Municipality of Anchorage Page 1 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 • Anchorage, Alaska 99519-6650 • Telephone: 343-4744
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW9901 60 PID Number: 051-131-08
NamCh
Charles B. Fetters
Wastewater System: ❑ New M Upgrade
Y P9
Address:
23526 Greatland Drive, . Chugiak, Ax
'ABSORPTION FIELD
Phone:
rooms;
No, of re(eede 3)
Th
X�(Deep Trench ❑Shallow Trench G Bed G Mound ❑ Oiher
LEGAL DESCRIPTION
Soil Rating: .6
Total Depth from original grade:
GPD/So. Ft.
12.5'
Lot: Block: Sub ivision:
4 2 Greatlanc�l Est. #1
Depth to pipe bottom from original grade:
Gravel depth beneath pipe
6' Ft.
6.5' Ft.
Township:
Range:
Section: -
Fill added above original grade:
Gravel length:
.5' Ft
73 Ft.
WELL: ❑New ❑Upgrade
Gravel depth:
Number of lines:
Distance between lines:
3 FL
1
— FL
Classification (Private. A.B.C):
Total Depth:
Cased To:
Total absorption area:
Pipe material:
Existing
Ft.
I Ft.
949 . SG.Ft.
ASTM D3034 'PVC
Driller
Date Drilled.
Static Water Level:
Installer. -
Date installed:
Ft.
MM&M Contracting
8/13,17/99
Yield:
Pump Set at:
Casing Height Above Ground:
TANK
- -
GPM
Ft.
Fl
.
SEPARATION
DISTANCES
XI septic G Holding G S.T.E.P-
To
Septic
Absormlon
Lift
Holding
PubliHPrivate
Manufacturer.
Capacity in gallons:
From
Tank
Field
station
Tank
S—Linx
Anchorage Tank
1
Well
>100'
>100'
N/A
N/A
N/A
Material:.
Steel
Number of Compartments:
Two
SurfacWater
>-100'
>100'
N/A
N/A
N/A-
LIFT STATION - N/A
Lot
>51 -
>10'
N/A
N/A
N/A
Size in gallons:
Manufacturer:
Line
Foundation
> 51
>10'
N /A
N/A
N/A
Pump on" level at:
'Pump off' level at:
High water alarm at:
Curtain
None
Noted
on Loi
Pump Make & ModelElectrical
I
Inspections performed by:
Drain
Remarks: Existing Service Line From
BENCH MARK
House Intercepted Near New Septic
Location and Description:Bottom Step Front
Tank Location.
Entrance to House
Zabel Diverter Valve Placed At Locati
nAssumed
Elevation:
100.0
shown. Existing Absorption Trench Remains in Tact.
ERti$A
° t/f;
esthole Deepened During Construction to Verifyb�°°°�l
Absence of Impervious Layer 6' Below Bottom of Trench.
Inspections performed ormed by: A. xarala Dates: 1st 8/l"i/99
2nd 8/17/99
9t11�y
Department of Health and Human Services approval
Reviewed and approved by: Date: ' / o -q
72-013 (1 Y1) MUA Lb
NOTE:
M
U
To
Municipality of Anchorage Page 2 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 - Anchorage, AK 99519-6650 - 343-4744
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number SW990160 PID No. 051-131-08
N
c
4F a
61 l 6 i
Existing Line From House Intercepted Just Prior
To Location of New Septic Tank.
aMI1111111
M
H
U
76.0
4.7' 68.3'9,'°se° sd.
_— la .
PROFILE AS -BUILT=°
HORIZONTAL SCALE 1" = 10' 4i=
NO VERTICAL SCALE r `(
�it" -001 r
Municipality of Anchorage Page 3 of 3
DEPARTMENT OF HEALTH AND HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. Box 196650 - Anchorage, AK 99519-6650 - 343-4744
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number SW990160 PID No. 051-131-08
MW
DVS2 1
M1.
C3 C1
GREAT LAND CIRCLE
Three
0% - 1%
cJ �
Existing
Well A B
DV Zabel D verter Valve S1 50.5 59.4
C Cleanou S2 53.3 64.6
M Monitor be DV 59.2 72.0
C3 52.6 69.6
M1 56.8 73.0
10''Utility Easement
.
PLAN AS-BUILT6a
.
SCALE 1" = 50' 6G�,�iia,�i;
MUNICIPALITY OF ANCHORAGE I
Department of Health and Human Services S -13 • ON 5-pwi
On -Site Services Program .17 , �� 3 i 30 ��
825 L Street, Room 502
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-4744
ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Permit Number: SW990160
Date Issued: Jun 25, 1999
Expiration Date: Jun 24, 2000
Parcel ID: 051-131-08
Legal Description: GREAT LAND ESTATES #1 BLK 2 LT 4
Design Engineer: 0014 Anderson Engineering Site Address: 023526 GREATLAND DR
Owner Name: Charles B Felters Lot Size: 90169 SQ. FT.
Owner Address: 23526 Grealand Drive Total Bedrooms: 4 Permit Bedrooms: 4
CHUGIAK , AK 99567-0000
This permit is for the construction of:
❑✓ Disposal Field ✓❑ Septic Tank ❑ Holding Tank ❑ Privy
All construction must be in accordance with:
1. The attached approved design.
❑ Private Well ❑ Water Storage
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
MAXIMUM DEPTH OF THE ABSORPTION TRENCH SHALL NOT EXCEED 10.5 FEET FROM GROUND
SURFACE.
Received By:
Issued By:
Date:
)%: `T2 �' 'tel Date: y — 25—/
June 17. 1999
Municipality of Anchorage
Department of Heath & Human Services
825 "L" Street
Anchorage, AK 99502-0650
Subject: Lot 4, Block 2, Great Land Estates Subdivision
Septic System Design
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The existing absorption trench on Lot 4, Block 2, Great Land Estates
Subdivision has failed and must be replaced. We are therefore requesting
a permit be issued to upgrade the system. A flow diverter will be placed
in line from the septic tank to allow use of the existing absorption trench
at a later date if necessary. The attached site plan and backup
documentation describe the proposed system and the location of the new
system.
The testhole placed on the lot revealed silty gravel with some sand. The
percolation rate was measured at 30 minutes per inch. No groundwater
was encountered during excavation and none was noted during the
monitoring period. We have therefore designed a deep absorption trench
with 8' of gravel beneath the distribution pipe. The trench will be 65'
long, 3' wide and have a total depth of 11.5' from the original ground
surface. The existing septic tank will be pumped, crushed, backfilled and
abandoned in place.
The ground surface of the lot is basically flat with only a minor slope
towards the north and the east. The absorption trench will be
constructed in a flat area of the lot and will not be impacted by the slope.
The lot is 300' long by 300' wide as are the adjoining lots. No conflicts
exist between the septic system on this lot and other wells or systems in
the area.
Lot 4, Block 2
.tune 17, 1999
Page Two
Great Land Estates Subdivision
If the system is constructed as designed the following statements apply:
1. The system, if constructed as designed, will have no adverse impact
on the wells in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact
on existing septic systems in the area or those to be constructed in
the future.
3. The system, if constructed as designed, will have no adverse
impact on reserved space, either surface or subsurface, on any lots
located in the area.
4. The system, if constructed as designed, will have no adverse impact
on drainage patterns in the area. The current drainage pattern will
be maintained.
Sincerely,
701ce'�'9F AA
�
Michael E. Anderson, P.E. V o
4,
Attachments +' '°yif a#.ft; ;.F,AVA,s f
Lot 11
GREATLAND CIRCLE (DRIVE
Lot 4
This Project
Lot 10
r
AREA MAR
' SCALE 1" = 100'
No wells are located within 100' of new septic system
GREAT LAND CIRCLE
65' Long X 3Wi e
X 8' Effective De th
Absorption Trench
i
Exis 'n
Tren h
TH1®
0
ckO
r
i
Zabel
Diverter
Valve
New 1 , 250 Ga' on
Septic Tank
0% - 1% III
l Four
Bedroom
Hou e
Existing
Well
10' Utility Easement
NOTE: Existing Septic Tank to be
Pumped, Crushed, Backfilled
and Abandoned in Place.
No Conflicts With Neighboring
Wells or Septic Systems.
SITE PLAN'
SCALE 1" = 50'
'49
PA ..oemi
aA=oyq �oaoo
NF.
LOT 4, BLOCK 2, GREATLAND EST. NO. 1
DESIGN FACTORS:
Four Bedroom System
Pere. Rate: 30 Min./Inch
Application Rate: .6 GPD/SF
SYSTEM REQUIREMENTS:
Deep Trench System
1,250 Gal. Septic Tank
8' Drainfield Rock
4 Bedrooms X 150 GPD / .6 GPD/SF = 1,000 SF of Absorption Area
1,000 SF/16 SF/ LF of Trench = 62.5 LF Trench Length
Therefore: Construct a Deep Absorption Trench System With One Lateral
65' in Length with 8' of Drainfield Rock Beneath the Lateral.
Distribution Pipe in Trench Placed at 3.5' Below the Original Ground
Surface. Total Depth to be 11.5' from Original Ground.
TYPICAL DEEP TRENCH SECTION
NO SCALE) Q
NOTE: Grade Area Over Trench to Drain Away. b o °'���
Minimum 4' From Groundwater. � 'Ti� fiy
Maintain 10' Separation From Lot Line. s"°.
Natural
31
BaC4Ifill
Geotextile
Fabric
6"
O
4" Perforated
PVC (Slots Down)
g�
Drainfield
_ Rock
i
3'
TYPICAL DEEP TRENCH SECTION
NO SCALE) Q
NOTE: Grade Area Over Trench to Drain Away. b o °'���
Minimum 4' From Groundwater. � 'Ti� fiy
Maintain 10' Separation From Lot Line. s"°.
qw 44
Municipality of Anchorage �v° a -,- j�
DEPARTMENT Or HEALTH &HUMAN SERVICES � °
825 "L" Street, Anchorage, Alaska 99502-D6SO 00
SOILS LOG — PERCOLATION TEST �, �......... 7 t
®I =. P.IG E. 0 '
PERFORMED FOR: MM&M Contracting DATE PER
LEGAL DESCRIPTION: Lot 4-, Bl ock 7 RrpAtl and F.statps I- "`
SLOPE SITE PLAN
1IFE10TI PT/OL
/.
2-
3-
4 -
GM 3 4GM
g ti t
10 Q"
i
11 �C •.k
,2-
13-
14-
15-
16-
2 13 14 1s 16 Bottom of
U �
17 Hole
18
19
WAS GROUND WATER
ENCOUNTERED?
1F YES, AT WHAT
DEPTH?
No
L
0
P
E
ND4
Mmunup? }hG b'30 �g�j
Reading DntI
Grua I Net
Time Time
I DepTh to Net
wmc Drop
1641
19:15 1 —
I it" I . —
*fz I
13!YS I
I 238"
s I
4f /57- I
1 .53 I "
11 I
I _T4s' 1
1 4 31$ I !'
I
I I
I I
1
I I
I I
I I
I I
I I
I
I I
I I
I
I
I I
20
��
PERCOLATION RATE
9
? �
at
Itrunutevmeh) PERC HOLE DIAMETER
• TEST RUN BETWEEN
•�
F AND FT
COMMENTS
Perc. Cavity presoaked prior
to
testing.
PERFORMED BY: ""•(t•C'tiC. G
MF& 1 `RTIFY THAT THIS TEST WAS PERFORMED IN
Michael E. Anderson 1,1
ACCORDANCE WI i H ALL STAT S AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DAT E DATE: ,/7
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 4, BLOCK 2, GREAT LAND ESTATES
GENERAL:
1. The scope of this project includes the procurement and
placement of a new 1,250 gallon septic tank. It also
includes the construction of a new 65' long x 3' wide x 8'
effective depth absorption trench at the location shown on
the attached Site Plan. The existing septic tank must be
pumped, crushed, backfilled and abandoned in place. A Zabel
flow diverter valve must be installed to allow use of the
existing absorption trench at a later date.
2. Construction shall be in accordance with the approved site
plan, design drawings, Municipal Permit with any special
provisions or conditions, and all applicable State and
Municipal Wastewater Disposal Regulations.
3. The Contractor shall be
responsible
for
obtaining all
underground utility locates
and for the
layout
of the septic
system and verification of
the location
of all
lot lines.
4. Unless specifically agreed otherwise, the contractor shall
be responsible for final grading areas subsequently
depressed from soil settling. Property owner shall be
responsible for revegetation of affected areas unless
specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must
be certified by the Municipal Department of Health and
Human Services for system installations. Owners installing
their own systems must receive prior approval from D.H.H.S.
before beginning system installation.
SEPTIC TANK INSTALLATION
1. The 1,250 gallon septic tank must be procured from an
approved source and installed at the location shown on the
plans.
Lot 4, Block 2, Great Land Estates
June 17, 1999
Page 2
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts
for pumping access.
3. The septic tank shall be sufficiently bedded to prevent
settling or shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of
12 inches above final grade.
5. Tanks installed without 4' of cover shall have a minimum of
2" of direct burial insulation.
6. A foundation cleanout shall be installed one to four feet
from the building foundation. Two cleanouts are required
between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive
slope exists away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown
on the design. The bottom of the trench shall be within 2"
of level.
2. Distribution piping
must
be placed
level with perforations
down atop a level
bed of
drainfield
rock. Rock should then
be placed over the
pipe
to provide a
minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between
the drainfield rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the
locations shown on the design. The portion below ground
must be perforated.
5. Contractor shall verify the septic tank and drainfield are a
minimum 100' away from any private water wells in the
area, 150' from a Class "C" Well or 200' from any community
well.
Lot 4, Block 2, Great Land Estates
June 17, 1999
Page 3
6. Direct bury insulation must be placed over the distribution
system if less than 3' of backfill depth is available. Finish
grade over the trench must be mounded to prevent
settlement or depressions.
7. Grade area surrounding the absorption trenches to drain
away.
8. A minimum 2' of accepting soil is required below the
drainfield rock for a 5' wide trench. Contractor shall verify
this condition prior to placement of the rock. All pockets of
unacceptable materials must be removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a Municipally approved
septic tank manufacturer.
2. The following pipe materials are approved for use in septic
system installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C.
(perforated and solid), ASTM F810 or H.D.P.E. (perforated,
but not solid) and ASTM D2662 or A.B.S. (perforated and
solid).
3. Insulation shall be at least 2" thick extruded direct burial
polystyrene (Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with
watertight couplings (Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must
be installed between the final drain rock layer and the
native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than
3% passing the #200 sieve.
Lot 4, Block 2, Great Land Estates
June 17, 1999
Page 4
INSPECTIONS:
A minimum of two inspections are required by Municipal
Ordinance. These inspections must be conducted under the
supervision of a professional engineer registered in the State
of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation
of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement
of the geotextile fabric, gravel, distribution piping,
standpipes, cleanouts and insulation. No backfill should be in
place at the time of inspection.
Contractor shall provide a copy of all field survey layout and
construction notes for use in preparing the certified as -built
of the completed system.
,MUNICIPALITY OF ANCHORAGE: Q
He. h and Environmental Prote on
Fourth Floor West
825 L Street
Anchorage, Alaska 99501
264-4720
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
NAME C�r%) QOlLZ�-e - MAILING ADDRESS e110 Q-"V0dZAo�'D46LI,U&PY Q42610 MONE G88- b" )
LOCATION 6%V' fTF P APA � CatL< bl- LEGAL DESCRIPTION "4 QNV" 2, <q'? -CAT `AND QTR -Its
SEPTIC TANK:
DISTANCE % NUMBER OF
FROM WELL rd -% MANUFACTURER QLpC-� MATERIAL S� L- COMPARTMENTS
INSIDE LENGTH 'v INSIDE WIDTH r� LIQUID DEPTH t4ja LIQUID CAPACITYM GALLONS.
TILE DRAIN FIELD:
k f TOTAL LENGTH 6
DISTANCE FROM WELL _FOUNDATION `ICS —NEAREST LOT LINE 3� OF LINE S8
# of Lines L ©N 1 S��1/DISTANCE BETWEEN LINE—TRENCH WIDTH !-0 IN. TOTAL EFFECTIVE
ABSORPTION AREA SQ. FT. LENGTH OF EACH LINE
W DEPTH OF FILTER
DEPTH: TOP OF TILE TO FINISH GRADE _G_—MATERIAL BENEATH TILES -IN. ABOVE TILE IN.
SEEPAGE PIT:
DIAMETER OR WIDTH LENGTH_, DEPTH
Log Crib _Rings_ Crib Size:' DIAMETER_DEPTH DISTANCE FROM: WELL
TOTAL EFFECTIVE
BUILDING FOUNDATION_, NEAREST LOT LANE ABSORPTION AREA (WALL AREA) SQ. FT.
Well 1ND
Class:V,t,4 Depth:
Well Distance To: Lot Line
Bldg: Sewer Line: 1p�z
Pipe Materials:
# of Bedrooms:
Installer: 'FR'Efl laAM%Li-8w %W%
Remarks:
�C\L.
ku e o- A ti *M V�r btl HOLE
\ ♦ �`` `, S
i
I
I
i 1
a I I
I
I ►��
14
r
t�T�l R R
\ ♦ �`` `, S
^-��
`
��� � � :1 �
���
/~`\z
�� ���� ����
/ Y1�`
����'�� /��/[
"
TMENT OF
HE�LTH
HND ENVIRONMENTHL PkUTECTION
—�--
r�� �25 /L'
'7'�/7/~L��
ST�EET/
����
HNCHORHGE/ HK 99501
���� ��� ����
s
2-4_�--�����
ID
Yl' \
/
IVAT K L. L. Fog 141131
11 A A 1-
1 " 11 ' E.'- :,S--'.-'4*-'-.*.: UP IETE IFY, ���9 ,1
1 , 0"' t-�5 �
PERMIT
NO ( 7801]1 )
�
F1PPLICHNT
I
C/OGEN DELIYERY CHUGI�K
6�8 2141 �
LOCHTION
GREHT LHND CIRCLE
DR
�
LEGHL
L4 B2 GREHT LHND EST
LOT S1":!E
SQUHRE FEET
TYPE OF
SOIL HBSORBTION SYSTEM
10 TRENCH
MHXIMUM
NUMBER OF BEDROOMS =
4
SOIL RHTING 125
`
THE REQUIRED SIZE OF THE SOIL HBSORPTION SYSTEM IS:
��1- U jr 14 L. �K Ph (of -T- 10-1 ANT A. �9 9_- ��
+
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRHINFIELD
THE DEPTH OF 8 TRENCH OR PIT IS THE DISTHNCE BETWEEN THE SURFHCE OF THE
GROUND HND THE BOTTOM OF THE EXCHVHTION (IN FEET)
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRHVEL DEPTH IS THE MINIMUM DEPTH OF GRHVEL BETWEEN THE OUTFHLL PIPE
HND THE BOTTOM OF THE EXCHVHTION (IN FEET).
�I Iff IE'.-- 50 M 1=1 -V 1 Cl "T- 101 X1 K'�I A'! � P�*.--�n L --- L- �D��
PERMIT HPPLICHNT HHS THE RESPONSIBILITY TO I1,1100RM THIS DEPHRTMENT DURING THE
INSTHLLHTION INSPECTIONS OF HNY WELLS HDJHCENT TO THIS PROPERTY HND THE
NUMBER OF RESIDENCES THHT THE WELL WILL SERVE
�:,:n 1 1"J'A F,:m� IF�-' C::::' V 31:: !1-:-,H P -A Fog FT" g."HE: P.* -::u ~�~
BHCKFILLING OF HNY SYSTEM WITHOUT FINAL INSPECTION AND HPPROVHL BY THIS
DEPHRTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN H WELL HHD HNY ON-SITE SEWHGE �ISPOSHL SYSTEM IS
100 FEET FOR H PRIVHTE WELL/ OR
150 TO 200 FEET FROM H PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL
WELL LOGS HRE REQUIRED HND MUST BE RETURNED TO THE DEPHRTMENT WITHIN ]0 DAYS
OF THE WELL COMPLETION
OTHER REQUIREMENTS MHY HPPLY. SPECIFICHTIONS HND CONSTRUCTION DIHGRHMS FIRE
HVHILHBLE TO INSURE PROPER INSTHLLHTION
1: -T- 1071 -Wo" I ����HE: VCR low �FT.". ���� fl -MD
I CERTIFY THHT
1: I HM FHMILIHR WITH THE REQUIREMENTS FOR SEWERS AND WELLS HS SET
FORTH BY THE MUNICIPHLIT9 OF HNCHORHGE
2� I WILL INS"FF LL THE SYSTEM IN HCCORDHNCE WITH THE CODES
]: I UNDERSTHND 1 -HAT' THE ONbSITE SEWER SYSTEM MAY REQUIRE ENLHRGEMENT IF THE
RESIDE E I E ODE TO INCLU ORE THHN 4 BEDROOMS
SIGNED���������l��'
HPPLICHNT PRED COLLEY //
ISSUED BY
__ VI0
reg �D"-A 1 C,����L �.� �F� �i �A ���������C
^ � DEPHRTMENlOp"IEHLTH HND ENV lHOWMENTHL ECA' 1UN
L. TREET, HNCHORHGE, HK. 99�- .
^ v 279�2511
' 0 �P.A. �L-'. k�� F-4 F-- 14�! M X 0
HPPLICHNT F COL EY 440 N KLEVIN 27472(9
L0CHTIUN GHEHT LAIN[) CIkCLE DRIYE
LEGAL�QT4 8L 2 GREHT LI -IND 2��THTES LOT SIFEET
lYPE OF SOIL HBSORBTION SYSTEM IS: TRENCH
MHXIMUM NUMBER OF 8EDROOMS = SOIL RATING, (SQ FT/BR)z 125
THE REQUIRED SlZE OF THE SOIL H8SORPTlUN SY�T1-41 IS:
~��
THE LENGTH DIMENSION .1.1n THE LENGTH (IN FEET) OF THE TREN0~ OR DRHINFIELD�
THE DEPTH OF H TRENCN QR PIT l5 THE DISTHNCE BETWEEN THE SURFACE OF THE
UTION N FEETQH
[HERE IS NO SET WIDTH FOR TRENCHE��
THE GKHVEL DEPTH lS THE MINlMUM DEPTH OF GRAVEL BETWEEN THE UUTFHLL PIPE
HND THE 8OTTQM OF (IN FEET).
- - - �ff� --a�
���� cA .0,1.0*..,A�-A
H PHCKHGE PLHNT MHY 8E INSTHLLED HT THE PERMITTEE/S OPTI8N SUBJECT TO THE
FOLLOWING CONDITIONS:
i� EITHE�� H CLHSS I OR II NSF HPPROVED PLHNT MHY BE INSTHLLE[l
2 H CONTINUOUS MHINTENHNCE AGREEMENT IS REQUIRED. IF H MHlNTENHNCE
AGREEMENT IS NOT KEPI CURRENT YOU MAY 8E REQUIRED TO ENLHRGE -1111--
YOU
HEYOU P11 -:1Y BE SUBJECT TO PRUSECUTIOW.
-U-�K� ��� ��������'����� ���� ���LJ���� —�—
BHCKFILLING OF. ANY SYSTEM WIfHOUT FlNHL INSPECTION HND HPPROVHL BY THlS
DEPHRTMENT WILL BE SUBJECT TO PR8SECUllON.
MINIMUM DISTHNCE BETWEEN H WELL HND MY ON-SIlE SEWHGE DISPOSHL SYSTEM IS
1@0 FEET FU� H PRIYHTE WELL OR 200 FEET FQR H PUBLIC WELL
WELL LOGS ARE' REQUlRED HN& MUST BE 1-,--'E7URNED TO THE DEPARTMENT WITHIN I0 DHYS
UF |HE WELL i�OMPLETIUN
OTHEH REQUlREMENTS MAY HPPLYSPECIFICHTIONS HND CONSTRUCT�QN DIHGRHMS HRE
HVH11.18LE TO INSURE PRUPER INSTHLLHTION.
I CERTIFY THHT
FHMILIHR WITH llfE REQUIREMENTS FOR ON-SITE SEWERS HND WELLS AS SET
FURTH 8Y THE MUNlCIPHLITY OF HNCHORHGE
2� I WILL INSTHLL THE IN HCCORDHNCE WITH THE {X}DES.
]� I UNDERSlHND THHT THE ON~SITE SEWER SYSTEM MHY REQUlRE ENLHRGEMENT IF THE
RESIDENCE N ] BEDROdMS
SIGNED�~�
F='a'-h and Envi'_"O^.=l-_-nt:a . '� otection -
SOILS LOG
77-20
Perfov-.e for Fred Colley Date Performed $/3/77
Legal DescriptiA '- Lot 4, Block 2, Great Land Estates Subdivision
0" Red -broom, sandy silt w/organics (ML) 275 ft.2/bdrm.
Brown, well graded sand w/gravel
125 ft. /bdrm.
Brown, silty, sandy gravel (GM) 225 ft.?/bdrm.
p ,•',: Brown, wellgraded sand w/gravel
..� 125 ft.2/bdrm.
u
4-3
d.
14- `o
Total Depth - 15 feet
10
No water table encountered
1�
20
AVERAGE ABSORPTION AREA FROM SOILS LOG = 136 ft. 2/bdrm.
Date Net Tina l D-Pth �— Net Drop
r�
t 1 7
DRILLING COMPANY, INC.
P.O. Box 8-9113 • 3350 Mountain View Drive Anchorage, Alaska 99508 • Telephone (907) 276-8800
Champion Drilling Company, Inc. is an Alaskan based corporation
co-a-litted to serving Alaskans. CHIUMPION offers complete on-s--i.te
rats services including water well. drilling, developing and pump
installation, and septic tank and drain field construction. Our
experienced staff will insure that your complete water system
s 4cistalled right the first time. Our water policy guarantees
v, -'-,i vour well will produce to Municipality of Anchorage specifications.
in addition to water well services, CHAi4PION also perforir:s soils
tests and percolation tests for septic systems within the municipality
o -f =ar:c:norage.
PRICE SCHEDULE
;• :.iter 5,ell Drillin
Cost per foot drilled_ -
Deaosit
iIf 500 feet or more of drilling
can be guaranteed - $17.50 per
foot drilled.)
oils Testing
$19.00 per foot
$1,500.00
CHAMPION furnishes backhoe - approximately $200.00 to $250.00
CLIENT furnishes backhoe $ 60.00 to $ 90.00
Ask About Our Guarantee
. . _ _ _ _ _ .. .. - .. .. . - -_ ..J IA/...... IA/..II..
R.AM AR D , IL1,91%G� WO _` S
SIX INCH WATER WELL DRILLED AND CASED OUT TO THE DEPTH OF
DRILLED AT THE RATE OF 927.00 PER FOOT.
PROPERTY OWNER rrt. T&e-d Cat tte 274-6511
sm my, ub, R"
997 Teet.
LOCATION OF WELL SITE • Btk. 'Lj Su,&. V-w�
DRILLER Bei e C ata a� R'arpv t &U.� byO;JA.
WELL LOG:
0----23' S.i UL &aua to th 10% ctac, dr-inden.
23---85' �Aavet and 4riea i,L . 0aidelr4. 30% cAal. Uinde ,*
85--113' �&auet and trautde-u.
113-162' Sdtt4 9AaueL tv th 15/ CtO4 triad -en.
162-187' Wet 4 i4 c i.a4. 30% gAaveL with a 4haar a.A iaaxe t at 162 deet. Two 9frQ.
lwxjLD4 Atind and q=vet '_du�SJX . 11 oy�h aw4OUoc,,'- n,,Ig
P tha ga-ilz t -I.t e -d c.Leaxi_ and .the _rycadaah Marl. d4 atalyd-e at 4.ix �.Piit am
that a &e -a. SeLlrtne uity'te, pA=,at 3/4 HO&4e, jhoutd dre t"ta Led f -am P -et 04
bot tam.
COST INCLUDES ALL LABOR AND MATERIAL FOR COMPLETION OF SAID DRILLING.
WRITE CHECK PAYABLE TO RAMPART DRILLING WORKS FOR THE SUM OF 94137.00
THANK YOU VERY MUCH.
BE,RNIE CLAUS OF RAMPART DRILLING WORKS
DATE uq• 23 -td, 1978-
�I'
.....-.. ,...... .-.....-...,- _. .- ... ,,. .,.-,-, ..-... . a..ar . or nccccccn nM PAFT r1f IF ACCr)l1NTS_
Parcel I.O.
'Fa-eLe0��(
Municipality of Anchorage
Development Services Department
Building Safety Division
Onsite Water and Wastewater Program
4700 Bragaw Street
i
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsfe
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
051-131-08
1. GENERAL INFORMATION
Complete legal description
COSA#
Expiration Date:
Lot 4, Block 2, Greatland Estates Subdivision No. 1
Location (site address) 23526 Greatland Drive Chuglak, AK 99567
Current Property owner(s) Charles B. and Nancy H. Fetters
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing Address
Day phone 688-0776
23526 Greatland Drive Chugiak, AK 99567
Day phone
Day phone
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: Throe (3)
3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well Individual On-site
Individual Water Storage ❑ Individual Holding Tank
Community Class Well ❑ Community On-site
Public Water System ❑ Public Sewer
The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an Independent professional civil
engineer registered in the State of Alaska. Certificates of On -She Systems Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues COSAs upon request to homeowners. Certificates of OnSfte Systems Approval
are varid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued
with new water sample results. (Certificates may be reissued for a period of up to one year with 7varid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of Onsite Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-sfte water
supply and/or wastewater disposal system is(are) In compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage, AK 99524
Engineer's Printed Name Michael E. Anderson, P.E.
5. DSD SIGNATURE
-kz Approved for _ bedrooms.
Disapproved.
Phone 522-7773
Date =22006
riff e�-+
i 49th /^1
Conditional approval for bedrooms, with the following stipulations:
L wmotsav
ruwaunencs:
COSA Checldist X Arsenic Advisory
Septic System Advisory Maintenance Agreements
Well Flow Advisory Supplemental Engineer's Report
Nitrate Advisory Other
BY ��/^L��-✓ f/V Original Certificate Date:
as „ft)
Municipality of Anchorage
• Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
47W Bragew Street
P.O. Box 196650
Anchorage, AK 995194;650
www.muni.org/onske
(907) 3437904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel ID: 051-131-08
Legal Description: Lot 4, Block 2, Greadand Estates No.'_'f
A. WELL DATA
Wen type PAvate If A, B, or C provide PWSID 0
Date completed 8/23/78 Sanitary seal (YIN) Y
Total depth -19-7ft Cased tD 197 ft.
FROM WELL LOG
Date of test 8rwa
Static water levet 157 ft
Well production 8 9—
p.m-WATER SAMPLE RESULTS:
Wall Log (Y/N) I Y
Wires property protected (YM) 1 Y
Casing height (above ground) In
AT INSPECTION
819/2006
156.7 (L
3.7 g.p.m.
CdHorm 0 colonkW100 mL Nitrate 3.26 mglL Other bacteria
II
Arsenic. NID mg/I Date of sample: 820/08 Cottected by: TXImtaough
B. SEPTIC/HOLDING TANK DATA
Tank TypelMaterial Ssptk/Stael Date instafled 513/89
Tank size 1.000 gal. Number of Compartrrmft 2 Cieanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (YIN) N High water alarm (Y/N) N
Date of pumping 4/17/2008
C. ABSORPTION FIELD DATA
Date installed 8/17199 Sail rating
Length 73 fL
Total depth 12-13 R
Pumper Sanitary Pumpers
(g.p.d./tl2 or fl2)bdrm) •8 GPD/SF System type Deep Trench
i
Width 3 R. Gravel below pipe 6-5: ft.
Elf. absorption area 949 fl2 Monitoring tube Y Depression over field N
Date of adequacy test WE
Results (PasalFail) Pass For 3 bedrooms
Fluid depth in absorption field before test 32 in. Water added 863 gal. New depth 37.5 in.
Elapsed Time: 88 min. Final fluid depth 32 in. Absorption rate >= 450 g.p.d.
Any rejuvenation treatment (past 112 mo.) (Y/N & type) If yes, give date
D. LIFT STATION
Data installed Size in gallons Manhole/Access (V/N)
'Pump are level at _ in. 'Pump air level at _ in. High water alarm level at in.
Datum Cycles tested Meet darn & circuit n qusemenb9
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tenkM station on lot :-IW On adjacent lots >1W
Absorption field on lot >1W
Public sewer main WA
Sewer /septic service One >25'
Animal containment areas None
On adjacent lots >1W
Public sewer manhole/deanout WA
Holding tank WA
Manure/animal excrete storage areas None
SEPARATION DISTANCES FROM SE17110HOLDING TANK ON LOT TO:
Building foundation >S Property We>S Absorption field >10'
Water main >10' Water service ane >10' Surface water >1W
Wells on adjacent krit >100'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property One >11r Building foundation >10' Water main >10'
Water Servs a One >10' Surface water >1 W Dnveway, perWngNa dde =rape >2S
Curtain drain None NOW Wells on adjacent lens >1W
F. COMMENTS:
O. ENGINEER'S CERTIFICATION
1 codify that I have determkred through rre/d krspecfions and 49th
review of Munk *W records that the above systems are in
conformance wth MOA COSH guddines in effed an this dateVs64MM p
Engkreer's Printed Name Michael E Anderson. P.E. c
Q
Date a/22nooe s44i
COSA Fee E
Date of Payment
7 Waterer Fee S
IN, Dated Payment
Receipt Number
Niq Racelpt Number
fRev. 11mm
SGS RCLM
1064571001
Client Name
Anderson Engineering
Project Name/q
MD632
Client Sample ID
Lot 4 Olk 2 Greatland Est.
Matrix
Drinking Water
Sample Remarks:
All Datcsrrimes are Alaska Standard Time
Printed Dale/rime 08/21/2006 16:56
Collected Date/time 08/092006 10:30
Received Daterrime 08/092006 13:50
Technical Director Stephen C. Ede
Allowable Prep Analysis
Pa ctcr Results POL Units WOW Container ID Limits Date Date Init
Metals by ICP/M$
Arsenic ND 5.00 ug/L EP200.8 A (<10) 08/15/06 08/17/06 Mll
SGS RcLM
1063566001
All Dates/Times arc Alaska Standard Time
Client Name
Anderson Engineering
Printed Date/time
08212006 9:58
Project NamcIN
42 Greatlands
Collected Date/time
06/302006 11:50
Client Sample ID
42 Grcatlands
Received Date/fline
06/302006 13:20
Matrix
Drinking Water
Technical Director
Stephen C. Ede
Sample Remarks:
Allowable
Prep
Analysis
pyu,neter
Results PQL Units Method Container ID Limits
Date
Date Init
Waters Department
Nitratc-N 3.26 0.100 mg/L GPA 353.2 D (<10)
Microbiology Laboratory
Total Coliform 0 col/100mL SM209222B A (<I)
06/30/06 ALR
06/30/06 TLF
1
§
coo
§�k§mA
�
}
{
E
0,
(
\[(
\f
°§((
-�:*kl
.0
ƒ-0
k
~�
m
n t
§ §
!
3
(
~ a
»
§
O ■■
k
§§§§j)j))j\49-
[ J[
(D\
O OO
E EE
§§
A
Zi
�j
00000
E
\q
000000000W
2\/n
=m#|
2\(g
M&cn
1
§
coo
§�k§mA
�
}
{
E
0,
(
\[(
\f
n-0r-raR
-�:*kl
.0
ƒ-0
k
~�
m
n t
§ §
12
~ a
»
§
O ■■
k
§§§§j)j))j\49-
[ J[
O OO
E EE
1
k
\
§
/
10
i
■
§
/
❑
2
0
»
❑
/
CL
f
/
❑
(
k
E
coo
§�k§mA
C
(
\[(
\f
%((
E@lw�r–=�O
§§§§j)j))j\49-
00000
\q
000000000W
M&cn
'
in
;m§§E§e§�w%E£§
�&�
LP
0
'
/\
�m
Bkw§wN[(&
000000000»
f(
=r to
0000%\{9
1>1
t\
§%k{k
21
�AGl�Sokge�
&E
2m
$§
®
(
()
k
\
§
/
10
i
■
§
/
❑
2
0
»
❑
/
CL
f
/
❑
(
k
E
_ ... ._ � �-, -., .. ry... ..
i
3
A
r-.
MUNICIPALITY OF ANCHORAGE 05-113109
DEPARTMENT OF HEALTH & HUMAN SERVICES
DIVISION OF ENVIRONMENTAL SERVICES
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4744
Application Date 5-12-87
1. GENERAL INFORMATION (MUST BE COMPLETED PRIOR TO SUBMITTAL)
(a) Legal Description (include lot, block, subdivision, section, township, range)
Lot 4 Mock 2 Gteattand Est. *%
Location (address or directions)
Gteat2and Ct.
Ee tete-------- ----
(b) Property Owner Telephone: Home Business
Mailing Address UK
(c) Lending Institution Notthtand Mortgage Telephone UK
Mailing Address Eag.Le Rivet, AK. 99577
(d) Real Estate Company and Agent Romax A.ttn AA
Address Eagle Rivet, AK. 99577
Telephone 694-4200
(e) Mail the HAA to the following address: or: Check here ®, if hold for pick up.
List contact person and day phone number below.
17034 Eagle River Loop Road No. 204
Eagle River, Alaska 99577
2. TYPE OF RESIDENCE
Single -Family 5l
Number of Bedrooms _
3. WATER SUPPLY
Individual Well 1� Community ❑ Public ❑
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsite ® Public ❑ Community ❑ Holding Tank ❑
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page 1 of 2 72-02e (Rev s s6) Front
5. ' ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on
the date of this inspection.
Name of Firm S & 5 ENGINEERING Telephone
Address 17034 Eagle River Loop Road No. 204
Date
Eagle River, Alaska 9577
6. DHHS APPROVAL
Approved for bedrooms by 'Q' �°'"6'''�' Date
Approved Disapproved Conditional
Terms of Conditional Approval
CAUTION
.Wiwig♦
f yY•f�iG
p
:Ti latil .3 � ,f"ti�:S
S— 2 -4, -2:7 -
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval
certificates based only upon the representations given in paragraph 5 above by an independent professional engineer
registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in
order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data
before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
Page 2 of 2 72-025 rBev 8i86) Back
tPP�`C� 01A gICIPA ITY OF ANCHORAGE (MOA)
R THORITY APPROVAL (HAA)
lnV�p O??'t4tON CHECKLIST - FEBRUARY 1984
`RO n C. 19161 264-4744
J �D Legal Description: L_'Z
A. WELL DATA
1z c_
Well Classification S. F If A, B, C, D.E.C. Approved (Y/N) A//_'A
Well Log Present &N) Date Completed (5 'Z3 - YeB Yield"
Total Depth / 51, Cased to Depth of Grouting �—
Static Water Level / Sy- Pump Set At V A,
Casing Height Above Ground —
Electrical Wiring in Conduit (#/N)
Separation Distances from Well:
Zr� Sanitary Seal on Casing (y91\1)
Depression Around Wellhead (Y&
To Septic/Holding Tank on Lot /d ; On Adjoining Lots Dov /f
To Nearest Edge of Absorption Field on Lot Z! r ; On Adjoining Lots
To Nearest Public Sewer Line To Nearest Public Sewer
Cleanout/Manhole � To Nearest Sewer Service Line on Lot S 1
Water Sample Collected by Date
Water Sample Test Results S Ai F(-�- T t2 (A7 1` C -O
Comments -Y- l,f�_c_L� FLLi o).r S - /S - S y- 'F C1 2 A, F� 4 S
B. SEPTIC/HOLDING TANK DATA
Date Installed `/ -/ rf - Size / ZSR No. of Compartments Z
Standpipes &N) Air -tight Caps(G)N) Foundation Cleanout/N)
Depression over Tank (Y& Date Last Pumped
Pumping/Maintenance Contract on File (Y/N) N?A_ ;for "JZA
Holding Tank High -Water Alarm (Y/N) 1\11A Temporary Holding Tank Permit (Y/N)
Separation Distances from Septic/Holding Tank:
To Water -Supply Well / oL To Building Foundation Sv
To Property Line 3 To Disposal Field
To Water Main/Service Line f p14 To Stream, Pond, Lake, or Major Drainage
Course
CommentsaF R S nn PI e�
S� gra -oz.Z_
Page 1 of 2
72-026 Mev. 8/86) Front
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata / ZS -0/oiz
Date Installed
Width of Field 3 01
— Type of System Design
Length of Field 68
Depth of Field
Gravel Bed Thickness
/ Com• S,
S
Square Feet of Absorption Area Standpipes Present/N)
Depression over Field (YCNP,,- Date of Last Adequacy Test
Results of Last Adequacy Test 514 / -Wf- /1 ae X'_ �� 3 32 -
Separation Distance from Absorption Field
, - 2 2 -3 q
To Water -Supply Well z To Property Line 7�7
To Building Foundation To Existing or Abandoned System on
Lot h/( ; On Adjoining Lots �y/_�
To Water Main/Service Line /b % To Cutbank (if present) Kt/(4
To Stream/Pond/Lake/or Major Drainage Course 'AZIA
To Driveway, Parking Area, or Vehicle Storage Area 35
Comments
D. LIFT STATION
Date Installed
Dimensions
Size in Gallons Manhole/Access (Y/N)
"Pump On" Level at A "Pump Off' Level at
High Water Alarm Level at Vent (Y/N)
Tested for
Electrical Codes (Y/N)
Comments
" Check Permitted Bedroom Rating Against HAA Request "
Pumping Cycles during Adequacy Test. Meets MOA
I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
S & 5 ENGINEERING �j 2z16-2
Sig 4 Eagle Rtier Loa M, a_.A�1_Ne. 2041 Date
CoofflolplFiver, Alaska 99577 MOA No.
Receipt No.
Date of Payment
Amount: $yL'0 0D jrs SLfal
Page 2 of 2
72-026 (Rev 8186) Back
�'Akw
0
CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC
5633 B STREET ANCHORAGE, ALASKA 99518 TELEPHONE (907) 562-2343
FEDERAL TAX ID # 92-0040440
LABORATORIES
u L I t
I 1"n'
'T4
r Ll;
5. LEGAL DESCRIPTION
DATE RECEIVED
INSPECTION APPOINTMENTS
I 1
2 / CA C r�nlyd S�sa leS S'�� ,v/siati
TIME
TIME
TIME
DATE
DATE
DATE
17:1 One V Four O Other
1�.
INSPECTOR
INSPECTOR -
INSPECTPIR
MUNICIPALITY OF ANCHORAGE MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DEPT. Gi= `•!-! 11
825 L Street - Anchorage, Alaska 99501 ENVIRON,0-L-11;'.'- '. - -CTION
•
ENVIRONMENTAL SANITATION DIVISION�,jiAYOu 0 3 i�
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWR3kUdIV fiD
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTYOWNER
PHONE
Mv.r -Creol A
-
MAI LING ADDRESS
60 Clv IAK 1A IASkA 49SG'7
PROPERTY RESIDENT (If different from above)
PHONE
13K. 2 %reA+lnly(A CIrd 0- (ir. 'Pe�ev'vQpeevl. Q
�'�tS�
2. BUYER
PHONE
MAILING ADDRESS
3. LENDING INSTITUTION
PHONE
MAILING ADDRESS
4.-REALTOR/AGENT - -
PHONE
MAILING ADDRESS -
5. LEGAL DESCRIPTION
•
L -d f 14 Q 1 oc-k
I 1
2 / CA C r�nlyd S�sa leS S'�� ,v/siati
STREET LOCATION
CareA+bk�c� CtvleC,e-
e4-evs ('ve -eK �•
6. TYPE OF RESIDENCE
NUMBER OF,BEDROOMS
17:1 One V Four O Other
10/ SINGLE FAMILY
0 Two 0 Five
E__1 MULTIPLE FAMILY
O Three 0 Six
7. WATER SUPPLY
[V INDIVIDUAL*
* ATTACH WELL LOG. A well log is required for all wells drilled
O COMMUNITY
since June 1975. For wells drilled prior to that date, give well
O PUBLIC UTILITY
depth (attach log if available.)
8. SEWAGE DISPOSAL SYSTEM
-
INDIVIDUAL/ON-SITE**
YEAR ON-SITE SYSTEM WAS INSTALLED.
O PUBLIC UTILITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. 6/7 9)6 �J
A /P/ k_ c_ it „ r
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE
❑ SINGLE FAMILY
❑ MULTIPLE FAMILY
NUMBER OF BEDROOMS
❑ ONE ❑ THREE ❑
❑ TWO ❑ FOUR ❑
FIVE ❑ OTHER
SIX
2. WATER SUPPLY
❑ INDIVIDUAL
❑ COMMUNITY
❑ PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM
❑INDIVIDUAL/ON-SITE
❑PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DATEINSTALLED
—
INSTALLER
❑Septic Tank or ❑ Holding Tank
Size: I a S_' If Tank is homemade
give dimensions:
SOILS RATING
�S
TYPE OF TANK
MANUFACTURER
TOTAL ABSORPTION AREA
MATERIAL
4. DISTANCES
WELL TO:
Septic/Holding Tank
Absorption Area
Sewer Line
Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS
\at,S
❑ APPROVED FOR BEDROOMS
,1❑_CONDITIONAL APPROVAL (letter must accompany certificate)
Lam'DISAPPROVED
DATE rY c
BY (
P�
2
Andnc "�e
May 23, 1980
825 "L" STREET
ANCHORAGE, ALASKA 99501
(907)264-4111
GEORGE M. SULLIVAN,
MAYOR
DEPART HENT OF HEALTH AND ENVIRONMENTAL PROTECTION
Manfred A. Colley
Post Office Box 608
Chugiak, Alaska 99567
Subject: Lot 4 Block 2 Greatland Estates Subdivision
Approval for your individual sewer and water facilities
can not be granted until the following items have been
completed:
(1) The water analysis report be delivered to this
department from Chem Lab, 5633 B Street, for
our review.
(2) The top of the well casing sealed with a sanitary
seal so that it is air tight.
(3) The septic tank pumped with a receipt submitted to
this department.
Please notify this department for a reinspection of the
well when it has been corrected. If there are any further
questions, please call this office at 264-4720.
Sincerely,
Robert C. Pratt, R.S.
Associate Specialist
RCP/ljw
-Tu
r
5. LEGAL DESCRIPTION f� 1
L �` 9 G I'f'Al LAA
MUNICIPALITY OF ANCHORAGE I `
DEPARTMENT OF HEALTH & ENVIRONMENTAL PR6Trt6TI6N
825 L Street - Anchorage, Alaska 99501
•
ENVIRONMENTAL ENGINEERING DIVISION
Telephone 264-4720
REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES
DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing.
1. PROPERTYOWNER
HAl'j V— ,
PHONE
MAILING ADDRESS
P.C.(4oq� LIQ (jkK AK. q '7
PROPERTY RESIDENT (If different from above)
PHONE
L' -I aI 6 ,4I LAwA 114tes- S�(�. 7e}ev,s CreekQKt
❑ Two ❑ Five
2. BUYER
PHONE
{�
r�t A P1 t v� e. A. C' D I
MAILING ADDRESS
A /r
3. LENDING INSTITUTION
� T AT r e+ Q v, iv .r A C r o c;,4 17 YU
PHONE
MAILING ADDRESS `
4. REALTOR/AGENT
PHONE
MAILING ADDRESS
5. LEGAL DESCRIPTION f� 1
L �` 9 G I'f'Al LAA
iT 1 - �+ j I /� ,
4Ates LAI CIV (e4err
x
i. J,V� (`FN� -'Cit .i, \ve
STREET LOCATION j j
GrP LAvucl e t
(�
Dr
A� 1V
6. TYPE OF RESIDENCE
NUMBER OF BEDROO S
Vo"SINGLE FAMILY
❑ One Four ❑ Other
❑ Two ❑ Five
❑ MULTIPLE FAMILY
❑ Three ❑ Six
7. WATER SUP LY
INDIVIDUAL*
* ATTACH WELL LOG. A well log is required for all wells drilled
❑ COMMUNITY
since June 1975. For wells drilled priort that date, give well
E]PUBLIC UTILITY
depth (attach log if available.) 17 4
8. SEWAGE DISPOSAL SYSTEM
-q
`*If individual/on-site, give installation date
INDIVIDUAL/ON-SITE**
If system is over two (2) years old an adequacy test is required
EJ PUBLIC UTILITY
by this Department.
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010(3/78)
1<' 4 kl,
THIS SIDE FOR OFFICIAL USE ONLY
INSPECTION APPOINTMENTS
DATE RECEIVED
TIME
TIME
TIME
DATE
DATE
DATE
INSPECTOR
INSPECTOR
INSPECTOR
DIRECTIONS:
1. TYPE OF RESIDENCE
Eg' SINGLE FAMILY
❑ MULTIPLE FAMILY
NUMBER OF BEDROOMS
❑ ONE ❑ THREE ❑ FIVE ❑ OTHER
❑ TWO ❑ FOUR ❑ SIX
2. WATER SUPPLY
LL�' INDIVIDUAL
❑ COMMUNITY
❑ PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM
EgtNDIVIDUAL/ON -SITE
❑PUBL-IC UTILITY
Connection Verified
PERMIT NUMBER
DATE INSTALLED
INSTALLER
❑Septic Tank or ❑ Holding Tank
Size: /(;Sfl If Tank is homemade
give dimensions:
SOILS RATING
1 -).S
TYPE OF TANK
MANUFACTURE
TOTAL ABSORPTION AREA -
MATERIAL
4. DISTANCES
WELL TO:
Septic/Holding Tank
Absorption Area
Sewer Line
Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS t-'_
w
❑ APPROVED FOR BEDROOMS
47`CONDITIONAL APPROVAL (letter must accompany certificate)
❑ DISAPPROVED
DATE
1����'• 0)
BY (Title)
LEGAL DESCRIPTION
72-010 (Rev. 3/78)
January 4, 1978
Fred Colley
440 North Klevin
Anchorage, Alaska 99504
Subject: Lot 4 Block 2 Great Land Estates subdivision
Permit #77766
A permit issued by this department for well and/or sewer
sytem has expired.
Permits are issued on a calendar year basis, as stated on
the permit, by authority of municipal ordinancee
if you have drilled the well, a well log should be sent
to this department to document the installation date.
If there are any further questions, please contact this
office at 264®4720.
Sincerely,
Health and Environmental Protection
sewer and Water Section