system(s) is/are approved for 4 bedrooms
Conditional approval for bedrooms, with the following stipulations:
Comments or advisories:
Original Certificate Date: 3/15/2024
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory X
Tank Age Advisory Arsenic Advisory
Other
COSA Approval_June 2022
N/IJ U H M P AC! ll IJ O /` N C O l G,AG E
Development Services Department
On -Site Water R. Wastewater Section
Phone: 907-343-7904
Fax: 907-343-7997
Certificate of On -Site Systems Approval Application Z
1. GENERAL INFORMATION CC
Parcel I.D. 01707371000
Complete legal description
GRECIAN HILLS BLOCK 2 LOT 6
Location (site address) 8020 COX DR
Current property owner(s) WHITE
2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS
Day phone
3. TYPE OF WATER SUPPLY: ❑® Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ❑® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑ Steel ❑® Plastic ❑ Concrete ❑ Fiberglass
Age 1 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑® AWWTS ❑ Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑®
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On -site staff
to verify the accuracy of the information provided.
COSA Fee $ Z 0 Waiver Fee $
Date of Payment �r Z Z� —, 2-3 Date of Payment
COSA # (� S C Z 3 1 31 / Waiver #
COSA Application —June 2022
COSA Checklist_June 2022
COSA Checklist
Legal Description: Parcel ID:
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled Total depth ft
Cased to ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) in.
Date of flow test for COSA
Static water level at beginning of test ft.
Well production at time of test gpm
Water storage tank volume gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by
Date
Comments __________________________________________________________________________________
B. TANK DATA
Measured operating fluid level in septic tank
Date of pumping
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station years
Lift station material
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed)
ALL standpipes present per record drawing
Total measured depth from grade ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes go to bottom of effective.
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months)
If yes, enter date
Adequacy test date
Results Pass
Fluid depth prior to test in
Water added gal
New fluid depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
FIELD STATUS – POST RECOVERY
Effective depth (per record drawings) in
Effective depth used in
Effective depth remaining in
Comments/Deficiencies:
COSA Checklist_June 2022
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F.ENGINEER’S COMMENTS
G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Phone
Engineer’s Printed Name Date
C&M ENGINEERING
CHARLES BALZARINI, PE 3/10/24
T"itrate Advisory
Certificate of On -Site Systems Approval # OSC231311
Subdivision: GRECIAN HILLS, Block: 2, Lot: 6
A water sample revealed a nitrate concentration of 5.41 milligrams per liter (mg/Q.
The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. Since nitrates are known to slowly increase, we recommend
you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for
important information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
From Northern Testing Laboratories, Inc.
Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate
is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells.
SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of
ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the
oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners,
food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil.
TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is
associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of
young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood
stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry
oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the
concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered
from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization.
TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home
water treatment systems such as softening or iron filtration does not readily remove nitrate. The best
method for limiting nitrate in well water is source control. This can include avoiding overdosing of
fertilizer near the well and maintaining good separation distances between septic tank leach fields and
the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged
ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate.
TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a
spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect
the activity of nitrate in water. This laboratory uses several different wet chemical methods approved
under the public water supply laboratory certification program. They also have test kits available, which
the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can
monitor the change in nitrate levels from their well. They recommend comparing the test kit results
against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend
using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.