Loading...
HomeMy WebLinkAboutGRECIAN HILLS BLK 2 LT 8Municipality of Anchorage Community Development Department Page 1 of 3 On -Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907) 343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP151020 PID Number: 017-073-73 ❑✓ New ❑ Upgrade Name: Spinell Homes, INC. ABSORPTION FIELD ❑ Deep Trench ❑✓ Shallow Trench ❑ Bed [:]Mound Address 1900 W. Northern Lights Blvd. ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 4GPD/SF +2.7 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade +3.2 Ft Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Grecian Hills 2 8 Fill added above original grade 5.75 Ft. Gravel length 40 Ft. Township Range Section Gravel width 5Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 200 Ft2 1 N/A Ft. Well 74.4" 91.3* 88.9* N/A 64.1 TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑p Other Manufacturer Advantex Capacity 1,5000a1, Surface Water 100+ 100+ 100+ N/A Material Number of compartments Lot Line 12.8 10.0 13.1 N/A Plastic 2 NA Foundation 6.0 22.3 15.1 N/A LIFT STATION Manufacturer Capacity Curtain Drain 50+ 50+ 50+ N/A Anchorage Tank 250 Gal. Remarks *See Waiver Pump on level at 43 in. Pump off level at - 42 in. High water alarm at 45 in. Pump make and model P2005 Electrical Inspections performed by MoA Building Safety Installer . PTFE MATERIAL House to tank 3034 Tank to 3034 drainfield Pomraning Construction Drainfield 3034 CO/MT 3034 Inspector Pannone Engineering Services, LLC. BENCH MARK (Assumed elevation) 1 00f Inspectionest 9/26/2015 nd dates: 2 9/27/2015 Location and description 3`d 9/28/2015 4th Top of Deck COMMUNITY E ELOPME DE ARTMENT APPR01/AL Engineer's Stamp `,hof A���} Conditional Approval- Date 5` co ... .. . % •Steven. •�'anno*Ae� C 8149 . ApproveDates--I d ' -,---- e � I l �� Dat " ' ��,` qq `w IJf1C000lI R1::PU1L 1-1-I4.000 Anchorage P.O. I~"i:~ 196650 ANCHORAGE, ALASKA 99519-6650 (907) 264o4111 TONY KNOWLES. MA YOR DEPARTMENT OF HEALTH & HUMAN SERVICES January 9, 1987 G.E. Strode Frontier Engineers SR 5329 AF Wasilla, Alaska 99687 Subject: Lot 8 BLock 2 Grecian Hills Subdivision On-site Sewer Permit ~860258 A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1986. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentatiofl of the installation and to close the permit. ~ If a private engineer inspected the installation of the on-site sewer system the original as-built inspection report (three part form) must be sent to this office for review and approval, and for documentation. If there are any further questions, please call this office at 264-4744. Since~rely.~ ~R.W. Robinson Program Manager On-site Services RWR/ljw enc: copy of permit i)E]:'AF'.tTMEi]'",) J OF:. It:::',",~,.~ 'r'L.~ AND ENV Fr''=:...,:..,.. L STFd::Zii!i/'J", (-iJ,,~L, HL~I,'tFiJ:~E:.,~. CONTACT I::dd[]NIE: L. EG(.~L... DIiLSCRII-::': ) ........ ,~'I[)LD I NG 'T'ANI'::: 08/::;-"~ !'(E SUBD I V I S I ON: GREE; I AN H I t..,I_S LE)]": 8 BL,.,E)CK: -'2 SEC'I" I !IN: :~::'.5 'FOWNSH I F": ].~{:lq RAN[~[E: :~;~J L..C}'f' ::'' ?' ":::" :I. VJ~:;::'.60 (S[2 ,, t:::'T. [IR ACRES ) i c::er'ti[y that: ! af~i {'aTdii:i.].:i. al' t*.~i'LJ] 'Lh6~:, peqLtii"emen'J:.s ~'or' (:~n-...~ite sew(~H"s and foJ"'Lh [:)y 'l:.he J"luriicipa].ity (;f Anchor'a(je (J"IOA) and the Sta'Le c::,¢ A!aska. ~:'.,, ]: ~,,~ill :[.ns'LaI]. the syst¢.~m :i.n accoPclance~) ~it.h all MOb c(::HJes and r'egu].at:Lc)ns~ .9. r]c:J :i.r'i /:(:)fi]p}.J. atFH::6~:' (*]J.~..J"i tJ]E~, dcas:i.(JIq cl":i.t[BP~at c)f th:i.s per'mlt. :$. ]: ~,¢i].]. a(::Jhepe to a!]. MOA and St.,a'Le o{' Alaska r-eclu:i, pemen'Ls {of the:, se?.. I::;ac:k Z i::' A L i F'f' S}'A"[ ]: (::)lq ]: !ii; ! NS'!"ALL. ED i N AN AI::;'.EA COVERE:O BY M[]G BUt !....):)I NG CODI!:~:S, ']'!-iE:N ( :i ) AN i:ii:L, ii~::C] F~ ;[ ELAL. f::'EFd"'l :.[. T AND ]: NSPECT I ON MUS"f' BE OD"f'A I NED ~ (:~,?) A-S-BU :i: I....TS Wi:i..i Ni:)! L',E ~:iF'I:::'F:OVIE,~} W):"I'HOUT F:'~N EL.EC:']'RIC;Pd... !NSF:'EC'I"ION REF:'ORT.,I AND (3) THE ~..LEC;i!':,:.!iL:;¢.:fi.... Ni]l';'.K MUST BIE D.':]NF.~: BY A L:[CENSED [ii]....ECTRi[:;IAN, FRONTIER ENGINEERS, INC. Civil Design, Survey, Private Development, Construction Management July 23, 1986 Ms. Susan Oswalt Department of Health & Environmental Protection Municipality of Anchorage Pouch 6-650 Anchorage, AK 99502 Re: Lot 8, BK 2 Grecian Hills Dear Ms. Oswalt, This letter is written to notify your department that Frontier Engineers Inc. has examined the above referenced lot and finds that this lot is not capable of supporting an on-site septic system due to the soil conditions and other property constraints. We would therefore request a permit for a 3000 gallon holding tank for this property. The soil strata consists primarily of moist impervious silt with some trace of sand. Two open hole investigations were performed and a perc test was attempted with the result as shown on the ~attached test log. The blue gray silty soil underlying the topsoil and fill material was consistent In texture and nature. Some moisture was evident at varying locations withln the silt in both holes. The density and moisture of the silty soil precludes any septic system in this soil lens. The fill material overlying the blue gray silty soil is inconsistent ranging from peat and stumps to cobbly silt and varying in thickness. The inconsistency of this fill material and the topography of the area around this lot precludes use of a mound system. The septic system that had been serving this lot and house has recently been found to be inadequate and In violation of DHEP requirements. In order to bring this residence back into compliance we are herewith making permit application for a 3000 gallon holdlng tank. Attached is a plot plan showing the residence, lot dimensions and wells on adjacent properties. We would request a permit to Install this holding tank as soon as possible in order to minimize any future problems with the existing system. 2440 East Tudor Road, Suite 1140, Anchorage, Alaska 99507 (907) 561-7421 Ms. Susan Oswalt July 23, 1986 Page 2 Please call me at 561-7421 If you have any questions regarding this permit. We would appreciate notification by phone when the permit is ready to be picked up so that this problem can be corrected quickly. S I ncerel y, William C. Hagmaier, P.E. WCH/MS Enclosure 24~j E. TUDOR SUITE 1140 ANCHORAGE, ALASKA 99507 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: I 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16- 17- 18- 19- AN, Township, Range, Section: ~' ~_~ ,~'~'C ,2 ~". SLOPE WAS GROUND WATER ENCOUNTERED? S L IF YES, AT WHAT O DEPTH? ~ p E Depth lo Waler After Moniloring? Date: SITE PLAN , ,~INEER$ INC.:/, '-1140 ALASKA 99507 COMMENTS Reading Date Gross Net Depth to Net Time Time Water Drop ~ .... ~ ~" ~., ~ ', PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER . TEST RUN BETWEEN ~ FT AND ~ FT PERFORMED BY: ~'~'~' I ~'//"-~ ~ ~'~'~t'~CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE· DATE; 72-008 (Rev. 4185) HEALTH DEPARTMENT 327 EAGLE ST. ANCHORAGE, ALASKA 99501 2~?~2511 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM MAILING . ~. LOCATION ~_? ~o.)( .~/~/~-~'~.~'~;--.~/~'$~/./ LEGAL DESCRIPTIO S£?T',C TANK://'O/_/:~//./.~c~ ~F.~,~-~ DISTANCE FROm WELl //2 LIQUID CAPACITY ~ ~ ~¢:~ NUMBER OF ~ MATERIAl. ~'~,*-'-'..~--,~'--.~-'--~Z._ COMPARTMENTS GALLONS, INSIDE LENGTH /INSIDE WIDTH ~ DEPTH SEEPAGE SYSTEM: SEEPAGE PIT: NUMBER OF PITS EDIA OR WIDTH ,LENGTH ,DEPTH , LIN~~. i$ISTANCE FROM WELl ~'"'~~BUILDII~ FOUNDATION TILE DRAIN FIELD: TOTAL LENGTH DISTANCE FROM WELL ~ , FOU~.IDATION . NEAREST LOT LINE , OF LINES ., NUMBER OF S$~r~''''''~ DISTANTETWEEN LINES/ __.~H.? IN. TOTAL EFFECTIVE A AREA S DEPTH: TOP OF TILE TO FINISH GRADE DEPTH OF FILTER MATERIAL I~NE--'C~'TH TILE IN. ABOVE TILE WELL: TYPE ~.,,~//_~/_..~.z:'~ DEPTH/,~c~,~' /.,~.. DISTANCE FROM w WATER , , BUILDING FOUNDATION.~'"~,() ,,~4,,,.-. SAMPLE. ~ NEAREST ' OTHE /~$ NEAREST / SEPTIC ~ SEEPAGE ~ ~ , SOURCES_/~ LOT LINE / , SEWER LINE ., TANK , SYSTEM. , CESSPOOl DISTANCES: DIAGRAM OF SYSTEM ~ ,x~ . j J<' APPROVED ~ ' HEALTH AUTHORITY · ..... : HEALTH DEPARTMENT 327 Eagle St. Anchorage, Alaska 99501 279-2511 uase I~O.¥~ -} ~' SEWAGE DISPOSAL SYSTEM - APPLICATION & PERMIT NAME OF APPLICAN-I(_~./b~.,~'~ ~--.,'/.~ 4~'--.-~'''~T'''~- MAILING ADDRESS /' ~.~ C~& ' PHON~ NO. APPLICATION T0 INSTALL: SEPTIC TANK SEEPAGE PiT DRAIN FIELD 0THE~ , ~./~-.... ~ , , ~.oO~T,O. ~..~SU~TS ~D.~ZZ. ~..,c,~ ~ BELO%~ BE FILLED OUT BY HEALTH DEPARTMEBT ,.~p~so,~.~. ,~,.~. s~z~ o~T~ sa,va. ~ ~'% ~ ~'/ SEEPAGE ARE~ ..... TYPE' . ~%A~ SIZE ~L ~ ¢~ ,TYPE DIAGRA~ OF SYSTE~ I certify that I am familiar with the requirements of Greater Anchorage Area Borough Ordinance No. 28-68 and that the above described 7stem !s~ i~ acc°rdance with said c°de' August 5, 1987 George E. Strode SR 5329 AF Wasilla, Ak. 99687 Dear Mr. Strode, On May 17, 1986 the septic system on Lot 8 Blk. 2 Grecian Hills was determined to be in noncompliance with A~C 15.65.020. Following notification of this you obtained a permit for the installation of a 3,000 gallon holding tank. The permit was issued on August 5, 1986; on January 9, 1987 a letter was sent to you stating that the permit had expired as of December 31, 1986. To date this office has received no confirmation of the holding tank having been installed or that the other requirements of the permit have been met. As you are aware the requirements of the permit must be met and an as-built stamped and signed by a registered civil engineer must be submitted to our office. since this office has not received such confirmation and a visit to the subject lot on July 28, 1987 indicated that some work had occurred the following shall apply: 1) You have ten (10) days from the date of this letter to comply with the requirements of the permit. A new permit is required for any work performed in 1987. 2) The as-built submitted be completed by a civil engineer registered in the State of Alaska. 3) Failure to comply with the above will result in the issuance of a citation to AMC 15.05.080; 15.65.020; 15.65.040; and 15.65.090. Please contact this office at your earliest opportunity. Our telephone number is 343-4744 and our office hours are 8:00 a.m. to 5:00 p.m., Monday through Friday. Sincerely, Daniel N. Bolles DHHS / On-site Services FRONTIER ENGINEERS, INC. Civil Design, Survey, Private Development, Conetructlon Management March 27, 1987 Ms. Susan Oswalt Department of Health & Human Services Municipality of Anchorage P.O. Box 196650 Anchorage, Alaska 99519-6650 Re: Lot 8, Block 2, GrecianlHills Subdivision Dear Ms. Oswalt: MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION 1987 RECEIVED Please be advised that this firm should no longer be contacted regarding the health violations on Lot 8, Block 2, Grecian Hills Subdivision. This firm designed an acceptable system for waste- water control on this lot approximately August 1, 1986. The design was approved and a permit for construction was issued. ~S~bseqUent to that time, a system was installed by the owner. However, this firm cannot verify construction compliance with the approved design. If the owners' ability at construction is as poor as their ability to pay for engineering services, I can only surmise that the installed system is questionable. We bring this system to your attention inasmuchas the Grecian Hills Subdivision is a problem area within Anchorage, and this lot in particular had been a violation for some time prior to our work for the owners. We have notified the owners numerous times in reference to the completion of the system, but we have received no contact from them regarding their obligations. We do not wish to burden you with a problem lot, but inasmuchas we have no enforcement ability ourselves, we must at this time remove our firm from this system design and request that the Department of Health & Human Services finalize this system. The owners' names and phone number are listed on the permit. Should you need any additional information, please contact us at the address below. Sincerely, William C. Hagmaier, P.E. 2440 East Tudor Road, Suite 1140, Anchorage, Alaska 99507 (907) 561-7421 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. In conducting an adequacy test, I attempt to provide a thorough, conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations. The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition, ground water levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone 6. DSD SIGNATURE System #1 Approved for _ bedrooms System #2 Approved for bedrooms Dis pprove 2 L---- Conditional approval for J bedrooms, with the follow a Date 10/28/15 �e OF Akq lklk *: a9 •.* • Steven • NM8ne ,•. CE—$149 •L AW �l� �4FE5510�._ A_d ITE r WATT=}��,, "T WAS7EWATE o GRAM �; . � W f nrirninal Certificate Date;. Tnunacipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only urepresentations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet � , ..