ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW03031~ 12.. ! PID Number:. 051-481-31
Name:
MM&M Contracting, Inc. WastewaterSystem: New
Address:
P.O. Box 670495 Chugiak, AK 99567 ABSORPTION FIELD
Phone: Number of Bedrooms:
688-1236 Four {4) Deep Trench
LEGAL DESCRIPTION Se,.ating: Tote, ~pth from orig~na, grade:
.8
Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe:
3 16 Knik View Estates 2
Township: Range: Section: Fill added above original grade: Gravel Length:
1-2
Well: Public Water System c~-~ve~ width: Number of lines: J Distance between lines:
3 r,. 1 rt.
rJ~$_~calion (Private, A, B. C): Total Depth: Cased Io: Total absorption area: Pipe Material:
A rt. rt. 752 v,' ASTM 3034 PVC
Driller: Date Drilled: Static Water Level: Installer:. ~ Date Installed:
v,. MM&M Contracting, Inc. 8/27-28103
c,u rt. Ft. TANK
SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. . [] Other:
Septic Absorption Lift Holding ~ublicJPdvateManufacturer; Capacity in Gallons:
Tank Field Station Tank Sewer Line Anchorage Tank .1,250
MatenaI:
~ Number of Compartments:
we,, ·200' ·200' N/A N/A ·25' Steel Two (2)
Su,aceWaler>100' >100' N/A N/A ~ LIFT STATION - NONE ON LOT
Lot IJne >5' 4' N/A N/A ~,e: ~,anutacturer:
Gal.
Voundation >5' · 10' N/A N/A ',,,mp on' level at: 'Pump Off' level at: I H,gh water alarm at:
in.in. in.
Curtain Drain None Noted Pump Uake& ~o~e, ~,e~,,nsp~,o.s pe,o..ed by:
Remarks:
BENCH MARK
See Lot Line Waiver. Location and DescnpDon:
Garage Slab
Assumed Elevabon:
100.0 Ft.
Engineer's Stamp
Inspections performed by:_T.L. Kimbrough Dates: 1't 8~27~03 ~ .-'" 49th ~~~%~'~
2nd 8/28/03 ~o' ~,C.*,L ~. ^,,~_~,SC. ~.' --'
Department of Health and Human Services approval · ~: . .-~.
· ..r,?,, No c£-438~ -*'~"~,
Reviewed and approved by: ~j~"~ ~' /~'~/..,~~ate:
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: SW030121
Page 2 of 3
PID No. 051o043-18
/ c4
~TH 1
,13
JA B
S1 28.1 169.1
S2 35.0 170.8
C4 42.5 174.2
40.9 ~72.5
C5 46.1 142.1
NA.S
PLA -BUILT
,,..~
SCALE I =40
LOT 28, BLOCK 3, KNIK VIEW ESTATES SUBDIVISION
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: SW030127
Page 3 of 3
PID No. 020-052-25
95,55
81.4
99,5
Dr'~zlnFleid Rock
35' (Tr,ench Length)
PROFILE AS-BUILT
Scale: 1' = 10'
, H[CHA£1_ ~ ANi~ER'~DN
No. CE-438t
MUNICIPALITY OF ANCHORA GE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 9951g-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: May 08, 2003
Expiration Date: May 07, 2004
Permit Number: SW030t2t
Legal Description:~.KNIK_VI EW,E ,STATES ' BLOCK 3 i LOT. 16'
Design Engineer: 0014 Anderson Engineering
Owner Name: MM & M CONTRACTING
Owner Address: PO BOX 670495 Total Bedrooms: 4
CHUGIAK, A 99567-
Parcel ID: 051-043-18
Site Address: NHN JUDD DRIVE
Lot Size: 24620 SQ. FT.
Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank
r-~ Holding Tank [-~ Privy
Private Well
[] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak, us
(907) 343-7904
ON-SITE SEWERNVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D.O51-043-18
Permit Number SWO~
Property owner(s) MM&M Contractinq
Mailing address (1) P.O. Box 670495 Chuqiak, AK 99567
Mailing address (2).
Day phone 688.1236
.Zip Code
Legal description (Lot, Block & Sub'd.) Lot 16, Block 3, Knik View Estates Subdivision
Legal description (Section, Township & Range)
Lot Size 24, ~' 2 0 Acres~]~ Number of Bedrooms Four (4)
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
[] Well Only [--~'
[] Water Storage []
[] Jacuzzi []
[] Water Softening Unit []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees:
Date of Payment:
Receipt Number:
(Rev. 12/00)
Waiver Fees:
Date of Payment:
Receipt Number:
ANDERSON ENGINEERING'
.. : ...-:i:P.O. Box 240773 : :. ~:':'..,.
. - - 'ANCHORAGE, !AK 99524
. 522'7773 : '' 522~:67.79 (FAx)
May1,2003
Municipality of Anchorage
DeVelopment Services Department
On-Site Water and Wastewater Program
4700 South Bragaw. Street
Anchorage, AK 99519-6650
Subject: Lot 16, Block 3, Knik View Estates Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 16, Block 3, Knik View Estates Subdivision intends to construct a
four-bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a new septic system to serve the proposed home. The attached Site
Plan and backup documentation identify the location and configuration of the new
septic system and the parameters used in the design. Also identified on the plans are
the location of the water service on the lot and the test hole locations. Existing drainage
patterns are shown and will not be altered by the development of the lot.
The test hole placed near the location of the proposed absorption trench indicated
poorly graded silty sands with varying amounts of gravel. Percolation tests in the
material resulted in rates of 6 minutes per inch. No groundwater was found during the
placement of the test holes and none was noted during the monitoring period. We are
therefore proposing to place a 47' long 3' wide by 8' effective depth absorption trench.
The total depth of the trench will be 10'. The distribution pipe will be placed at 2' below
the ground surface to provide sufficient drop from the septic tank to the absorption
trench. Surface drainage patterns will be maintained after construction is complete.
The ground surface on the lot slopes as shown on the attached Site Plan with a shallow
slope near the proposed absorption trench. The new absorption trench will be
constructed on a fairly fiat surface in conformance with Municipal requirements and
parallel to ground contours where possible. All components of the new septic system
will be constructed a minimum of 100' from the existing well on the lot.
If the system is constructed in accordance with our design the following statements
apply:
Lot 16, Block 3, Knik View Estates
May 1, 2003 '
Page Two
o
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
.3.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
12
'13
AREA MA
SCALE 1" = 100'
LOT 16, BLOCK 3
KNIK VIEW ESTATES
*Alt.
2% Site
TH 1
®
1,250 Gallor
Septic Tank
Long x
~ 10% Effective Depth
Absorption Trench
.13
Four
Bedroom
Home
+25%
SITE PLAN
SCALE 1" = 40'
LOT
16, BLOCK 3, KNIK VIEW ESTATES SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom House Deep Trench System
Perc. Rate: 6 Min./Inch 1,250 Gallon Septic Tank
Application Rate: .8 GPD/SF 8' Drainfield Rock
4 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 750 SF Absorption Area
750 SF/16 SF/LF = 46.9 LF Trench Length
THEREFORE: Construct a 47' Long x 3' Wide x 8' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 2' Below Odginal Ground Surface. Total Depth to be
10' Below Existing Ground. Maintain 10' Separation From Water Service on Lot. Provide 3' of
Cover Over Trench and 4' Over Septic Tank or Provide 2" Insulation and 2' of Cover.
6#
8~0"
Natural
Backfill
~ Geotextile
/ IFabric
4" Perforated
· ,, C>
-~_ PVC (Holes Down) -- Drainfield Rock
TYPICAL DEEP TRENCH SECTION
NOTE: Grade Are~ Over Trench to Drain Away.
Minimum 6. Separation From Bedrock.
Minimum 4 Separation From Groundwater.
Minimum 100: Separation From Wells in the Area.
Minimum 100 Sepa~tion From Sudace Water or Streams.
I
2--
3--
5--
6--
7
8
9
18
PROJECT #:
PERFORMED FOR:
JVIUNICIPALITY OF ANCHORAGE
DEPARTHENT OF HEALTH & HUHAN SERVICES
825 L STREET, ANCHORAGE, AK gg502-0605
SOILS LOG - PERCOLATION TEST
H0319
PAUL MYERS / MM&M CONSTRUCTION
DATE PERFORMED:
/,/9103
LEGAL DESCRIPTION:
LOT 16, BLOCK 3, KNIK VIEW SUBD.
TEST HOLE #
REDDISH ORGANIC
SILTY-SANDS
POORLY GRADED
SILTY-SANDS SP
1 SLOPE
< 2%
SITE PLAN
TH2
o
o
TH1
NO SCALE / SEE ASBUILT
COIiMENTS:
WAS GROUNDWATER
ENCOUNTERED?
IF YES, WHAT DEPTH?
DEPTH OF WATER
AFTER IVIONITORING:
WELL GRADED DATE:
SANDS W/GRAVELS SW
- ~ :."'
,0. ,,-,,,, %.?
NO S
L
O
P
None
E
/,/29/2003
<2%
GROSS NET DEPTH OF NET
READING DATE
TIHE TIHE WATER DROP
Sfarf /,/9/03 11:35 12.0"
1 12:05 30 ?.0" 5.0"
Recharge 12:05 12.0"
2 12:35 30 ?.0" 5.0"
Recharge 12:35 12.5"
3 13:05 30 ?.5" 5.0"
PERC RATE: 6 MIN./INCH PERC. HOLE DIAMETER: 6"
TEST RUN BETWEEN 5.5 FT. AND 6.5 FT.
NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST /,/29/2003
TEST PERFORHED BY: T.L. KIHBROUGH
I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND IVIUNICIPAL GUIDELINES ON THiS DATE: /*/29/2003
I
2
5
6--
7
8
9--
Ill
PROJECT #:
PERFORMED FOR:
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH ~ HUMAN SERVICES
825 L STREET, ANCHORAGE, AK gg502-0005
SOILS LOG - PERCOLATION TEST
M0319
PAUL MYERS / MM&M CONSTRUCTION
DATE PERFORMED: /'/9/O3
LEGAL DESCRIPTION:
LOT 16, BLOCK 3, KNIK VIEW SUBD.
TEST HOLE #
REDDISH ORCANIC
SILTY-SANDS
POORLY GRADED
SILTY-SANDS SP
2 SLOPE
2%
SITE PLAN
TH2
o
O
TH1
NO SCALE / SEE ASBUILT
COMMENTS:
WAS GROUNDWATER
ENCOUNTERED?
IF YES, WHAT DEPTH?
DEPTH OF WATER
AFTER MONITORING:
WELL GRADED DATE:
SANDS W/GRAVELS SW
NO S
L
O
None P
E
/'/29/2003
< 2%
GROSS NET DEPTH OF NET
READING DATE
TIME TIME WATER DROP
Start /,/9/03 11:/,5 12.0"
1 12:15 30 ?.25" /'.?5"
Recharge 12:15 12.0"
2 12:/'5 30 ?.25" /,.?5"
Recharge 12:/,5 11.'/5"
3 13:15 30 '/.0" /'.?~"
PERC RATE: 6.3 MIN./INCH PERC. HOLE DIAMETER: 6"
TEST RUN BETWEEN /+.5 FT. AND. 5.5 FT.
NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST
TEST PERFORMED BY: T.L. KIMBROUGH
I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST wAs PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES ON TH~S DATE: /'/29/2003
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 16, BLOCK 3, KNIK VIEW ESTATES SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,250-gallon tank at the location shown on the site plan. Work
also includes the construction of a new absorption trench 47' long by 3'
wide by 8' effective depth also at the location shown on the Site Plan.
The total depth of the trench will be 10' below existing ground and the
distribution pipe will be placed at 2' below the surface. All components
of the new absorption trench and septic tank must be constructed a
minimum of 100' from any surface water and 10' from water services in
the area. A minimum of 4' of cover is required over the septic tank and
3' over the absorption trench. In lieu of cover 2" of direct bury
insulation and 2' of cover may be placed.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and MuniciPal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,250-gallon septic tank must be procured from a certified
septic tank manufacturer if the existing tank is found to be defective.
A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
Lot 16, Block 3, Knik View Estates
May 1, 2003
Page 2 ~of 3
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
o
A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
°
Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
o
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
o
A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
Lot 16, Block 3, Knik View Estates
May 1, 2003
Page 3 of 3
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be tiffed with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backtilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes,'cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
Municipality of-Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051.043.18
GENERAL INFORMATION
Complete legal description .
Location (site address or directions) 'z'~'u~d~D~ve
Current Property owner(s)
Mailing address
Lending agency
Oq OlCl q
Expiration Date: .--k'-- ~/'// -' 0 ,.~
Lot 16, Block 3, Knik View Estates Subdivision
MM&M C(~ntractin,q
P.O. Box 670495 Chu.qiak, AK 99567
Day phone 688.1236
Day phone
Mailing address
Real Estate Agent
· .. Mailing Address
Un/ess otherwise requested, HAA wi//be held by DSD for pickup.
2. NUMBER OF BEDROOMS: Four {4)
Day phone
e
TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class _A Well
Public Water System
TYPE OF WASTEWATER DISPOSAL:
[] Individual On-site []
F'I. Individual Holding tank []
[] Community On-site D
[] Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) ISsues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an ir{dependent professional civil
engineer registered in the State of Alaska. Cedificates of Health Authority Approval are required for the transfer of
title (except between spouses) for propedies served by a single family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners'. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be'reissued with
new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with
valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water
system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's
work.
STATEMENT'OF INSPECTION BY ENGI'NEER" '. -.. ".
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-
site. water supply and/or wastewater disposal 'system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) Jn compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm Anderson En,qineerin.q-
Address p.O. Box 240773 Anchora,qe, AK 99524
Engineer's Printed Name Michael E., Anderson, P.E.
DSD SIGNATURE
Approved for /-~
"' Disapproved.
bedroOmS`.
Conditional approval for -
Phone 522.7773
Date 5/19/2004 '~-
bedrooms, with the following stipulatiOns:
Additional Comments
Attach'ments:
HAA Checklist
· Septic System Advisory
Well Flow Advisory .
X
Maintenance Agreements
Supplemental Engineer's Report
Other
Original cedificate Date: , ,.~' ,~ L//, - ~) ~
(Rev. 12/00)
Legal Dies, cription:
A. WELL~ D,~TA
Well type ~
Date c(~mpleted
Date of test
Static tw~ter level
Well p, ro:duction
~. i~ .]
WATER.SAMPLE RESULTS:
".Coliform ~__~olonies/100 ml.
Date'o{' s.~mple:
B. SEPTIC/HOLDING TANK DATA -
'MunicipalitY of AnchOrage
Development Services Department
Building SafetyDivision,. ~'~ '
' On-Site Water & Wastewater Program
..... :~, ~: ": 4700 South BragawSt. i ~
'P.O. Box 196650 Anchorage, AK 99519-6650
' ': ' www:ci.anchorage.ak.us ::
(907) 343-7904 '..
HEALTH AUTHORITY APPR£
Lot 16, BloCk 3, Knlk View Es{ates Subdivision ....
ID: 051.043.18
(Y/N}
~bove grO.Und)
g.p,m.
i w!ies prop,
::Casing hei!
in,
Tank T, yp:e/Material Sel~ticlSieel
~.~ t .~ ;i:i~ .... ,~ ..~
Tankslze t,250 gal. ~ ;NumberofCompadments2
'Found~ti0n cleanout (Y/N) DepressiS~ 'over tank ~/N)"'N- :~ .High wa.~ '~ ,,,,l~r (Y/,,;)
Date o~ p, ump,ng .- Pumper New Construction.
C. 'ABSORPTION FIELD DA . .~ · ,
Date i~st~lled 812812003 :: ~oil rating (g.~.~./ftZor fl~/bdrm)~.8 GPDISF Sy
. Width ~3 ;' ':;',L: ;' "'. Gr
Lengt~ ~'47 fl
Total de~th 11.5 fl. Eft.; absorption area'752.ft~
' ~ .... I~Res'u~ts (P~ss/E~,)
Date of adequacy test ' -"
Fluid de~th in absorption fiel~ before test ,--.m. Water added . 'g~
Elapsed Time: min. :'- Finalfluid dePth, in.. ~:~..- ~Absorpti
Any rejuvenation treatment (past 12 mo.)(Y~ & type) N
, ;,~: i, .. ; .
i ! i;:'
N
ii~e 'Deep Trench
~'l~w p,pe 8:
)ress~on over field N_
ft.
:i For bedrooms
:
" ,New depth in.
g.p.d.
ye,s, g~v,e date.
.i1:[ A, B, or C pro~i~e PwsID #
..~ Sanitary seal (Y/N)
'' cased to fl.''
FROM WELL LOG ; ,
i~ [ft.
~ :g.p.m.
Nitraie !.
col eCted by:
:: :Daie in~,'t~ll~d 8i27/2003
'!:Other bacteria ,. : colomes/lO0 mi.
D. LIF'r.. STATION -
,Date installed Size in gallons Manhole/Access (Y/N)
· ".Pull5 on" level at. ~-in. "Pump off'" level at in. High water alarm level at
Datum ' ' CyCles tested Meets alarm & circuit requirements?
E.' i SEPARATION DISTANcEs
SEPARATION DISTAN'CES'FROM WELL ON LOT TO: ' i -~i '. :. ~. ; . " ~, .... '
Septic tank/lift station On 10t NIA On adjacent lots NIA
~bsorption fie!d on lot NIA On adjacent lots NIA
PubliC sewer main NIA' :, · Public sewer manholelcleanout N/A
~ewer~/septic service~,linel,, NIA Holding tank NIA
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
~uilding fgundation >5', ' Propertyline >5' Absorpiion field >5'
Water main ' >10' ; Water service line >10' Surface water >100'
lots, >200
· Wells on adjacent ', I, '
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
'
Prope,'~..., line ~,-./_.~i!:
· , Building foundation >10' Water main >10'
Water, Set;vice line, >10'. : Surface water >100' Driveway, parking/vehicle storage ;>5'
Curtain'drain None Noted Wells on adjacent lots >200'
F. COMMENTS
"[:. properly i~ Sen/ed by P'ubli~'Water System.
_':
~' ENGINEER'S CERTIFICATION . ' ' .,.~'~. ~_..';... ............
Ii: ..... ."' , .-
I berlify that I have. dete/'mined through field inspections and ~
review of Mun,c/pal recoTds ~hat the above systems are in
~riformai~ce with MOA HAA guidelines in effect on this date. .
[~,ng,neer's, Pr,nted Name ~ Michael E. Anderson, P.E. ~;~.o.:'No.
! i;~
D~tel;'o:t' Date of Payment .~"'-/'~
R~¢ ~"Z~' ~' 7 5" Receipt Number
.!(Rev. ?JO0) .,I ~ ~ ,I - -- :
.. -- _ : .... - .. .:::' ,:.
90?6881238 Oct. 13 2003 ll:OSAM PS
~L.. ~.. . . ~ .. ~.,. :L .....5.,.'~ . .
..~.~ 'L ?.;.'.. .: ....'. L-"' · ":'.' :.'"
.... . '.,~;:.., '.....'. ~
:ANDERSON ENGINEERING
'P.O. B°X 240773
ANCHORAGE, AK 995~4
May 24, 2004
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject:
Lot 16, Block 3, Knik View EStates Subdivision
Separation Distance Waiver
Absorption Trench to Lot Line
Dear On Site Services Engineer:
The septic system on Lot 16, Block 3, Knik View Estates was inadvertently placed
within 4' of the north property line. The lot lines were not clearly marked during
construction and the end of the trench was mistakenly placed within 10' of the property
line. We are therefore requesting a waiver be granted allowing the trench to be at 4'
from the northern line. A majority of the new trench will be a minimum of 10' from the
lot line.
Placement of the new absorption trench at the existing location does not impact wells or
adjacent septic systems. The subdivision is served by a community water system. We
therefore recommend a waiver be issued allowing the new trench to be constructed at
4' from the east property line.
Sincerely,
Michael E. Anderson, P.E.