HomeMy WebLinkAboutBROOKS VANDERWOOD LT 48Abrooks
Vanderwood
Lot 48A
#051-104-68
' O
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Waste~ter Program, 4700 S. Bmgaw St.
P.O. Box 196650 Anchorage, AK 99519~650 Page ~ of~
~.ci.anchorage.ak. us (907) 343-79~
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: 5 ~ O I ~ i 3~' PID Num~.
"~m':'~rO/~n Lee WastewaterSystem: ~New DUpgrade
~dress:
;~0~ Ht//~gaS?re~ ~'~/~ ?~Ed7-dl~, ABSORPTION FIELD
LEGAL DESCRIPTION ~"""""~: 0.~.o,.,.
Fl. Ft.
Drillen
s.,.: ICasi~ Height
.,. ~ TANK
Septic Abso~tion Lift Holding Publi~dvat~ ~a%~, ~ Capac~ ~ ~0'
· an~ .~e. S~a~on Ta.~ S.we, U.e ~;~b;.4 ~ ..,.
Material: ~
5~'lO'~X ~,z.: ~ .
LOl Line ~1. ~
.u~.,,o~ ~' 5~' "~-"'-"-
~ ~ in.J ~ in.
Pu~
CunainDrain / ~ ~'1'' ~ ~ M~ El~llnspe~onspe*~edb~
Remarks:
[~,sr~ L,~,~ ~,,~ 7~c~ BENCH MARK
En '
: ~%~ ,.,,-' .',.,?~-,~
S & ~ ENGINEERING
Inspections pedormed by: 17034 Eagle Rl~e~Lo~...~...~,...="g~es: ~" 6--12-01 .,
~.,,..,.r..,..-, 2"~ ~--JO--O/
Development Se~ices Depadment Approval
Reviewed and approved by / Da,e: ~ -~O/
(R~. I=~) 'it. / c ;~o' ~-
PER~[T NO. SW01 01,34 PAGE 2 OF 5
DEPARTMENT OF HEALTH ANIJ HUM:AN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.O. ]~ox 196650 I_Anchoro§e, ALosko 99519-6650 ·Tel. e~hone~ :::]43-4744
ON-SITE VVASTEWATER IJISPOSAL SYSTEM AND/OR WELL INSPECTION
REPORT
LEGAL LOT 48A, BROOKS-VANDERWOOD S/D P.I.D. No. 051-104-68
I
LOT 1 LOT 2
///2/co,./ / \ \ ~ ~_
~///// /¢'/ X ~ ',
· I
. 100' WELL RADIUS · "
I
~i~...~ .. :......,.~:~.
~7' ~":.~'*.
LOT 4~B '~//~,~
:~..~:~.,~ ..... ~ .....
PERMIT NO. SW01 01,34 PAGE ,3 OF 3
· Mu_ni_cip.a_[i~y_o.F Anchoraae
DEPARTMENT uP HI---ALTH AND HUIVFAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.D. Box 196650 eAnchoro, ge, Ato~sko, 99519-6650eTetephone: 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION
REPORT
LEGAL LOT 48A, BROOKS-VANDERWOOD S/D
P.I.D. NO. 051-104-68
FINAL
GRADE y2" INSULATION
FINAL GRADE
GRADE
A B
FCO 29.0' 28.5'
ST1 41.0' ,38.5'
ST2 47.5' 45.0'
DBL1 51.5' 49.5'
DBL2 5,3.0' 50.5'
C01 67.5' 89.0'
MT1 77.5' 99.0'
C02 90.5' 80.5'
MT2 90.0' 75.5'
WATER FOUND ® 86.8'
84.3' B.O.H.
Munlcipalily oi Anchorage
DEPARTMENT OF HEALT~ & HUMAN SERVICES
825 "L" Slreet. Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
DATE PERFORME
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
2O
COMMENTS
.T.~$
WAS GROUND WATER
ENCOUNTERED?
IF .YES, AT WHAT
DEPTH?
Deplh to Waler After
Monllorlng? Dale:
Re~ding I Date
--I
I / / I
PERCOLATION RATE
TEST RUN BETWEEN
Gross Net Depth to
Time Time Water
Net
Drop
10' V'4-
(0
0
(minutes/inch) PERC IIOLE DIAMETER ,
FTAND ·4 FT
· ..'/ 1..~ //
PEnFORMED BY: ~;v~r L~p Roa~ ~o. ~ . - . ~ CEnTIFY THAT
T~IS TEST WAS PERFORMED IN
72-~8 (Rev. a/85}
MUNICIPALITY OF ANCHORA GE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: May 29, 2001
Expiration Date: May 29, 2002
Permit Number: SW010134
Legal Description:~ BROOKS VANDERWOOD LT. 48A
Design Engineer: 0003 S & S Engineering
Owner Name: CAROLYN LEE
Owner Address: 20838 HELLUVA STREET
CHUGIAK, AK 99567-6128
Parcel ID: 051-104-68
Site Address: 020838 HELLUVA ST
Lot Size: 49520 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
r~ Disposal Field [--] Septic Tank [] Holding Tank [--] Privy
r-~ Private Well
Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorptiOn system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
SEPTIC TANK SHALL BE EXPOSED AT THE TIME OF CONSTRUCTION AND VERIFIED FOR INTEGRITY.
Received By:
Issued By:
Date: ~'-~ ~ -a (
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Permit Number ,SWO I 0134
Property owner(s)
Mailing address (1)
~address (2)~-08~8 ~-.Z/UlJ~
Legal description (Lot, Block & Sub'd.) ~.o'~
Legal description (Section, Township & Range)
Lot Size ~,~-~ ~
4':/, 'ZO
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Day phone ~7~- &J--O 5
Zip Code ~ 7-~ / 28
Sewer Upgrade
Number of Bedrooms
"~ Well Only []
'[] Water Storage []
THIS PROPERTY CONTAINS:
Hot Tub r'-I Jacuzzi
Swimming Pool r"'] Water Softening Unit
Ther';'py Pool r-I
I certify that the above information is correct. I fudher certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
_ 17034 Eafll~ River Loop Road, No. 2~
(Signature of properly owner or authorized agent) Eagle River, Alaska 995~
Permit Fees: '"1~
Date of Payment:
Receipt Number: o 0
(Rev. 12/00)
Waiver Fees:
Date of Payment:
Receipt Number:
~-~ May 8, 2001
SEWER &WATEn
MAIN EXrENSIONS
SEWER&WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PtAN~
$OILTEST
PERCOLATION
TEST
STRUCTURAL&
MEcHANIC, N.
~N~PECTIONS
ON SITE
W~TEWATER
ExSPOSAL SYSTEM
DESIGN
ROBERT C. COWAN, P.E.
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
MUNICIPALITY OF ANCHORAGE
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 48A, Brooks-Vanderwood S/D
It is requested that you issue a permit to upgrade a septic system to serve the existing
three bedroom dwelling on the referenced property.
A test hole was excavated and a percolation test was performed. The approximate location
of the test hole is located on the attached site plan. At the time of excavation 3/20/01 water
was found at eleven feet indicating a drainfield bed design was necessary. An additional
test hole is proposed at the time of excavation.
We do not anticipate any adverse effects on neighboring wells, septic systems, reserve
areas or drainage patterns by the installation of the proposed septic system. The
construction of this system will not prevent any future development on any of the adjacent
properties.
If you require additional information, please contact us.
Sincerely,
RCCOhm
Enclosure
7034 NORTH EAGLE RIVER LOOP ~ SUITE 204 4 EAGLE RIVER. ALASKA 99577
[~'~!~___~) DEPARTMENT OF HEALTH & HUMAN SERVICES ¢"'~ ""' '~'~'~ ~,-~-' '"' ~' ;{,!
~ · 825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG m PERCOLATION TEST .,. -_ ...................
LEGAL DESCRIPT,ON: ~ Townsh,p. Range. Sect,on: '
/
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
SLOPE SITE PLAN
19
20
WAS GROUND WATER
ENCOUNTERED?
,F yes. ATW.AT / / /
DEPTH? pO
Depth to Water klter I;
MonitorinD? Dale:
Reading Date Gross Net Depth to Net
~/~1/~ Time Time Water Drop
~o ~ o ~/4.. ~,,
PERCOLATION RATE . ~ (minutes/inch) PERC HOLE DIAMETER
TEST RUN BETWEEN '-~ FT AND 4 FT
COMMENTS
PERFORMED BY: ~7~dw :=,~.c~ .~.;'.'~." ---r ~ ........ CERTIFY ~HAT THI~TEST WAS PERFORMED IN
72-~8 {Rev. 4/~)
sEwEn J, W,(T En
L~u~ EXtENSions
SEWER&WATER
IN~PEC110~
SOl 1EST
1ESt
~PECTt~
W~T~ATER
~SIGN
ROBERT C. COWAN, P.E.
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL sPECIFICATIONS
CIVIL ENGINEERS
(907) 694-297g
FAX (907) 694-12t t
REFERENCE: Lot 48A, Brooks-Vanderwood Subdivision
May 8, 2001 ,
GENERAL:
The scope of this project includes the verification and / or installation of a
1250 gallon septic tank and an absorption bed to serve the existing three
bedroom residence located on the referenced property.
Construction shall be in accordance with tile approved site plan and design
drawings, Municipal permit or ADEC Authority to Construct with any
special provisions or conditions, and all applicable State and Municipal
Wastewater Disposal Regulations.
The contractor shall be responsible for obtaining any necessary underground
utility locates.
· Unless specifically agreed otherwise, the property owner shall be responsible
for final grading areas subsequently depressed from soil settling. On all
leachfield mound systems, the property owner shall be responsible for
ensuring a satisfactory vegetation growth over the mounded area.
Contractors installing wastewater disposal systems must be certified by the
Municipal Health Department or ADEC if required, for system installations.
Owners installing their own systems must also receive prior approval from
the Municipal ttealth Department.
sEPTIC TANK iNSTALLATION:
A septic tank is to be constructed by a certified septic tank manufacturer.
Construction Shall include two 4" cleanouts for pumping access.
The septic tank shall be stifficiently bedded to prevent settling or shifting of
the tank.
17034 t~ORTH I~GLE RIVER LOOP ~ SUITE 204 ~ EAGLE nIVEIq. ALASKA 99577
Page 2
Lot 48A, Brood-Vanderwood S/D
May 8, 2001
3. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade.
4. Septic tanks installed with less than 4 fi. of cover shall be insulated.
Se
A foundation cleanout shall be installed one to four feet from the building foundation. In
the line between the tank and the leachfield there shall be two adjacent cleanouts. These
cleanouts shall be located on undisturbed soil not mOre than 10 ft. from the tank. The first
cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to
clean toward the septic tank.
Final grading over tile septic tank shall be such that a positive slope exists away from the
septic tank.
LEACItFIELD BED INSTALLATION:
o '
Excavate the proposed Bed Area to the depth shown on the design. The bottom of the
excavation shall be within 2 inches of level. If the bottom of the excavation becomes
smeared, it must be raked or scratched (ruffed-up) before gravel or sand placement.
If a sand layer is required, place sand over entire excavation to the required depth sl~0wn on
the design. The top of the sand layer must be within 2 inches of level.
Sewer rock shall be placed Uniformly throughout the entire bed. Perforated distribution
pipe must be installed level with perforations down. Gravel depth below the perforated pipe
shall be a minimum of six (6) inches. Gravel depth above the perforated pipe shall be a
minimum of two (2) inches. The,total gravel depth throughout the entire bed shall be a
minimum of twelve (12) inches.
The perforated distribUtion pipes must be no more than six :feet apart. The distance between
the outermost perforated distribution pipes and the sidewall of the absorption bed must be
no more than three feet.
o
Silt barrier material must be installed between the final gravel layer and the native soil
backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill.
Monitor tubes shall be of four (4) inch diameter, installed at tile locations shown on tile
design, and extend a minimum of 12 inches above final grade. The portion of the
monitoring tube extending through the gravel depth shall be perforated six (6) inches below
the bottom of the horizontal distribution lines. The monitoring tube should not extend
below the bottom of the gravel surface.
Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation
must be installed When the backfill depth is less than thirty-six (36) inches. The finished grade
over tile bed must be mounded to prevent the formation of a depression after settling.
Page 3
Lot 48A, BroodoVanderwood S/D
May 8, 2001
8. A mound system is to have the upper six inches oftop soil and be seeded for vegetation.
MINIMUM MATERIAL SPECIFICATIONS:
Any septic tank proposed for installation must be constructed by a Municipally approved
septic tank manufacturer.
The following pipe materials are approved for use in septic system installations in the
Municipality &Anchorage:
Type of Pipe Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
o
Use of a type of pipe other than listed above must be approved by tile inspecting engineer.
Insulation shall be at least 2" thick extruded direct burial polystyrene (Doxy Chemical
Company Styrofoam HI or equal).
Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or
equal).
o
A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed
between the final leachfield gravel layer and the native soil backfill.
All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the//200 sieve.
When sand is being used as a filter material, its gradation specifications must conform to
current MOA or ADEC requirements.
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of tile
wastewater disposal system. These inspections will occur as follows:
1. The first inspection must be conducted after the excavation ofditches, pits, trenches,
or beds and before the installation of any gravel. A septic tank may be set in place,
but may not be backfilled before this inspection.
Page 4
Lot48A, Brood-VanderwoodS/D
May 8, 2001
The second inspection must be conducted after the placement of the silt barrier,
gravel, distribution lines, standpipes, cleanouts, and insulatiOn, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading of the property.
Often there will be more than these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer
is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction
meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any
way the contractors activities.
The owner shall contract with the contractor to perform the work outlined in these specifications
and plans and in accordance with the attached MOA permit or ADEC Authority to Construct.
There will be no contractual arrangement existing between the contractor and S & S Engineering.
S & S Engineering shaft be the owner's representative and will inspect the work as stated
above to document the contractors activities. Final acceptance of the contractors work rests
with the owner.
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the contractor to
carry out the ~vork in accordance with these construction documents. S & S Engineering;s
inspecting engineer will not be responsible for the construction means, methods, techniques,
sequence, procedures or the safety precautions incident to this project.
CONTRACTOR / INSTALLER
~f e~-'~ ~'~e- ~ DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
~ ~[~.E']] ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL DESCRIPTION
LOCATION
NO, O~DROOMS
~. DISTANCE TO: ~ ~ J Abso:~n~rea Dwel,~O~ ,,
~ Manufacturer G~~ Material
~ ~ DISTANCE TO: Well Dwelling PERMIT NO.
~ ~ ~ Manufacturer Material Liquid capacity in gallons
~ ~ DISTANCE TO:
~ No. of liTs line , Totallings Trench w~
~ ~of tile to fjnish grade ~ MaterJal beneath tile
~ ~'~ ~ inches Total~~sorption area
m Length Width Depth PERMIT NO.
~ ~ Type of crib Crib diameter Crib depth Total effective absorption area
~ DISTANCE TO: Well Building foundation Nearest lot line
~ Class Depth Driller Distance to lot line PERMIT NO.
~ DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s)
OTHER
SOl L TEST RATING
APP~E~ ~ DATE LEGAL 3
~.,!~. DEPARTMENT OF NATURAL RESOURES
~ ~ Division of Geological 8~ Geophysical Surveys
~ LOCATION OF WELL (Pleaee complete either la lb Drilling Permit No. e
............ , ,*, ur ~.; A.D.L. No.
t~'13'Ch 48 --of--of--of __ ! 9 i 15 r3.~ Seward
I~. JDISTANCE AND DIRECTION FROM ROAD INtERSEcTIONS 3. OWNER OF WELL:
Mr. Bill Sp~k
Addre=~:
$1reet Ad~e=~ and Area ef Well
~, WELL LOG
Feet Belo~
Surface 4. WELL~TH: (final) 5. DATE OF COHPLETIQN,
Maf~rlol Type ~ 0 ~
~)~.t TOp Bottom ~ ft. ~ --
~ Irrigation ~ Recharge ~ Comm~rlcal
~~ ~ Telt Well ~
8. CASING: ~ Threaded
diam. ~ In. to~ ft. Depth Weight
~ ~ . ~.0 ~.~ W,~d,~
~~ dlam.~ln, lo.. ft. Depth Stlckup~ ff.
~UNI~I~LII~' O~ ~,~H~A~ 9. FINISH OF WELL:
E~IEO;~7~ .,U,~[ION ~ -- ~ Type: · Diameter:_
Slot/Mesh Size: -
~ Length :_
udT 2~ i9g2 s., ~.,.... ,,. ~.d ,,.
Backfilling , ~ Grovel Pack _
__ J__V_g~ ,o. sT,T,c w,~, L~V~L,_ ,. _ / /
~ ~ ~Above or ~ Below land lurface Dote
Equipment ueed:
~~ II. PUMPING LEVEL below land surface and YIELD
~ - fl. after ~hrz. pumping g.p.m.
~ ~ ~ff' after ~hr=. pumping~g.p.m'
IZ.GROUTING Well Grouted: ~ Yea ~ No
~ ~ Material: ~ Neat Cement ~ Other:
13. PUMP: (If available) HP
Length of Drop Pipe - ff. capacily g.p.m.
~ ~ Sub.. ~ ~.~ ~ c..,rmc., D o,~..
~~ 14. REMARKS:
16. WATER WELL CONTRACTOR'S CERTIFICATION:
15. Water Temperature ~o ~ F ~ C
Thlt well ~as drilled under m urls
~..~_. ~ ..... Y J diction and this report Is true lo thc, best of my knowledge and belief;
.... ,~-.u~on ~r~z~=nU ~A 53~5
R~gi~t~rld Business Name
:~.O. ~O~ ~0'~ ~at:~ ~Y~!'t ~k. C°nlroct License Number
Address;
Authorized Representative . - ....
Form O2-WWR (11/81} Copy Distribution: WHITE'Stole DGGS, PiNK-Driller, CANARY'Customer
'PERMIT NO.
l"lUli'-,! T r: 'r,,~',~RL T T'T' F,F
[:EPIRRTMENT , HEFlLTH IRND EN, IRONr,IENTIRL' .(OTECTION
825 /L¢ STREET, IRNCHORIRGE, FlK. 99501
264-4720
I.--IELL R1"-.IE:', 01"-4--5 T TE
',' 828642: )
i~:'PLICIRNT NILLIIRM E. SF'URI...'. E:OX 4-1,.-"66 IRNCH.
!OCIRT 101'-4
iEGFlL LOT/48 SEC 9 T15N' ~:114 LOT SIZE
,FYPE OF SOIL IRBSORF'TI01'.4 S'T'STEH I5' DRIRINFIELD
~'IRX]'MUH NUMBER OF BEDROOMS = ~: SOIL RIRTING <SQ FT?BR>=
/THE REOUIRED S~E.~THE SOIL IRBSO::ON SYSTEM IS'
'
/ E:"EF'T .tF-I= ~ "-[--EI'-~GTH= .:, -=.
20000 SQUARE FEET
~3 F.,:' Fi "..,' E L [:-'EPTH= 2
THE LENGTH DII'dENSIOr.4 IS THE LENGTH ,,'IN FEET) OF THE TRENCH CIA DRRINFIELD.
THE [:.,EF'TH OF R TRENCH OR PIT IS THE [:,ISTIRIqCE E:ETI.,4EEr.,I THE SURFACE OF THE
GROUND FIND THE E:OTTOM OF THE EXC:AVRTIOI'.4 ,.'IN FE~
THE TF-:EI"-.~L--:H !...-! T E':,TH T S ',,-':.. E'~OLZ~..~ FEET.
THE 6RIRVEL E:,EF'TH IS THE I'dINIMLII'd DEPTH OF GRFlVEL BETI,IEEr.,I THE OUTFALL PIPE
FIND THE BOTTOM OF THE EXC:FI',/FITICd'~ ,:.'IN FEET). .
REL::..,IJ I F-:ED SEPT T C: T IR !'-,I I-:-'. S I ZE= :2. E~ r"~ ~--'~ 1-3F:tLLC~I'-.IS
F'ERHIT IRPF'LIC:IRNT HAS THE RESPONSIBILITY TO INFORI"I THIS DEF'RRTMENT DURING THE
INSTIRLLIRTION IN=,FE_.TiUNS'- ' r' - OF FtNY 14ELLS FID._TIRCENT TO THIS F'F.:OPERTY FIND THE
NUI'dBER OF RESIDENCES THFtT THE P.!ELL I:IILL SERVE.
TI..-I C~ ,' 2-" ;, T 1"-.~SF"ECT T 6~1"-,1'; F-IF~E REr2..LI T REr'.'.
E;IRCI-(FILLII'..IG OF FINY c ,,- ,
-,~r--,TEI'I 14ITHOUT FINAL INSPECTION AND IRPPROVAL E:Y THIS
[:'EPIRRTt'dEI'-4T 14ILL BE SUE:JECT TO PROSECUT!ON.
I"IlNIML/r,1 DISTANCE BETI,IEEN A ;4ELL IRI'.~C, ANY ON-SITE SENFtGE DISF'OSRL SYSTErt IS
100 FEET FOR IR F'RI',/ATE NELL OR 150 TO 200 FEET FROM A F'I_IE:LIC P-tELL DEPENDING
UPON THE TYF'E OF F'UBLIC NELL
HINIMUM DISTIRI'..ICE FROM Fi F'RIVIRTE HELL TO R F'RIYIRTE SENER LINE IS 25 FEET AND
TO IR COr,1MUNITY SENER LINE IS .75 FEET.
NELL LOG__.'; ARE REg!UIRE[:, IRND MUST E:E RETURNED TO THE DEPIRRTI',IENT 1.4ITHIN ~0 DRYS
OF THE NELL COMPLETION.
OTHER REC..!UIREMENTS I"IIRY FIF'F'LY. SF'ECIFICIRTIONS IRIqD CON~TRUCTInN DIIRGRRMS ARE
RVRILIRBLE TO INSURE PROF'ER INSTIRLLFITION.
F'EF:I--1 I T E::-::I=' 'ir RE'---'; E:.E~3EI'-IE:EF.: _~--: :.1_.. -1'_=_ :=.---:
I CERTIFY THAT
±' I RH FIRMILIRR P~ITH THE RE~!UIRE[.~ENTS FOP, ON-SITE SEL4ERS AND NELLS RS SET
FORTH BY THE MUNIr:IF'RLITY OF RNCHOF.:RGE.
2' I NILL INSTALL THE SYSTEM IN RCCORDRNCE NITH THE CODEC:.
_'2:: I UNDERSTAND THAT THE OH-SITE SEI,.IER rS'T'STEI',I MAY RE.qUIF.:E EIqLAF.:GEf,IENT IF THE
RESIDENCE IS REMODELE[:, TO INCLU[:,E I','IARE THAN _.3: E:EDROOMS.
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
SOILS LOG
[] PERCOLATION
TEST
PERFORMED FOR:
LEGAL DESCR,PT~ON:
~/ 77. /~'~/
SLOPE
4 6L,~Y ........
5
10
11
12
13
14
15-
16
17
18
19
20
No.
DATE PERFORMED: "~['/~'-~'~
-s
I~E PLAN
was GROUND WATER
ENOOUNTERED,
O
IF YES, AT WHAT ,...,/ / E
DEPTH? ' .,.
PERCOLATION RATE //y-~ ""'
(minutes/inch)
Reading Date Gross Net ' Depth to Net
....... Time /~ Water Drop
~. FT
DATE:
Municipality of Anchorage
DeVelopment Services ,,Department"
Building Safety Division
On-Site Water and Wastewater Program
.4700 S6uth Bragaw St.
P.O. Box 196650 Anchorage,~ AK .99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL'
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 051-104-68
GENERAL INFORMATION
Complete legal description T.n ~-
Location (site address or directions)
Expiration Date: ~ -~. ~, _ ~) z_~
ARA · ~,~nnt'~-V~nd~-~nnR q~4.1,~.l e~[OIl
20838 'Relluva St. Chugiak
Current Property owner(s) Joseph
Mailing address ,Juneau,
& Rachelle LawendowskDay phone ., 907-364-4664
AK
e
Lending agency
Mailing address
Real Estate Agent
.Kathi Olmstead
Day phone
Day phone 6q&-/,2nn
Mailing Address 16600 Centerft~lrl Br. ti?.~ll Rna1. ~ver, AW' 99577
TYPE OF WASTEWATER DISPOSAL:
'Individual Omsite ~
Individual Holding tank E]
Community On-site [-I
Public Sewer []
NUMBER OF BEDROOMS: 3
TYPE OF WATER SUPPLY: '
-Individual Well ~
Individual Water Storage " [-'1
Community Class ~ Well [--I
Public Water System []
I
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results. (Certificates may be reissued for a pedod of up to one year with valid water samples.)
Certificates are valid for one year for properties served by Class A or B wells or a public water system. The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
e
STATEMENT OF INSPECTION BY 'ENGINEER
As certified by my seal affixed hereto and as &f the validation date shown below, I verify that my investigation,
beset on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-
site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further vedfy that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation. ' '
Name of Firm S & S En~ineer~nR
Address 17034 N. Eagle River Loop
Engineer's Printed Name. Robert C.
5. DSD SIGNATURE
' l/ Approved'for ..~'
Disapproved. .
Conditional approval for
bedrooms.
Phone 694-2979
Ste. 204 Ea~le River, AK 99577
Date
fj ~ % ROBERT
bedrooms, ~th the follo~ng stipulations: '
Additional Comments
Attachments:
HAA Checklist X
Septic System AdviSory ,
Well Flow Advisory.
Maintenance Agreements
Supplemental Engineer's Report'
Other
Original Certificate Date: ,~-'-.2_.,Q. ~ '-0/7/--
(Rev. 0t/02)
AD
Bo
Municipalit), or AnChorage
Development Services Department
Building Safety Division
' "On-Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
Legal Description:
WELL DATA
Well type
Date c mpleted ~/~ ;Sanitary (Y/N)
Total depth
ft.
HEALTH At,ITHORITY APPROVAL CHECKLIST
Lori4~/~,, ,' ~,¢¢:s V/4¢~6~o¢ ParcellD:
'" ' ' ' ' ' ' ~{9 '
If'A, B, or C provide PWSID # --- :Well Log (Y/N) i Y
FROM WELL LOG
Static water level
Well production
WATER SAMPLE RESULTS:
Coliform O) colonies/100 mi.
SEPTIC/HOLDING TANK DATA
ft. ~
g.p.m.
Wires properly protected (Y/N) ,
i'
Casing height (above ground)
AT INSPECTION
g.p.m.
Nitrate O, I mg./I. Other bacteria.~_O -colonies/100 mi.
Date installed ~"J
Cleanouts (Y/N)
High water alarm (Y/N)
Tank Type/Material, ,~r'l ~,. / ~
Tank size t~-"~gal. Number of Compartments
Foundation cleanout (Y/N) "~/ Depression over tank (Y/N)
Date ,f pumping ~. I "?.--,~./O 4 Pumper, ~'~
ABSORPTION FIELD DATA
Date installed ~ ] J~l O I Soil rating (g.p.d./f¢ or ft'/bdrm) O, ¢
Length ~1 ft. Width J ¢ ft.
Total depth ~ ft; Eft. absorption area~ / ~t~ Monitoring tube,
Fluid depth in absorption field before test ~. in. Water added ~gal.
Elapsed Time: ~Omin. Final fluid depth ~ in. Absorption rate >=
Any rejuvenation treatment (past 12 mo.) (YIN & type) ~¢~ ~d ~ ~ If yes, give date
System type ~
Gravel below pipe ! ~)o ~" ft.
Depression over field
For :2~ bedrooms
D..LIFT STATION
· :;
Date installed
"Pump on" level'
;I
Datum
.f
E;: ~SEPARATION DISTANCES
Size in gallons :I:
"Pump off" level at' in.
Cycles tested :: '.
Manhole/Access Y/N)
High water alarm 'level'
M~ets alarm
& circuit
requirements?
:.'SEPARATION DISTANCES FROM WELL ON LOT TO: "" : ['
'-:.ii ·~! .... lJlot:..:" 0 I':o;if.;.il ;. ; . ,'
i: Septic tank/h on I O_, 1- '+;;i.. . i On ad' acent, lois
. ;~bsorption field or~ I(~t !'i'l / . atn
. Public sewer main /t~ Publi( 'sewer manholelcl~ 5ut
~septic s?~,c, lin ':' "~' . ' H°Iding ,a~
SEPA~TION DISTANCES FROM SEPTIO/H~ TANK oN LOT TO: ,
~uilding foundation ~ Prope'dy line, ~ . ~ Abso~ti~n fiel~''
water main [ ~ "i ,
.... ' e e~i line /:0 ~ Sufiacewater-
~O + On ad acentlots
::! O o. !,-r-
Wel s on adjacent ors /
~EPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: '
Property line '
Water Sermce hne I
Watermain ' ' . , ./:,~"
t I,; : : .,i:i
Driveway, parking/vehicle storage
'~urtain drain ~1~):~,.1'¢- J/~fJ~'~ Wells On id
COMMENTS ' I~i[ ', '
ENGINEER'S CERTIFICatION '. . . ' '
I 'cedify that I have determined through fie/d inspebtions and
rewew of Mun/c/pa/ records ~hat the above systems are m,
~onformance with MOA H,4A:gbideh'nes in'effec't c;n' this date.'
' e II 0,o,~,~- L-. I'LOf"-;/J,'J
Engineers Printed Nam ~ _ , --.'..:,_ _ .
Date ,: t '!f' ;'~-/~ Y'/O ¢. ;:
HAA Fee $ '/i/
Date of Payment
i: ',Recleipt Number
.Waive~ Fee::$
Date 0'f Payment
Rec~eil~t Number
l.herd~y ce~ify th~t I have su~cycd ~he
'. ~,- v~,.l~.,.,,,~' ~ ~,':..'.'" .' ..." '".
....... on the ~per~ ly~
~ ?pmv~em! on pmpe~ lV~ adia~nl t ' . e'.
ez~p~sma~c~e~..' . . . .i, ;.., , . :.~ .:-
D~led ~t F~$~ ~iv~, Alaska "..' ....
I ~':~ '~.~.~,,Lz,~y' "-'-: ..... ~.-~. '.-.
, · .so~r ~.~o~' ~~:'"'-I
I ~*~ · ':- ~,S~,~d [,,~ S~, or ~,.~ ...
1
~ . · .' : ". :: ' r~one (~)_ 69~3. ~':~',.c._ ~." 7"'
47A
29.8
47B
U ~°o~'~"~ !6.,5,.. ~ ~.'
6' C/L FENCE
'7O.0'
o § ~
f I~>1
§1-~1 , *'
o, lzlX
I?1 o= i
I I ~ I1:;;
2~0' BLM EASE
6' WOOD FENCE 6' WOOD FENCE
N O0~Ol'i~3"W 164.89
HELLUVA STREET'
Municipality of Anchorage
Development Services DePartment
Building Safety. DMsion
On-Site Water and Wastewater Pro,ram
.~470OSohth Bragaw St.
P.O. BOX 196650 Anchorage, AK 99519-6650
W~w.~:i.anchorage.ak.us .
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A :SINGLE FA il"YDWELLI'NG
Parcel I.D. 05'/-Io¥-6~
, COi:nplete leg~i d~s'cription
Expiration Date:
· Lot 48A, Brooks Vanderwood Subdivision ,
20838 Helluva Street
Location (site address or directions)
Current Propertyowner(s) Carolyn T.ee
· .Mailinga~ldress ?0 Box 670372,
Lending agency
Day pho.ne 777- 8105
Chugiak., AK 99567:...:.... .... '.
Day phOne
Mailing address
Real Estate Agent
Day phone
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
NUMBER OF BEDROOMS: 3
TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class ~
Public Water System
Well
TYPE OF WASTEWATER DISPOSAL:
[] Individual On-site []
BI Individual Holding tank . E]
BI. Community On-site []
r-] Public Sewer []
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for propedies served by a single family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for propedies served by a private or Class C well and may be reissued with
new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with
valid water samples.) 'Certificates are valid for one year for properties served by Class A or B wells or a public
water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER ' "
"As:(~edified by my seal affixed hereto and as of 'the validation'date shown below, I verify that my inveStig'ation,
based (~n procedures outlined in the Health 'Authority Approval Guidelines for this application, 'show~ ~that the
on-site water supply and/or wastewater dispo'§~l system is(am) safe, functional and adequate for the nt~mber of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation ......
· ~ S & S ENGINEERING" ' Phone
Name of Firm 1707. E*_~!s ~!'.'--r L~cF ~,,.,,4 Ne.
Address E.',gle River, AlasEa 9,577 G/~)..
Engineer's Pi'irited Name RobeZ:t C. Co.an, ?.E. Date'
r .~ ...... "-'/
...... : .....
5. DsD SIGNATURE ~ ' -' '~.,~'.... ..-'.'.~
Approved f°r'i ~ bedrooms. · ~.'~,:~,~' ..... ,.','.,~:" -¢
.. DisapproVed.
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
'Maintenance'Agreements
Supplemental Engineer's Report
Other
Original Certificate Date:
{Re,/. 12J00}
. MUniciPality Anchorage ' r
: !' Develop;ment serVices Department :~ ~
' : i BUildin{] Safety Division" . ~ ~
~ ! ;:: On-siie Water & WasteWater. Program ' I I
· ~ !: 4700 South Bragaw St.
"' : -P.O. Box 196650 Anchorage, AK 99519-6650
[ 'i" "i ;www.ci.anchorage.ak/us
i (907) 343-7904
'[, ~r H LTH A THORITY:APpROvAL CHECKLI,;T
Wel'l type .~__~VA~ ~ If A, B, or'C provide PWSID # ~'- Well Log (Y/N) 4'-
Dat~ ~;o e'i ' ' ' sahi s~]al i Wires prOperly ~rotected~)N)
, t , '~,3 fl: Casing height (above ground)' ·l~ in.
Total depth ~"~ f ft. '-,, Cased to
:I ' '" '!~" FROM WELLLOG 'AT INSPECTION
static watbr ie,~el ft.
W~li Prod g.p.m.
orion .... -~ §.p.m.
s
REsuLT-: ~' . . "[: · ,
WATER
SAMPLE
C~31iform ~i Colonies/100 mi. :Nitr~te l~,·'"~"~::~ng./i, i Other bacter!a -~colomes/100 mi.
- -::' ~ TANK' "DATA .' i 17034 Easle River Loop ~oad No, 204
B SE.P[TICIHOLDING - = --,, .~. ~,
· . ~ . , .... ~' :' [ . :a2~e ,~v.r Alaska 99577
. 'rank ,umber o Compartments ,--' C eanouts ,
Z
High water alarm (Y/N) '~/
Foundation'oleanou~,) ': ~'6' Depress,o? over tank (Y/N) /~ 0 :
Date Installed ~/= ! Soil rating (g.p.d;/ft~ or ft~/bdrrn) ~/~ ~-. System type , .
[}!' ':~" '*~ ' - ~ ' ' ' ' ~
Length . ~ ~/,~ . ff., ~. , Width ~ : ' /~ __--fl. G[avelbelowp~pe ~.~ fl.
Total depth ' ~- i~ff. Eft. absorption'area'-//~fl: Monitoring t~be .~ 'Depression over field
Date ofadeauacv;test . ~ ~ I) . .. ' , ,~ For ,bedrooms
Fluid depth in'absorption field __ in. write? added .gal. i New depth in.
Elapsed Time:i rain...' pth in. * Absorption r,,e >= g.p.d.
An~,~?ejuvenaQ6n treatment, )'(YIN type) L: If yes,
I~,
' : t
ED
Date installed ~.( .in gallons
"Pump on" level at ~. -PUm'p off- level at
Datum : Cycles tested
SEPARATION DISTANCES'
SEPARATION DISTANCES ~R~)M WELL ON LOT TO:
r
Septic tank/~on on lot
Absorption field on lot
Public sewer main ¢'J' '~ '-
eptic service line
in,
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
..On adjacent lots
On adjacent lots
Public sewer manhole/cleanout
Holding tank
I
SEPARATION DISTANCES FROM SEPTIC/~L-DIR~TANK !ON LOT TO:
Building foundation Z:~ '/.4--. : Property line ~ /
-f- Absorption field ~ '~'
Water main /~' i~ ! ~ Water service line ,/O ,/'/- Surface water / OO I,+'
Wells on adjacent lots /OO t,(_ ..
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line ~ O I
~ Building foundation.
Water Servic'e line ! O ~ ,!--
· ~Surface water ! ~
Curtain drain ~f~J/)N~.- ~/~ Wells on adjacent lots ('(20 fr---
COMMENTS
ENGINEER'S CERTIFICATION -
: ~'certify that I have determined through field inspections and
review of Municipal records that the above systems are i.n
conformance with MOA HAA. guidel{nes in effect on th!s date.
/1--
Engineer's Printed Name )/~Jo,~'~7'
Date ::., :. ° /
HAA Fee $' -
Date of Payment
Receipt Number
(Rev. 12/00)
o o 61"-/t,
,Waiver Fee $
Date of Payment
Receipt Number