HomeMy WebLinkAboutDENALY BLK 1 LT 8b .n ly lock I Lot 8 067-041 -14 MuniCipalitY of Anchorage Development'serVices Department Building Safety Division ~' On-Site Water and Wastewater Program, 4700 S. Bragaw St. P.O, Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW010197 PID Number: 067-041-14 Name: Wastewater System: [] New [] Upgrade Sudsbury & Sons. Inc. Address: 11239 Aurora St., Eagle River, AK 99577 ABSORPTION FIELD Phone: Number of Bedrooms: 696-1610 ' 4 [] DeepT..ch "Shal,owTra,c~ [],ed [] Soil Rating: Total Depth from original grade: LEGAL DESCRIPTION 1.2 G,D~F~ 6.96 Ft. Block: Lot: Subdivision: Depth tn pipe bottom from odginal grade: Gravel depth beneath pipe: I 8 Denaly 2.96 Ft. 4 FL Township: Range: Section: Fill added above odginal grade: Gravel Length: 1.4+!- Ft. 52 Gravel width: Number of lines:IDistance between lines: Well: New Upgrade 5 Ft. Classification (Private, A. B. C): Total Depth: Cased tn: Total absorption area: Pipe Material: Private 201 Ft. 200 FL 520 Fe D3034 & F810 Driller:. Date Drilled: Static Water Level: Installer.. Date Installed: M-W Drilling, Inc. 612512001 50 FL Sudsbury & Sons 612712001 Yield: Pump Set at; I Casing Height Above Ground: TAN K 100+1- G,. unknown Ft.. 2 SEPARATION DISTANCES [] Septic [] Holding [] S.T.E.P. [] Other: ' ~.~_'~'~.~o Septic Absorption Lift Holding Pubtic/Private Manufacturer:. Capacity: Tank Field Station Tank Sewer Line Anchorage Tank 1250 Ga,. Material: Number of Compa~lments: w.li 100'+ 100'+ NA NA 25', Steel 2 S.,facaWatar 100'+ 100'+ NA NA ~ $':'e: Manufacturer:LIFTSTATIO~J Lot u.. 5'+ 10'+ NA NA Gal. I "'g" wa~r ~tam, at; Fo~nda,on 5'+ 10'+ NA NA -~ump o..~,v..t; ~ ~"'1 ecu~nDrai. NA *50'+ NA NA ~ E,ec~ca,,.,pec~en, Rame~,: BENCH MARK *llone known Location end Description: insulation over tank and field Bottom of siding Assumed Ir. levabon: 100 Engin~,~,~Starnp Inspections performed by: KND Engineering Dates: 1't 612712001 _ ~__~;5~'r. .2~, 612812001/ / .. Development Services Departmen.t Appr'o'"v~l la/~/~t---~ ~e~ie~ow) ed and approved / _/~/. /~)~ Date: //-7--O/ ~i?~,;'*,.....,...,.,~,~2~''~' AS-BUILT SYSTEM DETAILS/SITE PLAN Permit S~/010197 DENALY S/D, LOT 8, BLOCK 1 PIDflO67-041-14 ~~ ~ / 40,784 ~~Z O. 94 A C R ~ FINAL GRA~E ~_D= 2G.B~ A-F= 58.4' R /~ SEPTIC ~ ' ~ ~ / ~-F=54.7' ~ / ITANK I~ SEWER ROCK ~~~ O~ ~ PREPARED FOR: SCALE: NTS ~ ~ EAGLE RIVER, AK. 99577 ' S EIELD B~KS C~ ENGINEERING s,~ ~t~[~ KMD 80441 PTARMIGAN BLVD. ~%~~ *~': SEW~O o,m ~/7/0~ EAGLE RIVER, AK 99577-87~6 ' ~ ~ ~s,o~ ~ ~,: ,~ h..,~...?....,.......?.....?.?.~.~.:,~....:...........?,..~...?.~.~?.??:?:~m] *~r~:01065.DWG ~"': 01065 (90T)696-OlII/FAX (90T)696-8111 / Job No.: Permit No.: Project No.: · 01-169 SW010197 ~' NIA Nt-W Drilling, ]:nc. · P.O. Box 110378·Anchorage, AK 99511· · 907-345-4000 · 907-345-:3287 Fax· Groundwater IFeH As-Built & Lolz · Well Owner: · Legal Description: Sudsbury and Sons Lot g, Block I Denai¥ Subdivision r:zo~le River, Alaska · Use of Well: Domestic Construction · Hole Depth: 20 I' · Casing Size: · DrilIMethod: · Air Rotary 6" · Cased To: 200.02' · Well Completion- Open end X Screen ~ Perforated · Screen/Perforation description: None · Material: Perf. Method: A 53 Steel · Grout Notes: Well dry grouted with 12 sacks- No. 8 bentonite granules · Well Development: Method: Air surge Notes: · Static water level (SWL) 50.05' (above) ~ ..... 9 top of casing (TOC). · Wellyleld test at ! 00+_ gallons per mlnute (GPM)/£al!ar~ wlth ! 00% of drawdown (DD) from static level ($WL). · Method: Air I hours · Date of completion: 25 June 2001 · Pump Install: Well Log Depth in feet from top of casing. Details of formations penetrated? size of material, color and hardness. 0 TO .2 Casing stickup 2 TO 6 Soil With cobbles: brown 6 TO 12 Gravel and sandy silt: gray 12 TO 14 Gravel and sandy silt: gray, damp 14 TO 57 Gravel: dry 57 TO 64 Silty sandy gravel: .,damp 64 TO 180 Clay: gray, stiff 180 TO 201 Sandy gravel TO TO TO ~//"'~ ~ To a, TC) ' ~"~ TO ~r~ified TO ~ate ~To'a. 814 & 97:3 MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jun 19, 2001 Expiration Date: Jun 19, 2002 Permit Number: SW010197 :,Legal Description: ,DenalY Subdivision Block 1 Lot 8 :' Design. Engineer: 0070 KND Engineering Owner Name: Sudsbury & Sons Owner Address: 11239 Aurora St. Eagle River, AK 99577- Parcel ID: 067-041-14 Site Address: NHN Denaina Dr. Lot Size: 41172 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: r~ Disposal Field r~ septic Tank [--] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. ~:5~:The following special provisions. ' ' '; ' ~-, !, PRIOR TO CONSTRUCTING THE WATER WELL, THE WELL' DRILLERSHALL SUBMIT ~ DRit~LIN'GiPLAN TO i. THIS OFFICE. THIS PLAN SHALL SHOWHOW THE WELL CONSTRUCTION WILL PREVENT ALL LEAKING i; 'THROUGH THE CASING ANNULUS FROM THE CONFINED AQUIFER.. Received By: Issued By: Date: ~ ",/9 "' ~:Tj' Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P,O. Box 196650 Anchorage, AK 99519-6650 www.ci,anchorage.ak.us (907) 343-7904 ON-SiTE SEWER/VVELL PERMIT APPLiCATiON FOR A SINGLE FAMILY DWELLING Parcel I.D. Ob7" ~"//~/N Permit Number swOIO I ~ 7 Property owner(s) Sudsbury & Sons, Inc. Mailing address (1) 11239 Aurora St.,.Eagle River, AK 99577 address (2) D Legal description (Lot, Block & Sub'd.) Denaly S/D, B1, L8 Legal description (Section, Township & Range) Lot Size 41,172 Acres/Sq. Ft. Day phone 696.1610 __.Zip Code Number of Bedrooms 4 THIS THIS APPLICATION IS FOR: Sewer Only [] Well Only [] Sewer and Well [] Water Storage [] Sewer Upgrade [] PROPERTY CONTAINS: Hot Tub [] Jacuzzi [] Swimming Pool [] Water Softening Unit [] Therapy Pool [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: 7 ~-'//~'~-'' Date of Payment: Receipt Number: ~"~'~' (Rev, 12/00) Waiver Fees: Date of Payment: Receipt Number: ]~D ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 June 7, 2001 Munidpality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: New sewer & well permit - Denaly S/D, Block 1, Lot 8 Gentlemen: The owner has requested we proceed forward to obtain a well and septic permit on the subject lot. On May 31, 2001 we dug one testhole for the proposed system. The results of this test are attached. The general slope of this lot is from northeast to southwest at a grade of approximately 3 - 8%. An individual well will serve the lot. We propose to install a 5' wide shallow trench for the proposed 4-bedroom house. Water was not encountered during the excavation or monitoring. There are no public or private wells within 200' of our proposed system location except as noted. There is no surface water within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, ](~ID Engineering Attachments: On-Site Well and Sewer Application Wastewater Absorption System Details/Site Plan Soils Log/Percolation Test ELL & /ASTELFATER DENALY DISPOSAL SYSTEM LOT 8, BLOCK 1 DETAILS/SITE PLAN 7 40,425 SF 0.93 VACANT VACANT 8 41.172 S~ o. g5 ACRES 4 40,224 SF 0.92 ACRES 22 40,189 SF 0.92 ACRES VACANT 40,542 SF 0.93 ACRES VACANT BLOCK 9 40,784 SF 0.94 ACRES NO PUBLIC VELL$ VITHIN 200' PROPOSED SYSTEM. NO PRIVATE VELLS VITHIN PROPOSED SYSTEH EXCEPT AS I~TED. NO SEPTIC SYSTEHS VITHIN PROPOSED VELL EXCEPT AS NOTED. DESIGN DETAILS 4 BDRM X 150 GPO = 600 GPO 600 GPO/12 GPO PER SQ. FT, (1,74 MIN/IN}= 500 SO. FT (500/5'(V)) X .5(RF) (4.0' GRAVEL) = 50.0 FT. TRENCH USE 2 TRENCHES - 50 (L) X 5' (W) X 4.O'(B) Totot depth oF system is 7.0' ?rom origino! 9rode. Toted depth oF grovet betow distribution pipe is 4.0' . NDTES: 1. CONTRACTOR & ENGINEER TD VERIFY INTEGRITY DF SEPTIC TANK AND REPLACE AS REQUIRED. INSULATE TANK IF <4' COVER. 2. INSULATE TRENCHES VITH 2" HD BURIAL FOAM. 3. CONTRACTOR VILL ENSURE MINIMUM 2X SLOPE INTO SEPTIC TANK. 4. ADDITIONAL FILL VILL :BE ADDED OVER SYSTEM TB ACHIEVE MIN. 3' COVER IF REQUIRED. 5. CONTRACTOR ;/ILL ENSURE ALL SEPARATIONS TO ADJACENT ~/ELLS & SEPTICS. PREPARED FOR: SUDSBURY & SONS, INC. 11239 AURORA ST. EAGLE RIVER, AK. 99577 (907) 696-1610 FIELD BOOKS BO..~DAR~ STAK~ ASO~T: SEWARD rILE:: ~ ~c: 01065.DWG COMPUTED: DRAWN: Sc(lie: 1°= 100' PAGE 1 OF 8 ENGINEERING c~£cxco: KMD DAm 6/7//01 cram, SW363 aoe No,: 01065 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (9071696-6t''/FAX (907)696-8111 ED) WASTEWATER DENALY S/D, LOT 8, BLOCK 1 DISPOSAL SYSTEM DETAILS PROPOSE D 4 BDRM SFD O. 95 ACRES PROPOSED 1850 GAL S.T. CO TH jFCO ~o M1 MT VACA PREPARED FOR: SUDSBURY & SONS° INC. 11839 AURORA ST. EAGLE RIVER, AK. 99577 (9D7) 696-1610 FIELD BOOKS STAKING: SEWARD ^c~ r~: 01065.DWG CO~I~J 1'[0: c~rcxto: KMD 6/7/01 SW363 ~ ""'" 01065 Scare'- 1'= 80' PAGE 8 DF 8 ~[D ENGINEERING 20441 PTARMIGAN BLVD. [EAGLE RIVER, AK 99577-8736 `.v~v~>~v~v~:~:~v:~v~<~:~:~<~?~<~v~???~:~?:~.~:~ 9071696-611 I/FAX (9071696-8111 ~D ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 SOILS PERCOLATION TEST Performed for: Sudsbury & Sons, Inc. Date Performed: 05/31/01 Proiect: Denaly S/D, Block 1, Lot 8 TEST HOLE # 01-1 2- 3- 4- 5- 6- 7- 8- 9- 10- 11- 12- 13- 14- 15-~ 16- 17- 18- Depth Org - soft, brown, moist loam- GP - firm density, gray sandy gravel, moist, minute trace ' of silt, w/cobbles to 8" & SM lenses up to 4" B.O.H. SEE ATTACHED SITE PLAN FOR HOLE LOCATION Was Ground water encountered? NO What depth? N/A Depth to water after monitoring? DRY Date? 06/07/01 Reading Date Gross Net Depth to Net Time Time Water Drop 1 6/1/01 1:00 6" . 2 1:10 10 rain dry 6" 3 * 1:11 - 6- . 4 1:21 10 rain dry 6" 5 * 1:22 - 6" 6 1:32 10 rain 15/16" 5 14/16" 7 * 1:33 - 6" 8 1:43 10 min 3/16" 5 13/16" 9 * 1:44 - 6" 10 1:54 10 min 4/16" 5 12/16" 11 * 1:55 6" . 12 2:05 10 min 3/16" 5 13/16" · Water Added 19- 20- HOLE PRESOAKED PRIOR TO TEST Percolation Rate 1.74. (min/in) Perc Hole Diameter , Test Run Between ~ feet and. 4 feet 11 I, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in effect on this date. ..cb Municipality of Anchorage Development Sen/lees Department' Building Safety Division ' On-Site Water and Wastewater prOgram · ~4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650' www.ci.anchorage.ak, us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 067-041-14 GENERAL INFORMATION Complete legal description ]',n t-. Location (site address or directions) HAA# (~ L/-O '1, cl 7 Expiration Date: - / - O 99577 Current Property owner(s) Deirdre Moore Day phone 622-2520 Mailing address Lending agency same Day phone Mailing address Real Estate Agent Donna Alderman Day phone 6Rq-6&6R Mailing Address Un/ess otherwise requested, HAA will be held by DSD for pickup. NUMBER OF BEDROOMS: 4 TYPE OF WATER SUPPLY: ' Individual Well Individual Water Storage Community Class Well Public Water System TYPE OF WASTEWATER DISPOSAL: · Individual Omsite :~ Individual Holding tank -I--I Community On-site I'"l · Public Sewer r-] r The Municipality of Anchorage DeVelopment Services Department (DSD) Issues Certificates of Health Authority ApprOval (HAA) based only uPOn the representations 'given in paragraph 4 by an independent prOfessional civil engineer registered in the State of Alaska. Certificates of Health Authority ApprOval are required for the transfer of title (except between spouses) for prOperties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for prOperties served by a pdvate or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a pedod of up to one year with valid water samples.) · Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the prOfessional engineer's work. STATEMENT OF INSPECTION BY. ENGINEER~ ' r. As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,' based On procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe~ functional and adequate for the number of bedrooms and type of structure indicated herein. ! further vedfy that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Finn S & S Engineering Address 17034 N. Eagle River Loop Ste. 204~Eagle Engineer's Printed Name Robert C. Cowan bedroomsi' DSD SIGNATURE ~ Approved for .L~.. 'Disapproved. Phone 694'2979 River, AK 99577 Date ,-%--///'7 -':.; tI .*' ,.,~ ~ : --BERT % Conditional aPl~roVal for' __ bedrooms, with the following stipulations': Additional Comments Attachments: HAA Checklist Septic System Advisory Well Fiow Advisory Maintenance Agreements SupPlemental Engineer's Report Other By: (Rev. 01/02) Original Certificate Date:. i 01-o ¥ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: LO1"¢ i ~'~0(--~ 1 ! ~7~/~-! ~' ~'/~"~, WELL DATA Co Well type ~ F If A, B, or C provide PWSID # '"'- Date completed ~ ('~/O ( Sanitary seal (Y/N) .~ Total depth ~ ! ft. Cased to z~ '/' ft. FROM WELL Date of test ~ / '~_...~" ! Static water level ~-~7 ft. Well production / O~ '~' . ,-- g,p,m, WATER SAMPLE RESULTS: Coliform O colonies/100 mi. Arsenic: O,l~,Z' mg./l. SEPTIC/HOLDING TANK DATA / Tank Type/Materia / <J Tank'size .~.,~)gal. Number of Compartments Foundatiori cleanout (y/N) y Depression over tank (Y/N) ·~.~/~ /_L' ~j'~ j./ Date of pumping ~f'[~,[O-~ Pumper Length ~/ ' ft. Width Total depth ~ ~ ft~ E~. a~sorption area -- Date of adequa~ test Fluid depth in absorption field before test ~ in. Elapsed Time:~0 min. Finalfiuid depth 0 in. Any rejuvenation treatment (past 12 mo.) (YIN & ~e) Nitrate l~/z~-~'~mg ,/], Well Log (Y/N) '~'/' Wires properly protected (Y/N) ~/'" Casing height (above ground) AT INSPECTION ~"~t2 Monitoring tube ~ Results (Pass/Fail) ~ Water added~,? gal. g.p.m. Other bacteria Collected by: //~ ' colonies/100 mi. Date installed ~, Cleanouts (Y/N) High water alarm System type ~' H. '7--K~-Lc-/''J Gravel below pipe ~-~ ft. Depression over field /'J For +.., bedrooms New depth I ,,in. Absorption rate >= ~ OO g.p.d. If yes, give date .! D.. LIFT STATION . ! i :*i'i.:il~' : ~ j ,, ~i~)i Date installed Size in gallons ~I -, Manhole/AccesS (Y/N) · . ," "Pump on", level at "Pump o~ level at'.' !,~ in.j High water alarm level at : Datum " Cycles tested! i i Meets alarm & circuit requirements? E. SEPARATION DISTANCES ' SEPARATION DISTANCES FROM WELL ON EOT. TO: J; J ' l..(~)i~ 1 ~ lOin adjacent lots / ~:)l~ ! d- On adjacent lots :[ (~ O / //'- / /'~ /1-r'!.. ' ' PUblic'sewer manholelcleanout. ~¢J, SeW~/septic service'line .· '~'~' ~ H~ldin~ tank . SEPARATION DISTANCES FROM SEPTI'CI~ TANK ON LOT TO: / '' "'' '! t1,.]...' . :, ~' Buildingfodndation I I. i: L,/·..7- Pr°p?rtyline I~' ~i , . Absorption field Watermain It.' . Wai~r Service line /I'/..Z. Y-- Surface water/,v.,.._... Wells, on,a~Jjacent . i : "' SEP~AP,~, ,TION DISTANCE FROM ABSORPTION FIELD ON LOT TO: : , . -- · ; I I' .- ~ ' ' I, I :: ? , J [ Property line/ ~., ~T' Building foundation', /l (~), ~ Water main ~'~ ~ ~l I ~ ,. ,,: ~ , ,~ ~. Water Se~ice line ) ~ ~ Su~acewater ] ~,. ~: Drive.y. parking~ehicle storage. / J~ j I ce~i~ ,hat lhave dete~ined through field inspection~ and ~' ~~~~ review o[ Mumc~pal records that the above ~ystems are ~n ~ conformance w~th MOA H~ guidelines m effect on th~s date? ~ [ 'm,~, . :. - ~: . -~': ~ ~' ~ , . - EngineersPrintedN~m~ ~0~,~. C.~ 4 ~ ~2~t",..~ . ; ..... ~'~ ,, H~hee ~. ' , , Waiver Fees , ',~ ~ /o ~,.- ~ .,..- ~ Date of, Payment ~l .I ~ ~te'of Pa~ent . Receipt Number O ~ ~ ~ ~:~' !1~ R ;eiptNumber . (Rev. 1~01) ' ' , [ ~ '] '' [~ 05-13-04 08:12AM FROM-CT&E ESI, SGS ENV SERVICES 9075615301 T-322 P.02/03 F-944 SGS Ref.# Client Name Project Name/~ Client Sample ID Matrix 1042280001 S & R Engineering Lot 8, Block 1, Denalv S/D Lot 8, Block 1, Denaly Drinking Water Sample Remarks: All Dates/Times are Alaska Standard Time Printed Date/Time 05112/2004 6:50 Collected Date/Time 05/05/2004 12:46 Received Date/Time 05/05/2004 15:12. Technical Director ~, Step,In2. Ede Allnwnblc Prep Analysis Panunet= Results PQL Units Method Container ID Lirp{rs D~c Date Init Metals Department Arsenic 0.00200U . 0.00200 mg/L EP200.9 C (<---0.01) 05111/04 05111/04 KAV~ ~aters Department Nitratc-N 0.478 0.100 rog/L, EPA 300.0 B · (<=l 0) 05/06/04 JM[ Microbiology Laboratory Total Coliform 0 col/lO0mL' SMI8 9222B A (<=1) 05/05/04 DK( Time: 10:'35 AM To: T&mmy ~ 69~-1211 page: "002-002 v 1G O1 12:29p 'SUDSBURY~S&SOMS 90? GgS 1GI~ p.G ASBUILT ~ $]F, CI..RD & ASSOC.TA T- HEREBY' CERTIFY .THAT ] HAVF ~..[AZE, S LAND .~,71t.~TH'G 694-0829 ?IiJII,;AIEU. IT IS THE REsPONsIBIUTY OF THE _O~._.l~ TO DE'rERMIN£ THE: iLrXI~IT..NC~ OF ANY ISlON PLAT. UN ' I · --,, ,,'~,A n~ BE USED H0CLD Parcel I.D. 067.041-14 Municipality of Anchorage Development iServices Department Building Safety Division On-Site Water and Wastewater Program 4700 ;South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 · CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Expiration Date: GENERAL INFORMATION : ...-, . Complete legal descdption? ' DENAL¥:L0T 8, BLOCK 1 Location (site address or directions)' NHN 0enaina Drive, Eaqle River, AK 99577 Current Property owner(s) Mailing address Lending agency Sudsbury & Sons 11239 Aurora St., Eagle River, AK 99577 Day phone 696.16i0 Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise 'requested, HAA will be held by DSD for pickup. NUMBER OF BEDROOMS: 4 e TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class .~ Public Water System Well TYPE OF WASTEWATER DISPOSAL: [] !ndividual On-site [] [] Individual Holding tank [] [] Community On-site [] [] Public Sewer [] The Municipality of Anchorage Development services Department (DSO) Issues Certificates of Health Authority Approval (HAA) based only upon the'representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska, Cedificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a Single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) CertifiCates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER ' As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and-adequate for the number of bedrooms and type of structure indicated herein. I further vedfy that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Phone. '696-61il Se Name of'Firm KND Engineering ' Address 20441 Ptarmiqan Blvd. Eagle River, AKi 99,577 Engineer's Printed Name Kenneth M. Duffus L]L "bedrooms. DSD SIGNATURE ~ Approved for Disapproved. Date. 11107101 Conditional apP'roVal for bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist septic System Advisory Well Flow Advisory X Maintenance Agreements SuPPler~ental Engineer'sReport Other Original Certificate Date:., (Rev. 12/00) DeveloPment Services Department i ~ ~ i~ . Building Safety Division '.' · , on-Site water & Wastewater prOgram :: .,; : '4700 SOuth Bragaw St. : P.O. Box 1196650 Anchorage, AK: 99519-6650 ~' '~ :~ www'ci'anch°rage'ak'us ": :; (907) 343'7904 ..HEALTH AUTHORITY APPROVAL CHECKLIST f~; :i' : parce iD: 067.041-14 ;cription: DATA' - Legal D(~s( Denaly Lot 8, Block A. WELL : , -' . : ...... l! ~_~ Well type privet : 'I!: i': Date completed 612512001_ · ..... ry ,_ _.. ~ji'_,L' :20i /0tel Oe~pt!l: . · , ,' ,"! j,i Date Of t,,est: ·.. . .6125101 ,. ,:. static water level 50 ft. Wires properly Casing height AT INSPECTION IN) Y. !ot~ted (YIN) Y , )ove ground) - 2' Well production : ~ .100+1- g.p.m wATER SAMPLE RESULTS: . · · , ~ ' :' ' Coliform Ji :0 :coloniesll00 mi. .Nitrate 0.63_ mg.ll. : l:i ~ Date of's~mple: ~013tI0~, . .Collected by: KND Engineerin.q "' ~ B. SEPTIC/HOLDING TANK DATA , I~ I~ ~';. Tank .'rYis~/Materlal Anchora.qe Tank I Steel' ~ 'I ~ Date installed' It ]~" i'.~6128101 yank size: 1250 _- gal. Number of CompadmentS2 Cleah'~t~' '~Founda!i0n cle.an°uty--~epressl0n over ..... tank~High water alerm;,. ~NA Date ~! ~;~ing-''NA;''newtanldsYstem:['-Pumper ~' i;:'i'[~ ~ ': C. ABSORPTION FIELD DATA. " :: . 'r.! !~t/~ ' ~ ~ '~ ' ': ' ' - System type Shallow Trench 'il! ~, ~,. 612710t" Soil rating ig.p.d.Ift~ or'ft2/~drm) 1.2j Date:installea . ~ ~ i~~ ! '~i .. ,~ : '.-, · , ~'.': , ~ ~!. ~[ ' : · ;,[I, ,,, :-. :,, '%,~,,¥'," .' :ft : Gravelbelow, p~pe 4 ff. :;, Leng~n oz :: ,~..~.~,u,,,., · , " Total' ~lel~th~' 7 ft. 'Eft. absorption ~rea '~520-ft~ Monit°ring tube ~Y_..: .Depress~o.n o, ver field N Date '~ adequacy test NA-news¥{tem: :. Results (paSs/Fail) Pass For I bedrooms Fluid ~epth~ in absorption field be!oreltest 'in:: Water added '::gal',tlI!' .:' New' depth Elap;~dt'Tilme: :rain. :.. Final:fluid depth ., in.'! ' Absorl:)tion~ rate >= . 1 ' ' ! lfYes, give ~late treatment (pastil2 mo.) (YIN & type) Any .mjdvenation ill ,' oth~el~!~blacteria 0 c01onies/100ml in. . g.p.d. D. LIFT STATION Date installed NA "Pump on' level at in. Datum E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot 100'+ Absorption field on lot t00'+ Public sewer main 75'+ Sewer/septic Service line 25'+ Size in gallons ~ Manhole/Access (Y/N). ?ump off,, level at __ in.High water alarm level at Cycles tested Meets alarm & circuit requirements? On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout 'Holding tank - 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT,TO: Building foundation 5'+ Propedyline. 5'+ '-, Water main 10'+ Water service line 10'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Water Service line Curtain drain 50'+ COMMENTS Building foundation -10'+ Surface water 100'+ Wells on adjacent lots 100'+ G. ENGINEER'S CERTIFICATION -'. I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Kenneth M. Duffus Absorption field 5'+ Surface water ~00'+ Water main 10'+ Date .1tl0710t 100'+ Driveway, parking/vehicle storage-25'+ in. HAA Fee $300 Date of Payment ReceiPt Number (Rev. 12/00) Waiver Fee $ Date Of Payment Receipt Number riOV-07-01 Og:46AU FROU-CT&E ENVIRONI~NTAL SRV ~d~t~. CT&E Environmental Services Inc. 9075615301 T-g35 P.02/03 F-563 1017626001 KND Engineering Denal¥, Lot 8, Block 1 Denaly, Lot 8, Block 1 Drinking Water CT&E Ref.# Client Client Name Printed Date/Time I 1/05/2001 Project Name~ Collected Date/Time 10/31/2001 15:30 Client Sample ID Received Date/Time 10/31/2001 16:30 OrderedMatrix By' TeehnlcalD~,~j~S;p~hen~ PWSID 0 Rclcnse~[~~,,~ W/ Sample Remarks: Allowable Prep Parameter Results PQL Units Method Limits Dam Date Init Waters Department Nitmtc-N 0.631 0.500 mg/L EPA 300.0 (<:10) 10/'31/01 M£crobiolo~y Laboratory Total Coliform 0 col/100mL SMI8 9222B (<1) 10/31/01