HomeMy WebLinkAboutBARNETT ESTATES LT 2 Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181361 PID Number: 05109270 Dwelling: ❑■ Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑■ Upgrade Name Barnett ABSORPTION FIELD Site Address [ Duch 1WiTench ❑ Bed ❑ Mound Scenic Drive ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 441-2664 3 1.2 GPD/SF 7.5 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 3.5 Ft. 4 Ft. Barnett Estates 2 Fill added above original grade .Gravel length Township Range Section 0.5 Ft. 39 Ft. Gravel width Beds: Number of Lines Distance between lines SEPARATION DISTANCES 5 Ft. - - Ft. ToTotal absorption area Number of trenches Dist. between trenches Septic Absorption Lift Station Holding ' Sewer From Tank Field Tank Line 390 Ft2 1 _ Ft. Well 1 Q0'+ 100'+ na na 25'+ TANK 1=1 Septic ❑ S.T.E.P. ❑ Holding El Other Manufacturer Capacity Greer 1000 Gal. Surface Water 1 QQ'+ 100'+ na na Material Number of compartments Lot Line 10'+ 10'+ na na NA Steel 2 LIFT STATION Foundation 10'+ 1 0'+ na na Manufacturer Capacity Remarks Gal Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 drainfieldTank to D3034 Installer Alex's Enterprises Drainfield D3034 CO/MT D3034 Inspector BENCH MARK (Assumed elevation) 100 ft Inspection 15' 11/14/18 11/15/18 Location and description dates: 2""4th s2nd Story Deck3P/ 11/19/1�i ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date Septic System —---_-_—� "//230 Approved (`' Date S-7'17 Note: this approval does not include well permit requirements. (Rev 05/02/18) • R10 L1 _U o > +' pl Well 1 a 0) T /^ N v/ U N _U a vj L38B d Well>200' i o, N 3 New 100Q Gallon ' Flat Slope Septic an w/DC❑ s I o L38A TH (chrls Wood) — Well>200' Mt/CD Rio U 3119 3 Bdrrns Driveway -�-' o Flat Slope 11 0 CO Well IR- CO2 A Flat Slope Trench Flat Slope L1 L56B Flat Slope --------/ — Flat Slope -150 / .AS-BUILT MEASUREMENTS A B ST1 27 14 ST2 31 20 DCO 37 30 MT/CO 36 52 / CO2 43 34 �o~��,` 1" = 60'NORTHRIM •PF..°F '.. , BARNETT ESTATES ENGINEERING ,#�,'�.•- cif SteveEng.com * 49m, * LOT 2 RECORD PO Box 770724 ;�' '� tr LAYOUT Eagle River. Alaska 99577 -ate WASTEWATER RECORD °'.694.'°z8I1/4WELL SITING Dote: 5/6/19 12 of 3 Foundation Cleanout Elevation @ 91' (final ground) / Tank Cleanouts Elevation @ 87' Fin ^amide Opposing Cleanouts Between Septic Tank & Trenches 4 Foot Cover or Equal Elevation @ 86,5' ......,./1000 Gallon levation @ 87' Septic Tank11\ Elevation @ 86,4' MOA-Approved Monitor Tube Solid Pipe _fleanout Original/Final Ground @ 89.5 ,5, Filter Fabric ��, . '. . • Elevations Both EndsElevation @ 86' :=Ilz IP"•: 0,7 I 0,70, :: :.:::::::_•_ _: ! 4' ! ! 4 ! != 7,5' Drain Rock ' 1,;11.70;1;,4:11s,- .P.: '=0 !=' != : : •. : :; Elevation @ 82' P` iz!`i ! !'!` is i :: : :: TH Elevation @ 76' (No Water10/7/18) ! !'= t/L L--Jope10. izxoqut#Lum <qe /yn/liew/u(oyepoo6•Ileum:sduy .'ICE WATER WELL DRILLING A subsidiary of ACE Ventures,Inc. P.O. Box 520090 • 1167 N.Knapp Dr Big Lake,Ak.99652 (907)357-7987 fax (907)376-7987 (907)354-1398 cell Well Owner The Thomas Company Use of Well: Domestic Location: Lei 2 Barnett—Birchwood Alaska aka 20712 Scenic Drive Date of Completion: 11/14/2015 Job n 15-43 Iilling Method Air Rotary Size of Casing: 6" Depth of hole 225 feel Cased to: 116' feel Static Water Level: 30 feet below top()leasing Finish of Well( )Open End ( X )Grout/Seal (X)Screen/Liner 1 X )I'ri ligated Describe screen,seal,or perforation: PVC Liner set from 225 to 116 feet. Perforated front 6o to(.3 feet below TOC. Bentonite Surface Grout Seal. Well Pumping Test at 3 Gallons per ( )bout (X )minute Suggested Pump setting depth 220 feet from top of casing. Method of disinfection: Chlorine tablets Depth in feet from casing Details of Formations/size/color/etc top 0 to 3 feet Stick up __ 3 to 34 feet Silty gravel and cobbles 34 to 60 feet Clayey silty gravel and cobbles 60 to 63 feet Sandy coarse gravel-water 63 to 116 feet Clayey silty gravel 116 to 176 feet Shale bedrock 176 to 225 feet Sandstone bedrock-hard Driller Signatu =���� A. Date: 1034; --I 6d4(66£)a6ewl 6102/£Z/b L/L L=Joparoidzxogwywnn=geluO/n/liew/woyal6006•iew//aduy Ace Water Wells P 0 Box 520090 Big Lake,Ak.99652 (907)376-7987 aceh2o@mtaonline.net Pump Installation Log Well Owner: The Thomas Company Job#P18-43 Installation Date: 12/18/2018 Legal Description::Lot 2 Barnett aka 20712 Scenic Drive-Birchwood Pump Intake Depth: 215 feet below top of casing(TOC). Pump Manufacturer: Goulds Well Depth: 225' Model: HS 2 wire Size: 6 Horse 5 GPM SN: F1663152 Pitless adapter buried depth:12'below TOC Disinfection method: Chlorine tablets Additional comments: None A74-14-- t jj Q �fj�,{,4 l° Date I� 20r I u Installer signature: '" 6d1(0017)a6ewi 6LOZ/9/S MUNICIPALITY OF ANCHORAGE Rent On-Site Water&Wastewater Program �o S^� idi Agee PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 „r http:Nwww.muni.org/onsite + r. Dc n Intl)t CONCH ORRGO On-Site Water & Wastewater System Permit Permit Number: OSP181361 Effective Date: 10/16/2018 Work Type: WellSeptic Initial Expiration Date: 10/16/2019 Tax Code Number: 05109270000 Site Legal Address: BARNETT ESTATES LT 2 G:1357 Site Mailing Address: Owner: BARNETT SEAN D Lot Size in Sq Ft: 49470 Design Engineer: NORTH RIM ENGINEERING Total Bedrooms: 3 This permit is for the construction of: 0 Disposal Field Q Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing • Special Provisions: The Engineer is required to do an additional percolation test prior to construction of the septic field. Please submit stamped and signed results with the As-built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. Received By: Date: ld7‘ l d' Issued By: I Date: /OA MUNICIPALITY OF ANCHORAGE ,,,,....._._t___.,,, Development Services DepartmentPhone: 907-343-7904 On-Site Water & Wastewater Section Fax. ': . ,4 -7997 '1) ROWt X56 'O , / ‘alk ON-SITE SEPTIC/WELL PERMIT APPLICATION OCT 0 91018 n 3 Parcel I.D. 0510q2 7 U 2 w ii Property owner(s) 7710014--,is CO. &V (104.244 Day phone_3ss— ".? •' " %# 7710014--,isMMailing address Po ,5O 010 e /0.4L44 Z, ,' 1 ciws- Site address SCi—iJtG O2/V Legal description (Sub'd., Block & Lot) ,8 4-, /\/,:-..:7--r T cf'7 �.=.9 L 2 Legal description (Township, Range & Section) Lot Size LA 4170 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (IE all that apply) Absorption Field Initial Single Family (SF) Septic Tank eer Upgrade ❑ (w/wo ADU) Holding Tank ❑ Renewal Duplex (D) ❑ ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well F.. Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Pg (Signature o property owner,Authorized agent) Permit/Rush Fees: 413 .vo Waiver Fees: Date of Payment: 0 a g Date of Payment: Receipt Number: i` S .4 O Receipt Number: Permit No. OSR$t3 10I Waiver No. G:\Development Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc NIr\k2RTF— I M NGINEERING SteveEng.com Steve Eng,PE,PH 907-694-7028 SteveEngPE@gmail.com Date: 10/9/18 Number of Pages: To: MOA On-Site Services Subject: Barnett Estates Lot 2 New Septic System & Water Well A new residence is planned for the subject empty lot. A soil test reveals sand w/gravel soil and no groundwater.The design calls for a new trench and a new septic tank.Most of the subdivision is on water wells&septic systems.The terrain slopes slightly to the north overall and is flat slope at the trench site. The system size is a single family at 3 bedrooms. A well location is depicted. Please review the wastewater system design for the existing 3 bedroom home. I have included design plans&specs, design guidelines, &soil test. If there is need for additional information or clarification please give me a call. Thanks-Steve •••.asp. T� ZIIV ; • ENGINEERING 1 +1 7 SteveEng.com B tt Esta, of a� i. • W t^^ ..t?.rtes W.-tag tv 1 SPECIFICATIONS & DESIGN GUIDELINES �4 F , 411- 74ci= �0P/:JFESS\°� �' Wastewater System Sizing: This is a new 3-bedroom, single family home. Th°s-ncxv..wa,.�' developed subdivision. These lots are large with private water wells serving most of the area.No adverse impacts are expected from the development.No conflicts to the other lots will take place by this septic system construction and water well. A soil test reveals silty sand w/gravel. An application rate of 1.2 GPD/FT2. Trench Length= 375 FT2/5'x 0.5 reduction factor=38' trench,4' effective. A new 1000 gallon septic tank will be installed. Proposed well may be placed in the fgeneral area on the drawing. Specification Requirements: All components and work must comply with the Municipality of Anchorage Specifications (AMC) & State of Alaska Drinking Water Regulations and Wastewater Regulations. • Two compartment,New 1000 gallon septic tank. Install Double Cleanouts. • Install foundation cleanout. • 10' minimum between the tank trench,tank to house. 10' to property lines, • 3' of cover or insulation is required for trench; 2" Minimum thickness for insulation can substitute for l' cover. • Tank& solid pipe must be set on well compacted, stable soil. • 4 inch diameter cleanouts with airtight caps are required 1' to 4' from foundation wall,prior to any 90 degree bend in 4 inch line, in each tank compartment, and two adjacent opposing cleanouts between the tank and the absorption field, not more than 10' from the tank positioned to provide cleanout access towards the tank and towards the absorption field. • All cleanouts must extend to at least ground level. • In solid pipe runs, ASTM D-3034 may be used in lieu of cast iron. • Trench to be placed level,minimum of 4' to groundwater, 6' to bedrock from drain-rock. • Drain rock to be V2 inch to 2 inch screened. Drain rock to be distributed uniformly throughout the trench. • Perforated pipe to be installed level with perforations down. • Silt barrier(filter fabric)to be installed above the drain rock. • Smeared trench sides must be raked or scarified before drain rock placement. • The finish grade must be mounded to promote drainage away from trench. • Insulation must be placed over any pipe installed under driveways or parking areas. • Approved pipe materials include cast iron, PVC ASTM D3034, PVC ASTM F789, ABS ASTM D2661, • Sewer Service Line is minimum 2%slope. • Septic Tank to be pumped every two years or when required. • Insulation board to be extruded direct burial polystyrene(Dow Styrofoam HI/equal) R10 L1 _U o > +' Well a u a) In u a 11/vj L38B — Well>200' oi, m v w R10 0-I D New 100Q Gallon Flat slope Septic Tank w/DCO's N L38A TH Proposed We — Well>200' Mt/COI ou f.;:)-u 38 3 Bdr s a Flat Slope Driveway (n) 5 CO Flat Slope Trench Flat Slope —• L1 L56B Flat Slope Flat Slope \150 DESIGN NOTES: 1. Trench Depth 0 7.5'. 2. Sewer Service Line minimum 2% slope. 3. Measure Separation Distances Prior To Construction. 4. Lots Served by Private Water Wells. 5. No Conflicts Within 200'. Mark 100' Well Radius. / is NORTHRIM _••"\ �.�.... IBARNETT ESTATES 1 60' ENGINEERING irc,,``:•,....9m *► • DESIGN SteveEng.com LOT 2 PO Box 7707241 LAYOUT Eagle River, Alaska 99577 V.= ,67:27w3 s WASTEWATER DESIGN 907.6 94.7028 WELL SITING 10/15/18 2 of 3 Foundation Cleanout . / Tank Cleanouts - Fin ^amide Opposing Cleanouts Between Septic Tank & Trenches 4 Foot Cover or Equal 1000 Gallon 'Anchorage Tank' Mounded Cover To Match Terrain Or Equal Monitor Tube Solid Pipe _/Cleanout DESIGN NOTES: 1. Depth of New Trench is 7.5'. 2. Septic Tank & Solid Pipe to be Placed on Compacted, 5 Stable Soil, Free from Boulders. Filter Fabric --___, ' . 3. Sewer Service Line is Minimum 2% Slope & 3' Cover. _I 'i'`, _ : 4, Water-Tight Couplings, •. : !:!::Mez 5. See Specification Sheet, !-• !'! !=.' •- 6. All Work To Conform to Municipality of Anchorage (AMC) '. .P`?..f?: f"f" .-..:_ Requirements & Specifications. 4 !; . ..• •: 7. Maintain 3' Cover Over Trench Dr Insulate, '' '`'`''''='` Drain Rock !=: !=P= '- ! '-= r�I P10.:%l.;��� iSc ! !:e=!% is i i i i f..e. 5' -------------------- N OR THRI M '•i-°'ilg ENGINEER/NG *'`49m ‘% TRENCH END VIEW BARNETT ESTATES SteveEng. com� $ SEPTIC TANK PROFILE . .:• LOT 2 Po Box 770724 Nr. c}�°s^s° .../'. SEPTIC SYSTEM Engle River Aiosko 99577t Date: Drawn SE Scute. 1' = 5 SHEET:3 Of 3 907.694.7028 (!` NEW 10/8/18 l SE S❑ILS LOG - PERC❑LATI❑N TEST NETER MDate Performed: 5/11/06 ENGINENEERRING Updated Monitor/Perk Performed: 10/8/18 Performed For: Barnett Legal Description: Barnett Estates Lot 2 DEPTH (FEET) T.H. Location: See Attached Test 1 - Organic ;{`. Boring Location Map 2 - vy; x• SP Sand 3 - :- . aA" • r; -4;a:�=' W/ Groundwater? No Depth ' w 6 - ,„; ; ?Y;- Gravel Water Depth 7 - .j' : a4• === After Monitoring.None Date: 10/8/18 >.:-.• 1';',';17.:4:*:-,} cont J # Date Gross Tine Net Tine Depth Net Drop 9 - = ;tiA (,JOoIS 1 10/8 6" 10 - :. L3CZ• :c 2 10/8 10 10 rein. 2' 4 11 - --.,-.c2,,,‹ 3 10/8 10 -- 6' -- 12 - ;:,0'.37Wr 4 10/8 20 10 min, 2' 4" 13 - ;: i5 10/8 20 -- 6' -- 14 - 6 10/8 30 10 min, 2' 4' 15 - 7 10/8 30 -- 6' -- 16 - 8 10/8 40 10 min. 2' 4' 17 - 9 10/8 40 -- 6' -- 18 - 10 10/8 50 10 min. 2' 4" 19 - 11 10/8 50 -- 6" -- 20 - 12 10/8 60 10 Min. 2" 4" 21 - Percolation Rate 2.5 min/in Perc Hole Diameter 6" Test Run Between 3' & 4' Comments: Measured To The Neares 1/16", Performed By NorthRim Eng. I CERTIFY THAT THIS TEST WAS Performed in Accordance/ ith All State/Municipal Guidelines in Effect ON THIS DATE. DATE: /6/(6(T NOR T H R I M ,--t*CF�iN AS...•...'.,• BARNETT ESTATES TH ENGINEERING SteveEng. com * '49m LOT 2 PO Box 770724 sta.log Eagle River, Alaska 99577 �-' ' T E S T H❑L E LOG 907.694.7028 6 ky14' • fie: — ; b/`V GE❑TECHNICAL 10/15/18 i .................,,,,,,.., A ....„ Az' 14 EAGLE RIVER ENGINEERING �P.. . • •/ ;• •s��., 10421 VFW RD, SUITE 201 �' • ` /� EAGLE RIVER, AK. 99577 A` * , (907) 694-5195 FAX: (907) 694-3297 0 // 0 to SOILS LOG PERCOLATION TEST � -- 0 - .CHRISTOPHER R. WOOD• c CE-10387 ,j+'PFS •• 4`�'� + Arir fit crESSIOI'At e" PERFORMED FOR: SEAN BARNETT DATE PERFORMED 5/11/2006 ti\\lovr.ii," LEGAL DESCRIPTION: T15N, R1W, SEC.8, LOT 37 TOWNSHIP RANGE SECTION T15N,R1YI,SEC.8 TEST HOLE # 3 SLOPE SITE PLAN(NOT TO SCALE) DEPTH ... =MOM UM... ,,.»• (FtET) , ' b ROA![�A 0 -""\-,-,../" -- 1 SANDY TOPSOIL —......w P, i ►. y • uv 12 3— ° C 4 BROWN LOOSE SAND / ., ' I I: S_ MIXED WITH COARSE GRAVEL COBBLES TO 10• 136 - 7—" Io.. . 8— .0 0 I ....ors X•••7X•••7'. 9---° SLOPE 0 .o o WAS GROUND WATER o o ... 11 — ENCOUNTERED? YES b •° 3% o g WATER MONITOR DATA 12 ;-o DATE 'WATER LEVEL 13— o 7. °. 05/11/2006,12' 14— 05/31/200611. 5' 06/19/2006 11.8' 15— PERC TEST RESULTS 16— READING DATE GROSS TIME NET TIME TDEPTH TO WATER NET DROP 17 - 1 1 18— 1e PECOLATION RATE WAS FASTER THAN 1 MINUTE PER INCH 20— 21 ' 22 PERCOLATION RATE.>1 (MIN/INCH) PERC HOLE DIAMETER■8• TEST RUN BEIWEEN 3 FT AND 4 FT COMMENTS. SOILS LO GED BY: CHRISTOPHER WOOD PERCOLATION TEST BY: CHRISTOPHER WOOD I _ / / /1/ ._CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE:1,./l110.G June 10, 2002 Municipality of Anchorage George P. llqterch, Mayor Building SmCc~, Division P.O. Box 196650 · 4700 S: Bragaw Strcct Anchoragc, Alaska 99519-6650 · (907) 8-~8-8801 http://www, ci.m~chomgc.alcus Terry Whiteman 8011 Clear Haven Cir. Anchorage AK 99507-3272 Subject: On-Site Water and/or Wastewater Permit. Permit Number: SW010263 L~'al'DeSefipti0nyT15NR1W~S~-~tiOii'8 L'6t'37.;i Dear Terry Whiteman: An On-Site WaterAVastewater Permit, number SW010263, issued by this office for a single-family system, will expire on July 25, 2002. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as-built inspection report must be sent to this office for review, approval and documentation. This as-built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As-built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $100.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $400.00 for a wastewater permit and $150.00 for a well permit. If you have any questions, please call this office at 343-7904. Mhnager On-Site Water and Wastewater Program Eno: Copy of permit MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jul 25, 2001 Expiration Date: Jul 25, 2002 Permit Number; SW010263 Parcel ID: 051-092-05 ~Legal Desc.ripti0n~i ~Ti5N R1W SEC 8 LT:37 Design Engineer: 0003 S & S Engineering Site Address: Owner Name: Terry Whiteman Lot Size: 108900 SQ. FT. Owner Address: 2~ Total Bedrooms: 4 Permit Bedrooms: 4 Anchorage, AK This permit is for the construction of: ['~ Disposal Field r~ Septic Tank Holding Tank [] Privy [~] Private Well [--] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 )and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~/ ~ Date: Issued By: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O, Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Permit Number SW Properly owner(s) Mailing address (1) Mailing address (2) Legal description (Lot, Block & Sub'd.) Legal description (Section, Township & Range) Lot Size ~,,. ~ ~ . THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Number of Bedrooms Well Only r--I. Water Storage [] F'-] Jacuzzi [] r'-] Water softening Unit I-1 I certify that the above information is correct. I further certify that this application is being made for a Single Family DWelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: t./,/,/O, o o Waiver Fees: Date of Payment: (~/~ g'/O ! Date of Payment: Receipt Number: O o t, 5' 3. ¥ Receipt Number: (Rev. 12/00) 17034 Eagle River Loop Road, No. 204 Eagle River, Alaska 99577 ROBERT C. COWAN, P.E. HEALTH ALffHORrlY APPROVALS SEWER&WATER I~ EXTENSIONS SEWER&WATER ff~SPECTION ENGINEERING STUOIES ANDREPORTS WEll INSPECTION & FLOW TEST SaTE PLANS ROAD DESIGN 801LTEST PERCOLATION TEST STRUCTURAL & MECHANIOAL INSPECTION~ ONSITE WA~TEWATER DISPOSAL SYSTEM DESIGN CMLENGINEERS (907) 694-2979 FAX (907) 694-1211 June 20, 2001 MUNICIPALITY OF ANCHORAGE Development Services Department P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 37, Section 8, TI5N, R1W It is requested that you issue a permit to install a well & a septic system to serve the proposed four bedroom dwelling on the referenced proper0~'. A test hole was excavated and a percolation test was performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation on 6/7/01 water was found at 6.5 feet. After seven days of ground water monitoring water was still found at 6.5 feet. We do not anticipate any adverse effects on neig!)~fi~g wells, septic systems, reserve areas or drainage patterns by the installation 6~:,i:~'e"proposed septic system. The construction of this system will not lJrevent any fut~i~'~6Velopment on any of the adjacent properties. If you require additional information, please contact us. Sincerely, RCC/jhm Enclosure 17034 NORTH EAGLE RIVER LOOP · SUITE 204 * EAGLE RIVER. ALASKA 99577 PERFORMED FOR.' Municipaliiy ol Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST SLOPEj' SITE PLAN WAS GROUND WATER ENCOUNTERED? DEPTH;' ~' p E ! I~10nil0rlng? . - Dale: Reading Date Gross Net Depth to Net Time Time Water Drop 0 0~-'~' 0 0 ~ -'- IO I0 IOYz. PERCOLATION RATE ~ (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN "~ FT AND ~ FT 1 2 3 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2O COMMENTS ! A ACCORDANCE wBa~J~LR~--,~7~l~lfak,~l~AL GUIDELINES IN ERFECT ON THIS DATE. 72-008 (Rev. ,$/85) CERTIFY THAT THIS TEST WAS PERFORMED IN aneemnq R'OBERT C. COWAN, P.E. CML ENGINEERS (907) 694-2979 FAX (907) 694-1211 SEWER & WATER MAIN EX~'EN~tON~ SEWER&WATER INSPECTION ENGINEERING STUOtES AND REPORTS ~ELL INSPECTION FLOW T EST SITE PLANS ROAD DESIGN SOIL TEST PEI~OLATION TEST STRUCTURAL & MECHANICAL INSPECTIONS ON SIT E WA~TEWATER DISPOGALSYSTEM DESIGN ON-SiY WASTEWATER DISPOSAL SYSTEM cONsTRucTION'P TIcEs and MATERIAL SPECIFICATIONS REFERENCE: Lot 37, Section $, T15N, R1W June 20, 2001 GENERAL: The scope of this project includes the installation of a 1300 gallon HDPE septic tank and a new trench to serve the proposed four bedroom residence located on the referenced property. Construction shall be in accordance with the approved site' plan and design drawings, Municipal permit with any special provisions or conditions, and all apphcable' State and Municipal Wastew, a. t.er.., ~.. D~sposal.. Regulations., The contractor shall be responsible for obtaining any necesSary underground utility locates. ' Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tanlc 17034 NORTH EAGLE RIVER LOOP · SUITE 204 ° EAGLE RIVER. ALASKA 99577 Page 2 ,. Lot 37, Section 8, Tt 5H, RIW ':: 'Iii June 20, 2001 .... .. 3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 4. Septic tanks installed with less than 4 ft. ofcover shall be insulated. A foundation cleanout shall be installed one to foul.., ~?t from the building foundation. In the line between the tank and the leachfield there shrill be two adjacent cleanouts (unless an effluent pumping system exists within th~ septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. .'.:" Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement. ..,¥:."i. :' Once the gravel is installed, the distribution pi~'?is'.ito be installed level with the perforations faced downward. Gravel is then to b~"'~ia~ed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page 3 Lot 37, Section 8, TtSH, RtW June 20, 2001 MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Municipal approved septic tank manufacturer. ":" The folloWing pipe materials are approved roi' use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron ASTM D3034 (PVC) ^STM Sl0 (HDPE) ASTM D2662 (ABS) Yes Yes Yes Yes Yes No Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with wate"rfight couplings (Caulder, Femco, or equa".t) "~;'," ~'"'~':'" ,, '.:" A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever requirement applies. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections Will occur as follows: Page 4 Lot 37, Section 8, TI5H, RIW June 20, 2001 The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be baCkfilled before this insp.~ction. The second inspection must be conducted after the:.?iSl~icement of the silt barrier, gravel, distribution lines, standpipes, cleanou~, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the p'r0perty. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre- construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. ,':*r f.~ '.;~' S & S Engineering shall have no liability to the owner or t6 others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR / INSTALLER MUNICIPALITY OF ANCHORAGE • Development Services Department '' Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 Certificate of On-Site Systems Approval Parcel I.D. 05109270 /- / D Expiration Date: 1. GENERAL INFORMATION Complete legal description Barnett Estates Lot 2 Location (site address) Scenic Drive Current property owner(s) Barnett Day phone 441-2664 Mailing address Real estate agent Mike Thomas Day phone 441-2664 6 707 2. TYPE OF DWELLING: �0 0 Single Family (w/wo ADU) n Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) �� ti 3. NUMBER OF BEDROOMS: 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well n Private Septic X Water Storage Holding Tank ❑ Community Well ❑ Community Public Water System ❑ Public Sewer I I Waiver request for: Distance: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 95.60 Waiver Fee $ Date of Payment L(IALI 1(C) Date of Payment Receipt Number /� O55 -3-0 Receipt Number U COSA# OC1a 11a? Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation. based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On-Site staff may visit the site to verify the information submitted. Name of Firm NorthRim Eng. Phone 694-7028 Address PO Box 770724, Eagle River Engineer's Printed Name Steve Eng Date 4/23/19 Sao a. 6. DSD SIGNATURE l' System #1 Approved for bedrooms �, Steve kJ System #2 Approved for bedrooms f s°E. ' ya;d /23!/114(x$ :0 Disapproved b N '00FESSW Conditional approval for bedrooms, with the following stipulations: Lokl((OF f(A4/„(r/���f ON SITE WATER AND WASTEWATER PROGRAM Iffy �Q\� i'eAr SERA�G v•-•ti % Original Certificate Date:, 7 The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Chec'list b,ae sheet COSA Checklist Legal Description: Barnett Estates Lot 2 Parcel ID: 05109270 If more than 1 septic system on lot: COSA Checklist# of Structure served by this system A. WELL DATA ❑■ Well log is filed with Onsite (or attached) Well production at time of test 3 gpm Date drilled 1/418 Water storage tank volume 0 gallons Total depth 255 ft Well disinfected for coliform test? El Yes ❑■ No Cased to 116 ft 0 Coliform bacteria is Negative ❑■ Sanitary seal is functioning correctly Nitrate mg/L ❑t Nitrate less than MRL (ND) ❑■ Wires are properly protected Arsenic ug/L f■❑Arsenic less than MRL (ND) Casing height(above ground) 36 in. Collected by NRimEng Date of flow test for COSA 11418 Date of Sample 3//2ji 9 Static water level at beginning of test ft. Comments B. TANK DATA C. LIFT STATION Age of tank(s) new years ❑ Required maintenance completed Tank type/material Steel Age of lift station years _ Measured operating fluid level in septic tank new Lift station material 51 Standpipes/foundation cleanout per record drawin6 " Comments: Date of pumping new D. ABSORPTION FIELD DATA new Which system tested (date installed) new Adequacy test date new ❑■ ALL standpipes present per record drawing Results ❑✓ Pass For 3 bedrooms Total measured depth from grade 7.5 ft(max) Fluid depth prior to test in Measured depth to pipe invert from grade 3.5 ft(min) Water added na gal ❑ N/A—pressurized field New depth in ■❑ Monitor tubes go to bottom of effective. If not, state Elapsed time min depth into effective ElCode-requiredsoil cover over field Final fluid depth in ❑ System presoaked Absorption rate gpd (Required if vacant for greater than 30 days prior to Any rejuvenation treatment(past 12 months) date of test) Gallons introduced gallons If yes, enter date Comments/Deficiencies: COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100' 0✓ Yes if No ft E Yes if No ft Neighboring Tank > 100' 0✓ Yes if No ft Private Sewer/Septic Line > 25' El Yes if No ft Absorption Field on Lot > 100' ❑✓ Yes if No ft Holding Tank > 100' ❑✓ Yes if No ft Neighboring Absorption Fields > 100' Animal Containment > 50' 0✓ Yes if No ft ❑✓ Yes if No ft Manure/Animal Excreta Storage > 100' Community Sewer Main > 75' Q✓ Yes if No ft E I Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ❑✓ Yes if No ft Surface Water > 100' ❑✓ Yes if No ft Property Line > 5' E✓ Yes if No ft Wells on Adjacent Lots: Absorption Field > 5' ❑✓ Yes if No ft Private Wells > 100' ✓❑ Yes if No ft Water Main > 10' ❑✓ Yes if No ft Community Wells > 200' 0 Yes if No ft Water Service Line > 10' D Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Q✓ Yes if No ft If absorption field is under driveway comment below Property Line > 10' ❑✓ Yes if No ft Wells on Adjacent Lots: Water Main > 10' ✓❑ Yes if No ft Private Wells > 100' D✓ Yes if No ft Water Service Line > 10' p✓ Yes if No ft Community Wells > 200' ❑✓ Yes if No ft Surface Water> 100' ✓❑ Yes if No ft F. ENGINEER'S COMMENTS G. ENGINEER'S CERTIFICATION ....5 f.3F 4, 'r n V '{ ''.....t•.•4 poy 41"I certify that I have determined through field inspections and review irre ..,' ,1 A# of Municipal records that the above systems are in conformance with so* c'r ..173 4 MOA COSA guidelines in effect on this date. :SNI : .. 4 fi ® Steven `,'r , . _43 ' < 'I ei"t(I>,q^ q/Z3/�q COSA Checklist yellow sheet -@V,2,7 '� Lot 1 20' PATENT R.O.W. RESERVE 3 I CHAIN-LINK FENCE I Lx . — x — x — x — x Sx89'55'59"Ex x 299.72' x x J+ x 1 Lot 2 cico I 49,470 s.f. I cn 0 z / o a4: 2.0' CANT / I Z 8.2'x12.0' DECK 1•3 \ w N 109.9 _rrj n '0 35.2] 01 t 1 19.0' ( GRAVEL DRIVEWAY.. 0 .1:71SEPTIC PIPES �N Z S�E�G� (1:I:..'. 7] c �c�\� '24.0' {•..;' •. NR 1 9. 135.6' 30.2' PO�\�S o rn 6.1' PORCH 0.\-6°C- '?' Fz WELL a I . / i' \ ,\00 • I N 89'56'00"W 299.92' \ / I / \ 1 \ 1 I / 1 Lot 56B I I I