Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T12N R3W SEC 25 W2 SW4 NW4 NE4
TI:2N R3W Sec 25 W25w4NW4 #017 -41 1 -01 www.sullivanwaterwells.com Pump Installation Log Well Drilling Permit Number: SW Date of Issue Parcel Identification Number: Legal Description Property Owner Name & Address T12N R3W Sec 25 W2SW4NW4NE4 Bob Day 12690 Jeanne Road Anchorage, AK 99516 Pump Installation Date: 9-29-21 Pump Intake Depth Below Top of Well Casing: 130 feet Pump manufacturer’s Name: F&W Pump Model: 4F11P05301S Pump Size: 1/2 hp Pitless Adapter Burial Depth: 10 feet Pitless Adapter Installer: Unknown Disinfected Upon Completion? yes no Method of Disinfection: Chlorine 50 PPM Comments: Pitless Manufacturer: Unknown Pump Installers Name: Sullivan Water Wells Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. June 10, 2002 Municipality of Anchorage Gcorge P. 117uerch, .Akiyor Building Safety Diiision P.O. Box 196650 • 4700 S.. Braew Strcct Anchorage, Alaska 99519-6650 • (907) 343-8301 h ttp://������•.ci.anchora;c.ak.us Robert A. Day & Bonnie Harman 8212 Sea Cliff St. Anchorage AK 99502 Subject: On -Site Water and/or Wastewater Permit. Permit Number: SW010278 �Lggal Description:-T12N RM.Section'25 W2 SW4 NW4 NE41 Dear Robert A. Day & Bonnie Harman: An On -Site Water/Wastewater Permit, number SW010278, issued by this office for a single-family system, will expire on July 30, 2002. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed undei this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $100.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $400.00 for a wastewater permit and $150.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincer Jim rocs, P.E. M ager On -Site Water and Wastewater Program Enc: Copy of permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Permit Number: SWO10278 1iV�^g3.1`tt.N i Design Engineer: 0014 Anderson Engineering Owner Name: Robert A. Day & Bonie Harman Owner Address: 8212 Sea Cliff St. Anchorage , AK 99502- 'p/y ;rA,111 Date Issued: Jul 30, 2001 Expiration Date: Jul 30, 2002 ParcelID: 017411-01 Site Address: Lot Size: 217800 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: Z Disposal Field a Septic Tank Holding Tank [] Privy All construction must be in accordance with: 1. The attached approved design. 0 Private Well [I Water Storage 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. AtQ4 I Fl Ar� or I J9 Received By: Issued By: Date: Date: 4- 9/13 J10 / .01 0% Municipality of Anchorage • Development. Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 017.411.01 Permit Number SW 0/0 2 78 Property owner(s) Robert A. Day and Bonnie Harman Day phone 243.7300 Mailing address (1) 8212 Sea Cliff Street Anchorage, AK 99502 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) T12NR3WSEC25W112SW114NW114NE114 Legal description (Section, Township & Range) Lot Size 217,800 SF Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Four Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: �gl4n Date of Payment: 't'aC";s Receipt Number:��ac (Rev. 12/00) Waiver Fees: Date of Payment: Receipt Number: ANDERSON;ENGINEERING P.O.: BOX 240773;; ANCHORAGE; AK 99524 ? . . 522=77.73' _ ..;' , 522-6779 (FAX) MEMORANDUM DATE: September 13, 2001 TO: Dan Roth FROM: Mike Anderson, P.E.YV�JtA-., SUBJECT: W1/2, NE1/4, NW1/4, SW114, Section 25, T12N, R3W Septic System Construction Permit No. SWO10278 I recently inspected the subject lot to review the proposed location of the new septic system. I noted some surface water approximately 90' from the designed location for the new system and also found the system to be a substantial distance from the proposed house. We then attempted to find a location for the new system, which was closer to the new house. Two test holes were completed in June near the house location. Two additional test holes were completed on September 8, to determine the depth of the bedrock in the area of the revised location for the new system. Test holes completed in June revealed no bedrock. Those recently completed indicated bedrock at 13' near the west end of the revised location and at 10' nearly 80' east of that location. These holes are identified on the attached Site Plan as THA and THB. We have revised the septic system design to include 2-50' long by 5' wide by 3' effective depth absorption trenches. The total depth of the trenches will be 4' below the surface to provide at least 6' separation from bedrock. All indications are this distance will be much greater than 6'. A Zabel Flow Splitter Valve will be installed to insure even flow of effluent to each trench. We have used an application rate of .7 gallons per square foot per day as an average between the percolation tests completed. More than 90% of the new trenches are within the 30' radius where the percolation rate was determined to be 14.1 minutes per inch. We are confident an application rate of .7 is very conservative for this system. The well location has been moved further to the south. Surveyed measurements to surrounding septic systems indicates the closest system is more than 157' from the location shown. We hereby request the permit issued for the construction of a well and septic system on this lot be revised to include the attached Site Plan. Please let me know if you have any questions or additional information is required. July 23, 2001 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: T12NR3WSEC25W1/2SW1/4NW1/4NE1/4 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of the subject 5 -acre parcel intends to construct a four-bedroom house on the property, which may eventually become a bed and breakfast operation. We are therefore applying for a permit to construct a well and septic system on the lot to serve the new home. The attached Site Plan and backup .documentation identify the location and configuration of the new septic system and the parameters used in the design. Also identified on the plans is the location of the new well and the 150' protective radius along with the location of the test holes. Existing drainage patterns are shown and will not be altered by the development of the lot. Two separate engineers have placed several test holes near the location of the new absorption trench and the alternate site in the past several years. These holes indicate silty gravel and sand with some cobbles. Percolation tests in the material resulted in rates between 1 and 7 minutes per inch. No groundwater was found during placement of the test holes and none was noted during the monitoring period. We are therefore proposing to place a 5' wide absorption trench with V of gravel beneath the distribution pipe. The total depth of the trench will be approximately 5' Mounding will be required over the trench to provide the minimum 3' of protective cover. The ground surface on the lot slopes as shown on the attached Site Plan with varying grades from northeast to southwest. The new absorption trench will be constructed on a fairly flat surface in conformance with Municipal requirements and parallel to ground contours where possible. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system,'if.constructed as -designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. NE1/4NW1/4SW1/4W1/2SEC25 ' July 23, 2001 Page Two 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, vwaz" Michael E. Anderson, P.E. Attachments /+,099 m `10.0 N JOB // IO 96 � O �o a .�- �O0 ~ • WN r 0 bk cab 6s 52 TOE &4NK -�- /x=,099 m £`t.0 H GVOY 7V3HOIN NEI/4, NW1/4, SW1/4, W1/2, SECTION 25, T12N, R3W DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Perc. Rate: 14 - 20 Min./Inch 1,250 Gallon Septic Tank Application Rate: .7 GPD/SF 3' Drainfield Rock 4 Bedrooms X 150 GPD /.7 GPD/SF = 857 SF of Absorption Area 857 SF/5 LF (Width)'.58 (Red. Factor) = 99 LF Trench Length Therefore: Construct Two 50' Long X 5' Wide X 3' Effective Depth Absorption Trenches. Flowline Elevation in Trenches to be V Below Original Ground Surface. Total Depth to be 4' Below Existing Ground. Zabel Flow Splitter Valve Must Be Placed to Assure Even Distribution of Effluent to Each Trench. All Components of the Septic System to be Outside the 150' Well Radii. Mound Over Trench to Provide a Minimum of 3' of Cover or Provide 2" of Direct Bury Insulation and 2' of Cover. 2" Insulation & 2' Com or Geotektile' Fabric & 3' 6" " PVC ASTM D3034 3' Drainfield Rock 5' TYPICAL WIDE TRENCH SECTION <4� OF qQtv (NO SCALE) .`��....... C _QSa34 NOTE: Grade Area Over Trench to Drain Away. ��, 49� Minimum 6 Separation From Bedrock. Minimum 4' Separation From Groundwater. •• •••'• ""' "' "'�'" Minimum 100' Separation From Wells in the Area. 0.0... ••••••••--•• ' MICHAEL E. ANDERSCP4 �... �' • CE -4331 4�A.0 _ 1 Municipality of anchorage l DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR: M I � I • LV ,l- 5 w LEGAL DESCRIPTION: 6. T- 72 1 2 3 4 5 6 7 8 c 1( (+yj rld GM 14 15 16 0 17 1 r" •4� 8 ..t 19- �PAICHAEL E. ANDERSON 0 CE -4331 P�ic,NG'itD�Ei 'i-5{6EECt�� •ct 4 • 'i; � s ✓ `G 1' . DATE PERFORME .L ip, Range, Section: SLOPE WAS GROUND WATER /1 ENCOUNTERED? �V S L IF YES, AT WHAT 0 DEPTH? P E Be* to Wrier Alter mnnitarina? -fC Q Q Date: SITE PLAN I Gross Ti me Depth to Time Water mill .rI . • . •' 20 (� e4 p •' • • • • • •' •�� PERCOLATION RATE �(minutesnnch)) P-EERC HOLE DIAMETER TEST RUN BETWEEN FT AND ` FT COMMENTS r_ PERFORMED BY-%w-11tom,-�gT� ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELW 72-008 (Rev. 4185) CERTIFY THAT THIS TEST WAS PERFORMED IN IN EFFECT ON HIS DATE. DATE: L • Municipality of Anchorage y`7t±4DEPARTMENT OF HEALTH & HUMAN SERVICES L1 825 "L" Street, Anchorage, Alaska 99502-0650 " [ r SOILS LOG — PERCOLATION TEST PERFORMED FOR: Mi f eP� (� � 2 z�5w LEGAL DESCRIPTION: t DEPTH 1 (FEET) p� Y'ow►'� S � � �' 2 3 -1 N 4- 5- 6- 7 5 67 8- 9- b. 9 .a 10 11- 12 1 12 13 14 15 16 17 18 19 t � (�� 5•a��Y Cede( MM •OF. q,��t • 49?H ` MICFIPEL E. 4�JCfGS'vN •. �,'.• CE -4381 •: cw w -Ilk DATE PERFORMEb: =»•� ownship, Range. Section: SLOPE %-4 WAS GROUND WATER ENCOUNTERED? ' S L IF YES, AT WHAT O DEPTH? P E Depth to wrier After S 1� \) Motutorinp? `Da Reading Date Gross Time S�O Net Depth to Net Time Water Drop 2.. -Z- 20Qtkzd OFESS �®v PERCOLATION RATE -'"-� tminutesnnCh) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND FT COMMENTS n r PERFORMED BY: ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT 72-008 (Rev. 4185) CERTIFY THAT THIS TEST WAS PERFORMED IN THIS DATE. DATE: 4—,- 1-4- �z Gl 1IMEMSEAL) • f Municipality of Anchorage •4 s� , J ♦ DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST , .,�, , s = .f • PERFORMED FOR: ' `v ^� •� DATE PERFORMED: •�' 5 �/¢ f N w 1¢ f LEGAL DESCRIPTION: k��/�'`w I_ 1, Township, Range, Section: DEPTH � ✓1 �I fG�SLOPE SITE PLAN 9�� I 5 1- /7 2- 3 3 4 5 6 8 9 10 11 12 13 14 G. ra GM 15 ,.,�,�e.C'.a ,. �• OF16- q��CCC 9TH 4 .v ' 17 © ...�,: � 18 Idta,-.MICHAEL E. AADc{iCGN CE - 4381 .•'� '� 19 „► C WAS GROUND WATER A J/(� ENCOUNTERED? � V �� s IF YES, AT WHAT L DEPTH? P E Depth to Water After /�D - — j4-1 MaWtoring? " � Date i k r— Depth to ==ITime Water - _-150 1 a RIPA����JU��� 20 a ti b%'O1�`�@If PERCOLATION RATE :jf (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN FT AND / F7 COMMENTS PERFORMED BY. v • .,/ v"' "` 1 CERTIFY THAT THIS TEST WA PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELI S IN EFFECT ON THIS DATE. DATE:" �f 72-008 (Rev. 4/85) M COH LTWO 040NEER3 P.O. BOX 111349 AMO<RACE. ALAUA HSt1-1349 SOILS Loo-PMc TM TEST TEST.HOLE 1 CLIENT: MR. KEIAN CASSIDY DATE_ PERFORMED: W 1/2. SW 1/4. NW 1/4. NE 1/4 CF LEGAL DESCRIPTICN: T12N. R3w, SEC25 S.M. W.O.: 94175 DARK BROWN ORGANIC SILT 1 DRY. WITH ROOTS BROWN GRAVELLY SILTY SAND 2 of FROZEN GRAVEL TO 1 1/2" 3 / OCCASIONAL BOLDER 12" TO 24" i„i. A VERY DENSE • 0 5 /o/ / 7 /o 4/ 'b.�( , BROWN SILTY SANDY GRAVEL VERY DENSE ROCK -FRACTURED dr (2" TO 4') MOIST SLOPE SITE PLAN WAS GROUND WATER 10 o ° ENCOUNTERED ? NONE L I I I { I I ! 11 / I 1 1 1 1 1 1 1 1.4-1 P 1/0 4E I I I I I I 1 , i 0/1 12 / ., / otos nWE I NO Ina / °/o / MCT 04W 13 1 6-11-93 9:4d/2:52.30i4':30• 19:27/10:01:471 4a J.- i 14 0 / �•!,&x,I,ws BEDROCKzOF15 ' 6-11-93 4':47' ,.- I 4' I .00 I .��.7 Vo I 6-11-93 w.-JGA*aLul f.�:...rd 1 17 :MICHAEL E. ANN ERSCN • 4Q, o •. CE - 4381•�� Ut. .••��,� l f k q"P cE.v,0'' PERCOLATION RAT_: 0 g (MINUTES/!NCci.) PERCHGL_ DIAMETER:g. TEST RUN EETWE_N: 5' -T. ANC - 9CADOC CAM otos nWE I NO Ina oE+,'MA' MCT 04W � PCRr-"r 1 6-11-93 9:4d/2:52.30i4':30• 19:27/10:01:471 4a J.- i 6• 0.75 2 ' 6-11-93 4':47' ,.- I 4' I .00 I 3 I 6-11-93 w.-JGA*aLul 4': JJ• 445 in- ! 6• 0.76 I 1 I I i r C:0MM:N7S: T=S7!7 DUG USING BACKHOE. ?ERFJRMEo BY: or_ NIGH ()AT-: 6-11-94 .7�%S--- s ' • ON CON3LLTWO ENGINEER, P.O. BOX 111349 AM04MAM ALASXA Y9311-1349 SOILS LOO -PERCOLATION TEST TEST HOLE 2 CLIENT:M=c. K=VIN CASSIDY --11-93 X c c W 1/2. SW 1/4. NW 1/4, NE 1/4 OF Da" P�R="R""_.,. :.,� •. LEGAL DESCRIPTION: Tl2N, R3W, SEC25 S.M. W.0.: 94175 ., DARK BROWN ORGANIC SILT, W/ ROOTS 2' LIGHT BROWN SILTY SAND W/ GRAVEL MOIST • :,r� COLD, POSSIBLY FROZEN, MED. DENSE 3 ( 'u 14 ©� ,.: 49TH — . BROWN SANDY W/ GRAVEL ROCK 5 r Q ROUNDED TO 4 --SOIL COLD ••�� m 18 r BUT NOT FROZEN, MOIST. MED. DENSE 6-11-93 Il�;i5— 3•:47' ss' -49' S. 0.63 1 7 i•f s':39• ! s4• -+e' I e` 0.94 S I 6-1t-93 i,1: �•: ts- S':3" ! S4' -•e' I ,. I 9. !0 SILTY GRAVELLY SAND. DENSE. 9 6' MOIST, BED ROCK AT 10' SLOPE SITE PLAN 10 WAS GROUND WATER - S I I I I I I I ENCOUNTERED ? NONE L ' o I I I ! i1 p 12 E !ills II. 13 mm.c 0� +' 14 ©� ,.: 49TH — . MICHAEL E. ANDERSON Q 17��' J,'• Cf: - 4331 fes'•• 3.:40. ••�� m 18 r 0.61 6-11-93 Il�;i5— 3•:47' ss' -49' S. 0.63 1 mm.c 0.7E taoss ,WC wy ,trc 00" or Z 5-11-93 3.:40. .ys•-49' 6• 0.61 6-11-93 Il�;i5— 3•:47' ss' -49' S. 0.63 1 • e -,t-9. 1,1:23:10- s':39• ! s4• -+e' I e` 0.94 S I 6-1t-93 i,1: �•: ts- S':3" ! S4' -•e' I I 9. !0 6' 0.93 6 I 6-11-93 =':''• 54'—.g' 1 ' itt.�.< ! 6• 0.96 PERCOLATION RATE: 1.0 (NINUTESj'NCn.) P=RC=CL= DIAMETER: = TEST RUN 5ETWE=N: s'—S" -- .AND - —:." -- C.^.MMcV'S' TES PIT DL.0 USING SACKHCE. PERFORMED BY: DEE HIGH. DAT- 6-11-94 i 7SCS_= Z ' • DH CON3ULTMq ENOWEFRS P.O. BOX 111349 AUOCPACE. ALASKA 90311-1349 SOILS LOO -PERCOLATION TEST TEST HOLE 3 CLIENT:MR. KEVIN CASSIDY DAM P_R=ORM_D: _•'_ W 1/2. SW 1/4. NW 1/4. NE 1/4 OF LEGAL DESCRIPTION: _ T12N, R3W, SEC25 S.M. W p . 94175 ^•. ',,-%I ORGANIC SILT. ROOT MAT 1 2 4 • �: '�' BROWN SANDY GRAVEL 5 : /; ./ W\ SOME SILT 7 F. 9 10 11 12 13 14 15 16 17 SLOPE M V . � S;TE PLAN WAS GROUND WATER S• ! I I I I ENCOUNTERED ? NONE L 0 P I!IIII E tl b RCAO MC DA:C CROSS mum , MET MAC 1 00-Th 1� ! MET ORCr �CRC.AATC 4�ra@ .. u Q �• € cs (/) •' • • "fir ' �-✓ •. ! b� ! 1 � I d•Ar ... 1 MICHAEL E. ANDERSCN : A0 1 ! I ! ! ' CE - 4381AW • � � I 7 • � -: �� 1pROfESS1�N .®v 1 i I PERCOLATION RAT_ (MIND 1tS/'NC:-.) PERCHCL_ DIAM_-=R TEST RUN @E-wE_x: FT. AND CCMMEN'S• SOILS LOGGED BY CLIENT OW CON3ULTMIG ENOINE£RB ,,.•" P.O. BOx 111.349 ANO<RAC'L AL%WA 94511-1549 - �• SOILS LOG-P£RCOLAnON TEST TEST HOLE 4 r CUENT:MR. K_XAN CASSIDY CATE ?:RFCRmr-0: E-12-9= 'F }•• �, r.1'j r �!^.7 . 'i.. W 1/2• SW 1/4• NW 1/4, NE 1/4 OF �3.Y•• LEGAL DESCRIPTION: T12N, R3W, SEC25 S.M. w.0,: 94175 12 13 14 ``'OF p 1 TTI I I I E II ORGANIC SILT, ROOT MAT l C:; T` 1 ! '� '•' �: �s 4' • •• 44,41• 17 SLOPE SITE PLAN .' �•' ^' ' sf.• CE - 4381 •:���AV I I i I I 3 ESSO Pad@v 4 ;.. SANDY GRAVEL T 5 I I I I TI SILTY, GRAVELY SAND 7 '4 ,. ./•,:� SAND w/ GRAVEL SOME SILT I 8 FIR - '�j'l�♦ SAND COARSE II I I 9 i IIIII WAS GROUND WATER S 10 ENCOUNTERED ? NONE � f 12 13 14 ``'OF p 1 TTI I I I E II Illilil l C:; T` 1 ! '� '•' �: �s 4' • •• 44,41• 17 �, • MICHAEL E. ANDERSON . � o ��� t ' sf.• CE - 4381 •:���AV Aw ESSO Pad@v o V I I I p 1 TTI I I I E II Illilil ASC 1 cArE atm ,mc at »wc mo- .otuA= I I 1 1 P:RCvLATION RAT--(MINUTESjINC-.j PERCHCL_ 0I.Am _? 2 1 i_ST RUN oETWEZ`4 Fi. ANl':_ _-- C^•MM-'.NTS: =31LS LOGCcD BY KEVIN CASS;CY. OH CONBULTMKI ENQ&EI R3 P.O. BOX 111349 AACHCRACL ALASKA 90511-1349 SOILS LOG4M3W "T10N TEST TEST HOLE 5 MR. KEViN CASSIDY �1A4QL" -' v, CLIENT. DATE PERFORMED: 6 -9- W 1/2. SW 1/4. NW 1/4. NE 1/4 OF LEGAL DESCRIPTION: T12N, R3W, SEC25 S.M. W.O.: 94175 � ��'a' l , 1 2 3 4 5 6 7 8 9 10 11 12 13 ORGANIC SILTS W/ ROOTS DRY, BROWN SANDY GRAVEL SILTY SANDY GRAVEL MOIST, PLASTIC SANDY GRAVEL, TRACE OF SILT SANDY GRAVEL. SLIGHTLY MOIST, COBBLES SILT/CLAY SANDY GRAVEL. VERY MOIST, SATURATED SLOPE SITE PLAN A,: WAS GROUND WATER S I ! ( ! ( ! I I ENCOUNTERED ? NONE L I( I I ( I I ° ►!I lII�I! P E i { I ' 14 6AIE MM t1Mt MET rME I OP rTM[w� MET OMP IOlC1tATE 1 l�,,'`S OF15 10 WN. 46•-54' 6• 4 A 2 6-12-93 10 MW. ay c).* ' `'A 6- 1.67 3 d-12-93 1• j 10 YIN. I 46'-54• 6' 1.67 i 1 7 6-12-93 !. ! 10 WIN. MICHAEL E. ANDERSCNN Ao6' fir. CE - 4331 .. . a 11 4W RcAaw0 • I 6AIE MM t1Mt MET rME I OP rTM[w� MET OMP IOlC1tATE 1 6-12-93 10 WN. 46•-54' 6• 1.67 2 6-12-93 10 MW. 48'-34• 6- 1.67 3 d-12-93 1• j 10 YIN. I 46'-54• 6' 1.67 i 4 6-12-93 !. ! 10 WIN. 46•-54' I I { I i PERCOLATION RATE 1.7 (MINUTES/INC`'.) ?ERCHOLE DIAMETER- 20 IAM_TE TEST RUN ScTOvEEN: 5'-0" AND 5'--" -- C,^•MMEN'S: P! I uUG USiNG SACKHOE PERFORMED BY: DE-- HIGH DATE: 6-12-94 Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For. Bob Day Date Performed: Legal Description: W1/2.NW1/4.NW1/4.SW1A Section 25 SLOPE SITE PLAN 1 r7 OG/01- 2 G10L 2 3 TESTHOLE NO RSE-1 4 5 1 GW/GM 6 7 8 9 10 11 12 Bottom of Hole 13 14 15 16 17 18 South Was Groundwater Encountered? No S If Yes, What Depth? L Depth to Water O After Monitoring None P Date: 9/10101 E See Site Plan MICHAEL E. ANDEMN CE- 4381 \' `, rr 6/14/01 �EE�ESS�OC�o'r' Reading Date Gross Time Net Time Depth To Water Net Drop 1 14 -Jun 2:56 1" 2 3:26 30 3.13" 2.13" 3 3:27 1" 4 3:57 30 3.13" 2.13" 5 3:58 1" 6 4:28 30 3.13" 2.13" Perc. Rate: 14.1 Min./Inch Perc. Hole Diameter. 6" 21 Test Run Between 5 Ft. and 5.5 Ft. Comments: Test Hole Presoaked Prior to Test. Performed By: Simon Evans. I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 9/13/01 Municipality of Anchorage Department of Health & Human Services 825 L Street, Anchorage, AK 99502-0650 SOILS LOG - PERCOLATION TEST Performed For: Bob Day Date Performed: Legal Description: W1/2.NW1/4.NW1/4.SW1/4 S ..tion 2 SLOPE SITE PLAN 1 2 3 4 OG/OL 5 GM 6 Depth To Water 7 1 10 11 12 South Was Groundwater Encountered? No S If Yes, What Depth? L Depth to Water O After Monitoring None P GW/GM Date: 9110/01 E Bottom of 13 Hole 14 15 16 17 18 See Site Plan •-Fe t4 �( h4JCHPEL E. ANDERSON ti v °� �'•, CE - 4381 �. 6/14/01: C e t R0F[SS�'V -- Reading Date Gross Time Net Time Depth To Water Net Drop 1 14 -Jun 3:00 .5" 2 3:30 30 2.13" 1.63" 3 3:31 .5" 4 4:01 30 2" 1.5" 5 4:02 .5" 6 4:32 30 2" 1.5" Perc. Rate: 20 Min./Inch Perc. Hole Diameter: 6" 21 Test Run Between 5 Ft. and 5.5 Ft. Comments: Test Hole Presoaked Prior to Test. Performed By: Simon Evans. I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 9/13101 Robert Day -8212 Seacliff St Anchorage, Alaska 99502 USA i Phone'240 7243 Fax 562 3050 Home Phone 243-7300 Email raday@gtci.net i September 20, 2001 To whom it may concern, -IRobert •Day -intend -to install -the septic system,components-at-our-building site -on Jeanne -Drive. The legal description for the property is T12N R3W SEC 25 W2 SW4 NW4 NE4 -I have obtained a permit to .perform the work from the municipality of Anchorage.( # SW010278 ),.I have Extensive experience operating heavy equipment including an excavator which I will be using to perform the work I will be renting the excavator from United Rentals on the Old Seward Hwy. Sincerely ,