HomeMy WebLinkAboutKNIK VIEW ESTATES BLK 3 LT 16Knik View Estates Block 3 Lot 16 #051-043-18 Municipality of Anchorage Pa~e Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. cLanchora{le.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW03031~ 12.. ! PID Number:. 051-481-31 Name: MM&M Contracting, Inc. WastewaterSystem: New Address: P.O. Box 670495 Chugiak, AK 99567 ABSORPTION FIELD Phone: Number of Bedrooms: 688-1236 Four {4) Deep Trench LEGAL DESCRIPTION Se,.ating: Tote, ~pth from orig~na, grade: .8 Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 3 16 Knik View Estates 2 Township: Range: Section: Fill added above original grade: Gravel Length: 1-2 Well: Public Water System c~-~ve~ width: Number of lines: J Distance between lines: 3 r,. 1 rt. rJ~$_~calion (Private, A, B. C): Total Depth: Cased Io: Total absorption area: Pipe Material: A rt. rt. 752 v,' ASTM 3034 PVC Driller: Date Drilled: Static Water Level: Installer:. ~ Date Installed: v,. MM&M Contracting, Inc. 8/27-28103 c,u rt. Ft. TANK SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. . [] Other:  Septic Absorption Lift Holding ~ublicJPdvateManufacturer; Capacity in Gallons: Tank Field Station Tank Sewer Line Anchorage Tank .1,250 MatenaI: ~ Number of Compartments: we,, ·200' ·200' N/A N/A ·25' Steel Two (2) Su,aceWaler>100' >100' N/A N/A ~ LIFT STATION - NONE ON LOT Lot IJne >5' 4' N/A N/A ~,e: ~,anutacturer: Gal. Voundation >5' · 10' N/A N/A ',,,mp on' level at: 'Pump Off' level at: I H,gh water alarm at: in.in. in. Curtain Drain None Noted Pump Uake& ~o~e, ~,e~,,nsp~,o.s pe,o..ed by: Remarks: BENCH MARK See Lot Line Waiver. Location and DescnpDon: Garage Slab Assumed Elevabon: 100.0 Ft. Engineer's Stamp Inspections performed by:_T.L. Kimbrough Dates: 1't 8~27~03 ~ .-'" 49th ~~~%~'~ 2nd 8/28/03 ~o' ~,C.*,L ~. ^,,~_~,SC. ~.' --' Department of Health and Human Services approval · ~: . .-~. · ..r,?,, No c£-438~ -*'~"~, Reviewed and approved by: ~j~"~ ~' /~'~/..,~~ate: Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW030121 Page 2 of 3 PID No. 051o043-18 / c4 ~TH 1 ,13 JA B S1 28.1 169.1 S2 35.0 170.8 C4 42.5 174.2 40.9 ~72.5 C5 46.1 142.1 NA.S PLA -BUILT ,,..~ SCALE I =40 LOT 28, BLOCK 3, KNIK VIEW ESTATES SUBDIVISION Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW030127 Page 3 of 3 PID No. 020-052-25 95,55 81.4 99,5 Dr'~zlnFleid Rock 35' (Tr,ench Length) PROFILE AS-BUILT Scale: 1' = 10' , H[CHA£1_ ~ ANi~ER'~DN No. CE-438t MUNICIPALITY OF ANCHORA GE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 9951g-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: May 08, 2003 Expiration Date: May 07, 2004 Permit Number: SW030t2t Legal Description:~.KNIK_VI EW,E ,STATES ' BLOCK 3 i LOT. 16' Design Engineer: 0014 Anderson Engineering Owner Name: MM & M CONTRACTING Owner Address: PO BOX 670495 Total Bedrooms: 4 CHUGIAK, A 99567- Parcel ID: 051-043-18 Site Address: NHN JUDD DRIVE Lot Size: 24620 SQ. FT. Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank r-~ Holding Tank [-~ Privy Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak, us (907) 343-7904 ON-SITE SEWERNVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D.O51-043-18 Permit Number SWO~ Property owner(s) MM&M Contractinq Mailing address (1) P.O. Box 670495 Chuqiak, AK 99567 Mailing address (2). Day phone 688.1236 .Zip Code Legal description (Lot, Block & Sub'd.) Lot 16, Block 3, Knik View Estates Subdivision Legal description (Section, Township & Range) Lot Size 24, ~' 2 0 Acres~]~ Number of Bedrooms Four (4) THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool [] Well Only [--~' [] Water Storage [] [] Jacuzzi [] [] Water Softening Unit [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev. 12/00) Waiver Fees: Date of Payment: Receipt Number: ANDERSON ENGINEERING' .. : ...-:i:P.O. Box 240773 : :. ~:':'..,. . - - 'ANCHORAGE, !AK 99524 . 522'7773 : '' 522~:67.79 (FAx) May1,2003 Municipality of Anchorage DeVelopment Services Department On-Site Water and Wastewater Program 4700 South Bragaw. Street Anchorage, AK 99519-6650 Subject: Lot 16, Block 3, Knik View Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 16, Block 3, Knik View Estates Subdivision intends to construct a four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the proposed home. The attached Site Plan and backup documentation identify the location and configuration of the new septic system and the parameters used in the design. Also identified on the plans are the location of the water service on the lot and the test hole locations. Existing drainage patterns are shown and will not be altered by the development of the lot. The test hole placed near the location of the proposed absorption trench indicated poorly graded silty sands with varying amounts of gravel. Percolation tests in the material resulted in rates of 6 minutes per inch. No groundwater was found during the placement of the test holes and none was noted during the monitoring period. We are therefore proposing to place a 47' long 3' wide by 8' effective depth absorption trench. The total depth of the trench will be 10'. The distribution pipe will be placed at 2' below the ground surface to provide sufficient drop from the septic tank to the absorption trench. Surface drainage patterns will be maintained after construction is complete. The ground surface on the lot slopes as shown on the attached Site Plan with a shallow slope near the proposed absorption trench. The new absorption trench will be constructed on a fairly fiat surface in conformance with Municipal requirements and parallel to ground contours where possible. All components of the new septic system will be constructed a minimum of 100' from the existing well on the lot. If the system is constructed in accordance with our design the following statements apply: Lot 16, Block 3, Knik View Estates May 1, 2003 ' Page Two o The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. .3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 12 '13 AREA MA SCALE 1" = 100' LOT 16, BLOCK 3 KNIK VIEW ESTATES *Alt. 2% Site TH 1 ® 1,250 Gallor Septic Tank Long x ~ 10% Effective Depth Absorption Trench .13 Four Bedroom Home +25% SITE PLAN SCALE 1" = 40' LOT 16, BLOCK 3, KNIK VIEW ESTATES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom House Deep Trench System Perc. Rate: 6 Min./Inch 1,250 Gallon Septic Tank Application Rate: .8 GPD/SF 8' Drainfield Rock 4 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 750 SF Absorption Area 750 SF/16 SF/LF = 46.9 LF Trench Length THEREFORE: Construct a 47' Long x 3' Wide x 8' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 2' Below Odginal Ground Surface. Total Depth to be 10' Below Existing Ground. Maintain 10' Separation From Water Service on Lot. Provide 3' of Cover Over Trench and 4' Over Septic Tank or Provide 2" Insulation and 2' of Cover. 6# 8~0" Natural Backfill ~ Geotextile / IFabric 4" Perforated · ,, C> -~_ PVC (Holes Down) -- Drainfield Rock TYPICAL DEEP TRENCH SECTION NOTE: Grade Are~ Over Trench to Drain Away. Minimum 6. Separation From Bedrock. Minimum 4 Separation From Groundwater. Minimum 100: Separation From Wells in the Area. Minimum 100 Sepa~tion From Sudace Water or Streams. I 2-- 3-- 5-- 6-- 7 8 9 18 PROJECT #: PERFORMED FOR: JVIUNICIPALITY OF ANCHORAGE DEPARTHENT OF HEALTH & HUHAN SERVICES 825 L STREET, ANCHORAGE, AK gg502-0605 SOILS LOG - PERCOLATION TEST H0319 PAUL MYERS / MM&M CONSTRUCTION DATE PERFORMED: /,/9103 LEGAL DESCRIPTION: LOT 16, BLOCK 3, KNIK VIEW SUBD. TEST HOLE # REDDISH ORGANIC SILTY-SANDS POORLY GRADED SILTY-SANDS SP 1 SLOPE < 2% SITE PLAN TH2 o o TH1 NO SCALE / SEE ASBUILT COIiMENTS: WAS GROUNDWATER ENCOUNTERED? IF YES, WHAT DEPTH? DEPTH OF WATER AFTER IVIONITORING: WELL GRADED DATE: SANDS W/GRAVELS SW - ~ :."' ,0. ,,-,,,, %.? NO S L O P None E /,/29/2003 <2% GROSS NET DEPTH OF NET READING DATE TIHE TIHE WATER DROP Sfarf /,/9/03 11:35 12.0" 1 12:05 30 ?.0" 5.0" Recharge 12:05 12.0" 2 12:35 30 ?.0" 5.0" Recharge 12:35 12.5" 3 13:05 30 ?.5" 5.0" PERC RATE: 6 MIN./INCH PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN 5.5 FT. AND 6.5 FT. NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST /,/29/2003 TEST PERFORHED BY: T.L. KIHBROUGH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND IVIUNICIPAL GUIDELINES ON THiS DATE: /*/29/2003 I 2 5 6-- 7 8 9-- Ill PROJECT #: PERFORMED FOR: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH ~ HUMAN SERVICES 825 L STREET, ANCHORAGE, AK gg502-0005 SOILS LOG - PERCOLATION TEST M0319 PAUL MYERS / MM&M CONSTRUCTION DATE PERFORMED: /'/9/O3 LEGAL DESCRIPTION: LOT 16, BLOCK 3, KNIK VIEW SUBD. TEST HOLE # REDDISH ORCANIC SILTY-SANDS POORLY GRADED SILTY-SANDS SP 2 SLOPE 2% SITE PLAN TH2 o O TH1 NO SCALE / SEE ASBUILT COMMENTS: WAS GROUNDWATER ENCOUNTERED? IF YES, WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: WELL GRADED DATE: SANDS W/GRAVELS SW NO S L O None P E /'/29/2003 < 2% GROSS NET DEPTH OF NET READING DATE TIME TIME WATER DROP Start /,/9/03 11:/,5 12.0" 1 12:15 30 ?.25" /'.?5" Recharge 12:15 12.0" 2 12:/'5 30 ?.25" /,.?5" Recharge 12:/,5 11.'/5" 3 13:15 30 '/.0" /'.?~" PERC RATE: 6.3 MIN./INCH PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN /+.5 FT. AND. 5.5 FT. NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST TEST PERFORMED BY: T.L. KIMBROUGH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST wAs PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON TH~S DATE: /'/29/2003 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 16, BLOCK 3, KNIK VIEW ESTATES SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250-gallon tank at the location shown on the site plan. Work also includes the construction of a new absorption trench 47' long by 3' wide by 8' effective depth also at the location shown on the Site Plan. The total depth of the trench will be 10' below existing ground and the distribution pipe will be placed at 2' below the surface. All components of the new absorption trench and septic tank must be constructed a minimum of 100' from any surface water and 10' from water services in the area. A minimum of 4' of cover is required over the septic tank and 3' over the absorption trench. In lieu of cover 2" of direct bury insulation and 2' of cover may be placed. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and MuniciPal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,250-gallon septic tank must be procured from a certified septic tank manufacturer if the existing tank is found to be defective. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. Lot 16, Block 3, Knik View Estates May 1, 2003 Page 2 ~of 3 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. o A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. ° Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. o Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. o A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. Lot 16, Block 3, Knik View Estates May 1, 2003 Page 3 of 3 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be tiffed with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backtilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes,'cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. Municipality of-Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 051.043.18 GENERAL INFORMATION Complete legal description . Location (site address or directions) 'z'~'u~d~D~ve Current Property owner(s) Mailing address Lending agency Oq OlCl q Expiration Date: .--k'-- ~/'// -' 0 ,.~ Lot 16, Block 3, Knik View Estates Subdivision MM&M C(~ntractin,q P.O. Box 670495 Chu.qiak, AK 99567 Day phone 688.1236 Day phone Mailing address Real Estate Agent · .. Mailing Address Un/ess otherwise requested, HAA wi//be held by DSD for pickup. 2. NUMBER OF BEDROOMS: Four {4) Day phone e TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class _A Well Public Water System TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] F'I. Individual Holding tank [] [] Community On-site D [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) ISsues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an ir{dependent professional civil engineer registered in the State of Alaska. Cedificates of Health Authority Approval are required for the transfer of title (except between spouses) for propedies served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners'. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be'reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. STATEMENT'OF INSPECTION BY ENGI'NEER" '. -.. ". As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site. water supply and/or wastewater disposal 'system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) Jn compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson En,qineerin.q- Address p.O. Box 240773 Anchora,qe, AK 99524 Engineer's Printed Name Michael E., Anderson, P.E. DSD SIGNATURE Approved for /-~ "' Disapproved. bedroOmS`. Conditional approval for - Phone 522.7773 Date 5/19/2004 '~- bedrooms, with the following stipulatiOns: Additional Comments Attach'ments: HAA Checklist · Septic System Advisory Well Flow Advisory . X Maintenance Agreements Supplemental Engineer's Report Other Original cedificate Date: , ,.~' ,~ L//, - ~) ~ (Rev. 12/00) Legal Dies, cription: A. WELL~ D,~TA Well type ~ Date c(~mpleted Date of test Static tw~ter level Well p, ro:duction ~. i~ .] WATER.SAMPLE RESULTS: ".Coliform ~__~olonies/100 ml. Date'o{' s.~mple: B. SEPTIC/HOLDING TANK DATA - 'MunicipalitY of AnchOrage Development Services Department Building SafetyDivision,. ~'~ ' ' On-Site Water & Wastewater Program ..... :~, ~: ": 4700 South BragawSt. i ~ 'P.O. Box 196650 Anchorage, AK 99519-6650 ' ': ' www:ci.anchorage.ak.us :: (907) 343-7904 '.. HEALTH AUTHORITY APPR£ Lot 16, BloCk 3, Knlk View Es{ates Subdivision .... ID: 051.043.18 (Y/N} ~bove grO.Und) g.p,m. i w!ies prop, ::Casing hei! in, Tank T, yp:e/Material Sel~ticlSieel ~.~ t .~ ;i:i~ .... ,~ ..~ Tankslze t,250 gal. ~ ;NumberofCompadments2 'Found~ti0n cleanout (Y/N) DepressiS~ 'over tank ~/N)"'N- :~ .High wa.~ '~ ,,,,l~r (Y/,,;) Date o~ p, ump,ng .- Pumper New Construction. C. 'ABSORPTION FIELD DA . .~ · , Date i~st~lled 812812003 :: ~oil rating (g.~.~./ftZor fl~/bdrm)~.8 GPDISF Sy . Width ~3 ;' ':;',L: ;' "'. Gr Lengt~ ~'47 fl Total de~th 11.5 fl. Eft.; absorption area'752.ft~ ' ~ .... I~Res'u~ts (P~ss/E~,) Date of adequacy test ' -" Fluid de~th in absorption fiel~ before test ,--.m. Water added . 'g~ Elapsed Time: min. :'- Finalfluid dePth, in.. ~:~..- ~Absorpti Any rejuvenation treatment (past 12 mo.)(Y~ & type) N , ;,~: i, .. ; . i ! i;:' N ii~e 'Deep Trench ~'l~w p,pe 8: )ress~on over field N_ ft. :i For bedrooms : " ,New depth in. g.p.d. ye,s, g~v,e date. .i1:[ A, B, or C pro~i~e PwsID # ..~ Sanitary seal (Y/N) '' cased to fl.'' FROM WELL LOG ; , i~ [ft. ~ :g.p.m. Nitraie !. col eCted by: :: :Daie in~,'t~ll~d 8i27/2003 '!:Other bacteria ,. : colomes/lO0 mi. D. LIF'r.. STATION - ,Date installed Size in gallons Manhole/Access (Y/N) · ".Pull5 on" level at. ~-in. "Pump off'" level at in. High water alarm level at Datum ' ' CyCles tested Meets alarm & circuit requirements? E.' i SEPARATION DISTANcEs SEPARATION DISTAN'CES'FROM WELL ON LOT TO: ' i -~i '. :. ~. ; . " ~, .... ' Septic tank/lift station On 10t NIA On adjacent lots NIA ~bsorption fie!d on lot NIA On adjacent lots NIA PubliC sewer main NIA' :, · Public sewer manholelcleanout N/A ~ewer~/septic service~,linel,, NIA Holding tank NIA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: ~uilding fgundation >5', ' Propertyline >5' Absorpiion field >5' Water main ' >10' ; Water service line >10' Surface water >100' lots, >200 · Wells on adjacent ', I, ' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: ' Prope,'~..., line ~,-./_.~i!: · , Building foundation >10' Water main >10' Water, Set;vice line, >10'. : Surface water >100' Driveway, parking/vehicle storage ;>5' Curtain'drain None Noted Wells on adjacent lots >200' F. COMMENTS "[:. properly i~ Sen/ed by P'ubli~'Water System. _': ~' ENGINEER'S CERTIFICATION . ' ' .,.~'~. ~_..';... ............ Ii: ..... ."' , .- I berlify that I have. dete/'mined through field inspections and ~ review of Mun,c/pal recoTds ~hat the above systems are in ~riformai~ce with MOA HAA guidelines in effect on this date. . [~,ng,neer's, Pr,nted Name ~ Michael E. Anderson, P.E. ~;~.o.:'No. ! i;~ D~tel;'o:t' Date of Payment .~"'-/'~ R~¢ ~"Z~' ~' 7 5" Receipt Number .!(Rev. ?JO0) .,I ~ ~ ,I - -- : .. -- _ : .... - .. .:::' ,:. 90?6881238 Oct. 13 2003 ll:OSAM PS ~L.. ~.. . . ~ .. ~.,. :L .....5.,.'~ . . ..~.~ 'L ?.;.'.. .: ....'. L-"' · ":'.' :.'" .... . '.,~;:.., '.....'. ~ :ANDERSON ENGINEERING 'P.O. B°X 240773 ANCHORAGE, AK 995~4 May 24, 2004 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 16, Block 3, Knik View EStates Subdivision Separation Distance Waiver Absorption Trench to Lot Line Dear On Site Services Engineer: The septic system on Lot 16, Block 3, Knik View Estates was inadvertently placed within 4' of the north property line. The lot lines were not clearly marked during construction and the end of the trench was mistakenly placed within 10' of the property line. We are therefore requesting a waiver be granted allowing the trench to be at 4' from the northern line. A majority of the new trench will be a minimum of 10' from the lot line. Placement of the new absorption trench at the existing location does not impact wells or adjacent septic systems. The subdivision is served by a community water system. We therefore recommend a waiver be issued allowing the new trench to be constructed at 4' from the east property line. Sincerely, Michael E. Anderson, P.E.