HomeMy WebLinkAboutGRECIAN HILLS BLK 2 LT 6 017 07., 71 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page of ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP 221204 PID Number: 01707371000 Dwelling: ❑ Single Family (SF) ❑ with ADU ❑ D Duplex p ( ) ❑Two Single Family Project: New NO Upgrade Name TUTTLE ABSORPTION FIELD Site Address ❑ Deep Trench ❑ Wide Trench El Bed ❑ Mound 8020 COX DRIVE ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 4 6* GPD/SF 1.26,-1.0 (VARIES) Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 0.66,-1.6 (VARIES) Ft. 0.5,0.6 GRECIAN HILLS BLOCK 2 LOT 6 Ft. Fill added above original grade Gravel length Township Range Section 4.1,1.84 VARIES Ft. 110 Ft. Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES 5 Ft_ NA NA Ft. To Septic Absorption Lift Station Tank Field n Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Line 114 Ft2 2 10 Ft. Well +100 +100 - _ +75 TANK 9 Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Surface Water +100 +100 — _ ORENCO 1500 Gal. Material Number of compartments Lot Line +1 0 +10 - - NA DCPD 2 Foundation NA I NA _ _ LIFT STATION Manufacturer Capacity Remarks TOPSOIL AND SEED ADDED 2023 — _ Gal. * SEE LETTER Alarm location Electrical installed by PIPE MATERIAL House to tank 3034 Tank to 3034 Installer drainfield GUARANTEED SVCS Drainfield 3034 CO/MT3034 Inspector C.BALZARINI BENCH MARK (Assumed elevation) 100.86 ft Inspection 1st 10/�/22 2�d 10/12/22 Location and description dates: ;EVAZ7 EX POD L I D 3`d 10/15/� 41h 10/20/26 ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date ����'� . • :9s���� Septic System CHARLES G BALZARIU Approved Date / 5Z ����`�;•,. CE-13854 Note: this approval oes not include well permit requirem nts. �� FOPROF* (Rev 05/02/18) 7/30/9. ROFESSI0N�.4 C&M ENGINEERING SERVICES Ph: 907-854-5558 Municipality of Anchorage Onsite Water & Wastewater Program 4700 Elmore Rd Anchorage, Ak 99507 RE: Grecian Hills Block 2 Lot 6 Dear Reviewer, This letter is in regards to the inspection report for the subject property. A 6.0 application rate is used for the organic topsoil layer, perc’d by GEG at TH#1 for the side wall of the sand. The effective absorption area is 2(55’+5’+55’+5’)*0.5’ – (6’+6’+5’)*0.5 = 114 sqft. This is the nominal effective minus the area discounted during construction. For a 4 bedroom home at an application rate of 6.0, the required absorption area would be 100 sqft. There is approximately 550 sqft of absorption area on the bottom of the trench which is not considered. The soil at the bottom of the sand layer has an application rate of 1.0 based on the perc rate of 69 mpi at C&M TH-1. Sincerely, Charles Balzarini, PE 3/15/24 99.7 BOTTOM OF PIPE 99.7 98.7 96.4 96.36 BOH -DRY FINISHED GRADE 96.27 BOTTOM OF SAND ORENCO MEANDER/ FAP 2.0 SCHEMATIC PROFILE VIEW SHOWS ELEVATIONS OF INSPECTED ELEMENTS BUT DOES NOT DEPICT SYSTEM IN ITS ENTIRETY. INSPECTION FOR GENERAL CONFORMANCE TO DESIGN AND MOA REQUIREMENTS ONLY. 100.86 BM100.7 POD 99.1 BOTTOM ROCK 100.36, OG 102.2 TH CM 99.2 6' EFFECTIVE TOPSOIL BAND 4" INSUL AND FILTER FABRIC 99.5 BOTTOM OF PIPE 99.7 94.9 FINISHED GRADE 94.9 BOTTOM OF SAND 98.9 BOTTOM ROCK 102 98.9 4" INSUL AND FILTER FABRIC 97.9, OG96.9 GEG TH2 90.86 BOH WL 94.36 5/20/22 EFFECTIVE TOPSOIL BAND 97.0 UPPER TRENCH LOWER TRENCH 92.0 MOUND SLOPES ARE 3:1,TOPSOIL AND SEEDED. CHARLES G BALZARINI CE-13854R E GISTEREDPROFE S S I O N A L E N G I NEERC&M ENGINEERING SERVICES 907-854-5558 SEPTIC RECORD DRAWING OWNER:TUTTLE DATE:3/13/24 REV:DRAWN: CB REF: SCHEMATIC ELEVATION - SCALE: NTS 3/13/24 LEGAL DESCRIPTION: GRECIAN HILLS B2 L6 4 BR HOME 1500 GAL ADVANTEX W/AX-20 POD FAP 2.0 W/ORENCO MEANDER TANK SPLITTER, TYP NOTE: PIPE SHOWN SCHEMATICALLY DOUBLE CO 5'X55' SHALLOW TRENCHES UTILITY EASEMENT A B C D E F G H I J K L M NOTE: THE ORIGINAL DESIGN INCLUDES A DISCLAIMER THAT THIS SYSTEM MAY NOT FUNCTION CORRECTLY AND A HOLDING TANK MAY BE REQUIRED THE PLUMBING FEEDING THE FIELDS IS UNIQUE IN ORDER TO MEET THE MAXIMUM 20' SEGMENT LENGTH FOR GRAVITY AWWTS SYSTEMS WITH REDUCED SEPARATION TO GROUNDWATER. THIS SYSTEM IS CONSTRUCTED IN WET, FROST SUSCEPTIBLE, AND EXPANSIVE SOILS. THIS MAY RESULT IN DIFFERENTIAL SETTLEMENT. THE SYSTEM IS INSULATED WITH MINIMAL SOIL COVER. CHARLES G BALZARINI CE-13854R E G ISTEREDPROFE S S I O N A L E N GINEER C&M ENGINEERING SERVICES 907-854-5558 SEPTIC RECORD DRAWING OWNER:TUTTLE DATE:7/22/23 REV:DRAWN: CB REF: PLAN - SCALE: 1" = 20' 3/8/24 LEGAL DESCRIPTION: GRECIAN HILLS B2 L6 COX DRl VE 001 lL SURVEY ORDERED BY: dine white AI R4 FHA Fd ^ w R7 9n N 89 55' 54" W 87.20 so 9 THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES AND/OR EASEMENTS; AND IS NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELI NES. EASEMENTS OF RECORD,OR ANY LEGAL ENTITY, OTHER THAN THOSE APPEARING ON THE RECORD PLAT ARE NOT SHOWN HEREON( UNLESS INDICATED) NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE PROPERTY LINES OR POSITION ADDITIONAL IMPROVEMENTS. ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. OF A .C.D.. 49 TH* SHANE A. HOLT �O P Q4 ."LS-6914 -- -- oa o fessiana� AS-BUILTSURVEY I" = 30" NO CORNERS SET THIS DATE I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT6 BLOCK2 GRECIANHILLS ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST OTHER THAN NOTED. DATED AT ANCHORAGE,ALASKA THIS 16 TH DAY OF NOVEMBER , 2022 HOL T LAND SURVEYING THESURVEYDATA ON THIS DRAWINGIS PREPARED FOR THE OWNfR OFRECORD ONL Y 9309 GROI/ER DRLI/E ANYCOPYING, OR UTILIZING THE DATA HEREON IS PROH181TED UNDER COPYRIGHT LAW ANCHOR4CE.AK 99507 2326 FB 221-38 229-30 223-8515 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-790,4 Fax: (907) 343-7997 http://wvm.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP221204 Work Type: Septic Upgrade Tax Code Number: 01707371000 Site Legal Address: GRECIAN HILLS BLK 2 LT 6 G:2940 Site Mailing Address: 8020 COX DR, Anchorage Owner: TUTTLE BETTY ANNE . Design Engineer: GARNESS ENGINEERING GROUP LTD This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms 6/29/2022 6/29/2023 15260 Z Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing �C) .4' ( Nec"��n9 t'nee r, G �' , Ctnj C►'laY9 _tb /)Orf -b �—'►'eld. Received .� Issued By: y G 6V10e J -to /4G va✓I l e x Date: u 2_ Date:11 ZG1 ZZ a ON-SITE SEPTICMELL PERMIT APPLICATION Parcel I.D. 017-073-71 Property owner(s) BETTY WHITE C/O DION WHITE Mailing address Site address 8020 COX DRIVE *ANCHORAGE, AK Day phone 907-441-7542 Legal description (Sub'd., Block & Lot) GRECIAN HILLS; BLOCK 2, LOT 6 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (Z all that apply) Absorption Field nx Initial ❑ Single Family (SF) (w/wo ADU) Septic Tank nx Upgrade Fx] Duplex (D) ❑ Holding Tank E] Renewal❑ Multiple Dwellings El Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: A 5 � 5 Waiver Fees: Date of Payment: _ f 111) � Date of Payment: Receipt Number: — 0 5 $1 L16 Receipt Number: Permit No. 0 S P�A 1109 Waiver No. GADevelopment Services\Building SafetyNOn Site Water and WastewatefformsUient Forms\Permit Application.doc C&M ENGINEERING SERVICES Ph: 907-854-5558 Municipality of Anchorage Onsite Water & Wastewater Program 4700 Elmore Rd Anchorage, Ak 99507 RE: Proposed Septic System for Grecian Hills Block 2 Lot 6 Dear Reviewer, Prior to our planned inspection, we were notified of several issues with the septic installation at the above referenced property. The excavation was not opened and closed in the same day. While this is not in violation of the permit requirements, we have re -iterated to the installer that the excavation needs to be opened and closed in the same day or covered and heated during freezing conditions after OCTOBER 151h Concerns were raised regarding the placement of filter sand per plan. The filter sand was installed in the upper trench as shown in the attached profile views. We also note that a function of the sand appears to have been to provide additional treatment for the originally designed CAT II treatment system to treat the effluent quality similar to a CAT III system. It was not our intent for the drain field design to be changed, however the CAT III system already produces higher quality effluent, so the additional filtration is not needed. During inspection, we verified the excavation depth was up to 4' at the deepest point and as shallow as 2.5'. The max excavation depth was supposed to be 3', but the placement of additional sand at the deep (over -excavated) end of the trench mitigates concerns with over -excavation. During inspection of the installed distribution pipe, we observed that the invert of the pipe to be as shown on the profile drawings. This results in approximately 6' of the length of trench on the East end being ineffective because it was installed too deep into the topsoil layer. We are proposing to discount that absorption area and the area on the east end wall of the trench: (2x6' x 1' + 5'X1' = 22 sqft) Subtracting 22 sqft from the apparent 220 sqft of trench as designed, leaves well above the 100 sqft required. Note that the entire upper trench could be discounted as the lower trench would have 110 sqft of absorption area, still meeting the minimum requirements for the system. We perc'd a ML layer at the upper trench to confirm permeability. The percolation rate was 69 minutes per inch. This area will effectively convey effluent horizontally and vertically; however that is not currently considered in the design. The application rate for these soils would be 1.0. By inspection, the upper trench (as constructed) effectively has more absorption area than accounted for in the design. The attached soils log shows the location of TH — CM, TH-CM2 and the perc pit. Soils were only logged at TH-CM. TH-CM2 and the perc pit revealed matching soil conditions. Groundwater was not encountered in any of the holes. The soils in the perc pit were very wet. A traditional pre-soak was not performed because the soils were effectively pre-soaked naturally. We note that the ML layer was gray and is visually similar to CL. Close observation revealed the presence of mostly fine silts and sands with some apparent clay particles. The excavation of TH-CM shows that the west end of the upper field is more than 3 -feet above any impermeable layer as required. Groundwater monitoring in GEG Th -1 and the dry hole at Th -CM and Th -CM2 confirm that the upper trench meets groundwater separation distance requirements. The GEG perc pit apparently had water and pea gravel in it. These conditions were not replicated at the two closer testholes we excavated. The department raised concern that the upper field may encroach on the groundwater table. The required separation distance is 2 -feet. Based on the 2' water depth in the GEG perc pit near the west end of the trench, there is 2 -feet separation between bottom of sewer rock and the highest observed groundwater table. Our inspection of bottom of trench on 10/12/22 revealed DRY soils consistent with the soil log for TH-1. The ML layer observed was visually better than expected and contained some coarse sand in addition to the silt/clay sized particles. Groundwater was at a depth of approximately 5.5 -feet. The groundwater tube was removed in accordance with code requirements. After discussions with the department, it was determined that the upper trench was required to have segment lengths of 20 -feet or less. The distribution pipe on the upper trench was redone per plan. Additional notes: • The side slopes are to be 3:1 max for both trenches. • The Contractor verified that they filled the existing trench with sand as required. • The calculations attached to the MOA approval documents for the tank configuration indicate a factor of safety of 2.2 against flotation on an empty tank with water at the ground surface without the addition of supplemental ballast. These tanks have flanges to help prevent flotation. We are requesting a change order for the upper trench as -installed. We are not requesting a change order for the lower trench at this time. Thank you for your time in reviewing this change order request. Please do not hesitate to contact me at 907-854-5558 or by email cgbalzarini(o-),gmail.com with any questions or concerns. Sincerely, Charles Balzarini, PE 10/13/22 Revised 10/17/22, 10/18/22 10/25/22 Ik oe CHARLES G BALZARINI` CE 13854 4w�i AWA- ���� FESStON'�?�.�'�' 09 GREC1AN HILL PRORLE BLOCK 2 I.OT n WEST END OTTOM OF PIPE DP OF SAND 'IG. GRADE F WITHIN >F- GEG PIT AT GEG 'ENCH �c� °F A�gslll 49 RL �CHARLES G BALZARINI + �F`••. CE -13854 •'`�� iliF�PROFE5S10NP�-� ORIG. GRADE BOTTOM OF TOP OF SAN BOTTOM OF 9 OF Al. 5 —6 1/2 LENGTH ���P�. WHERE ABSORPTION ," oe S REDUCED CHARLES G BALZARII� . r GRECIAN PRORLE HLLS BLOCK 2 LOT 6 EAST END Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section a� 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 WwW.muni.org/onsite (907) 343-7904 I R'y�S • a 9 �r49• e ®•eee eseeeo• ••• o•eee ® •.•®•e..eess o•• 0 arles G. BAllI I ; ®®`��%�'• CE • 13834 -4 Soils Log - Percolation Test ®a`�'fi•'°•{Q(4 �i��'� Performed For: l t` �-�A� 1 C GC S i L 6 Da t P rf d 1l 114& e e orme . Legal Description: 2;4. Township, Range, Section: Slone 1 �- Gdvl 1- r--� 1 Z9 -t-,5 nz- 2- 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18- 19- 20 - COMMENTS —7 " WAS GROUND WATER Depth te� ENCOUNTERED? (Vv IF YES, AT WHAT DEPTH? S r Depth to Water After O Monitoring? N P E Date: —A/4-- Site Plan NDateG U2/7 Net Time 30 Depth te� Net Drop 7 PERCOLATION RATE tminutesfinch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND 2.� _- --s�— ---�L_ FT Ow PERFORMED BY: rZoQf��>yL PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DAITE.THDATE:IS ill%WAS �— ®®®E OF_ , Go-i;z f Municipality of Anchorage••,tJGINEERs r ••s��, Development Services Department 4 On -Site Water and Wastewater Section p� "'•••• •* 4700 Elmore St. • '•'•••• ... P.O. Box 196650 Anchorage, AK 99519-6650 S �9•••.'••••••••...... m :Charles l Ba1zer1 n! ; ., Q www.muni.org/onsite 00. . (907) 343-7904 ®J' •• CE. j s 4�iw .°� Air. ®�®�opgr.ft � Soils Log - Percolation Test e o °�ss►o ice. Performed For: wP17-C— Date Performed: Legal Description: PFcxAy /,q -t (5 s2 1,6 Township, Range, Section: `T �[ - C wl a. Depth 2- 3- A 4- 5- H 7- 8- 9- 10- 11- 12- 13- 14- 15- 16- 17- 18 19- 20 - WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT DEPTH? L Depth to Water After 0 P Monitoring? E Date: Site Plan NONE Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE (mmuleshnch) TEST RUN BETWEEN FT AND _ COMMENTS '50,T 4-5 �-Ze �77tM {714(- L -,q R— Com. �j o4�t/t'S c✓ t`_ �l Sd�t G Etf t}�D LA?CtER A.10 6 TF PERFORMED BY: PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL G B N PERC HOLE DIAMETER FT ERTIFY THAT THIS TEST WAS EFFECT ON THIS DATE. DATE: et(g" 2 ION0NM%0�n MENUMMEMEM ON MWEEMEM EMEMEMEMEM NEEMMEM ENEEMEEMME ENEEMMEMMMI Reading Date Gross Time Net Time Depth to Water Net Drop PERCOLATION RATE (mmuleshnch) TEST RUN BETWEEN FT AND _ COMMENTS '50,T 4-5 �-Ze �77tM {714(- L -,q R— Com. �j o4�t/t'S c✓ t`_ �l Sd�t G Etf t}�D LA?CtER A.10 6 TF PERFORMED BY: PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL G B N PERC HOLE DIAMETER FT ERTIFY THAT THIS TEST WAS EFFECT ON THIS DATE. DATE: et(g" 2 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221204, Deb Wockenfuss, 06/29/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221204, Deb Wockenfuss, 06/29/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221204, Deb Wockenfuss, 06/29/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221204, Deb Wockenfuss, 06/29/22 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP221204, Deb Wockenfuss, 06/29/22 COX DRI VE A/ R9 55' SQ" W R7 2/1 N8955'54"W87.20 SURVEY ORDERED BY: diose WNLe THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SNOW ANY CONFLICTS BETWEEN EXISTING STRUCTURES AND PLATTED LOT LINES ANDlOR EASEMENTS; AND IS NOT TO BE USED FOR POSITIONING ADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES. EASEMENTS OF RECORD, OR ANY LEGAL ENTITY, OTHER THAN THOSE APPEARING ON THE RECORD PLAT ARE NOT SHOWN HEREON( UNLESS INDICATED) NOTE: FENCELINES THAT MAY APPEAR ON THIS DRAWING ARE NOT TO BE USED TO DETERMNE PROPERTY LINES OR POSITION ADDITIONALIMPROVEMENTS. ANY PAVING SHOWN HEREON MAY BE APPROXIMATE DUE TO EXCESSIVE SNOW AND/OR ICE. THE SURVEYDATA ON THIS DRAW/NGISPREPARED FOR THEOWNER OFRECORD ONLY. ANYCOPKA4G; OR UTILI27NG THE DATA HEREON IS PROHLB/TED UNDER COPYRIGHT LAW -OF Arq�;4p x:"49 TH*y6 SHANE A. HOLT �0 a �p LS -6914 AS�BU/LT SURVEY I" =301 NO CORNERS SET THIS DATE I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT6 BLOCK2 GREC/ANHILLS ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST OTHER THAN NOTED. DATED AT ANCHORAGE,ALASKA THIS 8 TH DAY OF APRIL . 2022 2326 F8221-38 HOL T LAND SURVEI7NG 9309 GROVER DRIVE ANCHORAGZAK 99507 223-8615 i.,.IEi!...L.L. OG;E; I:::II:~:E: [;i:Ei:[;]Uilli:;i:t!E[)F:Ib~E:, I'"JLJE;T E:Eil i~:E'1"UI:;::F,IEE:, TO Ed::: q"F.iE!i i.,.!E::L.L. E!:F:'i!i::C: ]i F:' ;[ CI::FT' :[ [3N:!i!; F:li'dE:, E:ii3I'.,!!!~'I"Fi:UE;T:tlOI",~ ]I hi~i~; "F F:ij. L.. i::t 'F ]I Ci F~:'T,hiEFd'T i.,.I~[TH;[hl ~i:::O Ill] ~[ ~",l:i!i;I...ll:~:E % ]: C:i i'.,! E [::, 3" 0 i"1 Septe..~ber 23, 1977 Tom Turtle Star Route A Box 406A Anchorage, Alaska 9950~ Subject~ Permit Expiration Dear Mr. Tuttle~ A permit issued by this department for well and/or on-site sewer installation on Lot 6 Block 2 Grecian Hills Subdivision has expired since ~2~e issue dat~ exceeds one (1) year. In the event you still plan to install the well and/or on-site sewer syst~a, a new permit is required. The original soil test may be used to obtain a current per~.~it. If the well has been drilled, a well log should be Lent to this department to document the installation date. If you have any questions regarding the above matter, please dO not hesitate to contact this office immediately at 264-4720. Sincerely, Robert C. Pratt, Sanitarian MUNICIPALITY OF ANCHORAGE ADVANCED WASTEWATER TREATMENT SYSTEM MAINTENANCE AND REPAIR AGREEMENT THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and entered into as of this ZgTK Day of_gt �-RY _ of 20�, by and between JANEP NZAK , herein the "OWNER," and the Municipality of Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code (AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this Agreement agree as follows: 1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS), described as —A pv.4pTIX located at (legal description) A Et�,c.,S BLk 2 LoT 6 2. Maintenance, Revairs and Alterations. (Owner is required to read, understand and initial each section) �� Throughout the term of this Agreement, the Owner shall enter into a service agreement with an AWWTS service and maintenance provider approved by the Municipality or the manufacturer's representative. The AWWTS shall be maintained in a satisfactory condition capable of performing as designed and producing treated septic effluent in accordance with the equipment's approval for operation in the Municipality. It shall be the responsibility of the Owner during the term of this Agreement to pay for all repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This includes an annual maintenance fee (typically $400 to $600). Owner agrees that only maintenance and repair personnel approved by the Municipality or the manufacturer's representative will inspect and make any necessary maintenance, repairs or permitted alterations to the system. Owner acknowledges that regular maintenance of an AWWTS reduces the potential failure of the system, which could include sewage backup and costly repairs or drainfield replacement. (rev. 05/18/2018) Page 1 of 3 .� Owner acknowledges that the Municipality may request records of maintenance and repairs from the manufacturer's representative or maintenance provider. Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be assessed in accordance with AMC 14.60.030. I—P Owner agrees to grant the Municipality reasonable access to test and inspect the AWWTS. The Municipality will give at least 24-hour notice. Owner agrees that any sale or transfer of title of the property will not occur without a new Certificate of On -Site Systems Approval. Owner agrees that the AWWTS installation and maintenance requirements as provided by the AWWTS vendor/installer and approved by the Municipality are the governing guidelines for the construction, maintenance and repair of the Owner's AWWTS. J Owner agrees to maintain remote monitoring of the AWWTS as required by the AWWTS approval. 3. Term. The term of this Agreement shall begin on the date of approval by the Municipality to operate the installed system, or upon transfer of title, and shall continue while the AWWTS is operational or until title is transferred. 4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this Agreement shall in no way constitute a waiver of the provisions, nor in any way affect the validity of the Agreement or any part hereof, or the right of the Municipality thereafter to enforce every provision hereof. 5. Amendment. This Agreement shall only be amended by authorized representatives of the Owner and Municipality. Any attempt to amend this agreement by either an unauthorized representative or unauthorized means shall be void. 6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be brought in the Superior Court for the Third Judicial District of the State of Alaska at Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the parties under this Agreement. 7. Severability. Any provisions of this Agreement decreed invalid by a court of competent jurisdiction shall not invalidate the remaining provisions of the Agreement. (rev. 05/18/2018) Page 2 of 3 OWNER: By: (signature) Date: 247 FICS'-4OZY 4RX AffM S ({print name) STATE OF ALASKA ) ss. THIRD JUDICIAL DISTRICT ) The foregoing instrument was acknowledged before 20at , by c crept jr� 1� NOTARY PUBLIC FOR ALASI A My Commission expires: S- � -a-o7-14 MUNICIPA16ITY: By: (signature) 0.. 1.-,r5 (print name) me thiso?9day of Trbrwa.rj STATE OF ALASKA NOTARY PUBLIC jenie R. Sta. Maria 0 A,.yCOMMJSS1 metres 2-Z02V Date: _1// S 2,0 2 Title: C 1C , (rev. 05/18/2018) Page 3 of 3 Certificate of On -Site Systems Approval Parcel I.D. 017-073-71 Legal description GRECIAN HILLS BLK 2 LT 6 Site address 8020 COX DR Anchorage AK 99516 Current property owner(s) White/ Tuttle Expiration Date: Z "� X The On -site system(s) is/are approved for 4 bedrooms Conditional approval for bedrooms, with the following stipulations: Comments or advisories: Original Certificate Date: 3/15/2024 This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject system(s) is/are in substantial compliance with municipal code. The Municipality of Anchorage, Development Services Department (DSD) issues COSAs based upon representations provided by an independent professional engineer. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS: COSA Checklist X Well Flow Advisory Absorption Field Advisory Nitrate Advisory X Tank Age Advisory Arsenic Advisory Other COSA Approval_June 2022 N/IJ U H M P AC! ll IJ O /` N C O l G,AG E Development Services Department On -Site Water R. Wastewater Section Phone: 907-343-7904 Fax: 907-343-7997 Certificate of On -Site Systems Approval Application Z 1. GENERAL INFORMATION CC Parcel I.D. 01707371000 Complete legal description GRECIAN HILLS BLOCK 2 LOT 6 Location (site address) 8020 COX DR Current property owner(s) WHITE 2. ON -SITE SYSTEMS SIZED FOR 4 BEDROOMS Day phone 3. TYPE OF WATER SUPPLY: ❑® Private Well ❑ Private Well serving 2 dwelling units ❑ Private Well serving 3+ dwelling units ❑ Community Well or Public ❑ Water Storage 4. TYPE OF WASTEWATER DISPOSAL: ❑® Private Septic ❑ Private Septic serving 2 dwelling units ❑ Holding Tank ❑ Community Septic or Public Sewer 5. SEPTIC TANK: ❑ Steel ❑® Plastic ❑ Concrete ❑ Fiberglass Age 1 - See advisory if steel older than 20 years 6. ABSORPTION FIELD: ❑® AWWTS ❑ Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit Waiver request for: Expedited review requested: ❑® Distance: By applying for this entitlement, this property is subject to inspection by municipal On -site staff to verify the accuracy of the information provided. COSA Fee $ Z 0 Waiver Fee $ Date of Payment �r Z Z� —, 2-3 Date of Payment COSA # (� S C Z 3 1 31 / Waiver # COSA Application —June 2022 COSA Checklist_June 2022 COSA Checklist Legal Description: Parcel ID: If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____ A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test? Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date Comments __________________________________________________________________________________ B. TANK DATA Measured operating fluid level in septic tank Date of pumping Required maintenance completed, if AWWTS Comments: C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field. Per record drawings, field is insulated. Monitor tubes go to bottom of effective. If not, state depth into effective Presoaked required if (Required if house vacant or field not used for more than 30 days prior to date of test) Gallons introduced gallons date Any rejuvenation treatment (past 12 months) If yes, enter date Adequacy test date Results Pass Fluid depth prior to test in Water added gal New fluid depth in Elapsed time min Final fluid depth in Absorption rate gpd FIELD STATUS – POST RECOVERY Effective depth (per record drawings) in Effective depth used in Effective depth remaining in Comments/Deficiencies: COSA Checklist_June 2022 E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well on lot) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’ Yes if No ft Absorption Field on Lot > 100’ Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’ Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’ Yes if No ft Holding Tank > 100’ Yes if No ft Animal Containment > 50’ Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft N/A – Served by Community Well (not on lot) or Public Water From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required) Building Foundations > 10’ Yes if No ft Tank to Property Line > 5’ Yes if No ft Field to Property Line > 10’ Yes if No ft Water Main > 10’ Yes if No ft Water Service Line > 10’ Yes if No ft Surface Water > 100’ Yes if No ft Wells on Adjacent Lots: Private Wells > 100’ Yes if No ft Community Wells > 200’ Yes if No ft If tank or field is under driveway comment below F.ENGINEER’S COMMENTS G.CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation, unless noted otherwise. Name of Firm Phone Engineer’s Printed Name Date C&M ENGINEERING CHARLES BALZARINI, PE 3/10/24 T"itrate Advisory Certificate of On -Site Systems Approval # OSC231311 Subdivision: GRECIAN HILLS, Block: 2, Lot: 6 A water sample revealed a nitrate concentration of 5.41 milligrams per liter (mg/Q. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Since nitrates are known to slowly increase, we recommend you monitor the water quality. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On -Site Systems Approval. From Northern Testing Laboratories, Inc. Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water. Nitrate is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells. SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners, food solids, and bacterial cells. It may also result from the breakdown of organic matter buried in the soil. TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization. TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home water treatment systems such as softening or iron filtration does not readily remove nitrate. The best method for limiting nitrate in well water is source control. This can include avoiding overdosing of fertilizer near the well and maintaining good separation distances between septic tank leach fields and the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate. TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect the activity of nitrate in water. This laboratory uses several different wet chemical methods approved under the public water supply laboratory certification program. They also have test kits available, which the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can monitor the change in nitrate levels from their well. They recommend comparing the test kit results against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.